Operating Instructions - VEGABAR 53 - 4...20mA/HART

image

Contents

1. 54 10 3 57 10 4 Industrial property rights 59 Contents jue pale VEDA Supplementary operating instructions manuals Information VEGABAR 53 is available in different versions and is supplied order specifically Depending on the selected version sup plementary operating instructions manuals come with the shipment The supplementary operating instructions are stated in paragraph Product description Operating instructions manuals for accessories and replacement parts Tip VEGA offers accessories and replacement parts for reliable use and operation of your VEGABAR 53 The corresponding operating instructions manuals are e Operating instructions manual External indicating and adjustment unit VEGADIS 61 e Operating instructions manual Oscillator VEGABAR series 50 and 60 VEGABAR 53 4 20 mA HART 700190 3 19 27513 EN 051004 VEBA gt VEGABAR 53 4 20 About this document 1 About this document 1 1 Function This operating instructions manual has all the information you need for quick setup and safe operation of VEGABAR 53 Please read this manual before you start setup 1 2 Target group This operating instructions manual is directed to trained personnel The contents of this manual should be made available
2. Caution No grease should be used when screwing the NPT cable gland or steel tube into the threaded insert Standard grease can contain additives affecting the connection between threaded insert and housing This will influence the stability of the connection and the tightness of the housing If screened cable is necessary connect the cable screen on both ends to ground potential In the sensor the screen must be connected directly to the internal ground terminal The ground terminal outside on the housing must be connected to the potential equalisation low impedance If potential equalisation currents are expected the connection on the evaluation side must be made via a ceramic capacitor e g 1 nF 1500 V The low frequency potential equalisation currents are thus suppressed but the protective effect against high frequency interference signals remains Take note of the corresponding installation regulations for Ex applications In particular make sure that no potential equal isation currents flow over the cable screen In case of grounding on both sides this can be achieved by the use of a capacitor or a separate potential equalisation 5 2 Connection procedure Proceed as follows 1 Unscrew the housing cover 2 Ifan indicating and adjustment module is installed remove it by turning it slightly to the left 3 Loosen compression nut of the cable entry 4 Remove approx 10 cm 4 in of the cable mantle s
3. M20x1 5 M20x1 5 Ye NPT 2 Fig 22 Housing versions in protection IP 66 IP 68 1 bar with integrated PLICSCOM the housing height increases by 9 0 35 in 1 Stainless steel housing 2 Aluminium double chamber housing 3 Aluminium housing 54 VEGABAR 58 4 20 mA HART 700190 3 1946 27513 EN 051004 EN Supplement VEGABAR 53 threaded fitting 1 3 1 GN Fig 23 VEGABAR 53 GV G 1 2A manometer connection GF G 1 2A flush GC G 1A flush GE G 1A flush up to 150 C acc to EHEDG GN 1 2 NPT VEGABAR 53 4 20 55 VEGABAR 53 hygienic fitting 2 33 64 CA Fig 24 VEGABAR 53 CA Tri Clamp 2 LA hygienic fitting with compression nut 56 VEGABAR 53 4 20 700190 3 1946 27513 EN 051004 EN Supplement 10 3 Certificate CE declaration of conformity Konformitatserklarung Declaration of comormity Declaration de comormite MEC Arm Beer 113 T3787 Eph mirc gea Perec Saws doe Zu mia Ful cle mos es rmumpormac ek VEGABAR 52 VECUABAFI 54 VEGABAR 61 VEGAB AR VEOJBAR 65 VEOABAR VEGAEAR uid dam mch
