Home

0.07.B.0029 D5-Evo Installation Manual-10Jul2012-NG

image

Contents

1. Start on the right FI GURE 27A Gate Pedestrian closed opening TEK screw self drilling and tapping screw FI GURE 27B mounting holes FI GURE 28 3 When joining two lengths together simply butt each section firmly together to ensure the correct pitch Butt firmly together FIGURE 29 Mount the origin marker 1 Close the gate completely FIGURE 30 2 Mount the origin marker to the rack a minimum of 500mm from the origin sensor Refer to Figure 31 isometric view A or plan view B It is possible to make the distance between the marker and the Origin sensor much greater than 500mm However if using the pedestrian opening facility although the position of the marker will not sensor affect the width of the pedestrian i Ri closed opening it is preferable to have Briain the marker mounted inside of the marker pedestrian opening point sensor FIGURE 31 page 25 10 LL 12 For steel rack mount the origin marker onto the rack using the bracket provided Weld the bracket to the rack Bolt the origin marker onto the bracket using the fasteners provided With the RAZ rack the origin marker mounts directly on top of the rack without a bracket Drill mounting holes directly into the rack and bolt
2. Foundation plate Foundation plate 32 50 Flat bar welded to Raised foundation foundation plate and rail Indudes 3mm dearance required between rack and pinion FIGURE 10A Nylon angle rack above pinion FIGURE 10B Nylon angle rack below pinion page 17 Foundation plate installation 1 The foundation plate can either be set into a concrete foundation as in Figure 11 or bolted down onto an existing concrete plinth as in Figure 13 Option 1 Concrete foundation 2 Assemble foundation plate with anchor brackets as shown Ensure that the M10 gearbox mounting bolts are properly tightened Cable conduits must be installed before pouring the concrete see next section FIGURE 11 When using a concrete foundation it is recommended that the foundation plate is welded to the rail track of the gate using short length of flat bar as in Figure 12 This makes it possible to complete the whole mechanical and electrical installation without having to wait for the concrete to a on set After completing the installation the concrete can be poured and the operator left in the manual mode until the concrete Flat barwelded o has set foundation plate and rai FIGURE 12 page 18 M10 nut Ne M10 washer M10 gearbox l 2l mounting bolts Option 2 Existing concrete plinth 3 If bolting onto an existing concrete plinth place the foundation plate down i
3. Q Aux Q Status T Com N Aux l0 D oH MN D H E D 1 D i pH D E i Motor eu Motor D TU iz zavi E NENE ali ANA 301 L4 FI GURE 40 page 29 PT3 Wiring diagram for opening safety beam Opening safety beam 7 w z A 0 lt 12V 24V ua Charge AN SOA FIGURE 41 page 30 sing diagram for external radio receiver and loop detector E all Light Ea Light Senee Encoder Origin Sate Common Aux 12V Out Close 0 Sati Loop and loop detector Li Loop detector iani External radio receiver QO Status ton Aux 10 _ Motor An Motor o 12 V oys a Charger Remote control circuitry w 1 Refer to diagram only if external receiver is being used and not the onboard receiver disable onboard receiver Menu 11 FI GURE 42 page 31 PT5 Wiring diagram for other inputs Holiday lockout keyswitch keypad normally CLOSED Intercom pushbutton normally OPEN Pedestrian keyswitch keypad normally OPEN Pillar light pushbutton normally OPEN Status LED IT Ta TE Light _ Light LLL Encoder Safe Common Aux 12W Out Q Close O sais PISO H1 Aux Motor DI Motor 42 y 12 Va aur Charger ARTA GOA FIGURE 43 as supply battery charger and pillar l
4. One of the buttons is used as a shift button to allow the other Cd buttons to be used again in combination with this button In other words the user will press and hold the shift button before pressing one of the other buttons to create a new button e The shift button cannot be used as a button on its own it must always be used in combination with the other buttons Benefits of the shift button system e Use of the shift button system allows a three button transmitter to gain an extra button and operate four functions and likewise a four button transmitter gains two extra buttons and can operate six functions e Another benefit of using the shift button system is that it requires both hands to operate the two button combination This prevents the user from accidentally enabling sensitive functions such as Holiday Lockout on the controller Each transmitter learned into the system is assigned a unique transmitter ID Press valid button If the remote controls menu has been locked as discussed later only by pressing a button of a transmitter learned into the system can the remote controls menu be accessed Add remote Any button can be set to control the trigger pedestrian free exit Holiday Lockout or courtesy light control Aux inputs When adding transmitters it is recommended that a record be kept of the ID number allocated by the system to each respective transmitter and the person to whom the transmitter is given
5. 5 2 Pre open delay 5 3 Pre close delay 5 4 Opening speed 5 5 Closing speed 5 6 Ramp up distance 5 7 Ramp down distance 5 8 TRG stop distance 5 9 IRB stop distance 5 10 Crawl distance 15 6 Infrared beams I1 6 1 PIIRAC control 6 1 1 PIRAC status 6 1 2 Stop on open 1 2 1 Stop on open status 6 1 2 2 Stopping distance 6 2 IR beam test 6 2 1 Status 6 2 2 Test beam 6 3 IRBO IRBC on closing 6 4 IR beam alarms 6 4 1 Ambush alarm 6 4 1 1 Ambush alarm status 6 4 2 Break in alarm 6 4 1 2 Broken IRB time status 6 4 3 Alarm output 7 Pedestrian 7 1 Pedestrian open position 7 2 Pedestrian Autoclose time 7 3 Pedestrian pre open delay 7 4 Pedestrian pre close delay N N 8 Courtesylight E 81 Courtesy light timer 8 2 Light profile 8 2 1 Courtesy light 8 2 2 Pre flash A 8 2 3 Pre flash B 8 2 4 Pre flash C page 38 9 ChronoGuard 9 1 Time and date 9 2 Time periods 9 2 1 Add Time period 9 2 1 1 Auto function 9 2 1 2 Time bar 9 2 2 Delete Time period 9 2 3 Edit review Time periods 9 3 Exclusions 9 3 1 Add exclusion 9 3 1 1 Auto function 9 3 1 2 Time bar function 9 3 2 Delete exclusion 9 3 3 Edit review 9 4 Delete all Time periods and exclusions 10 General settings 10 1 Operating standard 10 2 Reset options 10 2 1 Factory defaults 10 2 2 Delete all remotes 10
6. CENTSYS N e 19 20 21 22 23 24 25 26 27 Contents Mechanical Setup Electrical Setup Commissioning and Handover IMPORTANT SAFETY INSTRUCTIONS Declaration of conformity General description Lightning protection Theft protection Specifications Physical dimensions Technical specifications Fuse protection Icons used in this booklet Product identification Required tools and equipment Preparation of site Cabling requirements Lubrication Operator installation Electrical setup Wiring diagram for closing safety beam Wiring diagram for opening safety beam Wiring diagram for external radio receiver and loop detector Wiring diagram for other inputs Mains supply battery charger and pillar light connections Earthing for effective lightning protection Commissioning the system Setting the gate limits How to set up additional features on the D5 Evo controller Menu navigation map Controller features Factory defaults schedule Description of terminal functions Diagnostics Diagnostic LEDS Gate status LED LCD display Buzzer feedback Fault finders guide Manual operation Manual release operation Manual release latching Installation Handover page 1 page 2 page 2 page 3 page 5 page 6 page 6 page 6 page 7 page 7 page 7 page 8 page 8 page 9 page 10 page 11 page 14 page 15 page 16 page 28 page 29 page 30 page 31 page 32 page 33 page
7. External gate status indicator A low current output signal An output terminal which provides a low current drive approx 4 5V DC 20mA to a LED which can be used to indicate the gate status remotely If more than three LEDs are required it is necessary to fit the CP78 multi LED driver card For more details on the feedback about the status of the gate provided by the status LED refer to Section 24 Activates the pillar light relay A normally open potential free input Momentarily connecting this input to Com will cause the light relay to energize for a period of time as set in the courtesy light timer menu If the connection is made for a period exceeding three seconds the pillar light relay will latch and remain latched indefinitely until a new momentary connection to Com is given Free exit input A normally open potential free input Momentarily connecting this input to Com will cause a gate which is closed or closing to open or re open If the gate is open or opening the signal has no effect other than to reset the Autoclose timer if selected Free exit FRX never initiates a closing cycle The only way to close a gate if only the FRX input is used is to activate the Autoclose feature on the controller The common termination point All trigger signals etc have their return path to one of the Com terminals page 53 Ped Trg Lck Stp Safety Open Safety Close Aux 12V Out Pedestrian opening input A n
8. Free exit FRX Holiday Lock Lck Courtesy light control Aux page 47 Time barring of a CENTSYS code hopping transmitter is specified at the time of coding the transmitter into the system Once an RF input is defined as time barred any time barred transmitter associated with that input will be time barred during the relevant Time period If a physical or RF input is currently time barred any attempt to activate it will be acknowledged by a short beep of the onboard buzzer The input however will not activate Exclusions Exclusions are used to prevent scheduled Time periods from occurring at Specific times e g public holidays While time barring can be used to achieve a similar end exclusions can also be used to exclude time barring itself Each exclusion consumes one Time period Exclusions have the highest precedence followed by time barring and then Auto activations auto function Menu 10 General features Operating standard Regional operating standards can be set Applying this setting will automatically configure the controller settings to conform to the specific regions standard e g UL325 or CE Reset options The controller settings can be reset through the reset options menu Various reset options are available Factory defaults All settings will be restored to the default values dictated by the operating standard profile that is currently selected All remote controls and gate limits will no
