Solution Ultima 862 Operators Manual
Contents
1. ELECTRONICS DESIGN amp MANUFACTURING Solution Ultima 862 Operators Manual ISSUE 1 00 e gt en Solution Ult ima 862 Operators Manual Copyright O 1998 by Electronics Design and Manufacturing Pty Limited SYDNEY AUSTRALIA Document Part Number 486 DOCUMENT ISSUE 1 00 Printed 16 February 1999 This documentation is provided to suit the Solut ion Ult ima 862 Control Panel CC486 Firmware Revision 1 00 Hardware Revision A F Copyright Notice rights reserved No part of this publication may be reproduced transmitted or stored in a retrieval system in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of Electronics Design and Manufacturing Pty Limited Trademarks Throughout this document trademark names may have been used Rather than put a trademark symbol in every occurrence of a trademark name we state that we are using the names only in an editorial fashion and to the benefit of the trademark owner with no intention of infringement of the trademark Notice of Liability While every precaution has been taken in the preparation of this document neither Electronics Design and Manufacturing Pty Limited nor any of its official representatives shall have any liability to any person or entity with respect to any liability loss or damage caused or alleged to be caused directly or indirectly by the informa
2. 23 Warranty Statement 31 Y Year 2000 Compliance pp 31 Z AT 7 ZEE 30 Electronics Design and Manufacturing Pty Limited Solution Ultima 862 Operators Manual 39 Electronics Design and Manufacturing Pty Limited ISSUE100 DOC Electronics Design amp Manufacturing Pty Limited A Division Of Detection Systems Inc ACN 002 907 271 25 Huntingwood Drive Telephone 61 2 9672 1777 HUNTINGWOOD NSW 2148 Facsimile 61 2 9672 1717 AUSTRALIA Email edm edm com au
3. Solution Ultima 862 Operators Manual 35 Entry Exit Times Entry Timer 1 Exit Time Entry Timer 2 Entry Guard Time Arming Options Single Button Arming Forced Arming Single Button Disarming YES NO Remote Arming Via ygs NO Telephone Automatic Arming Time AM PM Automatic Disarming Time AM PM Output Descriptions Output 1 Output 3 Output 2 Output 4 Isolating Method Standard I solating Code To Isolate Communication Options Back To Base ves Reporting Domestic Reporting ygs NO Domestic Reporting No Of Beeps Other System Information Siren Run Time Minutes Can Your System Be Serviced If Yes Installer s Code By Another Technician Electronics Design and Manufacturing Pty Limited ISSUE100 DOC 36 9 Digit RF User Code ID Numbers Radio User Code 9 ID Number Place RF Radio Keyfob ID Sticker Here Radio User Code 10 ID Number Radio User Code 11 ID Number Radio User Code 12 ID Number 9 Digit RF Device ID Numbers Zone Number RF Device 11D Number Place RF Device ID Sticker Here RF Device 2 ID Number RF Device 3 ID Number RF Device 4 ID Number RF Device 5 ID Number RF Device 6 ID Number RF Device 7 ID Number RF Device 8 ID Number Zone Number Solution Ultima 862 Operators Manual Radio User Code 10 ID Number Radio User Code 14 ID Number Radio User Code 15 ID Number Radio User Code 15 ID Number RF Device 9 ID Number RF Device 10 ID Number RF De
4. button eg 9 User 9 16 User 16 etc Two beeps will be heard and the user number that you just selected will now display on the codepad indicators Enter the 9 digit ID number found on the back of the radio remote hand held transmitter followed by the button Two beeps will be heard and the STAY and AWAY indicators will extinguish If you wish to add or change any further radio remote user codes repeat this procedure as many times as reguired Electronics Design and Manufacturing Pty Limited ISSUE100 DOC 14 Solution Ultima 862 Operators Manual Deleting User Codes Radio User Codes Only the Master Code holder can delete other system user codes How To Delete A User Code 1 Enter your Master Code followed by 1 and the button eg 2580 1 Three beeps will be heard and the STAY and AWAY indicators will begin to flash 2 Enter the user code number 1 16 that you wish to delete followed by the button eg 2 User 2 16 User 16 etc Two beeps will be heard and the user number that you just selected will now display on the codepad indicators 3 Press the button to delete the user code that you have selected Two beeps will be heard and the STAY and AWAY indicators will extinguish If you wish to delete any further user codes repeat this procedure as many times as required Radio Transmitter Operations BUTTON 4 Arm In STAY Mode 1 BUTTON 1 BUTTON 2 BUTTON 1 BUTTON 2 Arm In AWAY Disarm Fro
5. 23 Horn Speaker Test 5 eee eere eee eee eene ea eue eaa eeu Yuan e pua ea eon pua e ema pea ue 23 gt 2 220 0 AE eS ER EUER SEEDS Tenue 23 Strobe Test eR 23 Walk minir 23 Test Hi NE HEH 23 Event 23 c H 24 CODEPAD BUZZER TONE CHANGE e eeess ss ere uaa paene aae eov o spa Year ae nero o prae an aua von 24 REMOTE ARMING VIA TELEPHONE e eeeeeeeeee eese esee osos estes eee saos eee ette nenn Dn nao 24 DOMESTIC DIALLING Rue EE sae REN Ned ua aed 25 Acknowledging Domestic Callls icceccccticccssesesvsescceccsesssosccncccecssesssoscnneceecssesesouseveceecssssesueneaseecssessseeseasevessesesens 25 Programming Domestic Telephone 26 Disable Domestic 2 26 BASIC PAGER REPORTING 27 Basic Pager Display Information scccccsssssssssssssccssssssssssssccsssssssssssscsesssssssssssssccssssssssssssscssssscsssseennes 2
6. Operations 14 S Sealed osc E uy Y ERI 30 Sensor Watch ai YY ede E 20 30 Silent 30 Specifications onde ei gie 31 STAY Indicator 8 STAY Model eie dedu demie 11 30 Entry Guard 11 STAY Mode 24 5 33 12 30 Entry Guard Timer 12 Programming 7 12 Strobe Test 23 System ivesi e nsii 8 20 ISSUE100 DOC Solution Ultima 862 Operators Manual Telco Arm Disarm Sequence 21 Program Telco Arm 21 Program Telco Disarm Sequence 22 Telco Arming Sequence eene 30 Telco Disarm 30 Telephone Line Fail eene 19 Test Report ete te re 23 Testing Bell Test ete e eR 23 Event 23 Horn Speaker 23 Strobe nion Gu Ur TI TRA 23 Report eu ect teet osi 23 Walk Test uin ep RR ERE Bei 23 Transmitter Operations pp 14 U Unsealed ion eR ERI Rete 30 User Code eee hd 30 User Codes Adding rdiet 13 Deleting 14 W Walk Test ectetuer
7. Sequence Option 1 and Telco Disarm Sequence Option 2 Option 1 Telco Arm Sequence This allows you to program the Call Forward Immediate On sequence or Call Forward No Answer sequence that will automatically operate when you arm the system in the AWAY Mode This feature is only available if your telecommunications provider has the call forward option available Note The examples given in this feature are only applicable to Australia Call Forward Immediate On You can redirect calls to anywhere in Australia including mobiles pagers and answering services When Call Forward is turned on your telephone will not ring Call Forward No Answer When your telephone is not answered within 20 seconds this feature redirects all incoming calls to another number anywhere in Australia but you can still make outgoing calls Option 2 Telco Disarm Sequence This allows you to automatically disable the call forward sequence upon disarming the system Digit Required Number To Program Digit Required Number To Program 1 22 4 Second Pause 3 E d Table 8 Telco Arm Disarm Dialling Digits 9 How To Program The Telco Arm Seguence 1 Enter your Master Code followed by 3 and the button eg 2580 3 Three beeps will be heard and the STAY and AWAY indicators will flash 2 Press button 1 followed by the to select the telco arm sequence Three beeps will be heard 3 Enter the call forward sequence that y