4. 35 36 Setup with the indicating and adjustment module PLICSCOM Service Basic adjustment Display Diagnostics gt Service Info Simulation Reset 4 3 Current output Start simulation Reset Output mode 4 20 mA Failure mode lt 3 6mA Min current 3 8mA HART mode PIN Standard Copy sensor data Enable Address 0 Info Basic adjustment Display Diagnostics Service gt Info Sensor type Date of manufacture 5 2 Date of last change using P6 3 VEGABAR 5x 26 Aug 2005 Software version Serial number 3 22 26 Aug 2005 12345678 VEBA Language 4 4 Deutsch Application Process pressure Sensor details Display now VEGABAR 53 4 20 mA HART 700190 3 1946 27513 EN 051004 VEBA VEGABAR 53 4 20 mA HART Setup with the indicating and adjustment module PLICSCOM 6 6 Saving the parameter adjustment data is recommended noting the adjusted data e g in this operating instructions manual and archive them afterwards They are hence available for multiple use or service purposes If VEGABAR 53 is equipped with an indicating and adjustment module PLICSCOM the most important data can be read out of the sensor into PLICSCOM The procedure is described in the operating instructions manual Indicating and adju
5. Fig 12 Electronics compartment double chamber housing 1 Plug connector for VEGACONNECT interface 2 Internal connection cable to the connection compartment 3 Terminals for VEGADIS 61 Fig 13 Connection compartment double chamber housing Exd 1 Spring loaded terminals for power supply and cable screen 2 Ground terminal for connection of the cable screen VEGABAR 58 4 20 mA HART 700190 3 1946 27513 EN 051004 VEBA Wiring plan Wire assignment connection cable Switch on phase VEGABAR 53 4 20 mA HART Connecting to power supply Fig 14 Wiring plan double chamber housing Exd 1 Power supply Signal output 5 6 Wiring plans version IP 66 IP 68 1 bar This version is only available for instruments with absolute pressure measuring ranges Fig 15 Wire assignment connection cable 1 br and bl for power supply or to the processing system 2 Screen 5 7 Switch on phase After VEGABAR 53 is connected to power supply the instrument carries out a self test for approx 30 seconds The following steps are carried out e Internal check of the electronics e Indication of the instrument type the firmware version as well as the sensor TAGs sensor name e Output signal jumps briefly approx 10 seconds to the set fault current Then the actual measured value is displayed
6. 10 70 14 4158 F Version for oxygen applications without with PLICSCOM 40 60 C 40 140 F Process conditions The specifications of the pressure stage are used as an overview The specifications on the type plate are applicable Pressure stage process fitting Thread see type label Tri Clamp 1 1 2 316L PN 16 Tri Clamp 2 316L PN 10 Hygienic fitting LA 316L PN 40 Product temperature depending on seal and O ring Viton 20 105 C 4 221 F EPDM 40 105 C 40 221 F 25 105 13 221 F Product temperature with connection G1A front flush acc to EHEDG Viton EPDM 10 150 C 14 302 F Product temperature hygienic fittings Tri Clamp 20 150 C 4 302 hygienic fitting LA LD 20 120 C 4 248 F Vibration resistance mechanical vibrations with 4 g and 5 100 Hz 9 Acc to IEC 60770 1 relating to the nominal range up to 60 C 140 Version for oxygen applications to 60 C 140 Tested acc to the regulations of German Lloyd GL directive 2 VEGABAR 53 4 20 49 Supplement Electromechanical data version IP 66 IP 67 Cable entry plug 17 VEBA Single chamber housing e 1xcable entry M20x1 5 cable 5 9 1x blind stopper M20x1 5 or e 1 closing cap NPT 1x blind stoppe
7. USB 62 36G X In hazardous areas you should take note of the appropriate regulations conformity and type approval certificates of the sensors and power supply units Power supply and current signal are transmitted via the same two wire connection cable The power supply range can differ depending on the instrument version The exact range is stated in the Technical data in the Supplement Provide a reliable separation between the supply circuit and the mains circuits acc to DIN VDE 0106 part 101 The VEGA power supply units VEGATRENN 149AEx VEGASTAB 690 VEGADIS 371 as well as all VEGAMETs meet this require ment Bear in mind the following factors regarding supply voltage e thereduction of the output voltage of the power supply unit under nominal load with a sensor current of 20 5 mA or 22 in case of fault signal e the influence of additional instruments in the circuit see load values in Technical data VEGABAR 53 is connected with standard two wire cable without screen An outer cable diameter of 5 9 mm ensures the seal effect of the cable entry If strong electromagnetic interference is expected we recommend the use of screened cable On VEGABAR 53 with cable gland 12 NPT and plastic housing a metal 1 2 threaded insert is moulded in the plastic housing Connecting to power supply A Cable screening and ground ing Select connection cable for Ex applica tions 16 VEBA
