SmartLink Dementia & Patient Profiler INSTALLATION MANUAL
Contents
1. Alarm Door H2 Alarm Bed Ensuite Aor Door 1 Alarm Door 2 Alarm Bed 01 01 22006 01 01 42006 01701 2006 01 01 22006 01701 22006 0101 72006 01701 2006 01 01 22006 01701 22006 0170172006 01701 2006 01701 22006 00 27 39 00 27 39 03 49 10 03 49 10 00 00 06 00 00 07 00 00 08 00 00 09 00 00 09 01 20 36 01 20 36 01 20 46 Print Preview Graph Edit Device Settings The Device Properties are accessed either under the Device menu or by pressing the shortcut button found on top of the screen Patient Profiler Ver1 3 File Edit a View Help Device Properties Device Properties Get Events From Device Set Device TimerDakte Clear Device Memory Uploads Selecting a room number from the pull down list will bring up the details for a particular device including Device ID and Room Name Five menu Tabs found within the Device Properties window will allow the Device to be customized for any particular patient Note that the menu system found in the Dementia amp Patient Profiler Wall Controller is a similar but simplified version of the menu system found under Device Properties EEN Dementia amp Patient Profiler Installation Manual v1 34 doc The Menu Tabs listed are Timer Names Timer Settings Output 6 logic Security and Special Once the settings are complete they may be saved and transfer to the device by pressing the Save and Send buttons found on the bottom of the screen Plea
2. Using Shortcut Buttons Several shortcut buttons can be found on the top of the main menu These icons initiate the most commonly used features of the software such as Upload Download Clear Device Memory Patient Details and Device Properties Shortcut buttons Patient Profiler Ver1 3 File Edit Device View Help Ber 3 G gt iis Print Upload Patient Details Clear Device Memory Download Device Properties Editing Room Details The Patient Profiler Windows Software DPS 01 is capable of individually reading and writing information to and from multiple Patient Profiler units DPC 01 The software identifies the different units from each other by using the unique Device ID given to every Patient Profiler unit Establishing a link between the Device ID and the room number will be the starting point to setting up a system The Room Details are accessed under the Edit Menu Four fields allow Room Number Room Name Device ID and Notes to be recorded The key fields which must be filled out are Room Number and Device ID These two fields are critical when setting up a new device as they determine which device goes with which room The Room Name and Notes fields do not have to be filled out and are optional However the Notes field can be used to record installation date and any other changes that you make throughout the history of the product Hint If there is more than 1 patient per room you may put a letter after t
3. Bea ss Bed Emit r r 2 Room RoomPIR r r r 3 Ensuite Ensuite R r r Do Door Reed 5 Doo2 2 2 LG Hint An easy way to setup Device Properties is to send the Default device properties to a Device and then upload the settings to a corresponding room using the Get Settings feature Dementia amp Patient Profiler Installation Manual v1 34 doc 8 Appendix Specifications e Wall Controller Unit DPC 01 Size 140 x 130 x 40mm Connection RJ12 6Pin to Relay Module Box DB9 Pin Female to PC e Relay Module Box DPR 01 Size 110 x 160 x 72mm Power 12VDC 250mA max relays on Relay Relays are rated at 24V DC 1A Max Default Settings e Default Timers in Seconds Zone 1 Zone 2 1 300 Bed Exit 0 Note 0 disables the Input 2 390 Room PIR 0 Note 0 disables the Input 3 060 Ensuite PIR 0 Note 0 disables the Input 4 003 Door Reed 1 0 Note 0 disables the Input 5 003 Door Reed 2 0 Note 0 disables the Input e Default Time Zones Zone 1 07 30 Zone 2 19 30 e Default IO Logic Relay Output 6 Combo 1 1 2 3 4 Combo 2 1 amp 4 Combo 3 1 amp 5 Combo 4 1 Combo 5 1 Dementia amp Patient Profiler Installation Manual v1 34 doc ROOM DETAILS TN Name ID No Name ID Dementia amp Patient Profiler Installation Manual v1 34 doc DEVICE PROPERTIES No ID Names Settings Logic Dementia amp Patient Profiler Installation M
