Home

WATER TANK USER'S MANUAL

image

Contents

1. _MAKINEX _ MIXING STATION 5 100 5 MANUAL 5 ABOUT THIS MANUAL 3 Key Terms Disclaimer 3 PRODUCT INFORMATION 4 Safety Information 4 e General Safety Instructions 4 e Safety Stickers 5 Warranty 6 8 Product Description and Specifications 9 INSTRUCTIONS FOR USE 10 15 STEP 1 Fitting a Stirrer Mixer 10 STEP 2 Using MS 100 11 12 STEP 3 Pouring amp Placing Mixed Product 13 14 STEP 4 Cleaning 5 100 15 SALES AND SPARES 15 APPENDIX 16 17 SPARE PARTS REFERENCE MS 100 HAZARD ASSESSMENT PROTOOL STIRRER MANUAL WHEN PURCHASED COLLOMIX HAND MIXER MANUAL WHEN PURCHASED E MAKINEX MS 100 Operator s Manual Page 2 of 18 ABOUT THIS MANUAL This manual is designed to provide the user with the information required to operate and maintain the MS 100 Portable Mixing Station correctly and safely Key Terms READ CAREFULLY refers to important information that should be paid READ careful attention CAREFULLY CAUTION indicates a situation that may cause injury or damage to the machine if the user does not follow the instructions WARNING indicates a situation that may cause injury or death if the user CAUTION A does not follow the instructions correctly DANGER DANGER indicates a situation that will cause injury or death if the user does not follow the instructions as written PROHIBITED identifies actions that shou
2. and durable aluminium trolley 18kg Large pivoting bucket Dust and splash reduction cover Top section is detachable to minimise size during transport Locking castor wheel Trolley can be used to transport product and tools on work sites TABLE 2 MS 100 Product Specifications HEIGHT HANDLE ATTACHED Operating 1070mm 1300mm 42 51 inches HEIGHT HANDLE DETACHED Transport 780mm 31 inches OVERALL WIDTH 540mm 21 inches OVERALL LENGTH 626mm 25 inches LENGTH OF HANDLE ADJUSTMENT 250mm 10 inches WEIGHT WITHOUT STIRRER MIXER 18kg 40165 25kg 5508 weight may vary if used WEIGHT WITH FESTOOL STIRRER with other Stirrers Mixers 24kg 53105 weight may vary if used WEIGHT WITH COLLOMIX HAND MIXER with other Stirrers Mixers MAKINEX MS 100 Operator s Manual Page 9 of 18 INSTRUCTIONS FOR USE Do Not Operate the MS 100 without wearing the appropriate personal protective equipment PPE including appropriate footwear WARNING Assess the surrounding area for hazards ALWAYS seek appropriate First Aid if Injury Poisoning or Irritation occurs WARNING Que to contact with Materials and Substances A ALWAYS ensure that the work place is well ventilated CAUTION STEP 1 Fitting a Stirrer Mixer to the MS 100 Ensure the Stirrer Mixer is disconnected from mains power before Attaching WARNING 0 Removing it to from the MS 100 frame NEVER place hand under Drill Clamp Clamp Arm2 when adju
3. labour or replace the machine under warranty All warranties will be carried out by MAKINEX authorised staff or appointed agents at premises to be determined by the Manufacturer tis the responsibility and cost of MAKINEX or our appointed agent to return the machine to be repaired or replaced under warranty to the consumer this is valid for domestic territories only e g machine purchased in USA will repaired replaced under warranty and returned to the USA consumer Machine purchased in Australia will be repaired or replaced under warranty and returned to the Australian consumer machine purchased in Europe will be repaired or replaced under warranty and returned to the consumer of that specific European nation etc Where the specific warranty component e g Mixer Stirrer is under a Manufacturer s warranty other than MAKINEX e g Collomix Festool etc the consumer can either contact MAKINEX or the applicable Manufacturer for repairs where such warranty was registered with that manufacturer at purchase Warranty calls will only be carried out by our representatives and not via client s choice of repairer We will not accept back charges for any work not carried out by our representatives or accept any charges due to equipment being un operational for any reason even during its warranty period MAKINEX MS 100 Operator s Manual Page 7 of 18 WARRANTY CONTACT INFORMATION AUSTRALIA Tel 61 2 9460 8071 Fax 61 2 9439
