1. OPERATION Green light DRYING Blinking green light Genano 200 starts aircleaning automatically after 60 seconds drying delay PLEASE WASH Green and blinking yellow light TOP HATCH IS OPEN Blinking green and yellow light CLOSE DOWN HATCH Yellow and blinking red light WASH SEVERAL TIMES Both yellow and red light blinking FAILURE Continuous red light Turn unit off and restart it after 10 seconds If failure continues contact Genano service or sale organisation Sou een ae SA H E a PN G200 UM ENG ver 2 5 mod 28 2 07 Normal mode The green signal light is constantly illuminated when the unit is cleaning air see sidepanel lights All the hatches must be closed correctly to enable normal mode air cleaning Please note When the bottom hatch is closed it takes 60 seconds until Genano 200 starts air cleaning green light blinks This drying delay is a normal feature of Genano 200 Washing of collecting surfaces The device efficiently collects athmospherics particles on the collection surfaces Washing of the collection surfaces is made as easy as possible Just pour washing fluid to the opening on top of the unit This is recommended to do once a week The fluid is flushing through the surfaces and drops to the basin container Washing fluid is nature friendly Instructions to wash a unit Note Keep unit ON during the wash 1 Open down hatch and check that the basin is in its place if neces
2. follow instructions issued by local authorities for disposal See enclosed sheet for instructions A WARNING To reduce the risk of burns fire electric shock or injury to persons 1 Supervision is necessary when operated near children or the disabled 2 Use this air purifier device for its intended indoor use only as described in manual Do not use attachments not recommended by Genano Ltd Never use in an area with heavy wood dust or explosive chemicals ES WARNING Repairs and maintenance work must be carried out by qualified personnel only WARNING Due to its mode of operation the electronic air purifier may occasionally emit sparks Never use the air purifier in a place where flammable gases or liquids or large amounts of dust may combine with air to form an explosive mixture G200 UM ENG ver 2 9 mod 28 2 07 WARRANTY GENANO 200 MULTIFUNCTION ION MFI and NANOBIO are Registered Trademarks for Genano Limited Corporation products All Rights Reserved FULL 12 MONTHS WARRANTY Genano Ltd warrants each new MFI Air Cleaning Product Model against defects in materials or workmanship for a period of one year from the date of purchase and agrees to repair or replace any defective product without charge IMPORTANT This warranty does not cover damage resulting from accident misuse or abuse lack of reasonable care the affixing of any attachment not provided with the product or loss of parts or subjec
3. G200 UM ENG ver 2 mod 28 2 07 Genano 200 air purifier Operating instructions These instructions are for air purification units Genano 200 Genano 200 M Installation and operating instructions vestido MEA O Sidepamel lights Ati A Donat aa Er Diato Washing of collecting Surlaces ui a i caede Emptying Water basins rosi ds oda ies shed Technical specifications ee E AA Regular Clensing Ea EEE SS ESEE EEEE EO EEEE ES OPI A A T EE ETT structions A AA A A E AAA Ate LOMA PU A wedi TE E ee lade Wa E TE ES Disposal Ol uste ta lilas ti Technical Min il a IMPORTANT SAFETY INSTRUCTIONS do ap WARRANTY GENANG 200 ina aaa eta r aatasi ieoa G200 UM ENG ver 2 2 mod 28 2 07 Introduction Genano 200 airpurification unit removes even the smallest particles and fluids from indoor air Also gases are removed by active carbon plate Air purifier collects ultra fine particles UFP fine particles and other impurities to its collecting parts These impurities are flushed by pouring fluid once a week Two fan speeds can be selected by sidepanel switch Genano 200 intakes are equipped with prefilters metallic nets both side of the unit These nets are easy to clean by vacuum cleaner Fine particles that bypass prefilters are catched with electrical Multifunction Ion Air MFI technology Clean air is exhausted through the top vent of the unit Parts A BOTTOM HATCH amp BASIN basin for flush water B TOP HATCH C OPERATING SWITCHES A
4. ND SIGNAL LIGHTS a Main switch Power ON OFF Fan speed selector switch Position 1 80 m h Position 2 130 m h G200 UM ENG ver 2 3 mod 28 2 07 Installation and operating instructions Installation 1 Gently remove Genano 200 out of the crate and check the overall condition 2 Open the down hatch and check that the basin container is on its place close the hatch and lock it Important Always lock the hatches when this unit is located near children or pets 3 Make sure that the main switch is off position 0 before connecting the main cord to purifier Do not connect voltages other than the factory labeled requirement always use grounded power socket 4 Ensure that the top hatch is closed 5 Switch the main switch on position 1 Enjoy breathing A IMPORTANT To reduce the risk of electric shock this equipment has a grounding type plug that has a third grounding terminal s This plug is only allowed to connect into a grounding type power outlet If there is no grounded outlet installed contact qualified personnel to install the proper outlet Do not alter the plug in any way WARNING Due to its mode of operation the electronic air purifier may occasionally emit sparks Never use the air purifier in a place where flammable gases or liquids or large amounts of dust may combine with air to form an explosive mixture G200 UM ENG ver 2 mod 28 2 07 Sidepanel lights
5. ing administered 5 Do not use this device with a damaged or broken part as injury may occur 6 Always attach plug to device first then to outlet Be certain that plug is inserted firmly into device To disconnect turn device off then remove plug from outlet 7 To prevent possible damage to the cord do not wrap cord around the air cleaning device 8 Never put air cleaning device in direct hot sunlight or store in pouch at a temperature above 140 F 60 C EON
