Home
        AS0922MP-CL Serial No
         Contents
1.           7  When all the air is purged from the tank  water  begins to flow steadily from the drain   slowly  open the main supply valve all the way  Allow the  water to run into the drain until the water appears    clear  Turn off the water supply and wait for a few  minutes to allow all trapped air to escape from the    tank  Then open the inlet valve bypass inlet  slowly and allow the backwash to time down     8  Press the    regen    button and allow valve to  position into the draw cycle  Once the valve is  positioned and display registering a time down  then again press  regen  and allow to advance to  rinse     Once again when display starts to count  down press  regen  button     9  Display will register a small backwash time and  then move down to fill     10  Allow to fill the brine compartment  Check that  water is slowly flowing into the brine well by lifting  up the brine well cap     11  Allow to time out and note water level in brine  compartment  The compartment should have  been prior filled with salt  The valve will then go  back into the service mode     AS0922MP CL      Allow the salt to dissolve in the brine    compartment for at least 30 minutes       Itis recommended to give a new softener a    complete regeneration before placing fully into  service       Press and hold the  regen  button until the display    starts to blink and go into the backwash mode       Allow to count down to the draw mode  When the    valve is in this mode and counting down ch
2.       Water Conditioner Regeneration                                             20  Automatic Regeneration  Manual Regeneration  Care of Your Water Conditioner                                               20  General  Cleaning the Injector Injector Screen  Maintaining the Drain Line  Brine Line and Brine Tank Overflow Connection                        21  Placing Softener into Operation                                               22  Valve Manual     6            assa Ese dd adi s    agenda dii ae            23 25  Replacement                     ede noo horno a anna aba rage               26 38  Service InstruCTiO DS ioo oe ean ee eua uo euge                   eu vMe    prex        39 46  Troubleshooting ovaa aaa aa aaa aja asa a aoc aao oen arua neus aida nx 47 49  Alarms  Troubleshooting Procedures  Glossary of Terms aaa avau dada aja kajaka aka aka da daa kaaa 50  Safety  Caution Warning  The plug in transformer for this Never attempt o work on this control while  equipment is rated for indoor use standing in or near water without  only  disconnecting electrical power to the  control                 AS0922MP CL Page 15       Introduction    The Model E1 Control provides sophisticated   demand based water conditioning by incorporating a  microprocessor and a water meter to electronically  monitor the amount of water used daily  The control is  factory programmed to regenerate when the volume  throughput setting is reached at a present delayed  time of 2am     It is rec
3.     Remai ingM           M Days             Backwash  Draw  Rinse   Fill          be TA TV        Rerrainirg M Hor       Days       se Bakwas             Draw  x 1000 Rinse    Regen                               RemaningM              M Days    Set Backwash  Tntal gg    Draw  X 1000 Rinse  Regen Fill                     Hour M Days               wm Backwash  X 1000 Rinsc  Regen Fill  NEXT          M   REGEN             M  Hour M Days    Tima  Sel    Backwash  Total    Draw  x 1000   c 1    Rise  Regen Fit           V   REGEN    Rerraining M Hour M Days    imc                 Daw  Rnse   Fil    Total  X 1000  Regen       LEAN    AS0922MP CL    General Display   When the system is operating  one of four displays  may be shown  Pressing NEXT will alternate between  the displays shown below     User 1  Shows volume remaining to regeneration     User 3  Displays flow rate M   hour     User 4  Displays total flow in cubic metres since last reset   Can be used to estimate average daily usage     PRESS DOWN ARROW FOR 3 SECONDS TO  RESENT TO ZERO     User 5  Shows current time     Setting Time of Day   Push NEXT button until time of day screen is  displayed  Press and hold the V or A arrow until the  correct hour is displayed     Then press NEXT button  The minutes will flash   Press the    or V arrow until correct minute is  displayed     Press the NEXT button to return to the display  screens  If the NEXT button is not pressed hours or  minutes will flash for five minutes before ret
4.   Failure to  do this could cause interior damage to the drain line  flow control fitting     When assembling the installation fitting package  inlet  and outlet   connect the fitting to the plumbing system  first and then attach the nut  split ring and o ring   Heat from soldering or solvent cements may damage  the nut  split ring and o ring  Solder joints should be  cool and solvent cements should be set before  installing the nut  split ring or o ring  Avoid getting  primer and solvent cement on any part of the o rings   bypass valve or control valve     Position the softener within 1 1  metres of a 10 amp    GPO  The transformer is connected into the plug  socket on the back of the valve control panel  Do not    Page 17    drop the transformer or have the cable too taut  The  transformer is only suitable for internal use only    For full understanding of the water softener we  recommend that the instruction manual be fully read  before installation and commissioning of the softener  by undertaken     IMPORTANT  A NUMBER OF VALVE  COMPONENTS ARE LOCKED INTO POSITION  WITH EASILY REMOVABLE CLIPS   ENSURE ALL LOCKING CLIPS ARE CORRECTLY  IN POSITION BEFORE PRESSURISING THE  SOFTENER  ENSURE THAT IT IS POINTED OUT  TO ALL RELEVANT PERSONNEL THAT THE  LOCKING CLIPS MUST NOT BE REMOVED  WHILST THE SYSTEM IS UNDER WATER  PRESSURE     Note  All electrical connections must be connected  according to local codes     Install grounding strap on metal plates     Bypass Valve    The by
5.   Incorrect backwash controller  a  Contact dealer   excessively low or high b  Foreign matter affecting controller b  Remove backwash controller  Clean  amp   rate  operation    replace   11  Flowing or dripping water   a  Internal valve malfunction  a  Contact dealer     at drain line after  regeneration              AS0922MP CL    Page 53       Microprocessor Troubleshooting Procedures                                                          Problem Possible Cause Solution  a  AC Adapter unplugged a  Connect power  1  Timer does not display time b  No electric power at outlet b  Repair outlet or use working outlet  of day  c  Defective AC adapter c  Replace AC adapter  d  Defective PC board d  Replace PC board  a  Switched outlet a  Use uninterrupted outlet  2  Timer does not display correct b  Power Outage b  Reset time of day  time of day  c  Defective PC board c  Replace PC board  a  Bypass valve in bypass position a  Put bypass valve in service position  3  No softening filtering display b  Meter connection disconnected b  Connect meter to PC board  when water is flowing  c  Restricted stalled meter turbine c  Remove meter and check for rotation  or foreign material  d  Defective meter d  Replace meter  e  Defective PC board e  Replace PC board  a  power outages a  Reset control valve to correct time of  4  Control valve regenerates day  at wrong time of day  b  Time of day not set correctly b  Reset to correct time of day  c  Time of regeneration incorrect c  Reset re
6.  0 95 1021pm  Volume Range 0 500 250 0 m        Totaliser    0 001 9 999 000    gt           DIMENSIONS  amp  WEIGHT       Distributor Pilot    1 050  OD Pipe  3 4  NPS                                      Drain Line 3 4   20mm  Hose Tail  Brine Line 3 8  OD Poly Tube  Mounting Base 2 12    8 NPSM  Height from Top of Tank 7 3 8   187mm   Weight 4 5lbs  2kg   Distributor Pilot 12mm Above Tank Top  ELECTRICAL SPECIFICATIONS AC Adaptor   Supply Voltage 230V AC   Supply Frequency 50 Hz   Output Voltage 12   16 V AC   Output Current 500 mA                         CYCLES OF OPERATION Range  times minutes Factory Set  Backwash 1      upflow  1 20 12  Regenerate draw slow rinse  downflow  1 99 70  Backwash 2 4  upflow  1 20 or OFF OFF   Fast Rinse  downflow  1 20 or OFF 10  Regenerant Refill  in service with treated water  0 1     99 9 9          Service  downflow                  Noryl is a trademark of General Electric           AS0922MP CL    Page 12       Table of Contents    SPOCHICATIONS MR 10  IntrodU  cliOn ea   ik ova daza sawed cede ERE e ERRORES RE           12    Special Features   General Conditioner Information                                         How Your Conditioner Works  Model E1 Control Front Panel    Installation     important installation details                                  Bypass Valve em    Screen Display Information and Programming Instructions       17 19    General Display Status  Regeneration and Error Display Status  Basic Button Function          
7.  2am    The control valve is compatible with a variety of resin  cleaners  The control valve is capable of routing the  flow of water in the necessary paths to regenerate  water treatment systems  The injector regulates the  flow of brine  The control valve regulates the flow  rates for backwashing  rinsing and the replenishing of  treated water into a regenerant tank     The control valve uses no traditional fasteners  e g   screws   instead clips  threaded caps  nuts and snap  type latches are used  Caps and nuts only need to be  firmly hand tightened because radial seals are used   Tools required to service the valve include one small  blade screw driver  one large blade screw driver   pliers and a pair of hands  A plastic wrench is  available which eliminates the need for screwdrivers  and pliers  Disassembly for servicing takes much less  time than comparable products currently on the  market  Control valve installation is made easy  because the distributor tube can be cut 12 7mm    2    above to 12 7 mm          below the top of tank thread   The distributor tube is held in place by an o ring seal  and the control valve also has a bayonet lock feature  for upper distributor baskets     The AC adapter power pack comes with a 2 0 meter  power cord and is designed for use with the control  valve  The AC adapter power pack is for dry location  use only     e Solid state microprocessor with easy access  front panel settings      Front panel display for time of day  volume  r
