1. 59 06 313 D 3382 100 D 3382 201 01 13 02 Sirona Dental Systems GmbH 16 Extra equipment and accessories Operating Instructions C4 16 2 Hygienic headrest protection for motorized headrest Hygienic headrest protection for motorized headrest Accessory Two different hygienic covers are available for the head rest of the patient chair e Washable textile headrest cover with Velcro closure and neck pad REF 59 05 588 5 pcs e Disposable headrest cover with a self adhesive fas tening REF 58 72 820 5 pcs Slip the headrest cover over the headrest and fasten it as illustrated Extra equipment The back part is fastened with a Velcro closure and can be removed Covering material 100 cotton The covers can be removed after opening the Velcro strap on the back The covers are Teflon coated Instructions for care The Teflon coating is dirt repellent and slightly water repellent remove any dirt with lukewarm soap suds fine washing powder A CAUTION Removing stains with stain remover is not suitable since it damages the Teflon coating This comfortable seat is simply placed on top of the upholstery of the patient chair Thus it is possible to posi tion the heads even of small patients on the headrest 59 06 313 D 3382 D 3382 201 01 13 02 101 16 Extra equipment and accessories Sirona Dental Systems GmbH 16 4 Folding armrest Operating Instructions C4 16 4 Folding armrest
2. Operating Instructions C4 General information Sirona Dental Systems GmbH Operating Instructions C4 E General information Dear customer We thank you for purchasing your C4 dental treatment center from the Sirona company The technical documentation supplied is also part of the product You should always keep this documentation within reach These Operating Instructions describe your treatment center with maximum possible equipment For daily care of your treatment center please observe the instructions provided in Care and Maintenance by the Practice Team To safeguard your warranty claims please complete the attached Installation Report Warranty Passport together with the service engineer immediately after the installation of your treatment center Separate Operating Instructions with corresponding instructions for care are enclosed with the dental instruments SIROLUX FANTASTIC monitor Cerec Chairline SIROCAM 3 tray and X ray image viewer Prior to start up you must read all Operating Instructions to familiarize yourself with the treatment center To prevent any personal injury or material damage pay special attention to any notes printed in bold type or marked in one of the ways indicated below ao a e Additional information explanation or supplement i NOTE cauron gt gt gt The information provided under this keyword directly CAUTION concerns the functioning o
3. gt Check the guide of the removed headrest for con tamination Remove any contamination gt Remove the cover cap E DANGER Reinsert the MultiMotion in the guide from above until it audibly locks in place Pull on the headrest again to make sure that it is locked securely in place 33 8 Patient positions 8 4 Adjusting the patient positions manually Sirona Dental Systems GmbH Operating Instructions C4 8 4 Adjusting the patient positions manually lt 7 8 2 8 N 34 You can start the motorized chair movements manually with the keys in the right block on the dentist element control panel Backrest tilt You can tilt the backrest also with the 4 way foot control on the chair base Lever to the left The backrest tilts backward Lever to the right The backrest tilts forward Height adjustment You can adjust the height also with the 4 way foot control on the chair base Lever up The chair moves up Lever down The chair moves down 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 8 Patient positions Operating Instructions C4 8 5 Motorized headrest Motorized headrest Moving the headrest in out Move the headrest out in by pushing the upper 4 way switch at the back of the headrest up down Tilting the headrest Tilt the headrest backward forward by pushing the upper 4 way switch at the back of the headrest to the left right Backrest ti
4. A After the filling time of 10 seconds or before the filling time of 2 seconds the following appears on the display CUP FILL TIMER HYDROCOLLOID CUP FILL TIMER o Eaa HYDROCOLLOID gt An unlimited time is then set as is required for the hydro colloid function However when you activate the chair program S the last saved tumbler filling time 2 10s is always started i e nO continuous operation You can start continuous operation only with the tumbler filling key Tumbler filling with automatic sensor control Special equipment not available in all countries Functioning of the automatic sensor control With this tumbler filler the automatic sensor control rec ognizes the filling level of the tumbler When you place the tumbler beneath the tumbler filler the tumbler will be filled automatically After the preset filling level has been reached the water flow stops automatically If the tumbler is removed before the preset filling level has been reached the water flow stops immediately If required the tumbler can be refilled manually by pressing the corresponding tumbler filling key Setting the filling level You can preset the filling level of the tumbler with the knob on the base of the water unit foot end Clockwise rotation increases the filling amount 59 06 313 D 3382 52 D 3382 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions C4 CUP FILL ONS YES
5. NO Cuspidor flushing 420 BOWL FLUSH TIMER 59 06 313 D 3382 D 3382 201 01 13 02 10 Operation light tumbler filling cuspidor flushing purge 10 4 Cuspidor flushing A CAUTION e The tumbler must not be transparent e The tumbler must always be placed in the center of the area provided for it e If an empty tumbler is standing below the tumbler filler when the treatment center is switched on with the main switch the tumbler will not be filled automatically To ac tivate automatic tumbler filling remove the tumbler brief ly and then put it back again e The Mode dialog CUP FILL ON S YES NO must be set in such a way that NO flashes e Hydrocolloid connection is not possible if tumbler filling with automatic sensor control is installed When you press this key briefly the flushing function is switched ON and the cuspidor is flushed for a preset period of time When you press the key again while the cuspidor is being flushed flushing stops Only for cuspidor flushing key of the dentist ele ment Pressing this key for gt 3 seconds displays the settings dialog BOWL FLUSH TIMER You can set a flushing time between 20 and 420 sec onds in steps with the keys 53 10 Operation light tumbler filling cuspidor flushing purge Sirona Dental Systems GmbH 10 5 Purge Auto Purge function purging the water paths Operating Instructions C4 10 5 Purge Auto Purge
6. on burr drives Chip blower on burr drives Counterclockwise rotation for electric motor Instrument light ON OFF Pressing this key for some time displays the light inten sity settings dialog Mouth rinsing position chair program with last position memory function freely programma ble Chair program 0 Entry exit position freely programmable Chair programs 1 and 2 freely programmable notice The four program keys are also used for reprogramming the chair programs 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions C4 0D OPERATING LIGHT AAAA AAA IO CUP FILL TIMER PE yel BOWL FLUSH TIMER AAAA AAAA 59 06 313 D 3382 D 3382 201 01 13 02 4 Controls and functional elements 4 1 Control panel on the dentist element Additional functions light blue keys Preselection of user A or B All instruments must be in place You cannot switch between the two users after picking up an instrument Saving the instrument settings The instrument to be programmed must have been picked up X ray image viewer ON OFF For SIVISION 3 also WHITE SCREEN activation Composite key ON OFF for SIROLUX operation light reduced light intensity lt 8 000 lux for composite fillings SIROLUX operation light ON OFF for normal light intensity gt 24 000 lux Pressing this key for a while displays the light intensity setti
7. CAM being activated message box These settings will remain saved even after you switch off the PC The SIVISION monitor must also be set to PC mode Analog Port see monitor operating instructions After switching the treatment center or the PC off and on again it may be necessary to reset the monitor to PC mode 97 14 SIVISION 3 Sirona Dental Systems GmbH 14 11 SIVISION3 second monitor function without SIROCAM3 SIROCAM C Operating Instructions C4 14 11 SIVISION3 second monitor function without SIROCAM3 SIROCAM C 98 The monitor integrated in the treatment center serves as primary or secondary monitor for the externally con nected PC The following function keys of the control panels as well as foot switch functions are available for controlling PC functions e Spray e Chip blower e Electric motor CCW rotation e Instrument light e Call key if not already used for relay functions e key if not already used for relay functions e All quick setting keys 100 50 and 1 e Cursor forward if the cursor is between the spray and chip blower keys e Cursor forward if the cursor is between the S and 0 chair program keys With C foot switch cursor forward With C foot switch Actuate foot switch in direction A cursor upward All instruments must be in place when you do so as well as the function keys e X ray image viewer They can be used to control e g SIDEXIS VIDEXIS
8. Shift 4 way foot control plate With cursor control enabled Mode dialog 11 8 A to the front cursor upward B to the back cursor downward C to the left cursor to the left D to the right cursor to the right Cursor navigation along the marked path and re lease of the corresponding key function 2 Actuate left button all instruments in place Programmed movement of the chair to the mouth rinsing position S or the last treatment position ac cording to starting situation Actuate left button instrument picked up Toggling between spray ON and spray OFF or SIVISION function 3 Actuate right button all instruments in place Programmed movement of the chair to the entry exit position 0 Actuate right button instrument picked up Chip blower active for duration of actuation or SIVISION function 59 06 313 D 3382 D 3382 201 01 13 02 23 6 Foot switch Sirona Dental Systems GmbH 6 1 C foot switch Operating Instructions C4 Automatic cursor control with C foot switch A yellow diode on the dentist element indicates the posi tion of the cursor The cursor path is marked by lines 1 After you switch on the system or when the chair has reached the entry exit position 0 the cursor is 40 between the chair program keys 1 and 2 20 S amp S j 2 When you pick up an instrument or activate any of the instruments the cursor jumps to the horizontal 0 2 navigation path position between 1st and
9. assistant element 59 06 313 D 3382 12 D 3382 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions C4 O ON OO OO A 11 12 System overview C4 Cart 7 i 9 123456 Assistant element Holder 1 Mini L E D polylight or 3rd suction hose or SIROCAM 3 SIROCAM C Holder 2 SPRAYVIT in the assistant element or SIROCAM 3 SIROCAM C Holder 3 Suction handpiece Holder 4 Saliva ejector Control panel on the assistant element Rigid or swivelable cuspidor Tumbler filler Water unit with amalgam rotor disinfection system automatic separator wet suction Patient chair option folding armrest Holder 1 SPRAYVIT in the dentist element Holder 2 and 3 Electric motor highspeed hand piece burr drives 59 06 313 D 3382 D 3382 201 01 13 02 3 System versions 3 2 System overview C4 Cart 10 11 12 1314 16 17 13 14 15 16 17 18 19 20 21 22 23 Holder 4 3rd electric motor highspeed handpiece burr drive or SIROSONIC L scaler or Mini L E D polylight Holder 5 4th burr drive only highspeed handpiece or SIROSONIC L or Mini L E D polylight or SIROCAM 3 SIROCAM C Additional instrument holder only for SIROCAM 3 SIROCAM C Control panel on the dentist element C4 Cart dentist element Locking brake on the assistant element Unit main switch Flat headrest or manually adjustable headrest or motorized headrest 4 way foot control of chair Unit foot switch C or
10. cccccceceeeeeeeseseeeeeeseeeeeeeseeseeeeeaeeeeesaseeessaaees 62 iA Mode FURGE MME SEC asnu Koo toate ase ste seeia races Oh eek ate E oeeeaaaeae 62 VitS Mode PRESSURE PSI BAR cscs tcctcsn aintctnapeneennartadea te utuciotenstaieeaaeeceatiteneniomest 63 11 16 Mode SPRACHE LANGUAGE ENG D 1 F B eeccccccseeeeeeeeeeeeeseeeseeeeeseseeeeaaaeeeeesaaeeees 63 11 17 Mode POLYLUX WITH CFS YES N vevecsssecceostceseesecat wns seacesineescdanseicessaveteaoeeseesassanlavees ecient 63 11 18 Mode SUCTION WITH CFS YES NO vcs ckeete ice Rhee chee ede RG 63 tago Mode WHITESGREEN YES INO sete oes casted caxiegataiabeeeeceeaa ates cise N 64 11 20 Mode A B VIDEO MODE ON QF Fiz 4s whi cue ert cre a a hele 64 t121 Mode BLOW OUT SPRAY seinan ee Le ee ee e 64 ASSISTANT CIEMEMNE scccteceercteedscssces ce eceswsvexessswessivesexteucevarsacsneeatecunadtacawetareanancetdventewsassiess 65 127 PXSSISTANIE elemenia suena etanteasintc esis E 65 12 2 Suction handpieces on the assistant ClEMEN cccccceeeeececeseeeeeceeeeeeceaeeeeeseeeeeeseaeeeeseaeeeeesansees 66 12 3 SPRAYVIT on the assistant element cccccseeeccceeeeeeeeeeeeeeeceeeeeeeseeeeeeeseeeeecsaaeeeeesaaeeeessenseeessaees 67 12 4 Satelec Mini L E D curing light on the assistant element ccceeeeeeceseeeeeeceeseeeeeeeeeeeeaaneeeeeaeeees 67 Water Unit seca ieee sao cee a Eaa aaa aaas ea aeaa Eai 68 13 1 Swivelable cuspidor alternative equipment c
11. functions such as Tile Next Image Full Frame Zoom In Zoom Out Rotate Image but also other PC applica tions The factory settings as well as the configuration proce dure are described in the Installation manual for PC software REF 59 11 719 Operator s Manual 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 15 CEREC Chairline Option Operating Instructions C4 15 1 CEREC Chairline CEREC Chairline Option CEREC Chairline CEREC Chairline is used for 3 dimensional acquisition of the preparation the occlusion and the antagonist For details on its function and operation please refer to the CEREC Chairline Operating Instructions REF 60 46 028 and Operator Manual REF 59 56 458 CEREC Chairline foot switch A Bluetooth radio module for transmitting the CEREC foot switch signal to the CEREC PC is integrated in the CEREC Chairline foot switch For details refer to Chapter 5 Model designation of radio module Blue RS I Stollmann Co Frequency 2 4GHz 2 4835GHz ISM band Bluetooth class 2 Range approx 10m Approvals CE conformity according to R amp TTE Directive 1999 5 EC Part 15 of the FCC Rules RSS 210 of Industry Canada 59 06 313 D 3382 D 3382 201 01 13 02 99 16 Extra equipment and accessories Sirona Dental Systems GmbH 16 1 Media block on the patient chair Operating Instructions C4 Extra equipment and accessories Media block on the patient chair Extra equ
12. 1 The message ENDO appears on the display For safety reasons we recommend that you program the set value for endodontics Otherwise the previously programmed value becomes active again when the instrument is placed back in its holder in the meantime A CAUTION When you exceed the value of 4 in endodontic therapy temperature damage and needle breakages can occur 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions C4 9 6 SPRAYVIT 9 Dentist element and instrument functions 9 6 SPRAYVIT If the SPRAYVIT is the only instrument that has been picked up you may switch the instrument light on or off You can also set the brightness The instrument light switches on when you activate the SPRAYVIT if preset The instrument light switches off after a time lag of 10s when the SPRAYVIT is no longer activated When you place the SPRAYVIT back in its holder the instrument light switches off immediately If the SPRAYVIT is activated together with another instrument the SPRAYVIT light is not switched on A DANGER After changing hoses press the water button of the SPRAYVIT repeatedly until water comes out Only then can you begin treatment 9 7 Saving the instrument programs 40000 40 gt 0i 59 06 313 D 3382 D 3382 201 01 13 02 The factory set instrument programs can be changed individually by user A and user B Select the corresponding user i e A or
