DC4000 – Installation Manual HHO Plus, Alternative Energies, Ltd
Contents
1. 8 000 cc 1 6 20 0 22 0 9 000 CC 1 8 23 0 25 0 10 000 CC 2 0 26 0 28 0 5 000 CC 1 0 6 0 7 0 6 000 CC 1 2 715 8 5 gt 7 000 CC 1 4 8 0 9 5 E a ee eel o 8 000 cc 1 6 9 5 11 0 9 000 CC 1 8 10 5 12 5 10 000 CC 2 0 12 0 14 0 RSS sSs e q q e e e e e e e a The values presented in the table may have a variation of 15 according to the different driving and mechanical conditions of each truck For example using KOH as electrolyte with 90 purity we should start using a concentration of e 12Volts 2 in the water solution 20 g liter e 24Volts 5 in the water solution 50 g liter You should right after measure the current intensity going into the generator and increase slowly the concentration until you reach the first standard operation amperage 26 0 A 12V or 12 0 A 24V example for a 10 liter engine see table above The HHO generator will start producing HHO gas and temperature will increase with time making higher the electric conductivity of the solution and amperage until we reach the final standard operation 28 0 A 12V or 14 0 24V example for a 10 liter engine see table above Warning Do not fall in the temptation of not measuring the current or increase the electrolyte concentration more than is advised in this manual because in long term the generator will not work properly and you may also not save any fuel HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de
2. _ Em Engine HHO Tank HHO Gas i Air Intake Manifold Water Materials to make the connection 2 High pressure hose ae E Barb to port fitting threaded elbow Sequence of parts to make the connection Extra materials x Teflon tape Plastic clamps HHO connection from the bubbler to the air intake manifold HHO Tank HHO Gas Air Intake Manifold Water Materials to make the connection 1 1 1 High pressure hose Security check valve Barb to port fitting Barb to port fitting threaded elbow Sequence of parts to make the connection Extra materials Teflon tape Plastic clamps Water connections between the water tank and the dry cell HHO Tank HHO Gas Air Intake Manifold Materials to make the connection r 1 1 Cristal pvc hose Barb to port fitting Barb to port fitting threaded elbow Sequence of parts to make the connection Extra materials Teflon tape Plastic clamps Electric connection from the battery to the relay Position 30 Electrics gnition Source be Ground Ground Ground Materials to make the connection 1 1 1 Ring crimp terminal Red electric cable Female crimp Relay 1 1 Blade type car fuse Blade fuse holder Sequence of parts to make the connection Bla a7 B w Electric connection from the ignition source to the relay Position 85 Ign
3. parameters For example If the accelerator pedal is pressed further down this will open the throttle body and allow more air to be pulled into the engine The ECU will inject more fuel according to how much air is passing into the engine A mass air flow sensor MAP or MAF is used to find out the mass of air entering a fuel injected internal combustion engine The mass air flow information is the most important one and necessary for the engine control unit ECU to balance and deliver the correct fuel mass to the engine Older Trucks Mechanical Pump Before electronics most engine parameters were fixed A mechanical injection pump determined the quantity of fuel per cylinder per engine cycle Like mentioned before when adding a HHO gas to these trucks we will see immediate improvements in fuel consumption There are no special devices or requirements to fit the HHO System to these trucks but to improve the fuel savings the injection rate of the fuel pump should be tuned to the new air fuel mixture conditions Modern Trucks Electronic Fuel Injection The ECU of your truck is the brain using mapped data to work out the optimum control conditions for the engine According to the day to day driving conditions the ECU builds a memory data base that helps it to decide the course of action that should be taken by the engine to ensure an ideal drive Even though you have made modifications in your truck the ECU still continues to get an input
4. Outubro 42 2430 769 Vieira de Leiria l Portugal Email info hhoplusgas com Telephone 00 351 244 697 116
5. key permanently in that position Try never to make this kind of connection because it increases the risk of some explosion to happen Dry Cell electric connections Inside each one of the Dry Cells we have 29 plates 5 of those with a configuration that allows the insertion of yellow female spade connectors Not all of the plate are connected because electrolysis would in this case be very intense and damage the surface of the plates We have to leave between the positive and the negative some plates without connections Neutral plates in order to break the voltage and increase the electrolysis efficiency with less heat production Please refer to the picture below for typical wiring connection of the dry cells using 12 or 24v Never use the Dry Cell using 24V and the 12V configuration Electrolysis will be very intense and you will damage the system in a short period of time The positive circuit red wire should be connected to the Relay Switch position 87 Some relays present the position 87a Leave this connection with no connections Connect the negative circuit black wire of the Generator to a good ground source HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com G HHO Plus DC4000 Installation Manual Water and electrolyte setup Principles of the water electrolysis Electrolysis of water is the decomposition of
