Home

User's Manual

image

Contents

1. User s Manual Suitable to supply a 3 phase motor from a single phase 230V 50Hz system For AC automatic controlled Honey extractor equipment Please read the manual before operating the equipment There is danger of electric shock inside the machine during operation Valid from Mar 1 2009 www mezpergeto hu Conditions of using the equipment The equipment can only be used with a 3 phase 230 400 V nominal voltage asynchronous motor Maximal power of motor 250W Do not use motors with higher power than this because it may lead to failure Any damages seen on the equipment electric motor connector or cable the equipment must be examined by an electrician During operation make sure that no liquid gets in the equipment on its cover or any accessories In case it happens the connector must be pulled out of the socket and then the liquid shall be removed from the area If you are not sure about the liquid not being present in the equipment do not apply electricity on the equipment About re starting the equipment ask for the opinion of an expert Any repair works in the equipment can only be done by an electric expert www mezpergeto hu Front panel arranement and switch functions Basic position Grade scale Steps 1 2 3 4 1 2 3 Selection button Stop button Start button At programming Grade scale Steps 1 2 3 4 1 2 3 Next step prog store Speed decrease Speed increase a Automatic shi
2. fting rotating back and forth in two or three steps OOOO OOO The equipment indicates basic position with three short beeps The lighting yellow LED shows the chosen phase The first phase last shorter the fourth phase lasts longer With time the speeds are proportionally increasing closer to the fourth phase This gives opportunity to program the equipment according to the type and consistency of the honey The required values are easily accessible and usable If no one is working in the extractor for start you shall press and release the green buiton www mezpergeto hu w000 COO BB B After pressing and releasing the green START button the first step of first phase starts After passing the first programmed period after braking approx 6 15 second upto the phase the equipment changes direction and new timing begins OOOO Jk B o O After braking and direction change the third timing begins After the third step after braking cycle approx 10 seconds the equipment gets into basic position This is indicated by three short beeps The red LEDs turn to dark only the actual time program is indicated by one of the four LEDs OOOO OOO The control can be stoppen anytime by pressing the red STOP button Then the equipment gets into basic position after the actual braking time In case of keeping the green button pressed by pressing the black button the equipment skips the first phase and works only in two phases The repeated star
3. grammed for normal operation 000 000 b Manual start stop with direction changing possibility After choosing direction of rotation the black button must be pressed long approx 5 sec When the LEDs stop blinking releasing the black button the equipment starts rotating in the shoosen direction Then the greed button can increase and the red button can decrease the speed of rotation When the requested speed is set and later we intend to operate the equipment with this spead press the black button long approx 10 sec until the LEDs go off The equipment stores the setting brakes then it re starts rotation with the set soeed When setting the speed is done turn the equipment off using the supply switch Re connecting the terminals the equipment will use speeds programmed for normal operation Mode selection The equipment is able to operate in two modes a and b Swithcing between the modes is done by continuous pressing the black button When the LEDs stop blinking keep the black button down and press the red button Then the equipment gives a continuous beeping sound Turn the equipment off by the system switch Re connecting the equipment will operate with the other mode Trouble shooting In case rotation does not start after several trials remove the connector from the socket and ask for the help of an electrician In such cases the followings shall be inspected Damages present in the equipment or acce
4. k button One direction Other direction H000 OOO Owe eee Programming speeds a Automatic jogging rotating back and forth in three steps The equipment must be in basic position Press the black button long about 5 sec LEDs start blinking OOOO k Be B Keep the button pressed until the LEDs go off Then releasing the button the motor starts with the speed of the first program step By the START and STOP buttons speed may be increased or decreased in this position start increase stop decrease www mezpergeto hu 000 TI BO p The set speed may be stored by pressing the black button long approx 10 sec OOOO Jok Sees When the LEDs are off the button may be released The set speed is now stored and after the first program step it will operate using this speed set The equipment changes direction and the speed may be set for the next program step Storing the speed is done the same way as before pressing down the black button long until the LEDs go off Then the button may be released In case the button is pressed short shorter than 10 sec the set speed will not be stored it only jumps to the speed of the next step During setting the speed when it reaches the lowest or highest value the LEDs tart blinking and then the other direction may be selected When setting the speeds is done turn the equipment off at the connector By switching the equipment on again it is going to re start with speeds pro
5. ssories that may inhibit starting Voltage present in the socket it worth to try the socket using an other equipment Fuse blown in the equipment cover must be turned manually carefully until it becomes removable Then it may be checked visually www mezpergeto hu When checking the fuse be careful the equipment is not connected to the electric system Input voltage 230V 50Hz Max power consumption 400W Inlet fuse 4A max 5A quick break Outlet voltage 3 x 230V frequency dependant Nominal output power 250W Adjustable range 10Hz 30Hz 500 1300 rpm 2 poles Swithcing frequency 6kHz sinusoidal modulated PWM Control mode non regenerative vectored frequency adjustment Connecting aid QIL fuse fuse QL Lphase i O N phase DLS C B oOo SI E O eU motor O C tev motor Q te W motor www mezpergeto hu
6. ts will be done also in two phases To return to phase three is only possible by removing the equipment from power supply For immediate disconnecting keep the red button pressed while you press the greed button for a moment In this case the braking cycle will be canceled Durations of steps are pre programmed and they are increasing according to the phases In basic position we can jog between phases using the black selection switch In this case one of the four LEDs on the left indicates the actual selected phase The equipment is programmed to the following durations the values are in seconds in the selectable step is in brackets Phase 1 25 40 25 GOO O00 Phase 2 35 45 30 Owo 000 BO p www mezpergeto hu Phase 8 40 65 35 0050 eee Se B Phase 4 90 80 40 0000 OOO Braking times 1 step 2 step 3 step 15 12 10 The numbers are in seconds www mezpergeto hu b Manual start stop with the possibility of direction change 000 00e The equipment indicates basic position with three short beeps By pressing the green start button the equipment starts and runs continuously OOOO eo By pressing the red button the equipment brakes rotation then resets to basic position Braking cycle may be skipped by pressing the start button Warning By pressing start button at the end of the braking cycle the drive may re start In basic position the direction of rotation may be selected by the blac

Download Pdf Manuals

image

Related Search

Related Contents

5VZ 3.4L TRD Supercharger Instructions  Cooper Lighting Lumiere Westwood 913 User's Manual  lire l`article  Imprimez les exercices  Series 90-30 CPU Release, IC693CPU351-EJ, 352-BA, GFK  Owner`s Manual  impianticondizionamento/scheda Sist410Multiflex  Offboard Navigation  Cisco SPA 525 - BayRing Communications  