8. carried out if you have a Master Code How To Program STAY Mode 2 Zones 1 Enter your Master Code followed by 4 and the button eg 2580 4 Three beeps will be heard and the STAY indicator will begin to flash 2 Enter the zone number that you wish to have automatically isolated followed by the button eg 1 2 Zone 1 2 Zone 2 etc You will notice that the zone you have selected to be automatically isolated in STAY Mode 2 will now flash If you have made a mistake enter the same zone number followed by the button to clear the incorrect zone To select additional zones to be automatically isolated in STAY Mode 2 repeat Step 2 as many times as required 3 Press the ff button when you have selected all zones to be automatically isolated in STAY Mode 2 to exit this mode Two beeps will be heard and the STAY and AWAY indicators will extinguish Electronics Design and Manufacturing Pty Limited Solution Ultima 862 Operators Manual 13 Disarming The System When you enter the premises after the system has been armed in AWAY Mode or if you have armed the system in STAY Mode 1 or STAY Mode 2 you will need to disarm the system to disable detection devices that will activate an alarm If there has been an alarm condition prior to disarming the system a flashing zone indicator will be displayed indicating a previous alarm on that zone How To Disarm The System 1 Enter your user code followed by the button e
9. system can be tailored to meet all requirements quickly and easily Notice To All Owners It is recommended that you test the sirens strobe and zones at weekly intervals Refer to Testing on page 25 for further information ISSUE100 DOC Electronics Design and Manufacturing Pty Limited Solution Ultima 862 Operators Manual 7 Codepad Indicators Soutien Solution 42348678 12345678 STAY MAINS FAULT AWAY E OF A ad Figure 1 5 Eight Zone Figure 2 5 Eight Zone LED Codepad LCD Codepad The codepad is the communications interface between you and your alarm system The codepad allows you to issue commands and offers both visual and audible indications that guide you through the general operation The codepad incorporates numerous indicators There are zone indicators that are used to show the condition of each zone and four others for general status The following pages outline a list of situations and the relevant indicators that will be seen Zone Indicators The zone indicators 1 8 are used to display the status of the zones The following table 1 2 lists the various circumstances that the indicators will display ie Zone Sealed Zone Unsealed Zone Indicator Definition Off Zone Is Sealed Flashing Fast 0 25 Sec On 0 25 Sec Off Zone Is In Alarm Condition 1 3c ONT SC Zone Is Manually Isolated Or Selected To Be Isolated Table 1 Zone Indicator AWAY Indicato
10. the systems AC mains supply is normal or has failed MAINS Indicator Definition Flashing AC Mains Supply Has Failed Table 4 MAINS Indicator Off Indicator Zone Sealed The indicator will display when the system is in the disarmed state and will flash when a zone becomes unsealed during the disarmed state The indicator will stop flashing when all zones are sealed On Indicator Zone In Alarm The indicator will display when the system is armed in AWAY Mode and will flash when an alarm occurs The indicator will reset once a valid user code has been entered Electronics Design and Manufacturing Pty Limited Solution Ultima 862 Operators Manual 9 N FAULT Indicator The FAULT indicator is used to display that the system has detected a system fault Refer to Fault Analysis Mode on page 17 for additional information on system faults Every time a new system fault has been detected eg FAULT indicator flashing the codepad will begin to beep once every minute Pressing the button once will cancel the once a minute beep and acknowledge the fault eg FAULT indicator on steady FAULT Indicator Definition There Is A System Fault That Needs To Be Rectified The System Is Normal There Are No Faults Flashing There Is A System Fault That Needs To Be Acknowledged Table 5 FAULT Indicator Audible Indications In general the audible indicators given out by the codepad buzzer are as follows Audible Indicato
11. whilst you are away Isolating zones is performed by one of two methods Method two is optional and only allows those user codes programmed by your installer to have access to isolate zones Standard Isolating Standard Isolating allows all operators to be able to isolate zones without the need to know a valid user code How To Isolate A Zone 1 Press the button twice to enter the isolating mode Three beeps will be heard and the STAY indicator will flash 2 Enter the zone number 1 8 that you wish to select to isolate followed by the button Eg 1 Zone 1 2 Zone 2 etc As you select each zone to be isolated you will notice that the corresponding zone indicator will begin to flash If you selected an incorrect zone to be isolated enter the incorrect zone number again followed by the button Repeat Step 2 if more than one zone is reguired to be isolated until all zone that are reguired to be isolated have been selected 3 Press the button after you have selected all zones to be isolated Two beeps will be heard and the system will return to the disarmed state Electronics Design and Manufacturing Pty Limited Solution Ultima 862 Operators Manual 17 Code To Isolate The method of code to isolate restricts only those user codes that have the priority level Code To Isolate set to be able to isolate zones Therefore if any user code has this priority level set the method of standard isolating wil
12. will send a test report without causing the sirens to sound Event Memory This function allows you to replay back the last forty events that occurred to the system The event memory history will replay all alarms and arming disarming of the system in AWAY Mode STAY Mode 1 and STAY Mode 2 However the system cannot differentiate between arming the system in STAY Mode 1 or STAY Mode 2 How To Enter Event Memory 1 Enter your Master Code followed by 8 and the button eg 2580 8 Three beeps will be heard The last forty events will display one at a time via the codepad indicators starting from the most recent event beep will be heard as each event is displayed Electronics Design and Manufacturing Pty Limited ISSUE100 DOC 24 Day Alarm Example Solution Ultima 862 Operators Manual Day alarm allows a combination of zones to be monitored during the disarmed state by beeping the codepad buzzer Only your installer can program zones 1 4 to operate for day alarm An example set up of a day alarm could be the front door of a shop that has a pressure mat or electronic beam that customers activate as they enter to and from the shop As the customers walk onto the pressure mat or break the electronic beam the codepad buzzer will beep How To Turn Day Alarm On 1 Hold down button 4 until three beeps are heard Day alarm will now be turned zones programmed for day alarm operation will cause the codepad buzzer to b
13. 7 Subseriber ID Number seed Pe 27 Sx E 27 Systemi 27 GLOSSARY OF TERMS t quee sies uini ba RR TIE 29 WARRANTY STATEMENT n tous dS 31 YEAR 2000 COMPLIANCE eR 31 SPECIBPICA TIONS mc 31 ADVICE TO USERS m 32 NEW ZEALAND TELEPERMIT NOTES wisisvsessecsstescossessvccssescsvsessseesecsceseusssuasveccsesevertesveusevsedeveos 32 INSTALLATION NOTES mM NM 33 6 Solution Ultima 862 Operators Manual Introduction Congratulations on selecting the Solution Ultima 862 control panel to protect you and your property So that you can obtain the most from your unit we suggest that you take the time to read through this manual and familiarise yourself with the numerous outstanding operating features of this system You will notice that in all aspects of planning engineering styling operation convenience and adaptability we have sought to anticipate your every possible requirement Programming simplicity and speed have been some of the major considerations and we believe that our objectives in this area have been more than satisfied This manual will explain all aspects of operating the control panel All system parameters and options are detailed however suitability is left up to the individual Every
