NDT/RT Film Digitizer User's Manual
Contents
1. MII 800XL Plus User s Manual 3 CE Compliance Statement This device complies with CE Certification pursuant to EN 55022 2006 A1 2007 EN 55024 1998 A1 2001 A2 2003 WEEE Compliance Statement Microtek International Inc operates under full compliance with the WEEE Directive Among the requirements of the Directive are the marking of any applicable equipment placed in the EU market with the WEEE symbol a crossed out wheeled bin as shown at left demonstration of the implementation of a take back program and meeting recycling targets ISO Compliance Statement Comply with the requirements of the international quality standard ISO 9001 2000 and ISO 13485 2003 4 MII 800XL Plus User s Manual Safety Precautions Before using your digitizer read the following safety guides carefully which detail the proper operation of the digitizer and its accessories to prevent injuries or damage to users or equipment Meanings of Symbol Signs This indicates hazardous situation which if not payed CAUTION attention could result injury or damage to users or equipment J This indicates hazardous situation which if not payed WARNING attention could result serious injury or death to users Power Supply A e Use a power source only with a power rating specified on the marking label NA e Ensure to turn off the power of each device before connecting or disconnecting the cables A AN e Insert the plug completely into th
2. 12 x 3 1 3 industrial film use the 12 x 3 1 3 Film Holder which can hold up to three pieces of the 12 x 3 1 3 industrial RT X ray films at a time 1 Place 12 x 3 1 3 Holder on the digitizer glass surface Make sure to orient the film holder with the Microtek logo facing up 2 Place the 12 x 3 1 3 industrial film to be scanned inside the frame of the film holder with the correct side facing up The Grabber is used to remove the film holder out of the scanner glass surface Microtek logo Calibration window Note that the arrow marks on both the film holder and digitizer s top ruler are pointing to each other Important When placing the film holder make sure that the Calibration window on the glass surface is kept clear and free of obstruction at all times MII 800XL Plus User s Manual 25 Scanning Industrial RT X ray films ScanWizard Industry is a scanning software designed by Microtek for X ray films scanning used for an industrial purpose Its user friendly interface enables you to easily start the scanning process and finish all the scan jobs Refer to the ScanWizard Industry software manual for more details 1 Follow the procedures for Positioning Industrial RT X ray Films to place the film holder and industrial film on the digitizer glass surface Launch ScanWizard Industry either as a stand alone by clicking the program icon or by using the File Import or
3. Adjustable Exposure Time By the help of the ScanWizard Industry a scanning software bundled with the MII 800XL Plus users are allowed to adjust the exposure time for film manually This method enhances the visibility of extreme dark film delivering a better scanning result and improving the quality of saved files e Self calibrating The MII 800XL Plus adopts new technology and thus is able to self calibrate every time when the system is powered up minimizing the influence from the storing environment and ensuring optimal scan quality e Energy saving LED light source Adopting LEDs as the light source when the scanner is detected by the system there are no requirements for any warm up time before carrying out the scan which boots your productivity and reduces energy costs amazingly With its stable performance the image quality will remain consistent even after used for a certain period of time e Tremendous Image Quality With a high resolution of 3200 dpi the 16 bit grayscale and a high dynamic range of 4 7 maximum optical density the MII 800XL Plus is able to capture a wide range of gray tones providing excellent details and better visibility when digitizing industrial RT X ray films e Exclusive Film Holders These specially designed industrial film holders are used to hold films in place By loading industrial film holders on the scan bed before scanning film you can ensure perfect alignment of your scanned images