13. B pick up an instrument and set it according to your wishes Example for electric motor e 40 000 rpm e CW rotation e with cooling spray e with instrument light To save the settings press key A B for some time approx 3 s An audible signal sounds These settings are then activated whenever the instrument is picked up You cannot switch between the two users after pick ing up an instrument Q vortice If counterclockwise rotation was programmed the motor is reset to clockwise rotation after you switch the treat ment center off and back on 43 9 Dentist element and instrument functions Sirona Dental Systems GmbH 9 8 Placing treatment instruments in their holders Operating Instructions C4 Placing treatment instruments in their holders A ball stopper for an unoccupied instrument holder comes with the dentist element Plug the ball stopper 1 into the unoccupied instrument holder to prevent a treatment instrument from being placed inadvertently in this holder To block further unoccupied instrument holders you can order more ball stoppers REF 58 99 575 59 06 313 D 3382 44 D 3382 201 01 13 02 Sirona Dental Systems GmbH 9 Dentist element and instrument functions Operating Instructions C4 9 9 Surgery with saline solution NaCl Surgery with saline solution NaCl Preparation of the unit e Hook the NaCl bottle 1 in place e Attach the peristaltic pump hose set 2 e Push the short
14. C Foot button for SIROCAM 3 SIROCAM Con the assistant element 13 3 System versions 3 3 System overview C4 Cabinet Sl a 14 System overview C4 Cabinet 123456 78 9 10 hae SS CD z 11 V DIERE SSN EZ 12 A R a CULTUL if 5 fii H p 7 Z 7 E 23 Assistant element Holder 1 Mini L E D polylight or 3rd suction hose or SIROCAM 3 SIROCAM C Holder 2 SPRAYVIT in the assistant element or SIROCAM 3 SIROCAM C Holder 3 Suction handpiece Holder 4 Saliva ejector Control panel on the assistant element Rigid or swivelable cuspidor Tumbler filler Water unit with amalgam rotor disinfection system automatic separator wet suction Patient chair option folding armrest Holder 1 SPRAYVIT in the dentist element Holder 2 and 3 Electric motor highspeed hand piece burr drives 13 14 15 16 17 18 19 20 21 22 23 Sirona Dental Systems GmbH Operating Instructions C4 Holder 4 3rd electric motor highspeed handpiece burr drive or SIROSONIC L scaler or Mini L E D polylight Holder 5 4th burr drive only highspeed handpiece or SIROSONIC L or Mini L E D polylight or SIROCAM 3 SIROCAM C Additional instrument holder only for SIROCAM 3 SIROCAM C Control panel on the dentist element C4 Cabinet dentist element Locking brake on the assistant element Unit main switch Flat headrest or manually adjustable headrest
15. Extra equipment If a folding armrest is attached to the patient chair it can be folded up or down by pressing the two buttons on the lower end of the armrest at the same time When it is folded up the armrest locks automatically into its position for use 16 5 Hydrocolloid coolant supply Extra equipment If you want to work with a hydrocolloid coolant supply you can obtain an adapter Order No 33 15 814 free of charge with the enclosed voucher Please state your address and the serial number of the chair see Installation Report Warranty Passport To connect the adapter to the cuspidor proceed as fol lows Pull out the tumbler outlet 1 turning it slightly at the same time and plug the adapter 2 into the self closing valve until it snaps into place Press the locking clip 3 before pulling out the connecting piece For water cooling press the tumbler filling key The tum bler filling time must be set to unlimited HYDROCOL LOID operation for this purpose see section 10 2 Tum bler filling on page 51 A CAUTION During the hydrocolloid procedure the disinfection of the tumbler water and the instruments is switched off In order to rinse residual non disinfected water out of the lines please push the button for TUMBLER FILLING one time before refilling the tumbler 59 06 313 D 3382 102 D 3382 201 01 13 02 Sirona Dental Systems GmbH 16 Extra equipment and accessories Operating In
16. away the maintenance prompt automatically appears on the display each time the unit is switched on You should then contact your local dental depot imme MAINTENANCE i IN 30 DAYS diately for a maintenance appointment After this date has expired the following message is dis played MAINTENANCE REQUIRED The steps to be performed as well as the parts which must be replaced are specified in the document Main tenance Certificate An overview of the inspection and maintenance work performed is additionally recorded by the service engi neer in the Installation Report Warranty Passport This document is part of the Maintenance Manual 59 06 313 D 3382 106 D 3382 201 01 13 02 Sirona Dental Systems GmbH 17 Maintenance Operating Instructions C4 17 3 Safety checks Safety checks Medical equipment is designed in such a way that the first occurrence of a fault does not create a hazard to the safety of patients users or other persons Hence it is important to detect such faults before a second fault occurs which might then lead to safety hazards For that reason it is essential to perform safety tests every 2 years which aim particularly at detecting electri cal faults e g isolation defects This is done by an authorized service engineer from your dental depot most practically together with the work to be performed according to section 17 2 The check includes a visual inspection as well as mea
17. been activated factory setting the SIROCAM 3 SIROCAM C camera automatically switches to the PC mode The SIROCAM 3 SIROCAM C camera remains in PC mode until one of the following occurs video mode is activated on the PC the camera is disconnected from the treatment center or the treatment center is switched off 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions C4 SIUCOM About Siucom ee SIROCAM being deactivate Help PC_MODE_OWN PC_MOOGE_OFF white image monitor seed hose About Siucom SIUCOH E Settings z Help SIROCAM being activated PC_MODE_ON PC_MODE_OFF white image monitor selection ase aa 10 06 59 06 313 D 3382 D 3382 201 01 13 02 14 SIVISION3 14 10 Switching between VIDEO mode and PC mode Switching to video mode Right click the Siucom icon in the Systray usually in the lower right corner of the screen In the Siucom popup menu which then opens click PC _MODE_OFF Confirm by clicking OK in the SIROCAM being deactivate message box These settings will remain saved even after you switch off the PC The SIVISION monitor must also be set to video mode S Video Port see monitor operating instructions Switching to PC mode Right click the Siucom icon in the Systray usually in the lower right corner of the screen In the Siucom popup menu which then opens click PC_MODE_ON Confirm by clicking OK in the SIRO
18. blower keys in the instrument block when you swing the foot switch to the right D 3 After you have placed the instrument in its holder the cursor jumps back to its position between the chair program keys S and 0 Activate the desired chair program 1 or 2 The chair moves to the programmed treatment position Move the dentist element by hand to the desired treat ment position Use the handle 1 on the dentist element to do this The dentist element can be fixed by the service engineer at a height which is convenient for you 59 06 313 D 3382 26 D 3382 201 01 13 02 Sirona Dental Systems GmbH 7 Program selection Operating Instructions C4 7 1 Safety Program selection 7 1 Safety A CAUTION The patient s arms and legs must be resting on the chair upholstery during the program run A CAUTION Make sure that no obstacles e g window wings draw ers devices extend into the movement range i Safety stop A built in safety circuit stops the chair movement in the following situations e The toeboard collides with an obstacle e The backrest collides with an obstacle e The motorized headrest if available collides with an obstacle e The swivelable cuspidor is swiveled in during chair movement e The assistant element is pushed upward or down ward by an obstacle At the same time a double beep signal sounds The chair then moves automatically a little upward until the obstac
19. function purging the water paths PURGE function only for dentist element The purge function enables you to flush the water paths To do this press the quick setting key 1 gt 3 s when all instruments are in their holders You will be prompted to choose between PURGE A APURGE and SANITATION Select PURGE with the or key PURGE must flash SELECT MODE PURGE APURGE SAN If you press quick setting key 1 briefly lt 3 s the follow A ing prompt will appear if all instruments are in their hold ers SELECT ITEMS SELECT ITEMS FOR PURGING FOR PURGING Pick up the instruments you want to flush and hold them above the cuspidor The maximum water flow must be set on the instru ments Press quick setting key 1 again lt 3 s the instruments are then purged one after the other The purging time in seconds set previously in the Mode dialog 11 14 runs down for each instrument individu ally An audible signal sounds after the last instrument has been flushed Finally place the instruments back in their holders 1 The SANITATION function is described in the instructions Care and Cleaning by the Practice Team 59 06 313 D 3382 54 D 3382 201 01 13 02 Sirona Dental Systems GmbH 10 Operation light tumbler filling cuspidor flushing purge Operating Instructions C4 10 5 Purge Auto Purge function purging the water paths Auto Purge APURGE function The Auto Purge function
20. handpiece you can switch the NaCl pump ON OFF by pressing the spray key or by stepping on the left button on the C foot switch or by swinging the pedal plate to the left on the C foot switch 59 06 313 D 3382 D 3382 201 01 13 02 45 9 Dentist element and instrument functions Sirona Dental Systems GmbH 9 10 Satelec Mini L E D curing light Operating Instructions C4 When the green LED of the key lights up the NaCl pump is ON NACL appears on the display in the instrument dialog of the instrument to which the NaCl pump has been assigned Satelec Mini L E D curing light Safety information A CAUTION Always use the glare shield The light beams emitted by this instrument may be haz ardous and may never be directed to the eyes of any per son even if this person wears goggles with protective lenses The light may be directed exclusively to the treat ment area in the oral cavity L E D beam exit aperture A CAUTION Do not stare into the beam path with the glass rod re moved Class 2M laser product Viewing the L E D beam exit aperture with certain opti cal instruments e g a magnifying lens within a distance of 100mm may constitute an eye hazard L E D RADIATION DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS CLASS 2M LASER PRODUCT P lt 1 mW A 420nm 480nm IEC 60825 1 Ed 1 2 59 06 313 D 3382 46 D 3382 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions
21. in Canada FabrikstraBe 31 Sirona Dental Systems LLC Sirona Canada Order No 59 06 313 D 3382 64625 Bensheim 4835 Sirona Drive Suite 100 3250 Ridgeway Drive Unit 5 Germany Charlotte NC 28273 Mississauga Ontario L5L 5Y6 WWW Sirona com USA Canada
22. in the same way as for Mode DAY MON YEAR l 21 JUN 00 TIME HOURS MIN in the order of year month day The date is not displayed during operation of the unit It is required only for internal treatment center functions e g for service information Mode FOOT CONTROL NORMAL EXTENDED Switching the cursor on off If you want to control the treatment center only manually you can switch the cursor control off FOOT CONTROL The then differing functions of the relevant foot switch NORMAL EXTENDED are described in the Foot switch section This setting can be chosen individually for user A or B 11 9 Mode BOWL FLUSH ON S YES NO Cuspidor flushing with chair program S A If you want the cuspidor flushing to switch on in program S of the treatment chair BOWL FLUSH ON S S ose Pe 10 Mode CUP FILL ON S YES NO Tumbler filling function with chair program S If you want the tumbler to be filled in program S of the treatment chair CUP FILL ON S i amaD 59 06 313 D 3382 D 3382 201 01 13 02 59 11 Basic treatment center settings in the Mode dialog 11 11 Mode WHITE BALANCE only with an integrated SIROCAM 3 Sirona Dental Systems GmbH Operating Instructions C4 Mode WHITE BALANCE only with an integrated SIROCAM 3 TAKE VCAM WHITE BALANCE HOME USER EXIT 60 White balance for the SIROCAM 3 This Mode dialog is only displayed in connec
23. mode This mode is selected by pressing the function button The light operates at full power in pulsed mode it emits radiation in 10 consecutive light pulses of 1s each Between the individual pulses there is a 250 ms break LED 4 3 shows your selection 4 4 Soft start mode This mode is selected by pressing the function button The soft start mode provides e A10 second soft start from O to 1100 mW cm or from 0 to 2000 mW cm with the optional booster light guide dia 5 5 mm e Full power during 10 seconds LED 4 4 shows your selection Handling After you switch on the treatment center the Mini L E D is by default in the quick curing mode 4 2 If you change the operating mode of the Mini L E D while the treatment center is in operation the new mode remains valid even after placing the Mini L E D in its holder After you have selected a mode the Mini L E D is ready for operation Position the light guide as close as possible to the com posite material surface you want to photopolymerize Make sure that the light guide never touches the material to be cured as this may cause damage to the light guide and reduce its effectiveness e Never work without the glare shield 5 e Never look into the light which is reflected by the tooth surface 49 9 Dentist element and instrument functions 9 10 Satelec Mini L E D curing light 50 Sirona Dental Systems G
24. or motorized headrest 4 way foot control of chair Unit foot switch C or C Foot button for SIROCAM 3 SIROCAM Con the assistant element 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions C4 4 Controls and functional elements 4 1 Control panel on the dentist element 4 Controls and functional elements 4 1 Control panel on the dentist element Control panel C4 A AMALG DESINF We phy RPM PhP Ly 59 06 313 D 3382 D 3382 201 01 13 02 4o000 System status indication display and Mode key AMALG appears when the amalgam rotor needs to be replaced DESINF is flashing when DENTOSEPT P must be refilled A appears when user A is selected B appears when user B is selected Mode key with keys for programming basic set tings In addition to the settings in the Mode dialog the follow ing direct settings can be made with the keys e Intensity of the instrument lights e Intensity of the operation light e Tumbler filling time e Cuspidor flushing time 15 4 Controls and functional elements 4 1 Control panel on the dentist element 16 rpm x 1000 ikk INSTR LIGHT EEREEECCCEEEENN Sirona Dental Systems GmbH Operating Instructions C4 Main functions dark blue keys Quick setting keys for instrument intensity and speed for electric motors and SIROSONIC L ultrasonic scaler Spray ON OFF
25. surements of the protective ground wire connections and the equivalent leakage currents The inspections and measurements to be performed are specified in the Maintenance Manual The measured values must be documented there by the service engi neer Safety tests must also be performed and documented during initial startup after extensions upgrades con version of your treatment center and after repair work which might affect the electrical safety of the system Q vortice The treatment center must not be operated if it has failed to pass the safety tests Maintenance Manual Keep this document near your treatment center Any inspection and maintenance work as well as all safety tests are documented by the service engineer in the Maintenance Manual We recommend that the user always keep the documen tation in the chapter Reporting of incidents to author ities manufacturers up to date regardless of any legal requirements 59 06 313 D 3382 D 3382 201 01 13 02 107 17 Maintenance Sirona Dental Systems GmbH 17 4 Maintenance Manual Operating Instructions C4 59 06 313 D 3382 108 D 3382 201 01 13 02 We reserve the right to make any alterations which may be required due to technical improvements Sirona Dental Systems GmbH 2001 2006 Sprache englisch Printed in Germany D 3382 201 01 13 02 06 2007 A Nr 108 389 Imprim en Allemagne SSS SS SSS SSS EEE SS eae Sirona Dental Systems GmbH in the USA