9. This is necessary should selective deletion be required at a later stage Delete remote Transmitters can be deleted at any stage according to one of the following methods Delete remote by ID Each transmitter can be deleted individually according to its unique ID To facilitate this a record of the ID and the person to whom the ID has been assigned must have been made at the time of learning the transmitter into the system The transmitter is not required for this operation page 49 Delete remote button The operation of a button of a particular transmitter can be cleared For example it allows the Holiday Lockout function set on one remote button of a transmitter to be cleared without affecting the other operations that the same transmitter performs The transmitter is required for this operation Delete remote by button Use this procedure to remove the transmitter from the system All button functionality will be removed The transmitter is required for this operation Delete Not Present Allows for transmitters that have not been used within a selectable time period to be removed from the system The time period can be set from one hour to seven days in one hour increments Delete all remotes Clears the entire memory All transmitters will be removed Edit remote button Change the function of one button to perform another function For example button one s function is to open the gate completely To change this use t
10. through these cable entry points page 20 FIGURE 15 M10 nut DD is M10 n washer FIGURE 17 Mount the rack The rack must be securely mounted to the side of the gate It j parallel must be parallel with the gate rail to rail and there must be a 2 3mm gap 7 between the teeth of the pinion NS FI GURE 18 e Follow this procedure whether mounting steel RAZ or nylon angle rack e Refer to the sections that follow for specifics about the mounting of each type of rack 1 Before mounting the rack raise the operator an additional 3mm FI GURE 19 2 Put gearbox into manual mode Refer to Section 26 for complete instructions FI GURE 20 page 21 3 Start with the gate either fully open or closed Level this end of the rack and fix 4 Place the one end of the first section of rack on the pinion Let it mesh fully 5 Level the other end and fix that end to the side of the gate FIGURE 21 amp Refer to the sections that follow for instructions on how to fix the different types of rack wba atta 6 Slide gate halfway along the first section just resting on the 7 Level the unsecured end ensuring that pinion the rack is resting on the pinion not pressing down 8 Before fully fixing each section of rack slide gate backwards and forwards along the section checking that the rack is only resting on the pinion not pressing down 9 Continue
11. 5 PCM status On Off PCM force 10 Pre open delay time mm ss 00m 00s Pre close delay time mm ss 00m 00s Opening speed m min 10m min Closing speed m min 10m min Ramp up distance m 0 1m Ramp down distance m 0 1m TRG stop distance m 0 1m IRB stop distance m 0 1m Crawl distance m 0 01m Torque limit A 4A Menu 6 PIRAC control On Off Stop on open On Off Stopping distance m Om IR beam test On Off Test beam IRBC IRBO both page 51 Default UJ A w W Off 00m 15s 00m 03s Off 30 00m 00s 00m 00s Max Max 0 2m 0 2m 0 25m 0 17m 0 03m 15A Off Off 0 1m Off I RBC Maximum Max Max 255 04m 00s 04m 00s 100 O1lm 05s 01m 05s Max Max 10m 10m lm lm lm 15A IIM Parameter Description Unit Minimum Default Maximum 00h 01m 00h 01m B CL SC XIO LED Menu 6 continued Ambush time 04h 00m Alarm output Menu 7 PED Autoclose 00m 00s 00m 05s 04m 25s PED pre close delay mm SS 00m 00s 00m 00s 04m 00s Menu 8 Light profile CL PFA PFB PFC CL Menu 9 not applicable Menu 10 Round test button On Off On Menu 11 Autolearn On Off Off Onboard receiver On Off On Limited by gate length Legend B Onboard buzzer PFA Pre flashing mode A C Condominium mode PFB Pre flashing mode B CL Courtesy light PFC Pre flashing mode C D Deadman Control Mode R Reversing Mode IRBC Closing safety beams S Standard Mode IRBO Opening safety be
12. Holiday lockout input activated Green Lck light should be on IRBC IRBO IR beams inputs activated IRBC gate will not close once open IRBO gate will not open once closed Green IRBC IRBO lights should be on check cabling and Aux 12V Out e Latching input on Trg or FRX Gate does not move l Both Trg and FRX lights must be off for gate to operate e Check for an auto activation auto function on FRX and Trg inputs Refer to diagnostic screen with matrix showing different auto activations auto function and time barring functions on the different inputs e Check the battery condition with procedure A Low battery voltage condition later in this section If status light flashes four times or there is a Max Collisions indication on the LCD display then the operator is in Multiple Collision Mode If required check with procedure B False collision detection later in this section f the problem persists the main controller might be faulty Check the battery condition with procedure A Low battery voltage condition especially if the status light flashes three times or there is a Battery Low indication on the LCD display Check for false collisions with procedure B False collision detection later in this section status light could also flash Gate moves a short four times if the number of detected collisions exceeded the distance and then stops Collision counter feature value and LCD indicates Ma
13. and light industrial operator designed to open and close sliding gates weighing up to 500kg A custom designed gearbox moulded from robust engineering polymers coupled to a powerful 12V DC motor provides fast and reliable automation for entrances to homes and small housing estates The system operates off a 12V battery housed inside the operator using a switch mode charger to maintain the battery in a fully charged state The battery provides critical power failure protection A solar supply can be used as an alternative energy source to charge the battery Gate travel limits are managed by an opto electronic system comprising a gate mounted origin magnet and an internal rotary encoder This system yields precise and repeatable control over gate position Advanced features of the D5 Evo logic controller include Interactive graphical user interface via a backlit LCD display Automated setup of gate endpoints limits Fail safe collision detection and auto reverse adjustable sensitivity Smooth adjustable start stop ramp up ramp down Multiple operational modes Selectable adjustable autoclosing Pedestrian partial opening Positive close mode Independent safety inputs for opening and closing beams Automatic beam test for both open and closing beams Advanced beam alarm functions Advanced lightning surge protection Timed courtesy light output Multiple pre flashing modes Independently adjustable m
14. and when the connection is broken it will close after the pedestrian Autoclose time has expired The time taken for the gate to open to pedestrian is dependent on the pedestrian pre open delay and the time required for the gate to close from the pedestrian position is dependent on the pedestrian pre close delay Pedestrian open position Sets the maximum opening of the pedestrian gate in metres in one centimetre steps Pedestrian Autoclose time Sets the Autoclose time in seconds after a pedestrian opening This time can be set from zero seconds to four minutes in one second steps Pedestrian pre open delay Sets the time delay between the pedestrian input being activated and the gate actually opening This enhances safety in cases where the pedestrian has to reach through the gate in order to activate the pedestrian input A warning light would typically be active during this delay This delay can be set from zero seconds to four minutes in one second steps Pedestrian pre close delay Sets the time delay between the pedestrian Autoclose timer expiring and the gate actually closing A warning light would typically be active during this delay This delay can be set from zero seconds to four minutes in one second steps E The warning light is any light wired to the courtesy pillar light contacts as described in Menu 8 which follows page 45 XX Menu 8 Courtesy pillar light This feature is associated with the light co
15. as safety edges and safety beams for additional protection against entrapment or other mechanical risks Check that no pipes or electrical cables are in the way of the intended installation Check that enough space is available for the gate operator with the gate in the required open position Check for loose sandy soil if installing foundations as the soil condition may require a larger foundation Never fit the operator on the outside of the gate where the public has access to it Install the gate operator only if It will not pose a hazard to the public There is sufficient clearance to a roadway and or public thoroughfares The installation will meet all municipal and or local authority requirements once completed The gate mass length and application is within the operator specifications The gate is in good working order meaning That it moves freely Does not move on its own if left in any position It can be installed to have sufficient clearance between moving parts when opening and closing to reduce the risk of personal injury and entrapment Pushbuttons or keyswitches when required can be positioned so that the gate is in line of sight of the operator Endstops Fit endstops capable of stopping the gate at rated speed Refer to specifications at the beginning of this manual for the operating speed Make H gt h to ensure gate will not jump over endstop FI GURE 3 FITTING ENDSTOPS WARNI