8. also the density has to be entered Proceed as follows 1 Push the OK button in the measured value display the menu overview is displayed Confirm the menu Basic adjustment with OK the menu item Units of measurement will be displayed Activate the selection with OK and select the requested unit with gt in the example m Confirm with OK the submenu Density unit appears Units of measurement Density unit gt kg dm pcf Select the requested unit e g kg dm with gt and confirm with OK the submenu Density appears Units of measurement Density 0001 000 kg dm 6 Enter the requested density value with gt and confirm with OK and move to position correction with gt The adjustment unit is now changed from bar to m VEGABAR 58 4 20 mA HART 700190 3 1946 27513 EN 051004 VEBA Carry out position correction Carrying out min adjustment Carrying out max adjustment VEGABAR 53 4 20 mA HART Setup with the indicating and adjustment module PLICSCOM Proceed as follows 1 Edit the offset value in the menu item Position correction with OK Position correction Offset 0000 0 mbar 53 0 mbar 2 Set the requested offset value e g the actual measured value with reciprocal sign with gt and 3 Confirm with OK and move to min zero adjustment with 7 Proceed
9. 200 kPa bar O kPa 0 1 6 bar 0 160 kPa 10 bar 1 000 kPa bar O kPa 0 40 bar O 4 MPa 80 bar 8 MPa bar O kPa 0 100 bar O 10 MPa 200 bar 20 MPa bar O kPa 0 250 bar O 25 MPa 500 bar 50 MPa kPa 0 600 bar 0 60 MPa 1 200 bar 120 MPa bar O kPa 1 3 bar 100 300 kPa 17 bar 1 700 kPa 1 0 bar 100 kPa 1 5 bar 100 500 kPa 35 bar 3500 kPa 1 0 bar 100 kPa 1 15 bar 100 1 5 MPa 80 bar 8 MPa 1 0 bar 100 kPa Absolute pressure 0 0 4 bar O 0 kPa 2 bar 20000 kPa 0 1 6 bar 0O 160 kPa 10 bar 1 000 kPa 0 6 0 bar 0 600 kPa 35 bar 3500 kPa 0 16 0 bar O 16 MPa 80 bar 8 MPa VEGABAR 53 4 20 47 Supplement VEBA Reference conditions and influencing variables similar to DIN EN 60770 1 Reference conditions acc to DIN EN 61298 1 Temperature Relative humidity Atmospheric pressure Determination of characteristics Characteristic Calibration position Influence of the installation position Deviation in characteristics Deviation in characteristics Turn down 1 1 Turn down up to 1 5 Turn down bis 1 20 18 30 64 4 86 F 45 75 860 1060 mbar 86 106 kPa 12 5 15 4 psi limit point adjustment acc to DIN 16086 Linear upright diaphragm points downward depending on the isolating diaphragm version 0 15 96 0 15 96 0 3 96 Influenc
10. VEGABAR 53 Gauge pressure or gauge pressure depending on the measuring range piezore sistive with internal transmission liquid or strain gauge DMS dry 2 bus 316Ti 1 4571 316Ti 1 4571 Elgiloy 2 4711 Viton EPDM NBR synthetic 0119 Halocarbon oilo plastic PBT Polyester Alu die casting pow der coated 316L 1 4435 NBR stainless steel housing silicone Alu plastic housing Polycarbonate UL746 C listed 316Ti 316L 1 4571 1 4435 0 8 kg 1 8 Ibs meas ranges from 25 bar dry meas cell 10 Generally for oxygen applications not with vacuum meas ranges not with absolute meas range lt 1 bafaps 46 VEGABAR 53 4 20 mA HART 700190 3 19 27513 EN 051004 EN Supplement Output variable Output signal 4 20 Resolution 1 6 pA Fault signal current output unchanged 20 5 mA 22 mA 3 6 mA adjustable Current limitation 22 mA Load see load diagram in Power supply Integration time 63 of the input 999 s adjustable variable Response time 150 ms ti O s O 100 Fulfilled NAMUR recommendation NE 43 Input variable Adjustment range of the adjustment zero Min 5 95 96 of the nominal measuring range span Max 5 105 of the nominal measuring range Recommended max turn down 1 30 no limitation Nominal range Overload resistance Vacuum resistance Gauge pressure 0 0 4 bar O 40 kPa 2 bar