14. STAY IndiCatot zu e enero te tet a System Zone Communciation Disarmirng i cece and eee eee Dee cede eee PR EORR Domestic Acknowledging Domestic Calls Disable eei ep eo os Programming Telephone Numbers Duress Alaris eii cein wd FY Cd FWG Dynamic Battery Testing Electronics Design and Manufacturing Pty Limited 37 E 2 19 Entry Delay ass eee eee 29 Entry Guard 11 12 Entry Times s oe eder idee et Ies 29 Event Memory uii ee stoke TR gy cd 23 External Equipment 29 F Fault Analysis e aiuti RR RA EM 17 Determine Fault 17 Fault Descriptions 19 Communciation Fail eee 20 Date and usce 19 E2 Fault ee eee EUR 19 19 Horn Speaket eise eedem 19 LOW Battery s ioter tede idee 19 Low Battery y I gn 19 RE Receiver 19 RF Sensor Watch oie hcec reus 20 Sensor Watch tede there eU TRUE 20 system eee eed hos 19 Tamper 20 Telephone Line Fail ssssseeneeeeeeese eseese seers
15. al 23 Testing There are various functions that allow you to test that your system is operating correctly Horn Speaker Test 1 Hold down button 1 until two beeps heard The horn speaker will sound for two seconds Bell Test 1 Hold down button 2 until two beeps heard The bell output will operate for two seconds Strobe Test 1 Hold down button 3 until three beeps are heard The strobe will now flash 2 Hold down button 3 until two beeps are heard The strobe will now stop flashing Walk Test Mode Walk test mode allows you to test detection devices to ensure that they are operating correctly Every time you test a zone the codepad will sound one long beep and the horn speaker will sound one short beep to indicate that the zone has been activated when testing 1 Enter your Master Code followed by 7 and the button eg 2580 7 Three beeps will be heard and the STAY and AWAY indicators will begin to flash The codepad will beep once every second while the system is in walk test mode 2 Activate all zones that are required to be tested 3 When you have finished testing all zones required press the button to exit this mode Two beeps will be heard and the STAY and AWAY indicators will extinguish The system has now returned to the disarmed state Test Report This feature is only applicable if your system is reporting via the telephone By holding down button 9 until two beeps are heard the system
16. become physically damaged and arrange for its disposal or repair The transmit level from this device is set at a fixed level and because of this there may be circumstances where the performance is less than optimal Before reporting such occurrences as faults please check the line with a standard telepermitted telephone and do not report a fault if the telephone performance is satisfactory This device is equipped with pulse dialling while the Telecom standard is DTMF tone dialling There is no guarantee that Telecom lines will always continue to support pulse dialling Use of dialling when this equipment is connected to the same line as other equipment may give rise to bell tinkle or noise and also cause a false answer condition Should such problems occur the user should NOT contact the Telecom Faults Service This equipment is set up to carry out test calls at pre determined times Such test calls with interrupt any other calls that may be set up on the line at the same time The timing set for such test calls should be discussed with the installer The timing set for test calls from this equipment may be subject to drift If this proves to be inconvenient and your calls are interrupted then the problem of timing should be discussed with the equipment installer The matter should NOT be reported as a fault to Telecom Faults Service This equipment shall not be set up to make automatic calls to the Telecom 111 Emergency Service Thi
17. d the system will remain armed Note If your installer has programmed answering machine bypass you will need to call the control panel twice to make a connection with the system eg Call the telephone number that your control panel is connected to and let the call ring no more than 4 rings and then hang up the telephone Wait a minimum of 8 seconds before you call the control panel back again Electronics Design and Manufacturing Pty Limited Solution Ultima 862 Operators Manual 25 Domestic Dialling Domestic dialling can be used to call your mobile phone or a relative friend in the event that your control panel has activated an alarm Up to three different telephone numbers may be programmed for the control panel to call when alarm occurs Only your installer can set the system to report in the domestic format however the Master Code holder may change the domestic telephone numbers at any time Acknowledging Domestic Calls When an alarm condition occurs the system will call the first telephone number that has been programmed When you answer an incoming call you will hear the system emitting a siren tone followed by a pause and repeat continually for two minutes eg siren tone pause siren tone pause If you do not acknowledge the call from the control panel during a pause between siren tones the control panel will simply hang up after two minutes has expired and call the next telephone number Pressing the button f
18. de lighting etc Up to three separate outputs may be programmed How To Turn An Output 1 Enter your Master Code followed by 5 and the button eg 2580 5 Three beeps will be heard and the STAY and AWAY indicators will begin to flash 2 Enter the output number 1 3 that you wish to turn on followed by the button Three beeps will be heard and the output will now turn on Repeat Step 2 if more than one output is required to be turned on 3 Press the button to exit this function Two beeps will be heard and the STAY and AW AY indicators will extinguish How To Turn An Output Off 1 Enter your Master Code followed by 5 and the button eg 2580 5 Three beeps will be heard and the STAY and AWAY indicators will begin to flash 2 Enter the output number 1 3 that you wish to turn off followed by the button Two beeps will be heard and the output will now turn off Repeat Step 2 if more than one output is required to be turned off 3 Press the button to exit this function Two beeps will be heard and the STAY and AWAY indicators will extinguish Reset Latching Outputs This feature is only applicable if your installer has programmed an output to latch remain on until you acknowledge the event that occurred How To Reset Latching Outputs 1 Hold down button 7 until two beeps are heard The output will now reset Electronics Design and Manufacturing Pty Limited Solution Ultima 862 Operators Manu
19. delayed operation so that you can disarm the system Is any device connected to your system such as detectors codepads and sirens etc Is a situation where your alarm system is permitted to be armed when one or more zones are unsealed When your system is armed and a zone programmed for delay has been violated the delay zone will handover the remaining delay time to a zone programmed as handover The handover zone will not activate an alarm until the remaining delay time has expired A handover zone will act as an instant zone if violated before the delay zone Can be used to remotely operate your system via hand held transmitters Electronics Design and Manufacturing Pty Limited ISSUE100 DOC 30 Solution Ultima 862 Operators Manual Isolating Allows you to manually disable isolate one or more zones before arming the Master Code Monitoring Station Panic Alarm Sealed Sensor Watch Silent Alarm STAY Mode 1 STAY Mode 2 Telco Arm Sequence Telco Disarm Sequence Unsealed User Code Zones 24 Hour Zones ISSUE100 DOC system Is a numerical code used for arming and disarming the system as well as allowing access to functions such as adding and deleting user codes etc Is a secure location where a digital receiver monitors numerous alarm systems and deciphers their alarm transmission reports The operator can then advise the appropriate authorities to take immediate action This type of alarm indica