26. switch you activate the chip blower for a picked up instrument by stepping on the right foot switch button 4 As long as you keep the button pressed an air jet escapes from the nozzle of the burr instrument C foot switch With a C foot switch the cursor jumps directly between the spray and chip blower keys when you pick up an instrument When you swing the foot switch to the right D an air jet escapes from the nozzle of the burr instru ment for the duration of actuation When the chip blower is active the green LED in the key is illuminated Instrument light ON OFF With this key on the dentist element control panel you preset the instrument light for the picked up instru ment If light ON is preset the green LED in the key is illumi nated When you press the key for more than 3 seconds the A INSTR LIGHT settings dialog is displayed Here you z can set a light intensity between 60 and 100 with the keys INSTR LIGHT TU notice If more than one instrument is picked up only the instru lt a gt ment which was picked up first is operative 59 06 313 D 3382 D 3382 201 01 13 02 39 9 Dentist element and instrument functions 9 3 Electric motor Electric motor 4pooo 40 20 0 2 rpm x 1000 40 Sirona Dental Systems GmbH Operating Instructions C4 Speed setting When you pick up an electric motor the programmed speed of the motor in RPM revolutions p
27. the foot button The image number of the selected image appears in the upper right corner of the image e When you briefly press the camera button the se lected image is displayed on the screen as a single STILL IMAGE When you press the button again the view changes to the QUAD IMAGE etc e When you briefly touch the foot button while the se lected single STILL IMAGE is displayed on the screen a LIVE IMAGE appears It can be frozen by touching the foot button again and overwrites the se lected single STILL IMAGE at this memory location 59 06 313 D 3382 D 3382 201 01 13 02 91 14 SIVISION 3 Sirona Dental Systems GmbH 14 8 SIROCAM 3 SIROCAM C integrated in the assistant element video Operating Instructions C4 DELETING ALL IMAGES from the camera memory With a QUAD IMAGE displayed and the camera picked up e Press and hold down the foot button and then press the camera button e ALIVE IMAGE appears 59 06 313 D 3382 92 D 3382 201 01 13 02 Sirona Dental Systems GmbH 14 SIVISION3 Operating Instructions C4 14 8 SIROCAM 3 SIROCAM C integrated in the assistant element video Placing back the camera e IfaLIVE IMAGE was displayed a BLACK SCREEN appears e ASTILL IMAGE or a QUAD IMAGE remains dis played WHITE SCREEN To activate a WHITE SCREEN the camera must be placed in its holder When you briefly press the camera button now a WHITE SCREEN is displayed on the monitor When y
28. the valve 2 59 06 313 D 3382 68 D 3382 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions C4 Amalgam rotor AMALG ypooo 59 06 313 D 3382 D 3382 201 01 13 02 13 Water unit 13 3 Amalgam rotor The message AMALG appears on the display when the amalgam rotor needs replacement i e when having reached a filling level of 95 see instructions Care and Cleaning by the Practice Team A continuous sound indicates that the rotor is full and no longer functioning properly An intermittent sound indicates a system error The water supply is interrupted Please contact your service engineer notice The rotor inside the amalgam separator must be re placed at least once a year even if the AMALG message does not light up Otherwise unpleasant odors can de velop 69 13 Water unit 13 4 Disinfection system optional Disinfection system optional A A 4 W Ji P o I l I af WyN Yves DESINF 4ygooo 70 Sirona Dental Systems GmbH Operating Instructions C4 When the message DESINF flashes on the dentist ele ment display during treatment you should refill 1 liter of DENTOSEPT P at the latest after the end of the treat ment day When the message flashes it is not possible to perform sanitation Remove the cover behind the cuspidor and fill in 1 liter of DENTOSEPT P The filler trough should always be kept clean Always make sure t
29. was in place this view is retained e ifa BLACK SCREEN was displayed while the cam era was in place a LIVE IMAGE appears e IfaWHITE SCREEN was displayed while the cam era was in place the view preceding the WHITE SCREEN i e a LIVE STILL or QUAD IMAGE re appears 59 06 313 D 3382 D 3382 201 01 13 02 89 14 SIVISION 3 Sirona Dental Systems GmbH 14 8 SIROCAM 3 SIROCAM C integrated in the assistant element video Operating Instructions C4 Vee GENERATING STILL IMAGES e Briefly touch the foot button when the camera has been picked up The image number appears in the upper right corner of the image e When you touch the foot button again briefly a LIVE IMAGE reappears e To freeze the next STILL IMAGE briefly touch the foot button again Image number Il appears in the upper right corner of the image e Use the same method to generate STILL IMAGE III and III e When you briefly touch the foot button after STILL IMAGE Ilill has appeared the QUAD IMAGE the 4 single images in a tiled view is displayed on the screen 59 06 313 D 3382 90 D 3382 201 01 13 02 Sirona Dental Systems GmbH 14 SIVISION3 Operating Instructions C4 14 8 SIROCAM 3 SIROCAM C integrated in the assistant element video Nae SELECTING OVERWRITING IMAGES e When a QUAD IMAGE is displayed with the camera picked up you can select a specific image from the QUAD IMAGE by briefly touching
30. 2nd row of rpm x 1000 keys in the instrument block 3 After you have placed the instrument in its holder the cursor jumps back to its position between the chair program keys 1 and 2 CEREC Chairline foot switch This foot switch includes all of the functions of the Ct foot switch It also features an additional pedal for operation of the CEREC Chairline For details please refer to the CEREC Chairline Opera ting Instructions REF 60 46 028 59 06 313 D 3382 24 D 3382 201 01 13 02 Sirona Dental Systems GmbH 6 Footswitch Operating Instructions C4 6 2 C foot switch 6 2 C foot switch This foot switch enables hands free operation by con trolling all functions with the entire pedal surface How ever it is also possible to control the unit manually with the keys For cursor navigation place your foot fully on the pedal surface Functions factory settings Q norice The foot switch functions A and B can be reversed by the service engineer upon request With cursor control enabled Mode dialog 11 8 Actuate foot switch in direction A cursor upward Actuate foot switch in direction B cursor downward Swing foot switch to the left C cursor to the left Swing foot switch to the right D cursor to the right Cursor navigation along the marked path and release of the corresponding key function Instrument start 40 The cursor must be between the spray and the chip 20 blower key Actuat
31. 3 14 10 Switching between VIDEO mode and PC mode EE crc CUCU mm 0 Sirona Dental Systems GmbH Operating Instructions C4 USING THE CAMERA BUTTON AND THE FOOT BUT TON AS FUNCTION KEYS The camera must be placed in its holder Further functions such as WHITE SCREEN BLACK SCREEN or the SIDEXIS VIDEXIS functions Tile Next Image Full Frame Zoom In Zoom Out Rotate Image as well as other PC controls can be assigned as desired to the camera button and the foot button The factory settings as well as the configuration proce dure are described in the Installation manual for PC software REF 59 11 719 Operator s Manual 14 10 Switching between VIDEO mode and PC mode Video mode PC mode Systray lt _ ___ _ 96 Only with SIROCAM 3 SIROCAM C in the assistant element and a connected PC The system can be used in two operating modes e Video mode The video image from the camera is directly dis played on the SIVISION monitor e PC mode The video image is processed on the PC The SIVI SION monitor shows the PC user interface To toggle between the two modes the popup menu of the Siucom program on the PC is used The SIROCAM 3 SIROCAM C camera is always in video mode after the treatment center is switched on or the camera is connected to the assistant element When the Siucom program is running executes simul taneously with SIDEXIS VIDEXIS and the entry PC_MODE_ON has
32. 3 on the camera Button released close range 5 15mm Button pressed far range from 15mm to smile line 59 06 313 D 3382 76 D 3382 201 01 13 02 Sirona Dental Systems GmbH 14 SIVISION3 Operating Instructions C4 14 5 Operating modes of SIVISION 3 Hygienic protective covers for SIROCAM C Hygienic protective covers are available for the camera They can be ordered under REF 59 14 705 Package size 500 pcs How to use the hygienic protective covers 1 Hold the hygienic protective cover with its paper side face down and insert the camera with the optical system downward into the cover 2 Pull off the upper protective foil with the blue stripe 3 Then pull off the backing paper 4 Finally stretch the hygienic protective cover over the camera from front to rear A CAUTION For optimum image quality there must not be any folds in the transparent area of the cover above the lens window A CAUTION Use only the hygienic protective covers offered by Siro na Prior to each application on a new patient the camera must be covered with a new hygienic protective cover Operating modes of SIVISION 3 SIVISION 3 with SIROCAM 3 or SIROCAM C can be used basically in two different operating modes e VIDEO mode The camera image is directly displayed on the SIVISION monitor The quad image memory of the camera is activated e PC mode The camera image is first processed on the PC and then the image ge
33. 5 SIROSONIC L scaler 40 20 0 2 rpm x 1000 ENDO 42 Sirona Dental Systems GmbH Operating Instructions C4 You set the intensity in increments of 1 50 100 by pressing the quick setting keys briefly lt 0 5s lf the cursor is in the intensity setting block you can set the intensity also with the foot switch using the forward backward cursor When you set the intensity with the cursor the displayed intensity value is incremented decremented in steps of 25 when you actuate the foot switch briefly lt 1s for ward or backward At the values of 1 50 and 100 the green LED in the cor responding key lights up When you press and hold down a key for gt 0 5s you adjust the intensity in predefined increments Increments of 1 from 1 4 Increments of 5 from 10 100 When you press a key whose value is gt the value shown on the display for gt 0 5s the intensity is increased When you press a key whose value is less than the value shown on the display for gt 0 5s the intensity is reduced When you actuate the foot switch forward or backward for gt 0 5s the displayed intensity value is increased or reduced in predefined increments When you set intermediate values the green key LED does not light up The cooling water flow is always switched on automati Cally Endodontics setting An intensity range of 1 4 is provided for endodontics mode It can be adjusted in increments of
34. C Influence on cardiac pacemakers Treatment of highly immunosuppressed patients Quality of water air supply Water quality compliance Highlighting of warning and safety information Sirona Dental Systems GmbH Operating Instructions C4 The C4 complies with the requirements of IEC 60601 1 2 2001 Medical electrical equipment is subject to special pre cautionary measures with regard to EMC It must be installed and operated in compliance with the specifica tions provided in the document Installation Require ments Portable and mobile RF communication systems may interfere with medical electrical equipment For this rea son the use of mobile radio telephones in practice or hospital environments must be prohibited With video systems Electromagnetic disturbances in the environment of the C4 may result in reduced image quality In such cases it is advisable to repeat the exposure before saving the image In case of line voltage drops image data stored in the video camera may be lost Place down the camera and repeat the exposure Image artifacts may possibly occur as a result of radio frequency interference caused by the transmitters of e g radio services or radio amateurs The workstation includes strong magnets which can affect cardiac pacemakers of patients users and techni cal personnel Therefore pease pay attention to the safety information on pages 7 and 57 Highly immunosuppressed patie
35. C4 59 06 313 D 3382 D 3382 201 01 13 02 9 Dentist element and instrument functions 9 10 Satelec Mini L E D curing light Additional safety information Any condensation occurring in the handpiece of the Mini L E D may cause impairments e g fogging of the L E D If the handpiece is moved from a cool environ ment to a warm room always wait for it to reach room temperature before putting it into operation Curing lights must not be used on persons who are suf fering from or have in the past been afflicted by photobi ological reactions including solar urticaria and erythro poetic porphyria Nor should they be used on persons currently being treated with any medicine which increases one s sensitivity to light including methox salene and chlorotetracycline Any persons who have in the past suffered from retinal or eye lens disorders or have undergone eye surgery especially for gray cataracts must consult their medical eye specialist before using the light or undergoing treat ment with the Mini L E D Caution is advisable even if the patient gives his or her consent since the light intensity can cause accidents It is especially advisable to always wear appropriate protective goggles UV filter Installation 1 Connect the supply cable to the treatment center 2 Screw the handpiece on 3 Attach the sterilized light guide to the handpiece Make sure to insert the light guide correctly The light g
36. IME 120 SEC r Mode gt onds for each instrument with the keys for the purge function see page 54 62 Free function key as button or switch In this mode you can preset whether you want to use the free function key as a button or as a switch see page 17 Setting the purge time for flushing the water paths Only for dentist element You can preset a purging time between 60 and 120 sec 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 11 Basic treatment center settings in the Mode dialog Operating Instructions C4 11 15 Mode PRESSURE PSI BAR E A A R 11 19 Mode PRESSURE PSI BAR Indication of pressure in PSI or bar A In this mode you can select whether you want the driv ing air pressure of the highspeed handpiece to be dis PRESSURE played in PSI or bar PSI BAR 11 16 Mode SPRACHE LANGUAGE ENG D I F E Language setting A In this mode you can select the desired display lan guage ENG English D German l Italian F French SPRACHE LANGUAGE and E Spanish ENG D I F E Mode lt b gt i l 1 17 Mode POLYLUX WITH CFS YES N This dialog has no function in connection with the Mini A L E D curing light Set NO POLYLUX WITH CFS SD ode od 5 a i i 11 18 Mode SUCTION WITH CFS YES NO Interrupting or restarting the suction flow with A the 4 way foot control If YES is flash
37. LING BETWEEN QUAD IMAGE AND SIN GLE IMAGE Chip blower key on the control panel Manually or by cursor using the foot switch with instru ments in place or camera picked up With Ct foot switch also right foot switch button only with camera picked up Toggling between a QUAD IMAGE and a SINGLE IMAGE When you switch to a SINGLE IMAGE the image previ ously selected in the QUAD IMAGE is displayed CLEARING THE MEMORY Electric motor CCW rotation key on the control panel Only with the camera picked up and activated manually or by cursor using the foot switch Clears all image memory locations of the camera The LIVE IMAGE mode for image I appears 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 14 SIVISION3 Operating Instructions C4 14 6 SIROCAM 3 SIROCAM C integrated in the dentist element video Placing back the camera e IfaLIVE IMAGE was displayed a BLACK SCREEN appears e A STILL IMAGE or QUAD IMAGE BLACK SCREEN or WHITE SCREEN remain displayed SWITCHING TO THE NEXT IMAGE WITH THE CUR SOR Special function only with cursor The cursor is in the chair programs key block level 1 With the C foot switch 4 way foot control plate forward With the C foot switch Actuate the foot switch in direction A cursor upward e Switching through the images STILL IMAGE I STILL IMAGE Il STILL IMAGE III STILL IMAGE III QUAD IMAGE STILL IMAGE I