4. 9815 d lobban makinex com au 15 Waltham St Artarmon NSW 2064 AUSTRALIA USA Tel 407 446 1966 407 826 0000 soencer makinexusa com m spencer makinexusa com EUROPE Tel 31 0 6 24881203 31 0 6 50841849 SERVICE amp PART ORDERING For service and ordering parts please call AUS 1300 795 953 or 61 2 9460 8071 USA 407 446 1996 407 826 0000 EUROPE 31 0 6 24881203 or 31 0 6 50841849 Or your nearest MAKINEX distributor We have very knowledgeable experienced staff to assist you with help and advice MAKINEX MS 100 Operator s Manual Page 8 of 18 Product Description and Specifications MS 100 is the ultimate mixing station for all self levelling cement and compounds producing a perfect mix every time Designed by contractors for contractors it provides efficient hands free mixing and fast precision pouring of materials saving time and effort on jobs One MS 100 mixing station can mix up to 80kg in 3 minutes which can equate to 1 Tonne per hour MS 100 is ultra lightweight for easy transportation and the ergonomic design with easy tilt operation provides control and speed for precision pouring The MS 100 will suit various Stirrers Mixers please contact your retailer for more information A Festool Stirrer or Collomix Hand Mixer are optional and sold separately both models feature variable speeds and are fully detachable from the MS 100 MS 100 Features e Hands free mixing Built in timer 4 wheel mobility Light
5. ALWAYS wind up the Power Cord before moving the MS 100 WARNING ALWAYS be aware of the Power Extension Cord position when working around the 5 1007 Maximum SAFE Load 60 80kg 132 176lbs of wet levelling compound DO EXCEED 80kg 176165 CAUTION ALWAYS use correct lifting technique when loading materials 1 Ensure Stirrer Mixer is firmly secure in the Drill Clamp 2 Attach Lid to Bucket 3 Make sure the Locking Pin is engaged i e locked to prevent the bucket from pivoting at the base of the Bucket and that the Castor Wheel Brake has been applied 4 Pour in correct amount of water for desired mix quality refer to Levelling Compound manufacturer s recommendations 5 Protool Stirrer Make sure Stirrer is Collomix Mixer Make sure Mixer is switched to High Gear 2 and Variable switched to low speed Speed Dial is set to 1 6 Plug in Stirrer Mixer to Mains Power 7 Press Trigger to turn ON Stirrer Mixer and lock in Trigger 8 Start adding Bags of Levelling Compound one at a time 9 Protool Stirrer After 2 3 of Levelling Collomix Mixer Leave speed on low Compound has been added to the mix setting start to increase the Variable Speed Dial 10 Protool Stirrer After final Bag of Collomix Mixer After final bag of Levelling Levelling Compound has been added Compound has been added switch drill to turn Speed Dial to Maximum Power high speed CAUTION When changin
6. UCTION PRODUCTS W makinex com E sales makinex com SERVICE amp PART ORDERING For service and ordering parts please call AUS 1300 795 953 or 61 2 9460 8071 USA 407 446 1996 EUROPE 31 0 6 24881203 or 31 0 6 50841849 Or your nearest MAKINEX distributor We have very knowledgeable experienced staff to assist you with help and advice W makinex com E sales makinex com MAKINEX 5 100 Manual Page 15 of 18 APPENDIX SPARE PARTS REFERENCE MS 100 HAZARD ASSESSMENT PROTOOL STIRRER MANUAL WHEN PURCHASED COLOMIX HAND MIXER WHEN PURCHASED am ue MAKINEX MS 100 Operator s Manual Page 16 of 18 APPENDIX 1 SPARE PARTS REFERENCE 5 j LIN DESCRIPTION i BASE FRAME SIDE POST Ht 8 g S SIDE PLATE BASE BACK EI T dE 1 gt PLUNGER iy uz ET E h co se RIVET 3 16 X 3 B 44 5 09 01 SAFETY STICKER STKCEER i 1 Z e ele fa ea epeles sese e ep ENAKINE eee OPTIONAL DRILL AND STIRRER ILL PART Sydney Head Omce Ph 1300 795 953 15 Waltham St Fax 02 9139 9815 REM CE PROTOOL MX 02 1 1 COIT HE i PROJECT MIXING STATION PRODUCTION 3 2013 I wena wen Re MIXING STATION explode