4. Profiler may or may not appear on the menu system see Section 4 System Setup via Keypad Although a majority of the programming may be done from the keypad there are certain functions that can only be done using the Dementia amp Patient Profiler Software such as changing Timer Names and Access Pins Other benefits of the software also include being able to quickly upload device settings and patient logs see section 5 System Setup via Software Figure 1 Patient Profiler Wall Controller DPC 01 LCD Data LED Be Active or Memory Full LED flashing Menu navigation buttons DB9 connector to Was PC during program _ 7 RJ12 connector to Relay Module Dementia amp Patient Profiler Installation Manual v1 34 doc Relay Module Box DPR 01 The Relay Module Box contains 5 optically isolated Inputs and 6 relay Outputs By default the primary Input 1 is the Out of Bed sensor normally closed and is used logically to enable each of the other Inputs i e all other inputs are disabled until Input 1 is triggered All inputs have an individual relay output which will operate after a programmed time has expired unless the patient returns to bed A sixth relay provides an additional output capability that can be programmed as any logic combination of input 1 and inputs 2 to 5 Figure 2 Relay Module Box DPR 01 Power 12V DC 1A Inputs Optically To Wall isolated Cont
5. Unchecked E Disable Full Memory Led Flash rm TUNE Bed N Closed Disable Beep s N Open Room N Open MO pen Ensuite N Open Door 1 N Open SECUS Door 2 N Open Save Dementia amp Patient Profiler Installation Manual v1 34 doc Upload Device Log amp Device Settings Using the upload function of the software a user can upload and save the device settings and device Log from the Profiler Unit onto a PC The Upload function is accessed either under the Device Menu or by pressing the shortcut button found on top of the screen Patient Profiler Ver1 3 File Edit View Help Device Properties Get Events From Device Set Device Time Date Clear Device Memory Uploading Device Log When the LOG file reaches 900 entries the Red LED on the Wall Controller Keypad will flash momentarily every 3 seconds This is an early warning that the device is running out of memory and the LOG needs to be uploaded to the host PC and the memory cleared Simply connect the device to the host computer and click on the Upload icon If ignored the memory will continuously record events such that only the last 1000 records are automatically retained If the Device ID of the unit that is Upload data from device SL 11050047 being uploaded matches the Device Room Numbers Device SL 11050047 ID of a Room Number then the oes eae ee esau Details of the Room are displayed ee A and the Data stored und
6. 0 00 08 00 00 09 00 00 09 01 20 36 01 20 36 01 20 46 Print Preview Graph 7 Quick Setup Guide Using Software 1 Enter Room Details Room Details Room Number Optional items are Room Name and Notes Eu Must enter Room Number and Device ID Device Details Device Id 1050047 Remove T Close Patient Details II Enter Patient Details Personal 5 First Must enter Surname First Name and Name tizer gt John gt Room Number Address o Optional items Address Phone Contact Phone Name Contact Phone Contact Address Room Name amp Notes Contact Mame ee Address Humber Room Mame DE Hotes Dementia amp Patient Profiler Installation Manual v1 34 doc III Enter Device Properties Select the Room Number from the Pull down menu Fill in the details for Timer Names Timer Settings Output 6 Logic Security and Special Press on Save button Connect the Dementia and Palient Profiler unit to the PC using a standard DB9 serial cable Press the Send button The Profiler Unit will Beep to indicate settings have been transferred see Page 14 to 18 for Default settings Device Properties Device Details Room Humber Room Mame 4 Device Id Timer Hames Timer Settings Output 6 Logic Security Special Timer Mame Timer Description 1