16. battery leads It must be between 13 6V and 13 8V if not replace the charger Battery might be old and might have to be replaced If in doubt test as follows Check that the battery is charged by ensuring that the battery voltage is above 13 5V with the charger connected If the battery is in a good condition it would probably pass the test without being fully charged Disconnect the charger from the battery Remove the DC Motor leads from the DC Controller Apply the DC motor leads directly to the battery while measuring the battery voltage A First make sure that the moving gate will not pose any danger f the battery voltage drops to below 13 5V then the battery must be replaced Before replacing the battery measure the charging voltage on the battery leads with the battery disconnected Voltage must be between 13 6V and 13 8V If not replace the charger Procedure B False collision detection Status light flashes four times to indicate that number of collisions have exceeded the Collision Counter feature value LCD screen indicates Max Collisions With the operator in manual mode check the following and correct if necessary Badly running gate or something physically obstructing the gate Check along the entire travel of the gate Rack is not pressing down on to pinion Bad rack joints Wheels are not seized or running badly Top guide rollers are not restricting the gate No dirt on rail No physical da
17. following way When the gate is triggered to open and nothing moves through or interrupts the closing beam the gate will open fully and stay open for the period of time determined by the Autoclose timer However if the closing beam is interrupted at any stage while the gate is opening or open the gate will close immediately after the closing beam is cleared remain open indefinitely To close the gate the closing beam must be interrupted or the trigger button must be pressed E If the Autoclose feature has not been enabled then the gate will Stop on open If PIRAC is enabled and a vehicle breaks the closing safety beam the gate will by default continue to open If the gate is required to stop at this point the stop on open function must be enabled The stopping distance setting then determines in centimetres how far the gate will run on after the beam has been broken The minimum setting is zero which will cause the gate to stop immediately after the closing beam has been broken The maximum setting is determined by the length of the gate PIRAC override The PI RAC feature can be temporarily disabled in the following manner With the gate in the closed or partially closed position press and hold the trigger button The gate will begin to open and then stop Continue holding the trigger button until the gate begins to open again Release the trigger button The gate is now in PIRAC override To re enable the PI RAC
18. information that could be useful E aspects that should be considered during the installation during installation This icon indicates warning caution or attention Please take special note of critical aspects that MUST be adhered to in order to prevent injury page 8 5 Product identification ta 9 EA PR qe D5 Evo controller Courtesy light fuse 3A F B 1 x 12V 7 2Ah battery Gate mounted origin marker Origin marker bracket Origin sensor page 9 FIGURE 2 PRODUCT IDENTI FI CATI ON Side covers Foundation plate Motor fuse 30A ATO SM2A charger Manual release access door P6 Required tools and equipment Pull scale 50kg Spanner 17mm 10mm e Screwdriver 3 5mm flat e Allen key 6mm 4mm Crimping tool and pin lugs e Side cutters e Hacksaw e Spirit level e Measuring tape If casting foundation plate into concrete Pick e Spade If bolting foundation plate onto existing plinth e Drilling equipment e Masonry bits to suit rawlbolts being used If welding foundation plate and or rack to gate Welding equipment e G Clamp 6 inch x 2 If left hand side of gearbox is mounted close to a post e Socket wrench e Extension piece 17mm socket If fastening rack to gate e Drilling equipment TEK screw socket page 10 7 Preparation of site General considerations for the installation Always recommend the fitment of additional safety equipment such
19. into position File away the front lip of the rack if you need to move the origin marker closer to the operator as the gate slides past With nylon angle rack it is necessary to use the bracket provided It is preferable to use self tapping fasteners to secure the bracket into the side of the nylon angle rack as shown Make a small tack weld to secure the back of the bracket onto the angle iron section of the rack Bolt the origin marker onto the bracket using the fasteners provided page 26 Steel rack Bolt using fasteners provided racket Weld mountin bracket provided to steel rac FI GURE 32 RAZ rack FI GURE 33 Nylon angle rack Bolt using fasteners provided Origin marke racket Screw into side of the nylon rack FIGURE 34 13 Note the orientation of the origin marker FIGURE 35 14 Manually slide the gate open until the origin marker is in line with the origin Origin sensor Mare 15 Ensure distance between face of marker and front face of sensor is between 13 and 20mm 16 Adjust distance by sliding the origin marker along the slotted mounting holes until the specified distance is achieved For best results keep gap between marker and sensor as small as Origin sensor possible FI GURE 36 Apply warning decal WARNING WARNING WARNING WARNING WARNING KEEP CLEAR GATE MAY MOVE AT ANY TIME Apply the supplied warning decals to the gate as indica
20. it reaches the fully closed position If the value exceeds the value set in the multiple collision counter the controller shuts down until the next valid trigger is received As indication the status LED will flash four times every two seconds The multiple collision fault indication will continue to flash indefinitely or until a valid trigger has been received Alarm output After the preset collision count has been reached an alarm is activated The system can be configured to operate one of the following outputs provided on the controller Onboard buzzer emits a continuous tone Pillar Courtesy light contact potential free normally open contact fuse protected 5A Aux IO this is an open collector drive max current draw 3A not fuse protected Safety beam common this is an open collector drive max current draw 3A not fuse protected Status LED output operate up to three LEDs in parallel or interface with multi LED driver card CP78 LCK input as ESTOP Allows the Lck Holiday Lockout input to be configured as an emergency stop input When activating the emergency stop it will prevent the gate from moving and if it is moving it will immediately stop Menu 3 Autoclose Autoclose status When turned on the Autoclose feature has the function of automatically closing the gate after a preset Autoclose time The Autoclose feature is automatically turned on when the controller is set for Condominium Mode
21. receiver and control card that the receiver has power that the receiver is not faulty that the remotes are learned correctly to receiver Procedure A Low battery voltage condition Status light flashes three times LCD indicates Battery Low If the battery voltage is less than 13 5V the motor would not operate at all For any other voltage the battery could still be the cause of the problem Is the battery being properly charged Check the mains present icon on the main diagnostic screen or switch to the battery charger diagnostic screen and check the charger voltage right hand value This should indicate xV Check that the mains power is turned on measure 220V AC on the mains connector Check that the red LED on the side of the charger is lit Check the charger s supply fuse D5 Evo charger 34 Check that the white battery charger connector is making proper contact Check the condition of the battery leads terminals and connectors Look for and correct all loose connections and signs of corrosion The battery might be discharged Measure the battery voltage with the charger connected if the voltage is below 13 5V then the battery is discharged The number of opening cycles per hour may be excessive thus discharging the battery Refer to the Trip Counter diagnostic screen for assistance Charge the battery if required page 61 Charger might be faulty Disconnect the battery and measure the voltage on the
22. select the following Modes of Operation Standard Condominium Reversing PLC and Deadman Control Mode DMC All modes are triggered by closing a normally open contact between the Trg input terminal and the Com terminal Standard mode When stationary a trigger impulse on Trg will cause the gate to either open or close On a moving gate a trigger impulse on Trg will stop the gate The next impluse on Trg will cause the gate to reverse its direction of travel i e the action is start stop reverse Condominium mode A trigger impulse on Trg will open the gate under all conditions If it were closing it will stop and reverse to open In this Mode of Operation the only way to close the gate is with the Autoclose feature which is automatically activated when Condominium mode is selected Reversing mode A trigger impulse on Trg will reverse the direction of a moving gate If it were closing it will stop and immediately begin opening If it were opening it will stop and immediately begin closing PLC Mode A trigger impulse on FRX NO will cause the gate to open A trigger impulse on the Trg NO will cause the gate to close A trigger impulse on the Lck Stp NC will cause the gate to stop page 41 Deadman Control Mode DMC A permanent trigger on FRX NO will cause the gate to open Removing the trigger will cause the gate to stop A permanent trigger on Trg NO will cause the gate to close Removing the trigger will cau
