Home

Instructions for use Possible malfunctions / troubleshooting

image

Contents

1. l 3 Minimising screw is screwed in incorrectly l Excessive soot 1 Poor fresh air ventilation to the burning chamber build up 2 Not enough draught in the exhaust channel chimney can be caused by bad weather conditions be adjusted If it does not seem possible to remedy the malfunction based on the above trouble shooting table we suggest you contact your vendor or the manufacturer The control unit gas valve supplied with your Milafire log fire model has been carefully tested by the manufacturer and has been adjusted to the recommended Nominal Load amount for the gas burner supplied We recommend you do not adjust those settings under any circumstances not even when troubleshooting some malfunction as per the above table does not remedy the issue Any adjustments to the control unit could result in your warranty being voided Milan Industries b v e e Manufacturer of Milafire gas log fires il afi re Internet www milafire nl
2. Instructions for use Lighting procedure Turn the high low knob 2 completely to the left See fig 1 Prior to igniting the pilot flame the pilot gas line should be purged as follows Turn ignition knob 1 to position 3 and keep fully pressed in for at least 5 seconds Subsequently turn the knob still pressed in forcefully to the left Repeat until the pilot flame has been lit Keep the knob pressed in for a few seconds more then turn to the left to ignite the burner bed High low adjustment The left knob 2 is the adjustment knob herewith the flame display can be adjusted from high to low In case the log fire has not been used for a longer period of time it might be possible that the pilot line contains air If so the pilot line has to be purged Repeat the lighting procedure as described above Shut off procedure Extinguish the fire by turning the knob 1 clockwise to position 3 The pilot flame will continue to burn To extinguish the pilot flame as well turn the knob completely to the right to position 4 Safety precautions Make sure that no flammable materials such as nylon clothing are brought into the immediate vicinity of the fire Children should keep away from the direct vicinity of the open fire Pilot flame burner To facilitate proper ignition of the burner bed it is important to keep the area near the pilot flame burner free from any material See fig 3 Fig 2 Fig 3 Milafire P
3. ossible malfunctions troubleshooting The ignition The piezo control cable C is damaged Requires replacing does not work See fig 2 Electrical short circuit between the piezo cable C and the conduit Protect the piezo cable or move reposition it See fig 2 3 The distance between the ignition electrode A and the thermocouple B is too small or too big optimum distance is 3mm See fig 2 4 Check if the piezo cable C is correctly installed to the sparker and or the ignitor See fig 2 Poor flame 1 The gas pipe is too long and or too small diameter display 2 The gas pressure is too low Gas pressure should always be at least 25mbar 3 Blockage in the gas pipe The fire 1 A room draught can extinguish the pilot burner flame This can extinguishes be prevented by surrounding the pilot burner with coal e The pilot burner set has been incorrectly installed See installation instructions See fig 2 3 Pilot burner is defective The thermocouple B is burnt out Flame divider D has been damaged which obstructs the pilot flame to burn properly replace pilot flame burner Solenoid valve if present is defective and needs replacing Flames cannot The control unit has been incorrectly installed check gas connection to the control unit and from the control unit to the burner 2 Pollution in the gas pipe or in the injector check pipes and injector

Download Pdf Manuals

image

Related Search

Related Contents

Kodak DC210+ User's Manual  注意喚起  1. SevenMulti - METTLER TOLEDO  CT1000GD Troubleshooting Flow Chart  KitchenAid WF-LC400V Refrigerator User Manual  Fujitsu LIFEBOOK A555  BACHELOR THESIS Michal Kebrt Word-to  StarTech.com CABTPAD touch pad  Harman Kardon CD401 User's Manual  La Vendée, capitale du cyclisme en 2010  

Copyright © All rights reserved.
Failed to retrieve file