20. different systems when a number of control panels are reporting to the one pocket pager Basic Pager Display Information Subscriber ID Number This is the identification number of the control panel and can only be programmed by your installer Zone Status The zone status display shows you the status of each zone 1 8 The following table describes what each number means when displayed on the zone status display Number Zone Displayed Description Zone Normal This indicates that the corresponding zone is in the sealed state Alarm This indicates that the corresponding Zone is unsealed and in alarm condition Zone Bypassed This indicates that a system operator has manually isolated the corresponding zone Refer to Isolating Zones on page 16 for information on how to manually isolate a zone s prior to arming the system Zone Trouble This indicates that a zone was left unsealed after the end of exit time Table 10 Zone Status Display Descriptions System Status The system status information is divided up into 4 digits The first digit of the system status display indicates whether the system is armed or disarmed 8 Disarmed 9 Armed The second digit on the system status display indicates which codepad alarm was triggered by the operator 0 2 No Codepad Alarm 1 2 Codepad Panic or Duress Alarm 2 2 Codepad Fire Alarm 3 Codepad Medical Alarm The third digit on the system status display indicates when th
21. e button eg 25804 before the Entry Guard Time For STAY Mode expires the sirens will activate into alarm Only your installer can program this feature Method One How To Arm The System In STAY Mode 1 1 Enter your user code followed by the button eg 2580 Two beeps will be heard and the STAY indicator will display Exit time will now commence counting Any zones that have been programmed to be automatically isolated in STAY Mode 1 will flash until exit time expires At the end of exit time all zones selected to be automatically isolated will extinguish and the codepad will give one short beep Method Two How To Arm The System In STAY Mode 1 1 Hold down the button until two beeps are heard The STAY indicator will display and exit time will now commence counting Any zones that have been programmed to be automatically isolated in STAY Mode 1 will flash until exit time expires At the end of exit time the zone indicators will extinguish and the codepad will give one short beep Electronics Design and Manufacturing Pty Limited ISSUE100 DOC 12 ISSUE100 DOC Solution Ultima 862 Operators Manual Arming In STAY Mode 2 STAY Mode 2 is only used when the perimeter and unused areas of the premises need to be armed to detect any would be intruder from entering the premises and at the same time allowing you to move freely within an area that has been automatically isolated Programming zones to be automatically isolated i
22. e AC mains supply has failed 0 AC Supply is normal 1 AC Supply has failed The fourth digit on the system status display indicates when a system fault has occurred at the control panel 0 2 System Normal There is no faults 1 2 System Fault There is a fault registered by the control panel Electronics Design and Manufacturing Pty Limited ISSUE100 DOC 28 ISSUE100 DOC Solution Ultima 862 Operators Manual Subscriber ID Zone Status System Status Number 1 7 8 678 01200000 9000 Zone Normal 0 Alarm 1 Zone Bypassed 2 Zone Trouble 3 Disarmed 8 Armed 9 Normal 0 Panic Duress 1 Fire Alarm 2 Medical Alarm 3 AC Normal 0 AC Failure 1 System Normal 0 System Fault 1 Figure 4 Basic Pager Display The example above shows that the transmission has come from the control panel that has an ID number of 678 and that zone 2 is in alarm The example also displays that zone 3 has been manually isolated and the system is armed Electronics Design and Manufacturing Pty Limited Solution Ultima 862 Operators Manual 29 Glossary Of Terms Alarm Condition Answering Machine Bypass Armed Automatic Arming Automatic Disarming AWAY Mode Codepad Day Alarm Detectors Disarmed Dynamic Battery Testing Entry Time Entry Delay External Equipment Forced Arming Handover Delay Hand Held Remote Control Is when your alarm
23. e ease eiae a eee veau ae Y re H HUGH 12 Entry Guard Timer For S TAY M Ode 3 2 2 nee Nee e eu uS Net 12 Programming 5 Mode 2 Zohnes a eA ee eee eee eed et 12 DISARMING THE SYSTEM Od Qu ane YO Qu re 13 ADDING USER CODES i eine Yen Y CER ES e Eq YES EYE SEN ENT QR ET UG HS TERI ENS EAE 13 ADDING RADIO REMOTE USER CODES eee ee eene eee ee eee eese etna sooo e eese teet essa esee ee 13 DELETING USER CODES RADIO USER 5 1 1 1 4 14 RADIO TRANSMITTER OPERATIONS eee eee eee enne oo oae eee sese eee en ooo eese teet eaae Posse eee esee eee 14 CODEPAD DURESS GG 15 25 5 15 CODEPAD 555 15 CODEPAD MEDICAL RON PEE PSOE ART Seen p 15 CODEPAD TAMPER ACCESS 1 eee ettet asas esee e esee tesa ases ee eee 15 IB TING ZONE occ 16 1501 5 16 COde 17 FAULTANALYSIS MODE ho
24. eep during the disarmed state when activated How To Turn Day Alarm Off 1 Hold down button 4 until two beeps are heard Day alarm will now be turned off Codepad Buzzer Tone Change Holding down button 8 continuously will change the tone of the codepad buzzer There are fifty different tones to choose from between 1500 Hz 5000 Hz If multiple codepads have been installed each codepad can have a different tone Remote Arming Via Telephone ISSUE100 DOC This feature allows you to arm your system from any remote location via the telephone For obvious security reasons the system cannot be disarmed using this method make use of this feature you will reguire a touch tone telephone Your installer needs to program this feature to operate How To Remotely Arm Your System Via The Telephone 1 Call the telephone number that your control panel is connected to 2 When the control panel answers the incoming call a short jingle will be heard Press the button on the touch tone telephone for 1 3 seconds to arm the system If you hear modem tones when the control panel answers the incoming call this means that the system has been programmed for remote programming functions by your installer Simply wait for a pause between the tones before pressing the button After releasing the button on the touch tone telephone two beeps will be heard to indicate that the system has been armed in AWAY Mode 3 Hang up the telephone an
25. er if you wish to disable the ability to activate the codepad fire alarm or if you wish to have the codepad fire alarm to be silent Codepad Medical Alarm An audible alarm will be activated when both the 7 and 9 buttons on the codepad are pressed simultaneously Contact your installer if you wish to disable the ability to activate the codepad medical alarm or if you wish to have codepad medical alarm to be silent Codepad Tamper Access Denied Codepad tamper restricts the number of times an invalid user code can be used in an attempt to operate the system When the number of incorrect code attempts equals the number programmed by your installer the system will activate an alarm condition and if reporting back to a security monitoring station the system will send an access denied report If you wish the codepads to shutdown and lockout for a period of time 0 150 seconds ask your installer to program this Electronics Design and Manufacturing Pty Limited ISSUE100 DOC 16 Solution Ultima 862 Operators Manual Isolating Zones ISSUE100 DOC Isolating zones allow you to manually disable one or more zones before arming the system Once a zone has been isolated access is allowed into that zone during the armed state without activating an alarm An example when you may require to isolate a zone before arming the system could be when a PIR detector may be false alarming or that you may need to leave a pet inside a particular zone
