Home

Installation and User Manual version: 2.0, revision: 38

image

Contents

1. 3e e e e ede de dede de de eode de TE de e de eode ded de de e de dede d d dee de dede d e de ded dw Valori aggiornati al Ciacenza calcolata 2 Giacenza da sonda di livello Pompa collegata alla cisterna isterna collegata alla pompa 02 Valori aggiornati al Giacenza calcolata Giacenza da sonda di livello Pompa collegata alla cisterna 16 02 2009 11 33 01976 000000 dl 3e de e he ede de dede TTT TE TE dee de LE dde TE de dede de d dee de O LE d e de dede dw 04 12 2008 11 28 o2000 ogoogo dz Pag 86 Amico Installation and User Manual 4 8 Scheduled Maintenance Scheduled maintenance management allows alarm notifications upon expiry of kilometric maintenance or on established dates to be obtained Manutenzioni Click on the button Manutenzioni Ogni scadenza a giorni x Numero automezzo e descrizione H tutti Chilometri o ore attuali DOCU Nascondi manutenzioni non scadute Nascondi manutenzioni con km errati 7 Solo manutenzioni del mezzo selezionato Anticipa le manutenzioni di km 0000 Anticipa le manutenzioni di giorni 000 Registra la manutenzione Rapporto delle manutenzioni Storico manutenzioni effettuate Cambio conta km o contaore 3 Nuova 4 Modifica Tf Elimina 4 8 1 Connection to vehicle maintenance To set maintenance it is necessary to associate them and customise them for each vehicle Click on the gt Nuova button t
2. This limits the operation of this AmiTag on the pump number indicated 0 indicates that there is no limit on the pump number The pumps are numbered in the Amico equipment under the heading of Pump Numbering 1 2 This limits the operation of this AmiTag on the pumps belonging to the company indicated 0 indicates that there are no limitations on the company number The companies affiliated with the pumps are defined in the Amico equipment under the heading Company Numbering P 1 2 Button to read the AmiTag parameters Button to write changes on the AmiTag Button to write the AmiTag and increase by one the card number and the vehicle number This is used when several AmiTags are to be written in succession Button to reload the parameters of a card that was saved Button to save the parameters of this card so as to be able to recall them Vehicle number is the number with which the vehicle is identified inside of the WinAmiFree software In the vehicle identification list it is the number associated with the description and with the license plate of the vehicle Card number is the number that identifies the AmiTag and is used exclusively for disabling it in case of its being lost Machine code is the number that identifies the Amico control unit or a group of Amico equipment on which the same AmiTag may refuel It identifies the user It must be communicated when requesting new AmiTags management Software Pag 95 Amico Instal
3. 2 4 1 1 1 AmiTag Vehicle and kilometre request from the odometer 32 2 4 1 1 2 AmiTag Vehicle request kilometres and request driver code 32 2 4 1 1 3 AmiTag Vehicle request kilometres and Driver AmiTag 33 2 4 1 1 4 Driver AmiTag and enter the vehicle number to be refuelled 33 2 4 1 1 5 Check and verify the kilometres and any eventual errors 34 2 4 1 2 Download data onto a Personal Computer with WinAmiFree software 35 2 4 1 2 1 Manual data download from Data Download AmiTag 35 2 4 1 2 2 Download data from cable connection iii 36 2 4 1 2 3 Download data from the Internet connection AmicoOnLine 36 2 4 1 3 WinAmiFree software main fUnctions iii 36 3j User Manudl iusssisenuunRFEFExERURS VEENS KE VER ari 41 31 AMICO CONTO BUR MUI PT T tT 42 3 1 1 Turning on and operator panel description mmm mmn 42 3 1 2 Optional requests during refuelling enabling sse 43 3 1 2 1 1 Request secret code PIN code eeeeeeeseeeee nnne 43 23 1 2 1 2 Requestiriver COdB ussibueteonuguustsber tutte maces ea noie 43 3 1 2 1 3 Request job order number cost centre 44 3 1 2 1 4 Request dispenser number ue EE ice oben Mies ieee ceeds ees 44 3 1 2 1 5 Entry of outside refuelling data es vx x ERR REY XE a QU
4. 2 4 1 2 Download data onto a Personal Computer with WinAmiFree software For a detailed description of the data download operations see paragraph 4 5 Download refuelling data To download refuelling data to a PC from the refuellings memorised on the AmiTag Data Download card click on the Download data from the card button The data is read inserted into the PC archive and deleted from the AmiTag card 2 4 1 2 1 Manual data download from Data Download AmiTag To download refuelling data memorised on the Data Download AmiTag onto the PC click on the Download data from card button The data is read and saved to the PC archive and deleted from the AmiTag Installation Manual Pag 35 Amico Installation and User Manual 2 4 1 2 2 Download data from cable connection Click on the Data Acquisition button The PC connects to the Amico control unit and downloads the refuellings in memory The data are saved in the archive and deleted from the Amico memory 2 4 1 2 3 Download data from the Internet connection AmicoOnLine Activate the PC internet connection If it isn t activated click on the AmicoOnLine button and then on the Data Acquisition button The WinAmiFree software downloads the data from the AmicoOnLine server and saves them to the historical archive 2 4 1 3 WinAmiFree software main functions Click on the Latest Data Acquired button to visualise the refuellings carried out Report Window WinAmiFree r 0
5. Amico Installation and User Manual MOTOR OVERLOAD PROTECTION DEVICE OPTION In the event of the powering of a pump motor above 0 5 KW a motor protection overload device must be made available in the case that it has not already been provided for on site the thermal protection device must be chosen as a function of the absorption indicated on the motor plate IMPORTANT In the event that both motor options are put into place the ratings must be identical In other words if the power of the motor relative to pump no 1 is 0 5 KW the same must go for the motor relative to pump no 2 The same goes for motors of a higher rating as well MICRO MODEM REMOTE CONNECTION VIA CABLE OPTION Encased power supply Utilisation inside of buildings Connectible to the office PC via RS232 Serial serial port with DB9connector with DB9connector Frequeny B S Hz OoOo Absorption 100mA Maximum Distance 200 metres Connection with cable suitable for the installation with 6 wires of which 2 x section imm 4 x section 0 5 mm shield PLEASE NOTE Average time for download of 100 refuellings gt about 60 seconds REMOTE CONNECTION VIA GSM GPRS MODEM External electrical power or RJ 45 6 connected internally to AMICO 2005 data power supply Output 5 V DC card Absorption 50mAatrest400 O mA in trasmission Connection GSM GPRS A SIM card with data transmission network contract furnished by
6. Amico does not need a direct connection with a personal computer To transfer data acquired besides with the direct cable the download data AmiTag or the AmicoOnLine form may be used see Command transmission to the AmicoOnLine server via internet on a GPRS network The Amico System works 24 hours a day without any need for maintenance except for the replenishment of the paper in the internal printer if there is one It does not need an operator because it is the driver him or herself who with a simple operation uses it It memorises data having to do with the operation performed date and time of the refuelling identification number of the vehicle and eventually of the driver litres dispensed kilometres driven etc All of the information memorised internally are maintained even in the event of a power failure for a period of at least 5 years In the event of an electrical power failure during refuelling the data is saved automatically Product Description Pag 7 Amico Installation and User Manual 1 1 Use Limitations A The AMICO device may not be installed inside of an area with an explosion hazard A The AMICO device must be installed far from inflammable surfaces or substances The AMICO device must be connected exclusively to systems for which it was Product Description Pag 8 Amico Installation and User Manual 1 2 Amico Versions This document is to be applied to the following versions e Amico 3000 r
7. Storico dati acquisiti dal 01 07 1996 ali0 07 1996 sulla pompaDi Totalizzatore 2766 4504 19740 08 Pag 78 Amico Installation and User Manual 4 6 6 External refuellings External refuellings are those that are carried out on the roadway or at pumps not managed by the Amico system So that the WinAmiFree software is able to correctly calculate the consumption averages it is necessary to have the external refuellings as well They may be entered ion two ways directly by the operator onto Amico at the time of refuelling or else by the WinAmiFree software in the Archive Click on the button Pifernimenti Esterni Inserimento rifornimenti automezzo IS j Autista pon fe Datae Ora sabato 28 febbraio 2009 35306 chilometri 000000 Litri 0000 fo 99 W INSERISC il CANCELLA Enter the Vehicle AmiTag number or select from the list the driver the date and time of the external refuelling and the litres Click the button V INSERISCI Inserimento rifornimenti x Automezzo 0002 ooo2 MULETTION1 r gt Autista n002 oo02 GabettaMassimiiano DataeOra sabato 28 febbraio 2008 10 53 06 chilometri 123456 Litri 0000 00 99 Y mstmisci _ CANCELLA 0002 0002 123456 99 0045 00 10 53 20090228 032 0001 0001 123456 99 0010 00 09 53 20090228 032 WinAmiFree management Software Pag 79 Amico Installation and User Manual Rep
8. AmicoOnLine the refuelling is transmitted to the AmicoOnLine server The transmission is carried out by way of a GPRS call through the telephone service provider chosen On the display the following message will appear If there happened to be some problem with the connection the following message will appear on the display And the refuelling remains memorised in the Amico memory It will be transmitted at the end of the next refuelling The possible error messages are the following e NoSimIns The telephone SIM card has not been inserted or has been inserted incorrectly e PIN Error Remove PIN code from SIM e RifNoIns Wait for data transmission in the AOL module buffer e NoGprs The GPRS signal is not present This should be only a momentary problem of the telephone service provider or the SIM card is not enabled for GPRS e NoSignal There is not sufficient signal from the antenna Connect an external antenna or shift the position of the present one e NORISP The AOL module does not respond Wait 5 minutes and retry In the event of negative response check and verify the connection When a refuelling cannot be transmitted it remains in the Amico memory which at the end of the next refuelling will attempt to retransmit it If for a long period it were not possible to transmit the refuellings once the connection has been restored Amico will transmit only 10 refuellings at a time at the end of each new refuelling so as
9. plant system For a multiple plant system a group of Amico devices belonging to the same user is meant Even if the data is managed by one single software program each dispenser unit is assigned a definite number that allows the dispenser unit on which refuelling is performed to be clearly identified Optionally each dispenser unit may be attributed to a certain type of product dispensed and its inclusion in a specific group In this way refuelling may be limited for specific TAG groups see AmiDesktop Programming of the AmiTags For example the Tag for a diesel vehicle will not be able to dispense fuel from a gasoline pump Or else the Tag for a vehicle belonging to Group 1 may not have fuel dispensed from a pump belonging to Group 2 In this case 1 Introduce the Program Tag and enter the RESTRICTED PARAMETERS MENU see RESTRICTED PARAMETERS MENU 2 Set up the numbering to be assigned to group 1 connected to the M4 terminal strip Numbering pump 1 function Installation Manual Pag 21 Amico Installation and User Manual 3 Set up the numbering to be assigned to group 2 connected to the M5 terminal strip Numbering pump 2 function 4 Set up the type of product to be dispensed by pump 1 2 Numbering pump 1 2 function 5 Set up the code of the affiliation group for pump 1 2 Firm numbering 1 2 function 2 3 1 3 Configuration of customisable parameters Customisable parameters are used to customise control uni
10. stock not available will be returned until such a time as the first refuelling is accomplished 3 2 2 2 Registration of the Manager for reception of the automatic notifications The Manager is the telephone number of the person assigned to receive the alarm SMS on the cistern stock The alarm notifications are for minimum reserve in the cistern and dispenser pump block which may be set in the cistern stock menu When the level goes below the alarm level at each refuelling an alarm SMS is sent to the manager s number To register as manager send an SMS to the AOL module number with the message AOL MANAGER The AOL module will answer with the message You are the new AmicoOnLine manager User Manual Pag 57 Amico Installation and User Manual 4 WinAmiFree management Software WinAmiFree management Software Pag 58 Amico Installation and User Manual 4 1 Introduction The WinAmiFree software gives access to the management of the dispensing data memorised by the Amico equipment allows the entering of the vehicle and driver identification lists creates reports on consumption averages and on litres dispensed allows the downloading of data manages periodic maintenance procedures and at kilometric deadlines and permits AmiTag programming WinAmiFree management Software Pag 59 Amico Installation and User Manual 4 2 Main Screen To launch the program click on the WinAmiFree icon on the PC desktop 5 Win
11. 7 1 Calculation of the stocks with the manual data download on the Data Download AMI AG teeter RE PTT 81 4 7 2 Stock calculation with direct connection via cable eeeeeeeeeeeeeeaes 82 4 7 3 Stock calculation by way of the AmicoOnLine server cece eee eee n nnn nn 84 4 0 Scheauled MalNnCeNnance scenic bad equ D Um elenina 87 4 8 1 Connection to vehicle maintenance enne 87 4 8 2 Verification of expired scheduled maintenance procedUures 90 4 8 3 Saving scheduled maintenance procedures performed a 91 4 8 4 Odometer change and recalculation of the deadlines i 92 4 9 AmiDesktop Programming of the AmiTags eeeeeeeeeeee nne n nnn nane 93 ALOT MWEBIGEUEJMLEDAG aan 93 A202 DRIVER isi tem 96 49 5 Data Download Amilagzia te eria vt Eus dc da eq Nar ieQu IE ALII 97 449 7 Program AMITag rei 98 4 9 5 Command transmission to the Amico control UNIt eee 99 4 9 5 1 Command transmission in the direct cable connection 99 4 9 5 2 Command transmission to the AmicoOnLine Server 99 5 Attachments osn ieseni o P PRIN FR DEERDR PR EE essuussucsceswsausuersedasweeuueeedencucws 102 Dek HCESCONTORMICY DE LI TS UL UTE 103 52 CETO p Dr 104 Bow Sogar T PE 105 5 4 COMPONENU lOCALON san ETT T a Sr eee ay 108 5 5 SpeglficaklOliS dutceumessvetbrvaaa PvE QUO uU hac M CM d via in ea sd da A
12. E REOS ERE E ERIS 44 3 1 3 Error messages during the enabling of the refuelling eese 44 3 1 4 End refuelling memorisation and transmission of data to the AmicoOnLine server 45 Salvo ALG PrograM 25 3 33axa diu E operi vip icEse RA VII DI OLI pk Ra dii gr rPeh s PLcu ca aa EERS 47 Jd CISTERN STOCK MENU ilaria 50 3 Libilit Correcb Stock CISEBETII Ly Zilli EINEN cs 50 3 1 5 1 2 Start Calibratlofi Cistern 1 2 ssxesavec testen Ex ede Fax Vx ENETESEPE S a EST EK LER 50 3 1 5 1 3 Set minimum reserve in Cistern 1 2 ccseesseen mme 50 3 1 5 1 4 Set Dispensing Block Cistern 172 pp MPOIDR a a 51 3 1 5 1 5 Ser Counter PUMP 1 2 uses ILL beter DM I IEEE SI 3 1 5 2 MENU DISABLEVEHICLE AMI AG rie 51 3 1 5 2 1 Disablecan AMITagisail alia aaa aliis 51 3 1 5 2 2 Enable a mAmiT g _ saran alla 51 321352223 List AmiTags Disabled 52 S21 eo 2 Enable TagGs socssri aires Asa A E eh idu os 52 354 522 95 Disapa tag Serai testers edu ele 52 3315523 MENU DISABLE DRIVER AMLUDA G 1 Eb a EG Ee RN ROCCO NR cr EI S QD ER d 52 3 54 MENU AMIGO ON LINE aule 52 31 51 sACtivate GPRS SerVvices iui luisa 53 3 1 0 5 MENU TEST OPRERATION ellerre ai 53 3 1 5 5 L Operational Test ACUVOs lies lillo 53 3 1 5 6 CUSTOMIPARAMETERS MEN ictor ET Da V3 aa 53 3 1 5 0 T1 Set Date and IME suce lan iaia 53 3 1 5 0 2 Secotids Start Reluel ssessscvetudatusie eb Ra a ed a ad e ota Dex OA 53 3 1 5 0 5 SecondsEng