4. Mat 30 MII 800XL Plus User s Manual Take note that there should be no blank areas left around the film or it may cause a poor scanning quality When placing the film and the Black Mat make sure that the Calibration strip on the digitizer glass surface is kept clear and free of obstruction at all times Follow the procedures steps 2 through 9 for Scanning Industrial RT X ray films to launch the ScanWizard Industry software to specify your scanning requirements and to start scanning 24 Microtek ScanWizard Industry M3200 Scanner Overview o E9 Scanner View Correction Help Overview Prescan fi BI O 0 v gt While selecting press CTRL key to keep aspect ratio selection or pre MICROTEK ss SHIFT key to add new job MII 800XL Plus User s Manual 31 Care and Cleaning To ensure optimal performance for the MII 800XL Plus it is important to clean the glass surface of the digitizer on a regular basis Cleaning the Glass Surface 1 Lift up the TMA of the digitizer 2 Use the cleaning cloth come with your package or a soft non abrasive and lint free cloth to gently wipe the glass surface area on the digitizer s flatbed Note Do not use any detergents synthetic cleaning solutions cleaning naphtha or other solvents to clean the glass surface directly 32 MII 800XL Plus User s Manual Maintenance After usage for a period of time the parts inside your
5. Scan command from an application program Click the Overview button to perform a preliminary scan of the image which will appear in the Preview window Select the Scan Frame tool from the Toolbar in the Preview window and choose the area to be scanned by dragging a rectangle around it You will see a flashing frame marquee around the selected area Click the Prescan button to display a detailed image area selected via the Scan Frame tool A thumbnail of the image appears as well in the Scan Job Queue window Select your image output type in the Type drop down menu Select Gray Scale to scan the image in 8 bit grayscale This is also the default Type y Gray Scale setting of the software program Gray Scale 16 bit Select Gray Scale 16 bit to scan the image ny in 16 bit grayscale i L 8 G 05D 9 3 20D 10 gt 3 35D Select your desired image output resolution in the 400 Resolution drop down menu The default setting 800 A P 1600 is 400 dpi If necessary click Darkness to choose a predefined exposure setting for the current scan Untitled J job enhancing the visibility of dark areas Gray Scale x 4 v ppi 0 0635mm If you want to customize an exposure setting for Scan Frame Wi 295 Ht 53 the current scan job choose Adjust from the mage Size 2479 KB Darkness drop down menu and then point your mouse to its edit box Choose a desired setting Adjust 72900 b
6. digitizer such as the light source may become worn out and a problem such as insufficient light supply may occur In this cases contact your local dealers or wholesales for the maintenance services NOTE Your digitizer need a professional to perform the required service or maintenance Do not attend to fix or perform the maintenance by yourself or it may cause dangers to you or the digitizer MII 800XL Plus User s Manual 33 Troubleshooting The green LED on the front panel indicates the status of the digitizer The amber LED beside it stands for power and should always stay on steady when the digitizer is on All On Ready to scan SA READY Indicator Green All Off Scanning or digitizer is off POWER Indicator Amber If you encounter any problems check the section below and follow the suggested solution if your problem is listed You may also want to go over installation steps 1 to 5 as described in the Initial Setup section of this document to make sure that you have followed all procedures properly 1 No light comes on when the digitizer is turned on Make sure your digitizer is connected to your computer and plugged into a power source 2 The Add Remove Hardware Wizard appears on your screen Click the Cancel button and close the ScanWizard Industry Disconnect the Hi Speed USB cable from the back of your computer and refer to the installation instructions in this docum
7. individual frame of the film holder with the correct side facing up The Grabber is used to remove the film holder out of the scanner glass surface Microtek logo f Calibration window Important When placing the film holder make sure that the Calibration window on the glass surface is kept clear and free of obstruction at all times Note that the arrow marks on both the film holder and digitizer s top ruler are pointing to each other MII 800XL Plus User s Manual 23 B Using the 8 5 x 4 5 Film Holder To scan 8 5 x 4 5 industrial film use the paa 8 5 x 4 5 Film Holder which can hold up to three NG pieces of the 8 5 x 4 5 industrial RT X ray films at a time 1 Place 8 5 x 4 5 Film Holder on the digitizer glass surface Make sure to orient the film holder with the Microtek logo facing up 2 Place the 8 5 x 4 5 industrial film to be scanned inside the frame of the film holder with the correct side facing up The Grabber is used to remove the film holder out of the scanner glass surface Microtek logo Calibration window Sy Note that the arrow marks on both the film holder and digitizer s top ruler are pointing to each other Important When placing the film holder make sure that the Calibration window on the glass surface is kept clear and free of obstruction at all times 24 MII 800XL Plus User s Manual C Using the 12 x 3 1 3 Film Holder To scan