26. essesseee 19 9 Forced 10 29 19 Hand Held Remote 22 2 002222 29 Handover Delay epos 29 Speaker eoe ede 19 Horn Speaker Test tote 23 I Installation 33 Intt Oductlomio ooo tr Ono 6 ISolatin eee Oe ER et tere etta 30 Isolating Zones Code To Isolate 17 Standard Method eese 16 L LCD Codep d 2 nu y 3 meme he 7 Battery eost dde 19 M MAINS Indicator eere 8 Master Code LLI A LL FFY 30 Medical Alarm 15 Monitoring 5 30 N New Zealand Telepermit 32 O Off Indicator 2 rite Rs 8 eee 8 Outputs Reset Latching Outputs 22 ISSUE100 DOC 38 rece d eei e hee ve 22 P Pager Reporting 27 Panic Alarm 15 30 R Radio User Codes Adding nys oder ioter eem abes 13 Transmitter 14 Remote Arming Via Telephone 24 Reniote Control uni i dud Re ER 29 RE Low ett 19 Receiver Fail nette ete ttt 19 Sensor o e 20 RF Transmitter
27. first telephone number and the second telephone number If there is only one telephone number to be programmed press the button to exit this function Enter all the digits of the second telephone number eg 96721055 You will notice that as each digit is entered the corresponding codepad indicators will display After the last digit of the second telephone number has been programmed press button to exit this function unless a third telephone number is required If there is a third telephone number to be programmed press the 4 button to insert a break between the second telephone number and the third telephone number Disable Domestic Dialling If at any time you wish to cancel domestic dialling eg You are moving house and do not wish the system to continue calling your mobile phone etc you may enter the following sequence 1 Enter you Master Code followed by 2 and the button eg 2580 24 Two beeps will be heard and the STAY and AWAY indicators will begin to flash Press the button followed by 4 and the button eg 4 The STAY and AWAY indicators will now extinguish Electronics Design and Manufacturing Pty Limited Solution Ultima 862 Operators Manual 27 Basic Pager Reporting This feature is only applicable if your system is reporting to a pocket pager Basic pager reporting requires some interpretation of the numbers that appear of the display However it is possible to differentiate between 1000
28. g 25807 Two beeps will be heard Adding User Codes Only the Master Code holder can add or change other system user codes including the Master Code itself Up to eight user codes may be programmed to operate the system How To Add A User Code 1 Enter your Master Code followed by 1 and the button eg 2580 1 Three beeps will be heard and the STAY and AWAY indicators will begin to flash Enter the user code number 1 8 that you wish to add or change followed by the button eg 2 User 2 8 User 8 etc Two beeps will be heard and the user number that you just selected will now display on the codepad indicators Enter the digits required for the new code followed by the button eg If you wish the user code to be 5768 you would enter 57684 Two beeps will be heard and the STAY and AWAY indicators will extinguish If you wish to add or change any further user codes repeat this procedure as many times as reguired Adding Radio Remote User Codes Only the Master Code holder can add or change other system user codes including the Master Code itself Up to eight user codes User Codes 9 16 may be programmed to operate the system How To Add A Radio Remote User Code 1 Enter your Master Code followed by 1 and the button eg 2580 1 Three beeps will be heard and the STAY and AWAY indicators will begin to flash Enter the radio remote user code number 9 16 that you wish to add followed by the
29. l not function How To Isolate A Zone 1 Press the button followed by your user code and the button again to enter the isolating mode eg 2580 Three beeps will be heard and the STAY indicator will flash Enter the zone number 1 8 that you wish to select to isolate followed by the button Eg 1 Zone 1 2 Zone 2 etc As you select each zone to be isolated you will notice that the corresponding zone indicator will begin to flash If you selected an incorrect zone to be isolated enter the incorrect zone number again followed by the button Repeat Step 2 if more than one zone is required to be isolated until all zone that are required to be isolated have been selected Press the button after you have selected all zones to be isolated Two beeps will be heard and the system will return to the disarmed state Fault Analysis Mode If a fault should occur the FAULT or MAINS indicator will flash and the codepad will beep once ever minute If the AC mains supply has failed the MAINS indicator will flash until the AC mains supply has restored Pressing the button once will acknowledge the fault and stop the codepad from beeping once every minute How To Determine The Type Of System Fault To determine all system faults other than the AC mains supply enter fault analysis mode by following the steps outlined below 1 Hold down button 5 until two beeps are heard The FAULT indicator will remain steady a
30. m Arm In AWAY Mes isa Mode AWAY STAY Mode Mode e BUTTON 3 Optional BUTTONS 1 and 2 3 P Both Butt BUTTONS 1 and 2 M Gan dede Press Both Buttons Activate Panic Alarm At Same Time To Activate Panic Alarm ISSUE100 DOC Electronics Design and Manufacturing Pty Limited Solution Ultima 862 Operators Manual 15 Codepad Duress Alarm codepad duress alarm is used as a silent hold up alarm This will only occur when the number 9 is added to the end of any valid user code that us being used to disarm the system eg 2580 977 duress alarm is only useful if your system is reporting back to a monitoring station or pocket pager as domestic reporting ie mobile phone etc can t decipher which type of alarm had occurred Solution 123456 78 STAY MAINS FAULT AWAY L panic 3 4 L5 L 7 Cel Le L MEDICAL Es O 5 L panic 3 Figure 3 CP5 LED Codepad Showing Audible Alarm Buttons Codepad Panic Alarm An audible alarm will be activated when both the 1 and 3 buttons or both the and buttons are pressed simultaneously Contact your installer if you wish to disable the ability to activate the codepad panic alarm or if you wish to have the codepad panic alarm to be silent Codepad Fire Alarm A distinct fire sound is emitted via the horn speaker when both the 4 and 6 buttons on the codepad are pressed simultaneously Contact your install
31. ming the system include gt AWAY Mode Arms the entire system Refer to Arming In AWAY Mode on page 10 gt STAY Mode 1 Arms all zones except those programmed to be automatically isolated by the installer Refer to Arming In STAY Mode 1 on page 11 gt STAY Mode 2 Arms all zones except those programmed to be automatically isolated by the Master Code holder Refer to Arming In STAY Mode 2 on page 12 Forced Arming The feature of arming the system when a zone is not sealed is known as forced arming If the system does not arm and a long beep is heard forced arming is not permitted If this is the case you must ensure that all zones are sealed or manually isolated before you can arm the system Arming In AWAY Mode When you leave your premises and require all zones to be in a ready state to detect intrusion you would arm the system in AWAY Mode There are two different methods for arming the system in AWAY Mode Method one is standard and will always operate Method two is optional and may be disabled by your installer if you do not wish to use single button arming Method One How To Arm The System In AWAY Mode 1 Enter your user code followed by the button eg 25804 Two beeps will be heard and the AWAY indicator will display Exit time will now commence counting Method Two ISSUE100 DOC How To Arm The System In AWAY Mode 1 Hold down the button until two beeps are heard The AWAY indicator will display and e