13. L installazione di Amico stata completata con successo I L applicazione pu essere eseguita selezionando le relative Icone Premere Fine per uscire dall installazione Installation Manual Pag 26 Amico Installation and User Manual Press End The WinAmiFree icon will appear on the desktop 2 3 3 Installation of AmiDesktop Contactless In the AmiTag Amico versions it is possible to install an AmiDesktop Contactless Reader optional Connect the reader to the PC and wait for the installation procedure guided by the new hardware Installazione guidata nuovo hardware Installazione quidata nuovo hardware Questa procedura quidata consente di installare il software per China Vision RF Reader USB CvBBDL Se la periferica dotata di un CD o un disco 22 floppy di installazione inserirlo nell apposita unit Scegliere una delle sequenti opzioni CO Installa il software automaticamente scelta consigliata 5 Installa da un elenco o percorso specifica per utenti esperti Per continuare scegliere Avanti Select the checkbox Install by a list or specific path and press Next Installation Manual Pag 27 Amico Installation and User Manual Installazione guidata nuovo hardware Selezionare le opzioni di ricerca e di installazione Ricerca il miglior driver disponibile in questi percorsi Utilizzare le caselle di controllo che seguono per limitare o espandere la ricerca predefi
14. archive to look at the last but no less important procedure for the completion of the description of the main functions The reports seen up to now are not very legible in that for identification of the vehicles there has been a number that corresponds exclusively to the AmiTags It is therefore necessary to create a table with the license plate and the description of the vehicles and associate it to the Tag number so as to improve the report analysis Click the Vehicle button Installation Manual Pag 39 Amico Installation and User Manual anagrafica Automezzi E X Numero Targa e descrizione iniziale per il conta ore Gruppo di appartenenza T m Li IMPORTA X Esci PR Elenca 3 Nuovo fff Cancella The vehicle archive is still empty Click the New button and the first vehicle record of the table will be created with the number 1 Click a few times on the New button to prepare the list of vehicles to be entered and then enter in the license plate and description columns the information for each vehicle IMPORTANT Entering the asterisk as the first character the program assumes that the vehicle has no odometer but a time counter Consequently in the consumption averages report the consumption will be indicated with the ratio of Litres Hour instead of Km Litre For a detailed description of the functions shown see paragraph 4 3 2 Vehicle identification list Installation Manual Pag 40 Amic
15. belonging to that particular company For example setting 1 as the company number on pump 1 and 2 as the company number on pump 2 the AmiTags with company 1 limitations will be able to refuel only from pump dispenser 1 3 1 5 7 6 Contact Dispenser unit 1 2 This allows the blocking of refuelling upon replacement of the dispenser hand unit in its seat without waiting for the end refuelling timer In order to function the dispenser hand unit contact must be connected to the Amico I O 3 1 5 7 7 Analogue Level Sensor Probe 1 2 This allows the enabling of the analogue level sensor probe 0 5 V 3 1 5 7 8 AmiBus Level Sensor Probe 1 2 This allows the management of the cistern level to be enabled by way of a sensor probe connected to the AmiBus 3 1 5 7 9 Calibration in the sensor probe If the calibration table of the cistern has been entered into the sensor probe set this heading Amico will ask the sensor probe for the number of litres in the cistern and not just the mm 3 1 5 7 10 Number set litre 1 2 This allows the indication of the numbers litre transmitted by the encoder assembled to the heads of the distributor pumps Before changing the number of impulses litre User Manual Pag 55 Amico Installation and User Manual e Download the data from the personal computer e Zero out the total litres dispensed versions with internal printer e Notify the stock and electronic counter values After having changed the number
16. identified by the pump number 1 numbering by Amico which is connected to it Button to change the description of the cistern 8 Date and time of the last change in the stock on the AmicoOnLine server WinAmiFree management Software Pag 84 Amico Installation and User Manual To enter a replenishment of the cistern enter the litres to be added to the stock in the data entry window 3 and click the Apporto button To correct the current stock enter the current litres in stock in the data entry window 3 and click the button To visualise the history of the replenishments and the transfers carried out on the cistern Rapporto dei carichi in cisterna selected click on the button AmicoOnLine fmc AE EN ONLINE wm BR 0 N e To request a report for all of the cisterns connected click the button WinAmiFree management Software eta 11 30 APEPRE Date and time of the insertion Litres added in the variation ES IACHE Elenco carichi in cisterna a isterna collegata Blla pompe Operazione Ciac SA Nubva 000987 001987 20 01 2009 17 33 STORNO 001000 005914 001000 Type of operation carried out addition or transfer correction Stock in cistern before the variation Stock in cistern after the variation Rapporto cisteme Pag 85 Amico Installation and User Manual AmicoOnLine WinAmiFree management Software Codice Amico 2000 oo Config i e
17. internet from the control unit to the PC The download to the PC comes about by way of the AmiDesktop Contactless Programmer optional which transfers data from the Data Download AmiTag to the WinAmiFree software 1 3 1 5 WinAmiFree Software distributed on CD Management software included in the Amico System with operational functions for e Acquiring data from the Amico control unit e Managing driver and vehicle registration e Analysing consumption e Managing programmed maintenance e Programming AmiTags Software CD Figure 4 Product Description Pag 11 Amico Installation and User Manual 2 Installation Manual Installation Manual Pag 12 Amico Installation and User Manual 2 1 Installation and Maintenance WARNINGS gt Installation of the Amico device must be carried out by specialised personnel who have been suitably trained gt i The Amico device is intended for use with a mono phase electrical network Therefore all of the regulations and laws regarding safety must be observed b In the device there are parts that are under dangerous electrical voltage when used The improper utilisation of these devices may therefore cause serious harm significant damage to things and even death In addition the installation instructions must be scrupulously followed P Amico must arrive from shipping protected from shocks by suitable padding If there IS evidence of damage contact the manufacturer in t
18. into the driver identification List Anagrafica Autisti Home e descrizione 3 Nuovo Tif Cancella x salva B LJ IMPORTA X Esci N To insert a new driver click on the button pem will be entered that is higher than the last one entered A new driver identification number WinAmiFree management Software Pag 61 Amico Installation and User Manual Anagrafica Autisti Nome e descrizione Binotti Fabrizio Gabetta Massimiliano gt Nuovo Cancella _ Salva iSElenca IMPORTA X Esci The button gt Penca allows the Windows Report to be opened with the list of the drivers entered so as to allow its printing or insertion on the clipboard Report Window WinAmiFree r 01 11 10 c 2001 2009 by fabrizio binotti com Elenco degli autisti in archivio 2 0001 Binotti Fabrizio 000 Gabetta Massimiliano 4 3 2 Vehicle identification list The vehicle number must correspond to the vehicle number on the AmiTag which will be assigned to it or else the vehicle number entered by the operator in the AmiTag Driver function Enter vehicle number Automezzi Click the button to enter into the vehicle identification list WinAmiFree management Software Pag 62 Amico Installation and User Manual Anagrafica Automezzi Targa e descrizione iniziale per il conta ore Gruppo di appartenenza Nuovo ff Cancella Elenca EJ IMPORTA X Esci To insert a n
19. may refuel It identifies the user It must be communicated when requesting new AmiTags Card Number the Data Download AmiTag must always be numbered 1 Download Messages indicates the actual status of the AmiTags These statuses may be e Normal download Inserting it in the Amico the oldest 100 refuellings in memory will be downloaded e Backup download Inserting it in the Amico the last 800 refuellings will be recovered and the 100 oldest will be downloaded e Download OK there is data to be downloaded from the WinAmiFree software The AmiTag will not be able to be used any longer to download data until its Scarico dati dalla carta zeroing out with the button in the main screen e Backup Ok There are backup data to be downloaded e Download Error The download was not completed Repeat the operation e Backup Error The setting up of the backup download was not completed Repeat the operation e Partial Download The download was successfully completed but there are still refuellings in the Amico memory Download the data again Last download Date and time of the last data download Dispenser Number 1 indicates the numbering given to pump 1 Dispenser Number 2 indicates the numbering given to pump 2 Stock 1 indicates the stock in the Amico display at the moment of the data download Pump 1 Impulses indicates the number of impulses per litre for pump 1 Pump 2 Impulses indicates the number of impulses per litre for pump 2 Butto
20. of impulses litre Correct the settings of the cistern stocks and the electronic counters Check and verify the truthfulness of the data set by way of fuel dispensing 3 1 5 7 11 Self calibration pump 1 2 This is used to manually change the number of impulses litre by 0 1 units more or less 3 1 5 7 12 Zero out operations memory Completely zeroes out the refuelling memory 3 1 5 7 13 Modify machine code Allows the variation of the Amico Machine Code so as to be able to attribute it to a new user User Manual Pag 56 Amico Installation and User Manual 3 2 SMS function from a cell phone to AmicoOnLine A series of functions recallable by way of SMS from a cell phone in the AmicoOnLine versions are available The telephonic SIM card in the AOL module must be enabled for sending SMS Short Message Service 3 2 1 List of Commands AOL GIAC Requests the stock in the cistern AOL GESTORE Requests the registration as manager of the alerts 3 2 2 Description of SMS Commands 3 2 2 1 Requests the stock in the cistern In order to receive the stock in the cistern value in real time send an SMS to the telephone number of the AOL module with the message AOL GIAC The AOL module will send a return message to the number that made the request with the stock in the cistern tank The AOL module receives the stock value at the end of each refuelling If the request were to arrive after turning off the Amico control unit the message
21. permission of the command data card activates the following outputs in parallel e Output 24V AC to command a remote control switch on terminals 6 7 of the M5 terminal strip e An NA contact that closes to interrupt permission max 12 V 0 3A on terminals 8 9 of the M5 terminal strip Installation Manual Pag 17 Amico Installation and User Manual 2 2 3 Connection of the mini modem to the PC optional The connection of the Amico control unit to the PC comes about through a shielded 8 wire cable 0 5 mm 2 that connects the pair of mini modems One mini modem is positioned inside of the Amico control unit and the other is connected to the serial port of the PC M4 terminal strip Figure 8 Mini modem PC side Figure 9 The two mini modems are connected to the M4 terminal strip 6 contacts doubling the wires on terminals 1 2 9V AC power supply from the mini modem transformer PC side The connection is made respecting the sequence on both of the connectors Mini modem Amico side M4 Mini modem PC side M4 9 1 Degas eee 2 Be 3 jj asec tees basaee sere 4 Bee 5 6 ane 6 The mini modem PC side connects to the serial port or to the USB 232 adapter on the PC and is powered by a transformer from the 220 V AC mains Installation Manual Pag 18 Amico Installation and User Manual 2 2 4 Installation of the AmicoOnLine AOL module for internet connection by way of the GPRS optional The connection of the Amico
22. requests that will be carried out by the Amico control unit There are different types of AmiTags independent of the format chosen key rings or pass cards To enter into the AmiTag programming bring the AmiTag close to the reader and click the button INED In the screen of the AmiTag reading each field has 2 data boxes the left one in grey without possibility of modification is the reading of the parameters the right one in white is the mask for the new values that will be written on the AmiTag 4 9 1 VEHICLE AMITAG WinAmiFree Lom 1 iss l Tipo Carta jAutomezzo Stato tessera 2 I I Blocca il rifornimento in funzione dei km Errori nel CK 0 EHIPBRIVE 23 24 25 26 21 1 Window for the functions that may be set to enable refuelling 2 Window for the check of kilometres and the predetermination of consumption WinAmiFree management Software Pag 93 Amico Installation and User Manual 10 11 12 13 14 15 16 17 18 19 20 WinAmiFree Window for the blockages in multiple plant systems Request for kilometres read on the odometer This function is necessary for the calculation of consumption averages Request for the hours read on the vehicle counter substitutes the kilometre request Request driver card this is requested at the insertion of a driver type AmiTag for his her identification Litre deduction limitation only for previous systems S
23. to avoid too long a wait for the operators to carry out their refuellings Therefore a sufficient number of refuellings will have User Manual Pag 46 Amico Installation and User Manual to be carried out so that all of the refuellings are transmitted to the server The server will not calculate the reserve stock for Amico because it is not capable of calculating it correctly until all of the refuellings have been completely transmitted 3 1 5 AmiTag Program The AmiTag Program is a special card that allows the fuel depot manager to operate Amico SO as to obtain reports on refuelling carried out update the fuel stock levels in the cisterns disable supply cards modify certain timers and operational parameters and transfer the list of the driver codes enabled for refuelling Introduce the program card into the reader On the display the following message will appear The list of driver codes loaded on the Data Download AmiTag is loaded into the Amico memory even if they are not used The driver codes are used to identify the operators through entering a secret code when it is specified by the Request driver code function on the Vehicle AmiTag 99 is the maximum number of driver codes These are programmed by the WinAmiFree software through the AmiDesktop Contactless programmer on the AmiTag program see link and afterwards STOCK MENU To navigate the menus and functions refer to the program card diagram The rules for nav
24. to its spacers on the lower panel e Enable the management of the sensor probe with the Program Tag in the Sensor Probe on AmiBus function in the RESTRICTED PARAMETERS MENU see AmiBus Level Sensor Probe 1 2 Installation of the AmiBus module Figure 11 Installation Manual Pag 20 Amico Installation and User Manual 2 3 Configuration of the Amico System 2 3 1 Configuration of the Amico control unit Initial configuration allows the Amico control unit to know the details of the refuelling plant system the number of dispenser pumps and cistern tanks connected the numbering to assign to the dispenser units in a plant with more than one dispensing device the type of product dispensed and the code of the company to which the dispensers belong 2 3 1 1 Configuration of the plant system parameters 1 Introduce the Program Tag and enter the RESTRICTED PARAMETRS MENU see RESTRICTED PARAMETERS MENU 2 Set up the second pump connected to the M5 terminal strip if there is a second pump SET UP PUMP 2 function 3 Set up the second cistern tank if the 2 pumps are connected to 2 cisterns SET UP CISTERN 2 function 4 Set the number of litre impulses in the encoders connected to the pumps NUMBER OF IMPULSES PUMPS 1 2 function 5 Set up the level detection function from the sensor probe ANALOGUE LEVEL SENSOR PROBE function or LEVEL SENSOR PROBE ON AMIBUS 2 3 1 2 Configuration of parameters for a multiple
