Home
        Installation and Operating Instructions
         Contents
1.  the exclusion of all other liquids   without first obtaining the written   approval from Davey Products Pty Ltd    Hardness of water  TH   max  350ppm   Recommended   flow velocity  between 0 5  and 1m s max    NOTE  This pump is not approved nor  intended for use in swimming  pools  spa pools or spa baths    2  SAFETY   Read this data sheet carefully before   installing and starting up  Pay special   attention to the points concerning the  safety of the equipment for the end user     Symbols used in the manual    2 1  JN Warning    AN Instructions concerning electricity    Calls attention to a potential  risk that might affect safety     3  TRANSPORT AND STORAGE    When taking delivery of the equipment   check that it has not been damaged in  transit     If the equipment delivered is to be  installed at a later time  store it ina    dry place and protect it from impact  and outside influences  moisture   frost  etc      4  PRODUCTS AND ACCESSORIES    4 1 The Pump   With threaded ports according to model   The motor has a wet rotor and the  bearings are self lubricating   Three speed with manual selection by  selector switch     e Compliance  TF10  e Insulation class  F  155  C   e Protection  IP42     only with terminal box at 6  clock  position on SS30 25      4 2 Accessories   Supplied  Unions with gaskets   Recommended  Non return valves  Isolating valves    5  INSTALLATION    5 1 Assembly  see FIG  1 amp 2      Make sure that the circulator is  accessible      Assemble 
2. Davey   Repair or Replacement Guarantee    In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction  within 1 year of the date of original purchase due to faulty materials or manufacture  Davey will at  our option repair or replace it for you free of charge  subject to the conditions below     Should you experience any difficulties with your Davey product  we suggest in the first instance that  you contact the Davey Dealer from which you purchased the Davey product  Alternatively you can  phone our Customer Service line on 1300 367 866 in Australia  or 0800 654 333 in New Zealand  or  send a written letter to Davey at the address listed below  On receipt of your claim  Davey will seek to  resolve your difficulties or  if the product is faulty or defective  advise you on how to have your Davey  product repaired  obtain a replacement or a refund     Your Davey 1 Year Guarantee naturally does not cover normal wear or tear  replacement of product  consumables  i e  mechanical seals  bearings or capacitors   loss or damage resulting from misuse  or negligent handling  improper use for which the product was not designed or advertised  failure to  properly follow the provided installation and operating instructions  failure to carry out maintenance   corrosive or abrasive water or other liquid  lightning or high voltage spikes  or unauthorized persons  attempting repairs  Where applicable  your Davey product must only be connected to the vol
3. directly on a pipe  preferably  vertical  and if possible on the boiler  return circuit  never at the low point  to  protect against deposits       The motor shaft axis must always be  horizontal      The arrow on the pump casing indicates  the direction of water flow  see FIG  3       Install isolating valves on both sides of  the circulator to facilitate removal for  servicing     ATTENTION     If the circulator must    be insulated  we advise  against obstructing the  evacuation notches in the  motor flange  see FIG  3      5 2 Orientation of terminal box  see  FIG  4    If necessary  the orientation of the motor    and with it that of the terminal box  can be   changed      Remove the motor attachment screws  and turn the motor to the desired  position     Take care not to damage the  JN casing gasket  and reinstall it  correctly     The terminal box should not be  placed at 3 and 6 o   clock on an  cold water circuit     5 3 Electrical connection    The electrical connect must be  made by a qualified electrician  and comply with applicable local  standards     Complete electrical information about the  circulator is given on the data plate     Power supply network   Use a three conductor cable  3 x   1 5mm 7  to connect mains power to the  corresponding terminals of the circulator   phase  L   neutral  N   and earth      see  FIG  5      The power cable must not touch  the pipe or the pump  make sure  that it is away from any moisture     Check line   protection and the 
4. efore doing any work on  it     8 1 The circulator is noisy    a  Air in circulator     Bleed the circulator  loosen the rear  plug  continue until there are no more air  bubbles  then screw the plug back in     b  The suction pressure is too low    Raise the pressure in the circuit     c  Considerable flowing water noise    Consider a slower speed     d  Foreign bodies in impeller    Remove the motor and clean the  impeller     8 2 The circulator fails to start    a  Shaft stalled by fouling after a  prolonged shutdown    Free the shaft  remove the rear plug   Use a flat bladed screwdriver to turn the  motor shaft  Then reinsert the rear plug   see FIG  7      b  No power supply to circulator    Check that the motor is connected     Check the fuses of the installation     c  Capacitor defective     Replace it  the characteristics are  indicated on the rear data plate  uFV    For changing the capacitor lift up the  fixing clip of the capacitors wires  see  FIG  5   rep  A   For removing the wires   insert the new capacitor wires then  press the clip for locking     d  Foreign bodies in impeller    Remove the motor and clean the  impeller     J       