8.  AS0922MP CL    Page 54          9  Time of day flashes on and off          the valve     a  Power has been out more than two hours   the AC adapter was unplugged and then  plugged back into the wall outlet  the AC  adapter plug was unplugged and then  plugged back into the board or the NEXT  and REGEN buttons were pressed to reset    a  Reset the time of day          Glossary of Terms    Alarms   Display errors alert you to operating conditions  requiring attention  The display shows the type of  error  Refer to the Alarms section in this manual  for additional information     Backwash    An upward flow of water  which expands the resin  bed to remove foreign particles     Brine    The salt solution which regenerates the  conditioner s resin bed     Brine Draw    The process of drawing the brine solution from the  salt storage tank into the resin tank     Fast Rinse  Purge     A flow of water through the resin bed which propels  any remaining brine solution out of the resin tank to  the drain     AS0922MP CL    Hardness  A common quality of water containing dissolved  calcium  magnesium and other elements  Water    hardness is usually expressed milligrams per litre  as calcium carbonate equivalent     Manual Regeneration    Forces the control to regenerate by pressing the  REGEN button     Regeneration  Includes the backwash  brine draw  and fresh water    rinse steps necessary to prepare the resin bed for  conditioning after exhaustion     Regeneration Indicator    The disp
9.  Injector    Unscrew the injector cap and lift off  Loosen cap with special wrench or pliers if necessary  Attached to the  injector cap is a screen  Remove the screen and clean if fouled     The injector can be pried out with a small screwdriver  The injector consists of a throat and a nozzle   Chemically clean the injector with vinegar  The holes can be blown out with air  Both pieces have small  diameter holes that control the flow rates of water to insure that the proper concentration of regenerant is used   Sharp objects  which can score the plastic  should not be used to clean the injector  Scoring the injector or  increasing the diameter of the hole could change the operating parameters of the injector  Push the injector  firmly in place  replace the screen and hand tighten the injector cap     Two holes are label    DN    and    UP     Check for compliance  See Compliance table    AS0922MP CL Page 45    Compliance Table             Application Injector and or Main Regenerant Stack Body  Plug s  Piston Piston  WS1EI Downflow Softener or Injector in    DN    hole  V3011 V3174 V3005   V3001    Regenerating Filter                      Refill Flow Control Assembly or Refill Port Plug    To clean or replace the refill flow control  pull out the elbow locking clip and then pull straight up on the elbow   Replace the elbow locking clip in the slot so that it is not misplaced  Twist to remove the white flow control  retainer  The flow control can be removed by prying upward th
10.  Locate the cabinet softener in  an accessible place so that salt can easily be  added    e Do not install any unit closer than 3m  10ft  of  piping between the outlet of the water conditioner  and the inlet of the water heater  Water heaters  can transmit heat back down the cold water pipe  into the control valve  Hot water can severely  damage the controller     A 3m total pipe run  including bends  elbows etc  is a  reasonable distance to prevent hot water damage  A  positive way to prevent hot water from flowing from a  heat source to the conditioner is to install a check  valve in the soft water piping from the conditioner  If a  check valve is installed  make sure that the water   heating unit is equipped with a properly rated  temperature and pressure safety relief valve  Always  conform to local codes     e Do not locate the unit in an area where the temp  ever falls below 1  C  34  F  or over 49  C  120  F       Do not install the unit near acid or acid fumes      Do not expose the unit to petroleum products     Water Line Connection    A bypass valve system must be installed to provide  for occasions when the water conditioner must is by   passed for hard water or for servicing  Bypass offers  simplicity and ease of operation  These softeners are  equipped as standard with a bypass valve  See pages  14 and15    Figure 3     Ty       Conditioner       Drain Line Connection     to sewer    AS0922MP CL Page 16    The ideal location for the unit is above and not more  t
11.  SUPPLY WATER  CONDITIONED WATER TO TOP CF TANK  FROM DISTRIBUTOR    flow diagram   backwash          TO DRAIN    PISTON ROD IE   a BELOW 2nd SIEP               OUT_CT PORT FOR   SERVICE WATER    BACKWASH WATER  SUPPLY WATER TO DRAIN  TO DISTRIBUTOR    Flow Diagram     Downflow    AS0922MP CL Page 39    flow diagram   downflow brine       REGENERANT IN  MANIFOLD     TC        REGENERANT  IS SIPHONE2 IN                REGENERANT TRAVELS  THROUGH MANIFOLD        p       THE INJECTOR p                          Vi       2  LY           7      PISTON ROD IS  2 my       BELOW 3rd STEP DOWN          24  6              SUFFLY    WATER    OJ LET SERT FOR        7    SERVICE WATER    SUPPLY WATER AND REGENERANT    WASTE WATER  FROM DISTRIBUTOR 10        OF TANK    Flow Diagrams     Rinse and Fill    AS0922MP CL Page 40    flow diagram   rinse       TO IKAN    PISTON ROD IS  dih STEP DOWN                 A        ree            e                  SL Y ZANE SIM     WATER    I 1 CAL I             p    ONTI ET PORT FCR  SERVIE               SUPPLY WATER  INLET    CONDITIONED WATER STO OF TANK    FROM DISTRIBUTOR    flow diagram   fill    CONDITIONED A773  TO REGENERANT TANK         M  nnm         INS         SE    PISTON ROD IS  BELOW tst STEP DOWN                  SUPPLY T TES a  Ge          4    E a   WATER Med od Uum f              2    2     JE         d    JZUILEIFCH  FON  SERVICE v   1ER    CONDITIONE 2 WATER SUPPLY WATER  FROM DISTRIBUTOR TO TCP OF TANK    WS1 Wrench   Order No  V31
12.  memory except for  the current time of day    Current time of day   When power is restored the display will show zeros and will again register when the current time of day is  reset  If power is lost during a regeneration cycle the valve will remain operational in the current cycle and will  recommence electrically in that cycle when power is restored    In long power outages it is advisable to check that the system is not in a regeneration cycle that could be  discharging water to drain and in this instance it would be advisable to place the valve in bypass mode until  power is restored    General   Note  When changing valve operational cycles the valve control will emit a number of whirring sounds     Note    The valve cannot be positioned into the regeneration mode without ELECTRIC Power     Note   It is very important that on commissioning the tank and valve be completely vented of air      AS0922MP CL Page 10    MODEL AS0922MP WATER SOFTENER  WITH CONTROL VALVE SERIES MODEL WS1EI       AS0922MP CL Page 11    GENERAL WS1 CONTROL VALVE SPECIFICATONS          Inlet Outlet Fittings    25mm BSP  F  PVC elbows                         Cycles 5   Valve Material Noryl  1  or equivalent  Regeneration Down flow   FLOW RATES   Service  215psi 1 bar drop  includes bypass  amp  meter  102 Ipm   Backwash  25psi 1 7 bar drop  includes bypass  102 Ipm          OPERATING PRESSURE       Minimum Maximum    330 600 kpa  48 100 psi                    METER   Accuracy    596   Flow Rate Range
13.  screw capped bottle  Add one  1     tablet to sample  shake or crush to disintegrate  Repeat until last trace  of reddish tinge disappears  The final colour is usually blue but with  some water a greyish coloured end point is obtained     Using 50ml sample    Hardness ppm    number of tablets x 40    20    LR  BW  Tablets    Directions  Take a 100ml sample of water in a screw capped bottle  Add one  1     AS0922MP CL    tablet to sample  shake or crush to disintegrate  Repeat until last trace  of reddish tinge disappears  The final colour is usually blue but with  some water a greyish coloured end point is obtained     Using 100ml sample    Hardness ppm    number tablets x 2      1    Contact IBC Water if further details are required     Page 7    MODEL AS0922MP CL SOFTENER       THE MICROPROCESSOR CONTROL WILL REQUIRE BASIC DATA PROGRAMMING TO SUIT THE  RAW WATER HARDNESS AND DESIRED UNIT CAPACITY    IMPORTANT  IT IS ESSENTIAL THAT YOU READ THE GENERAL CONDITIONER INFORMATION AND  CONTROL SETTINGS OF THIS MANUAL BEFORE ATTEMPTING TO SET THE FUNCTIONS OF THIS  UNIT  THE DEALER OR AGENT CAN SUPPLY THE RAW WATER HARDNESS  HOWEVER DO NOT  EXCEED THE MAXIMUM THROUGH PUT IN CUBIC METERS BASED ON THE ACTUAL RAW WATER  HARDNESS FIGURE IN TABLE 2     SUGGESTED SETTINGS     VOLUME THROUGHPUT IN CUBIC METRES Based on Maximum Exchange Capacity      TABLE 2       Raw Water Hardness    Maximum Program Setting                                  mg L CaCO  In Cubic Metres throughput   see no
14.  the time of regen  picis              hour     Press NEXT to go to Step 51  If the factory  ee    Fecit default of 2am is to be changed   Pier E eL ia    A   57     ra f Step 5I     Use V or A buttons to set the time of regen            minutes     Press NEXT to exit installer display     v  Mersrrg                       Setting Current Time of Day   X      eu me Push NEXT button until TIME of day screen is  ii displayed ie bar appears under TIME function   Press           A EAL REGEN   and hold the V OR A arrow until a arrow appears  against SET and release the button and the hour   Exit back to display screen which would normally show display flashes and then set the correct hour  Then     remaining M     Note  When in the program mode  Step 1 to press the NEXT button  The minutes will flash  Press  the V OR    arrow until the correct minutes is  displayed  Note only press        AOR V button NOT  both together     5  If it is desired to go back one program step press    regen     button to return back        Rerin  De       Press the NEXT button to return to the display screens    252 qud If the NEXT button is not pressed hours or minutes will      m  Rr flash for five minutes before returning to display  screen            A      nese   Then using the NEXT button select which screen you    wished            Recommended to leave on     remaining M       AS0922MP CL    Power outage   When electric power is interrupted the microprocessor will hold all relevant information in
15.  water  mixture ratio over the entire operating pressure range  of the control valve  The injector provides good  performance in a variety of applications  The injector  fitted has been used to suit a wide range of operating  pressures  But requires a minimum of 330 kpa to  function correctly     Injector Order Information                                  Injector order Injector Typical tank  number colour Diameter    V3010 1B Brown 7   V3010 1D Red g     V3010 1E F White Blue 10   V3010 1G Yellow 12   V3010 11 Orange 13     V3010 1K Light Green 14            Will vary with Tank Resin Volume Check with    Factory    Refill Flow Control Assembly or  Refill Port Plug    The refill flow control assembly consists of a refill flow  elbow  refill flow control retainer assembly  refill flow  control  polytube insert and nut assembly  The refill  flow control retainer fits in the refill elbow  The refill    Page 27       flow control retainer houses the refill flow control  which controls the flow rate when the regenerant tank  is being refilled  The refill flow control is a flexible  washer like part with a small orifice and a precision  moulded contour that delivers a steady 1 91pm  0 5  gpm  regenerant tank refill rate at varying inlet  pressures  Refill is accomplished with treated water     The refill flow control assembly is installed in an easy  to access refill elbow located on top of the control  valve  The refill flow control assembly is installed in  an easy to access refi