32. n STAY Mode 2 can be programmed by any Master Code holder Entry Guard Timer For STAY Mode When arming the system in STAY Mode 2 an optional entry timer called Entry Guard Timer For STAY Mode may be used to delay the sirens if a zone that has not been automatically isolated has triggered into alarm condition Entry Guard Timer For STAY Mode is the delay time used for all zones except 24 hour zones when the system is armed in STAY Mode 1 or STAY Mode 2 If the Entry Guard Timer For STAY Mode has been programmed and a zone that has not been automatically isolated has triggered the codepad will beep twice a second until the Entry Guard Timer For STAY Mode has expired or the system has been disarmed If the alarm condition has not been reset by entering your user code followed by the t button eg 25804 before the Entry Guard Time For STAY Mode expires the sirens will activate into alarm Only your installer can program this option How To Arm The System In STAY Mode 2 1 Hold down the 0 button until two beeps are heard The STAY indicator will display and exit time will now commence counting Any zones that have been programmed to be automatically isolated in STAY Mode 2 will flash until exit time expires At the end of exit time all zones selected to be automatically isolated will extinguish and the codepad will give one short beep Programming STAY Mode 2 Zones Programming zones to be automatically isolated in STAY Mode 2 can only be
33. nd the STAY and AWAY indicators will flash in unison with each other Any zone indicators displayed indicate the type of fault that has occurred Refer to Table 7 Fault Indicators on page 18 for the list of different system faults that may occur To further determine the type of fault condition you will need to hold down the button that corresponds to the zone indicator displayed To exit fault analysis mode and return to the disarmed state press the button The FAULT indicator will remain displayed and the codepad will cease its once a minute beep Electronics Design and Manufacturing Pty Limited ISSUE100 DOC 18 Solution Ultima 862 Operators Manual Zone Fault Hold Down Zone Fault Indicator Description Button Indicator Condition System Fault 3 RF Receiver Fail Horn Speaker 214 Telephone Line Fail A 44 Fuse Fail 7 RF Low Battery Zones 8 RF Low Battery Zone Tamper Alarm Zones 1 8 Tamper Alarm E we d Sensor Watch Fault Aj Zones 1 8 Sensor Watch ee Fail RF Sensor Watch 1 8 Zones 1 8 RF Sensor Watch LL LL Fail 6 1 6 Communication Fail Receiver 1 Fail _ _ _ O Receiver Fail Table 7 Fault Indicators ISSUE100 DOC Electronics Design and Manufacturing Pty Limited Solution Ultima 862 Operators Manual 19 Fault Descriptions 1 System Fault A system fault will only display when any of the following faults occur After ente
34. or 1 3 seconds during the pause will acknowledge the call and no further calls will be made for that event If the call has been successfully acknowledged a tone of decreasing pitch will be heard Digit Required Number To Program Digit Required Number To Program Table 9 Domestic Dialling Telephone Digits Electronics Design and Manufacturing Pty Limited ISSUE100 DOC 26 ISSUE100 DOC Solution Ultima 862 Operators Manual Programming Domestic Telephone Numbers If your system has been set up for domestic dialling this function allows any Master Code holder to program telephone numbers that the control panel will call in the event of an alarm How To Program Telephone Numbers 1 Enter your Master Code followed by 2 and the button eg 2580 2 Three beeps will be heard and the STAY and AWAY indicators will begin to flash If there are telephone numbers already programmed they will be displayed one digit at a time via the codepad indicators If there are no telephone numbers programmed a further two beeps will be heard after entering this mode These two beeps are normally heard after the last digit of the last telephone number has been displayed Enter all digits for the first telephone number eg 96721717 You will notice that as each digit is entered the corresponding codepad indicators will display If there is more than one telephone number to be programmed press 4 This will insert a break between the
35. ou require eg 61 Phone Number if you wish to program the call forward no answer sequence or 21 Phone Number if you wish to program the call forward immediate seguence Remember that when you program a in the telco arm seguence you enter 1 and when you program a in the telco arm sequence you enter 2 4 Press the button when finished Two beeps will be heard and the STAY and AWAY indicators will extinguish Electronics Design and Manufacturing Pty Limited ISSUE100 DOC 22 Solution Ultima 862 Operators Manual How To Program The Telco Disarm Sequence 1 Enter your Master Code followed by 3 and the button eg 2580 3 Three beeps will be heard and the STAY and AWAY indicators will flash 2 Press button 2 followed by the button to select the telco disarm sequence Three beeps will be heard 3 Enter the call forward disable sequence that you require eg 61 if you wish to disable the no answer call forward sequence 21 if you wish to disable the call forward immediate sequence Remember that when you program a in the telco disarm sequence you enter 2 4 Press the button when finished Two beeps will be heard and the STAY and AWAY indicators will extinguish Turning Outputs On Off ISSUE100 DOC This feature is only applicable if your installer has set up an output that can be turned on or off via the codepad The output programmed by your installer could control a pool pump or outsi
36. products that incorporate time keeping functions employ a rotating 100 year calendar This means that Solution products do not use the century in any time keeping algorithms only the year within the century Specifications Temperature Range Humidity Power Source Stand By Current Current Draw In Alarm Condition Current Draw In Alarm Condition With Codepad Back Up Battery Dimensions Case Weight Supplier Code New Zealand Telepermit Malaysia Approval Number Electronics Design and Manufacturing Pty Limited 0 45 Degrees Celsius 1096 95 TFOOS Plug Pack 240 Volt 18 Volt AC 1 3 Amp 65 mA 115 mA 105 mA 6Ah 12 Volt DC Rechargeable Sealed Lead Acid Battery 306 mm x 262 mm x 84 mm Packed In Carton 2 5 Kg N771 PTC 211 98 084 Pending ISSUE100 DOC 32 Solution Ultima 862 Operators Manual Advice To Users The Austel permit that has been issued for this product is subject to the following conditions The Solution Ultima 862 control panel may only be powered by EDM 008 plug pack Approval Number Q92128 New Zealand Telepermit Notes ISSUE100 DOC The grant of a telepermit for a device in no way indicates Telecom acceptance of responsibility for the correct operation of that device under all operating conditions This equipment shall not be used in any manner that could constitute a nuisance to other telecom customers Immediately disconnect this equipment should it
37. r The AWAY indicator is used to display that the system is armed in AWAY Mode The AWAY indicator will also flash in unison with the STAY indicator when programming various options throughout the operator s manual Refer to page 10 for information on the different methods of arming the system in AWAY Mode AWAY Indicator Definition System Is Armed In AWAY Mode 0f System Is Not Armed In AWAY Mode Table 2 AWAY Indicator Electronics Design and Manufacturing Pty Limited ISSUE100 DOC 2 ISSUE100 DOC Solution Ultima 862 Operators Manual STAY Indicator The STAY indicator is used to display that the system is armed in STAY Mode 1 or STAY Mode 2 The STAY indicator will also flash in unison with the AWAY indicator when programming various options throughout the operator s manual Refer to page 11 for information on the different methods of arming in STAY Mode 1 For information and the method of arming in STAY Mode 2 refer to page 12 STAY Indicator Definition System Is Armed In STAY Mode 1 Or STAY Mode 2 Off System Is Not Armed In STAY Mode 1 Or STAY Mode 2 Flashing Once Every pay Alarm Status Day Alarm Turned On 3 Seconds Flashing Twice A Second Zone Isolating Mode Or Setting STAY Mode 2 Zones Table 3 STAY Indicator System Disarmed This indicator will display with the indicator when the system has been disarmed MAINS Indicator The MAINS indicator is used to display that
