Home

User manual Borri Power Guardian

image

Contents

1. 2 3 16 Action When Power Recovery lown is be canceled IV If power recovery OS shutdown cou Cancel OS countdown when power recovery or not Page 18 Boel 2 4 SMS UPS Monitoring Software User Manual An alert message of recorded event will be sent to a predetermined mobile phone number via a subscribed short message service provider SMS Setting oe This SMS function is only available through third party Short Message Service Providers To use this function you need to subscribe an account on every8d or clickatell These are currently the only 2 third party SMS providers supported by Borri Power Guardian program For more information on subscriptions and charges please go to their respective website as follow 1 For Every8d Go to http www every8d com Note Please subscribe as Corporate account in order to use Borri Power Guardian program SMS function 2 For Clickatell Go to http www clickatell com Note Payment has to be made to obtain an api_id before use A Send Test Click to send a test message to confirm the settings Page 19 Bowel UPS Monitoring Software User Manual B Account Settings Insert the SMS provided name ID passwords api id for Clickatell subscriber only and mobile phone number international dialing format include or 00 and country code Note If you want to send message to more than 1 mobile phon
2. Please use Windows Update to check for any critical updates to the NET Framework as Page 4 Bweel UPS Monitoring Software User Manual 1 3 Instructions on Removing Borri Power Guardian Program Remove Borri Power Guardian Step1 Go to Windows Control Panel and select Programs and Feature Step2 Select Borri Power Guardian and click Remove or Uninstall Organise Uninstal Change Repair D Step3 In the page shown below click Yes to confirm removal of the Borri Power Guardian or click No to cancel the removal A Are you sure you want to uninstall Born Power Guardian Inthe future do not show me this dialogue box Step4 When the progress bar run to finish It s complete the removal Borri Power Guardian Icon will disappear in the Add or Remove Programs page Borri Power Guardian fp aaa Page 5 Bowel UPS Monitoring Software User Manual 2 Function Descriptions Borri Power Guardian program is user friendly UPS monitoring software which reveals the status of the UPS via USB or RS232 for up to 4 parallel units It provides easy to read real time metering of important UPS parameters such as input output voltage frequency UPS tempe rature loads amp battery capacity These UPS parameters amp status information are recorded and presented in both graphically and numerically The Schedule function of Borri Power Guardian allo
3. Setup Type Windows Installer Package Size 4 41 MB 1 2 3 Click Next to next step Welcome to the Borri Power Guardian Setup Boel The installer wil guide you through the steps required to install Borri Power Guardian on your computer WARNING Lycee arnie pride gy ela ae onc Unauthorized or distribution of od ge abi soci dp de de Nada or criminal penalties Sood ll vo prstnizadia Do di cli palate od the law pack CR Page 2 Bweel UPS Monitoring Software User Manual 1 2 4 Enter Select Installation Folder to select the desire location for this program Default C Program Files Borri Power Guardian Choose the user yourself or anyone who uses this software Click Next to next step Select Installation Folder Bowel www borri it The installer wall install Borni Power Guardian to the following folder To install in this folder click Next To install to a different folder enter it below or click Browse 1 2 5 Enter Confirm Installation to ensure the completed installation of Borri Power Guardian Click Next to next step Confirm Installation The installer is ready to install Bomi Power Guardian on your computer Click Next to start the installation Page 3 Devel UPS Monitoring Software User Manual 1 2 6 Installing Borri Power Guardian program Installing Borri Power Guardian 1 2 7 Click Close to end the installation