16. 8 WS1 Drive Back Plate 1  4 V3011  WS1 Piston Downflow ASY 1  5 V3174 WS1 Regenerant Piston 1  6 V3135 O ring 228 1  7 V3180 O ring 337 1  8 V3105 O ring 215  Distributor Tube  1  Not Shown V3001 WS1 Body ASY Downflow 1                       V3011 is labelled with DN     AS0922MP CL Page 31       Black Plug    Injector Cap  Injector Screen  Injector  Plug and O Ring                                                                Drawing No  Order No  Description Quantity  1 V3176 Injector Cap 1  2 V3152 O ring 135 1  3 V3177 Injector Screen 1  V3010 1A WS1 INJECTOR ASSY   BLACK  V3010 1B WS1 INJECTOR ASSY   BROWN  V3010 1C WS1 INJECTOR ASSY   VIOLET  V3010 1D WS1 INJECTOR ASSY   RED  5 V3010 1E WS1 INJECTOR ASSY   WHITE 1  V3010 1F WS1 INJECTOR ASSY   BLUE  V3010 1G WS1 INJECTOR ASSY   YELLOW  V3010 1H WS1 INJECTOR ASSY   GREEN  V3010 11 WS1 INJECTOR ASSY   ORANGE  V3010 1J WS1 INJECTOR ASSY   LIGHT BLUE  V3010 1K WS1 INJECTOR ASSY   LIGHT GREEN  Not Shown V3170 O ring 011 i  Not Shown V3171 O ring 013               AS0922MP CL    Page 32    The injector plug has one 011  lower  and 013  upper  o ring        Refill Flow Control Assembly                                           Drawing No  Order No  Description Quantity  2 H4615 Elbow Locking Clip 1  3 JCP P 6 Polytube insert 3 8  1  4 JCPG 6PBLK Nut 3 8  1  5 H4613 Elbow Cap 3 8  1  6 V3163 O ring 019 1  7 V3165 01  WS1 RFC Retainer ASY 1  8 V3182 WSC RFC 1  Not Shown H4650 Elbow   gt  with nut and insert Option         Assem
17. 93 01     AS0922MP CL Page 41    Although no tools are necessary to assemble or disassemble the valve  the WS1 wrench  shown in various  positions on the valve  may be purchased to aid in assembly or disassembly           me Loosens Drain Nut In hf          Polytube Applications NS  V  4    2         Loosens Injector And  Bypass Caps    Loosens Quick  Connect Nuts    Service Instructions    AS0922MP CL Page 42    Drive Assembly    Remove the valve cover to access the drive assembly     Disconnect the power source plug  black wire  from the PC board prior to disconnecting the motor or water  meter plugs from the PC board  The power source plug connects to the four pin jack  The motor plug connects  to the two pin jack on the left hand side of the PC board  The water meter plug  gray wire  connects to the  three pin jack on the far right hand side of the PC board     The PC board can be removed separately from the drive bracket but it is not recommended  Do not attempt to  remove the display panel from the PC board  Handle the board by the edges  To remove the PC board from  the drive bracket  unplug the power  water meter and motor plugs from the PC board  Lift the middle latch  along the top of the drive bracket while pulling outward on the top of the PC board  The drive bracket has two  plastic pins that fit into the holes on the lower edge of the PC board  Once the PC board is tilted about 45   from the drive bracket it can be lifted off of these pins  To reinstall the PC b
18. Pressure  kPa     BLUE  ORDER NO  V3010 1F  Metric Units                        AoA ale plane ola    0 5  100 200 300 400 500 600 700 800 900    Pressure  kPa     Flow Rate  lpm   L t od    YELLOW  ORDER NO    3010 16  Metric Units       40 300  amp         550 9    Pressure  kia     ORANGE  ORDER       V3010  1l  Metric Units       10 200      400 500 900                 Pressure  kPa     LIGHT GREEN  ORDER NO  V3010 1K  Metric Units       pus      500                707            Pressure  kPa     GREEN  ORDER NO  V3010  1H  Metric Units         HEHEEEBEEBREHEEEM                                              sd RN UR HRS 1    HE  ti        Flow Rate         e     FEAE        0 20 E 4   500 BOO           300  Pressure  kPa        LIGHT BLUE  ORDER NO  V3010  1   Metric Units    Flow Rate  ipm       Troubleshooting    Your water conditioning system is designed and manufactured for efficient  low maintenance service     However     if problems do occur  this section provides a list of possible causes and solutions     Alarms    The control continuously monitors itself and sends an error to the display if it detects something wrong  When  the error is sensed  the display shows the letters Err with a number from 1 to 4  Refer to microprocessor  troubleshooting procedures     Refer to table 3 to help identify the cause of a problem  You can solve some problems yourself  such as low  salt in the storage tank or a blown household fuse  However  some problems require installer or de
19. TH MODEL WS1 VALVE EI CONTROL       Check the equipment upon arrival for damage or shortages and report same to our Office or Agent before  starting     Position the Softener on a firm foundation  preferably concrete  with sufficient space for operation and  maintenance  The softener must be within One and a Half metres of a 240V 10 amp Power Outlet  The  softener MUST be installed under cover and protected from the weather as the Valve control and Transformer  are not waterproof     STEP 1 The Softener is supplied with the resin preloaded in the tank and the valve  bypass assembled  on the tank   STEP2 Connect the Inlet and Outlet pipes and Drain line to the control valve as per the instruction    book installation details  Note the directional arrows on the Valve  The inlet is on the right  hand side facing the front of the valve  The drain is from the larger elbow on the top of the  valve  The valve Inlet and Outlet threads are 25mm BSP Female with a 12mm push on Hose  connection for the drain line     STEP 3 Remove front lid from the cabinet  Then connect cabinet brine overflow drain line to waste  trap    STEP 4 Load 2 bags of 25kg high purity water softener salt into the brine tank and replace lid    STEP 5 Refer to Instruction booklet for start up procedure  placing conditioner into Service      NOTE  The INLET PIPE connection is on the right hand side as viewed  from the front of the valve    NOTE  The POWER connection transformer socket is on the right hand  side as 
20. WATER SOFTENER  WITH MICROPROCESSOR  INSTALLATION  amp  OPERATING  INSTRUCTIONS    Model   AS0922MP CL  Serial No         Manufacturer and Supplier of    IBC FILTRATION  amp  WATER TREATMENT PRODUCTS  lt     Mein                               Se for commercial  industrial and residential application Qualit            Telephone   07  3219 2233 Facsimile   07  3219 2266    Email  sales  ibcwater com au Website  www ibcwater com au             AS0922MP CL Page 1    GENERAL WATER SOFTENER  PERFORMANCE DATA SHEET    Recommended Approx   Maximum Pipe Size Resin   Shipping Space  Service Flow Volume   Weight   Required     kg   Inlet                                Litres Per Kg metres  AS0922MP CL 770 1 4 1540 5 3 16  22 BEBE    BRINE CHAMBER  POLY MOULDED    Capacity  amp  Salt    Automatic  Dosage    Model No        System Operating Pressure  330  690 kPa    Temperature  4  x 43  C   Electrical  240V   16VAC 50Hz 3 watts maximum   Control Valve  Series WS1 E1 with bypass valve and installation  fittings     A pressure reduction valve must be installed in areas of high water pressure  above 690kPa     A water hammer arrestor must be installed if water hammer prevails  between the softener and the  closing off device     Caution  Do not use where water is microbiologically unsafe or with water of unknown quality     FAILURE TO OBSERVE WARNINGS WILL VOID WARRANTY       AS0922MP CL Page 2    AS0922MP CL Page 3    BASIC INSTALLATION    OF  IBC CABINET WATER SOFTENER SYSTEM    FITTED WI
21. aker open  or   b  Correct the electrical problem   circuit switched off   4  Control does not a  Transformer unplugged  a  Plug transformer into outlet  plug trans   regenerate former cable into control   automatically  b  Defective control  b  Contact dealer           AS0922MP CL Page 52    Table 3     Troubleshooting Procedures      cont                            6  Control does not draw a  Low water pressure a  Increase water pressure   brine  b  Restricted drain line  b  Remove restriction   c  Injector or injector screen plugged      c  Clean injector and screen  Refer to the  Cleaning the Injector Injector Screen  section in this manual   d  Injector defective    d  Replace injector  Contact dealer   e  Valve general malfunction e  Contact dealer  f  Air check prematurely closed in f  Replace or repair air check if needed   brine tank Check brine line connections   7  Intermittent or irregular a  Low water pressure  a  Increase water pressure   brine draw  b  Defective injector    b  Replace both injector and injector cap   Contact dealer   8  Brine tank overflow  a  Airleak in brine line to air check  a  Check all connections in brine line for  leaks   b  Refill program setting incorrect  b  Contact dealer   9  System using more or a  Inaccurate program setting of brine   a  Contact dealer   less salt than estimated  refill   b  Air check system incorrect  b  Contact dealer   c  Defective brine refill operation c  Contact dealer   control  10  Control backwashes at a
22. aler    assistance        Caution          Service procedures that require the water pressure to be removed from the system are marked with  a   after the possible cause  To remove water pressure from the system  put the bypass valve into  the shut off position and open the service line valve  Restore system water pressure when the  service work is completed           Table 3     Troubleshooting Procedures                            Problem Cause Solution  1  Hard water at the tap  a  Low or no salt in the salt storage a  Refill the salt storage tank and manually  tank  initiate a regeneration  Refer to the  Manual Regeneration section in this  manual    b  Capacity setting to low to b  Reduce the capacity setting  Refer to the  accommodate water hardness or Capacity Setting section in this manual   water usage    c  Unit did not regenerate  c  Check power    d  Plugged injector    d  Clean injector and screen  Refer to the   Cleaning the Injector Injector Screen  in this manual    e  Air check valve prematurely closed    e  Replace brine riser pipe if needed   in brine riser pipe  Check brine line connection for air   tightness   2  Hard water leakage a  Improper Regeneration  a  Check that the correct salt dosage is  during service  used  Repeat regeneration    b  Internal seal problem  b  Contact dealer    c  O ring around riser tube damaged      c  Contact dealer    3  Loss of power to the a  Transformer unplugged  a  Connect the power   System  b  Fuse blown  circuit bre
