1. Flashes when activation of the fans is temporarily delayed DEFROST ON when the defrost is activated Flashes when 7 4 the activation of the defrost is temporarily delayed due to procedures in progress 8 aux AUX n a 9 A ALARM Flashes in the event of alarms 10 CLOCK na 11 LIGHT ON when the cabinet lighting is activated 12 A SERVICE Flashes in the event of malfunctions 13 DISPLAY Shows the cabinet temperature 14 HACCP HACCP n a 15 CONTINUOUS CYCLE n a Operation 11 User Manual SKOPE Food Display Cabinet Integral Temperature The chiller temperature setpoint is factory set at 1 0 C If necessary the Setpoint standard setting can be adjusted between 1 0 C and 5 C SKOPE do not recommend that the setpoint be changed unless it is absolutely necessary and then only by small increments at a time To view and adjust the temperature setpoint 1 To view the setpoint press and hold the see key for 2 seconds until the setpoint value flashes 2 To adjust the setpoint press either the A or keys to display the required setpoint value 3 Press the see key again to memorise the new setpoint value If this is not done within 60 seconds changes will be lost and you will need to repeat the above procedure 12 Operation User Manual Controller Operation Alarms SKOPE Food Display Cabinet Integral Alarm a i Code Display Icon Description
2. SKOPE Authorised Service Agent Failed fluorescent tube Check fluorescent tubes see page 17 Lights are manually turned off Switch the lights on see page 10 Controller alarm Determine cause and eliminate see pages 12 13 3 Power Unit operating too hot Clean condenser Ensure the chiller consumption is is installed with good ventilation higher than around the refrigeration unit expected Cabinet doors are opened Keep doors open for minimum time excessively Product is too Restricted cabinet airflow warm and spoiling Temperature setpoint is too warm Ensure product is not blocking cabinet airflow slots Adjust setpoint see page 12 Warm cabinet Blocked condenser temperatures Poor refrigeration unit ventilation and or compressor operating for long periods more than 1 hour Clean condenser see page 16 Ensure the cabinet is installed with good ventilation round the refrigeration unit Servicing User Manual
3. To replace the ceiling fluorescent tube 1 Disconnect the cabinet from the mains power supply 2 Remove the light diffuser by compressing one end of the diffuser until it disengages from the housing see below 3 The fluorescent tube can now be removed Revolve the tube until the pin position allows withdrawal 4 When refitting the diffuser engage the back section into the housing and then compress and snap the front section of diffuser back into place working along the full length of the light Fluorescent Tube Light Diffuser Shelf Light To replace a shelf light 1 Remove both sliding rear doors by lifting each door up and pulling out at the bottom Remove the wire shelves see page 20 2 Lift the light assembly panel up off both shelf end supports and remove from the cabinet The power supply cable will remain attached Continued over page Servicing 17 User Manual SKOPE Food Display Cabinet Integral 18 3 Remove the light diffuser by compressing one end of the diffuser until it disengages from the housing The fluorescent tube can now be removed Revolve the tube until the pin position allows withdrawal Troubleshooting Complaint Possible Cause Repair 1 Cabinet not Loss of power supply Check mains power supply operating and no controller display 2 Cabinet lights not Blown cabinet fuse Requires technical repair by a operating
4. eo eels 5 Positioning the Cabinet 0 0 0 0 0 cee ee 6 Cabinet Location 000 000 eee eee 6 Installation Guidelines 0000 20 e eee 6 Power Cord oe cei bea ee ee dad dee ee aed ew ta de ae Cees 6 Ventilation sas ccn dint aaa a ida dc 7 SA A RED bee ae ao waa ale Bete 8 Adjusting the Shelves oooocccccccc ee 8 Locking Castors esorare nisser iarere siahai nee 9 Loading Product 2 4 0deedadie sl eee er E aa Dac 9 Operation Start UPa aaa a aa ae en a aa e a a i paat 10 Refrigeration Unit cee re RER NE ec eee 10 Cabinet Lighting soseri SAR SE eee beens 10 Electronic Controller 20000 cece eee eae 10 Electronic Controller 22 sneen ennen eee 11 Faceplate 0 000 cece eee 11 Temperature Setpoint 0 002s 12 Controller Alarms 2 00 000 c eee eee eee 13 Servicing Isolating Electrics 0 RR ER MERE eee 14 A theta void heeled ted E id ta ed 14 Cabinet iia a pate Le wed PEG Oye aS 14 Condenser OO 16 LIRING vesical 17 Gelling Light press dt S N 17 Shelf LIONE vita ad ta n 17 Troubleshooting 000 in EE te eee 18 SKOPE Food Display Cabinet Integral User Manual SKOPE Food Display Cabinet Integral 1 Installation Safety First When using any electrical appliance safety precautions should always be observed Read these instructions carefully and retain for future reference This appliance i