11. and PDM are available as DD or EDD The instrument descriptions are already implemented in the current versions of AMS and PDM For older versions of AMS and PDM a free of charge download is available via Internet Move via www vega com and Downloads to the item Software 7 4 Saving the parameter adjustment data It is recommended to document or save the parameter adjustment data They are hence available for multiple use or service purposes The VEGA DTM Collection and PACTware in the licensed professional version offer the suitable tools for a systematic project documentation and recording VEGABAR 53 4 20 700190 3 1946 27513 EN 051004 VEBA Causes of malfunction Fault rectification 24 hour service hotline Checking the 4 20 mA sig nal VEGABAR 53 4 20 mA HART Maintenance and fault rectification 8 Maintenance and fault rectification 8 1 Maintenance When used as directed in normal operation VEGABAR 53 is completely maintenance free 8 2 Fault rectification VEGABAR 53 offers maximum reliability Nevertheless faults can occur during operation These may be caused by the following e g Sensor Process Power supply Signal processing The first measures to be taken are to check the output signal as well as evaluate failure messages via the indicating and adjustment module PLICSCOM The procedure is described in the followin
12. and the corresponding current is transmitted to the cable 5 values correspond to the actual level as well as to the settings already carried out e g default setting 23 Setup with the indicating and adjustment module PLICSCOM W a Function Configuration Insert remove PLICSCOM 24 6 Setup with the indicating and adjustment module PLICSCOM 6 1 Short description The indicating and adjustment module PLICSCOM is used for measured value display adjustment and diagnosis It can be mounted in the following housing versions and instruments e All sensors of the plics instrument family in the single as well as in the double chamber housing optionally in the electronics or connection compartment e External indicating and adjustment unit VEGADIS 61 Note You will find detailed information on the adjustment in the operating instructions manual of the indicating and adjustment module PLICSCOM 6 2 Installing the indicating and adjustment module PLICSCOM PLICSCOM can be inserted or removed at any time It is not necessary to interrupt the power supply To mount proceed as follows 1 Unscrew the housing cover 2 Place PLICSCOM in the desired position on the electronics you can choose any one of four different positions each displaced by 90 3 Press PLICSCOM lightly onto the electronics and turn it to the right until it snaps in 4 Screw housing cover with inspection wind
13. as follows 1 Edit in the menu item Min adjustment the value with OK Min adjustment 4000 0 96 0000 0 mbar 0000 0 mbar 2 Set the requested value with and gt 3 Edit the requested mbar value with 4 Set the requested mbar value with and gt 5 Confirm with and move to max adjustment with gt The min adjustment is finished Information To adjust with a filling you simply enter the indicated actual measured value If the adjustment ranges are exceeded the message is displayed Outside parameter limits The editing procedure can be interrupted with ESC or the displayed limit value can be accepted with Proceed as follows 1 Edit the value in the menu item Max adjustment with OK 33 Setup with the indicating and adjustment module PLICSCOM WI a 34 mio Max adjustment 100 0 1000 0 mbar 0000 0 mbar Information The displayed pressure for 100 corresponds to the nominal measuring range of the sensor in the above example 1 0 bar 1000 mbar Set the requested value with gt and OK Edit the requested mbar value with OK 2 3 4 Set the requested mbar value with and gt 5 Confirm with OK and move to the menu overview with ESC The max adjustment is finished Information To adjust with a filling you simply enter the indicated actual measured