7. an unstable surface CAUTION A ALWAYS protect open drains nearby from spillages of Compound CAUTION Check the Locking Pin is engaged i e locked to prevent the bucket from pivoting at the base of the Bucket Disengage Castor Wheel Brake Wheel MS 100 to the desired area use caution when moving the Loaded Bucket Disengage unlock Locking Pin at the base of the Bucket Using a controlled motion use the MS 100 Handle and Pouring Handle pour mixed Levelling Compound where required oo Tu NOTE With two MS 100 Portable Mixing Stations another mix could be completed using the same Stirrer Mixer while one is being poured MAKINEX 5 100 Operator s Manual Page 14 of 18 STEP 4 Cleaning the MS 100 ALWAYS use two people when loading and unloading the 5 100 CAUTION 1 very important to clean the equipment after use Use water or a high pressure hose to clean all Levelling Compound from the MS 100 Frame Wheels Bucket and Stirrer Mixer paddle after use Extra attention should be focused on cleaning the Wheels Wheels should be oiled greased regularly For maintenance on Stirrer Mixer please refer to the manufacturer s manual PII Please refer to www worksmartequipment com au for product usage videos NOTE and for more information SALES amp SPARES For sales and spare parts for all MAKINEX products please refer to your local distributor CONSTR
8. d parts SEEPARTS 1527 05 MAKINEX 5 100 Operator s Manual Page 17 of 18 CONSTRUCTION PRODUCTS W makinex com sales makinex com MAKINEX 5 100 Manual Page 18 of 18
9. g gear settings on the Collomix Mixer turn the Mixer off before changing the gear Changing gears while the Mixer is running CAUTION may damage its gearbox 11 Wait for 30 seconds as Compound is mixed turn OFF Stirrer Mixer temporarily Protool otirrer Turn speed dial to 1 before switching OFF at the Trigger then disconnect from mains power and scrape off any excess powder that has gathered around the top of the bucket 12 Switch Stirrer Mixer back ON and return to Maximum Power until Levelling Compound is mixed to a lump free consistency MAKINEX 5 100 Operator s Manual Page 13 of 18 13 Protool Stirrer Once equal consistency has been achieved turn down Variable Speed Dial to 1 and switch OFF Stirrer at the Trigger Collomix Mixer Once equal consistency has been achieved turn off the Mixer 14 Unplug Stirrer Mixer from Power Supply wind up the Power Cord on the MS 100Handle Trigger amp li High Low Trigger Lock ESSI Gear Selector High Low Gear Selector i D nun N 3 UV N j 4 INN A 7 Td Trigger amp Trigger Lock STEP Pouring and Placing Levelling Compound ALWAYS check that Power Cord is secured around the MS 100Handle CAUTION before Pivoting the Bucket NEVER place hand near the Pivot Pin Pivot Point when rotating the CAUTION Bucket A NEVER move or operate the fully loaded 5 100
10. here to all Instructions on the Unit It is forbidden to remove any safety or instructional stickers or panels from PROHIBITED 2 5 100 Read all safety and instructional stickers displayed on each component of READ the MS 100 CAREFULLY MAKING SAFTEY OPERATING INSTRUCTIONS Wear appropriate personal protective equipment Use caution when changing attachments Ensure stirrer is switched off before connecting or disconnecting from power supply Use a dedicated mains power supply with extension lead not exceeding 10m Never place hands in bucket while the stirrer is operating MAKINEX 5 100 Manual Page 5 of 18 Warranty WARRANTY Ex factory Reseller premise MAKINEX warrants to the original purchaser MAKINEX provides a Limited One Year Warranty that applies to MS 100 Mixing Station only this excludes the Stirrer mixer and any other attachments and consumables e Any unauthorized repair or part replacement will void warranty Refer to manufacturer for all repairs e Regular service must be carried out by competent persons only failure to comply will void warranty e All wheels needs to thoroughly cleaned after each use failure to do so will void warranty olirrer Mixer where purchased is to be covered by original manufacturer Please refer to their manual for more information Transportation charges on product submitted for repair or replacement under this warranty are the sole res