8. MICROTEK AAP plus NDT RT Film Digitizer User s Manual Preface 2015 by Microtek International Inc all rights reserved This document may not be reproduced or copied in any way stored electronically or translated into any language without the permission of Microtek International Inc Trademarks Microtek ScanMaker ArtixScan ScanWizard and ColoRescue are trademarks or registered trademarks of Microtek International Inc All other trademarks or registered trademarks are the property of their respective holders Specifications software and hardware bundles are subject to change without notice Not responsible for typographical errors Disclaimer The contents of this manual have been checked carefully for accuracy and every effort has been made to ensure that there are no errors However Microtek makes no guarantee as to the accuracy of the contents of this document and reserves the right to make changes to the contents without prior warning 149 004731 B March 2015 Microtek International Inc No 6 Industry East Road 3 Science Based Industrial Park Hsinchu 30075 Taiwan Tel 886 3 5772155 Fax 886 3 5772598 http www microtek com 2 MII 800XL Plus User s Manual FCC Compliance Statement This equipment Model MMS 6400MU2L has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protectio
9. aasawaaaanasaananananaananannanananan 10 SYSTEM REQUIFEMENTS es vieciseasdeen RAK EDE EE NATA ANAN 10 Taking a Closer Look aaaa GAIN anaa a 11 Front OQpen VIEW comiso mena BRA a HA 11 Rear VIG W iss secinaccartvee aren eeciecns ricasien cuntimsnag beac aaeaxeewena ANDA 12 InitilakSetupi 3a ana AA AERA DAA an 13 Step 1 Unpacking Package Contents cccceceeeeeeeeeeeeeeeeeeenees 13 A Opening the Shipping Carton 424200sasasasaasasasasaasana 13 B Package Contents inns aasa AANI venues aeiaai 15 Step 2 Installing the Software 2 aaaaasaaaakaaa anan 17 Step 3 Unlocking the Digitizer asus aaaanasasaanasananananaananana 18 Step 4 Installing the TMA 2 204042400asasaaaananann naa naa vidiani 19 Step 5 Connecting the Digitizer aaasasaaaanasanaananananaanana 20 Toithe Power Cord maa NAAT 21 To the Hi Speed USB Cable ccccceeeeeeeeeeeeeeeeeeeeeeeeneeaes 21 Digitizing Industrial RT X ray Films Ha 23 Positioning Industrial RT X ray Films ccceee cece cece eee eee eee ee eee eae 23 A Using the 6 5 x 3 5 Film Holder ccccccceeeeeeeeeeeeeeeeneeaes 23 B Using the 8 5 x 4 5 Film Holder cccccceceeceeeeeeeeeeeeeeeeaees 24 C Using the 12 x 3 1 3 Film Holder cccccecceeeeeeeeeeeeeeenees 25 Scanning Industrial RT X ray Films aaaakasasaakasasanaananaanaanananaan 26 Digitizing Industria
10. al Step 4 Installing the TMA 1 Attach the TMA by sliding the posts at the rear of the TMA into the holes 2 Plug the connector of the TMA into the digitizer s 15 pin accessory port MII 800XL Plus User s Manual 19 3 Unlock the TMA a Remove the yellow Unlock sticker from the TMA b Look for the locking knob at the base of the TMA c Turn the locking knob counterclockwise to the unlock position 9 Unlocked NOTE To lock the TMA for shipping and other purposes follow the steps below a Make sure the TMA is connected to the digitizer then turn off the digitizer if your digitizer is on b Turn the digitizer back on The TMA s carriage will move to the standby position in a few moments 2 AN MN NG c When the indicators on the front of your TMA and digitizer stop blinking turn the locking knob clockwise an to the lock position 4 connector from the digitizer The TMA is ready for transport d Turn off your digitizer and disconnect the TMA Locked 20 MII 800XL Plus User s Manual Step 5 Connecting the Digitizer Before connecting the MII 800XL Plus with your computer make sure that the TMA has been properly installed with its connector securely connected to the scanner s 15 pin accessory port If not plug the connector of the TMA into the digitizer s 15 pin acces