6. pages of this manual you will be able to check each one of the individual connections to be made regarding the installation of the electrical circuits We will now only focus on the main aspects of the installation now Ignition Source Ground e DC Battery Battery The system is powered by the 12 24V battery and controlled by the relay switch The system will only work if there is a signal from the ignition source The positive circuit red wire should be connected to the Relay Switch position 30 Identifying the ignition source This is an important connection to be made in order to have the generator working only when the engine is also working Identify a point in your vehicle s electrical system which has 12 24 Volts positive present only when the engine is running The most secure connection is to excitement signal of the alternator If you do not know how to do this connection please ask you mechanic to do it for you Connect this electric source to the Relay Switch position 85 This circuit will control the HHO production HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com Qi m HHO Plus DC4000 Installation Manual This electric connection can also be made to a circuit controlled by the ignition key position 2 but there is a risk of hydrogen being produced when the engine is not running if you leave the
7. see immediate economies in fuel consumption However this is not the case for some electronic fuel injected vehicles equipped with an engine control unit ECU because the fuel burned inside the cylinders has significantly improved but the sensors continue expecting the same amount of unburned oxygen to come out of the exhaust of the engine This causes a signal to be fed back to the ECU that after will give orders to inject more fuel increasing the air fuel mixture Richer which will counter act the fuel gains you may be expecting Components An Electronic Control Unit ECU controls the internal combustion operation of the engine The simplest ECUs only control the quantity of fuel injected into each cylinder per engine cycle The more advanced ECUs HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com ay HAO Plus DC4000 Installation Manual also control the ignition timing variable valve timing VVT the level of boost maintained by the turbocharger and other engine peripherals ECUs determine the quantity of fuel ignition timing and other parameters by monitoring the engine through sensors In trucks the most important sensors are the MAP MAF airflow and temperature sensors Some trucks have also oxygen sensors lambda sensors For an engine with fuel injection the ECU will set the quantity of fuel to inject based on a number of
8. the pictures below HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com en Fe HHO Plus DC4000 Installation Manual Positioning the Bubbler The bubbler will serve two purposes cleaning the HHO gas and act as a safety barrier When HHO gas is produced from the dry cell some small water vapor is produced as well because the water will get a little bit hot with the passage of current This water vapor can carry tiny particles of electrolyte which can cause damaging corrosion As the HHO bubbles rise up the column of water inside the bubbler they are scrubbed of any electrolyte particles that were attached to the water vapor The result is much cleaner HHO gas In the event of a flashback the bubbler also acts as a safety barrier If a flame reaches the bubbler and ignites the HHO that has accumulated at the top the water column will prevent the HHO from going on to the dry cell because the flame cannot skip from bubble to bubble Make sure that bubbler is installed 20 cm above the water tank to accomplish the gravity head needed for a correct filtering of the HHO gas Please take a look at the pictures below HHO from Water Tank HHO to the Engine HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com n r
9. DC4000 Installation Manual HHO Hydrogen on Demand Dual Fuel Generator Systems HHO Plus Alternative Energies Ltd Technical Department Travessa das Serras 33 Vieira de Leiria Portugal T 00 351 244 697 116 E info hhoplusgas com HHO Plus CONTENTS Safety Precautions Important Information Safety Equipment Enjoy your new system Installation of the hydraulic components General configuration Positioning the Dry Cell Positioning the Water Tank Positioning the Bubbler Positioning the water and HHO hoses HHO injection point Installation of the electrical components General configuration Battery Identifying the ignition source Dry Cell electric connections Water and electrolyte setup Principles of the water electrolysis Electrolyte concentration Water levels in the tank Amperage variation in the system Electronic fuel injection Basic Information HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com DC4000 Installation Manual 10 11 11 alal 11 12 13 13 13 15 15 16 16 HHO Plus DC4000 Installation Manual Components 16 Older Trucks Mechanical Pump 17 Modern Trucks Electronic Fuel Injection 17 Resetting the ECU Option1 18 Resetting the ECU Option 2 18 Test run and checking your work 18 Maintenance 19 Check list for HHO system debugging 19 Import
10. Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com en z HHO Plus ALTERNATIVE DC4000 Installation Manual Important Remember that we are not changing diesel fuel for another type of fuel We just want to put enough HHO gas inside the engine to allow the normal diesel fuel to burn better thus increasing fuel economy If we put too much hydrogen we may not have any positive results because we will be forcing the alternator and engine without increase in fuel efficiency Another thing that should consider is steam Some of the early cell developers run their units with so much amperage that the unit was producing more steam than HHO If your unit runs hot to the touch you must suspect that at least part of your output is steam One way to test for steam is to run your gas outlet over some ice If you get significant amounts of fog forming water droplets you know that at least part of your output is steam Water levels in the tank Once you have your mixture ready pour it into the top of the water tank up to the water level line shown in the picture bellow Try to only fill your unit about 70 full This is imperative to allow the HHO produced to enter the gap left in the Tank and avoid any risks of some water getting into the engine The standard water tank is a 12 liters unit which will provide you with approximately 2500 kilometers of driving Be sure to make your maintenance plan wi
11. N HHO Plus DC4000 Installation Manual Positioning the water and HHO hoses The hose connections on vertical position of the dry cell do not require any special remarks The water intake is connected in the bottom and HHO output will be in the top of the cell You just need to make sure that the HHO output hose is always above the top of the cell If not the HHO gas will have difficulties moving outside the cell and the production will be reduced Please refer to the illustration below for typical installation of the hoses coming and going from the water tank o A y Bud F me Pac N NN The hose connections on horizontal position of the dry cell require only that the positioning of the HHO output hose be made always on a uprising position without ups and downs If this happens the HHO gas will have problems moving into the water tank and will also be released gulps reducing the efficiency of the system You may verify this problem if fluctuation of the amperage on your system is very high Please refer to the illustration below for typical installation of the hoses coming and going from the water tank HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com Fe HHO Plus DC4000 Installation Manual HHO injection point The system is operated by vacuum suction from your truck s air intake which takes the HHO directly to the co
12. ant information 19 Check List 20 Parts positioning 22 HHO connection from the water tank to the bubbler 23 HHO connection from the bubbler to the air intake manifold 24 Water connections between the water tank and the dry cell 25 Electric connection from the battery to the relay Position 30 26 Electric connection from the ignition source to the relay Position 85 27 Electric connection from the relay Position 86 to the Ground 28 Electric connection from the relay Position 87 to the dry cell 29 Electric connection from the dry cell to the ground 30 HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com G HHO Plus DC4000 Installation Manual Safety Precautions Important Information Read and follow these safety precautions to avoid hazards If you do not understand these instructions or do not like to work on vehicles please have a qualified mechanic do the installation for you Incorrectly installing or using the HHO System may result in serious damage to you and or your vehicle It should take approximately 3 hours to install this unit so ensure that you have enough time to complete the installation Be sure to work outside no smoking at any time during the installation make sure the engine is off and very importantly not hot Your HHO System does not store hydrogen subsequently there is no fire hazard when installed properly Howev
13. ave too much electrolyte electrolytes are KOH Potassium hydroxide and NaOH caustic in the system that is eating soda the generator plates too fast Remove the water immediately The more electrolyte you add to the water the more amperage you nd start all over again will have in the system and also more HHO gas will be produced But It is false to assume that a higher HHO gas production will mean a higher fuel savings There is an optimum point for all internal combustions engines In diesel trucks the system should provide around 0 2 liter min of HHO gas per each 1000 cm3 of engine displacement You will be meeting this standard running your generator with HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com HHO Plus ESSE O EEE ES SS CANDEIAS EI CTIS EPOCA AEF T CNA PCa PEE aS ENS ORT SRE SRT eT PGR E ESSES TSC CE CEEE On Oe Oe oe Engine Size HHO liter min Start Amperage A Final Amperage A f Jona nanan nn nnn anna nnn nanan f H fanaa 5 000 CC 1 0 12 0 14 0 DD O E nnd 6 000 cc 1 2 15 0 17 0 e e paro ce ae m mea are a sa gt 7 000 CC T4 17 0 19 0 IN RR J nnn nnn ne panna nnn nnn nnn nnn nnn