14. dass bri nare 2a ried rdi cer i2 gaadan Hamas 2 cp a clin ig ir corksrwg an fes uasdacda wage sans vd ie zeros ci Soe Rp DIJGTGME HEN TIE TOH Himen 124 DATH ONE DODA aie ech Arnkarg 1010 1 dee Pete m 1 boa Eu rx EM E WII Joma Fiebre Erib pr Fig 25 CE declaration of conformity VEGABAR 53 4 20 57 Supplement VEGA Manufacturer declaration Ere Fees 115 P mb eos H i ee LAT ir acts ERE i T gro 5 71 een ELM rp p B inf v AA i Bre o t m eee Em mam n erm er n at cni dala e p datum arr ix mam Doer Ta mm GEB ee arem 0 ed ee ee E isig Wri Pe LE 1 fcri nj onm FE LaL ELE icq mia i len mms volle Las sS NIU br emi mad br dated geet operand nant a ann grater dup Orig cn Fa een Pu precem gr ctm oso metr coin LETT Bred eed Sm ed cae eed eee Bog ee e Pa ruri bu iw cone rui be eed it ira ee m coa we ees rear fea acia mecha PLC EL TIS nens
15. pressure or vacuum Measured products are gases vapours and liquids up to 600 bar With flush version also viscous liquids The process pressure acts via the stainless steel diaphragm to the sensor element A resistance change is caused which is converted into a respective output signal and outputted as measured value Two wire electronics 4 20 mA HART for power supply and measured value transmission on the same cable The power supply range can differ depending on the instru ment version The exact range is stated in the Technical data in the Supplement 3 3 Adjustment VEGABAR 53 can be adjusted with four different adjustment media e the indicating and adjustment module PLICSCOM e with the suitable VEGA DTM in conjunction with an adjustment software acc to FDT DTM standard e g PACTware and PC e with manufacturer specific adjustment programs AMS or PDM e handheld The entered parameters are generally saved VEGABAR 53 optionally also in PLICSCOM or in PACTware M 3 4 Storage and transport Your instrument was protected by packaging during transport Its capacity to handle normal loads during transport is assured by a test acc to DIN 55439 The packaging of standard instruments consists of environ ment friendly recyclable cardboard For special versions PE foam or PE foil is also used Dispose of the packaging material via specialised recycling companies 1 For meas ranges up to
16. than 3 6 mA electronics module or measuring cell defective gt Exchange instrument or return it for repair Upcoming failure message via PLICSCOM gt see below In Ex applications the regulations for the wiring of intrinsically safe circuits must be observed E013 no measured value available9 gt return instrument for repair E017 adjustment span too small gt repeat with modified values E036 no operable sensor software gt carry out a software update or return instrument for repair Fault message can come up if the pressure is higher than the nominal range VEGABAR 53 4 20 mA HART 700190 3 19 27513 EN 051004 V mum VEGABAR 53 4 20 Maintenance and fault rectification E041 e Hardware error gt Exchange instrument or return it for repair 8 3 Exchanging the electronics The electronics of VEGABAR 53 consists of the measuring cell electronics and the processing electronics The measuring cell electronics in the process fitting is not accessible to the user The processing electronics is in the form of a module in the housing If this electronics is defective it can be exchanged by the user The electronics modules differ only in their signal output and are Suitable for all VEGABAR series 50 and 60 sensors The following types are available e BR E 60H 4 20 mA HART e BR E 60P Profibus PA e BR E 60F F
17. value If the adjustment ranges are exceeded the message is displayed Outside parameter limits The editing procedure can be interrupted with ESC or the displayed limit value can be accepted with OK The setup of VEGABAR 53 is finished All other menu items are described in the separate operating instructions manual of the indicating and adjustment module PLICSCOM VEGABAR 58 4 20 mA HART 700190 3 1946 27513 EN 051004 W 51 A Setup with the indicating and adjustment module PLICSCOM 6 5 Menu schematic Basic adjustment gt Basic adjustment Display Diagnostics Service Info Zero 1 3 000 0 Position correction 1 2 Ma 0000 mbar 53 mbar Units of measurement 1 1 1 4 100 00 1000 mbar 53 mbar bar 000 mbar 53 mbar Damping 1 5 Linearization curve Sensor TAG Linear Sensor Display Basic adjustment gt Display Diagnostics Service Info Displayed value 2 1 Displayed value 2 1 Display units 2 2 Scaling 2 3 Pressure scaled Volume 0 2 0 0 100 1000 0 Diagnostics Basic adjustment Display gt Diagnostics Service Info Peak values Sensor status Tmin 12 5 C Tmax 85 5 C p min 0 58 bar p max 16 765 bar Trend recording 3 4 OK VEGABAR 53 4 20
