Home
        user Manual
         Contents
1.   HEMELO          SS  ChemfloPlus Water  Management System   OFFICES   AUSTRALIA OFFICES   OVERSEAS  NSW   SYDNEY WATERCO  EUROPE  LIMITED WATERCO    LIMITED   HEAD OFFICE  Sittingbourne  Kent  UK Guangzhou  China  Tel   61 2 9898 8600 Tel   44  0  1795 521 733 Tel   86 20 3222 2180  QLD   BRISBANE WATERCO FRANCE WATERCO  FAR EAST  SDN BHD  Tel   61 7 3299 9900 Saint Priest  France Selangor  Malaysia   Tel   83 4 72 79 33 30 Tel   60 3 6145 6000  VIC TAS   MELBOURNE  Tel   61 3 9764 1211 WATERCO  USA  INC PT WATERCO INDONESIA   Augusta  Georgia  USA Jakarta  Indonesia  WA   PERTH Tel   1 706 793 7291 Tel   62 21 4585 1481  Tel   61 8 9273 1900   WATERCO CANADA WATERCO SINGAPORE INTL PTE LTD  SAVNT   ADELAIDE Longueuil  Quebec  Canada Nehsons Building  Singapore  Tel   61 8 8244 6000 Tel   1 450 748 1421 Tel   65 6344 2378  ACT DISTRIBUTION WATERCO  NZ  LIMITED  Tel   61 2 6280 6476 Auckland  New Zealand    Tel   64 9 525 7570    E A Z A E Ff vy 7 YN E G Z A EE n aa al    ERY     warr wy Afa EA MAAS     water  the liquid of life www waterco com     ZZM1465  12 2014    ASSOCIATION    QUALITY              Waterco Limited ABN 62 002 070 733       Waterco ChemfloPlus   pg 01      DONICNtS parsu meso    e Mounting brackets  top and bottom  e Multi electrode  probe     e ChemfloPlus Power Supply and Mains Cable  Me E a nnn 01    e Tubing  BQ                                     03 e Dual peristaltic pump module  INITIAL POOL BALANCE                                   220  2220   09 e 
2.  off   the SWC unit must be capable of functioning in this manner and should be set  to manual operation only  not automatic      INSTALLATION GUIDE    Choosing a good location    The ChemfloPlus is manufactured from weather resistant materials and is designed for operation  in full sun and rain  However  your ChemfloPlus will benefit if it is protected from the weather   The ChemfloPlus Power Supply should not be mounted close to where chemicals are stored   eg acid and chlorine  as vapours from these chemicals are corrosive and may damage the  electronic controls within the unit     Insect intrusion  particularly ants  can cause problems with all equipment  Ensure that the pool  equipment area is kept free of insects as much as possible  Insect intrusion is not covered  under the warranty     Installing the ChemfloPlus Controller    Locate the ChemfloPlus Power Supply close to the filtration pump so that it may be connected  easily  Connect the ChemfloPlus Power Supply to the mains power outlet of the pool area and  make sure this outlet meets all applicable Australian Standard at the time of installation     Mount the ChemfloPlus Power Supply at least 1 5m above the ground and at least 3m from  the pool water  A mounting template has been provided with the ChemfloPlus that shows you  where to place screws on either a wall or post     The PUMP socket outlet in the base of the ChemfloPlus Power Supply is dedicated to the  filtration pump only  Do not use a double adaptor to 
3.  press Y UP to allow automation of both systems     When both systems are enabled the chlorine dosing is designed to only dose when the ORP  has fallen far below the set point  This means that the chemical dosing will occur at times of  high demand     Adjust ORP Control ON or OFF    To disable the ORP System  or re enable it if it has been disabled  you need to access the  ORP menu and work your way through the MANUAL FEED  SUPER CHLOR and ADJUST SET  POINT questions     pressing the N DOWN button in response to each question     The LCD will then read    ADJUST ORP CONTROL TURN OFF  Y N     if the system is ON  or  ADJUST ORP CONTROL TURN ON  Y N     if the system is OFF   If you press Y UP  the system  will turn on  or off depending on its current status   If you answer N DOWN to either question   the LCD will return to the home screen     e a    Waterco ChemfloPlus   pg 13    pH MENU    Accessing the pH Menu    Access the ChemfloPlus Menu System by pressing ENT  Use the Y UP or N DOWN button to  scroll through the main menu until DH MENU is displayed on the LCD  Press ENT to select     Manual Feed    Having accessed the ORP menu  the LCD will ask    Manual Feed Y N      Press Y UP to select  and the display will read    FEED 5 mins 75mL        You can increase the amount of the dose by pressing the Y UP button until the desired dose  amount is displayed   Note  the dose volume displayed is an estimate only     Press ENT and the peristaltic pump will commence feeding liqui