14. d fuel it causes the flame speed to increase This allows more of the fuel to burn during the power stroke This will just happen And it will be a dramatic increase over the combustion without the HHO After the combustion efficiency is improved the ECU is often fooled by the reduced quantity of unburned hydrocarbons and increased oxygen content and often will add fuel to compensate This can ruin your mileage gains The simplicity of what we have to do to have a successful HHO installation is get some HHO into the engine and adjust the sensor inputs as necessary so the ECU is not blocking the gains That s all HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com ay HHO Plus DC4000 Installation Manual If we can do those 2 things we will always get vastly improved fuel economy and vastly improved decreased emissions While this checklist was written with HHO users in mind it will work for any other technology that improves combustion efficiency You will find that you can adapt many of these steps to apply to whatever technology you are using to debug your project Other combustion technologies include but are not limited to water vapor injection fuel preheating fuel vaporizers atomizers fuel cracking technologies using additives to break down the fuel etc You should check out these items working from the top down They have been order
15. e what it learned about the system when it was inefficient and start over again with the new improvements installed You can reset your computer by disconnecting your battery ground wire from the car and leaving it off overnight then reconnecting it again 8 Is there something else mechanically wrong with your engine If your engine is working properly adding an HHO system will not correct that You will often find that if your engine is not working properly just fixing it can give you a dramatic increase in fuel savings all by itself If you had any kind of check engine light before starting the project you should get this fault explored and handled If you re not sure reset your computer turn off all of your HHO extender and any other added modifications and see if you still get a fault code If so get it fixed first before adding your modifications All vehicles can be solved Some of them are a little tougher than others due to the way the ECU was programmed But they can all be solved The technology works If you have gotten to this point and your vehicle is still not been solved one of the above steps is still out You need to find it and get it corrected And then your results will shine through HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com Parts positioning HHO connection from the water tank to the bubbler HHO Gas De fio
16. ed this way on purpose so that the most likely problems are higher on the list Also the problems that are the easiest to test appear higher on the list than those that are difficult and or expensive to test for The thing you have to realize is that the technology works And because it does all vehicles can be solved If you are having a hard time getting the results you should you just need to go through these items and find the reasons your gains are being blocked If you keep at it you will find the problem and you will get the gains you are seeking Check List 1 Is your device making HHO The most common bug we encounter trying to debug systems is that HHO is not being produced or is not getting into the engine for some reason Check your system Measure the output of your HHO cell by doing a water displacement test Remember that the system should provide o 2 liters min of HHO per each 1000 cc in the engine See if you are meeting that standard 2 Is the HHO gas getting into the engine We have seen cases where a leak in the system was keeping the hydrogen from getting into the engine A split hose can cause this or one that is not attached at all A check valve oriented in the wrong direction can block the HHO from getting to the engine One time we found that the lid to a dry cell s reservoir had a leak and when this was fixed the situation resolved completely Spray your hoses and connections with soapy water to expose any leaks in you
17. er water electrolysis generates Hydrogen an explosive gas which means that you should never light a match or smoke near or in front of the generators output the water tank could blow up Be careful with the generator working when the car is not moving A small amount of hydrogen can accumulate in the air intake of the motor and could explode if you smoke or use an open flame near it Safety Equipment Be sure to wear goggles and rubber gloves and only use professional tools use common sense and general safety procedures used for any work carried out on automotive installations and maintenance Enjoy your new system Be safe and enjoy your new Hydrogen on Demand Dual Fuel Generator System read and understand these instructions before and during the installation and you will benefit from your new system for years to come HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com en Fe HHO Plus DC4000 Installation Manual Installation of the hydraulic components General configuration Please refer to the illustration below for typical configuration of the mechanical and hydraulic parts of the HHO system In the end pages of this manual you will be able to check each one of the individual connections to be made regarding the installation of the components We will now only focus on the main aspects of the installation now HHO Tank A