11. ld never be carried out by PROHIBITED 2017012 interacting with the equipment Disclaimer Makinex and its affiliates takes no responsibility for any damage injury or death resulting from the incorrect or unsafe use of this machine Use of this machine should be undertaken by competent persons only It is the operators responsibility to ensure that the following safety procedures are followed If you are unsure do not operate this machine MAKINEX 5 100 Operator s Manual Page 3 of 18 PRODUCT INFORMATION Safety Information General Safety Instructions Throughout this document there are several safety warnings The user should read through this complete document before using the MS 100 Ensure you read all information contained in this manual before using the READ MS 100 CAREFULLY G gt Ensure you read the User Manual and safety instructions for the MS READ 100and other components that are part of this unit CAREFULLY See Appendix for more information Always wear the recommended personal protective equipment PPE Do not expose power tools to rain or wet conditions Water entering a DANGER power tool will increase the risk of electric shock PROHIBITED MAKINEX 5 100 Operators Manual Page 4 of 18 Safety Stickers There is a safety and information panel provided on the Clamp Arm see images below of the MS 100 to alert the user of potential safety risks hazards Please read and ad
12. ponsibility of the purchaser This warranty only applies to the original purchaser and is not transferable Warranty Exclusions e Warranty does not cover wear and tear breakage misuse or theft e Warranty does not cover consumables e g bucket and lid wheels and attachments Mixers Stirrer e Warranty will not apply to parts and or labour if this the Mixing Station is deemed to be misused neglected installed improperly or set up incorrectly Warranty Exclusions e Cosmetic defects such as decals and coating e Failures due to acts of God and other force majeure events beyond the manufacturer s control e Problems caused by parts that are not original MAKINEX parts Responsibility of the consumer under this Limited Warranty Strict adherence to the maintenance checks and schedule with proof of scheduled maintenance service required by an authorised agent or qualified mechanic Maintenance services are not covered under warranty 16 the consumer s responsibility to deliver the machine in question to our service premises or to the premises of our appointed agent at the consumer s expense for replacement or repair as applicable MAKINEX MS 100 Operator s Manual Page 6 of 18 Claim Procedure Contact by phone or email informing us of your machines problem or defect Once the extent of the claim has been assessed we retain the right to compensate the consumer for such defect or repair parts amp
13. sting the CAUTION height 1 Refer to the Appendix for exploded assembly diagram 2 Check that the Castor Brake has been engaged MAKINEX 5 100 Manual Page 10 of 18 3 Attach MS 100 Clamp Arm into the Slide Arm Collar of the MS 100 Frame tighten Collar Latch in place Go to step 5 if already in place Clamp Arm 7 Slide Arm Collar ey 4 If fitting a Collomix Mixer ensure the Collomix insert is seated in the drill collar 5 Ensure the Drill Clamp Latch is open and insert the Mixer Stirrer through the slot MAKINEX 5 100 Manual Page 11 of 18 6 Rotate the Drill Clamp Latch back around the Drill Clamp 7 Position Stirrer Mixer in the Drill Clamp always hold Stirrer Mixer by its grab handles when positioning If fitting the Protool Stirrer ensure the Variable If fitting the Collomix amp Mixer ensure the opeed Dial is facing away from the MS Electrical Cord is facing to back of the 100Handle 5 1007 8 Tighten Drill Clamp Latch firmly to lock Stirrer Mixer MAKINEX 5 100 Manual Page 12 of 18 STEP 2 Using your 5 100 NEVER place hands into the Bucket whilst Stirrer Mixer is Mixing ALWAYS disconnect Stirrer Mixer from mains power before placing hands WARNING into the Bucket ALWAYS ensure the Stirrer Mixer is switched OFF before plugging it in

Download Pdf Manuals

image

Related Search

Related Contents

Manuel d`utilisation K 1300 S année 2009  Honeywell HZ-2016 User's Manual    Hi-CR デラックス300G  Enjoy Listening  Manual KP  SERVICE MANUAL/INTEGRATION SPLIT TYPE  A B 取扱説明書  SysLab Manuel  

Copyright © All rights reserved.
Failed to retrieve file