4. Bweel ups Monitoring Software User manual Borri Power Guardian LINE UPS For Microsoft Windows 8 Microsoft Windows Server 2012 Microsoft Windows 7 Microsoft Windows Server 2008 R2 Microsoft Windows VISTA Microsoft Windows Server 2003 Microsoft Windows XP Microsoft Windows 2000 www borri it Butel UPS Monitoring Software User Manual Borri Power Guardian Table of Contents page 1 Installation amp Settings 2 1 1 Note 2 1 2 Installation Instructions 2 1 3 Instructions on Removing Borri Power Guardian Program 5 2 Function Descriptions 6 2 1 Real Time Information Monitoring Display 6 2 2 Control 12 2 3 General Setting 12 2 4 SMS 19 2 5 E Mail Settings 21 2 6 Data Log 22 2 7 Event log 24 2 8 Schedule 26 2 9 Oscillograph 28 2 10 Power Abnormal Alarm 28 2 11 About 29 mBweel UPS Monitoring Software User Manual 1 Installation amp Settings 1 1 Note gt Operating OS Windows 2000 XP Server 2003 Vista Server 2008 R2 7 Server 2012 8 Other Software Conditions 1 MDAC 2 8 windows 2000 Only http www microsoft com downloads details aspx familyid 6CO50FE3 C795 4B7D B037 185D0506396C amp displaylang en 2 For Windows Installer 3 0 and above 3 For Framework 2 0 and above Peripherals Use either a serial port or USB 1 2 Installation Instructions 1 2 1 Please login as an Administrator 1 2 2 Double click to execute Setup
5. Buck Buck Non Over Load Over Load Over Load Non Battery Disconnect Battery Disconnect Battery State Battery OK Battery Low LINE UPS LOAD Non By Pass LINE UPS LOAD By Pass By Pass Page 9 Bowel UPS Monitoring Software User Manual Meter Page Y 4 y iz Symbols Description State Symbols Description Remarks UPS connected This symbol represent when the UPS is successfully connect to the Computer Connection State UPS disconnected The connection between the UPS amp the Computer is disrupted Power Supply OK Power State Power Failure The utility supply is absent or abnormal conditions Page 10 Boel Symbols Description UPS Monitoring Software User Manual State Symbols Description Remarks K Battery Level OK UPS Battery Battery Low The UPS battery is near to end of discharge or is at low power level State 2 Icon swap UPS Battery Failed ON LINE Model UPS Models OFF LINE Model UPS No Testing Test State UPS Testing By Pass By Pass mode Page 11 Bowel UPS Monitoring Software User Manual 2 2 Control Provides command to UPS for self test shut down battery discharge test stop test etc 2 3 General Setting Allows user to select amp set the connecting Com po
6. Monitoring Software User Manual A Self test for 10 seconds B Self test until battery low C Insert minutes to shutdown the UPS D Insert minutes to shutdown the UPS The UPS will turn on automatically at the predetermined time 2 8 3 Create Delete and Edit the data of Schedule Create Click Add to create a new task Edit Delete Step1 Choose the task from the schedule list the highlighted blue bar is the chosen task Step2 Set Machine and schedule items Step3 Click Edit to modify your selection Choose the task from the schedule list the highlighted blue bar is the chosen task Click Delete to delete the task you choose Page 27 Bowel UPS Monitoring Software User Manual 2 9 Oscillograph The Oscillograph provides a summarized report of the recorded UPS operating data The recorded data are represented in line curves to provide an easy to read summery of the Utility amp UPS power quality Wiss Masa Reape a Sen F oer ae See To Mes LE hene ir nit ee SS 2 9 1 Tools Machine Name Machine 1 v Deb E0128 D OK Data Name All v Time zone 03000359 v Machine Name Choose the machine which you want to show Date Set the date of data you want to show I u Data Name 5 items can be chosen ALL Input Voltage Output Voltage Input Frequency Battery Capacity Time zone Choose the time interval 2 10 Pop
7. initial start up language will be English Data retention setting Days of data retention 0 O Never Delete The period of time user intends to save the data in database If the value is O means data in database never delete Remote Setting Remote Setting Connect Local Machine Connect Remote Machine IP If you want to remote other computer please choose Connect Remote Machine and insert IP If choose Connect Remote Machine you can t send command scheduling and Shutdown the UPS but can Shutdown the computer Enable ACPI Shutdown When Enable ACPI Shutdown all of the Shutdown functions controlled by ACPI Enable ACPI Shutdown ACPI Powr Guardian Shutdown Bweel UPS Monitoring Software User Manual Pop up Warning Message H enable ACP functions OS shutdown controlled by ACP not Monitor Software anymore Monitor Software have only function to display no other control function such as shutdown UPS execute specific program before shutdown Power buffer times arrange Enable ACPI Shutdown When Power Faure OS Shutdown Buffer Time Oo Minie When Battery Low OS Shusiown Buffer Tune Cl Mannie When Power Faure UPS Shutlown Buffer Tune Os Maule When Battery Low UPS Shuidown Buffer Time os Minute When User calle UPS Shuttown OS Shutdown Buffter Time i Mintii 05 Shukown Type Shutdown w a sa C Optional command file to execu