23. 2 3 Delete all time periods and exlusions 10 3 Diagnostic screen 10 2 4 Reset all status 10 4 Test button disabled status 10 5 Backup eeprom 10 6 Restore eeprom Remote controls Press button of valid transmitter if menu locked 11 1 Add remotes 11 2 Delete remotes 11 2 1 Delete remote by ID 11 2 2 Delete remote button 11 2 3 Delete remote by button 11 2 4 Delete not present 11 2 5 Delete all remotes 11 3 Edit remote button 11 4 Autolearn 11 5 Lock Tx menu 11 6 Onboard receiver enable disable page 39 21 Controller features Menu 2 Safety collision force Collision force If the gate is obstructed the internal collision circuitry will activate The response of the system to a collision will vary depending on the profile operating standard e g ZA selected Responses can vary from the gate stopping to the gate reversing The collision force can be set from minimum to maximum in five discrete steps A sixth step will disable collision sensing entirely allowing maximum force to be achieved Under this condition the motor will continue running until it stalls at which point a collision will be detected This level should only be used if additional safety measures are taken e g infrared beams sensitive edge etc Collision force can be set independently per direction of travel Collision count A counter monitors the number of collisions that the gate experiences before
24. 34 page 35 page 35 page 36 page 37 page 40 page 51 page 53 page 56 page 56 page 56 page 57 page 58 page 59 page 63 page 63 page 63 page 64 L a N ERACK Mechanical setu Di 4 P These abbreviated instructions are for the experienced installer who needs a checklist to get a standard installation up and running in the minimum of time Detailed installation features and functions are referred to later in this manual E Heed necessary site considerations page 11 ie Check cabling reguirements page 14 Gather reguired tools and eguipment page 10 Jiii ep Secure foundation plate age 19 mi i iis sten Add oil t b 15 oil to gearbox age mi PSP Mount gearbox page 20 ME vount rack 21 ount rac age 1 j iii stop M t origi k 25 ount origin marker age g pag sip Apply warning decals page 27 z ar Ubi page 1 Electrical setup 10 st C t all wiri onnect all WIrin Commissioning and handover ste p Set gate end of travel limits mi ste 15 Set additional features via the me menus if required ste Carry out professional handover to client mE page 2 IMPORTANT Safety Instructions ATTENTI ON To ensure the safety of people it is important that you read all the following instructions Incorrect installation or incorrect use of the product could J cause serious harm to people e The installer being either professio
25. NG Endstops are mandatory and must be fitted to prevent death or accidental injury should the gate overrun its limits Guide rollers and anti lift brackets e Guide rollers must ensure that the gate is held vertically For improved safety fit additional support post to prevent gate from falling over if guide rollers fail To prevent unauthorised access fit anti lift brackets as shown The gap between the anti lift bracket and the gate must be less than 5mm Ensure that the gate cannot be lifted off the motor pinion with the anti lift bracket fitted GAP 5mm GAP lt 5mm Guide rollers GAP lt 5mm GAP lt 5mm Additional L a Y support post FI GURE 4 FITTING GUI DE ROLLERS page 12 Starting and running forces Test the starting force of the gate as per the diagram Use a pull scale to determine the maximum amount of pull force required to get the gate moving Determine the running force of the gate by continuing to pull on the scale with just sufficient force to keep it running and read off the maximum value in kgf shown on the scale Where possible determine the gate mass The Centurion Systems Pty Ltd warranty will be void if the pull force and or gate mass exceed the operator specification as below Starting force 30kgf e Running rated force 20kgf Maximum gate mass 500kg Pull scale FI GURE 5 STARTI NG AND RUNNI NG FORCES page 13 8 Cabling req
26. ams SC Safety common LED Status LED TX Transmitter P PLC mode XIO A Auxiliary input output page 52 23 Description of terminal functions UMS 12V 12V Motor Motor Aux 10 Com Status Aux FRX Com Positive battery connection Battery terminal normally indicated as or red right hand battery Negative battery connection Battery terminal normally indicated as or black left hand battery Motor output connects to the thick blue motor wire Motor output connects to the thick black motor wire The Aux IO terminal provides an open collector output which can be used for alarm or auto function purposes If the collision alarm output or the I RB alarm output has been configured to Aux IO then the negative of the alarm device must be connected to this terminal The positive of the alarm device must be connected to the Aux 12V Out terminal Similarly if Aux I O is autoactivated via a ChronoGuard auto function Time period the device being switched typically a 12V relay must be powered from the Aux 12V Out terminal and have its negative switched by Aux IO If the Aux IO has not been selected as either an alarm indicator output or autoactivated output the Aux IO terminal will behave as a Com termination point All trigger signals etc have their return path to one of the Com terminals The common termination point All trigger signals etc have their return path to one of the Com terminals
27. ant A FIGURE 51 IR beam broken time The time that the beams must be interrupted before the alarm is activated Break in alarm Activates an alarm if the closing beam on the outside of the property is interrupted The alarm remains activated while the beam is broken and for a period of 30 seconds thereafter This time is fixed Only active when gate is fully closed If this alarm is used it is recommended that TWO parallel closing beams are Intruder breaks beam _ used to reduce the chance while loitering at gate 77 of false triggering FIGURE 52 page 44 Alarm output The system can be configured to operate one of the following outputs provided on the controller Onboard buzzer emits a continuous tone Pillar Courtesy light contact potential free normally open contact fuse protected 5A Aux IO this is an open collector drive max current draw 3A not fuse protected Safety beam common this is an open collector drive max current draw 3A not fuse protected Status LED output operate up to three LEDs in parallel or interface with multi LED driver card CP78 JA Menu 7 Pedestrian opening This feature is associated with the Ped input on the controller When activating this input the system will open the gate to the pedestrian open position and then automatically close after the pedestrian Autoclose time lapses If the Ped connection to Com is maintained then the gate will remain open
28. any specific day The minimum duration of a time period is one minute Once off Time period have the highest precedence followed by annual and then weekly When appropriate a Tp icon will appear on the display to indicate that a Time period is active Auto activations Auto function The following controller inputs can be set to activate automatically during a Time period Free exit FRX Pedestrian opening Ped Holiday Lockout Lck Closing beam IRBC Courtesy light control Aux During the relevant time period the selected input will be activated Where appropriate the diagnostic LED of the relevant input will illuminate The following controller output can be set to activate automatically during a Time period e Auxiliary output Aux 10 Time barring Time barring of inputs is divided into physical inputs and RF inputs inputs mapped to a CENTSYS code hopping transmitter button The following physical inputs can be time barred prevented from operating during a Time period Trigger Trg Pedestrian opening Ped Free exit FRX Holiday Lock Lck Courtesy light control Aux The following physical outputs can be time barred prevented from operating during a Time period Courtesy pillar light relay Light e Auxiliary output Aux IO The following RF inputs can be time barred prevented from operating during a Time period Trigger Trg Pedestrian opening Ped
29. ater entering the gearbox and the warrantee will be void Re engage gearbox drive l Rotate thumbwheel anti clockwise until thumbwheel feels loose in the hand Make sure that the manual override access door can be closed 2 Slide gate until gearbox drive engages Do not remove the Thumbwheel thumbwheel Removal of the LP iNcDO NOT REMOVE thumbwheel may result in e i Turn anti clockwise water entering the gearbox and until it feels loose the warranty will be void FI GURE 57 page 63 27 Installation handover Once the installation has been successfully completed and tested it is important for the installer to explain the operation and safety requirements of the system NEVER ASSUME THE USER KNOWS HOW TO SAFELY OPERATE AN AUTOMATED GATE Even if the user has used one before it does not mean he knows how to SAFELY operate it Make sure that the user fully understands the following safety requirements before finally handing over the site The following needs to be understood by the user How to operate the manual release mechanism Show them how by demonstration How the obstruction detection and all other safety features work Show them how by demonstration All the features and benefits of the operator i e safety beams ChronoGuard etc All the safety considerations associated with operating an automated gate The user should be able to pass this knowledge on to all other users of
30. eed varies with load Manual override Maximum numbers of operations per day FI GURE 1 OVERALL DI MENSI ONS 220 240V AC 1096 50Hz 12V DC Battery driven standard capacity 1 x 7Ah 2A 9 14 2V charging voltage 13 76V 170mA 10A 25 9KUf 17kgf 500kg 100m 18 22 m min Lockable door with key release 150 page 7 Duty cycle mains present 50 Operations in standby with 7Ah battery half day 44 full day 35 Operations in standby with 35Ah battery half day T50 full day 150 Collision sensing electronic Operating temperature range 15 C to 50 C Onboard receiver type CENTSYS code hopping multichannel Receiver code storage capacity 500 transmitter buttons Receiver frequency 433MHz Mass of unit packed standard kit excl rack and battery 10kg Packing dimensions standard kit excl rack and battery 231mm deep x 303mm wide x 432mm high Based on a push force of less than 50 of rated Limited by maximum daily usage 3 Based on 4m gate no accessories fitted such as infrared beams Fuse protection The following protection fuses are provided on the system Item Type Rating Main controller Motor circuit Automotive fuse ATO 25 x 7mm 30A Light circuit 5 x 20mm 3A fast blow Auxiliary supply Resettable fuse 3A Charger Mains input 5 x 20mm 3A fast blow Not user serviceable 4 Icons used in this manual This icon indicates tips and other This icon denotes variations and other