23. bly includes V3182 WS1 RFC     AS0922MP CL    Page 33               Water     Flow  Froper RFC orientation  directs refill water flow  towards the washer face Haa  with rounded edge anc   EL E  text  pe     Drain Line     34                                                                            Drawing No  Order No  Description Quantity  1 H4615 Elbow Locking Clip 1  PKP10TS8   2 BULK Polytube insert 5 8 Option  3 V3192 WS1 Nut   Drain Elbow Option  4 V3158 01 WS1 Drain Elbow 34 Male 1  5 V3163 O ring 019 1  6 V3159 01 WS1 DLFC Retainer        1  7 V3162 007 WS1 DLFC 0 7 gpm for 34 2 6 lpm One DLFC  V3162 010 WS1 DLFC 1 0 gpm for 34 3 8 lpm must be  V3162 013 WS1 DLFC 1 3        for 4 4 9 Ipm used if 34  V3162 017 WS1 DLFC 1 7 gpm for 34 6 5 Ipm fitting is  V3162 022 WS1 DLFC 2 2 gpm for  4 8 8 Ipm used  V3162 027 WS1 DLFC 2 7 gpm for  4 10 2 Ipm  V3162 032 WS1 DLFC 3 2 gpm for  4 12 1 Ipm  V3162 042 WS1 DLFC 4 2 gpm for  4 16 lpm  V3162 053 WS1        5 3 gpm for  4 20 Ipm  V3162 065 WS1 DLFC 6 5 gpm for  4 24 7 Ipm  V3162 075 WS1 DLFC 7 5 gpm for 4 28 5 Ipm  V3162 090 WS1 DLFC 9 0        for 4 34 2 Ipm          AS0922MP CL Page 34             V3162 100       WS1 DLFC 10 0        for 34          38 lpm       Softeners are supplied with a 20mm Push ON Hose Connection as standard the illustrated Nut and 5 8     Tube Insert are only supplied as an option        Flow  Proper DLFC orientation    directs water flow towards    the washer face with  rounded edge        Water Met
24. d  To remove the water meter assembly  unscrew the meter cap on the left side of the  control valve  Pliers may be used to unscrew the nut if necessary     With the nut removed  a slot at the top of the water meter is visible  Twist a flat blade screwdriver in the slot  between the control valve body and the meter  When the meter is part way out it is easy to remove the water  meter from the housing  Once the water meter is removed from the control valve body  gently pull forward on  the turbine to remove it from the shaft     Do not use a wire brush to clean the turbine  Wipe with a clean cloth or chemically clean in vinegar  The  turbine can be immersed in the vinegar  Do not immerse electronics  If the turbine is scored or damaged or  the bearings on the turbine are worn  replace the turbine     Do not lubricate the turbine shaft  The turbine shaft bearings are pre lubricated  Do not use Vaseline  oils  or  other unacceptable lubricants on the o ring  A silicone lubricant may be used on the black o ring     Snap the turbine on the shaft and reinsert the water meter into the side slot  Hand tighten the nut  Do not use a  pipe wrench to tighten nut     AS0922MP CL Page 46       Bypass Valve    The working parts of the bypass valve are the rotor assemblies that are contained under the bypass valve  caps  Before working on the rotors  make sure the system is depressurized  Turn the red arrow shaped handles  towards the centre of the bypass valve and back several times to ensur
25. ditioner has  reached the throughput setting volume capacity    e The REGEN button was pressed     Automatic Regeneration    The control makes regeneration decisions based on  the amount of water that has flowed through the  conditioner and the programmed throughput figure     The factory setting for Time of Regeneration is 2 00  AM  You can change this time  Refer to the  Customer Installer   Programming Instructions  section in this manual for additional information     Manual Regeneration    To force the control to perform a regeneration  press  the REGEN push button  This button is located on the  front of the control  When you press the REGEN  button  the control performs a full regeneration of the  conditioner  You can use this feature if you need a  large amount of conditioned water but the capacity  remaining is low     Note  If you press this button once and release  immediately         regeneration will occur at the  delayed time setting i e  2am  If an immediate  regeneration is required then hold in the button for 3  seconds     Care of Your Water Conditioner    General    Check the salt level in the salt storage tank regularly   Always maintain the salt level above the water level  for a consistent salt dosage and proper water  conditioner operation  Don t allow the conditioner to  run out of salt before refilling  When refilled  the salt  storage tank contains enough salt to support  numerous resin bed regenerations  It is recommended  to utilise a high grade wa
26. e  regeneration cycle   Figure 1    2  Bypass Position  The inlet and outlet handles  point to the centre of the bypass  the control  valve is isolated from the water pressure  contained in the plumbing system  Untreated  water is supplied to the plumbing system   Figure  2    3  Diagnostic Position  The inlet handle points in  the direction of flow and the outlet handle points  to the centre of bypass valve  system water  pressure is allowed to the control valve and the  plumbing system while not allowing water to exit  from the control valve to the plumbing  Figure 3    4  Shut Off Position  The inlet handle points to the  centre of the bypass valve and the outlet handle  points in the direction of flow  the water is shut off  to the plumbing system  i e  plumbing connection  somewhere in the building bypasses the system     Figure 4     Page 16    Vigure 1    NORMAL OPERATION     TREATED SUPALY WATER  WATER EXITS                   l A   7                            2  un         ayy              RES 4            ligure 3    DIAGNOSTIC MODE    SUPPLY SUPP_Y WATER  WATER EXITS ENTERS                       ie  s 7  I    AS0922MP CL       0      4   ea    Figure 2    BYPASS OPERATION    SUPPL SUPPLY WATER  WATER FXITS FNTFAS       Figure 4    SHUT OFF MODE    NO WATER SUPPLY WATER IS 8HJI OFF  EXITS FROM THE HOUSE AND THE  VALVE                        Page 19    WS1EI  Screen Display Information  And  Programming Instructions    AS0922MP CL Page 20    General Operation        
27. e exciting  current constant and moving a permanent magnet near the  semiconductor  produces a voltage output proportional to  the movement of the magnet  Hall effect devices provide a  high speed response  excellent temperature stability  and  no physical contact     Installation Fitting Assemblies    The installation fittings are used to connect the  bypass to the plumbing system  Standard fittings  supplied are a 22mm BSP female PVC elbow  assembly     Both elbow fittings have a unique drill out feature to  allow a 4    NPT connection to the inlet and or outlet  which can be used for a RO feed  test ports  pressure  tap ports  etc     Page 26    SPARE PARTS  AND  SERVICING INSTRUCTIONS    AS0922MP CL Page 29    WS1E1 Front Cover and Drive Assembly                                           Drawing No  Order No  Description Quantity   1 V3175EI 01 WS1EI Front Cover Assembly 1   2 V3107 01 WS1 Motor 1   3 V3106 01 WS1 Drive Bracket  amp  Spring Clip 1   4 V3408E1 WS1 5 PC Board El 1   5 V3110 WS1 Drive Gear 12x36 3   6 V3109 WS1 Drive Gear Cover 1  V3002El WS1EI Drive ASY   Not Shown V3186 01 WS1 AC ADAPTER CORD ONLY 1         Drawing number parts 2 through 6 may be purchased as a complete assembly  part V3002EI     AS0922MP CL    Page 30          WE1EI Drive Cap Assembly  Downflow Piston  Regenerant Piston and                                  Spacer Stack Assembly  Drawing No  Order No  Description Quantity  1 V3005 WS1Spacer Stack Assembly 1  2 V3004 Drive Cap ASY 1  3 V317
28. e hole  could change the operating parameters of the  injector  Push the injector firmly in place  replace  the screen and hand tighten the injector cap     5  Close off the tap in service line and reposition  bypass valve back into service position     Maintaining the Drain Line    The drain line discharges and brine during the  regeneration cycle  Typically  the line drains into a  sewer connection  The installer should plumb the  drain line according to local codes  leaving a one or  two inch air gap between the end of the drain line and  the drain opening     Be sure that the drain line remains unrestricted so the  regeneration water and brine can flow freely to the  drain  Do not set objects on the drain line that could  crimp the line and restrict flow     PES Right Way    Brine Line Connection    The brine line comprises a pick up air check  assembly installed in the brine wall in the cabinet and  connected by tubing to the brine elbow on top of the  valve     Note  Make sure that all fittings and connections are  tight so that premature checking does not take place   Premature checking occurs when the ball in the air  check seals before all brine is drawn out of the brine  tank  Refer to the Troubleshooting section in this  manual for additional information     Brine Tank Overflow Line Connection    In the event of a malfunction  the tank overflow  connection directs overflow to the drain instead of  spilling on the floor where it could cause water  damage  Complete t
29. e rotor is turning freely     The nuts and caps are designed to be unscrewed or tightened by hand  if necessary a pliers can be used to  unscrew the nut or cap  Do not use a pipe wrench to tighten or loosen nuts or caps  Do not place screwdriver in  slots on caps and or tap with a hammer  To access the rotor  unscrew the cap and lift the cap  rotor and handle  out as one unit  Twisting the unit as you pull it out will help to remove it more easily  There are three o rings   one under the rotor cap  one on the rotor stem and the rotor seal  Replace worn o rings  Clean rotor  Reinstall  rotor     When reinstalling the red arrow handles be sure that     1  The handle pointer are lined up with the control valve body arrows  and the rotor seal o   ring and retainer on both rotors face to the right when being viewed from the front of the  control valve  or   2  Arrows point toward each other in the bypass position     Since the handles can be pulled off  they could be accidentally reinstalled 180  from their correct orientation   To install the red arrow handles correctly  keep the handles pointed in the same direction as the arrows  engraved on the control valve body while tightening the bypass valve caps     After completing any valve maintenance  press and hold NEXT and REGEN buttons for 3 seconds or  unplug power source jack  black wire  at the circuit board and plug back in  This resets the electronics  and establishes the service piston position  The display should flash all 
30. eck to  see that brine is being drawn out of the cabinet  into the valve  The brine draw is very slow and all  brine will be drawn out until the air check on the  brine riser tube shuts off  The system will then  remain in the draw cycle to slowly rinse  And  regenerate  the brine through the resin       Allow the system to complete a full regeneration    and return to the service position  This will take a  few hours       When the unit has returned to the service position    with the normal display then open the bypass  valve outlet valve slowly to enable water to enter  the treated water line ensure that the bypass  valve is correctly in  Normal Operation  position       Open a tap in the treated water and allow to run    to drain for a few minutes  Then check the  harness of the water with the supplied test kit    If not soft allow to run to drain for 5 minutes and  recheck the hardness    Refer to  troubleshooting  section if the water is  still hard     Page 25    WS1EI Manual    Control Valve Function and Cycles  of Operation    This glass filled            or equivalent  fully automatic  control valve is designed as the primary control  center to direct and regulate all cycles of a water  softener  The control valve can be set to regenerate  on demand  consumption of a predetermined amount  of water  and or as a time clock  passage of a  particular number of days   The control valve is  factory set to regenerate on demand consumption  with a delay regeneration set for