8. 29 07 27 56 2015 04 29 07 2757 2015 0429 07 27 59 2015 0429 07 28 01 Page 22 Bowel UPS Monitoring Software User Manual 2 6 1 Setting Machine Name and date of data Machine Name All v Date Search Choose the Machine Name and Date click Search have the further information 2 6 2 Toolsgs 2015047 2015 04 23 10 06 36 2015 04 23 10 06 39 2015 04 23 10 06 42 2015 04 23 10 06 45 2015 04 23 10 06 48 20150423 10 06 51 20150423 10 06 54 2015 04 23 10 06 8 201540423 10 07 00 201500423 10 0703 20150423 10 07 06 2015 04 23 10 07 09 201500423 10 07 12 201500423 10 07 15 3 oso se ooo oO sos oso so ono ES ee S amp S Ee amp Ee Se ESE Export Click to export the current data into xls format First Click to go to the first recorded entry Last Click to go to the last recorded entry Page 23 Bowel UPS Monitoring Software User Manual 2 7 Event log The Event Log provides a list of records of all the events amp tasks to be performed by the program and those that had occurred on each day of the particular month It provides a summary of the Utilities conditions and UPS testing results 2 7 1 Setting Machine Name and date of data Machine Name AI v D GO seh Choose the Machine Name and Date click Search to have the further information Page 24 Bweel UPS Monitoring Software User Manual 2 7 2 Filt
9. e number must use to separate mobile phone numbers C Event amp Message Selections Click to select the desire Events to be broadcasted and the respective message contents You may change and retype the Message contents to meet your requirement in English D Save Setting Click OK to save amp apply settings Note Internet Firewall may not allow this SMS function If you have installed Firewall please allow this function Page 20 Bweel UPS Monitoring Software User Manual 2 5 E Mail Settings Email Setting of Bor Name Emiy2 User Email Address HOO KM Receiver Name User Mail To X00 KX MX Hallo urs Connected Mail message UPS connect UPS Disconnected Mail message UPS disconnect C Shutdown OS Mail message System shutdown C Power Fail Mail message Power failure Battery Low Mail message Battery low C UPS Shutdown Mail message UPS shutdown C Over Load Mail message Over load C UPS Self Testing Mail message UPS test A Sent Test Click to send a test message to confirm the settings are correct B Account Settings Insert the User Name Sender e g Borri Power Guardian User Email Address select a sender email address specifically for this function Password the pass word of your email server SMTP Server insert SMTP server or IP address SMTP Server port port of SMTP Server Receiver Name select a predetermined email address the event messages will be sent
10. er Filter UPS Connected _ Battery Failed Power Restored Select All C UPS Disconnected C Self Test M Shusown OS Filter _ Battery Low _ Over Load Please select or unselect the desire parameters by clicking on the respective parameter field box Click Filter to have further information Select All Field box of all events will be Ml Clear Field box of all events will be Filter Click Filter the data will show respectively 2 7 3 Tools Work Progress 2009 1 1 05 11 02 50 Macho 2009 1 1 05 11 12 51 2009 1 1005 11 13 39 2009 1 10S 16 19 26 2009 1 1 05 16 40 48 Machine 1 UPS Disconnect Export Click to export the current data into xls format First Click to go to the first recorded entry Last Click to go to the last recorded entry Page 25 Bowel UPS Monitoring Software User Manual 2 8 Schedule Schedule allows user to create a desire routine to notify UPS to perform specific or repeatable tasks automatically at predetermined dates amp times Please refer to the following instructions to create an entry 2 8 1 Setting Machine and time which you want to schedule Machine Name Machine ov Date 2015 04 23 Thursday E fe om Repeat y Machine Name Choose the machine Date Choose the Date Time Time Setting Repeat Set frequency Page 26 Boel UPS