31. een determined to suit the requirements of the specific region where the installation is being carried out It is only necessary to change a feature where the default does not suit the installation When selecting any feature in the menu details of the current setting stored in the controller are displayed Refer to Section 22 for the Schedule of factory defaults for each feature page 36 20 Menu navigation map Me I api da gt E hy d 4 B 22 25 2 4 25 Sl 3 2 3 3 3 4 Setting limits 1 1 Setup wizard Safety Collision orde ea 2 1 1 Opening collision force 2 12 Collision count Alarm output LCK input as ESTOP External gate indication status 25 1 2502 2 519 PAN 255 2 5 0 25 2 5 8 2 5 9 Autoclose Autoclose status Autoclose timer Autoclose override Autoclose advanced options 3 4 1 Deli 3 43 Modes of operation Operating Mode an e nae a 4 1 1 a IL dal zio Z0 page 37 Closing collision force Indicator output Closed indication Part close indication Closing indication Part open indication Opening indication Open indication Pedestrian indication Unknown indication Autoclose fully open Autoclose partly open Autoclose partly closed Standard mode Condominium mode Reversing mode PLC Deadman Control mode 5 Run profile Slee OSGI CG OSC M 5 1 1 Positive close mode status 5 1 2 Positive close mode force
32. el is reached when the oil level is in the flat section of the dipstick le Emptying the 80ml bottle of oil provided will give sufficient oil Put 80ml oil in here Oil specifications Centurion Systems Pty Ltd product code OIL80MLOXO H Oil filling procedure Lift the cover of the operator Remove the battery so that you can gain access to the coloured filler plug Remove the coloured oil filler plug by levering it out with a screwdriver Empty the contents of the oil bottle into the gearbox 80ml Refit the coloured oil filler cap S Upright detail removed for clarit FIGURE 7 OPERATOR LUBRICATION page 15 10 Operator installation dr Locate operator position To ensure operator does not protrude into driveway install base plate at least flush with the driveway entrance Determine a suitable position and vertical height for the operator by considering Figures 8 9 and 10 t is typical to mount the rack above the pinion as shown in Figures 8A 9A and 10A for each type of rack considered However in each case Figures 8B 9B and 10B show the rack mounted underneath If there is space to mount the rack underneath without fouling the ground as the gate moves the following are the pros and cons Pros The rack is more hidden from view It provides a very effective anti lift bracket t ensures that as the gate beds in the rack does not drop onto the pinion loading the op
33. erator unnecessarily Cons Rack teeth face up vertically potentially collecting dirt Custom bracket With careful selection of the rack configuration and operator vertical height mounting of the rack could in some cases be greatly simplified If a theft resistant cage is required be sure to leave enough clearance from pillars etc If using nylon angle rack please ensure that the weight and pull force of the gate do not exceed the strength limit of the rack Recommended to allow for adjustment Recommended to allow for adjustment Foundation Foundation plate 3 plate Flat bar welded t Raised foundation foundation plate sha rail Includes 3mm clearance required between rack and pinion FIGURE 8A Steel rack above pinion FIGURE 8B Steel rack below pinion page 16 RAZ rack allow for adjustment allow for adjustment Recommended to o di v Q o ES O E E O Q Q ol Foundation Foundation plate plate Flat bar welded to Raised foundation foundation plate and rail Indudes 3mm dearance required between rack and pinion FI GURE 9A RAZrack above pinion FI GURE 9B RAZ rack below pinion Nylon angle rack Recommended to allow for adjustment Recommended to allow for adjustment
34. esent e g intercom button pressed while a non illuminated green LED indicates that the signal is absent e g IRB broken Safety close green On when the closing beam is not activated Safety open green On when the opening beam is not activated Lck Stp green On when the Lck Stp input is not activated Trg red On when the trigger signal is present Ped red On when the pedestrian signal is present FRX red On when a free exit signal is present Aux red FI GURE 53 On when an auxiliary signal is present Status red This LED indicated the status of the gate as per the table below Gate status LED Off Gate is closed On Gate is partially or fully open Continuous slow flash Gate is opening Continuous fast flash Gate is closing One flash every two seconds Pillar light override is activated Two flashes every two seconds No mains present Three flashes every two seconds Battery voltage is low page 56 LCD display The LCD display shows useful information regarding the status of the system FIGURE 54 1 Battery icon Indicates the state of charge of the battery Four solid bars full capacity Two solid bars 50 capacity No solid bars with the icon flashing battery empty 2 Mains icon Displays the presence or absence of mains voltage Plug solid mains present and battery charging Plug hollow and flashing No mains present and battery not charging 3 Autoclose information Disp
35. feature press the trigger button briefly The time taken for the gate to come to a stop is equal to the Autoclose override time or a minimum of two seconds if the Autoclose override time is off page 43 The time taken for the gate to open again after it has come to a stop is approximately three seconds Example Autoclose override time set to five seconds Total time to temporarily disable the PIRAC feature is approximately eight seconds 5s 3s 8 seconds Autoclose override time set to off Total time to temporarily disable the PIRAC feature is approximately three seconds IR beam test Automatically tests the safety beams before each gate cycle e g as required by CE In order for this feature to work the power supply negative of beam transmitter must be wired to the safe common terminal of the controller IRBO IRBC Configures the opening beam to act as a closing beam while the gates are closing IR beam alarms This feature allows the following alarms e Ambush alarm Activates an alarm if either the opening or closing beams have been continuously interrupted for a predefined time The alarm will remain activated while the beams are interrupted For example if a would be intruder covers the beams so that when the gate is opened the gate gi will stay open the system will po detect this beam override taking time place and set off an alarm Active ee o at all points of gate travel nlocks be
36. g If the Safety Open and reverse functions are not required a Pod link must be fitted between Safety Open and Safe Common for the controller to operate normally refer to note on page 55 Closing beam safety input A normally closed potential free input As long as a connection between this input and Common is maintained the controller will behave normally When this connection is broken it will prevent the gate from closing if it is stationary and will stop and open the gate if it is closing This input has no effect if the gate is opening Cd If the Safety Close function is not required a link must be fitted y between Safety Close and Safe Common for the controller to operate normally refer to note on page 55 Auxiliary power connection Provides 12V DC supply for auxiliary equipment such as a radio receiver photo cells etc It is electronically limited to 300A page 54 Light light Pillar light connection These two terminals provide a normally open potential free contact which is generally used to switch on a pillar light courtesy light This contact is fuse protected refer to Section 3 for fuse specifications page 55 24 Diagnostics J Diagnostic LEDs The D5 Evo controller has a series of diagnostic LEDs which indicate the state of the inputs Normally open inputs are indicated by a red LED and normally closed inputs by a green LED An illuminated red LED indicates that the signal is pr
37. he edit remote button select Ped and button one of the same remote will now only open the gate to pedestrian Autolearn Allows a selectable time period to be set during which any specific button when pressed will be learned to a specific function The function itself will also be activated when the button is pressed After the time period has expired autolearn is disabled and no further buttons will be learned The time period can be set from one hour to seven days in one hour increments Tx menu locked Allows the remote controls menu to be locked preventing the unauthorized addition of new transmitters to the system Once enabled the remote controls menu can only be accessed by pressing a valid transmitter button Onboard receiver The onboard CENTSYS code hopping receiver can be disabled in the unlikely event that it causes interference with an existing external receiver page 50 22 Factory defaults schedule South African standard profile ZA Parameter Description Unit Minimum Menu 1 not applicable Menu 2 Opening collision force Level 1 Closing collision force Level I Collision count Collisions 1 Alarm output B CL SC XIO LED LCK as ESTOP Yes or No Menu 3 Autoclose status On Off Autoclose timer mm ss 00m 00s Autoclose override time mm ss 00m 00s Autoclose from fully open On Off Autoclose from partly open On Off Autoclose from partly On Off closed Menu 4 Modes of Operation SFC R PD Menu
