1. The Company will not be respon sible for any expense incurred for installation removal for service or transportation costs Any such defect should be brought to the attention of the Dealer where the product was purchased and is authorized to repair or replace within the terms of this warranty The Company s only obligation under this warranty will be at its sole option to repair or replace any part proving defective or to refund the purchase price thereof The owner user assumes all other risks if any including the risk of any direct indirect or consequential loss or damage arising out of the use of or inability to use the product The warranty will not apply if in the sole judgment of the Company damage or failure has resulted from accident alteration misuse abuse incorrect installation or operation on an incorrect power source The foregoing is in lieu of all other warranties expressed implied or statutory and the Company neither assumes nor authorizes any person to assume for it any other obligation or liability in connection with said product Light bulbs are not covered in the warranty Service Contact your local dealer for ser vice or warranty information Recycling For electrical products sold in the European Community At the end of the electrical product s useful life it should il not be disposed of with household waste Please recycle where facilities exist Check with your L
2. inside the framing construc tion Plug the fireplace into a 10 Amp 240 Volt outlet If the cord does not reach you may use a 3 core type extension cord rated for a minimum of 10 Amps Existing Fireplace 1 Seal all drafts and vents with a non fibrous insulation mate rial to prevent any chimney debris from falling onto the fireplace Do not install into an existing fireplace that is prone to dampness 2 Cap the top of the chimney flue to prevent rain from entering 3 Plan your electric power sup ply 4 The power cord can run along the front of the hearth to an outlet near the fireplace amp CAUTION Clearance for air circulation beneath the fireplace insert is provided by two spacers Do not install the fireplace insert directly on carpet or similar sur faces which may restrict air circulation If installing the fireplace in a carpeted area place a one piece solid flat surface under the fireplace insert Ensure that all three of the insert s feet rest securely on this surface www dimplex com Operation Figure 4 Manual Control The manual controls for the fireplace are behind the access panel located at the bottom of the fireplace Figure 4 A Flame Action Control Turn the flame action control knob to adjust the flame speed to the desired level B Interior Light Control Turn the interior light control knob to increase or decrease the brightness of the inter
3. local building codes and other applicable regulations to reduce the risk of fire electric shock and injury to persons Do not attempt to wire your own new outlets or circuits To reduce the risk of fire electric shock or injury to persons always use a licensed electri cian Install the fireplace assembly into the mantel refer to mantel as sembly instructions NOTE A 10 Amp 240 Volt circuit is required A dedicated circuit is preferred but not es sential in all cases A dedi cated circuit will be required if after installation the circuit breaker trips or fuse blows on a regular basis when the heater is operating Additional appliances on the same circuit may exceed the current rating of the circuit breaker IMPORTANT If not using a Dimplex mantel the fireplace must be installed in an enclo sure with the following MINI MUM dimensions Figure 3 New Wall Construction 1 Select a suitable location that is not susceptible to moisture and is away from drapes furniture and high traffic Place the fireplace in the desired location to see how it will look in the room Mark the desired location on the floor 4 Fireplace Installation 4 Use studs to frame an open ing of 680 mm wide X 585 mm high X 229 mm deep Option 1 The power cord can be run from behind the trim and along the wall to an outlet near the fireplace Option 2 A new outlet can be installed
4. Owner s Manual Model DF2608 EU DF2608 AU 6904700000 LOL iG Ge eS ei ae IMPORTANT SAFETY INFORMATION Always read this manual first before attempting to install or use this fireplace For your safety always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage 7209340100R03 Table of Contents i Welcome amp Congratulations 3 iN IMPORTANT INSTRUCTIONS 4 4 Site Selection and Preparation 6 4 Fireplace Installation 7 Operation 002 eee ees 9 Maintenance eseeee 11 D Warranty asannnnnnnnnnnnnnn 14 Always use a qualified technician NOTE Procedures and or service agency to repair techniques that are this fireplace considered important enough to emphasize CAUTION Procedures and techniques which if not carefully followed will result in damage to the equipment WARNING Procedures and techniques which if not carefully followed will expose the user to the risk of fire serious injury or death 2 www dimplex com Welcome amp Congratulations Thank you and congratulations for choosing to purchase an electric fireplace from Dimplex the world leader in electric fireplaces Please carefully read and save these instructions amp CAUTION Read all instructions and warnings carefully before starting installation Failure to follo