4. ON MANIFOLD   FOLLOWING   FLOW DIRECTION     CELL INSTALLATION  BE INSTALLED    e THE CELL MUST    BE INSTALLED IN EITHER OF THE    PUMP AFTER THE POOL HEATER   FOLLOWING FLOW DIRECTION   SWIVEL MUST ALWAYS BE  ARRANGEMENTS BELOW    LOCATED IN A VERTICAL    e THE WHITE CAP WITH INJECTION  POSITION    e THE INJECTION MANIFOLD CAN    Chemical drums    Position the chemical drums in a safe and secure location  preferably about 2 metres from the  ChemfloPlus  Ensure you have the right chemicals for your pool and that chemicals have been  diluted if necessary  Always take great care when dealing with the chemicals     Installing the Peristaltic Pumps  Dosing Pump Models     Mount the peristaltic pumps unit adjacent to the ChemfloPlus Power Supply  as it is hard wired  to this power supply     Cut lengths of tubing that will reach from the base of each peristaltic pump to the injection  manifold  Connect one end of the tubing to the outlet side of the peristaltic pump  the direction  of flow is indicated by an arrow on the front cover of the pump   Connect the other end of the  tube to the injection point on the injection manifold     Cut another length of tubing that will reach from the base of the peristaltic pump to the base of  the acid drum  Position the acid drum in a safe and secure location  preferably about 2 metres  from the ChemfloPlus     Connect the one end of this tube to the inlet side of the peristaltic pump  the direction of flow is  indicated by an arrow on the fr
5. User Manual  INSTALLATION GUIDE  amp  DIAGRAMS                                09 e Injection manifold  FROMM I aaao 10 e Mounting hardware  raw plugs  screws and paper template   NAVIGATING THE MENU SYSTEM                                   10  TIMER MENU                                                           10  OPP MENU ao ae 09 IMPORTANT SAFETY MEASURES   a n e Always add concentrated chemicals to water     not the other way around   STATUS INDICATOR  WARNINGS AND                              10 e Don   t allow chemicals to mix   dangerous  highly corrosive fumes produced   aren OWNS e Always wear protective clothing  footwear  gloves and eye protection when handling pool   RII TIE NANCIE   a la 10 chemicals to avoid injury   TROUBLESHOOTING                                                  10 e If a spill occurs  wash the affected area with fresh water immediately and seek medical  attention   e Work in a well ventilated area and avoid inhalation of fumes   e Read and follow safety instructions on chemical drums   IMPORTANT     If the power cord is damaged the unit must be returned to  Waterco for repair     Always read the instructions and warnings on chemical containers before using  chemicals     Begs Teed PN PINNED tee ore re ces ee ca casencncccescncusencnscseecnsceseccscescececsececsssscenss    26     SUE  Lee   een eee ler    Tee S8 cana       HOW IT WORKS     The ChemfloPlus continuously analyses pool water chemistry while your pool system is running   The base m
6. and following the prompts  on the LCD  If you find you have ended up in a part of the Menu system unintentionally  you can  return to the Home Screen by pressing the ESC OFF button at any time     Use the Y UP and N DOWN buttons to scroll through the various menu options until the desired  option is displayed on the LCD  Use the ENT button to confirm that you wish to select that  option     Once accessed  use the Y UP and N DOWN buttons to adjust operational settings up or down     and confirm adjustments by pressing ENT  To cancel any adjustments  simply press ESC OFF  to return to the Home Screen     Advanced Settings Menu    The Advanced settings are accessed by holding down the ESC OFF button for 4 seconds   ADVANCED MENUS will appear in the display     press ENT to enter   Some of the Advanced Settings comprise     e POOL   used to store information on pool volume and whether it is concrete or fibreglass  e SYSTEM DATA   shows service information    e FILTER CYCLES   allows for up to 4 Filter Cycles to be activated and is very useful for  seasonal timer adjustments     e AUX   controls timed operation of auxiliary power outlet  e FULL MANUAL ON or AUTO TIMER ON   use when the ChemfloPlus is being run as a     slave    to another controller     It should be noted that some of these settings can affect the basic operation of the unit and are  for the use of technicians     if in doubt do not make any changes        TIMER MENU    Setting the time    Once you have installed 