38. ight connections F Ww a i ME Y m leads al Charger connection S Red Black charger wir s EN il gal bz am arth Auxiliary to light connection casing on charger FI GURE 45 FI GURE 46 SCHEMATI C OF BATTERY CONNECTI ON SCHEMATI C OF LI GHT CONNECTI ON page 33 17 Earthing for effective lightning protection I EEA A PR Spade connection harness Optional 40kA surge arrestor Earth spike 51m copper rod hammered into the ground FI GURE 47 page 34 18 Commissioning the system Setting the gate limits 1 Disengage the manual release lever TT ensuring that the origin marker is correctly fitted TI Move the gate to the middle of travel and KAN al LAN KONI INN re engage the manual release lever FI GURE 48 2 a If powering up the system ex factory it will request for the operating Profile operating standard to be set ZA Standard profile for South Africa CE Standard profile for the European Union UL325 Standard profile for the USA b Select the Profile that will suit the specific region from the list With this set the system will automatically proceed to the limit setup menu Follow the onscreen instructions to complete the setup procedure A Setup Wizard Exit eap Accept C If powering up at any stage after this push and hold the oblong enter b
39. ion Any other use not expressly indicated here could compromise the service life operation of the product and or be a source of danger Everything not expressly specified in these instructions is not permitted WARNING WARNING WARNING WARNING WARNING KEEP CLEAR GATE MAY MOVE AT ANY TIME MOVING GATE CAN CAUSE SERIOUS INJURY OR DEATH KEEP CLEAR GATE MAY MOVE AT ANY TIME DO NOT ALLOW CHILDREN TO PLAY IN AREA OR OPERATE GATE page 4 PT Declaration of conformity J Manufacturer Centurion Systems Pty Ltd Unit 13 Production Park Intersection Newmarket Road amp Epsom Avenue North Riding Gauteng South Africa Declares that the product Product name D5 Evo Conforms with the following specifications Safety SANS 60335 1 2007 IEC 60335 1 2006 Emissions CISPR 22 CLASS B Radiated emissions 150KHz TO 6GHz CISPR 22 CLASS B Conducted emissions 150KHz TO 6GHz Immunity IEC 61000 4 2 Electrostatic discharge IEC 61000 4 3 Radiated immunity 80MHz TO 1000MHz EC 61000 4 4 Electrical fast transients burst IEC 61000 4 5 Surges IEC 61000 4 6 Conducted immunity 150KHz TO 80MHz Standard to which conformity is declared IEC 60335 1 2006 Safety IEC 61000 6 3 2006 Emissions IEC 61000 6 1 2005 Immunity Signed at North Riding South Africa on June 21 2010 A lan Rozowsky Research amp Development Director page 5 2 General description The D5 Evo is a domestic
40. lays the state of the Autoclose function Displays off if Autoclose is not selected OVR if Autoclose is overridden and the remaining Autoclose time if Autoclose is active POVR indicates that the PIRAC option is overriden 4 Pillar light information Displays the remaining light time if courtesy light mode is selected Pre flashing mode is displayed if pre flash is selected LIT will be indicated if the pillar light has been turned on permanently 5 Onboard receiver information Displays the current input being activated by the onboard receiver 6 Status information Displays useful information regarding the status of the gate page 57 Buzzer feedback A warning buzzer will sound where applicable as per the table below P 20 Gate User can Continuous tone ES l beep periodically Holiday Lockout for 30 ceconds User Yes 2 beeps periodically Power system Mains failure for 30 seconds fault Yes for 30 seconds Fuse blown 14 5 beeps periodically Hardware Yes for 30 seconds Bridge 5 beeps periodically damaged for 30 seconds Hardware No Periodic until condition is cleared by user 500 500ms Multiple collision 3 No magnet Periodic while gate runs last Yes Mad 500 500ms Gate will close fully and then shutdown for two minutes page 58 725 Fault finders guide Problem Possible faults Fuse is blown Check 30A ATO fuse and replace if necessary Lck
41. mage to the rail Wheel catching side of pinion With the operator in normal mode check the following and correct if necessary Gate is not hitting the endstop Do a general inspection of system check the following and correct if necessary No ants dirt oil or water in and around the DOSS sensor DC motor wires for loose connections DOSS sensor wire harness is securely plugged into controller DOSS sensor is securely clipped into the housing If the problem is not solved replace the DOSS sensor and main controller E Red black orange wire Origin switch and Red black purple wire DOSS sensor page 62 26 Manual operation Disengage gearbox drive l Use key to open access door to manual override Do not remove the thumbwheel Removal of the thumbwheel may result in water entering the gearbox and the warrantee will be void FI GURE 55 2 Rotate thumbwheel clockwise until gearbox releases and gate can be moved manually 3 If the gearbox must be left in manual mode for an extended period of time for whatever reason it is recommended that the access door is locked This secures the cover and prevents access to the inside of the unit which contains high voltages It also prevents theft of any Os Thumbwheel components and provides full protection 1 b Turn clockwise from the elements to release Do not remove the thumbwheel Removal of FIGURE 56 the thumbwheel may result in w
42. n the correct position and use the plate as a template for marking the rawl bolt holes Use two M12 Sx plated nuts as spacers 4 Assemble foundation plate without anchor brackets before bolting down onto plinth Ensure that the M10 gearbox mounting bolts are properly tightened FI GURE 13 Route cables and secure foundation plate l Route cables as determined in Section 8 Cabling requirements 2 Make sure that all cables and conduits protrude at least 400mm above the baseplate once installed as shown in Figure 14 Make sure that the M10 bolts which secure the gearbox are in place 3 Securely concrete or bolt the foundation plate in position FI GURE 14 page 19 Mount the gearbox 1 Fit the M10 nuts and washers to the mounting bolts as shown in Figure 15 2 Adjust the nuts to be 7mm clear from the base to allow for later adjustment Remember to fit the washers onto each nut before installing the gearbox 3 Remove the knock outs for the cables from the gearbox 4 Feed the cables through these holes while fitting the gearbox to the baseplate 5 Note how the cables route up onto the control card 6 Check that the operator is level Secure the gearbox in place fitting a washer spring washer and nut onto each gearbox mounting 8 Seal the conduit and knock out holes in the operator with silicone sealer to prevent ants from entering the operator
43. nal or DI Y is the last person on the site who can ensure that the operator is safely installed and that the whole system can be operated safely Warnings for the installer CAREFULLY READ AND FOLLOW ALL INSTRUCTIONS before beginning to install the product All installation repair and service work to this product must be carried out by a suitably qualified person Do not activate your gate opener unless you can see it and can determine that its area of travel is clear of people pets or other obstructions NO ONE MAY CROSS THE PATH OF A MOVING GATE Always keep people and objects away from the gate and its area of travel NEVER LET CHILDREN OPERATE OR PLAY WITH THE GATE CONTROLS Secure all easily accessed gate opener controls in order to prevent unauthorized use of the gate Do not in any way modify the components of the automated system Do not install the equipment in an explosive atmosphere the presence of flammable gasses or fumes is a serious danger to safety Before attempting any work on the system cut electrical power to the operator and disconnect the batteries The mains power supply of the automated system must be fitted with an all pole switch with contact opening distance of 3mm or greater Use of a 5A thermal breaker with all pole circuit break is recommended Make sure that an earth leakage circuit breaker with a threshold of 30mA is fitted upstream of the system Never short circuit the battery and do not
44. nnections on the controller Refer to Section 16 of the manual for details on how to connect a pillar or security light to the controller The pillar light circuit has multiple functions t operates as a courtesy light and switches on for a selectable time period every time the gate is activated The courtesy light can also be turned on for the same time period by momentarily connecting the Aux terminal to the Com terminal via a pushbutton The courtesy light can also be turned on permanently by connecting the Aux terminal to the Com terminal via a pushbutton for three seconds A short pulse thereafter will switch the lights off The status LED will flash once every two seconds to indicate that the courtesy light is on permanently The abovementioned facility can also be achieved via a remote learned to the system and mapped to the courtesy light function from within the remotes menu E The gate will not open when using the Auxtrigger input When the Ped input is triggered the courtesy light flashes for an adjustable 1 to 255 seconds pre flash time before the pedestrian gate opens The courtesy light can also be controlled via the Auto activation function or the light time bar function as described in the ChronoGuard Time periods menu Menu 9 Courtesy light time The time that the courtesy light will remain activated can be set from four seconds to ten hours in one second increments Light profile The cour
45. of Operation d Autoclose time The Autoclose time can be set anywhere from 1 to 255 seconds page 40 t mr Autoclose override It is possible for the user to temporarily turn off Autoclose when the Mode of Operation is Standard or Reversing To activate Autoclose Override the Trg input must be activated and maintained for a period longer than the time set for the Autoclose Override time The gate response will be to start opening on the Trg trigger and then to stop as soon as the Autoclose Override feature is activated On clearing of the Trg input the gate will continue opening until fully open The Autoclose feature is now off and the gate will remain open indefinitely The next signal received on Trg will clear the Autoclose Override feature close the gate and set the Autoclose feature back to normal Autoclose advanced options The conditions under which the gate will automatically close can be set within the Advanced Autoclose options menu Autoclose on open automatically close the gate if it has reached the fully open position Autoclose on partly open automatically close the gate if it is stopped while opening but before reaching the fully opened position Autoclose on partly closed automatically close the gate if it is stopped while closing but before reaching the fully closed position amp More than one advanced option can be selected Menu 4 Modes of Operation It is possible to