7. SMART LINK Tomorrows Technology Today SmartLink Dementia amp Patient Profiler MA 2 9 on Mem Full O 9 O Qo 0 550 m ni INSTALLATION MANUAL Dementia amp Patient Profiler Installation Manual v1 34 doc Table of Contents L Equipment List 2 2 Overview 3 Introduction 3 Wall Controller Unit DPC 01 3 Relay Module Box DPR 01 4 Software Requirements 5 Cable Requirements 5 Power Supply 5 3 Wiring system pinouts 6 4 System Setup via Keypad 7 Patient Profiler Wall Controller DPC 01 Commands 7 Limited Access Menu Default Pin Code 1234 7 Full Access Menu Default Pin Code 4321 7 Full Access Menu Descriptions 8 5 System Setup via Software 9 Software Installation 9 Reading Device ID 9 Setting COM Port 9 Using Shortcut Buttons 10 Editing Room Details 10 Edit Patient Details 12 Edit Device Settings 13 Timer Names 14 Timer Settings 15 Output 6 Logic 16 Security Settings 17 Special Settings _ 18 Upload Device Log amp Device Settings 19 Uploading Device Log 19 Uploading Device Settings 20 Graphing and Printing Data 21 7 Quick Setup Guide Using Software __ 22 Enter Room Details 22 II Enter Patient Details 22 Enter Device Properties 23 8 Appendix 24 Specifications 24 Default Settings 24 9 Notes 25 EN Dementia amp Patient Profiler Installation Manual v1 34 doc 1 Equipment List The SmartLink Dementia
8. To trigger Strobe Light Siren Software Requirements The Dementia amp Patient Profiler Software DPS 01 may operate on any IBM compatible PC running Windows 2000 or Windows XP Serial communication may be established using Com Ports 1 to 8 via a standard DB9 serial cable Device logs and settings may be uploaded to the PC with the option to clear the device memory Cable Requirements The Dementia and Patient Profiler System comes complete with a 5m connection cable between the Wall Controller Unit DPC 01 and the Relay Module Box DPR 01 However if the need arises to increase the distance between the Wall Controller and the Relay Module Box the maximum distance of 15m should not be exceeded Cable required for extensions is RJ12 6 Pin in line Power Supply The System will operate from either 12VDC un regulated supply or a regulated 12VDC power supply If any external equipment such as a is to be connected in parallel with this power supply it is recommended that a regulated power supply be used Please ensure that the current requirements are within the maximum specified Dementia amp Patient Profiler Installation Manual v1 34 doc Wiring system pinouts Dementia amp Patient Wall Controller Profiler Software DB9 RS232 MAX 15 m Laptop Computer RJ12 6 Pin MAX 15 m Bed Exit Sensor Hoom PIR 12 Volt 1A Regulated Power Source Ensuite PIR Door Reed 1 l
9. amp Patient Profiler package should contain the following e Patient Profiler Wall Controller Unit DPC 01 e Relay Module Box DPR 01 e Demonstration Software Ver1 4 DPS 01 Full Version Purchased Separately 5m RJ12 6Pin cable to connect wall controller to relay module e Installation Manual Dementia amp Patient Profiler Installation Manual v1 34 doc EN 2 Overview Introduction The SmartLink Dementia amp Patient Profiler System provides a convenient method of monitoring and logging patient activity The system is comprised of three components the Wall Controller Unit DPC 01 the Relay Module Box DPR 01 and the Windows Software Ver1 3 DPS 01 Typically the Wall Controller unit provides a simple access point where a patient s activity may be reviewed and changes made to their profile The term patient profile is used to describe a patient s normal activity In the event that a patient strays from the set profile an alarm is raised and the event is logged in memory The ease of use and simplicity of the Dementia amp Patient Profiler make it an ideal system for monitoring and controlling patient activity Wall Controller Unit DPC 01 The Wall Controller of the Dementia amp Patient Profiler is primarily intended for use by the Nursing Staff to view a patients log and also by System Administrators to review and alter a patient s profile Depending on the user certain functions of the Dementia amp Patient
10. an existing room with different Device ID Room Door 1 Alarm Door H2 Alarm 00 00 08 00 00 09 00 00 09 01 20 36 01 20 36 01 20 46 13 26 46 170 Save Properties Device ID Mismatch 01 01 2006 0170172006 0170172006 0170172006 0170172006 0170172006 2209 2006 dm dmn There is a mismatch in Device ID Are vou sure to save the device settings into room 1 Mo Dementia amp Patient Profiler Installation Manual v1 34 doc EN 6 Graphing and Printing Data To view the Patient History go Patient History to View and select Patient Listing Simply double click on a Patient to reveal the Patient o History You choose to m 311233334 Hace Mr Citizen a diabetic show all the history ora Address 1 Palermo Sreet particular upload date Patient Details Show Al Event Input Date Time To view a graphical representation of this data simply click on the Graph button or click on the Print Preview button to print Patient Progress Door 1 Room Alarm Door 2 Alarm Bed Ensuite Door 1 Alarm Door H2 Alarm Bed 21 03 2006 0170172006 01201 22006 0120122006 0170172006 01201 22006 0170172006 0170172006 0170172006 0170172006 0170172006 0170172006 0170172006 0170172006 0120122006 Log Output EN Dementia amp Patient Profiler Installation Manual v1 34 doc 8 08 25 00 00 10 00 00 11 00 27 39 00 27 39 03 49 10 03 45 10 00 00 06 00 00 07 0
