1. 0O M 0 Non addressable mode The number of used DMX channels is same as the defined Addressable mode The number of used DMX channels used for control OUT is as follows DATA TYPE number x number of ADDRESSABLE LIGHTS Example DATA TYPE 2 3 bytes Number of ADDRESSABLE LIGHTS 5 DMX channels used 3x5 15 Set default Sets the parameters to their default values Parameter Value Speed mode 0 Number 0 Data type 2 Programming the light address The set up procedure Connect the light to the DMX512 interface LXU01 Connect the light to the power supply Switch on the light the light must light Switch off the light the light must NOT light Disconnect the light from power supply Connect the DMX interface LXU03 to the power supply Set the switch 12 to ON position Set the programming mode with the switches 5 8 to ON position Set the light new address to 1 15 with the switches 1 4 10 Connect the light to the power supply and IMMEDIATELY continue with step 11 11 Set the switch 11 to ON position 12 Wait for 5 seconds 13 Set the switch 11 to OFF position 14 Set the switch 12 to OFF position APPEARANCE DADAS 80 DMX SETTINGS ON 123456 7 8 9 1011 12 TECHNICAL SPECIFICATIONS Input voltage 12 24 Vdc Consumption max 50 mAdc Operating temperature 10 C 50C Casing ABS Protection IP 65 Dimension
2. 7 Setthe switch 12 to OFF position DIP switch DIP switch SET UP 5 6 7 8 1 2 3 4 OFF OFF OFF OFF 0 2 Speed mode ON SORE ORE EF 0 15 Number of addressable lights OFF ON OFF OFF 0 3 Data type OFF ON ON ON not used Set default ON ON ON ON 1 15 Programming the light address 6 Speed mode Defines the ASTEL protocol communication baud rate Value FUNCTION 0 LOW speed 1200 bps 1 MID speed 2400 bps 2 HIGH speed 4800 bps Number of addressable lights This defines how the OUT is acting There are two basic modes non addressable all the lights on the control OUT light in the same way addressable there can be up to 15 address and each light connected to the OUT can have the address from 1 to 15 each light with different address can light different There can be more than one light with the same address the number of the lights with the same address is not limited To set up non addressable mode set the switches 1 4 to OFF To set up addressable mode set the switches 1 4 to the number of the lights with different addresses on the control OUT Please pay attention the higher number results in lower refresh rate Data type This defines the number of data bytes used for light the number of DMX channels for each light on the control OUT Value FUNCTION 1 byte not used 2 bytes not used 3 bytes RGB lights 4 bytes not used
3. immediately and refer servicing to qualified service personnel if the DMX512 Interface LXUO1 does not operate normally following the operating instructions CONTROLS AND CONNECTORS DMX512 Interface LXU01 1 DC IN Terminal block connector to connect 12 24Vdc power supply 2 OUT Control output to connect the Control P and GND Control wires of multi color RGB lights Meteor series or PWM dimmer LDU13 3 CONTROL The 3 pole terminal block connector to connect DMX512 line 4 DMX SETTINGS DIP switch to set the DMX512 and METEOR protocol commmunication parameters INSTALLATION The DMX512 Interface LXU01 kit consists of the following components DMX512 Interface LXU01 3 x terminal block connectors Operating Instructions with Declaration of Conformity and Warranty conditions The LXU01 has to be installed on a suitable location Avoid the installation in extremely hot places and near appliances generating strong magnetic fields The installation has to be realized by a qualified personnel Note The main DC power supply has to be switched off before installation D DMX512 LINE ASTEL PROTOCOL iA OUTPUT UOl1 DMx512 INTERFACE YV Power supply connection The power supply has to be connected through the switch not included and protected by a fuse not included to the DC IN terminal block connector with correct polarity The power supply voltage has to be from 10 30Vdc ASTEL protocol o
4. NS LE D technology ART A9915501 DMX512 INTERFACE LXU01 Operating Instructions Design and specifications subject to change without notice Pes CONTENTS o AE E AT E E E tet dew he 3 FORMES AA DE AA A aa AAA A ta 3 Precautions a eh hese eee a A aaa eee thle AA A EESE 3 Controls and CONNECT aieeaa e ati 4 DMX512 Interface LXUD Esc is wid MIS EAM AOR a A E eae EA he sal tat TENER LIRA DAL id 5 SALUDA E AA A A ee RTS Pe EA EA 6 PADD GAP ANIC O AA wernt a 8 Technical SMSC MGALOMS A 8 Warranty a AS A AA O E a O a 9 Declara ONO CONTO MIN tar kets e AE A EAT EA AENA AA ATA ATA RS 10 PREFACE The LXU01 is DMX512 to METEOR protocol converter with 1 output to control a groups of RGB multi color lights of METEOR series with built in METEOR protocol The DMX512 control of single color lights METEOR series is enabled by using the PWM dimmer LDU13 with built in METEOR protocol FEATURES 1 Control Output DIP switch Programmable Multi Speed Mode Wide Range Power Supply Low Power Consumption Polarity Protection Transient Protection Short Circuit Output Protection Simple Installation PRECAUTIONS The DMX512 Interface LXU01 has to be installed and used in accordance with the instructions of this manual only The power supply has to be disconnected before installation Avoid installing the DMX512 Interface LXU01 in extremely hot places and near appliances generating strong magnetic fields Do turn power off
5. s max 67x80x21mm Weight 0 1 kg Design and specifications subject to change without notice 8
6. utput connection The 2 control wires of multi color RGB lights Meteor series or PWM dimmer LDU13 for single color lights control have to be connected to the OUT terminal block connectors DMX512 line connection The DMX512 control wires have to be connected to the DMX IN terminal block connector SET UP The DMX512 Interface LXUO1 set up is enabled by adjusting the DIP switch DIP switch VALUE 1 2 3 4 OFF OFF OFF OFF 0 ON OFF OFF OFF 1 OFF ON ON ON 14 ON ON ON ON 15 DIP switch VALUE 1 2 3 4 5 6 7 8 9 OFF OFF OFF OFF OFF OFF OFF OFF OFF 0 ON OFF OFF OFF OFF OFF OFF OFF OFF 1 ON ON OFF OFF ON OFF ON ON OFF 211 OFF ON ON ON ON ON ON ON ON 510 ON ON ON ON ON ON ON ON ON 511 In normal operation the switches 1 9 define the DMX address Note The switch 12 must be in OFF position for normal operation The DIP switch is used to set up the mode of operation and programming DIP switch FUNCTION switches 1 4 Parameter 5 8 Mode of operation 9 10 Not used 11 Programming trigger 12 Programming mode The set up procedure 1 Set the switch 12 to ON position 2 Setthe programming mode with the switches 5 8 as described below 3 Setthe parameter value as described below 4 Setthe switch 11 to ON position 5 Wait for 5 seconds 6 Setthe switch 11 to OFF position