5. kridge Avenue    DAVEY Scoresby  Australia 3179 Penrose  Auckland 1061  Ph  1300 367 866 Ph  0800 654 333    WATER PRODUCTS Fax  1300 369 119 Fax  09 527 7654    Website  davey com au Website  daveynz co nz    Davey Water Products Pty Ltd  Member of the GUD Group  ABN 18 066 327 517       Davey is a registered trade mark of Davey Water Products Pty Ltd        Davey Water Products Pty Ltd 2011  P N 48171 4 supersedes P N 48171 3      Installation and operating instructions are included with the product when purchased new   They may also be found on our website        DEPEND ON    DAVEY    WATER PRODUCTS       Installation and  Operating Instructions             B26 20  fue 098 123455        csr    Circulator Pumps   C20 25  SB25 20  SB30 25    30 25          Please pass these instructions on to the operator of this equipment     1  GENERAL    1 1 Applications   SC20 25   For faster circulation of water in closed    circuit domestic  individual  central heating  and air conditioning systems     SB25 20  SB30 25  SS30 25   For faster circulation of hot water in      Secondary hot water distribution loops   Industrial water loops  air conditioning   cooling  tank circulating       2 Specifications   Temperature range   10   to  110  C  Ambient temperature  up to  40  C  Max  service pressure  10 bar   Min  suction pressure  1 5m  0 15 bar     e o o o          m w g    at  82  C   3m  0 3 bar   at  95  C   10m  1 bar  at   100  C  e Antifreeze   water   glycol   up to 50      with
6. mains  voltage and frequency  The circulator  must be connected to the mains via a  switch with an opening distance  on  each pole  of at least 3mm  The motors  of the circulator models SC  amp  SB are  self protected by impedance  therefore  they don   t need external protection  The  motors of the circulators SS need a  contactor with overload fitted  The power  outlet must have an earthing contact   After making the connections  put the  cover back on the terminal box     6  STARTING UP  6 1 Filling  degassing    Never operate the circulator  WITHOUT WATER    Open the valves on both sides of   the circulator and fill the installation  completely    Bleed the circuit at the high point   Bleed air from the circuit  by hand  by  unscrewing the plug  see FIG  6  a few  turns  close it when water runs out and  when there are no more air bubbles     ATTENTION    Risks of scald  Use a    screwdriver for unscrewing  the tap       Power up the motor to start the  circulator      The flow rate is adjusted by changing  the speed of rotation of the motor using  the selector switch     Risk of burning  In    operation  the motor casing  may be hotter than 100  C     7  SERVICING   The circulator needs no special servicing  in operation  The motor bearings are  lubricated by the liquid pumped    At the beginning of each heating season   or after a prolonged shutdown  make sure  that the circulator turns freely     8  OPERATING TROUBLE  Causes and remedies  Switch the circulator OFF    b
7. tage  shown on the nameplate     Your Davey 1 Year Guarantee does not cover freight or any other costs incurred in making a claim   Please retain your receipt as proof of purchase  you MUST provide evidence of the date of original  purchase when claiming under the Davey 1 Year Guarantee     Davey shall not be liable for any loss of profits or any consequential  indirect or special loss  damage  or injury of any kind whatsoever arising directly or indirectly from Davey products  This limitation  does not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to  your Davey product under the Australian or New Zealand legislation and does not affect any rights or  remedies that may be available to you under the Australian or New Zealand Consumer Legislation     In Australia  you are entitled to a replacement or refund for a major failure and for compensation for  any other reasonably foreseeable loss or damage  You are also entitled to have the goods repaired  or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major  failure     Should your Davey product require repair or service after the guarantee period  contact your nearest  Davey Dealer or phone the Davey Customer Service Centre on the number listed below     For a complete list of Davey Dealers visit our website  davey com au  or call     AUSTRALIA NEW ZEALAND    DEPEND ON Customer Service Centre Customer Service Centre  6 Lakeview Drive  7 Roc
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  以 ドのとおり一般競争入札を実施するので、 契約条項承知のうえ参加  volkshochschule tübingen - Deutsches Institut für  38-588型 取扱説明書 保証書別添 ガス給湯器用別売品 シャワーリモコン  EUROLITE LED Floodlight 252 6000K User Manual  Pioneer DV-420V-K  YAGー  MA-1535 SERIE - TOSHIBA TEC Europe Extranet  1 Service Manual CoaLAB 6000  Electronic Flap Controller EFC-P Installation and User manual    Copyright © All rights reserved. 