11. anual v1 34 doc SMART LINK Iomorrows Tecbnology Today Copyright SmartLink International Pty Ltd July 2008 Level 1 304 308 New St Brighton VIC 3186 Australia Tel 61 3 9596 0770 Fax 61 3 9596 8195 Email smartlink smartlink com au Web Site www smartlink com au To the best of our knowledge the information contained in this manual is correct at the time of print SmartLink International Pty Ltd reserve the right to make changes to the features and specifications at any time without prior notice in the course of product development EB Dementia amp Patient Profiler Installation Manual v1 34 doc
12. d 2 Ce Dementia amp Patient Profiler Installation Manual v1 34 doc EN Timer Settings Under the heading of Timer Settings there are two important categories Time Zone 1 and Time Zone 2 These two time zones if used will break up the day into two sections Day Mode and Night Mode If time zones not required simply set the Time Zones to 00 00 and assign timer values to Zone 1 The two Seconds columns next to the Timer Names indicate the time to wait before activating a corresponding relay Timer values can range from 000 to 999 seconds 16 5 minutes During normal operation i e patient is in bed inputs 2 to 5 will be deactivated and will not respond to any inputs Once relay 1 Is triggered due to the patient being out of bed then all the relays are active and if any of the inputs are triggered then the corresponding relay will activate based on the time setting The timers begin the countdown the instant the patient gets out of bed and operate independently from one another i e the timer setting on one input does not effect the timer setting on another input For example if a patient were to get out of bed and simultaneously trigger all inputs then relay outputs 4 and 5 will immediately latch after 3 seconds followed by relay 3 after 57 seconds followed by relay 1 after 240 seconds and finally by relay 2 after 90 seconds This is based on the default settings shown below These settings are acc
13. device settings are transferred from a PC to the Wall Controller Unit the Computer Time and Date is also transferred 6 Test Outputs The relay outputs may be individually tested with this function An on board LED indicates the status of each relay Pressing 1 will toggle relay 1 on off with the status shown on the display On pressing Clr all relays will turn off again r Test Inputs By activating the detector the status of the Input will be displayed 8 View Device ID To View Wall Controller Unit ID eg SL 0904001 9 Device Options To activate Memory LED On Off activate Beeper On Off Options amp Select Input Polarity C Exit Menu Press the clr key to Exit Menu Dementia amp Patient Profiler Installation Manual v1 34 doc 5 System Setup via Software Software Installation Insert the Dementia amp Patient Profiler CD into the CD ROM drive The software should automatically begin installation If for any reason installation does not commence double click on My Computer then select the CD drive containing the software Double click on the setup exe Follow the setup instructions to complete the setup process In some instances during installation you may be prompted to select between two identical files Choose the file that is the newest After the program is installed you may run it by going to Start and then by selecting Programs Under Programs you will see the newly installed program Patient Pr