31. emaining  current flow rate and total volume  used  Totalizer     e Four methods to initiate regeneration  meter  immediate  meter delayed  time clock  delayed or pressure differential    e Optional double backwash feature offers  optimum regeneration cleaning ability and  efficiency     AS0922MP CL    e Fully adjustable 6 cycle control delivers  controlled backwash  downflow brining slow  rinse  second backwash  fast rinse  refill and  downflow service    e  Downflow regeneration    e  12 volt output AC Adapter provides safe and  easy installation      Control valve design provides optimum  service and backwash rates    e Treated water regenerant refill    e Reliable and proven DC Drive      General Factory set up is for M   throughput regeneration with 2 AM  delayed regeneration and No second  Backwash     Manual Initiated Regeneration    The user can initiate manual regeneration  The user  has the option to request the manual regeneration at  the delayed regeneration time of 2am or to have the  regeneration occur immediately    1  Pressing and releasing immediately the  REGEN button     E   will flash towards regen  on the display and regeneration will occur at  2am the delayed regeneration time  The user  can cancel the request by pressing and  releasing the REGEN button    2  Pressing and holding the REGEN button for  approximately 3 seconds will immediately  start the regeneration  The user cannot  cancel this request  except by resetting the  control by pressing NEXT a
32. er and meter Plug                            Drawing No  Order No  Description Quantity  1 V3151 WS1 Nut 1  QC 1  2 V3003  WS1 Meter ASY 1  3 V3118 01 WS1 Turbine ASY 1  4 V3105 O ring 215 1               Order number V3003 includes V3118 01 WS1 Turbine Assy and V3105 O ring 215     AS0922MP CL    Page 35       Installation Fitting Assembly    Order No  V3007 01  Description  WS1 Fitting 34   amp  1  PVC Solvent 90 ASY                               Drawing No  Order No  Description Quantity  1 V3151 WS1 Nut 1    Quick Connect 2  2 V3150 WS1 Split Ring 2  3 V3105 O Ring 215 2  4 V3189 WS1 Fitting 34  amp  1 PVC Solvent 90 2          AS0922MP CL Page 36       Bypass Valve                                           Drawing No  Order No  Description Quantity  1 V3151 WS1 Nut 1  Quick Connect 2  2 V3150 WS1 Split Ring 2  3 V3105 O ring 215 2  4 V3145 WS1 Bypass 1    Rotor 2  5 V3146 WS1 Bypass Cap 2  6 V3147 WS1 Bypass Handle 2  7 V3148 WS1 Bypass Rotor Seal Retainer 2  8 V3152 O ring 135 2  9 V3155 O ring 112 2          AS0922MP CL    Page 37                      10 V3156 O ring 214 2             Flow Diagrams   Service and Backwash    flow diagram   service    AS0922MP CL Page 38              LLL  27227227208  i       i 7  ETE                   MARIA Ihm  SE 1   07 os          L     M IVI TT PISTON ROO 15 BOTTGHEC    ff e Lk CUT IN  HOME  POSITION  TA    iz           rm            29             MN                  SUTLET FORT FOR  SERVICE WATER        pe SUPPLY WATER    INLET   
33. generation time  d  Control valve set at    on O  d  Check control valve set up procedure   immediate regeneration  regeneration time option   a  Control valve has just been serviced a  Press NEXT and REGEN for 3 seconds  or unplug power source jack  black wire   5  Err followed by code number and plug back in to reset control valve     Error Code 1001     Unable to recognize  start of regeneration   Error Code 1002 Unexpected stall  Error Code 1003 Motor ran too long   timed out trying to reach next cycle  position   Error 1004     Motor ran too long  timed  out trying to reach home position    If other Error Codes display contact the  factory          Foreign matter is lodged in control    valve    o      Check piston and spacer stack assembly  for foreign matter         high drive forces on piston            Replace piston s   amp  spacer stack  assembly         Control valve piston not in home    position    c  Press NEXT and RGEN for 3 seconds    or unplug power source jack  black wire   and plug back in to reset control valve         Motor not inserted fully to engage    pinion  motor wires broken or  disconnected  motor failure    e  Check motor and wiring  Replace motor if  necessary         Drive gear label dirty or damaged     missing or broken gear    f  Replace or clean drive gear         Drive bracket incorrectly aligned to    back plate    9  Reseat drive bracket properly         PC board is damaged or defective    h  Replace PC board         PC board incorrectl
34. han 6 1m  20ft  from the drain  For such installations   using the appropriate adaptor fitting  supplied    connect 12mm  1 2   plastic tubing to the drain line  connection located on the top of the valve     pe Righ  Way    Figure 5   Air Gap Installation    If the unit is located more than 6 1m  20ft  from the  drain  use 20mm tubing for runs up to 12 0m  You  may elevate the line up to 1 8m providing the run  does not exceed 4 5m and the water pressure at the  conditioner is not less than 280kPa  40psi   You may  elevate an additional 500mm for each additional  70kPa   10psi  of water pressure     When the drain line is elevated and empties into a  drain which is below the level of the control valve   form a 170mm  7 inch   loop at the drain end of the  line so that the bottom of the loop is level with the  drain line connection  This provides an adequate  siphon trap     If the drain empties into an overhead sewer line  a  sink type trap must be used        Caution       Never connect the drain line into a drain   sewer line or trap  Always allow an air gap  between the drain line and the wastewater  to prevent the possibility of sewage being  back siphoned into the conditioner              ot In Bypass In Bypass    AS0922MP CL    Important Installation Details    The control valve  fittings and or bypass are designed  to accommodate minor plumbing misalignments but  are not designed to support the weight of the system  or the plumbing     Do no use Vaseline  oils  other 
35. he following steps to connect the  overflow fitting to the brine tank     1  Locate the fitting overflow on the side of the brine  tank    2  Attach a length of 1 2in  1 3cm  tubing  not  supplied  to the fitting and run to the drain     Note  Do not elevate the overflow line higher than 3in   7 6cm  below the bottom of the overflow fitting  Do  not tie into the drain line of the control unit  The  overflow line must be a direct  separate line from the  overflow fitting to the drain  sewer or tube  Allow an  air gap as in the drain line connection     Overtlow Fitting  installed        Arne Tank    Connect 1 7 inch  1 3 cm   LD  Tubing or Hose and Run 1p Drain    Overflow Line Connection    AS0922MP CL    Page 24    Placing Softener into Operation    Initial Start Up    1  Mains water turned off to unit or bypass valve in  shut off mode   Connect transformer to power point and turn on     2  3  Program controller as per    Customer Install  Programming Instructions     4  Press the    Regen    button in and hold for 3 to 5  seconds    5   6    The softener will advance to the backwash  position and start counting down     Slowly open the inlet valve or the bypass valve  into the  Diagnostic Mode  approximately one  quarter of t a turn and allow the mineral tank to  slowly fill up with water        Caution       If the water supply valve is opened too rapidly  or too far  resin may be lost  In the BACKWASH  position  you should hear air escaping slowly  from the drain line    
36. he necessary  flow passage for water during the different cycles   The all plastic spacer stack assembly  U S  Patent  6402944  is a one piece design which allows the  stack to be removed using your fingers     The exterior of the stack is sealed against the body  bore with self lubricating EPDM o rings  while the    AS0922MP CL    interior surface is sealed against the piston using  slippery self cleaning silicone lip seals  The lip seals  are clear in colour and have a special slippery coating  so that the piston does not need to be lubricated     Injector Cap  Screen  Injector Plug  and Injector    The screen  injector and or injector plug s  are  installed under the injector cap in an easy to access  location on top of the valve  The injector cap contains  four slots so no water accumulates in the cap  The  injector cap is designed to be hand tightened     Under the injector cap there is an easy to clean  removable screen to prevent fouling of the injector   There are two holes under the injector cap labelled   DN  and  UP   The injector is in the  DN  hole and  the    Up    hole is plugged    The injector lets water pass through the pathway  The  self priming injector increases the velocity of the  water  creating a zone of negative pressure that  draws in the concentrated liquid regenerant sodium  chloride  brine   The regenerant blends with the  stream of water which passes through the media to  regenerate the resin bed     The injector provides a consistent regenerant
37. hydrocarbon lubricants  or spray silicone anywhere  A silicone lubricant may  be used on black o rings but is not necessary  Avoid  any type of lubricants  including silicone  on the  clear lip seals     The nuts and caps are designed to be unscrewed or  tightened by hand or with the special plastic wrench   Do not use a pipe wrench to tighten or loosen nuts or  caps  Do not place a screwdriver in the slots on caps  and or tap with a hammer     Do not use pipe dope or other sealant on threads   Use teflon tape on threaded inlet  outlet and drain  fittings Teflon tape is not necessary on the nut  connection or caps because of o ring seals     After completing any valve maintenance involving  the drive assembly of the drive camp assembly  and pistons  press and hold NEXT and REGEN  buttons for 3 seconds or unplug power source  jack from the printed circuit board  black wire   and plug back in  This resets the electronics and  establishes the service piston position  The display  should flash all wording  then flash the software  version and then reset the valve to the service  position     All plumbing should be done in accordance with local  plumbing codes  The pipe size for the drain line  should be a minimum of 12mm     Solder joints near the drain must be done prior to  connecting the drain line flow control fitting  Leave at  least 150mm  6   between the drain line control fitting  and solder joints when soldering pipes that are  connected on the drain line control fitting