11. and achieve consistent scans The MII 800XL Plus provides three types of industrial film holders 6 5 x 3 5 8 5 x 4 5 and 12 x 3 1 3 for scanning industrial RT X ray films e Large size scan bed The flatbed of the MII 800XL Plus lets you easily digitize various sizes of industrial RT X ray films up to 12 x15 9 which offers more flexibility in physical records digitizing e Easy to operate clean and maintain The MII 800XL Plus requires virtually no routine maintenance and no daily cleaning which is ideal for busy radiology departments MIl 800XL Plus User s Manual 9 System Requirements In order to use your MII 800XL Plus your computer must satisfy the following system requirements e CD ROM drive for installing software e Color display with 24 bit color output capability e 4 GB RAM or above e 3 PC or higher with Hi Speed USB USB 2 0 port e Microsoft Windows XP 32Bit Windows 7 64Bit and Windows 8 64Bit 10 MII 800XL Plus User s Manual Taking a Closer Look Front Open View No Names of Parts Functions of Parts 1 Locking Unlocking screw Used to lock and unlock the TMA 2 TMA Transparent Media Adapter is used to scan X ray films 3 Glass Surface Scan bed for scanning X ray films 4 Vertical Ruler Used to measure the length of the images 5 Smart Touch button Scan Press to execute the scan function fast 6 POWER Indicator Amber Indicates the dig
12. e outlet as a loose connection may cause arcing and result in fire Ensure to hold the plug or connector to disconnect the cable otherwise if you pull the cable only it may damage the core wire and result in fire or electric shock A e Place and route the power supply cord such that it is not likely to be walked on or pinched by items placed upon or against them paying particular attention to the cord near the power plugs convenience receptacles and at the point where it exits from the outlet A e When the digitizer is left unattended and unused for long periods of time unplug it from the wall outlet Moving and Storing the Film Digitizer A e Always ensure that the digitizer is stored properly before shipping or moving it Quick stops excessive force and uneven surfaces may cause the product to overturn when moving A AN e Do not hit or drop the digitizer The digitizer may be damaged if it receives a strong jolt which may result in fire or electric shock if the digitizer is used without being repaired J e Do not place the digitizer on any slippery slanted or unstable surface The product may slide or fall causing serious injury to people as well as serious damage to the product MIl 800XL Plus User s Manual 5 A AN e Do not use the digitizer near water Never spill liquid of any kinds on the product or it may result in electric shock or other hazards A e This digitizer should be situated away from heat sou
13. ent 3 When trying to scan an error message appears on your screen that reads Can t Find Digitizers Make sure your digitizer is unlocked see Step 3 and 4 in the Initial Setup section Make sure your digitizer is connected to your computer and plugged in to a power source see Step 5 in the Initial Setup section Uninstall and reinstall the ScanWizard Industry software 4 After clicking scan a blank screen appears Make sure your digitizer is unlocked see Step 3 and 4 in the Initial Setup section Uninstall and reinstall the ScanWizard Industry software 34 MII 800XL Plus User s Manual 5 Having trouble scanning industry films Make sure the TMA Transparency Media Adapter is properly installed with its connector securely connected to the digitizer s 15 pin accessory port Make sure you place the film holder with the loaded film properly on the scan bed Do not block the calibration area as indicated in the Positioning Industry Films section Uninstall and reinstall the ScanWizard Industry software MII 800XL Plus User s Manual 35 Specifications Type Image Sensor Lamp Source Scanning Modes Resolution Dynamic Range Scanning Area Product Life Cycle Interfaces Dimensions L x W x H Weight Voltage Power Consumption Environment Important Desktop flatbed film digitizer CCD Charge Coupled Device LED Grayscale in a single scanning pa
14. er s Manual Scanning Industrial RT X ray Films without Film Holders 1 Place the industrial film to be scanned on the digitizer glass surface Proper positioning of the film on the digitizer is important for getting a correct image Incorrect positioning of film will result in an incorrect image e Ifthe width of the film is larger than the width of the digitizer glass surface align the film against the top corners left and right of the U shaped ruler located at the front of the digitizer When placing the film make sure that the Calibration strip on the digitizer glass surface is kept clear and free of obstruction at all times e Ifthe width or the length of the film is smaller than the width of the digitizer glass surface do not align the film against the U shaped ruler located at the front of the digitizer When placing the film make sure that the Calibration strip on the digitizer glass surface is kept clear and free of obstruction at all imes MII 800XL Plus User s Manual 29 Use the two pieces of 17 x 4 Black Mat to cover the left or right area of the glass surface not used The Black Mat should be placed and aligned tightly against with two sides of the film Placing the 17 x 4 Black Mat Use the 14 x 4 Black Mat to cover the back area of the glass surface not used The Black Mat should be placed and aligned tightly against with the back side of the scanned film Placing the 14 x 4 Black