7. connect another pump as this will overload  the system and void warranty     Your ChemfloPlus has two other power outlets on its base  which can be used to run lighting  or an SWC unit  or other pool equipment   These outlets are also timed  so accessories can be  set to come on and turn off automatically     Installing the Injection Manifold    The injection manifold should be installed on the return  pressure  side of the pump  after  accessories such as heater  but before the chlorinator cell if fitted  It can be plumbed in as an  elbow or an in line fitting  Ensure that the water flow is in the correct direction  as marked on  the injection manifold      Installing the Probe into the Injection Manifold    The probe has a bayonet fitting  To install the probe  simply insert it into the injection manifold  and twist to lock the bayonet fitting  Ensure that the o ring seal is not twisted or out of place         lt   as  O      Q  Z  O   lt    l   lt   _  V           CONTROL POWER CONNECTIONS    RED GPO      POOL PUMP    SALT WATER CHLORINATOR  AUXILIARY DEVICE    GREEN GPO  BLACK GPO    DOSING PUMP SYSTEM INSTALLATION  e POSITION DOSING PUMP AS CLOSE    INJECTION MANIFOLD INSTALLATION  e THE INJECTION MANIFOLD MUST    AS POSSIBLETO INJECTION MANIFOLD    OR TAPPING BAND  e MOUNT PUMP 450mm   1500mm OFF    BE INSTALLED ON THE OUTLET   PRESSURE SIDE OF THE POOL    s  msSaLt CHLORINATOR       Waterco ChemfloPlus   pg 05    ABOVE THE HEIGHT  OF THE FILTER   AND AFTER THE  INJECTI
8. cycle  Adjust  the OFF time in the same way as the ON time and press ENT to confirm     After ON and OFF times for the first filter cycle have been adjusted  the ON time for the second  filter cycle is shown on the LCD  This can be adjusted in the same way  or if you do not wish to  make any changes  simply press ENT to confirm the time shown on the LCD  Follow the same  process to either adjust or confirm the OFF time for the second filter cycle  and once this has  been confirmed the LCD will display the home screen     Waterco ChemfloPlus   pg 11    Running Times    We recommend your system be operated for at least 4 hours per day and always run the  system when using the pool     As sunlight destroys chlorine  it is recommended that the ChemfloPlus be run mostly in the  evening     Chlorine is added for sanitation but the filter is needed to remove pollutant particles  dust  sand  etc  and keep the water looking good  The filter must operate for a reasonable number of hours  per day to remove pollutants If there are adverse local conditions     such as windborne dust and  debris   the chlorine demand will be higher than normal and you will likely need to operate the  system for longer periods to adequately filter the water     Optional LIGHT Timer Sub Menu    You can use your ChemfloPlus to turn your pool or garden lighting on and off automatically  you  can set the ON and OFF times using the light timer menu     Press ENT to access the ChemfloPlus Menu system  Press ENT a
9. d chlorine     Adjusting the Set Point    The pH Set Point is the pH that the ChemfloPlus will adjust your pool water to  You can adjust  the pH Set Point via the pH Menu     Enter the pH Menu as described above  and press the N DOWN button when asked whether  you wish to do a manual feed  The LCD will then read    ADJUST SET POINT Y N     Press Y UP  to select this option and then the LCD will display the current set point  Adjust this using the  Y UP or N DOWN buttons  Confirm the adjusted set point by pressing ENT  The new set point  will then be displayed on the right hand side of line 3 of the LCD     Calibration and Re setting Factory Defaults    If your ChemfloPlus consistently displays a pH reading different from that obtained by manual  testing with a quality test kit  it may be necessary to re calibrate the multi electrode  probe    The instructions below assume the probe is measuring a pH of 7 8     Caution  do NOT re calibrate the probe until identical pH readings have been obtained  from at least three tests from around the pool  You will need to calibrate the probe to the  pH value obtained from these test kit results     Enter the pH menu as described previously and press the N DOWN button when asked whether  you want to do a manual feed  and then again when asked whether you wish to adjust the set  point     The LCD will then read    CALIBRATE PROBE      Press Y UP to select this option and the LCD  will read    PROBE Ph   7 8 ADJUST TO  0 0     Use the Y UP b