38. ive cap assembly and piston  The spacer  stack assembly can be removed easily without tools by using thumb and forefinger  Inspect the black o rings  and clear lip seals for wear or damage  Replace the entire stack if necessary  Do not disassemble the stack     The spacer stack assembly may be chemically cleaned with vinegar or wiped with a soft cloth     The spacer stack assembly can be pushed in to the control valve body bore by hand  Since the spacer stack  assembly can be compressed it is easier to use a blunt object  15 9mm  5 8   to 28 6 mm  1 1 8   in diameter   to push the centre of the assembly into the control valve body  The assembly is properly seated when at least  four threads are exposed  approximately 15 89 mm  5 8    Do not force the spacer stack assembly in  The  control valve body bore interior can be lubricated with silicone to allow for easy insertion of the entire stack  Do  not use silicone or any other type of lubricant on the clear lip seals or the piston     Reattach the drive cap assembly and piston s  and the drive assembly   IMPORTANT NOTE      After completing any valve maintenance  press and hold NEXT and REGEN buttons for 3 seconds or  unplug power source jack  black wire  at the circuit board and plug back in  This resets the  electronics and establishes the service piston position  The display should flash all wording  then  flash the software version and then reset the valve to the service position     Injector Cap  Screen  Injector Plug and
39. lay arrow which indicates the regeneration  cycle status     Resin Bed  The supply of synthetic organic exchange material  used in water conditioners  This material is subject    to degradation and will need to be renewed  Resin  replacement normally varies between 3 to 7 years     Page 55       
40. ll elbow located on top of the  control valve  The refill flow control assembly is  attached to the control valve with a locking clip  The  locking clip allows the elbow to rotate 270 degrees so  the outlet can be orientated towards the regenerant  tank     The control valve has a standard refill elbow to which  a 3 8  flexible tube can be connected  Always utilise  the supplied Tube insert     Drain Line Flow Control and Fitting  Assembly    The drain line flow control assembly includes a drain  line flow control and a fitting  The drain line flow  control allows proper media bed expansion by  regulating the flow rate to the drain  The drain line  flow control is a flexible washer like part with an  orifice and a precision moulded contour  The flow  rates are within     1096 over the pressure range of 1 4  bar  20 psi  to 8 6 bar  125 psi      The drain line flow control and fitting are located on  top of the control valve and replaceable without the  use of special tools    The drain line flow control can be installed in the  standard 34  drain line elbow  which accommodates  5 8  polytube or pipe 20mm threaded drain line  connections  The optional nut and polytube insert for  the drain line elbow is designed for use with flexible  polytube only  The drain line elbow can be rotated  180 degrees so the outlet can be orientated to the  nearest drain  This model softener is fitted with a  20mm push on hose elbow     Water Meter or Meter Plug    The water meter is installed on 
41. ly  The drive bracket is properly  seated when it snaps under the latches on the drive back plate  If resistance is felt before latching  then  notches are not fully engaged  the piston rod is not in hold  the wires are jammed between the drive bracket  and drive back plate  or the gear is not engaging the drive cap assembly     To inspect the drive gears  the drive gear cover needs to be removed  Before trying to remove the gear cover   the drive bracket must be removed from the drive back plate   Refer to the instructions above regarding  removing the drive bracket from the drive back plate  The drive gear cover can be removed from the drive  bracket without removing the motor or the PC board   The drive gear cover is held in place on the drive  bracket by three clips  The largest of the three clips is always orientated to the bottom of the drive bracket   With the PC board facing up  push in and down on the large clip on the drive gear cover  Handle the cover and  the gears carefully so that the gears do not fall off of the pegs in the cover     Replace broken or damaged drive gears  Do not lubricate any of the gears  Avoid getting any foreign matter  on the reflective coating because dirt or oils may interfere with pulse counting     The drive gear cover only fits on one way  with the large clip orientated towards the bottom  If all three clips  are outside of the gear shroud on the drive bracket the drive gear cover slips easily into place     The drive bracket does not 
42. nd REGEN  buttons simultaneously for 3 seconds     However this may totally clear all  the pre programmed in functions    and is not recommended   The WS1EI control valve consist of the following  components   Drive Assembly  2  Drive Cap Assembly  Main Piston and  Regenerant Piston   Spacer Stack Assembly   Injector Cap  Screen  Injector   Refill Flow Control Assembly   Drain Line Flow Control and Fitting Assembly   Water Meter   Bypass Valve   Installation Fitting Assemblies     php              OND OA         Drive Assembly   The drive assembly consists of the following parts   Drive Bracket    Printed Circuit  PC  Board    Motor   Drive Gears   Drive Gear Cover    Page 26    The drive bracket holds the PC board  the motor  the  drive gears and the drive gear cover in place     The PC board receives and retains information   displays the information  determines when to  regenerate and initiates regeneration  The display  show different types of information in the initial  system set up  installer display settings  diagnostics or  user display settings     The PC board powers the motor  The PC board s two   prong jack connects wires to the direct current  DC   motor  The motor is held in place on the drive bracket  by a spring loaded clip and a small bulge in the  plastic  which fits in one of the slots on the motor  housing  The motor turns drive gears that drive the  piston to cycle positions for backwashing   regeneration  rinsing  refill or service  The motor is  fully 
43. need to be removed from the drive plate if the motor needs to be removed  To  remove the motor  disconnect the power and motor plugs from the jacks on the PC board  Move the spring clip  loop to the right and hold  Rotate the motor at least a 1   4 turn in either direction so the wires are vertical  up  amp   down  before gently pulling on the wire connectors to remove the motor  Pulling directly on the wires without  rotating the motor may break the wires off the motor     Replace the motor if necessary  Do not lubricate the motor or the gears  To reinstall the motor  move the  spring clip loop to the right and hold  Gently turn the motor while inserting so that the gear on the motor  meshes with the gears under the drive gear cover  Release the spring clip loop and continue to rotate the  motor until the wires are horizontal and the motor housing engages the small plastic bulge inside the drive    AS0922MP CL Page 43    bracket motor retainer  Reconnect the motor plug to the two pronged jack on the lower left hand side of the PC  board  If the motor will not easily engage with the drive gears when reinstalling  lift and slightly rotate the motor  before reinserting  Reconnect the power plug     Replace the valve cover  After completing any valve maintenance  press and hold NEXT and REGEN buttons  for 3 seconds or unplug power source jack  black wire  at the circuit board and plug back in  This resets the  electronics and establishes the service piston position  The display 
44. oard  position the lower edge of the  PC board so that the holes in the PC board line up with the plastic pins  Push the top of the PC board towards  the valve until it snaps under the middle latch  weave the power and water meter wires into the holders and  reconnect the motor  water meter and power plugs     The drive bracket must be removed to access the drive cap assembly and pistons or the drive gear cover  It is  not necessary to remove the PC board from the drive bracket to remove the drive bracket  To remove the  drive bracket start by removing the plugs for the power source and the water meter  Un weave the wires from  the side holders  Two tabs on the top of the drive back plate hold the drive bracket in place  Simultaneously lift  the two tabs and gently ease the top of the drive bracket forward  The lower edge of the drive bracket has two  notches that rest on the drive back plate  Lift up and outward on the drive bracket to disengage the notches     To reassemble  seat the bottom of the drive bracket so the notches are engaged at the bottom of the drive  back plate  Push the top of the drive bracket toward the two latches  The drive bracket may have to be lifted  slightly to let the threaded piston rod pass through the hole in the drive bracket  Maintain a slight engaging  force on top of the drive bracket while deflecting the bracket slightly to the left by pressing on the side of the  upper right corner  This helps the drive gears mesh with the drive cap assemb
45. ommended to de rate the throughput setting  by one days general usage to ensure soft water is  available on the day of regeneration  However in  instances where this is not desired the control can be  reprogrammed so that a regeneration can be initiated  immediately on reaching the throughput setting     The control provides efficient  trouble free  soft water     The Series WS1 El valve combines design simplicity  with glass reinforced NORYL  plastic construction to  provide an uncommonly reliable appliance     If maintenance becomes necessary  the Model WS1        water Conditioner System has the capability for  quick repairs     NORYL is a trademark of GE Plastics   Special Features    e Memory Retention  During a power outage   critical operating information in the control s  memory is stored in a special electronic device  called a NOVARAM  This information includes the  time of day  water usage amounts  all  programming data  When power is restored  the  information is returned to the microprocessor and  operation resumes as if an outage never  occurred  The time of day will be late by the  length of the power outage  Because most power  outages are less than one minute in duration  it  may be months or years before the time display  requires resetting  If an outage of one or more  hours occurs  the time of day should be reset but  no other reprogramming is necessary      Design Reliability  Solid state electronics assure  many years of trouble free performance  The  me