15. escan image Aerial v RA Total Scan Jobs 1 Job s Scanned MICROTEK While selecting press CTRL key to keep aspect ratio selection or pre ss SHIFT key to add new job MII 800XL Plus User s Manual 27 Digitizing Industrial RT X ray Films without Film Holder If the supplied film holder is not going to be used the MII 800XL Plus also allows you to scan various sizes of industrial RT X ray films up to 12 x 15 9 To do so please use either one of the three Black Mats with the film scanned The Black Mat Light from the TMA and other ambient light during scanning may result in overexposed images The Black Mat is designed to work with films which are not available to be used with the film holders To ensure correct exposure and optimal image quality during scanning the Black Mat should be used to shield unwanted light out MICROTEK MICROTEK MICROTEK 14 x 4 Black Mat 17 x 4 Black Mat x2 Take note of the following before using the Black Mat 1 The Black Mat may become dirty over time and with prolonged use To clean the mat use a white cotton cloth dipped in some water and gently wipe the mat surface This ensures that the Black Mat is in optimal condition at all times 2 A protective film covers the Black Mat during shipping and prevents it from being scratched When peeling the film from the mat be careful not to tear or bend the Black Mat 28 MII 800XL Plus Us
16. he wrapped plastic bags and place them on a flat and stable surface where there is enough space for positioning the CG components Once the digitizer has been placed in a suitable location and is ready to be connected to the computer you are ready to step forward to the an installation of the necessary software and hardware for the digitizer a Ss 8 Pull out the Transparent Media Adapter TMA from the bottom foam support MII 800XL Plus User s Manual 15 B Package Contents After you have unpacked your digitizer package please check for the major components listed below MII 800XL Plus digitizer 6 5 x 3 5 Film Holder lower base Transparent Media Adapter TMA Software CD cS 3x5 8 5 x 4 5 Film Holder Hi Speed USB cable Power cord D 17 x 4 Black Mat x2 14 x 4 Black Mat 12 x 3 1 3 Film Holder 16 MII 800XL Plus User s Manual Step 2 Installing the Software Important Do not remove the yellow stickers from your digitizer until you are told to do so You must install all software before connecting your digitizer Always close any open programs and turn off Anti virus utilities before installing software 1 Turn on your computer 2 Place the MII 800XL Plus CD into your CD ROM drive Ba 3 Follow the on screen instructions to install the driver and software NOTE If the Microtek Software Installer screen does not come up au
17. itizer is on or off 7 READY Indicator Green Indicates the status of the digitizer For more details refer to the Troubleshooting section of this manual 8 U shaped Horizontal Ruler Used to measure the width of the images MII 800XL Plus User s Manual 11 No Rear View Names of Parts Functions of Parts Power Switch Turns the digitizer on or off Power Connector Connects the digitizer to the power cord Hi Speed USB Port Connects the Hi Speed USB USB 2 0 cable to the computer AJ W Nj s 15 pin Accessory port Connects the TMA to the digitizer 12 MII 800XL Plus User s Manual Initial Setup In order to ensure that the digitizer works properly follow the five steps below to set up your digitizer 1 Unpacking the Package Contents 2 Installing the Software 3 Unlocking the Digitizer 4 Installing the TMA 5 Connecting the Digitizer NOTE Before unpacking inspect the shipping carton for any signs of mishandling or damage first The digitizer s packing carton and padding material have been carefully chosen to prevent damage to the unit in shipping and can withstand a reasonable amount of pressure After unpacking your digitizer package refer to the later section to ensure that you received all of the parts necessary for digitizer setup If there are any damaged or missing parts notify the shipper immediately or contact customer service Save