10. ectrode  Probe     If the ChemfloPlus is consistently giving readings different from those obtained from a test kit   it may be necessary to clean the multi electrode     To do this    e Remove the probe from the injection point by twisting the bayonet  or if fitted with a tapping  band  by unscrewing the retaining nut  and remove the o ring    e Holding the cable  gently swirl the probe in a dilute solution of hydrochloric acid  pool acid   for two minutes   e Rinse the probe in clean water and then replace it in the injection point  making sure that the     o ring    is in place    e Twist bayonet to lock  or tighten nut with fingers     TROUBLE SHOOTING    If there appears to be low or no Chlorine Residual    1  Check stabiliser level is 40ppm     6O0ppm  Add if necessary and wait for it to dissolve   2  Have you added any chemical additives recently    3  Check pool for phosphates and remove if necessary   4  Is the unit turned on and operating the filter pump   5      If the unit is not running at all  check the fuse in the bottom of the unit     Operation Following a Power Failure    The ChemfloPlus unit comes with a timer function built into the operating software  The timer is  a 24 hour type with quartz crystal control  This Timer is backed up by a Real Time Clock  RTC   similar to those found in computers     During a power failure the ChemfloPlus will keep time and maintain AutoMode functions     If a Filter Cycle is active when power is returned the pump will be t
11. ed on the LCD  Press ENT to select     Manual Feed    Having accessed the ORP menu  the LCD will ask    Manual Feed Y N      Press Y UP to select  andthe display will read    FEED 5 mins 75mL        You can increase the amount of the dose by pressing the Y UP button until the desired dose  amount is displayed   Note  the dose volume displayed is an estimate only     Press ENT and the peristaltic pump will commence feeding liquid chlorine     Adjusting the Set Point    The ORP Set Point is the value in millivolts that the ChemfloPlus will adjust your pool water to   You can adjust the ORP Set Point via the ORP Menu     Enter the ORP Menu as described above  and press the N DOWN button when asked whether  you wish to do a manual feed and then again when asked if you wish to do a superchlorination   The LCD will then read    ADJUST SET POINT Y N     Press Y UP to select this option and then  the LCD will display the current set point  Adjust this using the Y UP or N DOWN buttons   Confirm the adjusted set point by pressing ENT  The new set point will then be displayed on  the right hand side of line 3 of the LCD     SWC  AUX  Settings     for control of a Salt Water Chlorinator    The SWC  AUX  is off by default  To turn it ON simply press Y UP  You will then be prompted to  keep the chlorine dose pump ON too  If you only require the SWC unit to be enabled press N   DOWN to disable the automatic chlorine dosing pump   note that it is still available for manual  dosing  Otherwise
12. gain to select the TIMER  menu and then scroll down using the N DOWN button until LIGHT MENU is displayed on the  LCD     Line2 on the LCD will now read    AUTO  Y N    To enable automatic light operation press the Y   UP button  Line2 will read    Auto ON    for short period before displaying    ON hh mm        Adjust the ON time using the Y UP and N DOWN buttons and confirm by pressing ENT  The  LCD will now prompt you to set the OFF time  which is accomplished using the Y UP and N   DOWN buttonsas before  Press ENT to confirm the new OFF time and the LCD will return to  the home screen     To disable automatic light operation  access the LIGHT menu in the way described above  and when asked    AUTO  Y N      press the N DOWN button  Line2 will read    Auto OFF    for  short period then the system will return to normal operation and the light can only be operated  manually  See below for how to do this      Manual Light Operation    If the ChemfloPlus is turned on  the light can be turned on or off manually by pressing the Y   UP button     If you have multi coloured LED lights that cycle through different colours and requiring a power  pulse to change effects  you can hold down the Y UP button to cycle through the options and  release when the desired colour or effect is achieved        ORP  Chlorine Menu     Accessing the ORP Menu    Access the ChemfloPlus Menu System by pressing ENT  Use the Y UP or N DOWN button to  scroll through the main menu until ORP MENU is display