38. ON or OFF using the illustrated key on the dentist or assistant element control panel To view intraoral dental images the anti glare film 1 must first be attached with two clips Then fasten the intraoral dental images with the third clip over the cut out 59 06 313 D 3382 D 3382 201 01 13 02 105 17 Maintenance Sirona Dental Systems GmbH Operating Instructions C4 Maintenance Despite the outstanding quality of your treatment center it is necessary to perform inspections and preventive maintenance as well as safety tests at predetermined intervals in order to ensure its operational safety These events are documented in the Maintenance Man ual Care and cleaning is done by the practice team For details please refer to the following sections Care and cleaning by the practice team The practice team is responsible for regular cleaning and care of the treatment center with the aim of minimiz ing the risk of contamination for patients and users The work to be performed is specified in the document Care and Cleaning by the Practice Team Inspection and maintenance In order to guarantee the operational safety and reliabil ity of your treatment center and to avoid damage due to natural wear yearly inspection and maintenance must be performed on your treatment center This is done by an authorized service engineer from your dental depot As soon as the next maintenance date is less than 30 A days
39. STILL IMAGE Il 59 06 313 D 3382 D 3382 201 01 13 02 83 14 SIVISION 3 14 6 SIROCAM 3 SIROCAM C integrated in the dentist element video WHITESCREEN YES NO 84 Sirona Dental Systems GmbH Operating Instructions C4 WHITE SCREEN X ray image viewer ON OFF key on the control panel e Switch X ray image viewer or WHITE SCREEN on the SIVISION monitor ON OFF Presetting possible in the Mode menu 11 19 e Only X ray image viewer ON OFF if NO flashes or e X ray image viewer and WHITE SCREEN on the SIVISION monitor ON OFF if YES flashes notice WHITESCREEN NO should be selected if an X ray im age viewer is installed If no X ray image viewer is in stalled select WHITESCREEN YES BLACK SCREEN 100 quick setting key on the control panel Manually or by cursor using the foot switch with instru ments in place or camera picked up Cursor forward if the cursor LED next to the quick setting keys lights up e Toggling between any view and a BLACK SCREEN e The previous view reappears when you press this key again 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 14 SIVISION3 Operating Instructions C4 14 7 SIROCAM 3 SIROCAM C integrated in the dentist element PC 14 7 SIROCAM 3 SIROCAM C integrated in the dentist element PC Operation in PC mode using a PC connection and SIDEXIS VIDEXIS The monitor is controlled by the PC in this case The functional scop
40. antee the operational safety and reli ability of your treatment center and to avoid damage due to natural wear you as the system owner must have your system checked through regularly by an authorized service engineer from your dental depot Furthermore safety checks must be performed Please contact your dental depot to obtain a mainte nance offer For details please refer to chapter 17 Maintenance on page 106 When dismantling and reassembling the system pro ceed according to the installation instructions for new installation in order to guarantee its functioning and sta bility 1 Warning and safety information Disposal 10 Sirona Dental Systems GmbH Operating Instructions C4 Please observe the disposal regulations applicable in your country Within the European Economic Area this product is sub ject to Directive 2002 96 EC as well as the correspond ing national laws This directive requires environmentally sound recycling disposal of the product The product must not be disposed of as domestic refuse Please contact your dealer if final disposal of your prod uct is required 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions C4 2 Technical description Technical description Model designation Power supply Nominal current Main unit fuse Operating conditions Transport and storage conditions Protection class Degree of protection agains
41. ard e with instruments in place or camera picked up e Call key e and key if not already used for relay functions The factory settings as well as the configuration proce dure are described in the Installation manual for PC software REF 59 11 719 Operator s Manual 59 06 313 D 3382 86 D 3382 201 01 13 02 Sirona Dental Systems GmbH 14 SIVISION3 Operating Instructions C4 14 7 SIROCAM 3 SIROCAM C integrated in the dentist element PC SAVING AN IMAGE Key example Spray ON OFF key on the control panel For this purpose a patient must be registered in SIDEXIS VIDEXIS Manually or by cursor using the foot switch with instru ments in place or camera picked up With C foot switch also left foot switch button only with camera picked up e Save the STILL IMAGE With the camera picked up a LIVE IMAGE appears Placing back the camera e The LIVE IMAGE window closes The displayed STILL IMAGE or any saved images remain open 59 06 313 D 3382 D 3382 201 01 13 02 87 14 SIVISION 3 Sirona Dental Systems GmbH 14 7 SIROCAM 3 SIROCAM C integrated in the dentist element PC Operating Instructions C4 WHITE SCREEN X ray image viewer ON OFF key on the control panel e Switch X ray image viewer or WHITE SCREEN on the SIVISION monitor ON OFF Presetting possible in the Mode menu 11 19 only X ray image viewer ON OFF if NO flashes or X ray image viewer and WHITE SCREEN o
42. bles you to adjust the patient s head in a way that optimally supports viewing of areas of the mouth which are difficult to access Adjustment of hyperextension Mandibular position The mandibular position can be set by pulling the oper ating handle A The anatomical movement of the arched extension keeps the patient s head in the sup port gt Pull the headrest out of the guide by pulling handle A Q vortice You can reduce the adjustment noise by pressing release A 59 06 313 D 3382 D 3382 201 01 13 02 31 8 Patient positions 8 3 MultiMotion headrest gt gt gt gt 1 32 Sirona Dental Systems GmbH Operating Instructions C4 Maxillary position Take the load off the headrest by lifting it slightly Press release A on the handle Let the headrest slide down slowly Let go of the release when the headrest reaches the desired position Rotation and tilt The MultiMotion enables rotation of the patient s head about the longitudinal axis of his body as well as lateral tilting of his head The MultiMotion is set to the desired position as follows Press and hold one or both of the two side control elements B The rotation and tilt adjustment locks of the headrest are now released Set the headrest to the desired position Let go of the control elements B The supporting surface is fixed in place Make sure that the headrest is indeed fixed in place after you let go of the contro
43. ccccseseecceeeeeeeeceeeeeeceueeeeecaaeeeeesaaaeeeseaaeeeesaeseees 68 13 2 Adjusting the water amount for the CUSPICOT ccccccccseeceeceesseeecaeseeeesceeeeeesaeeesesaaeeeesnauseesssaess 68 ToS Amalgam To ee a a a a a a ance eaeeee 69 13 4 Disinfection system optional cccccccccccsseeececeeceecesesececseeueeeecseeeeesseeeeeeeeueeeecsaaueesesaeeeeeesneessanaes 70 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH Table of Contents SIVISION Z sorae a Aaa 71 14 1 System ov rview of SIVISION Geisen ienne iadaan ia i aiaa ei oaan aii deti 71 T42 Camera Verns ae e aie eas eaten eee eae aa 73 14 3 SIROCAM 3 intraoral camera extra CQUIDMEMNT ccccseececcceseeeeeeseeeeeeceeseeeeceaaeeeeseueeeeesaaneeeseaanes 74 14 4 SIROCAM C intraoral camera extra equipment cccccccseseeeeeeeeeeeesaeeeeecauseeeeesaaeeeessuanseeessaases 76 14 5 Operating MOdeS oro VISION Ss ccna te ea et Jets oat a a euetvane ates 77 14 6 SIROCAM 3 SIROCAM C integrated in the dentist element video cseccecesseeeeeceesseeeaeeeeees 79 14 7 SIROCAM 3 SIROCAM C integrated in the dentist element PC ccccsssseeesseeeeeeeseseeeesaeeeeees 85 14 8 SIROCAM 3 SIROCAM C integrated in the assistant element ViIdGO cccssseeeeeeeeeeeeeeaeeeeees 89 14 9 SIROCAM 3 SIROCAM C integrated in the assistant element PC ccccccsseeeeeeeeeseeeessaeeeees 94 14 10 Switching between VIDEO mod
44. d Cleaning by the Practice Team A DANGER The suction hose handpieces contain magnets In the case of body contact of the suction hose hand piece in the vicinity of a cardiac pacemaker this can have a disturbing effect on the functioning of the car diac pacemaker Therefore avoid bringing the suction hose hand piece into the vicinity of a cardiac pacemaker Furthermore direct contact of the suction hose handpiece with magnetic cards can lead to data loss Suction hose handpieces with integrated magnets are marked with the following symbol WY 59 06 313 D 3382 D 3382 201 01 13 02 65 12 Assistant element 12 2 Suction handpieces on the assistant element Sirona Dental Systems GmbH Operating Instructions C4 Suction handpieces on the assistant element A SUCTION WITH CFS YES NO 66 The vacuum system switches on when you pick up a suction hose from the holder A CAUTION Observe the warning and safety information on page 9 vacuum system You can angle the suction handpiece by turning it A CAUTION With a wet suction system never pour water into the cus pidor while the unit is switched off A CAUTION If the vacuum system switches off by accident immedi ately remove the suction cannula from the patient s mouth lf the unit has no second saliva ejector hose for the sur gical cannula the thick suction hose must be used for surgical aspiration To insert a surgical can
45. d with original spare parts upon failure When having such work done we suggest that you request a certificate stating the type and extent of work performed including statements concerning any modifi cations of the rated parameters or of the operating ranges if applicable as well as the date name of orga nization and signature Modifications of this system which could impair the safety of the system owner patients or other persons are prohibited by law For reasons of product safety only original Sirona accessories approved for this product or accessories from third parties approved by Sirona may be used The user is responsible for dangers resulting from the use of non approved accessories If any equipment not approved by Sirona is connected it must comply with the applicable standards IEC 60950 for information technology equipment e g PCs and IEC 60601 1 for medical electrical equipment Any person who assembles or modifies a medical elec trical system complying with the standard IEC 60601 1 1 safety requirements for medical electrical equipment by combining it with other equipment e g by connect ing it with a PC is responsible for ensuring that the requirements of this regulation are met to their full extent for the safety of the patients operators and environment In case of doubt contact the manufacturer of the system components 1 Warning and safety information Electromagnetic compatibility EM
46. deo TOGGLING BETWEEN STILL IMAGE AND LIVE IMAGE Foot switch C or C With camera picked up and cursor being in the instru ments key block With the C foot switch Step on the foot pedal With the C foot switch Actuate the foot switch in direction A cursor upward Toggling between a STILL IMAGE and a LIVE IMAGE SWITCHING TO THE NEXT IMAGE Spray ON OFF key on the control panel Manually or by cursor using the foot switch with instru ments in place or camera picked up With C foot switch also left foot switch button only with camera picked up O worice If the camera is in the LIVE IMAGE mode the LIVE IM AGE is stored in the current memory location when you switch to the next image With the camera in place a BLACK SCREEN is stored in the current memory location when you switch to the next image with empty memory In SINGLE IMAGE mode switching to the next memory location e ifa STILL IMAGE is stored there it will be displayed e f no STILL IMAGE is stored there a LIVE IMAGE will appear with the camera picked up In QUAD IMAGE mode switching to memory location I Il II or IIl for image selection M The number of the currently selected image lights up in the upper right corner of the image 59 06 313 D 3382 D 3382 201 01 13 02 81 14 SIVISION 3 14 6 SIROCAM 3 SIROCAM C integrated in the dentist element video 82 Sirona Dental Systems GmbH Operating Instructions C4 TOGG
47. e and PC MOde ccccccceeceeeeeeeeee eee eeeeeeeeeeeaaaaeeeeeeaaaaaeeeeeesanaaeees 96 14 11 SIVISION3 second monitor function without SIROCAM3 SIROCAM C ccccceceeeecseseeeeeeneeeees 98 CEREC Chairline Option siseiccssvswcicstccasivaccinesovetwedeivenstieceszeuelectvesssaesarwicendicadeciavedncdes 99 tA GERE C ors Un ge eerie ater eee toe recent a eee meme Ste SY eee er Ova eaten ete ora 99 Extra equipment and accessories ccsccescceseeesecesecesseenseesseeseeeseeasecaeecnseoaseoaseneesones 100 16 1 Media block on the patient chair ccccccccecccsseccesececeecesseesessesesseseeseeeeessueeeneeeessueeessaeessseesensags 100 16 2 Hygienic headrest protection for motorized NEACrest cccsseececeseeeeeceeeeeeeceeeeeeeeeeeeeeeeseaeeeeesaeees 101 16 9 Cal CUSHION G opaa ais acest aes O ees dh dee eae a E T 101 IOA OCU VCH AU VIN Ue actrees reseed rete ge eats atte tec suse relent otc enae ane ne aed eet eaeenoee pean tene bamere a eseetssatles 102 16 5 Hydrocolloid coolant SUDDIY essi e a a acs a ae eee 102 16 6 Tray extra eguipment pore a a e Tar te Ee A e aa 103 16 7 X ray image viewer on the dentist CIOMENL ccceecccseecceceseeeceeeceseeeeseeeeesaeeeeseeseeteeeeenseesenseeenes 104 16 8 X ray image viewer on the lamp support tube cee ceeece ce eeeeceeeeeeeeeeeeeeeeeseeeeeseaeeesaeeesaeeesaeeensaes 104 16 9 X ray image Viewer on the Tay e irrenecdcireen aa a aaa E aia aeaa Eee
48. e of the PC can be used in this mode If the camera is the active instrument VIDEOCAM and the operating mode PC MODE appear on the dis play VIDEOCAM PC MODE Picking up the camera e The LIVE IMAGE window opens TOGGLING BETWEEN STILL IMAGE AND LIVE IMAGE Foot switch C or C With camera picked up and cursor being in the instru ments key block With the Ct foot switch Step on the foot pedal With the C foot switch Actuate the foot switch in direction A cursor upward Toggling between a STILL IMAGE and a LIVE IMAGE 59 06 313 D 3382 D 3382 201 01 13 02 85 14 SIVISION 3 Sirona Dental Systems GmbH 14 7 SIROCAM 3 SIROCAM C integrated in the dentist element PC Operating Instructions C4 USING THE FUNCTION KEYS Other functions e g the SIDEXIS VIDEXIS functions Tile Next Image Full Frame Zoom In Zoom Out Rotate Image as well as other PC controls can be assigned as desired to the following function keys on the dentist element control panel e Spray e Chip blower rpm x 1000 e Electric motor CCW rotation e Instrument light e Quick setting keys 50 and 1 e Cursor forward if the cursor is between the spray and chip blower keys with C foot switch only if the camera is in its holder e Cursor forward if the cursor is between the S and 0 chair program keys e With C foot switch cursor forward With C foot switch Actuate foot switch in direction A cursor upw
49. e the foot switch in direction A after picking up the V 0 2 instrument rpm x 1000 With cursor control disabled Mode dialog 11 8 Actuate foot switch in direction A With instrument picked up Activation of the instru ment Actuate foot switch in direction B With instrument picked up No function Swing foot switch to the left C With instrument picked up Spray ON OFF for burr instruments or SIVISION function With instruments in place SIVISION function Swing foot switch to the right D With instrument picked up Chip blower ON for burr instruments or SIVISION function With instruments in place SIVISION function 59 06 313 D 3382 D 3382 201 01 13 02 25 6 Foot switch Sirona Dental Systems GmbH 6 3 Selecting the chair program Operating Instructions C4 Automatic cursor control with C foot switch A yellow diode on the dentist element indicates the posi tion of the cursor The cursor path is marked by lines 1 After you switch on the system or when the chair has reached the entry exit position 0 the cursor is 40 a between the chair program keys 1 and 2 2 When you pick up an instrument or activate any of 20 i the instruments the cursor jumps to a position be tween the spray and chip blower keys in the first in 0 2 strument block rpm x 1000 i i If the cursor is in the quick setting key column at the very left it also jumps to a position between the spray and chip