25. 1 11 10 c 2001 2009 by fabrizio binotti com Ultimi dati acquisiti Data e ora Mezzo Autista Km o Ore Litri Pompa 05 11 2008 11 34 0001 0000 000234 0000 4 01 AA 000 BB IVECO 190 Totali erogati per automezzo Carta Totale litri Km a ultimo rifornimento 0001 0000000 49 000234 AA 000 BB IVECO 190 Totali erogati per Pompa Pompa Totale litri 0001 The date and time of the refuelling AmiTag number that refuelled the driver number only with the 2 AmiTags function and the kilometres on the odometer at the moment of the refuelling and the litres dispensed are listed At the end of the refuelling list there is a summary of the total litres dispensed from that pump and by AmiTag The last data download report is of little significance It is much more interesting to be able to request a report for a given period and to be able to list the refuellings grouping them by vehicle so as to be able to analyse consumption To do this click on the Historical Archive button Installation Manual Pag 36 Amico Installation and User Manual WinAmiFree Acquisizione Dati Corregge Data e Ora Disabilita o Abilita Carte Giacenza in cisterna km errati Limita o Preseleziona p Caratteri ricevuti 0 Errori nel CK 0 Lo Archivio Storico Dall inizio del mese scorsa Rifornimenti Esterni Da gioved 1 gennaio 2009 A mercoledi 25 febbraio 2009 ma Prodotto Tutti i prodotti Automezzo E Sul
26. 197 0771996 04 48 0001 042876 D22 gda Oras O2 60 Cl 22 07 1996 17 43 o001 043499 O162 56 523 03 41 l 2401996 11 58 0001 0433139 Dis o DI 426 07 71996 15 05 o001 O45 DL O436 14 dina 05 46 Ol 2970771996 16 16 0001 046229 O2 2 20 0528 O2 16 l 300771996 16 05 0001 46890 oll 86 OBO 1 3 30 l p 3170771996 17 52 OO01 Di 03 O166 52 1513 3 08 Dl Totale litri erogati 4611 5 Consumo medio in kml 03 14 Chilometri percorsi calcolab1 1 12558 Automezzo 30524 Data e ora Autista Km Litri Percorsi Km L P Nome autista m Ld NENNEN The list of the refuellings carried out on this vehicle may be seen for the period considered The refuellings data are the date the time the driver only using the second pass card the litres dispensed and from the second refuelling of the period the kilometres driven and the consumption average in Km litre Analysing the different refuelling lines it may be noted that the refuelling of 24 07 1996 has a kilometre setting that is surely in error Indeed the previous ones are higher The consumption cannot be calculated Clicking on the refuelling of 24 07 1996 a window opens that allows the kilometres entered to be manually corrected so as to be able to verify consumption Lorrezione dei chilometri E x Humero commessa ono Varia num automezzo 0000 Data e Ora Autista Chilometri Litri Percorsi Km LitriOre 2233517543 Bn 043499 0182 56 0623 U3 41 03 4 24 07 1996 11
27. 2 0 firmware of the Amico control unit e WinAmiFree r1 11 10 e AmiOnLine r 2 1 2 Product Description Pag 9 Amico Installation and User Manual 1 3 Amico System Elements The Amico System is made up of the following elements 1 3 1 1 The Amico control unit This is the principal component of the Amico System It is positioned next to the fuel dispenser pump and controls supply by way of AmiTag authorisation keys 09 8 2 3 4 i O00900 AGO eaa The Amico control unit Figure1 1 3 1 2 AmiTag Keychain and card for enabling refuelling This is utilised to identify the vehicle or the driver allows the pre authorisation and the tracking of refuelling supply Product Description Pag 10 Amico Installation and User Manual http www binotti com MICO Scarico Dati 0002 ian bin oey M AmiTag in key ring format Figure 2 AmiTag in Card format Figure 3 1 3 1 3 AmiTag Program The AmiTag Program is a special card that allows the fuel depot manager to operate Amico so as to obtain reports on refuellings carried out update the fuel stock levels in the cisterns disable supply cards and modify certain timers and operational parameters 1 3 1 4 AmiTag Data Download The Data Download AmiTags are particular card passes that allow a manual downloading of the refuelling operations memorised in Amico and their subsequent transfer into a PC when there is no direct connection by cable through the
28. 58 Joon 143313 0352 76 267077 335 15 05 ooo 045701 435 14 2382 05 46 Ti Cancella Installation Manual Pag 38 Amico Installation and User Manual The refuelling selected is in a central position preceded and followed by 2 others Moving by trial the presumed kilometrage entered at 044319 and in the data cell Km L the consumption is immediately calculated based upon the new kilometres entered Correzione dei chilometri x Humero commessa food Varia num automezzo 0000 Data e Ora Autista Chilometri Litri Percorsi Em LitriOre 22 071 335 17 43 oon 043455 0182 56 0623 02 41 13 4 24 071 33b 11 58 foon 044318 0352 76 ogei 02 32 00 43 26 07 1996 15 05 Joon 045701 435 14 Taag 05 1E 03 16 TT Cancella Modifica X Chiudi Another system for correcting the Km is that of having them coincide with the next refuelling The consumption will be calculated on the next refuelling with the sum of litres dispensed in the two refuellings Correzione dei chilometri x Humero commessa Joo Vana num automezzo oono Data e Ora Autista Chilometri Litri Percorsi Km Litriore e2 OF 1956 17 43 Joon 043455 0182 56 0623 03 4 02 41 24 0771 335 11 58 Joon 045701 0352 76 222 05 24 00 16 26 07 1996 15 05 coni 045701 435 14 Ji 02 79 02 79 T Cancella X chiudi Click on the Save button and the changes are saved in the refuelling archive ic Modifica Exit the historical
29. AmiFree m bd MICO Ultimi Dati Acquisiti La Men GE MIS SR GER Archivio Storico Automezzi 8 10 Autisti Manutenzioni Cisterne Ami DeskTop 9 11 Caratteri ricevuti Errori nel CK 0 COMS AmiDeskCL ice 1 This is the button for the execution of the AmicoOnLine software and for connection to the On Line versions of Amico Language Selection System events record Automatic data acquisition each hour from the direct cable connection Remote telephone connection or by IP address Verify new updates on Internet Download data from the Data download AmiTag Buttons for the management of data and the identification lists E cole o E M E AmiDesktop for the programming of the AmiTags 10 Buttons for direct connection by cable 11 Software version download the latest version and remote assistance help 12 Status Bar WinAmiFree management Software Pag 60 Amico Installation and User Manual 4 3 Identification lists The identification lists allow the association of the AmiTag number to the description of the vehicle or to the driver operator who will carry out the refuelling to improve the legibility and interpretation of the reports 4 3 1 Driver Identification List The driver number must correspond to the driver number on the AmiTag that will be given to him her or else to the number associated with the driver code on the AmiTag program Autisti Click the button to enter
30. AmiTag Program in the Amico control unit to transfer the codes there User Manual Pag 43 Amico Installation and User Manual e Set up the Request driver code function on the Vehicle AmiTags which will have to request the driver code Once the Vehicle AmiTags are introduced there will be a request for a driver code to be entered and that code will be substituted in the refuelling memory with the corresponding driver number 3 1 2 1 3 Request job order number cost centre The job order number is a 2 number code that is requested of the operator as additional information There are no checks made on this data entered In the historical archive of the WinAmiFree software it is possible to put a filter on the job order number so as to have only the refuellings with that job order number This is a generic function for the resolution of different situations 3 1 2 1 4 Request dispenser number When Amico is configured with 2 pumps before refuelling there is a request made for which pump will be used The selection comes about automatically when e There is only one pump connected to Amico e One pump is already in use e There are limitations on the pump number on the company or on the product to be dispensed e A cistern tank is empty and there is a block on the stock reserve in the active cistern tank 3 1 2 1 5 Entry of outside refuelling data Refuelling carried out with dispensers not connected to the Amico equipment s
31. ENU TEST OPERATION MENU CUSTOM PARAMETERS RESTRICTED PARAMETERS MENU Set Date and Time Seconds Start Refuel Seconds End Refuel Set up Pump 2 g Ta D DE D gt 3 o a rm S Q Gi D Enable AmiTag 3 ni CU Q List AmiTags List AmiTags Enable all Enable all Tags ags Disable all Tags Disable Block Dispensing Counter Pump 1 IER U D CU O ct 5N U z DO gt gt HO z Z Z o D 2 o C Do 3 gt o C C C a Sa 3 fas o 2 3 3 3 Oo O sy O A4 o Qj o o o c b 0c T e O D D D lt S o I c e J 3 a ge v O D D v 5 5 5 O e c D o5 lt T a a a D D 5 lt UO O U U 5 S o n D D O A C O O 2 D a D D UO E I a T 3 9 D 5 e x m c D O 9 5 lt rm m ct rm User Manual Pag 49 Amico Installation and User Manual Only if the AmicoOnLine function is not active and there is no level sensor probe Only if there is the second cistern Only if there is the level sensor probe and the calibration is not in the probe Only if there is a pump no 2 3 1 5 1 CISTERN STOCK MENU The stock menu allows the operations of replenishment of the cisterns the setting of the control levels on the reserves to be recorded and the setting of the electronic pump counters connected The sub menus that have to do with the second cistern or the second pump are active only in the case of the actual connection of a second pump or a seco
32. MA Amico L installazione o l uso del software AMICO il Prodotto implica l accettazione da parte dell utente Concessionario delle condizioni riportate nel presente accordo Qualora non si accettino termini in esso contenuti selezionare il pulsante di annullamento dell installazione Nel presente accordo il Concessore di licenza e Accetto termini del contratto di licenza Non accetto i termini del contratto di licenza Select the checkbox I accept the contract license terms and press Next Avanti NE io Installazione di Amico Selezione della cartella di installazione Dove vuol installare amp mica mit iJ Amico sar installato nella sequente cartella Per continuare premere Avanti Per scegliere un altra cartella premere Sfoglia c amicd Sono richiesti almeno 5 7 ME di spazio sul disco Installation Manual Amico Installation and User Manual Select the destination folder for the program and press Next Avanti ie Installazione di Amico Fi E3 cy Selezione della cartella nel Menu AvviofStart Dove vuoi che l installazione inserisca collegamenti al programma el Saranno creati collegamenti al programma nella seguente cartella del Menu HH Avvio Start Fer continuare premere Avanti Per selezionare un altra cartella premere Sfoglia Press Next and then Install az s te Installazione di Amico Completamento dell installazione di Amico
33. MART CARD T DR Kj 170 17R ce u CR2038 AMICO 2005 NIe o o sisi si SIR Sg INTERFACCIA be n ee Lr uuu binotti com AJ peace o ee i Si 82412 5 Amico 2005 Figure 20 Attachments Pag 108 Amico Installation and User Manual http www binotti com J AMICO 1 0 R2 8 PA 3 3C20 in i12UAC 24U C 24UAC PA FA 12 24UAC INTERFACCIA AUTOMATICO MANUALE u m T N I c I N ut m 2 Tr N I amp 0 220Uac x JP1 JP OUT MOTORE 1 POMPA 1 FS 7a 220Vac 19A 3 DANGER HIGH VOLTAGE Amico I O Figure 21 Attachments Pag 109 Amico Installation and User Manual EE Pii 52 mE OFF i1 x ma jau MO e SUL T5 m e E Ici Si si Zu c42 d al o Ho BRE Ie IC4 OKs IC3 OEC s DE R2 ie 5 a 88 uyw binotti com RX TX RL UDO C46 z c it Cd eio C17 EN e TG C413 C 1C2 D un SS er 63 C18 ca DD DM E T4 R3 4 c14 NRW IC coq ICE EE cts Z m C21 im e qo m 103 C56 rs D 104 p E S 45U iE B ag R C10 ER so E m cis amp wuu binotti com LK om US gu D C11 C12 Micro P 44R2 0 SUI 1 39 CPU Module Figure 23 Attachments Pag 110 Amico Installation and User Manual Model AOL Figure 24 Attachments Pag 111 Amico Installation and User Manual 5 5 Specifications Device power supply 220V 15 Minimum basic op
34. MICO d MA 4 4 AE a Installation and User Manual version 2 0 revision 38 D PIE ai dh i C ere E m p E si A Ok 0 1 2 3 4 No 8 6 7 8 9 DDIOD Index 1 ProductDescription ii dE aC REKEEPVERPEERE RREREEUFERWFEE NIKE 7 Li Use iHencC c In 8 L 2 VAMICONErSIONS ssi oiran anta DRPcss RR RRNPIDER arno 9 1 5 AMico system Elements rail UH rU SUSCENSEetun 10 ESAL 3Rhe Amico CODLEOI UIE tsseeceressercucessccusesveecterided qe GocEEc o POSSPEETS DUPDASUNDTRPRENYY PIS 10 1 3 1 2 AmiTag Keychain and card for enabling refuelling eese 10 1 29 1 5 AMIT29 Programmi lai 11 1 5 1 4 Amad Data Dowhlodd ssaa alia abissi 11 1 3 1 5 WinAmiFree Software distributed on CD eeeeeeeeee nnn nnn nnn nnn 11 2 Installation Manlud dl 2 23 93 pruREEREREESARRA RNREEREREEEEEREREREIRRRERERERRKRSEFARRRSRNAEREEREEEENS EE 12 2 1 Installation and Maintenance WARNINGS nme nnn nnn aaa nnn nnn nnns 13 2 2 Installation of the Amico Control UNit nennen nnn nnn nnn nni 14 2 2 L System COMPONE M Saana denuo eeeh DR DE 14 22 2 Installation SEQUEnNce ssaa 16 2 2 3 Connection of the mini modem to the PC optional i 18 2 2 4 Installation of the AmicoOnLine AOL module for internet connection by way of tne GPRS 0pronal oraria Em 19 2 2 5 Installation of the AmiBus module for connection of the level probe
35. MS to the manager 3 1 5 4 1 Activate GPRS services Ok Press 1 and OK to activate the connection to the AmicoOnLine server 3 1 5 5 MENU TEST OPERATION This is used to carry out general operational tests of the Amico control unit 3 1 5 5 1 Operational Test Active This function performs a test on all of the electronic components verifies the organisation of the memory Data Check etc Eventual problems are highlighted on the display notify service assistance 3 1 5 6 CUSTOM PARAMETERS MENU The custom parameters are those parameters that are variable from one plant to another as a consequence of what kind of use is requested of Amico and of its position in the fuelling plaza 3 1 5 6 1 Set Date and Time This allows the update of the Amico internal clock calendar Enter the parameters requested in sequence and OD The parameters requested are e Enter the year e Enter the month e Enter the day e Enter the time 0 23 e Enter the minutes 3 1 5 6 2 Seconds Start Refuel This allows the variation of the number of seconds from the enabling of the refuelling to the beginning of the refuelling If within this time in seconds refuelling does not begin Amico disconnects the dispenser requiring the reinsertion of the AmiTag It is set at 60 seconds oR Enter the number of seconds and press User Manual Pag 53 Amico Installation and User Manual 3 1 5 6 3 Seconds End Refuel This allows the number of seconds fro
36. PM Ariadna uS OE 112 6 Index ofthe figures 116 Product Description Amico Installation and User Manual 1 Product Description The Amico System was conceived for rendering fuel replenishment consumption management tank filling operations and motor vehicle maintenance automatic The main function of the Amico System is to permit the supply of fuel in a controlled and pre authorised manner The access key for refuelling is a vicinity activated RFID tag AmiTag provided with memory for programming operational parameters AmiTags are able to be customised by way of their programmer setting of kilometres or of work hours request of a secret code request for a second card for driver identification request of a driver identification code limitations and pre selection of the litres to be pumped as a function of the estimated average consumption etc Amico conditions refuelling based upon the information memorised on the AmiTag that is brought near the reader It may be combined with new or already existent distribution plant systems It is able to manage supply from two fuel dispenser pumps at the same time It is able to manage the cistern fuel stock in real time permitting the setting of a minimum supply level with eventual fuel dispenser pump blocking It is able to manage two electronic counters which synchronised with the mechanical ones give the possibility of knowing if the electronic one has been excluded from the pumps
37. a mobile telephone provider is necessary Type of calling Modem GSM GPRS oo Hocem l PLEASE NOTE Average time required for download at the end of refuelling is 1 min Attachments Pag 115 Amico Installation and User Manual 6 Index of the figures The XAmicocontrol dri FIGUE L ilaele Pr tr ueni riui aea adu eae INS 10 AmiTag in key ring format Figure 2 AmiTag in Card format Figure 3 11 SOFtWare CbDCEIOGUE e Scusa vita diee RERO II HEN Md dca anm bua tI ra dS EHE 11 Amico Control Unit detall Figure 5 iii aaa 14 Insiae or th control unit FIgUEG G xuasesuukan A IKE NSRRASERERRRUFENRERUREMREREWRRRUFERRODYRARUEENASAAA VPERERPA 15 Amico I O xdata Card FIGUPE 7 5 2 indaga torta RI ERDXDUOT RR EY PEE 16 M4 terminal strip Figure 8 Mini modem PC side Figure 9 cem nnn 18 Positioning of the AmicoOnLine GPRS modem card Figure 10 i 19 Installation of the AmiBus module Figure 11 eeeeeeeeeeeeeee en nnn nnn nnn 20 Declaration or CE conformity Figure 2 8i ener DU a i X Ed s Ho a Na OE ES E DER dr Sa tates 103 CE Tad FIOO iaia lee ely 104 Container CA OT FIGURE 14 pla a ea iA aula alla 105 Container CA 02 Figure 15 it tore rr hr Ex Re Ea pORDESESEIEIIh Nc Ec P Qe Qa Rr I EX RT e RD Kee ieee 105 Container C As05 Figure EO zaia ea ateneo tps tet dudo 106 Container CA O4 CFEIgUEe T7 5 suibsnses ia ERE re a oit sv aeree 106 Container CA 05 FIgure T8 rrr