13. ne 3 tells you that the current ORP is 670mV with the unit set  to provide 650mV    Line 4 displays pH information   In the example above  line 4 tells you that the current pH is 7 5 with the unit set to  provide 7 6     CHEMFLOPLUS OPERATIONAL BUTTONS    Your ChemfloPlus has 5 buttons that allow you to control the various functions available via the  ChemfloPlus Menu system     Optional  Pool Light  ON OFF       Each button is labelled with its primary function either on the button itself  or adjacent to it   Secondary functions are labelled within a curved white outline next to the relevant button     The buttons are backlit to show which are active at any given time  although the ESC OFF  button is always available to take you back to the home screen     ON Button    Turn the System On Manually    Press the ON button once to switch the ChemfloPlus and the pool pump on manually  The  ChemfloPlus will default back to AUTO and turn itself off automatically at the end of the next  programmed FILTER CYCLE  and this time will be displayed on the LCD         Increasing Manual Run time in Hourly Increments    Press the ON button repeatedly  or hold the button down  to increase the manual run time  in hourly increments  The run time is displayed on the LCD  When the desired run time has  been reached  press the ENT button to confirm your selection and the system will commence  operation     ESC OFF Button    Turn the System Off Manually    If the ChemfloPlus and pool pump are runni
14. ng  pressing this button will turn them off manually   The ChemfloPlus will automatically turn on again at the start of the next FILTER CYCLE  and  this will be displayed on the LCD      Return to Home Screen    If you have unintentionally accessed a ChemfloPlus Menu that you don   t actually require   pressing the ESC OFF button allows you to return to the home screen at any time     ENT Button    Use this button to enter the ChemfloPlus Menu system and to access the various options in  each Menu  Use the Y UP and N DOWN buttons to scroll through menu options and when your  desired menu option is displayed on the LCD  press ENT to access that option     Y UP Button and Optional Pool Light    If you have accessed the ChemfloPlus Menu by pressing the ENT button  press the Y UP  button to scroll upwards through the various menu options  Some menu options will prompt a  yes or no answer  If you wish to answer    yes     press the Y UP button     If your ChemfloPlus also controls your pool lighting  optional   you can turn the lights on or off  manually by pressing the Y UP button  For multi coloured lights  hold the Y UP button down to  cycle through the various colours and release once the desired colour is reached     Waterco ChemfloPlus   pg 09    NAVIGATING THE CHEMFLOPLUS MENU SYSTEM    There are three aspects to the general ChemfloPlus Menu system     the Timer Menu  the ORP   Chlorine  Menu and the pH Menu     Access the ChemfloPlus Menu system by pressing the ENT button 
15. odel has two dosing pumps that dose liquid chlorine and acid to the pool water flow  in response to the water analysis from the probe     The ChemfloPlus can also be used to control a Salt Water Chlorinator  SWC  with and without  extra available dosing from the chlorine dosing pump  The chlorine dosing pump is always  available for manual dosing     When both the SWC and the chlorine dosing pump are enabled the dosing pump is activated  at an ORP approximately 50mV below the set point  It will then will dose regularly until the ORP  climbs to a point that the SWC can take it the rest of the way  This results in the doser only  covering extra high chlorine demands     Note  the filter system should always be running when the pool is being used     Oxidation Reduction Potential    The ChemfloPlus measures how much chlorine is in pool water by measuring the ORP of the  water     ORP stands for Oxidation Reduction Potential  Chemicals like chlorine destroy pathogens  eg  harmful bacteria  in water by oxidising them     The level of oxidation available in the water can be measured chemically with an ORP sensor  contained in the ChemfloPlus   s multielectrode  probe   This produces a voltage related to the  ORP of the water  which is a measure of the effectiveness of chlorine in the water     Varying the ORP will affect how long it takes to destroy harmful bacteria in pool water  For  example  if ORP is maintained at 650mV  E coli type bacteria will be destroyed in around one  sec