38. r Definition Once Short Bee A Button Has Been Pressed On The Codepad Or End Of Exit p Time When Armed In STAY Mode 1 Or STAY Mode 2 Two Short Beeps The System Has Accepted Your Code Three Short Beeps The Reguested Function Has Been Executed Onen Bee Indicates the End Of Exit Time When Armed In AWAY 8 p Mode Or The Reguested Operation Has Been Denied Or Aborted Walk Test Mode Is Currently Active Or Warning Before One Beep PT Bend Automatic Arming Takes Place Every There Is A System Fault Waiting To Be Acknowledged Table 6 Audible Indicators Electronics Design and Manufacturing Pty Limited ISSUE100 DOC 10 Solution Ultima 862 Operators Manual Arming The System There are several different ways to arm the system depending on whether you are leaving the premises and require all active zones to be in a ready state for an intruder or if you are remaining in the premises and only require part of the system to be in a ready state for an intruder If a zone is not sealed at the end of exit time the zone will be automatically isolated and will be constantly displayed on the remote codepad The zone will again become an active part of the system when the zone has resealed ie If a window is left open after exit time has expired the window will not be an active part of the system until the window has closed Opening the window after exit time has expired will cause an alarm condition The different methods for ar
39. ra ento enano verto evo e oan edere vea epe NW 17 Fault asl UI 19 System HAUL Ge eu Gu pP 19 LOW Battery GHA NR HR CRT RF NY 19 3 RE 19 WR HAW END SE ERE EERE SEE 19 Horm Speaker ean xn An xn ASA AR NI cine die ien aS 19 Telephone Line 19 19 RN 19 RE Low du Tud Tu FUN TAI A FFAN NAF FFO te teinte nineties 19 tTamper 55e Wi Y nus 20 sensor Watch 20 20 Communication ans sv ex ov ev aer cx ue LM NN Y YN 20 DATE AND TIME 20 5 gt 55559 aH qua epa 21 TURNING OUTPUTS ON OEF 22 Reset Latching certet reete aenea O Y RR va rone ea aUe Era eese a acean e eee 22 APRESS M Df eser FN
40. ring fault analysis mode holding down button 1 will determine which of the following faults have occurred Low Battery A low battery fault will register when the system detects a low capacity back up battery The system automatically performs a battery test every 4 hours and also every time you arm the system Date and Time The date and time fault will register every time the system has been powered down This type of fault will not cause the FAULT indicator to display on the codepad unless your installer has programmed the automatic arming time To program the date and time refer to page 20 RF Receiver Fail The RF receiver fault will register once the system has detected that the wireless receiver unit has been disconnected Horn Speaker This fault will register when the system detects that the horn speaker has been disconnected This fault will clear once the horn speaker has been reconnected Your installer will need to program the system for this feature to operate Telephone Line Fail A telephone line fault will register when the system detects that the telephone line has been disconnected from the control panel Your installer will need to program the system for this feature to operate E2 Fault An E2 fault will register when the system detects an internal checksum error Contact your installer as soon as this fault is displayed Fuse Fail This fault will occur when either of the two 1 Amp fuses has blown Contac
41. s equipment should not be used under any circumstances that may constitute a nuisance to other Telecom customers In the event of any problem with this device the systems battery AC mains supply and telephone line should be disconnected The user is to then arrange with the supplier of the device to make the necessary repairs Should the matter be reported to Telecom as a wiring fault and the fault be proven to be due to this product a call out charge will be incurred Electronics Design and Manufacturing Pty Limited Solution Ultima 862 Operators Manual 33 Installation Notes Installation Company Technicians Name Technicians Telephone Number Installation Date Warranty Expires Panel Software Version Service Notes Electronics Design and Manufacturing Pty Limited ISSUE100 DOC 34 Solution Ultima 862 Operators Manual Zone Descriptions This allows you to describe each zone and tick which zones have been programmed to be automatically isolated in STAY Mode 1 or have been programmed for day alarm operation Isolated In STAY Alarm Mode 1 Enabled Zone 1 Zone 2 LI Zone 3 LI Zone 4 LI Zone 5 LI Zone 6 LI Zone 7 Zone 8 User Code Names Master Code User 5005 User Code 9 User a User Code 10 User on User Code 11 User User Code 12 User pade User Code 13 User User Code 14 User gous E User Code 15 User a User Code 16 ISSUE100 DOC Electronics Design and Manufacturing Pty Limited
42. system is armed and one of the detection devices have been violated A 24 hour zone eg smoke detector can activate an alarm condition when your system is armed or disarmed Answering machine bypass has been incorporated so that it is possible to make a connection with the system for remote arming operations when there is an answering machine or facsimile machine on the same telephone line When the system is in a ready state to accept alarms This feature allows the system to automatically arm at the same time every day in AWAY Mode or STAY Mode 1 This feature allows the system to automatically disarm at the same time every day This is the mode used to arm your system when you leave your premises The codepad allows you to perform all functions such as arming disarming and carrying out functions such as adding and deleting system user codes This feature allows a combination of zones to be monitored while the system is disarmed Are devices connected to your alarm system used to detect intrusion and cause an alarm condition Some forms of detection devices include PIR Passive Infrared Smoke detectors photoelectric beams reed switches and vibration sensors Is when your system is in a state that will not accept alarms except on zones programmed for 24 hour operation Is a feature that is used to monitor and test the condition of your back up battery Is the time allowed after entering your premises via a zone programmed for
43. t your installer as soon as this fault is displayed 2 RF Low Battery This fault will occur when any of the RF wireless devices has reported a low battery condition to the control panel Whilst you are in fault analysis mode holding down button 2 until two beeps are heard will display which zone has reported the RF Low Battery fault Electronics Design and Manufacturing Pty Limited ISSUE100 DOC 20 Solution Ultima 862 Operators Manual Tamper Fail This fault will occur when any zone has become open circuit By holding down button 3 until two beeps are heard in fault analysis mode will display which zone has reported the tamper fail fault Sensor Watch Fault A sensor watch fault will register because one or more detection devices has failed to detect any movement during the disarmed state for the time period programmed by your installer The fault will clear once the zone in question has detected movement and reset Whilst you are in fault analysis mode holding down button 4 until two beeps are heard will display which zone reported the sensor watch fault Sensor Watch Fault An RF sensor watch fault will register because one or more RF detection devices has failed to communicate to the RF radio receiver for the time period programmed by your installer The fault will clear once the RF device in question has successfully transmitted to the RF radio receiver Whilst you are in fault analysis mode holding down button 5