38. aa aaa aT 107 AMIBUS FIQUE TO aacouet5s PE 108 AMICO 2005S Figuro 20 Jere TC 108 AMICO NVO Figures ZI Jae a PO M MU a a E 109 Micr modem Figure 22 ec rc T 110 CPU Module FIUO 25 aveduero diste onda O a a ones 110 M del AOL FIGUIC 24 2 ceris naaa a uw a rk ze isla 4a a aadi 111 Index of the figures Pag 116 Amico Installation and User Manual End Manual Index of the figures Pag 117
39. ag 96 Amico Installation and User Manual 9 Button to write the AmiTag and increase by one the card number and the driver number This is used when several AmiTags are to be written in succession 10 Button to reload the parameters of a card that was saved 11 Button to save the parameters of this card so as to be able to recall them 12 Card type the Driver AmiTag is used to identify the operator who is carrying out the refuelling 13 Card pass status may be OK for a valid AmiTag or DISABLED if it has been inserted in the control unit after having been disabled 4 9 3 Data Download AmiTag The Data Download AmiTag allows a manual transfer of refuelling data from the Amico control unit to the PC On one Data Download AmiTag about 100 refuellings may be transferred any remaining will be transferred on the next download The Data Download AmiTag may also be used to recover the last 800 refuellings memorised by the Amico system in the event in which there were a need to recover them WinAmiFree a 1 15 Ra Codice macchina Tipo Carta n OO o omi s 3 O i l a Temm s ERES 2 Hene PA Han a li Giacenza 1 Giacenza 2 1977721 eene EET o p Caratteri ricevuti Errori nel CK O CHIPDRIVE WinAmiFree management Software Pag 97 Amico 17 18 19 20 Installation and User Manual Machine code is the number that identifies the Amico control unit or a group of Amico equipment on which the same AmiTag
40. ar WinAmiFree management Software Pag 69 Amico Installation and User Manual WinAmiFree Lo scarico effettuato da questa carta e parziale Re introdurre la carta di scarico dati nell Amico per scaricare altri dati It is necessary to insert another Data Download AmiTag into Amico to finish the data download In the event that there were problems with the data download caused by wear of the AmiTag it is possible to recover the last 800 refuellings memorised from the Amico memory and re download them programming a backup download on the Data Download AmiTag For this function see the paragraph Data Download AmiTag 4 5 2 Functions for data download from a direct connection by way of cable To download data from a direct connection by way of cable click on the button Acquisizione Dati The data download request is sent to Amico connected by way of a cable Report Window Acquisizione dati del 25 02 2009 15 06 02 Codice macchina 0 Giacenze 4 gt 999999 2 gt 0 Totalizzatori 4 gt 0 2 gt 0 Acquisizione terminata 435 rifornimenti acquisiti Fine scarico Acquisizione terminata Generally only one Amico is connected to a PC during the cable connection In certain cases there may be more than one serial port with several Amicos connected Otherwise the connection may be made through the use of a TCP 232 converter which makes a virtual serial port in a TCP socket In this case in order to ma
41. cistern again The calibration will end automatically From this moment onward the cistern level will be calculated by the value received from the probe sensor 2 3 2 Installation of the WinAmiFree Software The WinAmiFree Software allows the management of refuellings registered by the Amico control unit on a PC Currently WinAmiFree has been developed only for Windows platforms from Windows 98 to Vista 2 3 2 1 Step by step instructions Insert the installation CD in the reader to start up the automatic installation procedure If it does not start up automatically it will be necessary to start up the program manually from the CD file amicosp bat fe Installazione di Amico Benvenuti nel programma di installazione di Amico W in amp miFree sar installato sul computer Si consiglia di chiudere tutte le applicazioni attive prima di procedere Premere Avanti per continuare o Annulla per uscire Installation Manual Pag 24 Amico Installation and User Manual Press Next NE y te Installazione di Amico Contratto di licenza Leggere con attenzione le informazioni che seguono prima di procedere Leggere il seguente contratto di licenza necessario accettare tutti i termini del contratto per procedere can l installazione L UTILIZZO DEL PROGRAMMA AMICO E CONSENTITO ESCLUSIVAMENTE AGLI UTILIZZATORI DI APPARECCHIATURE ELETTRONICHE AMICO S00 900 1000 2000 2002 CONTRATTO DI LICENZA D USO PER IL PROGRAM
42. control unit to the Internet comes about by way of a GPRS enabled telephone SIM card data or voice the activation request for GPRS service must be made through a local GSM telephone service provider Insert the telephone SIM card in a normal cell phone and deactivate the request for the PIN code Insert the SIM in the SIM port of the AmicoOnLine module and lock it in by sliding the lock into place Screw down the 4 spacers on the bottom of the container and attach the AmicoOnLine electronic data card Connect the telephone jack to the AmicoOnLine electronic data card mini modem and to the Amico 3000 electronic data card Turn on the Amico control unit introduce the Program AmiTag activate the Activate GPRS Services function in the AMICO ON LINE menu see AmiTag Program Positioning of the AmicoOnLine GPRS modem card Figure 10 Installation Manual Pag 19 Amico Installation and User Manual 2 2 5 Installation of the AmiBus module for connection of the level probe sensor The AmiBus electronic data card permits the connection of the electronic data card to the level probe sensor For the connection to the probe sensor data card refer to the specific diagram e Connect the RJIN connector to the Amico2005 electronic data card and the RJOUT connector to the Amico mini modem or to the AOL electronic data card by way of the cables provided e Connect the serial cable to the level sensor probe e Assemble the AmiBus data card
43. ctivated INC 3 1 5 1 4 Set Dispensing Block Cistern 1 2 This allows the setting of a blocking level for the stock in the cistern beyond which the operator will be notified at the moment of refuelling with a message on the Amico display Refuelling will not be enabled until a new replenishment of the stock has taken place Ok Enter the number of litres at which point a block in the cistern will be activated e OK 3 1 5 1 5 Set Counter Pump 1 2 This allows the setting of the electronic counter of the litres dispensed from the pump permitting the verification that the Amico electronics were excluded during refuelling Enter the number of litres indicated by the mechanical pump counter without decimals and Ok press 3 1 5 2 MENU DISABLE VEHICLE AMITAG This allows the Vehicle AmiTag to be disabled if lost or not yet issued The AmiTags are disabled in the Amico memory If they were to be inserted into the reader the AmiTag would be disabled ATTENTION The AmiTag number to be disabled is the card number not the vehicle number 3 1 5 2 1 Disable an AmiTag Ok Enter the Tag number to be disabled and push OW Note the same operation may be made by the Personal Computer in the equipment connected by cable or to AmicoOnLine 3 1 5 2 2 Enable an AmiTag Enter the Tag number to be enabled and push User Manual Pag 51 Amico Installation and User Manual Note the same operation may be made by the Personal Compu
44. ctrical power input 1 neutral 2 phase e Earth e OUT 220 V AC 220V 50Hz electrical power output max 5A e F1 F2 fuses e M4 M5 terminal strip respectively pump 1 and pump 2 if present Pin configuration 1 2 Fuel dispenser hand unit contact optional connection Manages a micro switch with a clean contact to activate the pump motor outputs With the contact closed the outputs are enabled 6 7 8 9 and OUT 220 on pump 1 To activate it remove the jumper JP1 pump 1 and JP2 pump 2 E 12 V DC for encoder electrical power supply 4 OV encoder 5 Encoder Channel 6 7 Out 24 V AC for the remote control switch coil The remote control switch allows the power supply disconnection of a dispenser pump with a 380 V AC motor 8 9 Clean contact NC The contact is closed when the dispenser pump is enabled e JP1 JP2 JUMPER to activate the management of the fuel dispenser hand unit in the terminal strip M4 M5 terminals 1 2 remove the Jumper The pump motor may be commanded in the following ways PUMP 1 The permission of the command data card activates the following outputs in parallel e 220v 50Hz output on the OUT MOTOR terminal strip to provide electrical power directly to a small motor max 5A e Output 24V AC to command a remote control switch on terminals 6 7 of the M4 terminal strip e An NA contact that closes to interrupt permission max 12 V 0 3A on terminals 8 9 of the M4 terminal strip PUMP 2 The
45. d maintenance procedure has been completed and press wv o The scheduled maintenance procedure will be updated the next deadline WinAmiFree management Software Pag 91 Amico Installation and User Manual 4 8 4 Odometer change and recalculation of the deadlines When a vehicle breaks an odometer or else if it goes over 100 000 kilometres it is necessary to inform the WinAmiFree software so that it can recalculate the deadlines as a function of the new odometer reading Push the Cambio conta km o contaore button Cambio contakm o ca O X automezzo 0001 AA 0O0BB 1VECO TED ALTOCA Chilometraggio attuale Anteporre il simbolo per le manutenzioni a scadenza in giorni Manutenzione Ultimi kmore segnati dal vecchio conta kmore ngagai Chilometri percorsi con il conta kmore guasto 000000 Kmore iniziali del nuovo conta kmore 0 nuovo oo0000 Enter the data requested e Kilometres or else hours read on the old odometer when it malfunctioned e Kilometres or else hours driven with the odometer when it malfunctioned e Kilometres or else hours read on the new odometer at the beginning and press vY The deadlines will be recalculated WinAmiFree management Software Pag 92 Amico Installation and User Manual 4 9 AmiDesktop Programming of the Amli Tags Programming of the AmiTags comes about by way of the Contactless AmiDesktop programmer optional and permits the change of the
46. d Refllel sssesestuntatdeia evt Poe ted d NS RAMSEY RI HER MIDI ranean 54 3005 7 RESTRICTED PARAMETERS MENU eot o iuda iki b ROREM V artius f aid 54 Sele Db 7 E SEtUP PUMP ice lil liebe 54 3 143 752 SEC UP GISTEN Zini faina ilari Senate 54 315 75 NUMEN HUMP 172 cumnsesieRdscRihadrhsoicDRdPR RS RR RII EROR AR ninni 54 9 1 5 7 4 NUMDerng Product 1 2 gela 55 35155 7 5 NUMBERING Company 172 v esversstiuoseE aaa er oou ice ea RD ME Reo nuce esee dades 55 3 1 5 7 0 Contact Dispenser unit 142 ectessuetetotuUoLIDIe RTL PME RA INR a UC R CEP DIES abi 55 3 1 5 7 7 Analogue Level Sensor Probe 1 2 eene 55 3 1 5 7 8 AmiBus Level Sensor Probe 1 2 _ rr 55 3 1 5 7 9 Calibration in the sensor probe siii elia 55 Slsb 7 T0 NUMBER SEU HELG 142 alles 55 S 15 ll SelfcalbralgonD DUITID 1 2 nsi ipusat eti Vu ERDERPEERS pta Eos etae ai arai rtu 56 3 1 5 7 12 Zero out operations IriemloFLy x susessexsosekut ooi oaa ia telai viale rasi pini 56 3 1 5 7 15 Mogli Machine COD ibra 56 3 2 SMS function from a cell phone to AMIcoONLINE iii 57 3 2 1 wISUOPCOITIHISIDdS seem assiubutetepre sq eme ada aaa 57 3 2 2 DescHbHohorl SMS GOMmIMaNGS we riale 57 3 2 2 L Requests tne stock In tlie CISUBED iiie oi do RR Ende sere losessEo aa 57 3 2 2 2 Registration of the Manager for reception of the automatic notifications 57 4 WinAmiFree management Software rrrrree uen n nana a
47. e second cistern Amico will modify the following characteristics e The menu functions pertaining to cistern 2 are enabled e Litres dispensed from pump 2 will be subtracted from cistern 2 3 1 5 7 3 Numbering pump 1 2 This allows the numbering to be attributed to each dispenser to be customised so as to diversify the count on a multiple plant system User Manual Pag 54 Amico Installation and User Manual The utilisation of this function is to be attributed to the possible connection of more than one Amico device to the same PC where the pump number is used for distinguishing the plant systems What is meant by numbering pump 1 is the number to be attributed to the pump connected to the M4 terminal strip of the Amico data card in out while the 2 pump is that which is connected to the M5 terminal strip The refuellings transferred to the PC will be associated with the pump indicated 3 1 5 7 4 Numbering Product 1 2 This allows the attribution of a filter on the type of product dispensed Setting the same number on the Vehicle AmiTag it is possible to dispense only the specified product For example setting 1 as the product number on the no 1 pump and 2 as the product number on pump 2 the AmiTags with product 1 limitation may dispense only on pump 1 3 1 5 7 5 Numbering Company 1 2 This allows the attribution of a company code belonging to a dispenser In the multiple plant systems it allows an AmiTag to refuel only from pumps
48. e the electronic partial litre counter for the last refuelling p Push the button to restart Amico These function buttons are active even during a refuelling allowing in this way the possibility to see the evolution of the situation in real time To carry out a refuelling follow the procedure described in the quick start 2 4 3 1 2 Optional requests during refuelling enabling The AmiTags that enable refuelling may be codified with additional functions apart from the standard by way of the AmiDesktop Contactless programmer and the WinAmiFree software These functions vary the Amico operations which customise the requests in function of the parameters read on the AmiTag inserted see 4 9 AmiDesktop Programming of the AmiTags 3 1 2 1 1 Request secret code PIN code The pin code allows the utilisation of the AmiTag only after having entered it It may be set both on the Vehicle AmiTag and on the Driver AmiTag On the vehicle Tag it is only usable if the vehicle is always used by the same driver The PIN code different from the driver code is not identifying 3 1 2 1 2 Request driver code The driver code is a secret code to be given to the drivers so as to be able to identify them during refuelling To activate the driver codes it is necessary to follow the procedure below Create the list of the driver codes on the AmiTag Program by way of the WinAmiFree software and the AmiDesktop Contactless programmer e Insert the
49. e the maximum quantity of litres to be dispensed as a function of the consumption set on the AmiTag see paragraph Block on Kilometres If the kilometres value entered is not within the range preset on the AmiTag there will In the event that the AmiTag is extracted before entering the kilometres there will appear on the display Installation Manual Pag 34 Amico Installation and User Manual To permit that checks on the kilometres driven be carried out in multiple plant systems Amico must be able to write the kilometres entered on the AmiTag itself In this case it is necessary to insert the AmiTag once again If there were no errors in the data entered or in the sequences requested the following message will appear on the display Carry out refuelling within 60 seconds After 60 seconds of inactivity Amico will disconnect the dispenser pump motor parameters that may be set during the configuration phase In the AOL module version AmicoOnLine the following message appears and the refuelling is immediately transferred to the AmicoOnLine server In the other versions the refuelling is memorised Verify on the Amico display the correspondence of the litres dispensed pushing the button If the data is downloaded manually insert the Download Data AmiTag and wait for the download of the tests For example PLEASE NOTE The manual download function on the Data Download AmiTag is disabled in the AOL version AmicoOnLine