50. eeeeeceeeeeeeeseeeeeecseaeeeeesaaeeeeesanseeesaaees 52 TOA YGUSBIGOR TUES IMIG ensa fe cst 5 yak ies te i i taken Pact eke De ISS hea at aa eeu a ane 53 10 5 Purge Auto Purge function purging the water Paths ccccccccssseeeeeeeeeeeeeceeeeeeseseeeeeesesseeesaaees 54 Basic treatment center settings in the Mode dialog scccessceeeseeeeeeeeseeeneeeeeeeneeees 57 Wel IVIOGE KO ros o a tiie sa clsadaatiolan eben tien ace E E 57 11 2 Mode NACL PUMP OFF or ON for instrument holder cccccseeeeecesseeeeeeeeeeeeseuseeeeanaeeeeesseseees 57 tes Mode MAINIENANC E zener E t 58 11 4 Mode SERVICE ONLY START STOP wecccsccccsesascsnceesaceccevaalesceceuatcnssasaentceyengsaneonaanesigaaaicaauasanieciends 58 11 5 Mode FC CONTROL MODE ON OFF VARIABLE cccecceccceseeeeeeeeeeeeeseeeseeeeeeaaeeeeeaeneeeesaaees 58 tG Mode UMES OURS MIN aa E a oes eens 58 Iz Mode DAY MON YEAR eridi n i a a a Guth over E 59 11 8 Mode FOOT CONTROL NORMAL EXTENDED ccccccccccseeeeeceeeeeeeeceesseecsenaeeeeeenasseeesseaes 59 11 9 Mode BOWLCFLUSHONS YES NO crsa R RE a adaa 59 110 Mode CUP FILEON S YES NO wis eee dete 59 11 11 Mode WHITE BALANCE only with an integrated SIROCAM 3 ccscceceseeeeeeeeseeeeeseeeeeeessaeeees 60 11 12 Instrument settings via Mode dialog REMOVE INSTRUMENT ccccccsseeeeecseeeeeeeeeeeeeeeeeeees 61 11 138 Mode FUNCTION TOGGLE MOMENTARY cc
51. en when it is placed in its holder as one of the states black screen white screen or quad image is always active The slide switch 3 is used for presetting the depth of focus The camera button 4 is intended for controlling differ ent SIVISION 3 functions Q worTice For camera operation and further information please re fer to the operating instructions of the SIROCAM 3 norice The camera handpiece contains data making it possible to restore the factory set color definitions regardless of the dental treatment center where the camera is used Thus the camera can be used at different dental treat ment centers To customize the color settings you can perform a white balance as long as the camera is active see Mode dialog section 11 11 59 06 313 D 3382 74 D 3382 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions C4 59 06 313 D 3382 D 3382 201 01 13 02 14 SIVISION3 14 3 SIROCAM 3 intraoral camera extra equipment Hygienic protective covers for SIROCAM 3 Hygienic protective covers are available for the camera They can be ordered under REF 59 38 654 Package size 500 pcs How to use the hygienic protective covers 1 Hold the hygienic protective cover with its paper side face down and insert the camera with the optical system downward into the cover 2 Pull off the upper protective foil with the blue stripe 3 Then pull off the backing paper 4 Final
52. end of the hose 3 with the cannula through the stopper and into the NaCl bottle as illus trated e The regulator in the hose clip 4 must be in the top most position completely open e Run the long hose 5 along the corresponding mo tor hose up to the contra angle handpiece and fas ten it with the clips 6 e Fit the coupling 7 onto the hose and connect it with the thin silicone hose 8 e Connect the spray clip 9 with the thin hose and at tach it to the contra angle handpiece notice The one way NaCl pump must be secured with a cap af ter it is attached to the drive 10 Only then is proper op eration of the pump guaranteed The safety cap is sup plied with every one way pump Pump hose set The peristaltic pump hose set 2 is a disposable arti cle and can be purchased in packs of 10 pcs as con sumable material under article number F 58707 directly from the manufacturer Ordering address Satelec Industriestr 9 D 40822 Mettmann Germany notice How to preset a certain instrument holder for saline solu tion is described under Basic treatment center settings in the Mode dialog 11 2 on page 57 A CAUTION The pump flow rate must be at least 7Oml min for rea sons of safe cooling and to prevent a pressure rise in the hose risk of bursting This is not always given when us ing third party ultrasonic tips Switching the NaCl pump on off After picking up the respective
53. entilation slots on the unit be covered since otherwise the air circulation will be obstructed Do not spray with disinfectants or the like into ventilation slots The suction removal of aluminum and other metal oxides from blasting devices via the automatic separator and the amalgam separator integrated in the treatment cen ter is prohibited This would cause extreme wear and clogging of the suc tion and water paths A separate vacuum system must be used in connection with metal oxide blasting devices Treatment centers equipped with a central wet suction system are generally suitable for suction removal of the above material However make sure to observe the instructions provided by the manufacturer of your vac uum system No restrictions apply when using salt blasting devices in connection with Sirona treatment centers However in such cases make sure that the system is subsequently flushed with an adequate amount of water Please observe the maximum load capacity of the chair of 135kg according to EN ISO 6875 tested with a four fold safety factor according to IEC 60601 1 Intermittent operation 1 min ON 7 min OFF witha motor current of 1 5A 6 duty time cycle time 250s Despite the outstanding quality of your treatment center and regular care by the practice team it is required in the interest of operational safety that preventive mainte nance be performed at predetermined intervals In order to guar
54. er minute appears on the display You can set the speed with the quick setting keys on the left side of the dentist element control panel lf the cursor is in the intensity setting block you can set the speed also with the foot switch using the forward backward cursor When you press the corresponding key briefly lt 0 5s then the value in RPM indicated next to the relevant key appears on the display Key 1 200 rpm Key 50 20000 rpm Key 100 40000 rpm When you set the speed with the cursor the displayed value is incremented decremented in steps of 10000 when you actuate the foot switch briefly lt 1s forward or backward At the values of 200 20000 and 40000 the green LED in the corresponding key lights up When you press and hold down a key for gt 0 5s you adjust the speed in predefined increments Increments 200 fro 200 2000 rpm of m Increments 400 fro 2000 10000 rpm of m Increments 1000 fro 10000 40000 rpm of m When you press a key whose value is gt the value shown on the display for gt 0 5s the speed is increased When you press a key whose value is less than the value shown on the display for gt 0 5s the speed is reduced When you actuate the foot switch forward or backward for gt 0 5s the displayed speed value is increased or reduced in predefined increments When you set intermediate values the green key LED does not light up Counterclockwise rotation k
55. ey Counterclockwise rotation key only for electric motor When this key is activated the green LED in the key is illuminated 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 9 Dentist element and instrument functions Operating Instructions C4 9 4 Highspeed handpiece After you start the electric motor with the foot switch an audible warning signal sounds 6 times You can activate counterclockwise rotation of the elec tric motor also with the foot switch e 4 way foot control plate to the left counterclockwise rotation e 4 way foot control plate to the right clockwise rota tion The corresponding motor must have been picked up before Highspeed handpiece Starting the highspeed handpiece When you pick up the highspeed handpiece O bar or PSI according to the presetting in Mode dialog 10 13 appears on the display When you start or operate the highspeed handpiece the current air pressure in bar or PSI always appears on the display PSI 9 5 SIROSONIC L scaler Tip protector The tip protector is used as a tool for screwing in instru ment tips A CAUTION While the handpiece is in its holder the tip protector must remain fitted to prevent injuries Intensity setting setting When you pick up the SIROSONIC L handpiece the programmed intensity value appears on the display 59 06 313 D 3382 D 3382 201 01 13 02 41 9 Dentist element and instrument functions 9
56. f the product and or warns against possible operating errors This warning symbol warns against possible hazards for A WARNING the product or the user In case you get stuck despite having thoroughly studied the Operating Instructions please contact your dental depot Your C4t Team 59 06 313 D 3382 2 D 3382 201 01 13 02 Sirona Dental Systems GmbH Table of Contents E Table of Contents a Warning and Safety information cccceeeeeeeeeeeeeeeeneeee eee eeeeneeeasseaseeeaeeneaeeneseanasenenens 7 Technical descriptor ssis Eaa ASEA 11 SV SLC IM VON SONS arasia a E O 12 3 1 System overview C4 cacccincadsinaanasaccsnnaiannndanndsonnnsanttiansannesninadeinnadennadamniexinaatcndensnimdaturnalbiecnsiadtzuncaran 12 3 2 System ov rvi w C4 Caflrescioiinicsniioirionmd onire nnee naera aN eaaa aoi iii dan i E 13 3 3 System overview C4 CaDINGE riscceicssccinssssivosvoesavedsavesvadecessveusadsereravodaberndauenindabiersstaseosuseennevedwuaweewaes 14 Controls and functional elements cceeeeeeesseeeesseeeeneeeeeseeeeneeeeeseeeeseeeoeneeeeneesonanes 15 4 1 Control panel on the dentist ClEMENL cccccceeccceeeecceeeeeeeeeeeeesaeeesseeseeeeeeeseeseeseeseesaeseesegeeessaeeeees 15 4 2 Control panel on the assistant element cccecccccsseeeeeeeeseeeecaueeeeeeeaeeeeeeeeaseeeeseueeeesaeeeeesnaneeeeesaees 19 Putting the system into operation ssssnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn mnn
57. g message is dis played MAINTENANCE REQUIRED The display message then disappears as soon as an instrument is removed from its holder Q notice This message can be reset only by the service techni cian after completion of maintenance work A CAUTION The dental chair has a maximum load capacity of 135kg according to EN ISO 6875 tested with a four fold safety factor according to IEC 60601 1 The patient s arms and legs must rest on the upholstery of the chair Preselecting the user The treatment center offers the possibility of managing two different chair and instrument programs for two users Preselect user A or B using the A B key with all instru ments in place The preselected user is shown in the top left corner of the display All settings which have been stored for that user are then activated 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 6 Footswitch Operating Instructions C4 6 1 C foot switch Foot switch Ct foot switch This foot switch enables hands free operation by means of the cursor control but also manual operation by means of the keys The foot switch has a 4 way foot control plate for cursor navigation which works independently of the pedal Functions Step on foot pedal instrument picked up Activation of the instrument lf appropriate intensity control relative to pedal movement if speed controller foot switch has been preset under Mode 1
58. hat no tap water enters the filler trough For reorders DENTOSEPT P 1 carton 6 x 1 liter REF 33 18 156 For Canada and Japan only 1 carton 6 x 1 liter REF 59 69 535 Microbiological water test after an operating pause of more than 1 week Sanitation of the unit Perform sanitation every 4 weeks This is the only way to effectively combat the formation of biofilm in the water paths see instructions Care and Cleaning by the Practice Team 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 14 SIVISION3 Operating Instructions C4 14 1 System overview of SIVISION 3 SIVISION 3 System overview of SIVISION 3 SIVISION on the lamp support tube _ e Rotatable E e swivelable Monitor on tray arm e Rotatable e swivelable Monitor on swivel arm e Rotatable e swivelable e Height adjustable 59 06 313 D 3382 D 3382 201 01 13 02 71 14 SIVISION 3 14 1 System overview of SIVISION 3 72 0O O OO Sirona Dental Systems GmbH Operating Instructions C4 A CAUTION Make sure that the patient does not collide with the mo nitor during movements of the dental treatment chair and or operation of the cuspidor Swivel the monitor out of the collision area if necessary SIVISION 3 monitor versions e 15 Monitor e with glass pane e 19 Monitor e with glass pane e with loudspeaker A CAUTION The loudspeaker socket of the monitor may be connec ted only to a device w
59. hich complies with IEC 60950 e g PC or IEC 60601 1 and under no circumstances e g to a stereo system etc 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 14 SIVISION3 Operating Instructions C4 14 2 Camera versions Camera versions SIROCAM 3 e Integrated 4 view image memory e 3 fold adjustable focusing range e Titanium case SIROCAM C e Integrated 4 view image memory e 2 fold adjustable focusing range e Plastic case 59 06 313 D 3382 D 3382 201 01 13 02 73 14 SIVISION 3 Sirona Dental Systems GmbH 14 3 SIROCAM 3 intraoral camera extra equipment Operating Instructions C4 SIROCAM 3 intraoral camera extra equipment The SIROCAM 3 intraoral camera combined with SIVI SION 3 is a perfect system for effective communication with the patient The camera images cannot be used for diagnosis The SIROCAM 3 intraoral camera is a sensitive optical instrument and must therefore always be handled with care The camera illuminates the tooth areas to be imaged with 7 white light LEDs 1 These are arranged around the entrance prism 2 The LEDs and the lens are protected by a scratch proof antiglare glass cover A CAUTION Intermittent camera operation t1 1 min on t2 3 min off The camera heats up during operation To prevent overheating of the camera the camera must be put down for a time interval t2 3 min after an operat ing time of t1 1 min The camera will heat up ev
60. iately A DANGER After changing hoses press the water button of the SPRAYVIT repeatedly until water comes out Only then can you begin treatment Hi 1 2 Satelec Mini L E D curing light on the assistant element For safety instructions and operation see page 46 59 06 313 D 3382 D 3382 201 01 13 02 67 13 Water unit Sirona Dental Systems GmbH 13 1 Swivelable cuspidor alternative equipment Operating Instructions C4 Water unit Swivelable cuspidor alternative equipment The cuspidor on the water unit can be swiveled manually by approx 110mm towards the patient chair Collision protection Certain chair movements are locked as long as the cus pidor is swiveled in When you start a programmed movement S 0 1 or 2 the cuspidor first moves back to its starting position before the chair moves to the pro grammed position When you press a key for the individual adjustment of the chair i e height adjustment up down or backrest tilt backward forward the cuspidor also swivels back first and if the corresponding key is still pressed the chair moves You can make individual adjustments of the motorized headrest even when the cuspidor is swiveled in If the cuspidor is swiveled in while the chair is moving the program is aborted This is signaled by a double beep Adjusting the water amount for the cuspidor e Open the flap 1 on the base of the water unit e Adjust the amount of water with
61. ing you can interrupt or restart the suc SUCTION WITH CFS tion flow of the large suction hose not at the saliva ejec YES NO tor hose by pushing the 4 way foot control on the chair in any direction When you put the large suction hose in its holder while the suction flow is interrupted the suc tion flow is automatically restarted when you pick up the hose again 59 06 313 D 3382 D 3382 201 01 13 02 63 11 Basic treatment center settings in the Mode dialog Sirona Dental Systems GmbH 11 19 Mode WHITESCREEN YES NO Operating Instructions C4 Mode WHITESCREEN YES NO Presetting a white screen for the SIVISION A monitor If YES flashes WHITESCREEN The X ray image viewer key switches ON OFF both YES NO the X ray image viewer and a WHITE SCREEN on the SIVISION 3 monitor If NO flashes The X ray image viewer key only switches the X ray image viewer ON and OFF If an X ray image viewer and SIVISION 3 are installed always select NO 11 20 Mode A B VIDEO MODE ON OFF Locking the video mode switchover d Mode _ gt This mode is only displayed in connection with an inte grated SIVISION 3 A B VIDEO MODE If ON is flashing ON OFF You can use the A B key to switch between VIDEO mode and PC mode after picking up the SIVISION 3 camera If OFF is flashing You cannot use the A B key to switch between VIDEO mode and PC mode for SIVISION 3 This p