18. l RT X ray Films without Film Holder 28 The Black Mat 2gs AGANG NGINIG NANA ANG 28 Scanning Industrial RT X ray Films without Film Holders 29 MII 800XL Plus User s Manual 7 Care anid Cleaning an AARALIN GD 32 Cleaning the Glass Surface 220 000 0 asasaasananaananananaanananaananannanan 32 Maintenance 232223222322888 ANG NDN AGA 33 IPP ONIX oes coe reteset EDNA ANAN 34 Troubleshooting aaa enan GA NEA NAN detec aE ale were ae 34 SPSCMICATIONS a NGA aia a aa aia a aa dorama wade hela teat 36 8 MII 800XL Plus User s Manual Knowing about Your Film Digitizer The MII 800XL Plus is a film digitizer which is specifically designed for the use of the RT X ray film scanning Features include 16 bit grayscale resolution of 3200 dpi and scanning area of 12 x 15 9 which easily transfer industrial RT X ray films into digital format images The MII 800XL Plus can capture details in bright and dark areas of industrial RT X ray films and provide the professionals a convenient method to digitize the physical originals for the electric data storage saving maintenance time and storage space enormously Features of the MII 800XL Plus e Smart Touch button A Smart Touch button Scan locating at the front panel of the scanner provides you a quick and easy way to capture images that can be automatically saved as files or sent to another application for further processing later e
19. n against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e _ Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Note A shielded Hi Speed USB interface cable with ferrite core installed on the film digitizer connector end must be used with this equipment Caution Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation
20. rces such as radiators heat registers stoves or other products including amplifiers that produce heat A e Do not store the digitizer in which it may be exposed to direct sunlight Using the Digitizer gt e Before using the digitizer make sure the area of the glass surface is clear from obstacles The digitizer is only designed and used for digitizing RT X ray films Do not attend to use it for other purposes gt Maintenance and Service e When the digitizer is going to be cleaned ensure to turn off the power of each device and unplug the power cable from the AC outlet A e When you need a repair service unplug the digitizer from the power outlet and consult qualified service personnel e When replacement parts are required use replacement parts that are specified by the manufacturer or have the same characteristics as the original parts e For safety reasons ensure to inspect the device before using it In addition carrying out a regular inspection at least once a year 6 MII 800XL Plus User s Manual Table of Contents PreTa ea ANAN Aa 2 Safety Regulations 24e sean w KEN NAN NA KAKANAN ANA NNKAKANASANANNKANANASANAKON 3 FCC Compliance Statement KANA NANANABIK NN NANANA 3 Regulation S 4a NANA AA NANANA ANNA ERES 4 Safety PreCauUtiOnsS aaa AABANG ath eeraanaktaennanedes 5 Knowing about Your Film Digitizer 2 aaa 9 Features of the MII 8OOXL Plus 2 2000 a
21. sory port To the Power Cord 1 Connect the power cord to the back side of the digitizer 2 Plug one end of the power cord into a wall outlet or other power source To the Hi Speed USB Cable 3 Connect one end of the Hi Speed USB cable to your computer 4 Connect the other end of the Hi Speed cable to the digitizer s USB port MII 800XL Plus User s Manual 21 5 Turn the Power switch on the back of the digitizer to On and wait for the lights to stop blinking and stay on steady The digitizer will be detected by your system automatically 22 MII 800XL Plus User s Manual Digitizing Industrial RT X ray Films To scan industrial film use the holders included with your package There are three types of holders 6 5 x 3 5 Film Holder 8 5 x 4 5 Film Holder and 12 x 3 1 3 Film Holder Use the holder that correctly matches the film size to be scanned The use of the individual industrial film holder is explained in the succeeding pages of the manual Positioning Industrial RT X ray Films A Using the 6 5 x 3 5 Film Holder To scan 6 5 x 3 5 industrial film use the 6 5 x 3 5 Film Holder which can hold up to three pieces of the 6 5 x 3 5 industrial RT X ray films at atime 1 Place 6 5 x 3 5 Film Holder on the digitizer glass surface Make sure to orient the film holder with the Microtek logo facing up 2 Place the 6 5 x 3 5 industrial film to be scanned inside the