5. a different battery type if inserted incorrectly if all the batteries are not replaced at the same time if disposed of in I Maintenance 44 WARNING Disconnect the power before attempting any maintenance or cleaning to reduce the risk of fire electric shock or damage to persons Light Bulb Replacement Allow at least five minutes for the light bulbs to cool before touching them to avoid accidental burn ing of the skin The light bulbs need to be replaced when you notice a dark section of the flame or when the clarity and detail of the log ember bed exterior reduces There are three bulbs under the log set which generate the flames and embers and two bulbs above the log that illuminate the log exterior Lower Light Bulb Requirements Quantity of three clear chande lier or candelabra bulbs with an a fire or if an attempt is make to charge a battery not intended to be recharged E 14 small socket base 60 Watt rating Do not exceed 60 Watts per bulb Helpful Hints It is a good idea to replace all light bulbs at one time if they are close to the end of their rated life Group replacement will reduce the number of times you need to open the unit to replace light bulbs Care must be taken when removing the log set as the log set contains LED s and wires To access the lower light bulb area 1 Slide fireplace out of mantel 2 Lay unit on it s back for safe removal of front glass 3 Remove four P
6. des instructions for selecting a location and preparing the site to install the fireplace into your Dimplex mantel surround 1 Selecta suitable location that is not susceptible to moisture and is away from drapes furniture and high traffic 2 For ease of electrical hook up you may wish to locate the fireplace near an existing outlet refer to NOTE 1 3 Store the fireplace in a safe dry and dust free location Figure 2 695 mm amp CAUTION Clearance for air circulation beneath the fireplace is provided by two spacers DO NOT INSTALL FIREPLACE DIRECTLY ON CARPET OR SIMILAR SURFACES WHICH MAY RESTRICT AIR CIRCULATION If installing the fireplace in a carpeted area place a one piece solid flat surface under the fireplace Ensure that all feet rest securely on this surface NOTE The dimensions of the fireplace are 667 mm wide X 575 mm high X 222 mm deep The fireplace does not require any additional venting With trim the dimensions are 695 mm wide X 596 mm high X 222 mm deep www dimplex com Figure 3 4 Fireplace Installation WARNING Ensure the power cord is not installed so that it is pinched or against a sharp edge and ensure that the pow er cord is stored or secured to avoid tripping or snagging to reduce the risk of fire electric shock or injury to persons Construction and electrical outlet wiring must comply with
7. e fireplace out of mantel 2 Lay unit on it s back for safe removal of front glass 3 Remove four Phillips screws from right side of trim 4 Remove trim 5 Slide glass to the right side of the fireplace to remove Figure 6 6 Upper bulbs located in the upper left and upper right corners of fireplace 7 Remove upper light block by removing the four 4 mount ing screws 8 Unscrew bulbs counter clock wise 9 Insert new bulbs 10 Re install upper light bracket 11 Lay unit on it s back slide front glass back into position and attach trim Glass Cleaning The glass is cleaned in the factory during the assembly operation During shipment installation handling etc the glass may col lect dust particles these can be removed by dusting lightly with a clean dry cloth To remove fingerprints or other marks the glass can be cleaned with a damp cloth To prevent scratching do not use abrasive cleaners or spray liquids on the any surface Fireplace Surface Cleaning Use a cloth dampened with warm water only to clean painted sur faces of the electric fireplace Do not use abrasive cleaners SG Warranty Dimplex Electric Fireplaces are tested and inspected prior to shipment and are guaranteed from defect to the purchaser of each new product Any part which proves to be defective in material or workmanship under normal use within one year will be repaired or replaced without charge
8. e for their safety The appliance must be positioned so that the plug is accessible Always unplug the electric fireplace when not in use If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a qualified person in order to avoid a hazard Do not operate any unit with a damaged cord or plug or if the heater has malfunctioned or if the electric fireplace has been dropped or damaged in any manner Return heater to authorized service facility for examination electrical or mechanical adjustment or repair Do not use outdoors Do not use this fireplace in the immediate surroundings of a bath a shower or a swimming pool Do not install the fireplace directly on carpet or a similar surface which may restrict air circulation beneath the unit 3 Do not run the cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away from traffic area and where it will not be tripped over Do not locate the heater immediately below a fixed socket outlet 5 Do not locate the appliance in front of a fixed socket outlet www dimplex com amp IMPORTANT INSTRUCTIONS To disconnect the fireplace turn the controls off then remove the plug from the outlet Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage to the heater To prevent a
9. hillips screws from the right side of trim 4 Remove trim 5 Slide glass to right side of g Maintenance Figure 6 Log Set Glass fireplace to remove Figure 6 6 Pull the front edge of the plas tic ember bed or plastic grate up and forward until the rear tab releases from the ledge located at the bottom of the mirror Figure 7 7 Remove flicker rod by slid ing flicker rod to the left away from the flicker motor and lifting out 8 Remove light bracket for easier access to light bulbs IMPORTANT Only handle the log set by the ember bed NOTE Log set fits tightly into firebox some force may be nec essary to remove 9 Set log set in front of fire place Figure 7 Front Edge Side Section 10 Unscrew bulbs counter clock wise 11 Insert new bulbs 12 Replace the log set by insert ing the front edge of the fireplace and push down on the rear edge of the ember bed until it snaps into place Figure 7 13 Lay unit on it s back and slide front glass back into position and attach trim NOTE Ensure the log set is installed tightly under the back ledge to prevent light leakage Upper Light Bulb Requirements Quantity of two 2 clear chande lier or candelabra bulbs with an E 14 small socket base 25 Watt rating Do not exceed 25 Watts per bulb www dimplex com Maintenance To access the upper light bulb area 1 Slid