62. ipment Additional equipment which is approved for dental use e g by EMS may be connected to a media block on the base of the chair observe manufacturers specifications for the additional equipment The media block is equipped with quick couplings for air and water and an outlet with a separate fuse 6 3A for non heating equipment For treatment centers with a disinfection system the Line voltage DVGW approval EN 1717 DIN 1988 remains valid also with an integrated media block In this case the addi tional equipment connected to the treatment center also complies with the requirements of EN1717 DIN1988 Technical data and requirements e Connected equipment is treated with disinfected wa ter if a disinfection system is installed During regular operation this is 0 1 to 0 2 hydrogen peroxide during sanitation 1 4 A CAUTION Before connecting any additional equipment check to make sure that it is suitable for hydrogen peroxide If the connected equipment is not suitable for the higher sanitation concentration Sirona recommends to discon nect it from the treatment center during sanitation and to perform a separate sanitation in accordance with the manufacturer s specifications Sirona does not assume any liability for possible dam age to the connected equipment Specification of pressure and flow conditions Pressure Flow Water 2 2 0 2 bar max 300 ml min Air 4 4 0 5 bar max 70 NI min
63. l elements 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions C4 59 06 313 D 3382 D 3382 201 01 13 02 8 Patient positions 8 3 MultiMotion headrest Removing the MultiMotion For certain treatments e g of children it may be expe dient to remove the MultiMotion completely in order to obtain better access to the patient The patient s head will then be supported on the contact surface of the headrest extension F To remove the MultiMotion proceed as follows 1 Press release button C 2 Pull the complete headrest out of the headrest ex tension 3 Cover the opening of the headrest extension with cover cap E 4 Ifa children s head pad D is available place it on the headrest extension The head pad is held mag netically notice The children s head pad D is not included in the scope of supply however is available from your dental dealer A DANGER The children s head pad D contains a strong mag net on its bottom side This magnet could affect any cardiac pacemaker located nearby Therefore do not allow patients users and technical personnel with a cardiac pacemaker to be located near this magnet Furthermore direct contact of the head pad with magnetic cards can lead to data loss Q vortice Deposit the removed MultiMotion in a safe place where it cannot fall onto the floor Inserting the MultiMotion To insert the MultiMotion proceed as follows
64. l sounds If the white balance has not been successful USER will not be displayed in bold type You may repeat the white balance as often as desired Different color patterns will produce different results with respect to the color settings For example a color area with a high amount of blue will reduce the amount of blue color in the video image 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions C4 11 Basic treatment center settings in the Mode dialog 11 12 Instrument settings via Mode dialog REMOVE INSTRUMENT If you want to reset the camera to its factory settings select HOME with the keys When you confirm by pressing the Mode key HOME is displayed in bold type To exit this Mode dialog select EXIT and press the Mode key or put the camera back in place Automatic exit from the dialog is disabled as soon as USER or HOME is selected This allows you to repeat the white balance as often as necessary until you obtain the desired result Instrument settings via Mode dialog REMOVE INSTRUMENT A TAKE INSTRUMENT A MAX LIGHT VOLT 3 9 V WARNING 59 06 313 D 3382 D 3382 201 01 13 02 This Mode dialog enables the following settings e Instrument light voltage and e Maximum torque of SL motors Setting the instrument light voltage You can change the voltage setting for instruments in this Mode dialog First a message prompting removal of an instrument appea
65. le is cleared except for the swivelable cuspi dor and assistant element With instruments in place the last activated safety switch is indicated in plain text on the display e TILTING PART for motorized headrest e BACKREST BACKREST e TOEBOARD mee e ASSISTANT ELEMENT is also displayed when the cuspidor safety switch is activated The message CUSPIDOR appears after 10 seconds if the automatic return movement of the cuspidor to its position is inhibited 59 06 313 D 3382 D 3382 201 01 13 02 27 7 Program selection 7 2 Program selection 7 2 Program selection 28 Sirona Dental Systems GmbH Operating Instructions C4 Keys for selecting the programmed patient positions With swivelable cuspidor Before the chair moves to the selected program position the swiveled in cuspidor automatically returns to its starting position Factory settings The operation light switches OFF automatically before the chair moves to the entry exit position 0 or the mouth rinsing position S The operation light switches ON automatically after the chair has reached patient position 1 or 2 Changing the factory settings When programming the patient positions you can preset whether the operation light should switch OFF or ON in the different chair programs 0 S 1 or 2 see page 36 Program key 0 Intended for the entry exit position Program key S with memory function In the S program you can program
66. lt You can tilt the backrest with the lower 4 way switch at the back of the headrest e Lever to the left The backrest tilts backward e Lever to the right The backrest tilts forward Height adjustment You can adjust the height with the lower 4 way switch at the back of the headrest e Lever down The chair moves down e Lever up The chair moves up 59 06 313 D 3382 D 3382 201 01 13 02 35 8 Patient positions 8 6 Programming patient positions 8 6 Programming patient positions 36 Sirona Dental Systems GmbH Operating Instructions C4 The four factory set programs can be reprogrammed in dividually by user A and user B h Programs 1 and 2 Entry exit program 0 Mouth rinsing program S Move the chair to the desired treatment position by pressing the different setting keys see page 30 To make the SIROLUX FANTASTIC operation light switch on or remain off when the chair reaches the programmed treatment position you must switch the lamp ON or OFF now This setting is then also pro grammed A CAUTION In order to avoid damage to the dentist and assistant el ements and to the chair upholstery make sure that these elements do not protrude into the movement range of the chair 3 To save the program settings press the desired pro gram key approx 3 seconds until an audible signal sounds and the LED of the corresponding key lights up Programming is completed now O notice Pr
67. ly stretch the hygienic protective cover over the camera from front to rear A CAUTION For optimum image quality there must not be any folds in the transparent area of the cover above the lens window A CAUTION Use only the hygienic protective covers offered by Siro na Prior to each application on a new patient the camera must be covered with a new hygienic protective cover 75 14 SIVISION 3 Sirona Dental Systems GmbH 14 4 SIROCAM C intraoral camera extra equipment Operating Instructions C4 SIROCAM C intraoral camera extra equipment The SIROCAM C intraoral camera combined with SIVI SION 3 is a perfect system for effective communication with the patient The camera images cannot be used for diagnosis The SIROCAM C intraoral camera is a sensitive optical instrument and must therefore always be handled with care The camera illuminates the tooth areas to be imaged with 6 white light LEDs 1 These are arranged around the single lens optical sys tem 2 The LEDs and the lens are protected by a scratch proof antiglare glass cover A CAUTION Intermittent camera operation t1 1 min on t2 3 min off The camera heats up during operation To prevent overheating of the camera the camera must be put down for a time interval t2 3 min after an operat ing time of t1 1 min When the camera is in LIVE IMAGE mode it is possible to toggle between close range and far range by pressing button
68. mbH Operating Instructions C4 To start the polymerization cycle briefly press the ON OFF switch 6 This is confirmed by an audible signal In each mode an audible signal sounds every 5 sec onds The end of the cycle is also indicated by an audible sig nal You may interrupt the cycle at any time though by lightly pressing the ON OFF switch Technical data General technical data Model Mini L E D Weight of handpiece without 105g hose Dimensions dia 23mm x 240mm Power supply of handpiece 5VDC 2A Thermal safety Overheat protection Optical specification Wavelength 420nm 480nm Intensity dia 7 5mm standard version 1100 MW cm Intensity dia 5 5 mm optional available from Satelec 2000 MW cm Power 450 mW 500 mW Laser power lt ImW 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 10 Operation light tumbler filling cuspidor flushing purge Operating Instructions C4 10 1 Operation light Operation light tumbler filling cuspidor flushing purge Operation light Operation light dentist element control panel Press the SIROLUX key briefly to switch the operation light ON or OFF When you press this key for more than 3 seconds the OPERATING LIGHT Here you can set a light intensity between 20 and A 100 with the keys approx 8000 lux approx 24000 lu
69. n 21 FOOU SV NG creisis eE 23 6 1 CEOS NE eee R E queeeaeuisicasuiscsiee nace onceeeasaceessors 23 oe OTO EWO aa le eran eee neo ee ee eee tee ee eee eee ene eee oe 25 6 3 Selecting the Chair ProQram ccccccccccssseccceeeccceeececeeeccceeeeeseeceeseeeeseuceeseeeeesuseesauseesauseeseneeesaeeeeess 26 Program Selecon E E EE 27 7 1 OY PREN EEN EEEE EE E cee E E E E E A A E T E EE TE 27 7 2 PO AN SCICCUON eee E E E E E T E E E A 28 To MOVEMENT STOP eia E a sete a EEAS 29 Patent OS UL ONS sinss tseie recnreteseaseenocene te nataneet asncsaeatincetiseanaactisteeedenaeeneuuenecn 30 8 1 Flat IC AGI SST sissies dele satemtanbsteaceeadatendceendeenddonedusdieaesvedeehedbenanee paaeasatectndnacdechedienccemeace bases E 30 8 2 Articulated NEACIeESt cccccsscccsseeceeeeceeeeceeecueceeeeceaeeceueecaeeceueecsueecsuceseueesaeessusesseeeseeseesseesseeessaees 30 8 3 NVIUITIVIQUION Headrest i aseceb sca ciccdcsate aaa ERA EEE 31 8 4 Adjusting the patient positions MANUALY cceecceceeeceeeeeeeeeeeeeeeeeeeeeeeeeseeeeeseeeeesaeeeesaeeeesseeeeseeeenes 34 8 5 Motonzed Headie Stasina iaaa a nes ica tiosanas totems a Ee aaan are eet EG 35 8 6 Programming patient positions ccccceccceececeeecceeeeceeeceeeeceeeceeeseceueeseueeseuessaeessaeesseeeseeeeseeeeseesseeeess 36 Dentist element and instrument functions sssssssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn na 37 9 1 PE AS CUI sossiid raina A EE E AEEA 37 9 2 General instrumen
70. n the SIV ISION monitor ON OFF if YES flashes notice WHITESCREEN WHITESCREEN NO should be selected if an X ray im YES NO age viewer is installed If no X ray image viewer is in stalled select WHITESCREEN YES BLACK SCREEN 100 quick setting key on the control panel Manually or by cursor using the foot switch with instru ments in place or camera picked up Cursor forward if the cursor LED next to the quick setting keys lights up e Toggling between any view and a BLACK SCREEN e The previous view reappears when you press this key again worice WHITE SCREEN BLACK SCREEN is only possible when AUTO is set on the monitor see SIVISION 3 Op erating Instructions for the Flat Screen Monitor 59 06 313 D 3382 88 D 3382 201 01 13 02 Sirona Dental Systems GmbH 14 SIVISION3 Operating Instructions C4 14 8 SIROCAM 3 SIROCAM C integrated in the assistant element video SIROCAM 3 SIROCAM C integrated in the assistant element video Operation in video mode If a PC is connected PC mode must be switched OFF See section 14 10 Switching between VIDEO mode and PC mode In this version the SIROCAM 3 SIROCAM C intraoral camera is installed in holder 1 or 2 of the assistant ele ment It is operated exclusively with a separate foot button in the chair base and the camera button Picking up the camera e Ifa STILL IMAGE or QUAD IMAGE was displayed while the camera
71. ncil Directive 93 42 EEC of June 14 1993 concerning medical devices 11 3 System versions Sirona Dental Systems GmbH 3 1 System overview C4t Operating Instructions C4 System versions System overview C4 1 43536 7 8 9 10 11 12 13 14 16 17 W Slee MS i N y JL 1 Assistant element 13 Holder 4 3rd electric motor highspeed handpiece 2 Holder 1 Mini L E D polylight or 3rd suction hose or Seat or SIROSONIC L scaler or Mini L E D SIROCAM 3 SIROCAM C polylig 14 Holder 5 4th burr drive only highspeed handpiece 3 Holder 2 SPRAYVIT in the assistant element or SIROCAM 3 SIROCAM C or SIROSONIC L or Mini L E D polylight or i SIROCAM 3 SIROCAM C Holder 3 Suction handpi eae ae i aad 15 Additional instrument holder only for SIROCAM 3 5 Holder 4 Saliva ejector SIROCAM C 6 Control panel on the assistant element 16 Control panel on the dentist element 7 Rigid or swivelable cuspidor 17 C4 dentist element 8 Tumbler filler 18 Locking brake on the assistant element 9 Water unit with amalgam rotor disinfection system 19 Unit main switch t ti tor wet sucti i a cc aac 20 Flat headrest or manually adjustable headrest or 10 Patient chair option folding armrest motorized headrest 11 Holder 1 SPRAYVIT in the dentist element 21 4 way foot control of chair 12 Holder 2 and 3 Electric motor highspeed hand 22 Unit foot switch C or C eor piece DUM CIES 23 Foot button for SIROCAM 3 SIROCAM Con the
72. nerated on the PC is displayed on the SIVISION monitor 59 06 313 D 3382 D 3382 201 01 13 02 T7 14 SIVISION 3 14 5 Operating modes of SIVISION 3 A VIDEOCAM PC MODE A VIDEOCAM VIDEO MODE A B VIDEO MODE ON OFF 78 Sirona Dental Systems GmbH Operating Instructions C4 SWITCHING TO PC MODE A B key on the control panel Only with e camera picked up and activated e manually or by cursor using the foot switch M VIDEOCAM and the operating mode PC MODE now appear on the display M The image from the PC monitor e g SIDEXIS VI DEXIS appears on the SIVISION monitor The cam era switches to LIVE IMAGE This mode remains active even after you switch OFF and back ON the treatment center SWITCHING TO VIDEO MODE A B key on the control panel Only with e camera picked up and activated e manually or by cursor using the foot switch M VIDEOCAM and the operating mode VIDEO MODE now appear on the display M The SIVISION monitor displays the camera image This mode remains active even after you switch OFF and back ON the treatment center This toggling function of the mode switchover key can be disabled in Mode dialog 11 20 Mode A B VIDEO MODE ON OFF to prevent inadvertent switching 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 14 SIVISION3 Operating Instructions C4 14 6 SIROCAM 3 SIROCAM C integrated in the dentist element vide
73. ng the cabinet away please take care that nothing is crushed and that no objects lying on the den tist element are knocked off A CAUTION When moving the chair via program or manually make sure that the patient or the patient chair does not under any circumstances come into contact with the support arm or the dentist element Spray You can switch the spray cooling ON OFF by pressing the spray key on the dentist element control panel If spray is preselected the green LED in the key is illumi nated With the C foot switch you can switch the spray for the picked up instrument ON OFF by stepping on the left foot switch button 3 With the C foot switch the cursor jumps directly between the spray and chip blower keys when you pick up an instrument You can switch the spray cooling ON OFF by swinging the foot switch to the left C 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 9 Dentist element and instrument functions Operating Instructions C4 9 2 General instrument functions Spray amount The spray amount is preset at the factory However it can be adjusted by means of the control valve at the bot tom front part of the dentist element To make the adjustment loosen the ring 5 counter clockwise adjust the spray by turning the screw 6 and screw the ring 5 tight again FEO ff pI This setting is then valid for all burr drives Chip blower C foot switch With a Ct foot