18. 16 bar piezoresistive sensor element with internal transmission liquid for meas ranges from 25 bar strain gauge DMS sensor element on the rear of the stainless steel diaphragm dry VEGABAR 53 4 20 mA HART 700190 3 19 27513 EN 051004 W 51 A Product description Instruments for oxygen applications are welded in PE foil and provided with a label Oxygen Use no Oil Remove this foil just before mounting the instrument Storage and transport tem e Storage and transport temperature see Supplement perature Technical data Ambient conditions e Relative humidity 20 85 Mounting Wetted materials Diaphragm protec tion Installation location Moisture 12 VEBA 4 Mounting 4 1 General instructions Check if the wetted materials such as seal process fitting etc are suitable for the existing process conditions such as product temperature etc Caution After removing the diaphragm protection the diaphragm must not be impressed Select an installation position you can easily reach for mounting and connecting as well as later retrofitting of an indicating and adjustment module The housing can be rotated by 330 without the use of any tools You can also install the indicating and adjustment module in four different positions each displaced by 90 Use the recommended cable see chapter Connecting to power supply and tight
19. Confirm the menu Basic adjustment with OK the menu item Units of measurement will be displayed Units of measurement bar 3 Activate the selection with OK and select the requested unit with gt in the example mbar 4 Confirm with OK and move to position correction with gt The adjustment unit is now changed from bar to mbar Proceed as follows 1 Edit the offset value in the menu item Position correction with 9 Selection options mbar bar psi Pa kPa MPa inHg mmHg inH2O mmH O VEGABAR 53 4 20 mA HART 700190 3 19 27513 EN 051004 VEBA Carry out zero adjustment Carry out span adjustment VEGABAR 53 4 20 mA HART Setup with the indicating and adjustment module PLICSCOM Position correction Offset 0000 0 mbar 53 0 mbar 2 Set the requested offset value e g the actual measured value with reciprocal sign with gt and 3 Confirm with OK and move to min zero adjustment with gt Proceed as follows 1 Edit the mbar value in the menu item zero with OK Zero adjustment 000 0 AP 0000 0 mbar 0000 0 mbar 2 Set the requested mbar value with and gt 3 Confirm with OK and move to span adjustment with gt The zero adjustment is finished Information The zero adjustment shifts the value of the span adjustment The span i e the difference between these va
20. Operating Instructions VEGABAR 53 4 20 mA HART Contents VEGA Contents 1 About this document 1 1 FUNCUON caus eee dee ws 5 12 Target 5 1 3 Symbolism 5 2 For your safety 2 1 Authorised 6 2 2 6 2 3 Warning about 6 2 4 General safety instructions 6 2 5 CEconformity 0 000 eee 6 2 6 Compatibility acc to NAMUR NE 53 7 2 7 Safety information for Ex areas 28 Safety instructions for oxygen applications 7 2 9 Environmental instructions 8 3 Product description 3 1 9 3 2 Principle of 10 39 s uc iaces ic eee do Eod 10 3 4 Storage and transport 10 4 Mounting 4 1 General 12 4 2 Mounting 13 4 3 Mounting 13 5 Connecting to power supply 5 1 Preparing the 15 5 2 Connection 16 5 3 Wiring plans single chamber housing 17 5 4 Wiring plans double chamber housing 19 5 5 Wiring plans double ch
21. amber housing Exd 21 5 6 Wiring plans version IP 66 IP 68 1 bar 23 5 7 23 6 Setup with the indicating and adjustment module PLICSCOM 6 1 Short 24 6 2 Installing the indicating and adjustment module PHOGSCONM u sia oe eke eR 24 6 3 Adjustment system 26 64 27 2 VEGABAR 53 4 20 700190 3 19 27513 EN 051004 VEBA VEGABAR 53 4 20 mA HART 10 Contents 65 34 6 6 Saving the parameter adjustment data 37 Setup with PACTware and other adjustment programs 7 1 Connecting the PC 38 7 2 Parameter adjustment with PACTware 39 7 3 Parameter adjustment with AMS and PDM 40 7 4 Saving the parameter adjustment data 40 Maintenance and fault rectification 8 1 41 8 2 41 8 3 Exchanging the electronics 43 8 4 43 Dismounting 9 1 Dismounting procedure 45 9 2 45 Supplement 10 1 Technical 46 10 2