5. power cord fitted with a 3 pin plug which exits out the rear of the cabinet The power cord should be retrieved before the cabinet is positioned as walls and partitions may make access difficult Installation User Manual SKOPE Food Display Cabinet Integral Ventilation Adequate ventilation is essential For efficient operation of the Food Display Cabinet it is essential that adequate ventilation be provided around the refrigeration unit a Do NOT cover the rear ventilation panel or block the entry or exhaust of airflow by placing objects up against the refrigeration unit a Do NOT block the air vent slots around the bottom of the glass These air vents are used to keep the glass clear of condensation Important For efficient operation of the Food Display Cabinet it is essential that adequate ventilation be provided around the refrigeration unit Air Vents Air Vents Refrigeration Unit Rear Ventilation Panel Installation User Manual SKOPE Food Display Cabinet Integral Adjusting the Shelves Shelving The Food Display Cabinet is supplied with pre installed shelving and lighting The shelving consists of two levels of angled adjustable shelves and one bottom level of stainless steel trays The adjustable shelves can be positioned either horizontal or angled down 5 The shelving is designed to be easily removed from the cabinet for ease of cleaning Before initial operation the plastic ties th
6. Initial Action Fris Product HIGH 1 Check the cabinet product Flashing temperature alarm loading to ensure ventilation slots are not blocked and that product does not overhang the shelves 2 Ensure the cabinet is installed with good refrigeration unit ventilation Flashing Product LOW 3 Check and clean the temperature alarm condenser coil see page 16 4 To reset the alarm unplug cabinet from the power supply for 1 minute then reconnect to power supply raam persists Refrigeration i contact i system high 1 Clean the condenser coil see SKOPE T Y N lashing temperature pre page 16 warning 2 Check refrigeration ventilation Ensure there is adequate ventilation around the refrigeration unit see page 7 Refrigeration 3 Ensure the cabinet is installed moo Rg system high in a suitable environment la ME Pleming temperature see page 6 shutdown 4 To reset the alarm unplug cabinet from the power supply for 1 minute then reconnect to power supply k i i A Flashing Ambient probe fault ae A Evaporator probe lt i Flashing fault Tr Condenser probe I C Flashing fault To reset the alarm unplug if alarm Defrost over time Ta iom fe parar Suen y persists None limit for 1 minute then reconnect to st power supply SKOPE HA O mm re TE Flashing Controller E prom Ec Y N error Z T Flashing Controller E prom A I error None Start defrost request None None None End defrost request User M
7. Remove the shelf brackets by lifting up at the front and pulling out from the cabinet The floor panels can be removed from the cabinet by lifting each panel up The floor of the cabinet can now be accessed for cleaning Warning Be careful not to touch the exposed evaporator coil fins as they are very sharp and damage easily Both door guide bottom runners can be lifted out for cleaning The evaporator drain should be regularly checked and cleaned to prevent blockage To access the drain hole remove the rear floor panel from inside the cabinet see photo above If using water to clear the drain care should be taken not to overflow the condensate tray see below The evaporator drain tube should also be checked for blockage To access the drain tube remove the ventilation panel from the rear of the cabinet by undoing the two bottom screws and unhooking from the cabinet To clear the drain tube pull the drain tube out from the cabinet and drain the water into a bucket Drain Tube User Manual 15 SKOPE Food Display Cabinet Integral Condenser The condenser coil MUST be kept clean for reliable operation and to Coil minimise power consumption a blocked condenser can double power consumption To ensure trouble free performance the condenser coil should be brushed clean once a month If the electronic controller display flashes cht the condenser coil must be cleaned immedia
8. User Manual MAN20560 Rev 2 0 Aug 2010 FDM Series SKOPE Food Display Cabinet Integral models FDM900i 1200i 1500i Model FDM1200i SKOPE Refrigeration Integral models FDM900i 1200i 1500i SKOPE Food Display Cabinet User Manual MAN20560 Rev 2 0 Aug 2010 O 2008 SKOPE Industries Limited All rights reserved SKOPE Industries Limited reserve the right to alter specifications without notice SICODPIE is a registered trademark of SKOPE Industries Limited SKOPE INDUSTRIES LIMITED Head Office PO Box 1091 Christchurch New Zealand Freephone 0800 947 5673 Fax 03 983 3896 E mail enquiry skope co nz Website www skope co nz Trademark Infringement The SKOPE trademark on this product is infringed if the owner for the time being does any of the following e Applies the trade mark to the product after their state condition get up or packaging has been altered in any manner e Alters removes including part removal or obliterates including part obliteration the trade mark on the product e Applies any other trade mark to the product Adds to the product any written material that is likely to damage the reputation of the trade mark Notice of the above contractual obligations passes to e Successors or assignees of the buyer Future owners of the product CONTENTS Installation Safety First cova eda aa dag dae waa o ED 4 AA 5 Operation 000 0 eee 5 Helptul TIPS sti cease te pene kee Aa