46. ormally open potential free input Momentarily connecting this input to Com will cause the gate to open to the pedestrian open position For more information refer to the pedestrian feature in Section 21 Trigger input A normally open potential free input Momentarily connecting this input to Com will cause the gate to open close or stop depending on the operating mode selected For more information see the Autoclose feature and Modes of Operation Holiday Lockout or gate stop input A normally closed potential free input For as long as a connection between this input and Com is maintained the controller will behave normally but when this connection to Com is broken all inputs are inhibited e f this input is enabled while the gate is moving or in the open position it will only activate and inhibit operation of all the inputs when the gate is back in the closed position This input can be configured as an emergency stop input Refer to Section 21 Menu 2 for details If the Lck function is not required a link must be fitted between Lck and Com refer to note on page 55 Opening beam safety input A normally closed potential free input As long as a connection between this input and Common is maintained the controller will behave normally When this connection is broken it will prevent the gate from opening if it is stationary and will stop and close the gate if it is opening This input has no effect if the gate is closin
47. otor speed in both opening and closing directions Onboard CENTSYS code hopping radio receiver with full channel mapping capability limited to 500 buttons Onboard ChronoGuard timer patent pending for autoactivation of various physical input and outputs and time barring of the same inputs and output including remote controls Lightning Protection The electronic controller utilizes the same proven surge protection philosophy that is used in all CENTSYS products While this does not guarantee that the unit will not be damaged in the event of a lightning strike or power surge it greatly reduces the likelihood of such damage occurring The earth return for the surge protection is provided via the mains power supply earth and or earth spike located next to the operator o Theft Protection While care has been taken in the design of the D5 Evo to prevent unauthorized removal theft of the unit an optional steel theft resistant cage is also available for added peace of mind In order to ensure that the surge protection is effective it is essential that the unit is properly earthed page 6 F3 Specifications Physical dimensions Technical specifications Input voltage Motor voltage Motor power supply Battery charger Current consumption mains Current consumption motor at rated load Operator push force starting Operator push force rated Gate mass maximum Gate length maximum Gate sp
48. r is in possession of the User Guide and that you have completed the installation details in the back of the User Guide page 64 CENTSYS 0 07 B 0029 D5 Evo Installation Manual 10 ul2012 www centsys com au
49. re installed 3K Type of cable must adhere to municipal bylaws but typically SWA steel wire armoured cable is recommended The su gek provides excellent screening which gives better protection against lightning earth one end of the screening Allows for all features such as pedestrian opening status LED etc to be operated from the intercom handset nu IDA Number of cores and type of cable could vary depending on brand of access control system eing use For optimum range an external receiver can be mounted on the wall 3 Consult manufacturer of loop detector for specific details page 14 79 Lubrication Do not attempt to run the operator without first filling the gearbox with The internal gearset of the D5 Evo is lubricated by means of an oil bath In order to prevent possible leakage during shipping the unit is shipped with no oil inside the gearbox A bottle containing 80ml of a special synthetic oil is included with the product and this must be introduced before operating the product Product code OIL80MLOXO H It is more convenient to introduce oil before bolting the unit down as shown in Figure 7 The D5 Evo does not require routine oil changes However in the event of the unit losing oil due to stripping down or mechanical damage the correct replacement oil is Castrol SAF X0 75W 90 synthetic final drive lubricant If the gearbox is bolted down in the horizontal position during filling the correct lev
50. se the gate to stop A permanent trigger on Lck Stp NC will stop a moving gate and prevent a stationary gate from moving Menu 5 Run profile Positive Close Mode PCM Setting Positive Close Mode to on will allow the gate to drive up hard to the closed endstop without causing the collision circuitry to operate This feature operates only during the last few millimeters of gate travel in closing mode PCM push force The amount of force applied by the motor when in PCM can be set as a percentage of full motor force Pre open delay Allows a delay between a valid trigger signal being received and the gate commencing movement in the opening direction A warning light can be set to activate during this delay Refer to pre flash modes of the pillar light feature for more details Pre close delay Allows a delay between a valid trigger signal being received and the gate commencing movement in the closing direction The delay will also occur if the gate is set to close automatically A warning light can be set to activate during this delay Refer to pre flash modes of the pillar light feature for more details Opening speed Sets the maximum opening speed in metres per minute This can be set from 10 to 22 metres per minute Selecting maximum will move gate at maximum possible speed Closing speed Sets the maximum closing speed in metres per minute This can be set from 10 to 22 metres per minute Selecting maximum will move the gate a
51. t maximum possible speed Ramp up distance Sets the ramp up distance in centimetres of travel of the gate when starting This can be set from 10 centimetres to 10 metres in 1 centimetre steps Ramp down distance Sets the ramp down distance in centimetres of travel of the gate when stopping This can be set from 10 centimetres to 10 metres in 1 centimetre steps TRG stop distance Sets the distance over which a moving gate will stop after a Trg input is received This can be set from 10 centimetres to 1 metre in 1 centimetre steps IRB stop distance Sets the distance over which a moving gate will stop after an infrared safety beam is broken This can be set from 10 centimetres to 1 metre in 1 centimetre steps page 42 Crawl distance Sets the final crawl distance in centimetres of travel of the gate when reaching an endpoint This can be set from 10 centimetres to 10 metres in 1 centimetre steps Torque limit Sets the maximum torque delivered by the motor The maximum setting is a value of 15 while the minimum is four This is useful in cases where limited push force is required I1 Menu 6 IR beams PIRAC The Passive l nfrared Autoclose feature allows the gate to close automatically as soon as a vehicle or pedestrian has passed through the closing beam This security feature ensures that the gate stays open for the minimum amount of time possible If the Autoclose feature has been enabled the system will react in the
52. t be affected Delete all remotes Delete all the remotes stored in the system no settings affected Delete all Time periods All autoactivation auto function and time bar functions are deleted or removed Reset all Clears and defaults the system completely Unit will be reset to the factory default settings in addition to clearing all remotes and time periods Diagnostic screen Allows a diagnostic screen to be displayed This can be useful when troubleshooting but requires some technical knowledge Round test button Allows the round test button on the controller to be disabled in cases where higher security is required Backup EEPROM Allows all controller settings remote controls and Time period functions to be backed up Requires a backup module obtainable from CENTSYS Restore EEPROM Allows all controller settings remote controls and Time period functions that have previously been backed up to be restored Requires a backup module obtainable from CENTSYS page 48 If the backup module is used to restore the settings of a different D5 Evo operator then the gate limits setup procedure must be performed again Menu 11 Remote controls N The controller is capable of learning up to 500 CENTSYS code hopping remote control buttons Each transmitter can have up to four buttons t is possible to artificially increase the number of buttons of a multi button transmitter by using a two button combination
53. ted on the reverse side of the decal MOVING GATE CAN CAUSE SERIOUS INJURY OR DEATH KEEP CLEAR GATE MAY MOVE AT ANY TIME DO NOT ALLOW CHILDREN TO PLAY IN AREA OR OPERATE GATE page 27 PT1 Electrical setup 1 Always check that the circuit breaker in the electrical panel is in the OFF position and that all high voltage circuits more than 42 4V are amp completely isolated from the mains supply before doing any work 2 Ensure that all low voltage systems less than 42 4V are suitably protected from damage by disconnecting all sources of power such as chargers and batteries before doing any work 3 All electrical work must be carried out according to the requirements of all applicable local electrical codes It is recommended that a licensed electrical contractor perform such work Connect all wiring 1 Connect all cables as required to the control card and battery charger according to the wiring diagrams as shown in Sections 12 to 16 that follow 2 Ensure that both the controller and the charger are effectively earthed for improved lightning protection Refer to Section 17 3 Check that the charger and battery are jo Sla Yin asa Ga E si Ed 5 Pa SP connected to the controller mel Ensure that the battery polarity is correct FI GURE 39 page 28 PT2 Wiring diagram for closing safety beam Closing safety beam rt rt Safe Common Aux 12V Out J9AI929M GUI Q FR