22. and guidelines The user must take note of the safety instructions in this operating instructions manual the country specific installation standards e g the VDE regulations in Germany as well as all prevailing safety regulations and accident prevention rules 2 5 CE conformity VEGABAR 53 is in CE conformity with 89 336 EWG fulfils the NAMUR recommendation NE 21 and is in CE conformity with LVD 73 23 EWG Conformity has been judged acc to the following standards e EMC Emission EN 61326 2004 class B Susceptibility EN 61326 2004 incl supplement A e LVD EN 61010 1 2001 Furthermore VEGABAR 53 is subject to the pressure device directive 97 23 EG e Instruments with max permissible pressures exceeding 200 bar need the CE marking VEGABAR 53 4 20 mA HART 700190 3 LSZ 27513 EN 051004 VEBA VEGABAR 53 4 20 mA HART For your safety e Instruments with max permissible pressures less than 200 bar do not need a CE marking 2 6 Compatibility acc to NAMUR NE 53 VEGABAR 53 meets NAMUR recommendation NE 53 VEGA instruments are generally upward and downward compatible e sensor software for DTM VEGABAR 53 HART PA or FF e DTM VEGABAR 53 for adjustment software PACTware e adjustment module PLICSCOM for sensor software The parameter adjustment of the basic sensor functions is independent of the software version The range of available functions dep
23. compartment double chamber housing 1 2 3 Plug connector for VEGACONNECT I7C interface Internal connection cable to the connection compartment Terminals for VEGADIS 61 Fig 9 Connection compartment double chamber housing 1 2 3 Plug connector for VEGACONNECT interface Ground terminal for connection of the cable screen Spring loaded terminals for power supply VEGABAR 53 4 20 mA HART 700190 3 1946 27513 EN 051004 W A Connecting to power supply Wiring plan ee a g AU N N 2 HH Rud LB Fig 10 Wiring plan double chamber housing 1 Power supply Signal output 5 5 Wiring plans double chamber housing Exd Housing overview Fig 11 Double chamber housing Housing cover connection compartment Blind stopper plug M12x1 for VEGADIS 61 option Housing cover electronics compartment Filter element for pressure compensation or blind stopper with version IP 66 IP 68 1 bar Cable entry or plug 4 Version IP 66 IP 68 1 bar not with four wire instruments VEGABAR 53 4 20 21 Connecting to power supply Electronics compartment Connection compartment 22 VEBA 7 QU w
24. cv ity ey ara zen d urbs ee TUR ee ay a E nor imer Ia cores CMS ZB n ed ba A mA a ey eg LLL DLL Bej ul t Ia Gores ee REL 14 WC ah dem CH Fig 26 Manufacturer declaration 58 VEGABAR 53 4 20 V00LSO N3 ISZc 27513 EN 051004 VEDA Supplement 10 4 Industrial property rights VEGABAR 53 4 Furmer imnformalbien ae Wipe com Dek a DBA Fumar niormmabos aue ai e oe hoeudung Lint de padais VECA soni par sni droi du Sociale riballetdusBae Par pim Sito on prenta ma cere wis ipa ee crm Mara rra ontario fete la pagia seal beeen com BETA MARLIEN Ee HD WAHT LTT yi ery Tisi eir roo Dind OTT DAA 0 Com VEGA Ayi RORE ea ee iE EAR ae VH eh pc mna ng i s 20 mA HART 59 VEBA VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone 49 7836 50 0 Fax 49 7836 50 201 E mail info de vega com www vega com All statements concerning scope
25. dure Warning Before dismounting be aware of dangerous process con ditions such as e g pressure in the vessel high temperatures corrosive or toxic products etc Take note of chapters Mounting and Connecting to power supply and carry out the listed steps in reverse order 9 2 Disposal VEGABAR 53 consists of materials which can be recycled by specialised recycling companies We have purposely de signed the electronic modules to be easily separable Mark the instrument as scrap and dispose of it according to national government regulations e g in Germany acc to electronic scrap ordinance Materials see Technical data If you cannot dispose of