9. anual 13 SKOPE Food Display Cabinet Integral 3 Servicing Cabinet 14 Isolating Electrics The chiller must be isolated from the mains power supply before attempting any cleaning or maintenance To isolate the chiller unplug the power cord plug from the power supply socket Cleaning When necessary the interior and exterior of the cabinet can be wiped with a damp cloth The sliding doors wire shelves shelf support panels shelf lighting and floor panels can all be removed from the cabinet for ease of cleaning Caution Isolate the cabinet from the mains power supply before attempting any cleaning or maintenance 1 Isolate the chiller from the mains power supply see above 2 The sliding doors can be removed from the cabinet by lifting each door up and pulling out at the bottom To refit the doors lift each door up into the top track and place onto the bottom track 3 The wire shelves can be lifted out of the cabinet for cleaning When refitting the wire shelves ensure the bottom rail on each wire shelf sits against the rear support This prevents the shelves sliding backwards 4 The shelf rear support panels and shelf lighting can be removed from the cabinet by lifting up off the shelf brackets The power supply cable will remain attached to the lighting panels Continued over page Servicing User Manual Servicing SKOPE Food Display Cabinet Integral
10. astor wheel Castor Locking Lever in locked position Loading Product The Food Display Cabinet should be left running for 30 minutes before loading with product When loading the cabinet shelves with product o Allow air space around all the product to ensure even cooling and efficient operation of the chiller o Leave an airspace of at least 75mm above product loaded on the top shelf o Do not allow products to overhang the rear of the shelves as this could prevent the sliding doors from shutting properly Do not exceed a maximum loading of 20kg per shelf Remove some product if the shelves are flexing or bending Installation 9 User Manual SKOPE Food Display Cabinet Integral 2 Operation Refrigeration Unit Cabinet Lighting Electronic Controller 10 Start Up Plug the cabinet into the power supply and check operation of the refrigeration unit cabinet lighting and electronic controller The compressor and condenser fans should all operate within two minutes from the time the cabinet is plugged in This may be verified by listening for compressor switch on and checking for air movement out of the air vent slots around the bottom of the glass The compressor and condenser fans should switch off and on depending on the cabinet temperature The Unit switch on the right hand side of the controller turns the refrigeration unit off O and on I The refrigeration unit should not be turned off
11. at hold the shelving and lighting must be removed allowing the shelf angles to be adjusted 1 Remove both sliding rear doors by lifting each door up and pulling out at the bottom 2 Cut the plastic ties that hold the shelves in position during transit and remove the shelves from the cabinet When refitting the wire shelves ensure the bottom rail on each shelf sits against the rear support This prevents the shelves sliding backwards 3 Remove the shelf rear support panels and shelf lighting panels by lifting up off the shelf brackets The lighting panels have power cables connected to the cabinet limiting how far they can be pulled out from the cabinet 4 Position the shelf brackets at the required angle The support brackets can be positioned either horizontal or angled down 5 5 Refit the shelf support panels light panels and wire shelves Refit the sliding doors by lifting each door up into the top track and placing onto the bottom track Installation User Manual SKOPE Food Display Cabinet Integral Locking Castors After positioning the cabinet both rear castors wheels should be locked to prevent the cabinet from moving To access the rear castors remove the ventilation panel from the rear of the cabinet by undoing the two bottom screws Push the locking lever firmly down on both rear castors see below Ensure the ventilation panel is refitted after locking the castors C
12. ation SKOPE Food Display Cabinet Integral Introduction Thank you for choosing a SKOPE Food Display Cabinet To ensure you get the most out of your product please read these instructions prior to installation and plugging in of the cabinet Although this chiller is very energy efficient further reduction in power consumption can be achieved by turning off the lighting and refrigeration unit when not required Saving Power Options Level Action Requires no adjustment d Simply plug in the cabinet for significant power savings 2 Turn the cabinet interior lights off 3 Turn the refrigeration unit off non perishable product only 4 Turn the cabinet interior lights and refrigeration unit off The cabinet interior lights and refrigeration unit can each be turned off separately using the switches beside the electronic controller see page 10 Below are some helpful tips on how to reduce power consumption and service costs 1 Turn the cabinet interior lights off when lighting is not required 2 Turn the refrigeration unit off when the cabinet is being used only for display purposes not being used for perishable product 3 Ensure good ventilation of the refrigeration unit by installing in an area away from heated appliances ovens and away from direct sunlight see pages 6 7 4 Ensure the sliding doors are opened for the minimum of time Encourage staff and customers to make product choice