16. olved Solids  TDS     There is no simple way to reduce high chlorine levels quickly  However  chlorine levels will  eventually reduce over days  or weeks   particularly if the pool is exposed to sunlight     Low pH    Excess Acid     If the pH of the water drops below the set point  a red status indicator will be illuminated and  the words    LOW pH    will be displayed on the LCD     The ChemfloPlus will automatically prevent any further acid being added to the pool until the  pH is brought back into the correct range by the addition of sodium carbonate or sodium  bicarbonate     Possible causes include     Manual overdosing   Excessive rainfall   Faulty peristaltic pump   The multi electrode  probe  may require cleaning  see page 17 for details   Low Total Alkalinity   Poor pool water circulation    Safety Shutdown    If the pH falls below 5 8 the ChemfloPlus will shut down pump operation to ensure no more  acid gets into the pool     High pH      Insufficient Acid   If the pH rises significantly higher than the set point  a red status indicator will be illuminated  and the words HIGH pH will be displayed on the LCD     Note that a high pH can drastically reduce the ORP of the pool water  and therefore reduce the  effectiveness of the sanitiser  It is important to restore the pH balance as soon as possible by  adding acid to the pool     Possible causes include   e The acid drum is empty  e The pool has been superchlorinated recently  e The pool has a new plaster lining  ve
17. ond  However  if the ORP is lowered to 550mV  the same organisms may take up to 2 hours  to be eliminated     PH Control    When chlorine is added to water the pH always changes   this is because chlorine is not a  neutral chemical  The pH will slowly rise as chlorine is added to the water  A rise in pH greatly  reduces the effectiveness of the chlorine as a sanitiser  so it is important to ensure that the pH  remains in the correct range     The pH of the water can be lowered by the addition of acid     and your ChemfloPlus does this  automatically  The ChemfloPlus multielectrode  probe  measures the pH of the water and doses  the pool with small amounts of acid to keep the pH in the correct range     Waterco ChemfloPlus   pg 03    INITIAL POOL BALANCE    Before you begin using the ChemfloPlus make sure your pool water is balanced as follows     Chlorine    If it is a new installation  add enough chlorine  liquid or granular  to achieve a reading of 3ppm  on an appropriate test kit     Stabiliser    If the pool is outdoors  it is vital that stabiliser  also known as cyanurate and cyanuric acid  be  added and maintained at 40ppm to 60ppm  This compound reduces chlorine destruction due  to sunlight  However  too much stabiliser will reduce the effectiveness of chlorine and can  result in poor quality water so ensure stabiliser does not exceed 80ppm     Good stabiliser level Keeps good chlorine levels and reduces maintenance     OH  For chlorine to be effective  the pH must be 
18. ont cover of each peristaltic pump      Drill an 8mm hole in the lids of the chemical drums and pass the tubing through the hole in the  drum lid  Place a sinker on to the end of the tubing that will be in the drum and then attach the  drum filter  Note that the drum filter incorporates a non return valve to prevent back flow into  the chemical drum     Before placing the tubing into the drum  measure the tubing against the outside of each drum  and wrap several turns of PVC tape around the tubing above the drum lid so that the drum filter  will be 10 15mm above the bottom of the drum  Lower the drum filter and sinker into the drum  and screw on the lid     THE CHEMFLOPLUS FRONT PANEL    ChemfloPlus Display  The ChemfloPlus uses a four line LCD display to provide the user with information   LCD Display  Line 1   15 27 NORMAL Auto  Line 2   AutoON   AutoOFF 21 00  Line 3   ORP 670mMV SET 650mV  Line 4 pH 7 5 SET 7 6    READ OPERATION MANUAL FOR DETAILED INSTRUCTIONS       Waterco ChemfloPlus   pg 07    Line 1 shows the current time and the mode of operation   In the example above  line 1  tells you that the time is 3 27pm and the ChemfloPlus  is operating in    Normal Automatic mode     Note that the ChemfloPlus displays the time using a 24 hour clock     Line 2 shows timer information   In the example above  line 2 tells you that the    unit is turned ON and will turn OFF  automatically at 21 00  Qpm        Line 3 displays ORP  Chlorine  information   In the example above  li