74. ngs dialog OPERATING LIGHT Tumbler filling Pressing this key for a while displays the settings dialog CUP FILL TIMER Cuspidor flushing Pressing this key for a while displays the settings dialog BOWL FLUSH TIMER Freely selectable function e g call key always functions as button freely available relay 230 V 6 A connected by the service engineer Freely selectable function The function can be preset in the Mode dialog as button or switch freely available relay 230V 6 A connected by the service engineer 17 4 Controls and functional elements 4 1 Control panel on the dentist element 18 Sirona Dental Systems GmbH Operating Instructions C4 Chair functions gray keys for manual chair settings Tilt backrest backward or forward Height adjustment down up E Additional functions of the control panel video keys Q vortice Apart from the previously described functions the keys of the dentist element have additional functions in con nection with the video application These are described in chapter 14 starting on page 71 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 4 Controls and functional elements Operating Instructions C4 4 2 Control panel on the assistant element 4 2 Control panel on the assistant element Control panel BD Gz Main functions dark blue keys Mouth rinsing position chair program with memory function freely prog
75. nts should not come in contact with water from the treatment center The use of sterile solutions is recommended Air and water supply must meet the requirements speci fied in the installation instructions Use only clean water To ensure compliance with the medical and national legal requirements for water from treatment centers Sirona recommends equipping the treatment center with a disinfection system As owner of the treatment center you are responsible for the water quality and may have to take alternative measures to ensure its compliance if you operate the treatment center without a disinfection system Please contact your specialized dealer or your relevant dental association for the respective national require ments and measures To avoid personal injury and material damage you must also observe the warning and safety information pro vided in the present operating instructions They are highlighted by the caption i NOTICE A CAUTION or A WARNING 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions C4 Symbols used Ventilation slots Vacuum system Patient chair Electric micromotors in dentist element Drive motors for chair and backrest Maintenance of the treatment center Dismantling and reassembly 59 06 313 D 3382 D 3382 201 01 13 02 1 Warning and safety information Observe accompanying documents on name plate of chair Under no circumstances may the v
76. nula please attach the adapter supplied If the unit is equipped with a second saliva ejector hose the surgical cannula can be inserted directly into the saliva ejector handpiece You can interrupt or restart the suction flow of the large suction hose also by pushing the 4 way foot control on the chair in any direction You can preset this under Mode 11 18 When you put the large suction hose in its holder while the suction flow is interrupted the suction flow is automatically restarted when you pick up the hose again 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 12 Assistant element Operating Instructions C4 12 3 SPRAYVIT on the assistant element A CAUTION Make sure to hold the suction cannula in such a way that the cannula opening cannot attach itself to the oral mu cous membranes by accident Q notice The factory set suction power can be adjusted in the wa ter unit by a service engineer 12 3 SPRAYVIT on the assistant element If the SPRAYVIT is the only instrument that has been picked up you may switch the instrument light on or off Its brightness is set to an optimum value and cannot be changed The instrument light switches on when you activate the SPRAYVIT if preset The instrument light switches off after a time lag of 10s when the SPRAYVIT is no longer activated When you place the SPRAYVIT back on the instrument rack the instrument light switches off immed
77. o SIROCAM 3 SIROCAM C integrated in the dentist element video Operation in video mode In this version the SIROCAM 3 SIROCAM C intraoral camera is installed in holder 5 of the dentist element or in an additional holder on the dentist element The camera can be controlled with the unit foot switch if no other instrument is activated picked up and control lable with foot switch when you pick up the camera M Ifthe camera is the active instrument VIDEOCAM and the operating mode VIDEO MODE appear on the display A VIDEOCAM VIDEO MODE 59 06 313 D 3382 D 3382 201 01 13 02 79 14 SIVISION 3 Sirona Dental Systems GmbH 14 6 SIROCAM 3 SIROCAM C integrated in the dentist element video Operating Instructions C4 SAVING AN IMAGE In VIDEO mode the camera can save 4 still images con secutively indexed with I H Ill and IMI A 5th view shows a QUAD IMAGE in which these 4 still images are tiled on the screen Picking up the camera If a STILL IMAGE or QUAD IMAGE was displayed while the camera was in place this view is retained If a BLACK SCREEN or a WHITE SCREEN was dis played while the camera was in place the view preced ing the BLACK or WHITE SCREEN i e a LIVE STILL or QUAD IMAGE reappears 59 06 313 D 3382 80 D 3382 201 01 13 02 Sirona Dental Systems GmbH 14 SIVISION3 Operating Instructions C4 14 6 SIROCAM 3 SIROCAM C integrated in the dentist element vi
78. offers possibility of automated purging of all water carrying instruments in the dentist element of the assistant Sprayvit and of the tumbler fill ing unit All of the instruments inserted in the sanitation bowl will be purged when APURGE is activated If the instru ments remain in the sanitation bowl after the treatment center is switched off the purging process will automat ically be started again the next time the treatment center is switched on We recommend the APURGE function in the following cases e APURGE function before beginning and at the end of the work day A complete purge cycle is performed following acti vation The instruments remain in the sanitation bowl and the treatment center can be switched off On the next day the APURGE function is automati cally performed again on all of the instruments re maining in the sanitation bowl as well as on the tum bler filling unit immediately after the treatment center is switched on Then you can prepare the treatment center for daily practice operation e APURGE function after longer periods of disuse A complete purge cycle is performed following acti vation The instruments remain in the sanitation bowl and the treatment center can be switched off Now you can switch on the treatment center briefly every day and then switch it off again after the purg ing process Setting the APURGE function Activate the selection dialog box by pressing
79. ogramming is not possible by activating the program keys with the foot switch cursor control Thus program ming errors are avoided 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 9 Dentist element and instrument functions Operating Instructions C4 9 1 Dentist element Dentist element and instrument functions Dentist element Maximum load capacity The maximum load of the dentist element is 2kg 4 4 Ibs Dentist element C4 Cart The maximum load of the dentist element C4 Cartis 2kg 4 4 Ibs A CAUTION Risk of toppling over Move cart slowly and only on even floors without any obstacles A CAUTION Take care to distribute any additional loads evenly on the dentist element oe ee T Wai y Dentist element C4 Cabinet The maximum load of the dentist element C4 Cabinet is 2kg 4 4 Ibs 59 06 313 D 3382 D 3382 201 01 13 02 37 9 Dentist element and instrument functions 9 2 General instrument functions General instrument functions 38 Sirona Dental Systems GmbH Operating Instructions C4 The dentist element C4 Cabinet lets you save on space by swiveling it under the work surface after use A CAUTION When stowi
80. ou press the button again the view changes to a QUAD IMAGE STILL IMAGE or BLACK SCREEN etc 59 06 313 D 3382 D 3382 201 01 13 02 93 14 SIVISION 3 14 9 SIROCAM 3 SIROCAM C integrated in the assistant element PC Sirona Dental Systems GmbH Operating Instructions C4 14 9 SIROCAM 3 SIROCAM C integrated in the assistant element PC HE Go oy BE na jan CES Be he a E00 Eel Oe 94 Operation in PC mode using a PC connection and SIDEXIS VIDEXIS To use the PC mode SIDEXIS VIDEXIS must be open The PC mode must be activated on the PC See section 14 10 Switching between VIDEO mode and PC mode Picking up the camera e ALIVE IMAGE opens TOGGLING BETWEEN LIVE IMAGE AND STILL IMAGE e Briefly touch the foot button when the camera has been picked up e When you briefly touch the foot button again lt 1s a LIVE IMAGE reappears 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 14 SIVISION3 Operating Instructions C4 14 9 SIROCAM 3 SIROCAM C integrated in the assistant element PC SAVING A STILL IMAGE IN SIDEXIS VIDEXIS e Save the displayed STILL IMAGE by pressing the foot button for some time gt 1s when the camera has been picked up e ALIVE IMAGE opens again automatically Placing back the camera e The LIVE IMAGE is closed e A STILL IMAGE remains displayed 59 06 313 D 3382 D 3382 201 01 13 02 95 14 SIVISION
81. quick set ting key 1 gt 3 s when all of the instruments are depos ited in their holders You will be prompted to choose between PURGE A APURGE and SANITATION Select APURGE with the or key APURGE must flash SELECT MODE PURGE APURGE SAN 1 The SANITATION function is described in the instructions Care and Cleaning by the Practice Team 59 06 313 D 3382 D 3382 201 01 13 02 55 10 Operation light tumbler filling cuspidor flushing purge 10 5 Purge Auto Purge function purging the water paths A SELECT ITEMS FOR PURGING 56 Sirona Dental Systems GmbH Operating Instructions C4 If you press quick setting key 1 briefly lt 3 s the follow ing prompt will appear if all instruments are in their hold ers SELECT ITEMS FOR PURGING Remove the instruments to be purged from the dentist and assistant elements and insert them in the adapters of the sanitation bowl as far as they will go A CAUTION Be careful not to snap off the instrument hoses when in serting the instruments The maximum water flow must be set on the instru ments Press quick setting key 1 again lt 3 s the instruments are then purged one after the other The purging time in seconds set previously in the Mode dialog 11 14 runs down for each instrument individu ally An audible signal sounds after the last instrument has been flushed You now can continue in either of
82. r ERRES NENS 105 Maimtenant erso aa a a a aeaa aa 106 17 1 Care and cleaning by the practice team cccccccsseececeeeeeeeeceeeeeseueeeeessaeeeeceaaueesesseeeeeaasseeesseneess 106 17 2 Inspection and MAINTENANCE ccceecccesececseeeeceececseneeceeueceseueeeseeeeseaeeeseeeeseaseesecesenseeeeteneeeneeesenes 106 TPS oale Check Serra E E 107 174 Niaintenance Man al aspis Couette ee e 107 59 06 313 D 3382 D 3382 201 01 13 02 5 Sirona Dental Systems GmbH Operating Instructions C4 1 Warning and safety information Warning and safety information Intended use On site installation Maintenance and repair Modifications of the system Combination with other equipment 59 06 313 D 3382 D 3382 201 01 13 02 This dental treatment center is intended for diagnosis therapy and dental treatment of humans by properly trained personnel This unit is not intended for operation in areas subject to explosion hazards The on site installation must have been performed according to our requirements The details are described in the document Installation Requirements As manufacturers of dental medical equipment and in the interest of the operational safety of your system we stress the importance of having maintenance and repair of your treatment center performed only by our selves or by agencies expressly authorized by us Fur thermore components influencing the safety of the unit should always be replace
83. rammable Chair program 0 Entry exit position freely programmable Chair programs 1 and 2 freely programmable Q vortice The four program keys are also used for reprogramming the chair programs 59 06 313 D 3382 D 3382 201 01 13 02 19 4 Controls and functional elements 4 2 Control panel on the assistant element 20 Sirona Dental Systems GmbH Operating Instructions C4 Additional functions light blue keys Tumbler filling ON OFF Cuspidor flushing ON OFF X ray image viewer ON OFF for SIVISION 3 also WHITE SCREEN activation Treatment center sanitation This key can be used to start the treatment center sani tation program see instructions Care and Cleaning by the Practice Team Freely selectable function The function can be preset in the Mode dialog as button or switch Light ON OFF With SPRAYVIT picked up e Instrument light With SPRAYVIT in holder e Operation light 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 5 Putting the system into operation Operating Instructions C4 rN i Putting the system into operation Gl Initial startup The disinfection system adds a disinfectant to the water 1 100 to prevent the formation of microorganisms in the water system Prior to initial startup of your treatment center sanita tion must be performed If the service engineer has skipped the sanitation proce dure af
84. revents the selected mode from being changed inadvertently 11 21 Mode BLOW OUT SPRAY A Ca Mode gt gt Prevents drop formation You can activate the instrument blow out function in this setting option This removes any residual water one to BLOW OUT SPRAY two drops by blowing air through the instrument heads YES NO Just press the or key to switch this function ON or OFF The selected item flashes Q vortice This function is switched OFF in the factory setting notice Sirona recommends activating this function especially for the C3 treatment center 59 06 313 D 3382 64 D 3382 201 01 13 02 Sirona Dental Systems GmbH 12 Assistant element Operating Instructions C4 12 1 Assistant element Assistant element Assistant element The assistant element can be swiveled to the side and to the front To do this grasp the assistant element laterally at the handpiece rack 1 The ease of the swivel movement towards the front can be set with the knob 2 A CAUTION Make sure that the backrest does not collide with the assistant element if you have positioned the latter in the movement range of the backrest Also make sure that the assistant element is not posi tioned above the patient when the chair moves upward on contact with the patient a safety switch stops the movement Removing a handpiece rack with closed suction hand piece holders is described in the document Care an
85. rs Then the current voltage setting of the removed instru ment is displayed Using the keys you can adjust the instrument light voltage from 3 0 to 5 6V in steps of 0 1V Starting at 3 9V WARNING also appears After depositing the instrument please remove and set the next instrument Observe the voltage specified by the instrument manufacturer Q vortice The voltage 3 6V is already preselected for Sirona in struments 61 11 Basic treatment center settings in the Mode dialog 11 13 Mode FUNCTION TOGGLE MOMENTARY A TAKE INSTRUMENT A MAX TORQUE YES NO Sirona Dental Systems GmbH Operating Instructions C4 Setting the torque of the electric motors This Mode dialog is used to set the automatic controller action of the SL or SL ISO electric motors Individual set tings are possible for each motor holder First a message prompting removal of an instrument appears After removing the instrument select the setting dialog by pressing the Mode key again MAX TORQUE If Yes is flashing The motor will attain a higher torque at speeds gt 15 000 rom If No is flashing The running smoothness of the motor will be higher at speeds gt 15 000 rpm Q vortice The new setting becomes effective only after the corre sponding motor is removed again Q vortice Mode FUNCTION TOGGLE MOMENTARY A FUNCTION TOGGLE MOMENTARY Mode PURGE TIME SEC A PURGE T