50. eat the operation for all of the refuellings to be entered and press v OK External refuellings will be entered on pump number 99 to distinguish them from internal ones WinAmiFree management Software Pag 80 Amico Installation and User Manual 4 7 Cistern Stock Cistern stocks may be calculated in a rational manner by way of the difference between the litres dispensed and those supplied Or they may be calculated physically by way of the level sensor probe inserted into the cistern only with the AmicoOnLine version 4 7 1 Calculation of the stocks with the manual data download on the Data Download AmiTag To calculate the stock in a cistern from a manual download of the Data Download AmiTag Cisterne use the button in the main menu Cisterne BE al Giacenze in cisterna H CISTERHA BE 705106 Prodotto erogato Gasolio X ne The stock visualised in this screen is decreased at each data download for a value that corresponds to the sum of the litres dispensed To change the value of the cistern click on the button and make the change ATTENTION Before making a correction of the cistern value download the data from the Amico control unit so that eventual refuellings in memory can be subtracted from the correction made Cisterns are automatically created for each pump If there is more than one pump connected to a cistern it is necessary to configure the program to deduct product from only one st
51. ecret code request for the PIN code to be entered in the data box on the right If the operator does not have this code s he cannot use the AmiTag Driver Code to be used as an alternative to function 6 Requests that the driver enter one of the 99 codes codified on the AmiTag program to be identified Job order number request this is requested upon the operation of entering the job code number or cost centre to which the refuelling is to be attributed Maximum litres to be dispensed in a refuelling predetermines a refuelling limit to a maximum number of litres to be dispensed during a refuelling Keyboard pre selection only for compatibility with previous systems Refuelling block in function of kilometres this blocks refuelling if the kilometres entered are not within the parameters indicated in point 2 and predetermines the refuelling as a function of the consumption average Type of AmiTag the VEHICLE AmiTag is used for the identification of the vehicle that is being refuelled allowing in this way a control of consumption Card pass status may be OK for a valid AmiTag or DISABLED if it has been inserted in the control unit after having been disabled Km since last refuelling this is the entering of the odometer reading or of the vehicle counter entered by the driver at the last refuelling carried out A zero value in this field indicates a new AmiTag or unblocked from the kilometre check until the next refuelling Maximum au
52. ento 522503 068362 166070 150410 3 Totali erogati per Pompa Pompa Totale litri 0001 0002786 82 4 4 6 5 Counter report of litres dispensed The load and unload report allows the reconstruction of the pump s counter at the end of the day It is necessary to set the counter value at 23 59 of the previous day for the period chosen and the theoretical value at 23 59 will be calculated for each day Carico e scarico Push the button WinAmiFree management Software Pag 77 Amico Installation and User Manual WinAmiFree Limita o Preseleziona Caratteri ricevuti 0 i IErrari nel CK a Impostazione date Y mercoled 10 Archivio Storico 1896 luglio 1385 Calcolo dei totalizzatori giornalieri Totalizzatore alle 23 59 del31 12 2008 Calcola tot giornalieri della pompa n jAmiDeskCL X ims Enter the counter at 23 59 of the day previous to the beginning of the period Enter the pump number and push v Report Window 01 07 1996 02 07 1996 03 07 1996 04 07 1996 05 07 1996 06 07 1996 08 07 1996 09 07 1996 10 07 1996 Totali erogati per Pompa Pompa Totale litri 0007 0019740 08 WinAmiFree management Software 2861 Giorno Totale litri erogati 2786 1718 2339 2233 2112 1404 1656 2607 82 14 2b sb 38 24 46 88 02 WinAmFree r 01 11 10 c 2001 2009 by fabrizio binotti com
53. eration for making phase neutral the Amico device operational Absorption min 0 1 A With all of the options present at rest BEEN 1A 3 5 A With the TTL printer operational e A M Line frequency 50 60Hz eee Fuses F 0 12 24 F 0 24 F3 F4 IN 220 F5 OUT 220 Maximum altitude Operational temperature 209 C 40 C without printer option 10 C 40 C with printer option Operational relative humidity 30 to 90 torage temperature 25 C 60 C o _ torage relative humidity 10 to 90 Dimensions max appendix A Container CA 01 L370 x H 290 x D P370 With protective hood Container CA 02 dum P370 With protective hood Container CA 03 le x H 450 x D Container CA 04 Container CA 05 L 241 x H 241 x D 90 L 245 x H 465 x D 135 L 410 x H 340 x D 360 Attachments Pag 112 Amico Installation and User Manual Weight Considering all of the options included Container CA 01 4 kg Container CA 02 7 kg Container CA 03 3 kg Container CA 04 4 kg Container CA 05 8 kg E Protection grade IP55 D Conservation time of dispensing 10 years Dg Conservation time of momentary 10 years data in case of power failure dispensing Conservation time date and 1 year Average A span of clock 6 years Connector Terminal X1 Connection with external line NEUTRAL Connection with external line PHASE Connection for Grounding Connect
54. error Allows the kilometres at the last refuelling of a vehicle to be zeroed out so as to allow it to be refuelled 4 Command report allows the visualisation of the list of the commands transmitted and the status of their reception Their reception status may be e INLINE The server is waiting for a refuelling to be made to transmit the command to Amico e RECEIVED Amico received the command e CANCELLED Amico cancelled the reception of the command It must be retransmitted WinAmiFree management Software Pag 100 Amico Installation and User Manual WinAmiFree a T o Semen n reu s Caratteri ricevuti Errori nel EK CHIPDRIVE 3 4 5 6 7 1 Machine code is the number that identifies the Amico control unit or a group of Amico equipment on which the same AmiTag may refuel It identifies the user It must be communicated when requesting new AmiTags 2 Card Number in the Data Download AmiTag it must always be numbered 1 3 Button to read the AmiTag parameters 4 Button to write changes on the AmiTag 5 Button to write the AmiTag and increase by one the card number and the vehicle number This is used when several AmiTags are to be written in succession 6 Button to reload the parameters of a card that was saved 7 Button to save the parameters of this card so as to be able to recall them 8 Card type The Program AmiTag is used to program Amico 9 Card pass status May be OK for a valid AmiTa
55. ew vehicle click on the button pug A new vehicle identification number will be entered that is higher than the last one entered By convention if the first character in the description is an asterisk the software calculates consumption of the vehicle at litres hour instead of km litre Anagrafica Automezzi Nu Targa e descrizione iniziale per il conta ore AA 000 BB IVECO 190 MULETTO N 1 gt Nuovo fff Cancella S Elenca kJ IMPORTA X Esci The vehicles may be combined into affiliation groups In the archive it will be possible to filter the refuellings for one of the groups inserted To enter an affiliation group click on the Affiliation Group data entry box of a vehicle then enter all of the affiliation groups WinAmiFree management Software Pag 63 Amico Installation and User Manual Gruppi bad AUTOVETTURE AUTOCARRI MULETTI gt Nuovo Tm Cancella Elenca LJ IMPORTA X Esci The button allows the Windows Report to be opened with the list of the drivers entered so as to allow its printing or its copying onto the clipboard Report Window DX WinAmiFree r 01 11 10 c 2001 2009 by fabrizio binotti com Elenco degli autisti in archivio 2 0001 Binotti Fabrizio 0002 Gabetta Massimiliano WinAmiFree management Software Pag 64 Amico Installation and User Manual 4 3 3 Products in the cisterns In the consumption averages analysis of the litres dispensed it is neces
56. g or DISABLED if it has been inserted in the control unit after having been disabled 10 Random codes Generation it generates random codes for driver identification At each click of this button the codes are changed 11 Recover predefined codes recovers default driver codes 12 Display and print codes Displays driver codes in the windows report List driver codes contains the list of codes the drivers must enter for their identification The driver number in the right hand column must correspond to the name and surname of the driver in the driver identification list the driver code in the right hand column and the code that the driver must enter in the Amico control unit so as to be identified The driver codes are requested by the Request driver code function on the Vehicle AmiTag WinAmiFree management Software Pag 101 Amico Installation and User Manual 5 Attachments Attachments Pag 102 Amico Installation and User Manual 5 1 CE conformity BINOTTI di Fabrizio Binotti amp Via GCavour 58 90 27030 Sartirana L Pavia ttalia Tal 0384 E00737 Fax GM BOOTIE Biip www binotti com e mail infagghinatti cem DICHIARAZIONE DI CONFORMITA La sottoscritta Binotti sno con sede in via Cavour 8 a Sartirana Lomellina Py dichiara che prodotta Amico 2002 In funzione al rapporte di prova EMC conforme alle seguenti norme CEI EN 50081 1 1992 Emissione CEI EN 50082 1 1992 immuni
57. gement Software Pag 66 Amico Installation and User Manual 4 4 Report window All of the reports requested of the WinAmiFree program will be visualised in the report windows in a text form The reports may be printed or copied to the clipboard in Windows Report Window WinAmiFree r 01 11 10 c 2001 2009 by fabrizio binotti com Elenco degli autisti in archivio 2 0001 Binotti Fabrizio 0002 Gabetta Massimiliano BS To print the report click on the button and select the printer To copy the report into a word processor or an e mail click the button WinAmiFree Il contenuto della finestra WinAmiReport stato copiato nella clipboard Per copiarla nel programma desiderato premere CTRL V oppure selezionare Modifica gt Incolla Open the program where the report is to be copied and push ctrl V or else select the PASTE function Ex in Word WinAmiFree management Software Pag 67 Amico Installation and User Manual 3i Documento3 Microsoft Word DX le Modifica Visualizza Inserisci Formato Strumenti Tabella Finestra Digitare una domanda X E Annulla digitazione CTRL Z amp MoOR E 100 o Es 7 Commentifinai Taglia CTRL4X H Dn a ELM 7 1 8 1 9 1 10 1 11 1 12 1 B 1 14 1 15 1 16 i ar ___ Appunti di Office E Incolla CTRL V Seleziona tutto CTRL 5 Tn Trova CTRL MAIUSC T 2001 2009 by fabrizio amp binotti com E
58. hat the product is non standard Avoid that Amico be exposed to water spray other than rain PP kOpening the panel may be undertaken only after having disconnected the electrical power from the equipment An electrical discharge could cause serious harm or even death P Opening the Amico panel may be undertaken only by qualified personnel An electrical discharge could cause serious harm or even death Installation Manual Pag 13 Amico Installation and User Manual 2 2 Installation of the Amico Control Unit 2 2 1 System Components w 0 1 2 3 4 NO C0000 2000 lear Amico Control Unit detail Figure 5 Sunshade wings Slot for AmiTag card 20 x 4 display KR WU N HL Alphanumeric keypad Inside of the Amico internal control unit electrical panel there are Installation Manual Pag 14 Amico Installation and User Manual The Amico I O electronic data card for the electrical powering of the Amico control unit and the interface with the pump units e The Amico 2005r2 0 electronic data card with retro integrated display e The micro modem for PC connection optional e The GPRS AmicoOnLine modem AOL for internet connections and to send SMS messages optional e The AmiTag reader LALETA EEES ESSEE EEE Inside of the control unit Figure 6 Amico 2005 data card CPU The AmiTag reader AmiBus AmicoOnLine module or micro modem for PC connection I O data card Duk wn Ins
59. he AmicoOnLine server In the AmicoOnLine versions the stock is calculated by the AmicoOnLine server and transmitted to the WinAmiFree software and to Amico To visualise the stock click t y Giacenze in cisterna on Amcontine sa and then afterward on the button AmicoOnLine bd Codice Amico E 00 Config QD Amico Aggiornamento giacenza er ONLINE La giacenza CALCOLATA e quella logica viene aggiornata decrementato T il valore attuale ad ogni riformimento effettuata Per aggiornare il carica fatto in cisterna inserire valori e premere APPORTO i valor verranno sommati alle giacenze attuali Per fare una correzione al valori proposti inserire le giacenze corrette e cliccare STORNO La giacenza da SONDA e quella calcolata dalla sonda di livello CISTERNA listerna collegata alla pompa 01 TACITO dacenzs 8 Aggiornata al 16 02 2009 11 33 da sond mE c eee 22 Lx FE SULLA CISTERNA Numero della prima collegata alla cisterna 01 Valore analogici ah velo se plesente DOO i Nes 5 Current stock calculated by the AmicoOnLine server 2 Button to record an addition to the cistern The litres added will be summed to those currently present Mask for the entry of litres to add or to transfer 4 Button to record a correction of the cistern The litres added will substitute the current stock Stock calculated by the level sensor probe 00000 if not present 6 Select the cistern One cistern is
60. igation are the following Ok e This button D is the confirmation button It corresponds to accepting the message visualised in the display confirming the data set and the access to the menu functions NO e This button No is the negation button It corresponds to the wish to not execute that which is proposed on the display During data entry it corresponds to the zeroing out of the same so as to be able to modify them e This button locates the navigation in the first menu STOCK MENU User Manual Pag 47 Amico Installation and User Manual This button allows the exit from navigation e The menu headings are in Upper case letters the functions in lower case e To enter into a menu or a function push this sutton OB No e To skip to the next menu or to the next function push No Example To activate the function Set Date and Time in the CUSTOM PARAMETERS MENU 1 Insert the program AmiTag and extract it when requested NO 2 Push No 5 times to go to the CUSTOM PARAMETERS MENU 3 Push to go to the first function 4 Push to activate the function 5 Enter the year and push 6 Enter the month and push 7 Enter the day and push 8 Enter the hour and push 2 9 Enter the minutes and push p 10 Push the button to exit from the program card User Manual Pag 48 Amico Installation and User Manual CISTERN STOCK MENU MENU DISAB TAG VEHICLE M
61. ination of a maintenance procedure Ww ON A Ui d U N AmiTag number and description of vehicle selected Im e Actual kilometres or hours on the vehicle updated by the acquisition of refuellings Im Im Filter to hide visualisation of scheduled maintenance procedures not yet expired Im N Filter to hide scheduled maintenance procedures of vehicles with incoherent kilometrage Im CJ Filter to view only scheduled maintenance procedures of vehicle selected m N Filter to anticipate scheduled kilometric maintenance procedures deadlines m Ul Filter to anticipate scheduled kilometric maintenance procedures on a set date m CO Button to record scheduled maintenance procedures carried out m N Button to create a report of scheduled maintenance procedures m CO Button to create a report of the history of scheduled maintenance procedures saved Im O Button to recalculate deadlines after the change of an odometer 4 8 2 Verification of expired scheduled maintenance procedures Upon each acquisition of data the WinAmiFree updates the current odometer readings of the vehicles and checks if there are expired scheduled maintenance procedures In the main screen it is possible to visualise the updated situation Clicking on the filters it is possible to hide those that are not expired and those with incoherent odometer readings Scheduled maintenance procedures are visualised with an X after the desc
62. ion for Grounding NEUTRAL output motor connection MAX load 10 A PHASE output motor connection MAX load 10 A OUT terminal not used maintained only for compatibility 1 12 V AC Connection 12 0 12 with Amico 2000 R1 0 data card Max load 3 A 2 0VAC Connection 0 24 with Amico 2000 R1 0 data card Max load 3 A 3 2 12V AC 4 0 VAC 5 24 V AC Output terminals M4 PUMP1 Attachments Pag 113 Amico Installation and User Manual OV Clean contacts normally open max 1A cos 1 max 30 V DC Nozzle or 24 V AC 12V DC Max section of cables 2 5 mm OV Digital counter input pump 1 10mA 24 V DC Ch1 pulser Out 24 V AC Out 24 V AC Out N O Out N O 1 2 3 4 5 6 7 8 9 Output terminals M5 PUMP 2 OV Clean contacts normally open max 1A cos 1 max 30 V DC Nozzle or 24 V AC 12V DC Max section of cables 2 5 mm OV Digital counter input pump 2 10mA 24 V DC Ch2 pulser Out 24 V AC Out 24 V AC Out N O Out N O 1 2 3 4 5 6 7 8 9 Ed OPTION PRINTER TTL 24 column Average operational time of About 1 0 million receipts 10 lines per receipt printer mechanism Average operational time of About 1 5 million receipts 35 mm printed per receipt printer head mechanism Plain paper 57 mm diam 50 EPSON ERC 09 Printer paper Printer ribbon COMMAND PUMP COUNTER POWER SUPPLY OPTION Phase phase motor power supply command Terminal tightening torque 0 8m Attachments Pag 114