19. ry alkaline  demanding more acid than can be  supplied by the ChemfloPlus  Faulty peristaltic pump  Filter requires backwashing  Multi electrode  probe  may require cleaning  See page 24 for details   Injector nozzle is blocked  Venturi system  if fitted  is blocked    If each of these factors is addressed  the ChemfloPlus will dose the pool with acid until the set  level is achieved     at which point the status indicator will revert to green and the warning will no  longer be shown on the LCD     MAINTENANCE    Like all equipment the ChemfloPlus will look better and last longer if it is maintained and  operated in accordance with these instructions     The ChemfloPlus Power Supply    The Power Supply has been design for operation in full sun and weather  However  it will benefit  from being under cover  There is little maintenance required however     some Do   s and Don   ts        Don   t    e Install it in a small sealed enclosure  so it does not overheat    Install it in a very hot unventilated shed  so it does not overheat    Allow insects to nest in the unit  because they will prevent it from functioning    Install chemical drums under or close to the unit  to prevent corrosion    Forget about the unit once installed     it should be checked regularly to ensure that it is  working for you    Do    e Install it as per the instructions   e Check it regularly   e Make sure the pool balance is checked regularly    ee    Waterco ChemfloPlus   pg 17    Cleaning the Multi el
20. urned ON within 1 minute   The ChemfloPlus will keep all its settings and will not need to be re programmed     The ChemfloPlus is ideal for use in systems where repeated power cuts occur  such as off peak  power circuits and Queensland   s Tarriff33 system     WARRANTY    Controller  Power Pack     24 months       Peristaltic Pumps 24 months  pPH ORP Sensor 18 months    Please refer to Waterco   s Warranty booklet for terms and conditions    
21. utton to increase the adjusted  value to the required level  Press ENT to confirm the adjustment and after a few seconds the  ChemfloPlus will revert to normal operation and the home screen will display the new pH value     Adjust pH System ON or OFF    To disable the pH System  or re enable it if it has been disabled  you need to access the pH  menu and work your way through the MANUAL FEED  ADJUST SET POINT and CALIBRATE  PROBE questions     pressing the N DOWN button in response to each question     The LCD will then read    ADJUST pH CONTROL TURN OFF  Y N     if the system is ON  or  ADJUST pH CONTROL TURN ON  Y N     if the system is OFF   If you press Y UP  the system  will turn on  or off depending on its current status   If you answer N DOWN to either question   the LCD will return to the home screen     Note  Turning off the supply of acid is not normally necessary and could lead to unbalanced pool  water that is unsafe to swim in  Waterco recommends that you seek advice from a qualified  professional prior to disabling the pH system     CHEMFLOPLUS STATUS INDICATORS  WARNINGS  AND SAFETY FEATURES    Normal Operation     Green Status Indicators    When the ChemfloPlus is operating normally and ORP and pH readings are within the correct  range  a green status indicator will be illuminated and the LCD will indicate the readings     Note  it is the pool owner   s responsibility to monitor the pool and periodically confirm the  ChemfloPlus   s readings with a good qualit