86. sappears as soon as an instrument is removed from its holder Mode SERVICE ONLY START STOP For service engineers only A SERVICE ONLY START STOP Mode FC CONTROL MODE ON OFF VARIABLE el Biased E gt Direct starter or speed controller foot switch a Presetting of the foot switch control mode for the instru ment start FC CONTROL MODE With direct starter ON OFF presetting the bar dis ON OFF VARIABLE play always jumps immediately to the maximum value when you step on the foot switch You are working with the displayed maximum value With speed controller foot switch VARIABLE pre setting the bar display depends on the pedal position You are working in a range between 0 and the displayed maximum value This setting can be chosen individually for user A or B 11 6 Mode TIME HOURS MIN Setting the time Here you can set the time of day in hours and min utes TIME HOURS MIN The hours display flashes first and can be adjusted with 11 21 G amp G Mode gt the keys 59 06 313 D 3382 58 D 3382 201 01 13 02 Sirona Dental Systems GmbH 11 Basic treatment center settings in the Mode dialog Operating Instructions C4 11 7 Mode DAY MON YEAR When you press the Mode key a second time the minute display starts flashing and can be adjusted in the same way 11 Mode DAY MON YEAR Setting the date Here you can set the year month and day The setting is made
87. sing the handle 1 The head pad 2 is held magnetically A DANGER A strong magnet is integrated in the underside of the head cushion 2 which could affect a nearby cardiac pacemaker Therefore please avoid bringing the magnet in close proximity of a cardiac pacemaker of a patient user or technical personnel In addition direct contact of the head cushion with magnetic cards can lead to a data loss Articulated headrest The headrest must be adjusted manually To do this take the load off the backrest and pull out or push in the headrest using the handle 1 Tilt the headrest backward using the locking button 2 DANGER Tilt the headrest forward by simply pulling it out 59 06 313 D 3382 30 D 3382 201 01 13 02 Sirona Dental Systems GmbH 8 Patient positions Operating Instructions C4 8 3 MultiMotion headrest 8 3 MultiMotion headrest Adjustment to patient s height The headrest can be adjusted to the patient s height by pulling out or pushing in the headrest extension This adjustment is usually required at the beginning of treat ment Q vortice Before positioning the patient on the headrest make sure that the head support has been optimally adjusted to the patient s height This simplifies all subsequent work with the MultiMotion considerably since readjust ment to the patient s height can thus be omitted when changing over from mandibular to maxillary treatment The MultiMotion ena
88. structions C4 16 6 Tray extra equipment Tray extra equipment notice Maximum load 4 kg Q vortice Maximum load 1 kg For further details please refer to the operating instruc tions for the tray REF 33 33 718 59 06 313 D 3382 D 3382 201 01 13 02 103 16 Extra equipment and accessories Sirona Dental Systems GmbH 16 7 X ray image viewer on the dentist element Operating Instructions C4 16 X ray image viewer on the dentist element Extra equipment This X ray image viewer is switched ON or OFF using the illustrated key on the dentist or assistant element control panel To view intraoral dental images the anti glare film 1 must first be attached with two clips Then fasten the intraoral dental images with the third clip over the cut out 16 8 X ray image viewer on the lamp support tube Extra equipment This X ray image viewer is switched ON or OFF using the illustrated key on the dentist or assistant element control panel To view intraoral dental images the anti glare film 1 must first be attached with two clips Then fasten the intraoral dental images with the third clip over the cut out en SE AT i amp 59 06 313 D 3382 104 D 3382 201 01 13 02 Sirona Dental Systems GmbH 16 Extra equipment and accessories Operating Instructions C4 16 9 X ray image viewer on the tray 16 9 X ray image viewer on the tray Extra equipment This X ray image viewer is switched
89. t TUN CONS iar cseiciceiccesncnesticcadencvensint cnmece nbdncebacdadewcsseasnesusedapbawencedenntenmneccsnseceseumesiennene 38 9 3 a 516 1d ea 90 110 eee ee ae en ee E eee ee eee ee ee oeeee 40 9 4 Highspeed handpiece ccccceeececeeceecseeeceecceceueeeseuseceesseeeeeaeceueeeeeeaeceeseeeesaeesenaeeeenseeeseuseseeeeseneass 41 wa GIRO SONGC C Scaler eea E ee eee een eee ee eee eee 41 oe OPRAN VIT ea E E O sce 43 9 7 Saving the instrument PrOGramMs cccccseccccccseececcseeeeccceeeeeececsueeeeesseaeeeeesaueeeeesseeeeesaueeeesseeesensaaees 43 9 8 Placing treatment instruments in their NOIGELS cccccceeeeeeeeeeeeeeeeeeeeeeseeeeeseeeeseeeeeseeeesseeeseeeeees 44 9 9 Surgery with saline solution NACI ccccccccccsssseeceeeeeeeeeseseeeeceeaeeeeeseaseeeeseeeeeesaeeeeeessuseeeseseeeeesaaees 45 910 Satelec Mini LED CUmIAG WOM iscate vin cetsscue ncovemedscasaseaszecaupelavtanenotsesessaceueaagcoauaiianaseennsataateusaeeaeasagens 46 59 06 313 D 3382 D 3382 201 01 13 02 3 Table of Contents Sirona Dental Systems GmbH Operation light tumbler filling cuspidor flushing PUIGE ccceeseeeeneeeeneeeeenes 51 aa fy OPEIN sa tence cert er tr reer rene rrr ern cre eset Cher aan eecno recente ere T 51 102 TUMHE TUNG G58 cea area kee teeeaace asec cen lean eae skank aa ee ee ca cere eee 51 10 3 Tumbler filling with automatic sensor control Special equipment not available in all countries ccceeccecc
90. t electrical shock Degree of protection against ingress of water Mode of operation Year of manufacture Tests approvals 59 06 313 D 3382 D 3382 201 01 13 02 Wu DVGW CE 0123 C4 C4 Cart and C4 Cabinet 230VAC 50Hz 115VAC 50 60 Hz 100VAC 50 60 Hz 4 5A at 230V 9 5A at 115V 11 5A at 100V for 230VAC T 6 3 AH 250 VAC REF 10 77 452 for 100 115 VAC T 10 AH 250 VAC REF 10 77 460 Ambient temperature 10 C 40 C 50 F 104 F Relative humidity 30 75 Air pressure 700hPa 1060hPa Temperature 40 C 70 C 40 F 158 F Relative humidity 10 95 Air pressure 500hPa 1060hPa Class I equipment C Type B applied parts x except CEREC 3D camera SIROCAM 3 SIROCAM C Type BF applied parts Li Ordinary equipment not protected The foot switch has an IPX1 degree of protection against liquids drip proof Continuous operation with intermittent loading corre sponding to the dental mode of working Permanently connected unit wd 0xx on name plate of chair This dental treatment center complies with the require ments of IEC 60601 1 1988 A1 1991 A2 1995 and IEC 60601 1 2 2001 DVGW This unit complies with the technical rules and safety and hygiene requirements for connection to the drinking water supply provided that a disinfection sys tem is integrated This product bears the CE marking in accordance with the provisions of the Cou
91. ter installation of your treatment center on the basis of an agreement with you please perform sanita tion yourself as described in the separate instructions Care and Cleaning by the Practice Team Sanitation takes approx 24 hours Main switch Switch ON the main switch 1 During power up the treatment center automatically performs a self test A CAUTION For safety reasons always switch the treatment center OFF O after consulting hours This cuts off the air and water supply as well as the line voltage Ready for operation After the end of the self test the message READY the time and the last user selected A or B appear on the display READY 10 04 27 After the treatment center is switched on the cursor is between the chair program keys 1 and 2 If a program LED is illuminated then the chair was in a programmed position before switching off If no program LED is illumi nated then the chair was in a non programmed position before switching off The unit is now ready for operation 59 06 313 D 3382 D 3382 201 01 13 02 21 5 Putting the system into operation 22 A MAINTENANCE IN 30 DAYS READY 10 04 27 Sirona Dental Systems GmbH Operating Instructions C4 Display of next maintenance date the next maintenance date is less than 30 days away this message appears each time the unit is switched on see MAINTENANCE Mode dialog After this date has expired the followin
92. the following ways Leave the instruments in the sanitation bowl The treatment center can then be switched off The instruments will automatically be purged as soon as the treatment center is switched on again The APURGE function remains activated The instruments are returned to their holders The treatment center can be prepared for daily practice operation The APURGE function is completed Q vortice When removing the sanitation bowl please notice that it is filled with water 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 11 Basic treatment center settings in the Mode dialog Operating Instructions C4 11 1 Mode key Basic treatment center settings in the Mode dialog Mode key When you press the Mode key you can access and change various basic treatment center settings in a cer tain order They usually apply both to user A and B The corresponding display disappears automatically after approx 10 seconds To exit the Mode dialog more quickly press the Mode key for gt 3 seconds The flashing text is selected and saved when you exit the Mode dialog You can select the desired setting by pressing the or key Key lock The key lock can be activated and deactivated again by pressing the and keys simultaneously The key lock affects the entire control panel of the dentist element Q vortice The key lock can be deactivated only as described abo ve S
93. the tumbler filling and or the cuspidor flushing functions see Mode dia log 11 9 and 11 10 When you press this key a second time the treatment center returns to its previous position memory function Example You have programmed this key for the mouth rinsing position When you press this key the treatment center moves to the programmed position Memory function When you press this key a second time the treatment center returns to its previous posi tion 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH 7 Program selection Operating Instructions C4 7 3 MOVEMENT STOP 1 3 MOVEMENT STOP You can stop the movement of the chair to a pro grammed position as follows e By pressing one of the chair related keys on the dentist or assistant element e By actuating the 4 way foot control e By pushing the 4 way switches on a motorized headrest in any direction All movements of the treatment center are stopped immediately At the same time a double beep signal sounds Please note that when you press the program key of the program which is just running a second time the movement will NOT stop 59 06 313 D 3382 D 3382 201 01 13 02 29 8 Patient positions Sirona Dental Systems GmbH 8 1 Flat headrest Operating Instructions C4 Patient positions Flat headrest The headrest must be adjusted manually To do this take the load off the backrest and pull out or push in the headrest u
94. tion with an integrated SIROCAM 3 The camera handpiece contains data making it possible to restore the factory set color definitions regardless of the dental treatment center where the camera is used Thus the camera can be used at different dental treat ment centers For adjustments e g if you wish to set individual colors you must perform a while balance Select the TAKE VCAM display in the Mode dialog When you pick up the camera the dialog for performing the white balance is displayed There are 3 options available USER individual white balance HOME factory settings can be restored at any time EXIT to exit the WHITE BALANCE dialog The display shows the current camera status i e if an individual white balance was performed the last time USER is displayed in bold type If the factory settings are valid HOME is displayed in bold type The selected item is flashing Select USER with the keys USER starts flashing Set the slide switch 2 of the camera to its middle posi tion overview exposure Then hold the camera so that its lens is located 2 5 cm above a color pattern sheet of your own choice A in the live mode The screen must be completely filled by the focused color area e Press the Mode key to start the white balance takes several seconds If the white balance has been completed successfully USER is displayed in bold type and an audible confirma tion signa
95. uide engages with a click 4 Slip the glare shield onto the light guide It protects your eyes against reflected light 47 9 Dentist element and instrument functions 9 10 Satelec Mini L E D curing light 48 Sirona Dental Systems GmbH Operating Instructions C4 Installation options e inthe dentist element holder 4 or 5 e inthe assistant element holder 1 Handpiece and accessories 1 Handpiece Light guide Supply cable Status LEDs Glare shield ON OFF switch Nn O Oo A Q ND Function button Operating modes The Mini L E D has three different modes To select the desired menu press the function button 4 1 Status LED The status LED signals the following states Color Mode green Normal operation red flashing Overheat protection 4 2 Quick curing mode In this mode the Mini L E D operates at full power for 10 seconds LED 4 2 shows your selection In this mode the light intensity output is approximately as follows 59 06 313 D 3382 D 3382 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions C4 yy Sec A i y p p Sec PLL 4 59 06 313 D 3382 D 3382 201 01 13 02 9 Dentist element and instrument functions 9 10 Satelec Mini L E D curing light e 1100mMW cm 10 with the standard light guide dia 7 5mm e 2000mMW cm 10 with the optional booster light guide dia 5 5mm 4 3 Pulsed curing
96. witching the treatment center off and on again has no effect on this state Mode NACL PUMP OFF or ON for instrument holder Saline solution for the desired burr instrument A eS Mode _ a gt or the SIROSONIC L scaler instrument holder 2 5 NACL PUMP Here you can assign the NaCl pump to a certain instru OFF ment using the keys For preparation of the NaCl pump see page 45 A Q vortice NACL appears on the display in the instrument dialog of the instrument to which the NaCl pump has been as signed NACL PUMP ON FOR HANGER 2 0 norice If you want to assign the NaCl pump to the SIROSONIC L scaler always select holder 5 regardless of the scaler s position in the instrument rack 59 06 313 D 3382 D 3382 201 01 13 02 57 11 Basic treatment center settings in the Mode dialog Sirona Dental Systems GmbH 11 3 Mode MAINTENANCE Operating Instructions C4 Mode MAINTENANCE A drD Display of next maintenance date This dialog displays the number of days until the next maintenance date You should have maintenance perfor MAINTENANCE med by your service engineer at least once annually 360 The instrument running time is indicated in the lower right hand corner of the display for service engineers only As soon as the time remaining until the next mainte nance date is less than 30 days the message is auto matically displayed each time the unit is switched on The display message then di
97. x OPERATING LIGHT When you exit the dialog the last set value is saved The composite key is located next to the SIROLUX key This key is used to switch the operation light ON or OFF with reduced brightness lt 8000 lux You can toggle directly between the intensities by press ing the two keys alternately When the light is ON the green LED in the correspond ing key is illuminated Operation light assistant element e By pressing the light key L you can switch the operation light ON or OFF with the set intensity This is only possible when the SPRAYVIT on the assis tant element is in its holder Tumbler filling When you press this key briefly the tumbler is filled with a preset amount of water When you press the key again during water flow the tumbler filling function is switched off Only for tumbler filling key of the dentist element A Pressing this key for gt 3 seconds displays the settings dialog CUP FILL TIMER CUP FILL TIMER AALL G gt You can set a filling time between 2 and 10 seconds with the keys When you exit the dialog the last set value is saved 59 06 313 D 3382 D 3382 201 01 13 02 51 10 Operation light tumbler filling cuspidor flushing purge Sirona Dental Systems GmbH 10 3 Tumbler filling with automatic sensor control Special equipment not available in all countries Operating Instructions C4 Hydrocolloid continuous operation