14. er the Time Date 5 corresponding Patient name 000 Bed 00 00 10 0101 2006 Of Dans tt 20 00 12 11201 af During the Upload process a Bar I Upload Progress will appear showing the progress of u the upload gt KmIcKc If during the upload procedure you receive the following error message please make sure the 00 00 09 01701 2006 device is properly connected and a ae jou z e that you can see the Device ID AI 01 20 36 0101 2200 the bottom left hand corner Bed 01 20 46 0120122006 2 1 Upload Events from Device Ed amp Get Settings Device Connected Dementia amp Patient Profiler Installation Manual v1 34 doc Uploading Device Settings Pressing the Get Settings button on the Upload window will display the current settings of the device in the Device Properties window The user is then given the option of either saving the settings to an existing room or saving to a new room Upload data from device 51 11050047 Room Number 1 Device SL 1105004 Room Mame Recovery Room 1 Input Name Time Bed 00 00 10 1 01 2006 Door 1 00 00 11 012012006 00 27 39 01 01 2006 Saving Device Alarm 00 27 39 01 01 42006 Door 2 03 49 10 01 01 2006 Settings using the Alarm 03 49 10 01 01 2006 Get Settings Bed 00 00 06 01 01 2006 button Ensuite 00 00 07 01 01 42006 A warning message will be displayed if the settings are to be saved into
15. essible via the Profiler Keypad The settings may be viewed and changed via the keypad Device Properties Device Properties Device Details Room Number Room Mame Timer Settings Default Device Id k Default Settings Time Zone 1 Time Zone 2 7 30 19 30 Time one 1 Time one 2 300 0 07 30 md 19 30 E Timer Mame Seconds Seconds 2 390 0 iE 300 in 3 60 0 390 f 0 E 4 3 0 3 Ersu 0 0 4 bon 32 2 3 0 EN Dementia amp Patient Profiler Installation Manual v1 34 doc 5 3 EY i Output 6 Logic The Output 6 Logic tab controls the AND logic for the activation of the sixth relay on the relay board Simply click to check the boxes that you want to activate the sixth relay For example if the Patient gets out of bed triggering the Bed sensor and opens the door triggering the Room PIR and the Door 1 reed switch then Relay 6 will activate based on Combination 2 These settings cannot be changed via the Profiler Keypad Device Properties Device Properties Device Details Room Number Room Mame Output 6 Logic Default Device Id Default Settings Comb 1 1 2 3 4 Combination 1 m m Comb 2 1 4 Combination 2 Comb 3 1 5 Combination H3 Comb 4 1 Combination 4 Comb 5 1 Combination 5 Save Dementia amp Patient Profiler Installation Manual v1 34 doc Security Settings The Security tab al
16. he room number to indicate that there is more than one Dementia amp Patient Profiler Unit in that room Single Room Listing with Multiple Devices Room Name Room Notes Recovery Room 1 1a Test Room 1a oL bebebebe 16 Test Room 16 5L 43434343 Dementia amp Patient Profiler Installation Manual v1 34 doc Room Details Room Details Room Humber Room Hame IR ecover Room 1 Device Details Device Id Room Details L 11 050047 x After entering the room details you may view a summary of the records by selecting View and then selecting Room Listing Double clicking on any of the records will bring up the Room History window which summarises all the activity for that room Room History Room Details Room Number 1 Device ID SL TTUSUCH E Room Name Recover Room 1 Device Name Last Upload Upload Date Upload Time Patient Name NoofEvents Room History 21709 2006 09 09 26 Citizen ohn EN Dementia amp Patient Profiler Installation Manual v1 34 doc Edit Patient Details The Patient Details are accessed under the Edit Menu Nine fields allow Surname First name Address Phone Contact Name Contact Phone Contact Address Room Number and Notes to be recorded The key fields that must be filled out are the First and Last Names The Room Number field may be left as none or assigned to a Room if known The Name and Room Number fields are critical as they make a con
17. l Door Reed 2 gt gt lalla O lal be lal lal he gt III O Inputs To Wall ES pE3 ES BS EJ 6 Pin Relay Module Box Relay Relay Relay Relay Relay Relay Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 O KO 24 1A rated relays for controlling lights or sirens or interface to Monitoring system Figure 4 System Connections and Pin outs Dementia amp Patient Profiler Installation Manual v1 34 doc 4 System Setup via Keypad Patient Profiler Wall Controller DPC 01 Commands The LCD display found on the Wall Controller Unit will normally display the current Date and Time During this period the unit will accept up to 2 PIN numbers By entering either the limited or full access PIN the user may toggle through a menu system that corresponds to the pin number While in the menu system unit will default back to requesting PIN again if no key is pressed within 30 seconds Limited access enables a Nurse to view but not edit parameters The Menus are described in the following table Limited Access Menu Default Pin Code 1234 0 DISABLE ENABLE INPUTS RED LED INDICATES UNIT IS ACTIVE a views VA 2 View I O Logic Exit Menu Press clr to Exit Menu The menu may be browsed using the up down keys and selection made using the OK key Alternatively if the Item number is Known