18. g directly to the sky If you look carefully the cell has 2 openings one higher than the other The lower opening is for the water intake and the upper opening for HHO gas output We must make sure that the cell is not placed with an angle rotation that reduces the distance between the two openings Please take a look at the pictures below HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com HHO Plus ho If the Dry Cell is placed as shown in the image on the right you will not use 100 capacity of the generator to produce HHO gas Also the HHO gas will have problems getting out of the cell being released gulps You can verify this problem if fluctuation of the amperage is very high Make sure to install the Dry Cell in a place that can easily be accessed and inspected from time to time It should be mounted and secured in such a manner as to ensure it does not move or bounce around while the truck is moving even over rough terrain Securing it with a permanent bracket should be sufficient to secure it to the engine chassis and to operate perfectly Positioning the Water Tank Make sure that water tank is installed with the same care as described before for the generator The water tank needs to be placed 20 cm above the HHO dry cell to accomplish the gravity head needed for the water hydrogen to flow into the generator Please take a look at
19. have done everything right within a short time you will notice that the engine starts to sound different It will sound smoother and quieter Your RPM s may be unstable for a couple of seconds This is normal the HHO is starting to change the combustion cycle and the engine is now adjusting to the addition of the mixture Your RPM s should now normalize after a couple of minutes Maintenance Regular Maintenance depending on your driving every week you should check the water level inside the water tank and also the amperage Refill with water and add a little more electrolyte to allow amperage to be at normal operational values Verify that all parts are of the system are perfectly placed and in good working conditions Winter Maintenance If temperatures drop below 4 C you should add 20 25 isopropyl alcohol to the water solution in order to avoid water from freezing even with the more severe temperatures Don t use another type of alcohol or you risk damaging the stainless steel plates Annual Maintenance Every year you should clean the water tank and drycell and remove all deposits Add 50 isopropyl alcohol to the water solution and leave it in the system without working for 24 hours Flush the system and add some fresh water to remove all deposits Check list for HHO system debugging Important information HHO will improve combustion efficiency This is a scientific fact When introduced into the engine along with the petroleum base
20. ir Intake Manifold Positioning the Dry Cell You will need to find a good place in the back of the driver s cabin to mount your new HHO system Please remember that the water tank should be placed at least 20 cm above the generator Dry Cells in order to guarantee a sufficient water head for the water hydrogen to flow HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com 3 HHO Plus DC4000 Installation Manual Please take in consideration also that in some trucks the cabin has sometimes to be lifted in order to allow access to the engine and or other mechanical parts If the positioning of HHO System is not made considering this fact there is a risk that some water may flow into the engine or break any hose connection when the cabin is lifted Please study carefully the following photos The dry cell can be mounted in horizontal or vertical position The vertical position does not require any special remarks The water intake is connected in the bottom and HHO output will be in the top of the cell You just need to make sure that the HHO output hose is always above the top of the cell If not the HHO gas will have difficulties moving outside the cell and the production will be reduced The horizontal position requires more care in the installation The cell has to be positioned upright and leveled to the ground with the tube fittings facin
21. it warms up This would not take more than 10 minutes at the most in summers Once you have done this you have accomplished the ECU resetting Shut off the engine You can now use your car whenever you feel like ECU resetting is over Test run and checking your work Start by checking all your connections Make sure your inline fuse has been installed and everything is in the right position Now start your engine While it s running watch for bubbling action inside the hose coming from the dry cell and back to the water tank Please check the amperage in your system The generator was made to run at 22 5A without overheating If you have a higher amperage values you must remove some water electrolyte from the water tank and add only water in order to reduce the concentration and consequently the amperage Please verify the starting amperage settings presented previously according to your engine size HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com G HHO Plus DC4000 Installation Manual If there is a high variation of the amperage readings then there is some problem causing hydrogen to have difficulties getting out of the cell Please verify the cell and hoses good positioning Please verify if there is not too much foam being produced In the beginning you may need to change the water after sometime having the generator working If you