11. n Buffer Time When User calls UPS Shutdown OS Shutdown Buffter Time w 1 Minute Select a desire time to automatically shutdown the computer OS before UPS shutdown The selectable time is from 1 min to 99 min NOTE Before UPS or OS shutdown Borri Power Guardian will show countdown window Countdown for OS Shutdown 39 Page 16 Bowel UPS Monitoring Software User Manual 2 3 13 OS Shutdown Type OS Shutdown Type Shutdown If the shutdown type selects Hibernate as OS it s 2 3 14 Optional command file to execute after OS started countdown Select a desire time to execute specific file automatically after OS started Shutdown Optional command file to execute after OS started countdown l Minute Browse 2 3 15 Auto save Application Provides a function to save program when OS shutdown AutoSave Application Files saved Log Display Closed Files Record on Power Guardian Restart Auto close and save Application Files before OS shutdown _ AutoSave Application Files When restart Power Guardian Pop up the list of Closed Files C Display Closed Files Record on Power Guardian Restart Record Log Page 17 mBweel UPS Monitoring Software User Manual Save AutoSave Directory under My Document Documents library annie a Indudes 2 locations Name Date modified Type Sue AutoSave 3 25 2014 3 04FM Fie folder
12. nd entries alarms etc Data Log Stores the UPS operating parameters monitored amp recorded by the Borri Power Guardian About Record the version number and proprietor name of the Borri Power Guardian B C1 CZ Parallel Unit Information Provides input output voltage frequency loads of UPS parameters for up to 4 parallel units at the same time Real Time Information When you select unit in Parallel Unit Information zone the details of UPS parameters will show on this zone This zone includes Icon page Value page Rating Information and Machine Information Rating Information Provides rating information of the connected UPS such as Rating Voltage Rating current Battery Voltage and Frequency Machine Information Provides machine information of the connected UPS such as Manufacturer UPS Model and Firmware Version Page 7 mBweel UPS Monitoring Software User Manual Power Flow page mie a Machine Retag Infocmaton Rated Voltage 0 v Input Frequency 0 Hz prat F Input Voltage 0 Vv Battery Voltage 0 v Frequency LINE UPS LOAD a Output Voltage Machine Indosmaton g y Mamafa tuper UPS Load UPS Model 0 G Battery Capacity 0 Te re Temperature 0 0 320 F Page 8 mBweel UPS Monitoring Software User Manual Symbols Description State Symbols Description Remarks Non Boost Boost _ ge Pace Non Buck
13. rt or Remote UPS or OS shutdown etc CO Enable ACP Shutdown 0 Pow Guardian Shutdown When Power Failure OS Shutdown Buffer Time Page 12 Bowel UPS Monitoring Software User Manual O Enable ACP Shutdown Powr Guardan Shutdown When Power Failure OS Shutdown Buffer Time When Battery Low OS Shutdown Buffer Time When Power Failure UPS Shutdown Buffer Tune When Battery Low UPS Shutdown Buffer Time When User calls UPS Shutdown OS Shutdown Buffter Tune OS Shutdown Type Shutiown v Optional command file to execute after OS started countdown Browse AutoSave Application Files Display Closed Files Record on Power Guardian Restart If power recovery OS shutdown countdown is be canceled 2 3 1 Setting amount of unit and choose the Protocol Total Unitof Machine 1 vl Protocol 2 3 2 Setting number of unit and unit name which show on the Real Time Information Monitoring Display form Name Machine 1 Machine Number 1 vl Machine 2 Machine Number 2 Machine 3 Machine Number 3 Machine 4 Machine Number 4 __ Page 13 Boel Page 14 2 3 3 2 3 4 2 3 5 2 3 6 2 3 7 UPS Monitoring Software User Manual Setting Interface and Com Port of connection Communication Interface Com Port Com v Ban et Language Selections Langage English e The Borri Power Guardian program provides various major languages for user selection The