10. ior light C Level 1 Heat Provides heat output from one element D Level 2 Heat Provides heat output from both elements NOTE This switch must be in the ON l position for heater to operate with or without heat E Heater Thermostat Control To adjust the temperature to your individual requirements turn the thermostat control clockwise all the way to turn on the heater When the room reaches the desired temperature turn the thermostat knob counter clock wise until you hear a click Leave in this position to maintain the room temperature at its setting For additional heat turn clockwise until you hear the click again and the heater will turn on To turn the heater off rotate the knob fully counter clockwise F Main Three Position Switch The switch has two ON positions marked with 5 and I The I position is for manual operation In this position the built in remote control is by passed The A position is for operating the unit with the provided remote control When in E position the unit is operated with the ON and OFF buttons of the remote control When the switch is in the center Operation position the unit is off Resetting the Temperature Cut off Switch This unit is equipped with a ther mostat which controls the tem perature of the room by turning the heater on and off The heater is protected with a safety device to prevent overheating Should the heater overheat an automa
11. ocal Authority or retailer for recycling advice in your country e product complies wit C the European Safety Stan dard EN60335 2 30 and the European Standard for Elec tromagnetic Compatibility EMC EN55014 EN61000 and EN50366 hich cover the essential require ments of EEC Directives 2006 95 and 2004 108 14 www dimplex com
12. possible fire do not block air intake or exhaust in any manner Do not use on soft surfaces like a bed where openings may become blocked All electrical heaters have hot and arcing or sparking parts inside Do not use in areas where gasoline paint or flammable liquids are used or stored or where the unit will be exposed to flammable vapors Do not modify the electric fireplace Use it only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 21 Avoid the use of an extension cord Extension cords may overheat and cause a risk of fire If you must use an extension cord the cord must be 3 core type and have a rating no less than 10 Amps Do not burn wood or other materials in the electric fireplace 3 Do not strike the fireplace glass Always use a certified electrician should new circuits or outlets be required 65 Always use properly grounded and fused outlets Disconnect all power supply before performing any cleaning maintenance or relocation of the unit When transporting or storing the unit and cord keep in a dry place free from excessive vibration and store so as to avoid damage gt WARNING In order to avoid overheating do not cover the heater The heater carries the Warning Symbol indicating that it must not be covered SAVE THESE INSTRUCTIONS S Site Selection and Preparation This section provi
13. tic cut out will turn the heater off and it will not come back on without being reset It can be reset by switching the Main Switch to O and waiting 5 minutes before switching the unit back on amp CAUTION If you need to con tinuously reset the heater unplug the unit and call customer service Please have your model and se rial number ready when calling NOTE The heater may emit a Slight harmless odor when first used This odor is a normal con dition caused by initial heating of internal heater parts and will not occur again Remote Control Figure 5 The fireplace is supplied with an integrated on off remote control Where the maximum rage of use is 5m WARNING It takes time for the receiver to respond to the transimitter Do not press the but tons more than once within two seconds for correct operation NOTE Ensure that the fire place 3 position switch is set to the remote control setting up position To operate push the ON button to turn fireplace on push the OFF button to turn the fireplace off Battery Replacement To replace the battery 1 Slide battery cover open on the back of the remote control 2 Install AAA batteries into the remote control 3 Replace the battery cover Discard leaky batteries Dispose www dimplex com Operation of batteries in the proper manner according to provincial and local regulations Any battery may leak electrolyte if mixed with
14. w these instructions may result in a possible electric shock fire hazard and will void the warranty Please record your model and serial numbers below for future reference model and serial numbers can be found on the Model and Serial Number Label of your fireplace Figure 1 Model Number Serial Number amp IMPORTANT INSTRUCTIONS When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following Read all instructions before using this appliance 2 This fireplace is hot when in use To avoid burns do not let bare skin touch hot surfaces The trim around the heater outlet becomes hot during heater operation Keep combustible materials such as furniture pillows bedding papers clothes and curtains at least 0 9 m 3 feet from the front of the unit 3 Extreme caution is necessary when any heater is used by or near children or invalids and whenever the unit is left operating and unattended 4 Young children should be supervised to ensure that they do not play with the appliance This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsibl

Download Pdf Manuals

image

Related Search

Related Contents

Mode d`emploi du dossier RAEP - Ministère de la Culture et de la  取扱説明書 - TAIYO  Bedienungsanleitung  Serie K . Módulos R2,R4,R6  Top One - Manual  Experiment 4 ()  Unytouch U41-T190DR-SBL touch screen monitor  Magelis HMISTU655/855 - Manuale dell`utente - 07/2013  Télécharger  Joseph Matthew (Matt) Green  