44. tes to the monitoring station that there is an emergency situation at your premises Refers to zone status If a zone is sealed the detection device 15 not violated and the zone indicator will not be displayed on the codepad Sensor watch gives the control panel the ability to recognise that detection devices may have stopped working or that the view to a PIR detector has been blocked thus unable to detect any movement over the duration of the time programmed by your installer Your installer may program zones for silent operation This means that when the zone programmed for silent operation has been violated during the armed period your alarm system will communicate with the monitoring station without sounding the sirens Is a condition that automatically isolates zones when your system is armed in STAY Mode 1 Only your installer can program zones to be isolated automatically in STAY Mode 1 Is a condition that automatically isolates zone when your system is armed in STAY Mode 2 Only the Master Code holder can program zones to be isolated automatically in STAY Mode 2 Telco arming is a feature that automatically calls the telephone exchange and diverts your telephone number to another telephone when the system is armed in AWAY Mode In Australia this feature is called Call Forward Telco disarming automatically calls the telephone exchange and un diverts your telephone number Refers to zone status A zone is unsealed when a
45. tion contained in this book Electronics Design and Manufacturing Pty Limited reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement Table Of Contents 85 6 5 5 ODAU CU 7 ZONE 0 8 1 lt E YhNYNnE Yn 7 LS P Sei e 7 STAY Indicator 8 System DISAFIME E 8 MAINS nieimagece e 8 ordini WA DIE iie M 8 On Indicator Zone In 1armmn Re 8 FAULT Indicator Pn 9 Audible Indications Y 9 ARMING THE 55 ee cactus ences 10 Poeni seis 10 Arming MOUe 10 Armine In STA Y Model oe oper Pose ve ro e o roro voee ge Page o ro nero rege a Te ee 0 eo no rege Va eet onore 11 Entry Guard Timer For STAY Mode 11 Arming In STAY Mode 2 ere r orae naa e
46. until two beeps are heard will display which RF detection device reported the RF sensor watch fault Communication Fail A communication fail will register when the control panel failed to communicate with the receiving party eg monitoring company mobile phone or pocket pager etc The communication fault will clear once the control panel has successfully reported to the receiving party Date and Time ISSUE100 DOC Programming the date and time is only required when you need functions such as automatic test reports automatic arming and history events to operate correctly How To Program The Date and Time 1 Enter your Master Code followed by 6 and the button eg 2580 64 Three beeps will be heard and the STAY and AWAY indicators will begin to flash 2 Enter day month year hour and minute using DD MM YY HH MM format ie DD Day of the month MM Month of the year YY Current year HH Hour of the day MM Minute of the day Please note that when programming the hour of the day you will need to use 24 00 hour format 3 Press the button to exit and return to the disarmed state Two beeps will be heard and the STAY and AWAY indicators will extinguish If a long beeps is heard an error was made when entering the date and time Electronics Design and Manufacturing Pty Limited Solution Ultima 862 Operators Manual 21 Telco Arm Disarm Sequence This feature allows you to program the Telco Arm
47. vice 11 10 Number RF Device 12 ID Number RF Device 13 ID Number RF Device 14 ID Number RF Device 15 ID Number RF Device 16 ID Number ISSUE100 DOC Electronics Design and Manufacturing Pty Limited Solution Ultima 862 Operators Manual Index 24 Hour 7 98 Access Deried s oeste eiit Adding User Adyice To USersn dub e ddd t Alarm Answering Machine Bypass pp ATIBDed iecit ed tr AMET ATINS casio AWAY Mode eedem e Forced Arming STAY YT Y S TAY 2 niii het He Telephone Audible Automatic Automatic AWAY Indicator AWAY Mode tere ene eere 10 Basic TR RES Bell tea Fm CGC SY Codepad niit tete e peius 7 Buzzer TONE oie ate reete en Duress Al rti tette e eie ben Medical Pantie Alaris ete ee Tamper ertet tein Codepad Indicators Audible Indications eee AW AY 4 FAULT Indicator MAINS Off Indicator Gu eec eec On IndicatobP een uu to ote eo om dee o
48. xit time will commence counting Electronics Design and Manufacturing Pty Limited Solution Ultima 862 Operators Manual 11 Arming In STAY Mode 1 STAY Mode 1 is only used when the perimeter and unused areas of the premises need to be armed to detect any would be intruder from entering the premises and at the same time allowing you to move freely within an area that has been automatically isolated Programming zones to be automatically isolated in STAY Mode 1 can only be programmed by your installer There are two different methods for arming the system in STAY Mode 1 Method one is standard and will always operate Method two is optional and may be disabled by your installer if you do not wish to use single button arming Entry Guard Timer For STAY Mode When arming the system in STAY Mode 1 an optional entry timer called Entry Guard Timer For STAY Mode may be used to delay the sirens if a zone that has not been automatically isolated has triggered into alarm condition Entry Guard Timer For STAY Mode is the delay time used for all zones except 24 hour zones when the system is armed in STAY Mode 1 or STAY Mode 2 If the Entry Guard Timer For STAY Mode has been programmed and a zone that has not been automatically isolated has triggered the codepad will beep twice a second until the Entry Guard Timer For STAY Mode has expired or the system has been disarmed If the alarm condition has not been reset by entering your user code followed by th
49. zone has been violated The corresponding zone indicator will display on the codepad A user code is the personal identification number that the operator uses to arm and disarm the system A monitored input used to trigger an alarm condition when violated A monitored input programmed to trigger an alarm condition when violated when the system is armed or disarmed 24 hours a day Electronics Design and Manufacturing Pty Limited Solution Ultima 862 Operators Manual Warranty Statement 31 Electronics Design and Manufacturing Pty Limited warrants this product to be free from defects in material and workmanship for a period of three years from the date of manufacture as indicated by the date stamp and or serial number on the product Defective units returned by the purchaser at their own expense during this period will be repaired or replaced at the option of the manufacturer The repair or replacement will be free of charge provided that the defects were not incurred during shipping or handling or the damage was not due to causes beyond the control of Electronics Design and Manufacturing Pty Limited such as lightning excessive voltage mechanical shock or damage arising out of abuse alteration or improper application of the equipment Year 2000 Compliance This notice is to confirm that all Solution Ultima 862 control panels are not susceptible to or can be corrupted by the Year 2000 Millennium Bug To date all Solution
Download Pdf Manuals
Related Search
Related Contents
GAMME CONSTRUCEP SEAT BELTS - Textfiles.com Well Traveled Living 60354 User's Manual V7 TD23BLK-PL Logiciels de création et de gestion de thesaurus/note de Guide d`installation du Power-Pipe kit del motociclista sicuro UCT μT-Kernel DevKit tuned for Kinetis Fantec I-STAR TC-500R8A Targus Privacy filter wide screen 15.2" Copyright © All rights reserved.