63. la pompa n E me el Ripeti per ogni n pompa amp AmiDeskCL Demonstrative data has been inserted in the program so as to demonstrate its functions Select the year 1995 to use the test data In the DA lines A It is necessary to enter the time period in which one is interested in seeing the refuellings Some more often used periods have been preset in the first bar Otherwise it is necessary to manually select the start date and end date The historical archive reports may be requested by averages grouped by vehicle or else chronologically grouped in time order Click averages to see the consumption report remember to set the initial date at the year 1995 to see these test data Scroll down the bar until reaching the vehicle 523 Installation Manual Pag 37 Amico Installation and User Manual ox Automezzo 0523 Data e ora Autista Km Litri Percorsi Km L F Nome autista O1 07 1996 17 48 0014 35025 O269 06 DI 04071996 04 31 0001 36083 0332 35 1058 3 18 Ol 0570771996 18 10 o001 Da 7050 Q342 08 DI Q2 82 l Os 071996 07 28 0001 Da felS O250 08 Deb O2 6 01 0970771996 16 41 OO01 38579 Q311 36 ee 1 O2 6 Cl 10071996 18 36 0001 039235 Dagr 4 0656 02 65 l 127 0771996 17 26 0001 40549 0326 46 1114 O2 86 Dl 157 0771996 16 23 0001 40920 DODD BO 0571 DI 1570771996 16 25 0001 40920 0182 32 A AAA 03 11 O1 1601996 15 41 0001 041574 0233 04 654 O2 00 Dl 17 07 1996 16 42 0001 42141 DSL i D567 3 12 01
64. lation and User Manual 4 9 2 Driver AmiTag WinAmiFree e I zo 3 re Richie l rie 6 es ee Caratteri ncevutr O Errori nel CE D CHIFDRINE T a 3 10 11 1 Machine code is the number that identifies the Amico control unit or a group of Amico equipment on which the same AmiTag may refuel It identifies the user It must be communicated when requesting new AmiTags 2 Card number is the number that identifies the AmiTag and is used exclusively for disabling it in case of its being lost 3 Driver number this is the number with which the driver is identified inside of the WinAmiFree software In the driver identification list the number is associated with the name and surname of the driver 4 Secret code request for the PIN code to be entered in the data box on the right If the operator does not have this code s he cannot use the AmiTag 5 Request vehicle card This Driver AmiTag must be utilised together with a Vehicle AmiTag to enable refuelling On the Vehicle AmiTag the instruction request driver card must have come up 6 Request Vehicle number The entering of the vehicle number corresponds to the insertion of a Vehicle AmiTag with that number Being an entry it is not possible to set the functions present on the Vehicle AmiTag The only preset function is the kilometre request Button to read the AmiTag parameters Button to write changes on the AmiTag WinAmiFree management Software P
65. lenco degli autisti in archivio 2 0001 Binotti Fabrizio 0002 Gabetta Massimiliano 1 1 A4 7cm Ri8 Coll REG REV EST SSC Paliano Ialia WinAmiFree management Software Pag 68 Amico Installation and User Manual 4 5 Download refuelling data The WinAmiFree software acquires the refuellings of fuel from the Amico control units on the PC for the elaboration and writing of the report As a function of the type of connection with the data acquisition equipment it must be carried out with appropriate buttons 4 5 1 Functions for data download from the Data Download AmiTag For data download from a Data Download AmiTag previously inserted into the Amico control unit bring the Data Download AmiTag close to the AmiDesktop Contactless and click the button Scarico dati dalla carta Ultimi Dati Acquisiti The data downloaded may be immediately verified with the button Report Window WinAmiFree r 01 11 10 c 2001 2009 by fabrizio binotti com Ultimi dati acquisiti Data e ora Mezzo Autista Km o Ore Litri Pompa 05 11 2008 11 34 0001 0000 000234 0000 49 01 AA 000 BB IVECO 190 Totali erogati per automezzo Carta Totale litri Km a ultimo rifornimento 0001 000 49 000234 AA 000 BB IVECO 190 Totali erogati per Pompa Pompa Totale litri 0001 0000000 49 A Data Download AmiTag may contain no more than 100 refuellings If there were to be more in the Amico memory after the download the following message will appe
66. m the stop of the automatic pump hand dispenser to the beginning of the top up If within this time in seconds the top up does not begin Amico considers the refuelling finished and disconnects the dispenser pump It is set at 20 seconds oR Enter the number of seconds and press 3 1 5 7 RESTRICTED PARAMETERS MENU The Restricted Parameters Menu is to be used exclusively by the installer It contains parameters for the connection of Amico to the dispenser pumps Its functions are protected by an initial password so as to avoid that by accident the fuel depot manager may compromise the system 63 Enter installer password and press 3 1 5 7 1 Setup Pump 2 This allows the management of a second dispenser pump at the same time as the first Setting up the second dispenser pump Amico will modify the following characteristics e Once the pass card has been inserted and the refuelling has been enabled INSERT AMITAG will appear again on the display so as to allow the enabling of the second dispenser pump e The menu functions pertaining to pump 2 are enabled Before refuelling the selection of the number of the pump where one is to refuel is requested if not specified in the AmiTag limitations e If not specified in the function Set up cistern 2 the litres dispensed from pump 2 are subtracted from the stock in cistern 1 3 1 5 7 2 Set up Cistern 2 Allows the management of a second cistern connected to pump 2 Setting up th
67. ment Inserimento di una n OIX Automezzo 0001 44 000 BB IVECO 190 AUTOCA Chilometraggio attuale 000001 Anteporre il simbolo per le manutenzioni a scadenza in giorni Bollo Manutenzione Data prossima scadenza giovedi 1 maggio 2003 7 Manutenzione da effettuare ogni 365 giorni Press and confirm the changes x Humero automezzo e descrizione Lj 000 44 000 BB WECO 130 9 LS Chilometri o ore attuali 120000 10 De Manutenzioni Auto Scadenza Ogni Tipo scadenza a giorni Ix 10001 01 06 09 000365 Bollo 0001 030000Cambio Olio Motore Nascondi manutenzioni non scadute 1 Nascondi manutenzioni con km errati 7 T 2 Solo manutenzioni del mezzo seleziona 13 m Anticipa le manutenzioni di km 00000 3 14 Anticipa le manutenzioni di gio 15 4 5 Rapporto delle manutenzioni 1 17 Cambio conta km o contaore 19 iif Elimina X Esci WinAmiFree management Software Pag 89 Amico Installation and User Manual Vehicle AmiTag number Next maintenance deadline in Km hours or at an established date Frequency of the Maintenance deadlines in Km hours or days Maintenance procedure description Expired X Kilometre error or else not expired empty Button for the entry of a new maintenance procedure Button for the modification of the parameters of a maintenance procedure Button for the elim
68. n to read the AmiTag parameters Button to write changes on the AmiTag Button to write the AmiTag and increase by one the card number and the vehicle number This is used when several AmiTags are to be written in succession Button to reload the parameters of a card that was saved Button to save the parameters of this card so as to be able to recall them Card Type the Download Data AmiTag is used to transfer the refuelling data Card pass status may be OK for a valid AmiTag or DISABLED if it has been inserted in the control unit after having been disabled Pump counter 1 indicates the electronic counter for pump 1 in the Amico display at the moment of the data download Pump Counter 2 indicates the electronic counter for pump 2 in the Amico display at the moment of the data download Stock 2 indicates the stock in the Amico display at the moment of the data download Exit exits the AmiTag programming 4 9 4 Program AmiTag The Program AmiTag is used for the programming of the Amico operational parameters and for the transferral of driver codes from the PC to the Amico control unit WinAmiFree management Software Pag 98 Amico Installation and User Manual 4 9 5 Command transmission to the Amico control unit For the Amico versions connected directly to the PC via cable or by way of the AmicoOnLine server the WinAmiFree software permits the transmission of commands for remote management 4 9 5 1 Command tra
69. naged by a proxy server Generally the setting of the proxy is imported automatically If it were to become necessary to set them manually perform the following operations o Enter the code 021070 in the data entry box Config o Enter the access data requested 2 3 4 3 Enabling direct connection via cable Amico micro modem Double click the WinAmiFree icon to execute the program Therefore click the Acquire Data button The detection of the type of connection is requested Press OK You are asked if you want to try a TCP network connection Press NO The search on the serial port is requested Press OK The PC begins its search on the communications ports Once Amico is detected a confirmation message appears Installation Manual Pag 31 Amico Installation and User Manual 2 4 Quick Start Up To verify the proper operation of the system follow the instructions below for more detailed information refer to the User Manual section 2 4 1 1 First Refuelling Get the Vehicle No 1 AmiTag and the Data Download AmiTag if a manual data download is intended Turn on Amico by shifting the switch inside of the control unit towards the left 3 beeps indicate the system reset On the display the firmware version message appears for a few seconds and afterwards the message Insert an AmiTag into the slot The Amico control unit will read its characteristics and will ask the operator to follow the procedure set out by its paramete
70. nd cistern 3 1 5 1 1 Correct Stock Cistern 1 2 This allows the setting of the quantity of a product in a cistern The stock will be reduced by the quantity of litres dispensed at each refuelling Ok Enter the number of litres in cistern 1 and push OK The function is not active if the AOL AmicoOnLine module or if the level sensor probe is present Note the same operation may be made by the Personal Computer in the equipment connected by cable or to AmicoOnLine 3 1 5 1 2 Start Calibration Cistern 1 2 This function is active only if the level sensor probe without internal calibration is present in the Amico with AOL module AmicoOnLine For additional information on how to initiate a calibration see How to initiate a self calibration This allows the setting of the quantity of product in a cistern and to initiate the self calibration of the level probe sensor Ok Enter the number of litres in stock in the cistern and push D Amico connects to the AmicoOnLine server and transmits the command to initiate calibration In case of error in the connection repeat the procedure 3 1 5 1 3 Set minimum reserve in Cistern 1 2 This allows the setting of an alarm level for the stock in the cistern beyond which the operator will be notified at the moment of refuelling with a message on the Amico display User Manual Pag 50 Amico Installation and User Manual Enter the number of litres at which point a notification will be a
71. net only for Amico with Installation Manual Pag 30 Amico Installation and User Manual AOL module Double click the WinAmiFree icon to execute the program and click the AmicoOnLine button If the AmiDesktop has already been configured for AmiTag programming the AmicoOnLine software will automatically import the machine code otherwise 2 AmiTag Program codes will be requested the machine code and the unlock code Enter the printed codes and the software will be configured To verify the operation of the internet connection it is necessary to have carried out a refuelling using one of the AmiTags provided and it is necessary that Amico transmit this to the AmicoOnLine server To acquire data on the PC click on the Acquisition Data button All of the data not yet downloaded will be transferred to the WinAmiFree software In the event that the call was to not go through the following points need to be verified e Is the Internet connection active Verify by way of Internet Explorer if the Internet connection is active entering the site address http www amico on line it in the address bar e Is Windows firewall active and blocking the program Technically the data is transferred to the program by way of an HTTP call on the 80 port by the AmiOnLine exe program to the server www amico on line it It might be necessary to inform the firewall that the program is authorised to carry out these calls e Is the internet connection ma
72. nita che include percorsi locali e supporti nmowibili Il miglior driver disponibile verr installato Cerca nei supporti rimovibili unit floppy CO ROM Includi il seguente percorso nella ricerca C emicoSdriverAD Lwinzk xp At Non effettuare la ricerca La scelta del driver da installare verr effettuata manualmente Scegliere questa opzione per selezionare da un elenco il driwer di periferica driver contenuto nell elenco potrebbe non essere quello pi aggiornato per la periferica Push Browse Sfoglia per cartelle Selezionare la cartella contenente i driver per l hardware Ef Desktop ES i3 Documenti El W Risorse del computer ES H Floppy da 3 5 pollici A Gat Disco locale Cs E t 98100f80d284491fc9 E amico 3 D driverADC c winzk xp DI wings Per visualizzare le sottocartelle Fare clic sul segno pi Select the win2kxp folder as in the illustration in the program installation folder and push OK Installation Manual Pag 28 Amico Installation and User Manual Installazione guidata nuovo hardware Attendere Hicerca in corso China W izion RF Reader USE C6600 g Installazione hardware AN Il software che si sta installanda per l hardware China VYizion RF Readel US6 CvBBDL non ha superato il testing del programma Windows Logo che consente di verificarne la compatibilit con Windows xP Informazioni sul testing L installazi
73. nnua 58 4 1 JIntroductlOTiizsseixesssses bha PEE EK ERR PROKE OLIO icia 59 42 MaN Sree MEM 60 2 9 TGSHCIRICALIOINISES weree corsa vetu ded EEUU tee fexus ew nie eee beeete vata ina ad vUPE UU De IUE 61 2 3 1 Driver IdentulicatloD EISE vere E x as daa re RERa 1 E CP vam o DUET E C fa ORE Pci CER dca 61 2 3 2 wehlcleddentficatlonlilSE sco RESERVE Aa EC EUER pains arena REESE 62 4 9 9 PFOdUELS Inthe CIste rasta lalla eme 65 did REeport WindoW RTT E ULT 67 445 Bownldbad retuellino dalte nabla 69 4 5 1 Functions for data download from the Data Download AmiTag 69 4 5 2 Functions for data download from a direct connection by way of cable 70 4 5 3 Functions for the data download from the AmicoOnLine server 71 2 6 AFGNIVE OFTERUGIIMOS iran 73 2 6 1 Refuelling visdalisatior TIIEel Sector xa Ne br ad uo ve hans awa EAR ERROR RSS 73 4 5 2 Average consumption reportas grae dos olo e tuendo e etas gu cane wea udo Da Cose ames La 75 4 6 3 Data modification and Km COFFectloln issius es vet p eae ti rad M e onc et ERR ERE RC S 76 4 64 ChronologiCal ReDOLE uidet eeoe leale 77 4 6 5 Counter report of litres dISDerised iterat dst desti tad e ames ei WEE aerate 77 4 6 6 External refuelllfigSs iis Li Ero ER C REC ER E EUR EAQUE ER UE TCR TTEVER EE KEDERXEX RA AR CHREXTERYR 79 a RP AME S i IESU m m PHm 81 4
74. nsmission in the direct cable connection In the direct cable connection it is possible to transmit certain commands without having to work the Amico keyboard in the AmiTag program menus WinAmiFree Ami DeskTop Caratteri ricevuti 0 Errori nel CE O amp mibeskCL 1 Correct date and time transmits the PC clock to the Amico control unit to correct the internal clock 2 Disable or enable cards allows the blocking of an AmiTag from refuelling enter the card number not the vehicle number to be disabled 3 Unlock kilometre error Allows the kilometres at the last refuelling of a vehicle to be zeroed out so as to allow it to be refuelled 4 9 5 2 Command transmission to the AmicoOnLine server In the connection by way of the AmicoOnLine server it is possible to transmit certain commands without having to work the Amico keyboard in the AmiTag program menus The WinAmiFree management Software Pag 99 Amico Installation and User Manual commands transmitted will be memorised by the AmicoOnLine server and transmitted to the Amico at the end of the next refuelling AmicoOnLine x Codice Amico 299 00 Config Amico E E ONLINE 1 Correct date and time transmits the AmicoOnLine server date and time to the Amico control unit to correct the internal clock 2 Disable AmiTags allows the blocking of an AmiTag from refuelling enter the card number not the vehicle number to be disabled 3 Unlock kilometre