54. tesy light can be selected to operate according to one of the following Courtesy light as explained earlier Pre flashing mode If pre flashing Mode A B or C is selected the behaviour of the courtesy light will be as follows Mode A will turn on the courtesy light only while the gate is moving Mode B will flash the courtesy light during the pre opening and pre closing delays as well as while the gate is moving Mode C will turn on the courtesy light during the pre opening and pre closing delays as well as while the gate is moving In these pre flashing modes the timed courtesy light functionality is not available 2 Menu 9 ChronoGuard Time periods ChronoGuard patent pending is a powerful feature which has been added to the new generation CENTSYS controllers An integral Real Time Clock RTC is used to provide time based functionality including the automatic activation or time barring of specific controller inputs and the time barring of specified page 46 remote control buttons used together with the onboard CENTSYS code hopping receiver The RTC will keep time for a minimum of one hour without any power Time periods A Time period is defined by a start and end date and time Up to one hundred Time periods can be defined A Time period can be a once off event or can be set to repeat on a weekly or annual basis The weekly repeat can be chosen to occur on every day of the week weekdays only weekends only or
55. the automated system and must be made aware of this responsibility Do not activate the gate operator unless you can see it and can determine that its area of travel is clear of people pets di or other obstructions NO ONE MAY CROSS THE PATH OF A MOVING GATE Always keep people and objects away from the gate and its area of travel NEVER LET CHILDREN OPERATE OR PLAY WITH THE GATE CONTROLS and do not allow children or pets near the gate area Be careful with moving parts and avoid close proximity to areas where fingers or hands could be pinched Secure all easily accessed gate operator controls in order to prevent unauthorized use of the gate Keep the automated gate system properly maintained and ensure that all working areas are free of debris and other objects that could affect the gate operation and safety On a monthly basis check the obstruction detection system and safety devices for correct operation AII repair and service work to this product must be done by a suitably qualified person This product was designed and built strictly for the use indicated in this documentation Any other use not expressly indicated here could compromise the good condition operation of the product and or be a source of danger gamer ny d Sy d Centurion Systems Pty Ltd does not accept any liability caused by improper use of the product or for use other than that for which the automated system was designed Ensure that the custome
56. this way to fix all sections FIGURE 22 Refer to the sections that follow for instructions on how to join the different types of rack 3mm l tooth gap 10 Finally lower the operator 3mm to achieve the required 3mm tooth clearance L OMNANAAM V _NNnNAEREZAEZBREIIINII NIN 11 Ensure that operator mounting bolts are securely tightened page 22 NN 23 Steel rack 1 Fix rack using the steel angle brackets provided 2 Brackets must be spaced no more than 300mm apart 3 When joining different lengths of steel rack a simple way of ensuring correct pitch spacing is to clamp a small off cut between the two pieces RAZ rack 1 Fix the RAZ rack to the side of the gate using the TEK screws provided Use the vertical slots in order to allow adjustment 2 Use at least three TEK screws per half metre section of rack TEK screw self drilling and tapping screw page 23 FIGURE 24 FIGURE 26 3 When fitting the RAZ rack it is easier to start on the right and work towards the left 4 The RAZ rack simply clips together Fit additional fixing screw through the horizontal slots to secure the rack to the gate directly above the pinion when the gate is in the closed pedestrian and open positions Nylon angle rack 1 Fix rack to the side of the gate using the TEK screws 2 Ensure that all the mounting holes provided in the angle section are used page 24
57. try to recharge the batteries with power supply units other than that supplied page 3 with the product or by CENTSYS Make sure that the earthing system is correctly constructed and that all metal parts of the system are suitably earthed Safety devices must be fitted to the installation to guard against mechanical movement risks such as crushing dragging and shearing It is recommended that at least one warning indicator light be fitted to every system Always fit the warning signs visibly to the inside and outside of the gate The installer must explain and demonstrate the manual operation of the gate in case of an emergency and must hand the User Guide over to the user Explain these safety instructions to all persons authorized to use this gate and be sure that they understand the hazards associated with automated gates Do not leave packing materials plastic polystyrene etc within reach of children as such materials are potential sources of danger Dispose of all waste products like packaging materials worn out batteries etc according to local regulations Always check the obstruction detection system and safety devices for correct operation Centurion Systems Pty Ltd does not accept any liability caused by improper use of the product or for use other than that for which the automated system was intended This product was designed and built strictly for the use indicated in this documentat
58. uirements ee 7 oa _Mains isolator switch INI Ln Afita M 0H HIE ION i di i di di l dl AE Cis m HD dii DENEN AA di dile i di 1e L Ton EPAL Ni IDEEN OI di IdInmLIL IT di Hoc n ter ww MaA a i IAI E Mess d Ter E wey ORT TY di ALa BE et Adi IM 34 E ha B m 3 tr Pea U f gt n oo aa CET Cr tr Di o p CX NY NY NY a Cr Cr NY c RN RN Ng NN NN FIGURE 6 CABLING REQUIREMENTS Legend A 1 220 240V AC mains cable via double pole mains isolator switch 3 core LNE 1 5mm SWA 2 Optional intercom cable from motor to dwelling n1 6 core 0 5mm multi stranded 3 Optional intercom cable from motor to entry panel n2 0 5mm multi stranded 4 Optional but recommended infrared safety beams 3 core 0 5mm multi stranded 5 Optional access control device 3 core 0 5mm multi stranded 2 multi stranded OR 6b Optional keypad 3 core 0 5mm multi stranded 7 Optional external radio receiver 3 core 0 5mm multi stranded 6a Optional pedestrian keyswitch 2 core 0 5mm lt gt 8 Optional pillar lights 3 core LNE SWA size according to power requirements 9 Optional ground loop for free exit 1core 0 5mm multi stranded silicone coated nl number of cores required by intercom n2 number of cores required by intercom Possibly increase cable thickness if pillar lights a
59. utton for two seconds FI GURE 49 Select the limits menu by pressing the enter button Gi Follow the onscreen instructions to complete the setup procedure For more details about the Profile operating standard refer to Section 22 Factory defaults schedule page 35 19 How to set up additional features on the D5 Evo controller Section 20 provides the full menu of features that can be set up on the system An explanation of each feature is provided in Section 21 Controller features When setting up the D5 Evo system via the LCD display all the steps that have to be followed are clearly provided via the display It is only necessary to note the following To get into setup mode press the enter aaga button for two seconds and follow the instructions provided from there The buttons provided on the controller for navigating the system are not marked because at each step during the setup the function given to each button is provided on the display Menu level m HH H P Aut aCi ose aan e Exit Go AWUp Dn FI GURE 50 e When not in setup mode i e normal mode the 6 button is used as a test button for operating the system aff The triangular up or down gt buttons are used to scroll through the diagnostic screens For each feature a factory default setting has been programmed into the controller Referred to as an operating standard or profile these defaults have b
60. x Collisions Intermittent IRBC IRBO signals Check that the voltage applied to the beams is appropriate Spurious trigger Intermittent short due to possible moisture on the FRX or Trg inputs Monitor FRX or Trg LED s If the problem is still not solved the main controller might be faulty Gate starts closing Check collision sensitivity and other causes with procedure B then stops and re opens False collision detection page 59 Problem Unreliable Autoclose Possible faults Latching receiver on Trg would activate the Autoclose override feature Long pulse on Trg would activate the Autoclose override feature Faulty IRBC Beam signal Intermittent power loss check for low voltages with procedure A Low battery voltage condition If the problem is still not solved the main controller might be faulty Problem Possible faults Gate takes a few By default the motor would delay opening to pedestrian for seconds before it opens two seconds This time can be changed by altering the value to pedestrian of the Pedestrian pre open delay feature refer to Section 21 Menu 7 3 e The fault is with the receiver e Internal receiver could be locked Gate opens from the Check remotes are correctly learned to the receiver Refer to intercom butnot remotes diagnostic screen for verification via remote control The onboard receiver could be faulty If an external receiver is used check the wiring between the

Download Pdf Manuals

image

Related Search

Related Contents

Creative Labs TravelSound i50  PETL/tET/tPET DIO Series User Manual      レイシーマグネットポンプ RMD 型 取扱説明書  ADDER ADDERLink X50 MultiScreen  Betriebsanleitung Operating instructions Mode d'emploi  Pana30ni竈 〝 取扱説明書  HDS-700  C € 0086 STERIL  

Copyright © All rights reserved.
Failed to retrieve file