1. at 1 second Setting are as follows Button 1 1 second Button 2 5 seconds Button 3 10 seconds Button 4 15 seconds Use only pre learned Microlatch keyfobs Press the LEARN DELETE switch twice within 4 seconds The LED will then remain steady on no flashing meaning the receiver is now in Timing mode Press the learned fob twice to set timing of each relay NB Button 1 corresponds to relay 1 Button 2 corresponds to relay 2 Button 3 corresponds to relay 3 amp Button 4 corresponds to relay 4 1 The button pressed first designates the corresponding relay to be timed 2 The button pressed second defines the timing to the selected relay For example if you want relay 2 set at 10seconds then on the first press select button 2 relay 2 and on second press select button 3 timing for 10 seconds 3 Please do not press the buttons too quickly and wait for about one second for next press between the two presses The LED will flash once after pressing the button to indicate a successful learning Press the LEARN DELETE switch once again to exit the timing setting mode If you forget to exit timing setting mode LED remains steady on the receiver will do so automatically after 18 seconds of no activity Master Fob The first learned fob will be defined as the Master Fob This is a useful feature in that new fobs can be learnt without having to physically press the LEARN DELETE on the REC14 circuit board To learn a new fob press buttons one
2. 1 and two 2 of Master Fob together at the same time Rec 14 LED will flash quickly for approximately 10 seconds indicating the device is in learning mode To learn a new fob simply press any button on the fob The device will automatically exit learning mode after 10 seconds Deleting Fobs and Reset Timings Press and Hold the Learn Delete switch The LED will come on When the LED extinguishes approx 5 seconds all codes stored in the EEPROM memory will be erased and all the timings will be reset to approximately1 second The LED will give a flash to indicate the successful erasure Relay Setup Each of the four relays can operate as either momentary operates whilst a transmission is received or latching changes state with each transmission The 4 way DIP switch is used to set operation With the switch corresponding to the relay set to the ON position the relay will LATCH With the switch in the OFF position default the relay will operate in momentary mode Power The REC 14 is designed to operate from 9 to 24VDC and 9 to 24VAC The on board transistor regulator will get quite WARM when operating in latched mode at 24VAC DC This is normal DO NOT REMOVE THE HEATSINK
3. Overview The REC 14 is a general purpose UHF receiver operating on 315MHz 433MHz and 868MHz Four single pole double throw SPDT outputs are available to control external devices The receiver is designed for use with Microlatch 1 2 or 4 channel keyfobs or Microlatch BIO XX fingerprint readers This system uses code hopping technology for secure RF transmissions The REC 14IP65 version of the product is supplied in an IP65 rated ABS plastic enclosure which allows installation of the receiver in an external environment with water resistance Cable entry is via a cable gland at the bottom of the case The antenna is weatherproof and detachable Installation Tips for Best Performance To ensure best performance from this product DO NOT install the receiver on or next to a metallic surface If this is unavoidable then the antenna will need to be brought clear of the metal via a coaxial cable The remote Antenna BNC ANT 01 connector should be wrapped in self amalgamating tape or the internal pin coated with silicone grease if installed near SALT WATER If range is poor and interference from another source has been eliminated try moving or re orientating the receiver Specifications Operating Voltage Current Consumption 12VDC 24VDC 16VAC Physical Dimensions Case Material Output Channels Output Ratings Reverse Polarity Protection RF Operating Frequency RF Signal Type Data Transfer Coding Combinations Learning Capacity RF De
4. ff Push the antenna wire into the tube slide the antenna tube through the cable gland and tighten ensuring the rubber seal is in place For installations such as electric gates the unit should be mounted next to or near the gate control box If using a different antenna this may be connected to the terminals on the receiver PCB via the cable gland in the top of the case The REC 14 should be mounted as high as possible for best reception PCB Layout Antenna Learn Switch amp LED DIP switch Relay function RF Module Power Relay connections Learning Fobs This receiver is code learning therefore making the addition of extra transmitters an easy task If the receiver is being set up for the first time it is advisable to clear the EEPROM memory read Deleting Fobs and Reset Timings Press the LEARN DELETE switch briefly The LED will flash rapidly LEARN a fob to the receiver by pressing a button on the fob The LED will stop flashing whilst a signal is received and then start flashing again once you have stopped pressing the button indicating a successful learning of the fob NB the first learned fob will be marked as the Master Fob Learn additional transmitters or exit by pressing the LEARN DELETE switch once LED off If you forget to exit learn mode flashing LED the receiver will do so automatically after 18 seconds of no activity Set Timing The timings of each relay can be set by any learned fob NB the relays are factory set
5. vices Country of Manufacture Warranty 9 to 24VDC 9 to 24VAC Standby 14mA All relays 56mA Standby 28mA All relays 75mMA Standby 28mA All relays 73mA IP65 Case 160mm x 90mm x 55mm Antenna tube130mm Bulkhead case 108x70x34 ABS plastic 4 SPDT relay 1 Amp switching Contacts are voltage free Yes diode 315MHz 433MHz and 868MHz AM ASK Keelog Code Hopping 4 2 billion 255 fobs China maximum 24VDC Microlatch Pty Ltd warrants this product to be free from defects in materials and workmanship for a period of 1 Year from date of purchase We will in the event of failure repair or replace the product at our sole discretion This warranty does not apply in the event of accidental damage abuse misuse non approved purpose or act of God This warranty is given in addition to any rights allowed by Australian law Microlatch reserves the right to change specifications without notice in the interest of product development REC 14 4 Channel RF Receiver Controller Standard Version Indoor REC 14 IP65 Version Outdoor REC 14 IP65 Watch Copyright 2010 Microlatch Pty Ltd Installation Outdoor The REC 14 IP65 case should be wall mounted using the four 4 holes in the bottom of the case These are outside the sealed area of the box so water ingress is minimised The product is supplied with a seal for the lid of the case This should be installed into the groove in the lid Cut any excess o