22. ition Source o Ground DC Battery Ground Materials to make the connection 1 1 1 Female crimp terminal Red electric cable Female crimp terminal Relay Sequence of parts to make the connection Electric connection from the relay Position 86 to the Ground Electrics Ignition Source Ai Fuse X Ground DC Battery Ground Materials to make the connection LU Es 1 1 Female crimp terminal Red electric cable Ring crimp terminal Relay Bla 81 Sequence of parts to make the connection Bla 47 B 7 Electric connection from the relay Position 87 to the dry cell Electrics Ignition Source N gt Fuse Ground DC Battery Ground Ground Materials to make the connection 1 1 1 Female crimp Red electric cable Snap lock splice terminal connector Sequence of parts to make the connection Electric connection from the dry cell to the ground Electrics Ignition Source Ground a DC Battery Materials to make the connection Ss de PF 1 1 1 Ring crimp terminal Black electric cable Snap lock splice connector Sequence of parts to make the connection B F q Ro N HHO PLU HHO Plus Energias Alternativas i VAT Id Number PT sto 055 036 Headquarters a 4 Travessa das Serras 33 2430 720 Vieira de Leiria Portugal Production Plant Rua 5 de
23. mbustion chamber mixing it with the air fuel The injection point must be done right after the air filter box and in modern trucks after the MAF MAP sensor air flow sensor and before the Turbo Never make the injection point after the Turbo or Intercooler because the pressure will not allow the best results with the HHO system Please be careful not to put the injection point close to the compressor air intake that will work on the brakes You will be using HHO gas not for saving fuel You will need to remove the air duct to ensure that you do not leave any residue from the drilling you are about to do Drill a 19 mm hole close to the intake manifold Clean out any drill shavings insert the high pressure fitting using goop glue or teflon tape and tighten Connect the high pressure hose Important Information When making the installation never make any type of changes in the dry cell Never open it loosen tighten the nuts or cut the screws You will damage the dry cell and it will not work properly after Changes made in the cell are not covered by the warranty HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com Sn m HHO Plus DC4000 Installation Manual Installation of the electrical components General configuration Please refer to the illustration below for typical wiring configuration for powering the system In the end
24. of the old data which is stored in its memory This old data no longer is credible as it pertains to conditions that existed before the modification The input data to the ECU should pertain to the post modification situation of the components and parts introduced while making the modification This means that you have to erase the old data from memory and new data pertaining to post modification should be logged into the ECU memory by mapping in new readings This is the reason why ECU resetting is essential for optimum performance after any modification has been carried out in your truck The moment you have carried out the modification you should purge out existing data in your ECU s memory You should then feed in fresh data pertaining to the conditions that have come into existence post HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com G HHO Plus DC4000 Installation Manual modification The ECU has to operate on the newly acquired data as this new data reflects the true conditions post modification Resetting the ECU when you choose to boost Octane with HHO gas becomes necessary because your ECU has a memory bank for octane This means that if you ve been using lower octane the response of ECU will correspond to lower octane with the booster matching lower octane performance The ECU response will continue to correspond to lower octane e
25. r system Check if the water cap is tight Main reason for problems Fix any that you find 3 Is the amperage on your generator to high Another thing that should be checked here is whether your unit is making HHO or steam Some of the early cell developers would run their units with so much amperage that the unit was producing more steam than anything else If your unit runs hot to the touch you must suspect that at least part of your output is steam One way to test for steam is to run your gas outlet over some ice If you get significant amounts of fog forming water droplets you know that at least part of your output is steam 4 Have you reset the ECU Old trucks do not require any special changes besides tuning the fuel injection pump But all other fuel injected engines will need to have it s electronics handled to get the gains of an HHO system installation Normally reseting the ECU will allow good fuel savings But you may need to handle also HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com G HHO Plus DC4000 Installation Manual the MAF MAP sensor enhancer and or the oxygen sensors upstream and downstream of the catalytic converter Some computers are able to learn and adapt to the conditions that exist in your engine Since you have made a major change by adding an HHO system and EFIEs you may need to reset the computer to eras