6. nce Genano 200 remainds see signal lights when its time to do wash Use only Genano washing fluid to prevent technical malfunctions G200 UM ENG ver 2 7 mod 28 2 07 Options Removable handles to help moving the unit Wall brackets Instructions Locating purifier Genano 200 takes impure air through intakes of lower sidewalls and pushs it out top of the unit This guarantees optimal movement of air Air purifier should be placed so that the flow of air through the purifier follows the direction of air circulation in the room Usually the best place is where incoming air flows in to a room In some rooms it is recommended to place purifier near the source of impurities e g processes or workstations and prevent impurities to spread around Anyway the efficiency of purification is always better near the purifier Caution The use of this unit is only allowed in normally ventilated rooms Do not cover air inlets or outlets or keep any objets on top of the purifier WARNING Due to its mode of operation the electronic air purifier may occasionally emit sparks Never use the air purifier in a place where flammable gases or liquids or large amounts of dust may combine with air to form an explosive mixture Disposal of flush water Genano fluid is nature friendly When Genano 200 is operated in ordinary home or office environment in most cases it is no restrictions to empty the dirty flush basin to the drain Some excepsio
7. ns needs special arrangements for example clensing of welding gases of air must be disposed correctly because of chromium Check the regulations of your local authorities G200 UM ENG ver 2 8 mod 28 2 07 Technical hints Genano 200 is equipped with High voltage measurement feature When filter inside is for example too wet this feature prevents start up until filter is dry Green light is blinking This extended drying period is a normal feature of the unit If the drying takes exceptionally long time and the unit does not start at all contact Genano service Please note that the washing of the collecting surfaces works best when unit is on vertical position This unit is only allowed to connect grounded power plug IMPORTANT SAFETY INSTRUCTIONS Read all instructions before using this appliance When using an electric air purifier device basic precautions should always be followed including the following A DANGER To reduce the risk of electric shock 1 Do not reach for a plug of an air purifier device that has fallen into water Disconnect power at main source then unplug immediately Do not use in close vicinity while bathing or in a shower Do not place in heavily moist atmosphere water or other liquid Do not place or store an air purifier device where it can fall or be pulled over Unplug this air purifier device before moving or transport to another location When discarding material used in this air purifier device
8. sary empty and clean basin 2 Close down basin if the red light is blinking basin is still open 3 Mix in the red can washing fluid with water Mixture 0 5 dcl fluid to 0 75 litres of water Read also instructions printed in the bottle Open top washing hatch Pour fluid rapidly into the hatch opening but prevent splashing Close the top hatch Sidepanel green light starts blinking The unit starts automatically after drying period During drying Genano 200 is not cleaning air ae G200 UM ENG ver 2 6 mod 28 2 07 Emptying water basin It is recommended to empty the water basin frequently Open the down hatch Ensure that there is no water flowing down to basin before you take basin out of the unit Washing fluid is nature friendly and can be disposed to the drain After emptying basin please clean it with soft towel Put the basin back to its place and lock the hatch Technical specifications Dimensions Height 125cm width 50cm depth 35cm Weight appr 30 kgs Consumption max 35 W Typical cleaning efficiency versus air volume Air volume 300nm 500nm 1000nm lum 80 m3 h speed 1 95 99 100 130 m3 h speed 2 75 85 95 Note The product of clean air is larger using greater volume but then cleaning efficiency goes lower Design by Harri Koskinen Regular Clensing In typical use it is recommended to do collector washing pouring fluid once a week This helps to maintain excellent air cleaning performa
9. ting the product to any but the specified voltage Use of unauthorized replacement parts will void this warranty GENANO CORPORATION WILL NOT PAY FOR WARRANTY SERVICE PERFORMED BY A NON AUTHORIZED REPAIR SERVICE AND WILL NOT REIMBURSE THE CONSUMER FOR DAMAGE RESULTING FROM WARRANTY SERVICE PERFORMED BY A NON AUTHORIZED REPAIR SERVICE NO RESPONSIBILITY IS ASSUMED FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES In order to obtain warranty service simply contact the nearest Authorized Genano Service Location It is suggested that for your protection you return shipments of products by insured transport insurance prepaid Damage occurring during shipment is not covered by this warranty NOTE No other warranty written or oral is authorized by Genano Ltd Finland This warranty gives you specific legal rights and you may also have other rights which vary from country to country Some countries do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion and limitations may not apply to you 1 Never operate this device if it has a damaged cord or plug if it has been dropped or damaged Return the device to an Authorized Genano Service Location for examination and repair Keep the cord away from heated surfaces Never drop or insert any object into any opening Do not plug in this air cleaning device outdoors or operate where aerosol spray products are being used or where oxygen is be

Download Pdf Manuals

image

Related Search

Related Contents

Colocación de la pila recargable  KI-G10S user manual updated  Riello UPS Dialog Dual DLD Series 650  JVC KD-MX2800R User's Manual  ガステーブル【スタンダードシリーズ】 ガスローレンジ 【スープレンジ】  Lightolier DPA2G24PP332 User's Manual  インフォメーション(P14~15)  FireplaceXtrordinair 4915 User's Manual  Skil 3410-02 Use and Care Manual  D - Viessmann  