14. te after OS started countdown l Manute Browse 1 Display Closed Files Record on Power Guardian Restart If power recovery OS shutiown countdown is be canceled 2 3 8 When Power Failure OS Shutdown Buffer Time When Power Failure OS Shutdown Buffer Time Y 5 Minute Select a sufficient time for the computer OS to automatically shutdown when a power outage occurred The selectable time is from 1 min to 99 min 2 3 9 When Battery low OS Shutdown Buffer Time When Battery Low OS Shutdown Buffer Time 4 Minute Select a desire time to automatically shutdown the computer OS before the UPS battery power is depleted The selectable time is from 1 min to 99 min Page 15 Bowel UPS Monitoring Software User Manual 2 3 10 When Power Failure UPS Shutdown Buffer Time When Power Failure UPS Shutdown Buffer Time V 3 Minute Select a desire time to automatically shutdown the UPS after a power outage occurred A longer shutdown buffer time for OS then the UPS one is highly recommended The selectable time is from 1 min to 99 min 2 3 11 When Battery low UPS Shutdown Buffer Time When Battery Low UPS Shutdown Buffer Time 4 2 Minute Select a desire time to automatically shutdown the UPS before the UPS battery power is depleted A longer shutdown buffer time for OS then the UPS one is highly recommended The selectable time is from 1 min to 99min 2 3 12 When User calls UPS Shutdown OS Shutdow
15. to Mail To Mail address of receiver and Subject select a subject name to acknowledge the receiver Note If you want to send email to more than 1 email address must yy use to separate email addresses C Send Setting Click to select the desire Events to be broadcasted and the respective message contents You may change and retype the Message contents to meet your requirement in English Page 21 Bowel UPS Monitoring Software User Manual C Send Setting Click to select the desire Events to be broadcasted and the respective message contents You may change and retype the Message contents to meet your requirement in English D Save Setting Click OK to save amp apply settings Note Internet Firewall may not allow this E Mailing function If you have installed Firewall please allow this function 2 6 Data Log The Data Bank stores all UPS operating parameters monitored amp recorded by Borri Power Guardian program It facilitates the recorded data include Input Voltage Output Voltage Input Frequency Battery Capacity Temperature Load for a more effective study of the desire information The information in the Data Base can be exported to Excel file 201 5004 29 07 27 40 201 5004 29 07 27 41 20150429 07 27 43 2015 04 29 07 27 44 201590429 07 27 46 201504229 07 27 47 20150429 07 27 49 201504729 07 27 50 2015 0429 07 27 52 2015 0429 07 27 53 2015 04 29 07 2755 2015 04
16. up alarms for Power Abnormal When UPS happens one of Power Fail Battery Low Battery Failed and Overload it will show alarm window in order to remind user to prompt handle Power Fail Page 28 Bweel UPS Monitoring Software User Manual 2 11 About www borri it Yersion Borri Power Guardian 2 1 0 Copyright 2015 Bomi SpA Click to confirm version of the Borri Power Guardian software Click Help to show this user manual Page 29 L590 1 ArevA 07 2015 Borri S p A Via 8 Marzo 2 52011 Bibbiena Arezzo Italy phone 39 0575 5351 fax 39 0575 561811 www borri it
17. ws user to preset various UPS commands to perform repetition of tasks automatically In event of Power outage or abnormality Borri Power Guardian program is capable of automatically informing user via SMS amp email instantly and closes application software The following chapters will provides detailed descriptions of these superior features of Borri Power Guardian program 2 1 Real Time Information Monitoring Display SE i ie NED oc Y C Real Time dafermation Input Frequency 0 Input Voltage 0 LINE UPS Output Voltage 0 V Information UPS Load 0 Q Battery Capacity 0 amp Temperature 00 320 F Page 6 mBweel UPS Monitoring Software User Manual A Tools Field Function Descriptions Remarks Schedules Provides scheduling of to do events and commands Oscillograph Graphical overall of the recorded UPS parameters data Data Base There are 2 parts in this item Event Log And Data Log Control This function include Self Test UPS Shutdown In this function you can send command to unit in this time There are 3 parts in this item General Setting SMS Setting And Email Setting General Setting setting of Communications Multi language Setting of Shutdown SMS Setting SMS alert function set up E mail Setting E mail alert function set up Event Log Provides a list of records of events comma

Download Pdf Manuals

image

Related Search

Related Contents

SW5002 Wireless Serial Server  MDVK071  G-SS Gimbal User Manual \“wo'kem  Emerson 912N Instruction Manual  118 P - 600 PX - Nilfisk PARTS  Favoriser le développement des enfants - Extranet  Manuel d`installation - Böhnke & Partner GmbH  Expressio_Paname Convention Intimiste Paris, Le Petit Baigneur    組立・施工説明書  