75. nually manage the selection of the connection use the button WinAmiFree management Software Pag 70 Amico Installation and User Manual Chiamata tramite modem Descrizione dell impianto Numero da chiamare Amico LAN TCP 192 165 001 00 1001 Amico sulla porta cam 1 COM Amico sulla porta com 2 COM J Nuovo Tif Cancella lt salva 5 Scarico a Chiama X Esci For remote connections it is possible to insert a telephone number to make a call by way of a telephone modem this is for compatibility with old systems or else it is possible to insert the name of the serial port with which the connection is to be made Ex COM1 COM2 etc or else the TCP address of Amico if connected by way of an ethernet 232 adapter Ex TCP 192 168 001 001 1001 4 5 3 Functions for the data download from the AmicoOnLine server For data acquisition from the Amico with AOL module from the AmicoOnLine server the AmiOnLine software needs to be used This may be carried out by clicking on the AmicoOnLine button WinAmiFree management Software Pag 71 Amico Installation and User Manual AmicoOnLine ICO Codice Amico 2000 conio F AE AE ONLINE Click on the oes a EUH WES esl All of the refuellings not yet downloaded by Amico belonging to the Amico code visualised will be acquired WinAmiFree management Software Pag 72 Amico Installation and User Manual 4 6 Archive of refuelling
76. o Installation and User Manual 3 User Manual User Manual Pag 41 Amico Installation and User Manual 3 1 Amico control unit use 3 1 1 Turning on and operator panel description To access the Amico control unit turn the automatic manual switch to automatic Once the Amico electronics are turned on for several seconds the following message will appear on the display In the first line the Amico software version will be visualised firmware This manual refers to the version indicated at the beginning of this manual The machine code identifies the user code All of the Amico systems with this code may enable refuelling with an AmiTag programmed with the same code The pump number identifies the numbering of the dispenser pump inside of a multiple plant system In single plant systems the pump number is 1 Set Litres are the number of impulses from the impulse generator needed to make a litre of fuel This parameter is configured in the installation of the plant system Several seconds after turn on the following message will appear on the display In this moment Amico has excluded the controlled pumps and in order to carry out refuelling an AmiTag must be inserted into the reader slot Push the button to visualise the electronic dispenser counters User Manual Pag 42 Amico Installation and User Manual Push the button to visualise the updated stock values in the cistern tanks Push the button to visualis
77. o change kilometres entered erroneously by the operator If the exact kilometrage of the vehicle at the moment of the refuelling is not known set the same kilometres as those given in the previous refuelling In this manner the average will be calculated by summing the average of the two refuellings To change other data from the refuellings click on the button To delete a refuelling selected click on the button Ti WinAmiFree management Software Pag 76 Amico Installation and User Manual 4 6 4 Chronological Report This is the report that allows the listing of the refuellings carried out ordered by date and time Set the filters that are desired and click on the button Cronologico s Report Window a m WinAmiFree r 01 11 10 c 2001 2009 by fabrizio binotti com Storico dati acquisiti dal 01 07 1996 al01 07 1996 sulla pompal Cautomezzi dal n 0500 al n 0530 1 Filters set before report creation 1 2 Refuellings 01 07 1996 03 17 0524 0001 455462 0350 10 I 01 07 E Total dispensed per 2 01 07 1996 04 56 0160 10 1 01 07 1996 05 22 0110 22 vehicle 01 07 1996 14 19 0037 46 01 07 1996 16 29 0403 08 01 07 1996 16 40 0110 06 4 Total dispensed per 01 07 1996 16 45 0240 02 01 07 1996 17 09 0173 18 pump 01 07 1996 17 40 0150 00 01 07 1996 17 48 0269 06 01 07 1996 19 00 0250 16 01 07 1996 19 08 0167 02 01 07 1996 20 05 105954 0176 02 Totali erogati per automezzo Totale litri Km a ultimo rifornim
78. o create a new combination WinAmiFree management Software Pag 87 Amico Installation and User Manual Inserimento di una n OIX automezzo J001 A 00068 WECO 190 AUTOCA v Chilometraggio attuale O00001 Anteporre il simbolo per le manutenzioni a scadenza in giorni Manutenzione Ei Manutenzione da effettuare ogni O00000 Prossima scadenza al km o ore UOOQUO km o ore Select the vehicle on which the maintenance is to be entered and name the maintenance or else choose one from the list Each new maintenance procedure entered will be saved to the list Enter the number of kilometres that must be driven for each maintenance procedure and the kilometre reading from the vehicle the last time that the procedure was performed TN Led nserimento di una n Automezzo 0001 44 00088 IVECO 190 AUTOCA Chilometraggio attuale 00000 Anteporre il simbolo per le manutenzioni a scadenza in giorni Cambio Olio Motore Manutenzione da effettuare ogni DO Prossima scadenza al km o ore 100000 km o ore Press and confirm the changes WinAmiFree management Software Pag 88 Amico Installation and User Manual Confirm the entry of a new maintenance procedure this time with a time expiry Enter the maintenance procedure with an initial asterisk By convention this indicates to the program that this has to do with a procedure that has an expiry in days ex registration pay
79. ock For example if pump 2 is still connected to cistern 1 click on the amp button to enter into the configuration change select pump 2 and associate it to cistern 1 WinAmiFree management Software Pag 81 Amico Installation and User Manual Cisterne Ej NH POMPA H CISTERNA Press v to save the configuration 4 7 2 Stock calculation with direct connection via cable In the cable connection stock is calculated by Amico and reassembled in the office when Giacenza in cisterna requested To visualise the stock click on the button WinAmiFree management Software Pag 82 Amico Installation and User Manual WinAmiFree ILU dr mr ur mr ur m Aggiornamento giacenza AmicoOnLine 2 3 km errati 4 p Caratteri ei rG Errori nel CK D AmiD eskCL Stock calculated by Amico Mask for the insertion of changes in the cistern Button to record an addition to the cistern The litres added will be summed to those currently present 4 Button to record a transfer in the cistern The litres added will substitute the current stock To enter a replenishment of the cistern enter the litres to be added to the stock in the data entry window and click the IM button To correct the current stock enter the current litres in stock in the data entry window and click the button WinAmiFree management Software Pag 83 Amico Installation and User Manual 4 7 3 Stock calculation by way of t
80. ome about by way of the use of a second driver type AmiTag to be used together with a vehicle type otherwise through the use of a secret identification code driver code The programming of the AmiTag and the creation of driver codes come about by way of the WinAmiFree software and the AmiDesktop Contactless programmer see par 2 3 3 The most frequent programs for the AmiTags are the following e Vehicle AmiTag request Km when one driver always uses the same vehicle e Vehicle AmiTag Km request driver code when it is preferred that the driver also be identified max 100 drivers e Vehicle AmiTag Km request Driver AmiTag when it is necessary to identify the driver in a secure manner e Driver AmiTag and enter the vehicle code number when it is not possible to utilise the Vehicle AmiTag ex drums street sweepers It is also possible to program several refuelling limitations on the AmiTags for the pump numbers for the type of product for affiliation group for predicted consumption levels as a function of kilometres driven etc For further details see the paragraph on AmiDesktop 2 3 1 6 Configuration of the level probe sensor A level probe sensor to provide correct values must be configured in function of the cistern tank in which it is used The dimensions the shape eventual inclination angles of the tank require that in order to obtain significant values the level probe sensor installed be suitably calibra
81. one del software potrebbe impedire il corretto funzionamento del sistema o renderlo instabile Microsoft consiglia di arrestare l installazione e di contattare il fornitore dell hardware per ottenere un prodotto software che abbia superato il testing del programma Windows Logo Continua Arresta installazione Press Continue Installation Manual Annulla Pag 29 Amico Installation and User Manual Installazione guidata nuovo hardware Completamento dell Installazione quidata nuovo hardware in corso Installazione del software completata per China Vision RF Reader USE C6600 Per chiudere l installazione guidata scegliere Fine Indietro Fine Annulla Press End 2 3 4 Initial Configuration of the WinAmiFree software Upon the first start up of the WinAmiFree software certain configurations are necessary so as to be able to manage the AmiTags and receive data from the AmicoOnLine server 2 3 4 1 Enabling AmiDesktop for card codification optional Double click the WinAmiFree icon to execute the program and click the AmiDesktop button A message indicating the first execution of the program will appear Bring the program AmiTag near the reader and confirm the AmiDesktop search If the message AmiDesktop has been detected Program card Valid is displayed the program has been configured correctly Close the program 2 3 4 2 Enabling AmicoOnLine software for data transfer from the Inter
82. ree management Software Pag 75 Amico Installation and User Manual 8 Litres dispensed 9 Kilometres driven since the previous refuelling or hours passed 10 Consumption average in Km litre 11 Pump number from which the refuelling was made 12 Name of the driver only if identified by the Driver AmiTag or by the driver code 13 Job order number only if requested by the Vehicle AmiTag When the kilometres entered are not coherent with respect to those previously entered the partial consumption average is not calculated The consumption averages for the period are calculated on the refuellings with the corrected partial average When 2 refuellings in sequence have the same Km the average consumption is calculated on the second refuelling summing the litres dispensed in both Kilometres driven are the sum of the driven column 4 6 3 Data modification and Km correction In the report of the consumption averages it is possible by clicking on a refuelling to carry out the modification of the data and manually correct the settings of the mistaken kilometres Click on a refuelling Correzione dei chilometri Humero commessa Varia num automezzo Data e Ora Autista Chilometri Litri Percorsi Km L Litri Ore 09 0 1986 1718 oom E26027 moso ose fosoz fosoz 1 07 1896 15 5 ooo J amp pete3 o080 04 miss o259 Jo2s9 1 07 1996 1452 oom 526529 orino2 osae fosis fosis ff cancella i It is possible t
83. ription To have a report of the expired scheduled maintenance procedures set the appropriate filters 9 11 12 13 and click on Rapporto delle manutenzioni WinAmiFree management Software Pag 90 Amico Installation and User Manual Report Window WinAmiFree r 01 11 10 c 2001 2009 by fabrizio amp binotti1i com Rapporto delle manutenzioni controllate 0001 AA 000 BB IVECO 190 AUTOCARRI Km attuali 120000 Scadenza Ogni Descrizione della manutenzione X SCADUTA il 01 02 09 000365 Bollo X SCADUTA a km 100000 030000 Cambio Olio Motore 4 8 3 Saving scheduled maintenance procedures performed When a new scheduled maintenance procedure is carried out it is necessary to record it in the WinAmiFree software to eliminate the notification of the expired scheduled maintenance procedure and reset the check for the next deadline Select the scheduled maintenance procedure in the main screen and click on the ENEMIES button Registra la manutenz O X automezzo 0001 AA 000 BB IVECO 189 AUTOCE Chilometraggio attuale Anteporre il simbolo per le manutenzioni a scadenza in giorni Manutenzione ES Manutenzione da effettuare ogni Prossima scadenza al km o ore km o ore Manutenzione eseguita in data sabato 29 febbraio 2009 Chilometri o ore al momento della manutenzione 120000 y OK Enter the date and time and the kilometres of the vehicle on which the schedule
84. rs The enabling of refuelling comes about at the end of the requests carried out Below the more frequent programs will be described 2 4 1 1 1 AmiTag Vehicle and kilometre request from the odometer Enter the kilometres read on the odometer of the vehicle and press Extract the AmiTag and begin refuelling 2 4 1 1 2 A AmiTag Vehicle request kilometres and request driver code Installation Manual Pag 32 Amico Installation and User Manual Enter driver code for his her identification see 04 9 4 Enter the kilometres read on the odometer of the vehicle and press Extract the AmiTag and begin refuelling 2 4 1 1 3 AmiTag Vehicle request kilometres and Driver AmiTag First insert Driver AmiTag Insert Vehicle AmiTag Enter the kilometres read on the odometer of the vehicle and press Extract the AmiTag and begin refuelling 2 4 1 1 4 Driver AmiTag and enter the vehicle number to be refuelled First insert Driver AmiTag Installation Manual Pag 33 Amico Installation and User Manual Enter the vehicle number to be refuelled and press Enter the kilometres read on the odometer of the vehicle and press Extract the AmiTag and begin refuelling 2 4 1 1 5 Check and verify the kilometres and any eventual errors Amico carries out a check of the kilometres entered and if specified in the parameters of the Vehicle AmiTag it may block refuelling in the event of a kilometre reading error Or else it may predetermin
85. s All of the data acquired independently of the data download method will be placed in the refuelling archive where it is possible to request reports on the consumption of fuel WinAmiFree COR Archivio Storico A Dall inizio del mese scarso Rifornimenti Esterni Da gioved 1 gennaio 2008 Ec Corregge Data e Ora A mercoledi 25 febbraio 2009 pra Pee lt Tutiipodtt gt mj Disabilita o Abilita Carte Giacenza in cisterna Automezzo Limita o Preseleziona Sulla pompa n Dal mezzo n al n Ripeti per ogni n pompa Num commessa Visualizza solo i totali AmiDeskCL Caratteri ricevuti D Errori nel CE 0 4 6 1 Refuelling visualisation filters Before requesting a report it is possible to select some filters that allow the evaluation of only a part of the refuellings in the archive e Selection of the period of time Dall inizio del mese scorso Rifornimenti Esterni Da gioved 1 gennaio 2009 A gt mercoled 25 febbraio 2009 Select a period that has been pre set or else manually enter the start date and the end date e Product WinAmiFree management Software Pag 73 Amico Installation and User Manual Prodotto Tutti prodotti In plant systems with more than one product this allows the filter for only one product dispensed so as to not mix the products in the analysis of the consumption averages e Group Gruppo hd In the vehicle identifica
86. s that are desired and click on the button o Mese Report Window DX WinAmiFree r 01 11 10 c 2001 2009 by fabrizio binotti com uel sie dal n 0501 al n 0502 Medie chilometriche Automezzo 0501 2 a e ora ista Km Percorsi 02 07 1996 17 28 0001 523161 0210 08 E Binotti Fabrizio 04 07 1996 03 18 0001 524041 0285 04 d Binotti Fabrizio 04 07 1996 15 32 0001 524541 0153 88 E Binotti Fabrizio 06 07 1996 09 13 0001 524960 0140 06 Binotti Fabrizio 09 07 1996 03 06 0001 525709 0245 06 a Binotti Fabrizio 3 09 07 1996 17 18 0001 526027 0105 02 Binotti Fabrizio 10 07 1996 15 31 0001 526183 0060 04 Binotti Fabrizio Totale litri erogati 11359 28 Consumo medio 1 Chilometri percorsi calcolabili 3680 4 Automezzo 0502 z ia Percorsi y Nome autista SL 01 07 1996 19 00 0014 068362 16 03 07 1996 18 48 0001 069595 1233 z Binotti Fabrizio 05 07 1996 18 31 0001 070692 E 1097 i Binotti Fabrizio 09 07 1996 18 12 0001 071570 Binotti Fabrizio 10 07 1996 18 46 0001 072132 ha E Binotti Fabrizio Totali erogati per Pompa Pompa Totale litri 5 0001 0002790 42 Filters set before report creation Vehicle Heading AmiTag number license plate and description Vehicle refuelling Total litres dispensed to that vehicle and average consumption for the period Total litres dispensed per pump Date and time of the refuellings am 2 ae ok a Kilometres entered by the operator at the moment of refuelling WinAmiF