18. lows the user to change the default user codes Note that the default Limited Menu Access code is 1234 and the default Full Menu Access code is 4321 As in all the other menu tabs it is possible to save the settings and send them to the device using the RS232 cable These settings are NOT accessible via the Profiler Wall Controller They may only be viewed and changed using the software Device Properties Device Properties Device Details Room Number Room Mame Security Default Device Id pu SSS Default Settings Pint 1234 Fin 1 Fin 2 1 234 4321 Ful Menu Access iv Full Menu Access Pin2 4321 Full Menu Access Hotes E Dementia amp Patient Profiler Installation Manual v1 34 doc Special Settings The Special settings menu is mainly used to configure the Input Polarity of the 5 sensors i e Normally Open N O or Normally Closed There are also two other settings that allows users to enable or disable the onboard beeper and the Memory full LED Once all the settings are correct click on Save and then Send to device The changes made using the PC software will be instantly reflected in the Patient Profile unit These settings are accessible via the Profiler Keypad The settings may be viewed and changed via the keypad Device Properties Device Properties Device Details Room Number Room Mame Special Default Device Id Default Settings Full Memory Led Flash Unchecked Disable Beeps
19. nection between the Patient and the Room Number he remaining fields do not have to be filled out The Notes field may be used to store important information about the patient such as any medical conditions Patient Details Personal urname First Mame ohn Address 1 Falerma Sreet Phone 191 1233334 Contact Patient Details Phone Adam Citizen brother 1045343455345 Address 1 Toscana Drive Humber Room Mame x Recover Room Hotes i Citizen iz a diabetic Remove Save Close Once all the patient details are entered you may view a summary of the records by selecting View and then selecting Patient Listing Double clicking on any of the records will bring up a new window on the right hand side of the screen labeled Patient History This window will contain a summary of the patient s details and also a log of their activity The log may be viewed in a graphical representation or be printed out by pressing the Graph and Print Preview buttons respectively Dementia amp Patient Profiler Installation Manual v1 34 doc Patient History Patent Details Mame Citizen John Contact Adam Citizen Room 1 Phone 045343455345 Phone 811233334 Motes Mr Citizen a diabetic Address 1 Polermo Sreet Show I z 21 08 2006 08 08 25 000 01 01 2006 00 00 10 Patient History 001 Door 1 01 01 2006 00 00 11 002 004 005 Dr 005 009 O10 011 012 Acorn
20. ofiler The Dementia and Patient Profiler Program will operate for 30 openings Loads as a Demonstration package then automatically shut down permanently until a special security code is provided After this time the software must be purchased and enabled from Smartlink International Reading Device ID To ensure accurate logging of patient data each controller has a unique device ID Number which is printed on the back of the Wall Controller Alternatively if the controller is physically connected to the computer then the device ID will be automatically read by the program and displayed on the lower left hand corner of the screen If you are setting up a database without connection to each of the devices then you will need to know the device ID when setting up Room Details Setting COM Port When selecting a COM Port please ensure that the port selected is available for use otherwise an Error message will be displayed Selecting the Retry button on the error message will allow the software to scan the next port for availability Patient Profiler Ver1 3 mim Edit Device View Help COM Port come Selection to 5 coms Lom Alarms Uploads ome Com Cama Search for available Com Pork 5 Mot Available port by pressing Retry Please Ensure Port is Available and nat in use by Another program Dementia amp Patient Profiler Installation Manual v1 34 doc