26. th that in mind and refill the tank when it is required Try to refill as often as it is possible for you in order to keep the generator running cool In our store we have a product that can help you to control better the water levels in the water tank and reduce the problems with the management of the A H 4 VA Jojo 000 00 000 system It is called the water level control switch _ Amperage variation in the system When operating the system the water molecule will be brocken into HHO gas to be used by the engine The water level in the tank will slowly go down but the electrolyte will continue in the system with an increase of the concentration and therefore amperage being drawn into the generator This means that when you start HHO Plus Alternative Energies Lta Travessa das Serras 33 Vieira de Leiria Portugal Tel 00351244697116 Email info hhhoplusgas com Qi HHO Plus DC4000 Installation Manual using the system with the tank full Max level you have 22 5A and after some time when the tank is at the lower point Min level you will have 27 5A If you put too much electrolyte there are a combination of heating factors at work and can cause a situation called Thermal Runaway where an increase in ambient temperature combined with excess electrolyte mix leads to overheating in the generator shortening the life of system When applying a direct current to the HHO genera
27. tor a high resistance will be present in the water electrolyte mixture High resistance generates heat causing the water to heat up As the temperature rises the resistance in the water goes down allowing more current to pass through the fuel cell By the end of the day the current will be higher than the value you started with at the beginning of the day One way to control this is using a PWM Pulse Width Modulator PWM PULSE WIDTH MODULATOR Pulse Width Modulation is a method of transmitting information on a series of pulses changing the frequency rather than a continuously varying analog signal It will allow you to control the amperage going into the generator in a very easy way This ability keeps the cell running at cool operating temperatures and prolongs the life of the cell while increasing the HHO output Efficiency HHO generators will run cooler than standard linear power amps requiring substantially less heat sink mass Amperage control the control of the amperage going into the generator will be very easy to control The ability to control the amperage keeps the cell running at cool operating temperatures and prolongs the life of the cell while increasing the HHO output e e ar dr P 5 F ad amp 4 T a ey My 9 q 4 a X z D nr E Dn 7 iie Ea wa C yoi gt Ga Electronic fuel injection Basic Information When adding a HHO gas to the engine of an old truck we will
28. ven though you have started using higher octane fuel This is because the ECU has not been reset for higher octane Thus even though higher octane is in actual use the data in ECU memory still corresponds to that of lower octane This mismatch affects performance as you are unable to derive the benefits of boosting the octane Therefore you should reset your ECU periodically after filling up full tank in order to ensure that ECU adjustments for its octane memory are made afresh corresponding to the octane actually in use Resetting the ECU Option 1 To reset the ECU you simply have to unplug the negative battery cable connection Theoretically it is best to leave it in this disconnected condition for as long as you can Practically leaving it disconnected overnight is more than enough After having left the cable disconnected for sufficient time you have to connect back the cable Start the car and keep it running so that it warms up This would not take more than 10 minutes at the most in summers Once you have done this you have accomplished the ECU resetting Shut off the engine You can now use your car whenever you feel like ECU resetting is over Resetting the ECU Option 2 You may also reset the ECU by simply unpluging both the negative and positive battery cable connections and after connect them both together Leave them connected around 40 minutes and then connect back the cables to the battery Start the car and keep it running so that
29. water molecule H20 into oxygen 02 and hydrogen H2 gases due to an electric current passing in the water An electrical power source is connected to two electrodes or two plates typically made from some inert metal such as stainless steel which are placed in the water In a properly designed cell hydrogen will appear at the cathode the negatively charged electrode where electrons enter the water and oxygen will appear at the anode the positively charged electrode The amount of hydrogen generated is twice the number of moles of oxygen and both are proportional to the total electrical charge Electrolysis of pure water requires excess energy in the form of potential to overcome various activation barriers Without the excess energy the electrolysis of pure water occurs very slowly or not at all This is in part due to the limited self ionization of water The efficacy of electrolysis is increased through the addition of an electrolyte such as a salt an acid or a base Electrolyte concentration The electrolyte should be added to the water the first time that you use the system and also when refilling but in lower quantities Amperage should be measured to ensure the right Water is getting a brown color operative conditions according to the table below after only a few hours working The electrolyte concentration to use in the HHO system depends on the type of electrolyte and the purity of the product The best You h
Download Pdf Manuals
Related Search
Related Contents
Piero Rossi Samsung VC-MCJ700 User Manual FTPU - Office 2010 - United Nations Economic Commission for Europe fonds joseph cardin mg 31-d188 - Bibliothèque et Archives Canada Mantis Mantenurako LED Studio 3300T LED Studio 3300D LED Studio 3305T LED Funk-Haus-Zentrale FHZ 1000 TEFAL GV8700E0 Instruction Manual Copyright © All rights reserved.