13. prior to opening the doors 5 Ensure the condenser is kept clean Check the condenser is clean every month See page 16 for instructions on cleaning the condenser coil User Manual SKOPE Food Display Cabinet Integral Cabinet Location Installation Guidelines Power Cord Positioning the Cabinet When positioning the Food Display Cabinet avoid direct sunlight and warm draughts etc The cabinet should not be situated where it is affected by hot air from adjacent equipment as this will compromise the airflow and performance The cabinet must be positioned on a level surface for the sliding doors to shut and seal correctly and to prevent the condensate tray from overflowing The Climatic Class for the Food Display Cabinet is 4 This means the Food Display Cabinet is suitable to operate in an ambient temperature at place of installation of 30 C at 55 humidity The cabinet is designed to operate in a maximum ambient of 32 C at 70 humidity but will generally use less power when installed in a cooler location When installing the Food Display Cabinet o Avoid direct sunlight and warm draughts etc o Ensure the cabinet is positioned on a level surface so the sliding doors shut and seal correctly and to prevent the condensate tray from overflowing o Do not overload the power supply see rating label inside the cabinet for power supply and current draw The Food Display Cabinet is supplied with a 1 8m flexible
14. s not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with this appliance Do NOT use this appliance for other than its intended use Do NOT cover the grilles or block the entry or exhaust of airflow by placing objects up against the refrigeration unit Do NOT probe any opening Do NOT overload the power supply Only use this appliance with voltage specified on the rating label Ensure adequate ventilation of the SKOPE refrigeration unit Regulations require that all electrical work be carried out by authorised persons For your own safety and that of others ensure this is done If the supply cord is damaged it must be replaced by a SKOPE authorised service agent or similarly qualified person in order to avoid a hazard If the refrigeration unit is required to be installed or removed from the cabinet ensure all necessary safety precautions are observed If this appliance needs to be disposed of contact SKOPE Industries for information regarding disposal of the appliance Caution Always isolate the cabinet from the power supply before attempting any maintenance Installation User Manual Operation Helpful Tips Install
15. tely Over time dust may accumulate within the condenser that cannot be removed with a brush If this occurs contact SKOPE to arrange for a SKOPE Authorised Service Agent to clean the condenser with compressed air Important If the electronic controller flashes cht the condenser coil must be cleaned immediately The condenser coil is situated inside the refrigeration unit compartment at the bottom of the cabinet To access the condenser coil 1 Disconnect the cabinet from the mains power supply 2 Remove the ventilation panel from the rear of the cabinet by undoing the two bottom screws 3 Be careful when cleaning the coil fins as they are very sharp 4 Ensure the ventilation panel is refitted Caution Disconnect the cabinet from the mains power supply before cleaning the condenser coil 16 Servicing User Manual SKOPE Food Display Cabinet Integral Lighting The Food Display Cabinet is fitted with three fluorescent tube interior lights One light is located in the ceiling of the cabinet The other lights are located underneath the front of each shelf See the chart below for fluorescent tube specifications Model Fluorescent Tube Specifications FDM900i 14 Watt T5 fluorescent tube 016mm x 550mm Warm White 830 FDM1200i 21 Watt T5 fluorescent tube 016mm x 850mm Warm White 830 FDM1500i 28 Watt T5 fluorescent tube 016mm x 1150mm Warm White 830 Ceiling Light
16. unless the cabinet is being used for display purposes only no perishable product Defrost Current N A Charge 950g Insul Blowing Agent Cyclo iso Pentane A sg Interior Refrigeration Lights Unit Sim i ms Ea a Bla sa A Lights Switch Unit Switch All three interior lights will operate continuously unless they are manually switched off using the Lights switch on the left hand side of the controller The cabinet fluorescent lights will require a period of time to stabilise following initial start up At initial start up the electronic controller will display the current cabinet temperature see pages 11 12 for controller display Operation User Manual SKOPE Food Display Cabinet Integral Electronic Controller Faceplate Keypad Item Key Function Prg mute To initiate programme sets press for 5 seconds 1 Mutes the audible alarm buzzer and deactivates the alarm relay 2 UP aux To scroll settings UP in programme mode Set If pressed for more than 2 seconds displays and or 3 3 enables changing the temperature setpoint see page 12 4 y DOWN def To scroll settings DOWN in programme mode Icons Item Icon Function COMPRESSOR ON when the compressor and condenser 5 S fan starts Flashes when activation of the compressor is temporarily delayed 6 rA FAN ON when the internal cabinet fans are activated