87. sary to differentiate the type of product dispensed from the pumps for example to separate consumption of diesel fuel from that of urea or motor oil To set the type of product in the cistern click on the b u tt on Cisterne Cisterne fs Giacenze in cisterna N CISTERNA Prodotto erogato Gasolio v First of all it is necessary to inform the program of the configuration of the plant system that is to specify the combination of the pump number with the cistern For example considering a multiple plant system with 2 Amicos the first is connected to pump 1 and pump 2 which are both connected to a diesel fuel cistern the second is connected to pump 3 with one cistern of diesel fuel and pump 4 connected to a cistern of urea ate Click on the symbol click Yes and select the pump 1 Cisterne N POMPA N CISTERNA Gasolio v Associate pump 1 to cistern 1 and to diesel and repeat the operation for pump 2 Cisterne amp N POMPA N CISTERNA 02 01 Prodotto erogato z X mad Associate pump 3 and pump 4 to their respective cisterns WinAmiFree management Software Pag 65 Amico Installation and User Manual Cisterne Cisterne EI E3 N POMPA N CISTERNA N POMPA N CISTERNA 03 04 04 Prodotto erogato Gasolio Prodotto erogato v mas Que gia In the archive from this point on it will be possible to use the filter for the type of product WinAmiFree mana
88. sensor 20 2 3 Configuration or the Amico SYStEemMi nile ea lana 21 2 3 1 Configuration of the Amico control unit ii 21 2 3 1 1 Configuration of the plant system parameters seen 21 2 3 1 2 Configuration of parameters for a multiple plant system 21 2 3 1 3 Configuration of customisable parameters iii 22 2 3 1 4 Configuration of the stock and of the electronic counters ttt 22 2 3 1 5 Configuration of the AmiTags to enable refuelling ueeeeeees 22 2 3 1 6 Configuration of the level probe sensor i 23 2 3 2 Installation of the WinAmiFree Software eee eee nennen enne nennen 24 2 32 01 Step DY SLED InsSt FUctlofis s icta ibi t A eiae LUE 24 2 3 3 Installation of AmiDesktop Contactless eese enne nnn nnnm 27 2 3 4 Initial Configuration of the WinAmiFree software essen mmm 30 2 3 4 1 Enabling AmiDesktop for card codification optional 30 2 3 4 2 Enabling AmicoOnLine software for data transfer from the Internet only for AMIcO WIth AOL IMOGUIC sione PE Ex prO DUE NE mU I RARE aaa 30 2 3 4 3 Enabling direct connection via cable Amico micro modem 31 2 liue dor inuiUls pc 32 24 11 ElstRerJelllbig usesbenawesueve aset omuadauE eESE VES Ur aden Par EE les VPRVIVE TREES URS EINE TUDIN 32
89. t in base a quanto previsto dalla direttiva CEE 299 336 successiva 92 31 e decreto lagislativo N 476 82 ISCR TRIB VIGEVANO N 8805 C C LA A N 184704 C F e P IVA n 0417870182 Declaration of CE conformity Figure 12 Attachments Pag 103 Amico Installation and User Manual 5 2 Attachments CE Tag BINOTTI snc Via Cavour 88 Sartirana ITALY 7T3 23 CEE 88336 CEE www binotti com SERIAL NUMBER ANNO DI PRODUZIONE Lo f l ALIMENT AZIONE APPARECCHIOC NON IDONEO ALLA MISURAZIONE DI PRODOTTI FER LA VENDITA AL PUBBLICO NE VIETATO L USO IN RAPPORTO CON TERZI ART 082 C P C M M 37 DEL 27 13 1898 CE Tag Figure 13 Pag 104 Amico Installation and User Manual 5 3 Containers Dimensions expressed in mm Dim max L 370 x H 290 x D 175 P370 with protective cover Weight 4 Kg Dimensions Dim max L 370 x H 450 x D 175 P370 with protective cover Weight 7 Kg 00000 9299 2900 4 Attachments Pag 105 Amico Installation and User Manual Dim max L 241 x H 241 x D 90 Weight 3 Kg Dim max L 245 x H 465 x D 135 Weight 4 Kg Container CA 04 Figure 17 Attachments Pag 106 Amico Installation and User Manual Dim max L 410 x H 340 x D 360 Weight 8 Kg Attachments Pag 107 Amico Installation and User Manual 5 4 Component location ANI PAS inott com Tie E TASTIERA zd EET SEES Gp ip gr 2 B t 2 HW J2 di sea nv S
90. t at guessing what the code is 3 1 4 End refuelling memorisation and transmission of data to the AmicoOnLine server Enabling refuelling is denied by Amico in one of the following conditions e The SECONDS TERM FOR REFUELLING has elapsed The seconds since the flow of fuel has been stopped the timing def 20 sec may be changed in the function Seconds Term for Refuelling in the CUSTOM PARAMETERS MENU Timing begins for example User Manual Pag 45 Amico Installation and User Manual when the automatic dispenser hand unit starts If the operator does not initiate the top up procedure the refuelling is stopped e The SECONDS TERM FOR INITIATE REFUELLING has elapsed The seconds since on the display the message appeared saying DISPENSE have passed and the refuelling has not been begun The timing def 60 sec may be changed in the Seconds Initiate Refuelling function in the CUSTOM PARAMETERS MENU This timing is useful for the case in which an operator forgets to refuel when it has been enabled avoiding that fuel be dispensed to another vehicle e The dispenser hand unit has been replaced in the pump and the hand unit is connected to Amico e The maximum number of litres dispensed has been reached limited by the kilometres driven or by the limitation on litres that may be dispensed A power failure has turned Amico off Once the fuel has been dispensed the refuelling is memorised and in the versions with the AOL modem
91. t timing and to correct the system clock Insert the Program Tag and enter the CUSTOMISABLE PARAMETERS menu see RESTRICTED PARAMETERS MENU There are 2 timing procedures one is the number of seconds at the beginning of the refuelling and the other the number of seconds at the end The time in seconds at the beginning of the refuelling indicates the maximum amount of time in which the refuelling procedure must begin If for some reason the refuelling does not start min that time the motor will be disconnected and it will be necessary to bring the Tag close to the reader again Start refuelling seconds function The time in seconds at the end of the refuelling indicates after how much time the pump motor will be disconnected from the moment that the dispensing stops even if the fuel dispenser hand unit is not replaced in its seat Stop refuelling seconds function 2 3 1 4 Configuration of the stock and of the electronic counters The stock in the cistern tank allows the calculation of the quantity of product in the cistern subtracting the litres dispensed from the stock value entered In the configuration with a level probe sensor the logic stock is substituted by that of the sensor probe Introduce the Program Tag and enter the STOCK IN CISTERN menu see CISTERN STOCK MENU Verify the litres in the cistern tank by way of the metric dipstick or by way of the litre counter of the tank truck that has unloaded product and insert the
92. tallation Manual Pag 15 Amico Installation and User Manual 2 2 2 Installation Sequence 1 Assemble the electrical control panel to the Amico control unit and run the connection cables as per the regulations in force All of the Amico control unit cables input output must be sealed and locked by cable chocks Attach the impulse emitter on the mechanical head of the distributor and bring the 3 wires and channel inside of the Amico control unit and eventually the 2 contact wires for insertion into the fuel dispenser hand unit Connect the cables into the M4 terminal strip for pump 1 if pump 2 is present repeat the connection on M5 Connect the 220 V AC mains electrical power supply to the Amico control unit on the terminal strip 5 0 220 V AC by way of a cable with a nominal section of 2 5mm with phase neutral earth Turn the switch to the AUTOMATIC position to activate the control unit FO IN 220 Vac EL F2 JP1 JP2 M4 M5 Amico I O data card Figure 7 1 Not used present only for compatibility with R1 0 Amico Data Card 2 Selector automatic manual enables the pump operation by deactivating the electronic data card manual In manual operation no refuelling is recorded 3 Flat connector for connection to Amico 2005 data card Installation Manual Pag 16 Amico Installation and User Manual e FO fuses transformer output F0 12 24 3 15A F0 24 3 15A e IN 220 V AC 220V 50 Hz ele
93. ted with a table of values cm litres A table of this type may be entered directly into the electronics of the probe sensor or it may be obtained by calculating the calibration table directly on site with a procedure called self calibration only in the AmicoOnLine versions If the calibration table for the cistern is entered into the level probe sensor enable the Calibration in the sensor probe function Amico will then receive the quantity in litres inside of the cistern from the sensor If the calibration table is not present in the sensor it is necessary to carry out a self calibration of the system only with the AOL model How to initiate self calibration e Fill the cistern up to its maximum level Wait 15 minutes so that the level will stabilise e Set the stock value in the function Initiate cistern 1 2 calibration in the CISTERN STOCK MENU the function appears only with the activate GPRS services function activated in the AMICO ON LINE MENU Installation Manual Pag 23 Amico Installation and User Manual After having entered the beginning of the calibration Amico will transfer the command to the AmicoOnLine server In the event of an error in the connection it will be necessary to repeat the operation From this moment onward at each refuelling carried out the level is transferred to the internet server which elaborates the calibration table e Reach the absolute minimum level possible and replenish the
94. ter in the equipment connected by cable or to AmicoOnLine 3 1 5 2 3 List AmiTags Disabled This visualises the list of all the disabled AmiTags On the display the number of the first Tag disabled appears Push to scroll the list or else to exit 3 1 5 2 4 Enable all Tags This enables all Tags so as to be able to carry out refuelling O Push 1 and to enable all Tags 3 1 5 2 5 Disable all tags This disables all Tags from being able to carry out refuelling This enables those authorised with the Enable an AmiTag function Push 1 and Ok 3 1 5 3 MENU DISABLE DRIVER AMITAG These are the same functions as MENU DISABLE VEHICLE AMITAG but they disable the Driver AmiTag 3 1 5 4 MENU AMICO ON LINE In this menu it is possible to inform AMICO that inside of it the module AOL AmicoOnLine is connected for the connection of Amico to the AmicoOnLine server Activating the following function the transfer of data will take place online by way of a telephone SIM card Activating the online operation the following services will automatically be activated e Refuellings are transferred to the server immediately after having been completed User Manual Pag 52 Amico Installation and User Manual e The stock is synchronised to that of the server and may not be varied with the Program Tag e If the level sensor probe is activated the auto calibration of the cistern is activated e The minimum reserve message is sent by S
95. tion lists it is possible to associate an affiliation group to each vehicle ex TRUCKS AUTOMOBILES EARTH MOVERS etc This filter allows the list of refuellings to be made for just one group e DRIVER Autista Allows the filter of all of the refuellings performed by one driver only if identified by the Driver AmiTag or by a driver code e VEHICLE Automezzo This allows the filter of the refuellings for the vehicle selected e From vehicle number to vehicle number Dal mezzo n EN zm Only the refuellings of vehicles within the specified interval will be visualised e PUMP NUMBER sulla pompa n __ Filters the refuellings at the pump indicated e Automatic pump number filter Ripeti per ogni n pompa This recreates the report selected automatically varying the filter on the number of the pump selected for all of the pumps in the refuelling archive e Job order number Num commessa If the request for the job order number has been set on the vehicle pass card it filters the refuellings for that job order WinAmiFree management Software Pag 74 Amico Installation and User Manual e Only total dispensed Visualizza solo i totali This eliminates the individual refuellings lines from the report showing only the totals 4 6 2 Average consumption report This is the report that groups the refuellings by vehicle to analyse the average kilometric consumption Set the filter
96. tonomy indicates the number of kilometres or hours that the vehicle may have been driven since the last refuelling The kilometres entered are considered in error if greater than the sum of the kilometres at the last refuelling and those of the maximum autonomy 16 17 in figure Minimum kilometres driven indicates the how many kilometres or hours the vehicle must have been driven to have then been refuelled The kilometres entered are considered in error if less than the sum of the kilometres at the last refuelling and those of the minimum to be driven 16 18 in figure Consumption in km litre from to indicates the maximum and minimum consumption estimated for this vehicle so as to predetermine the maximum number of litres to be dispensed as a function of kilometres driven For example if the kilometres at the last refuelling are 10 000 the consumption set is from 2 to 4 km litre and the operator would enter 10 500 The refuelling is predetermined at 250 litres the maximum number of litres that could have been consumed after 500 kilometres driven Limits the operation of this AmiTag on the pumps that dispense the product indicated 0 indicates that there are no limits on the product The products management Software Pag 94 Amico Installation and User Manual 21 22 23 24 25 26 27 28 29 30 WinAmiFree dispensed are numbered in the Amico equipment at the heading Product Numbering P 1 2
97. uch as refuelling performed at roadside sales points is what is meant by external refuelling The driver at the time of the refuelling on Amico must manually enter the litres dispensed externally so as to permit a correct calculation of the consumption average Push the cistern button before entering the kilometres Enter the external litres and press Ok Continue with the normal refuelling procedure Two refuellings are memorised with the same date same kilometres but different litres one of which is on pump 99 which indicates the manual refuelling entry so as to distinguish it from that made by Amico 3 1 3 Error messages during the enabling of the refuelling The AmiTag is not operational or has been inserted too slowly Repeat the operation User Manual Pag 44 Amico Installation and User Manual The Vehicle AmiTag was inserted before the Driver Tag The Km value entered is lower or higher than the autonomy of the vehicle in relation to the previous refuelling Push and correct the kilometres Or else sun OK to continue Just as in the previous message but without the possibility of continuing because there is a blockage on the entry of the kilometres set on the AmiTag The Vehicle AmiTag was extracted before the kilometres were entered Reinsert it into the reader The PIN code or the driver code entered is not correct At each attempt to enter the error message increases the wait time so as to avoid an attemp
98. value in the cistern Cistern Stock 1 2 function The electronic counter allows verification once it has been synchronised with the mechanical counter of the dispenser that all of the refuellings are carried out with the Amico control unit in operation In the event that this latter were to be excluded manual operation the electronic counter would not run Synchronise the electronic and the mechanical counters of the pumps Dispenser pump counter 1 2 function 2 3 1 5 Configuration of the AmiTags to enable refuelling Once an AmiTag is brought near the Amico reader the control unit reads its characteristics and requests that the operator follow the procedures set out in its parameters The enabling of refuelling comes about at the end of the requests carried out Installation Manual Pag 22 Amico Installation and User Manual So as to define how to programme the AmiTags it is necessary first of all to either identify the vehicle to be refuelled the operator or both In general it is more important to identify the vehicle to be refuelled since the consumption of fuel as a function of the distance travelled or of the meter is referred to the vehicle In this case it would be necessary to distribute AmiTags to each vehicle that is to be authorised to refuel The identification of the operator is added information that might be necessary when drivers change the vehicles they operate daily The identification of the operator may c

Download Pdf Manuals

image

Related Search

Related Contents

HQ -INV1KW/12  Proel PSE2MKII microphone  Manual de servicio del servidor Sun SPARC Enterprise T5440  User Manual Configuration and Administration Guide BAT54  Black Box FLUKE-787  Technical information and operating instruction Technische  NEC Express5800 Printer User Manual  Scaffold - Proteome Software - Wiki  Learning Resources LER3060  RAM Mount RAM-VP-SW1-4-2461 holder  