22. within a certain range  This is usually between 6 8   fibreglass liner pools  or 7 2  concrete plaster  and 7 8     Adjust pH down with acid   powder  liquid sulphuric or liquid hydrochloric  Be very careful with  acid as it can be harmful and corrosive     Total Alkalinity  TA     Total alkalinity is also known as carbonate hardness or TA for short  The recommended level is  between 80 and 120ppm     TA is related to pH in that it stops the pH from varying quickly with small additions of acidic or  alkaline chemicals  When the TA is low it is almost impossible to control the pH     To raise the TA  buffer  sodium bicarbonate  is added  This must be done slowly as buffer will  also cause the pH to rise  As an approximate rule every increase of 20ppm of TA will also cause  a 0 1 rise in pH  Once buffer is added it should be left to mix in the pool for a few hours before  reducing the pH     Phosphates and Nitrates    Phosphate and ammonia nitrogen will make your garden green     and they will do the same  thing to your pool  Check for phosphates and add phosphate remover if necessary  Don   t let  fertiliser get into your pool  Phosphates are also in some cleaning products     check the label if  using around your pool     When Controlling a Salt Water Chlorinator    Follow the directions for the initial balance for your SWC unit     the difference is likely to only be  the addition of salt or minerals  Note that the ChemfloPlus unit will turn the power to the SWC  unit on and
23. y test kit  Remember that the ChemfloPlus is  only able to balance pH and Chlorine levels   but you need to ensure other factors such  as Stabiliser levels and total alkalinity are within the correct range  see page 6 for details      Low Chlorine    If the ORP falls significantly below the set point  this indicates that the chlorine levels in the pool  have fallen and dangerous pathogens in the water are not being destroyed rapidly     The ChemfloPlus will warn of low chlorine with a red status indicator and the word    low    will be  displayed on the ORP line  line 3  of the LCD     Possible causes include     An empty chlorine drum   Faulty peristaltic pump   Low levels of stabiliser   High pH   Filter requires backwashing   The multi electrode  probe  may require cleaning  see page 17 for details     If each of these factors is addressed  the ChemfloPlus will dose the pool with chlorine until the  set level is achieved     at which point the status indicator will revert to green and the warning  will no longer be displayed on the LCD     ee    Waterco ChemfloPlus   pg 15    High Chlorine    If the ORP rises significantly above the set point  a red status indicator will be illuminated and  the word    High    will appear on the ORP line  line 3  of the LCD     Possible causes include     Manual overdosing  Superchlorination    Faulty peristaltic pump   The multi electrode  probe  may require cleaning  see page 24 for details   Low pH  too much pool acid    High Total Diss
24. your ChemfloPlus and turned it on  you will need to set the correct time  on the ChemfloPlus   s 24 hour clock     First  access the Menu System by pressing the ENT button     The LCD will display the word TIMER MENU  Select this by pressing the ENT button once  more     Line2 on the LCD will now read SET TIME HOURS  Press ENT to select this option and then  use the Y UP and N DOWN buttons  to adjust the hours on the LCD  Confirm the correct hours  value by pressing ENT again     The LCD will now show SET TIME MINUTES  Adjust the minutes using the Y UP and N DOWN  buttons  When complete  press ENT to return to normal operation     ADJUST CYCLES Sub Menu    Your ChemfloPlus has two filter cycles pre programmed as factory defaults as follows     Filter Cycle 1  ON at 6 00  6am   Filter Cycle 2  ON at 18 00  6pm     OFF at 08 00  8am   OFF at 20 00  8pm     You can change the start and finish times of each filter cycle to meet your sanitiser requirements  and to suit your lifestyle     To adjust filter cycle start and finish times  press ENT to access the ChemfloPlus Menu system   Press ENT again to select the TIMER menu and then scroll down using the N DOWN button  until ADJUST CYCLES is displayed on the LCD     Select this option by pressing ENT and the LCD will show the start  ON  time of the filter cycle  being adjusted  Use the Y UP and N DOWN buttons to adjust the start time  Press ENT to  confirm your selection and then the LCD will show the end OFF  time for that filter 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
sasha mi - Jacuzzi  「PV-Green」マークの使用ガイドライン (PDF : 676KB)  Hotpoint Cooktop CG 10455 GF S User's Manual  Télécharger l`agenda  MAN0410-1.1 Morphologi User Manual.book  2. Annexure-B - Specifications  renseignements destinés aux patients apo-terbinafine  SR-585A,B,M 3款说明书-2  要求水準書  ガラス製なべぶたの破損事故    Copyright © All rights reserved. 