21. roller Relay LED indicators 3 Relay Outputs Normally Open Normally Closed Each of the 5 inputs are allocated a delay time expressed in seconds ranging from O to 999 Provided the input is triggered within a valid Time Zone a corresponding output Relay will trigger If a Timer period overlaps a Time Zone Day or Night mode then on the change of Time zone the timer is restarted at O Each time an Input Timer expires a LOG is generated with time amp date stamp If the combinational logic is right for operation of output 6 then this is also recorded in the LOG An automatic reset will occur on all inputs if the Bed Input restores to normal regardless of the Time Zone By default the 5 inputs are labeled as shown e Input 1 Normally Closed Bed Exit Input 2 Normally Open Room PIR Input 3 Normally Open Ensuite PIR Input4 Normally Open Door Reed 1 e Input 5 Normally Open Door Reed 2 Dementia amp Patient Profiler Installation Manual v1 34 doc EB Relay Outputs 1 to 6 use low voltage N O Normally Open and N C Normally Closed contacts rated at 24VDC 1Amp and if required to operate lighting then a further relay or contact can be used for the 240VAC lighting circuit Figure 3 Example of a basic System Setup Wall Controller Bed with sensor Door Reed Switch 1 Dementia amp Patient Profiler Relay Module Box To Nursecall System i e SmartWire
22. se note that a warning message will be displayed if there is a mismatch in the Device ID Connection to the Device with a DB9 serial cable is essential during the send procedure Error Message displayed when ID Mismatch occurs between Hardware and Software Yes Ma The Default room number is configured with the Default settings If required these settings may be changed and saved for later use Timer Names Device ID Mismatch Da vou still want to download the device properties You may change or add to the Timer Names and Descriptions Once changes are made you may save and send the information to the Profiler using the Send button The changes made on the software will be reflected in the Patient Profiler Wall Controller Unit Note that only the Timer Names are stored on the Profiler Unit and they cannot be changed The Timer Descriptions are not stored on the Profiler Unit and are provided only for the benefit of the software user Device Properties Device Details Device Properties Room Number Room Mame Timer Names Default Device Id Default Settings Timer Hames Timer Settings Dutput 6 Logic Security Special Timer Name Description Timer Mame Timer Description 1 Bed Bed Exit 1 Bed BedEsi 2 Room Room PIR 2 Room Room PR 3 Ensuite Ensuite PIR 3 Ensuite Ensuite PIR 4 Door 1 Door Reed 1 Door 1 Door Reed C 5 Door 2 Door Reed 2 SiDor 2 Doo Ree
23. then this provides a direct shortcut to the selection Full Access Menu Default Pin Code 4321 DISABLE ENABLE INPUTS RED LED INDICATES UNIT IS ACTIVE gt 71 View Log on screen display of log of Timers 1 View Timers 2 edt Timers 73 Edit Time zones 74 Load Defaults See Append 3 View I O Logic for Relay Output 6 only 4 Set Time samme S SOSO KK Tetoupts Memory LED on off EM Fu Beeper on off Input Polarity Exit Menu Press clr to Exit Menu Dementia amp Patient Profiler Installation Manual v1 34 doc EN 8 vi li Device I Full Access Menu Descriptions 0 Disables Enables the Inputs In the event of a patient being moved to theatre or another room or being discharged T View Log Enables the current log to be viewed without downloading information to the computer Windows Software 2 Timers Edit Timers provides access to sub menu where you can either view or edit Timers and Time Zones For convenience the DPC has the facility to edit the timer values as may be required with over regular alarms on a particular patient 3 View I O Logic For Relay 6 Output is setup on the computer and transferred to the Wall Controller unit DPC 01 on initial setup The actual logic condition however can be viewed but not changed with this function 4 amp 5 Set Time and Date Note that when
Download Pdf Manuals
Related Search
Related Contents
≪平成26年度≫ 長野県課題図書・全国課題図書一覧 1 類(長野県課題 DinaBase - Laboratoire medident Manuel d`installation Veneco Ventilation Systems Lithonia Lighting TZL1N L96 6000LM FST MVOLT 40K 80CRI WH Installation Guide Digitus HDMI 1.3 1m d`information en Europe Peavey MD Monitor Mixer User's Manual Entorno Gráfica KDE Copyright © All rights reserved.