46. or upflow piston fully extend the piston rod and then unsnap    AS0922MP CL Page 44    the main piston from its latch by pressing on the side with the number  Chemically clean in vinegar  or replace  the main piston     Reattach the main piston to the drive cap assembly  Reattach the regenerant piston to the main piston  Do not  lubricate the piston rod  main piston or regenerant piston  Lubricant will adversely affect the clear lip seals   Reinsert the drive cap assembly and piston into the spacer stack assembly and hand tighten the drive cap  assembly  Continue to tighten the drive cap assembly using a screwdriver as a ratchet until the black o ring on  the spacer stack assembly is no longer visible through the drain port  Excessive force can break the notches  moulded into the drive back plate  Make certain that the main drive gear still turns freely  The exact position of  the piston is not important as long as the main drive gear turns freely     Reattach the drive assembly to the control valve and connect all plugs  After completing any valve  maintenance  press and hold NEXT and REGEN buttons for 3 seconds or unplug power source jack  black  wire  at the circuit board and plug back in  This resets the electronics and establishes the service piston  position  The display should flash all wording  then flash the software version and then reset the valve to the  service position     Spacer Stack Assembly    To access the spacer stack assembly remove the drive assembly  dr
47. oughput in cubic metres from Table 2     2  Current time of day     NOTE  All other parameters have been factory pre set   DO NOT CHANGE     AS0922MP CL    Page 8    CUSTOMER    INSTALLER    PROGRAMING INSTRUCTIONS       The WS1 E1 has been factory programmed with the majority of the commands and parameters installed  It is  necessary on commissioning of the softener to program in the M  throughput  and if desired another time of  day when regeneration is to proceed or accept the factory default of 2am and to set up the clock to register  the current time of day  The transformer plugs into the socket mounted on the back face of the front panel of  the valve   The procedure is as follows     Plug in the transformer into the mains and turn on     valve will sequence to the service position     Step 11     To enter installer display press the NEXT  and A buttons simultaneously for 5 seconds and                release  Display flashes   De JATV  WE Step 21     Using the V A keys input desired  pup  Mfg volumetric throughput capacity  table 2   in cubic  E   are            meters   Adjustable from 0 5   250 0   It is suggested  pus 500 Rie the value entered be equal to the actual volumetric  capacity minus a 1 day   s estimated water usage        8 A    Gi E Press NEXT to go to Step 3l    Remaitens            Jatkeash Step          Use V or A buttons to Set to    OFF     d  WE Press NEXT to go to Step 4l               Ud EA    ETATEM             Step 41  Use V or    buttons to set
48. pass valve is typically used to isolate the  control valve from the plumbing system s water  pressure in order to perform control valve repairs or  maintenance  The WS1 bypass valve is particularly  unique in the water treatment industry due to its  versatility and state of the art design features  The  full flow bypass valve incorporates four positions   including a diagnostic position that allows service  personnel to work on a pressurised system while still  providing untreated bypass water to the facility or  residence  Its completely non metallic  all plastic  design allows for easy access and serviceability  without the need for tools     AS0922MP CL    The bypass body and rotors are glass filled Noryl  or  equivalent  and the nuts and caps are glass filled  polypropylene  All seals are self lubricating EPDM to  help prevent valve seizing after long periods of non   use  Internal o rings can easily be replaced if service  is required     The bypass consists of two interchangeable plug  valves that are operated independently by red arrow   shaped handles  The handles identify the flow  direction of the water  The plug valves enable the  bypass valve to operate in four positions     1  Normal Operation Position  The inlet and outlet  handles point in the direction of flow indicated by  the engraved arrows on the control valve  Water  flows through the control valve during normal  operation and this position also allows the control  valve to isolate the media bed during th
49. r  the resin cannot  remove any more minerals  This resin state is called  exhaustion and indicates that the resin needs to be  regenerated  The regeneration process restores the  conditioner s ability to soften water  The control  monitors the amount of water that flows through the  conditioner and automatically calculates when to  regenerate the resin bed     Model E1 Control Front Panel       Figure 1    The main components of the model E1 Control front  panel are   e Main Display Screen with Cycle Time Remaining  e Display screen     set as    remaining     or time of  day  e Display can indicate Rate of Flow  e Four Digit Display  Programming Push Buttons    Page 14    REGEN Push Button    Five cycle operation provides for downflow condi   tioned water  upflow backwash  downflow brining  and slow rinse  downflow fast rinse  and refill of  the brine tank  Optional second backwash  available     System operation cannot get out of phase or  sequence  The control always returns to a fixed  conditioned water position after regeneration     e Bypass untreated water is automatically available  during regeneration        AS0922MP CL Page 15    Installation    All plumbing and electrical connections must conform  to local codes  Inspect the unit carefully for carrier  shortage or shipping damage     Location Selection    e Locate unit as close to a drain as possible     If supplementary water treating equipment is  required  make sure that adequate additional  space is available 
50. reversible  turns both ways  and changes  direction of rotation to change the direction of piston  motion  The motor is easily replaced if necessary     There are three drive gears held in place by the drive  gear cover  All three drive gears are the same size  A  reflective coating is applied to the gears  As the  centre drive gear turns a light shines on the coating  and a light sensing diode determines if a light pulse  was returned  The PC board counts the pulses and  determines when to stop driving the motor     Drive Cap Assembly  Main Piston  and Regenerant Piston    The drive gears turn the main gear of the drive cap  assembly  which moves the piston  The screw driven   horizontally moving piston stops at specific positions  to direct the flow of water to backwash  regenerate   rinse or refill  The PC board determines the position  of the piston by counting pulses produced when the  piston is moved  An optical sensor looking at one of  the reduction drive gears generates these pulses   Each cycle position is defined by a number of pulses   The counter is zeroed each time the valve goes to the  service position  The PC board finds the service  position by noting the increase in current delivered to  the motor when the mechanical stop at the service  position is reached  This method of controlling the  piston position allows for greater flexibility and  requires no switches or cams  U S  Patent 6 444 127      Spacer Stack Assembly    The spacer stack assembly provides t
51. rough the side slots of the retainer with a small  flat blade screwdriver     Chemically clean the flow control or the white flow control retainer using vinegar  Do not use a wire brush  If  necessary  replace the flow control  o ring on the flow control retainer  or the o ring on the elbow     Reseat the flow control so the rounded end is visible in the flow control  Reseat the white flow control retainer  by pushing the retainer into the elbow until the o ring seats  Remove locking clip  push down on elbow to  reseat and insert locking clip     Do not use Vaseline  oils  or other unacceptable lubricants on o rings  A silicone lubricant may be used on the  o ring on the elbow or the white retainer     Water Meter or Meter Plug    The water meter assembly is connected to the PC board by a cable  If the entire water meter assembly is to be  replaced  remove the control valve cover and disconnect the power source and water meter plugs from the PC  board  Unlatch the drive assembly and lean it forward  Unthread the water meter wire from the side of the  drive assembly and through the drive back plate  To reinstall  rethread the water meter wire through the drive  back plate and the side of the drive assembly  Reattach the drive assembly and the water meter and power    plugs   If no water meter wire is visible  then a plug is installed  not a water meter     The water meter cable does not need to be removed from the PC board if the water meter is only being  inspected and cleane
52. should flash all wording  then flash the soft  ware version and then rest the valve to the service position     Drive Cap Assembly  Main Piston and Regenerant Piston    The drive assembly must be removed to access the drive cap assembly  The drive cap assembly must be  removed to access the piston s   The drive cap assembly is threaded into the control valve body and seals  with an o ring  To remove the drive cap assembly use the special plastic wrench or insert a  4  to  5  flat blade  screwdriver into one of the slots around the top 2  of the drive cap assembly so it engages the notches  moulded into the drive back plate around the top 2  of the piston cavity  The notches are visible through the  holes  Lever the screwdriver so the drive cap assembly turns counter clockwise  Once loosened  unscrew the  drive cap assembly by hand and pull straight out                        The drive cap assembly contains the drive cap  the main drive gear  drive cap spline  piston rod and various other parts that should not be  dissembled in the field  The only replaceable part on the drive cap assembly is the o ring  Attached to the drive cap assembly is the main piston   downflow  and if a regenerant is used  a regenerant piston     The regenerant piston  the small diameter one behind the main piston  is removed from the main piston by  pressing sideways and unsnapping it from its latch  Chemically clean in vinegar  or replace the regenerant  piston if needed  To remove the main downflow 
53. te   60 25 5  80 19 0  100 15 0  120 12 5  140 11 0  160 9 5  180 8 5  200 7 5  250 6 0             Important Note     To provide uninterrupted soft water  supply to the end of the service  and just before a regeneration is  due it is strongly recommended to  de rate the throughput setting by  the average daily usage  Eg  If the  setting is elected at 15 0 then  deduct a figure of one days usage    Note  Estimated daily  consumption per person is 300  litres or O 3Cubic Metres     for     people  0 9cubic metres    Deduct  One Cubic Metre    For Commercial applications it will  be necessary to determine the  daily water usage figure     For other raw water hardness multiply the throughput at 100 hard i e 15 0 by the ratio of 100 divided by    the desired hardness   e g  for 50 hard      e g  for 170 hard      15 0 x 100   30 00  50   15 0 x 100   8 8 input 8 5  170    Note  The program for M  input will only accept the inputting of a whole or half a number  e g  If the  calculated throughput is say 9 75m  then what can be programmed in is 9 5 or 10 0  However  always  select the lower figure i e  9 5 in this example  Above 50M  the program will only accept increments in  2 5   therefore only input a lower figure eg  Calculation gives 58 33 therefore input 57 5     Note    The chart is based on low to medium total dissolved solids water  consult IBC Water for using the  softener for waters above 250 mg L hardness     Programming Parameters to be input at commissioning   1  Thr