22. ss 16 bit grayscale Approx 65 536 shades of gray 8 bit grayscale Approx 256 shades of gray Optical 3200 dpi H x 6400 dpi V 4 7 Dmax Max Transparent 12 x 15 9 305 mm x 404 mm 100 000 scans or 5 years Hi Speed USB USB 2 0 24 7 x 14 8 x 7 1 627 5 x 375 9 x 180 5 mm 35 4 Ibs 16 1 kg AC 100V to 240V 47 63 Hz 1 5A Max 54 9 W Max Operating temperature 50 to 104 F 10 to 40 C Relative humidity 20 to 85 Storage temperature 14 to 140 F 10 to 60 C Relative humidity 20 to 95 Specifications software bundles and accessories are subject to change without notice Not responsible for typographic errors 36 MII 800XL Plus User s Manual
23. the carton and all packing materials If you need to ship the digitizer later it is recommended that you should repack it using the original wire ties plastic bags foam supports and cartons which protects your digitizer from unnecessary damage Step 1 Unpacking Package Contents A Opening the Shipping Carton After unpacking the shipping carton follow the steps shown below to take out your digitizer and other accessory components 1 Ensure that you put your shipping carton toward the right direction Then open the top cover 2 Remove two cardboards from the top of the shipping carton MII 800XL Plus User s Manual 13 3 Take out the bag containing the film templates on the top of the digitizer Then take out two accessory bags from the insides of two cardboards on each side of the carton 4 Remove each cardboard from four sides D of the carton 5 With both hands hold and lift up two N sides of the foam supports firmly Before S putting down the package on a steady surface do not go off either of hands eS from holding the foam supports NOTE Due to the heavy weight of the digitizer 35 pounds make sure you can handle it properly before removing it from the carton 14 MII 800XL Plus User s Manual 6 Turn over the foam supports and make them stand vertically 7 Lift up the upper foam support sf SS y Then pull out the digitizer 2 1 Finally remove the digitizer from t
24. tomatically double click the following in succession My Computer the CD ROM icon then cdsetup exe to start the installer program 4 To install the software on the MII 800XL PLUS CD click each software program in the order that it appears on the screen to install and follow the on screen instructions 5 Click EXIT on the Microtek Software Installer screen when all the software has been installed 6 Restart your computer MII 800XL Plus User s Manual 17 Step 3 Unlocking the Digitizer 1 Remove the yellow Unlock sticker from your digitizer 2 With the digitizer power off turn the digitizer on its side and locate the locking screw at the bottom of the digitizer 3 Using a screwdriver push and turn a IN the locking screw counterclockwise to the unlock position lll When successfully unlocked the unigcked screw will push out a little protruding slightly from the bottom of the digitizer NOTE To lock the digitizer for shipping and other purposes follow the steps below 1 Turn off the digitizer 2 Turn the digitizer back on When the indicators on the front of your digitizer stop blinking use a screwdriver and then push and turn the locking screw clockwise to the locked position SS When the screw has been tightened this indicates that your v digitizer is locked 3 Turn off your digitizer Locked 18 MII 800XL Plus User s Manu
25. y clicking the left right arrow from its available Halang settings 2 2 15D 3 2 30D 4 245D 5 2 60D 6 2 75D 7a Add to Menu Default 26 MII 800XL Plus User s Manual 9 Click the Scan button on the control panel or the Scan button on the MII 800XL Plus to start scanning Scan Job Queue Thumbnail of If ScanWizard Industry is launched as a stand alone program a window Scan To Save As dialog box will appear Click the Save button then the scanned image can be saved into your selected folder or sent to your selected application To view the scanned image double click the Industry Images icon on your desktop default folder assigned by the software or retrieve it from your assigned folder Microtek ScanWizard Industry Save As Save in Mimass OP Z Image00001 tif T Image00002 tif To Image00003 tif Z Image00004 tif File name mage00005 Save as type TIFF tif 7 Auto filename File prefic Image T Start file 00005 Send image to application after saving a Adobe Photashop If ScanWizard Industry is launched as a Plug In from an application program the scanned image is delivered after the scan to your application where the image can be saved viewed or printed further ppi 0 1270mm H 5 26 Scan Frame Wi 4 00 822 KB Inch w Pr
Download Pdf Manuals
Related Search
Related Contents
Untitled - Lemon Mobiles MANUAL DEL OPERADOR Next 20 (sp-pt-it-de-fr)Descargar Pdf Kombidämpfer 10/1 & 6/1 GN (01702) Nantucket Pavers 31041 Instructions / Assembly ザウルスドライブ 取扱説明書 wachstum durch technologische innovationen Typhoon Easy Mic Compass™SPT™ Compass SPT Limited ダウンロード(pdfファイル/540k) Copyright © All rights reserved.