54. ter softener salt like IBC  premium grade  Do not use a fine grade of salt  Have  the salt storage tank serviced once a year to remove  accumulated sediment that may impede brine draw     Cleaning the Injector Injector Screen    AS0922MP CL    The injector is the component  which creates the  vacuum necessary to draw the brine into the water  conditioner  Clean the injector and the injector screen  once a year in order to maintain proper water  conditioning  Some locations may require more  frequent injector and screen servicing     Complete the following steps to clean the injector and  the injector screen     1  Unplug the wall mount transformer     2  Shut off the water supply or put the bypass valve  into the bypass position     3  Depressurise the pipework by opening a tap in  the service line     4  Unscrew the injector cap  large top slotted cap   and lift off  Loosen cap with special plastic wrench  or pliers if necessary  Attached to the injector cap  is a screen  Remove the screen and clean if  fouled     The injector can be pried out with a small  screwdriver  The injector consists of a throat and  nozzle  Chemically clean the injector with  vinegar  The holes can be blown out with air   Both pieces have small diameter holes that  control the flow rates of water to insure that the  proper concentration of regenerant is used   Sharp objects  which can score the plastic   should not be used to clean the injector  Scoring  the injector or increasing the diameter of th
55. tering system has only one moving part  a  rotating turbine that measures water usage    e Time and Capacity Display  During normal  conditioning operation  the correct time of day  and capacity can be accessed on the display  The  capacity value is the number of cubic metres of  water that the unit can condition before another  regeneration is needed     e Flow indicator  The display can access the  actual flow rate through the system     e Throughput and Capacity Setting  Once the  capacity setting is entered  the information cannot    AS0922MP CL    be lost due to a power outage  so reprogramming  is not necessary     e Guest Cycle  An extra regeneration can be  achieved at any time by pressing the REGEN  button on the front panel  It takes a few minutes  for the regeneration to start  The unit completes  the regeneration in about two hours  This feature  is beneficial when you expect to use more than  the normal amount of water  for example  guest  visits or an extra heavy laundry day  The manual  can be set for immediate regeneration of delayed  regeneration at 2am     General Conditioner Information    How Your Conditioner Works    In general  your water conditioner works in the follow   ing manner  Hard water flows into the conditioner and  through the resin bed where calcium and magnesium  hardness minerals are exchange  The conditioned  water flows out of the resin bed into your plumbing  system  After a certain amount of hard water has  passed through the conditione
56. the outlet side of the  control valve  The water meter uses a turbine to  measure cubic metres of treated water  The turbine  rotates with the flow of water and reports its rate of  rotation through Hall effect  circuitry to the printed  circuit  PC  board  This rotation permits the PC board  to record the total volume of treated water and the  flow rate  The small centrally located magnet is  shielded from water  which substantially reduces iron   fouling problems with the turbine     AS0922MP CL    The turbine is accurate to within     596 over a wide  operating flow rate range 0 95 lpm  0 25 gpm  up to  control valve maximums and has a very low pressure  drop  Water used for regeneration is not metered  If  the control valve is in regeneration mode  e g  a  backwash cycle  and there is a water demand  that  water usage is not metered     When facing the front of the control valve  the water  meter is positioned on the left hand side of the control  valve  Allow sufficient clearance to clean and repair  the water meter without disconnecting the plumbing or  disassembling any other parts of the control valve     Water Meter Hall Effect Explanation    3 Some semiconductor materials exhibit a phenomenon in  the presence of a magnetic field that is adaptable to  sensing devices  When a current is passed through one  pair of wires attached to a semiconductor will develop a  voltage proportional to the magnetic field present and the  current in the other pair of wires  Holding th
57. urning to  display screens     Page 21    General Regeneration Error Screens Status    Remaining M Hour M Days  Regen Screen  Backwash Displays the time remaining inthe  Bg Draw curent cycle  Pressing REGEN  Rinse advances to the next cycle   Fill              ee        i          uw   l mmen i  NEXT    SEI      MLOGCN                   4     te       Error Screen    P    Altsrmuted flashing Err and vreur  code every 3 seconds  Clear by    4 1 cGasconnecting the power supply at  tac PC board and revenncting        be   press the        and REGEN buttons                sitrintaneously For 2 seconds     Button Operation and Function    NEXT Scrolls to the nesl display     Pressing vuce and releasing will schedule    regenerition    the present delayed regeneration time   Pressing again amt releasing will cancel the regeneration   REGEN Pressing and holding  or 3 seconds will initiate an immediate regenerution  Pressing while in regeneration wil  advance to the nesi cycle   Pressing in fhe program levels will go backwards to thv previous sereen    Changes variable being displayed     Key sequenze to luck and anlock  NEXT REGEN program settings   Holding for 3 scconds tntitiules    control reset  The software  NEXT REGEN version is displayed and the piston rcturns tu the heme survice  position  resynchbronizing the valve     AS0922MP CL Page 22    Water Conditioner Regeneration    Your water conditioner regenerates for one of two   reasons    e The control determines that the con
58. viewed from the front of the valve at the back of the  control     Table 3    MODEL RESIN LITRES BRINE TANK   SALT  LOADING KG    AS0922MP CL       AS0922MP CL Page 4    AS0922MP CL Page 5    WS1 MP VALVE                                  Top Strainer                                                                Note Never Shorten the Riser Pipe installed inside the tank     AS0922MP CL Page 6    WATER HARDNESS TEST METHOD       Water to be tested should be taken from a tap after the water softener  Measure 10ml of water into plastic bottle supplied  approximately 1 3 full     Add one Yes No tablet to sample water  replace cap and shake until tablet  has completely dissolved    NOTE  do not handle Yes No tablet with fingers     The final colour to be obtained for soft water is green   Note  The shade of  green may vary   If the colour turns red  the water is above 20 mg l hardness   therefore another regeneration is recommended  However if the raw water  is very high in hardness it may not be possible to achieve a reduction in  hardness below 20mg l but the softener is still working correctly   Consult IBC Water for further clarification     Rinse plastic bottle after each test has been completed     When used as above  the tablets change the colour from green to red at a  hardness of approximately 20ppm based on a sample volume of 10mls     Other hardness test kits are available for more accurate testing eg     Hardness Tablets    Directions  Take a 50ml sample of water in a
59. wording  then flash the  software version and then reset the valve to the service position     AS0922MP CL Page 47    Order No   V3009  Description  WS1 Auxiliary  Micro Switch Assembly       Order No   V3009  Description  WS1 Auxiliary Microswitch Assembly                         Drawing No  Order No  Description Quantity  1 V3301 WS1 MICROSWITCH 1  2 V3302 WS1 MOLEX CONNECTOR 1  Not Shown V3303 WS1 MOLEX TERMINAL 3  3 V3304 WS1 SCREWS 4 40 X 5 8 2  4 V3305 WS1 RETAINING RING SS    1  5 V3306 WS1 WASHER ID 0 257 OD 0 640 1                      Slip the washer and retaining ring on to the end of the piston rod  Attach the microswitch to the drive  bracket using the screws  Attach the connector to the microswitch  Attach the terminals to wires and  connect     AS0922MP CL Page 46    Flow Rate arn     INJECTOR PERFORMANCE CURVES    BLACK  ORDER NO  V3010 1A  Metric Units       2 20      40 500             5       Pressure  kPa    VIOLET  ORDER NO  V3010 1C  Metric Units       9 4    10 200    40  EDJ      700          Pressure  kPa     WHITE  ORDER NO  V3010 1E  Metric Units                     M  ch    Fow Rate  lpm   m  o    A tt e       th    a  a                             0 5  100 200 200 400     oco BW      BIO 907  Pressure  kPa     Flew Rate  lprn     BROWN  ORDER NO  V3010 1B  Metric Units       20     200      40 500     70      900    Pressure  kPa     RED  ORDER NO  V3010  1D  Metric Units       Flow Rate                     100 20 300 400 50  00                   
60. y aligned to drive    bracket     i  Ensure PC board is correctly snapped on  to drive bracket        Motor not operating    a  Replace motor                                        b  No electric power at outlet b  Repair outlet or use working outlet  6  Control valve stalled in c  Broken drive gear or drive cap c  Replace AC adapter  regeneration assembly  d  Defective PC board d  Replace PC board  e  Broken drive gear or drive cap e  Replace drive gear or drive cap assembly  assembly  f  Broken piston retainer f  Replace piston retainer  g  Broken main or regenerant piston g  Replace main or regenerant piston  7  Control valve does not regenerate a  AC adapter unplugged a  Connect AC adapter  automatically when REGEN button b  No electric power at outlet b  Repair outlet or use working outlet  is depressed and held c  Broken drive gear or drive cap c  Replace drive gear or drive cap assembly  assembly  d  Defective PC board d  Replace PC board  8  Control valve does not a  Bypass valve in bypass position a  Put bypass valve in normal operation    Regenerate automatically but  does when REGEN button is  depressed    position          Meter connection disconnected    b  Connect meter to PC board              Restricted stalled meter turbine    c  Remove meter and check for rotation or  foreign matter       d     Defective meter    d  Replace meter       e     Defective PC board    e  Replace PC board          f  Set up error       f  Check control valve set up procedure      
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
ダイナミックベローズ Mシリーズ  AirLink UG-ASW224-1103 User's Manual  Behringer V-AMPIRE LX1200H/LX210 User's Manual  横浜市建築局 機械設備工事特則仕様書  Einbau-, Betriebs- und Wartungsanleitung  here - Solaxscooters  user guide  TP-Link TL-WR743ND V1 Declaration of Conformity  RedBeam Asset Tracking™ User Manual  "user manual"    Copyright © All rights reserved. 
   Failed to retrieve file