the instrument properly please contact us about disposal methods or return 45 Supplement 10 Supplement 10 1 Technical data General data Manufacturer Type name Pressure Measuring principle Communication interface Materials and weights Materials wetted parts Process fitting Diaphragm standard Diaphragm from measuring range 25 bar with not flush version Seal ring O ring Materials non wetted parts Internal transmission liquid Housing Seal ring between housing and housing cover Inspection window in housing cover for PLICSCOM Ground terminal Weight 9 For meas ranges up to 16 bar FDA listed for food processing industry For VEBA VEGA Grieshaber KG D 77761 Schiltach
26. e of the product or ambient temperature The following specifications are valid for values within the compensated temperature range i e O 80 C 176 F reference temperature 20 C 68 F Average temperature coefficient of the zero signal Standard Meas ranges O 0 1 and 0 0 16 bar Average temperature coefficient of the span 0 2 10 lt 0 4 10 lt 0 2 10 The following specifications are valid for values not within the compensated temperature range Average temperature coefficient of the zero signal Standard Meas ranges 0 0 1 and 0 16 bar Average temperature coefficient of the span typ 0 2 96 10 typ 0 4 96 10 typ 0 2 96 10 10 Relating to the nominal range incl hysteresis and repeatability determined acc to the limit point method 12 Relating to the adjusted span incl hysteresis and reproducibility 48 VEGABAR 53 4 20 mA HART 700190 3 19 27513 EN 051004 EN Supplement Long term stability similar to DIN 16086 DINV 19259 1 and IEC 60770 1 Long term drift of the zero signal s 0 1 year Ambient storage and transport temperature Standard versions without PLICSCOM 40 80 40 176 F with PLICSCOM 20 70 4 158 F Connection G1A front flush acc to EHEDG without PLICSCOM 10 80 14 176 F with PLICSCOM
27. en the cable gland You can give your VEGABAR 53 additional protection against moisture penetration by leading the connection cable down ward in front of the cable entry Rain and condensation water can thus drain off This applies mainly to mounting outdoors in areas where moisture is expected e g by cleaning processes or on cooled or heated vessels Fig 2 Measures against moisture penetration VEGABAR 53 4 20 mA HART 700190 3 1946 27513 EN 051004 VEBA Oxygen applications Installation location Welding the socket Sealing Screwing in VEGABAR 53 4 20 Mounting Danger Instruments for oxygen applications should be unpacked just before mounting After removing the protective cover of the process fitting the label O will be visible on the process fitting Penetration of oil grease and dirt should be avoided Danger of explosion 4 2 Mounting information VEGABAR 53 functions in any installation position It is mounted acc to the same regulations like a manometer DIN EN 839 2 Information We recommend using lock fittings measuring instrument holders and siphons from the line of VEGA accessories 4 3 Mounting procedure To mount VEGABAR 53 a welded socket is necessary Use components from the line of VEGA mounting accessories e Welded socket G1B front flush max 150 C 302 F article no 2 27868 e Welded socket G1B fro
28. ends on the respective software version of the individual components The software version of VEGABAR 53 can be determined as follows e via PACTware e on the type label of the electronics e via the adjustment module PLICSCOM On our website www vega com you will find all software histories Make use of this convenience and get registered for update information via e mail 2 Safety information for Ex areas Please note the Ex specific safety information for installation and operation in Ex areas These safety instructions are part of the operating instructions manual and come with the Ex approved instruments 2 8 Safety instructions for oxygen applications For instruments in oxygen applications the special instructions in chapters Storage and transport as well as Mounting must be noted Furthermore the valid regulations implementation instructions and memorandums of the BG professional assoc must be noted For your safety VEBA 2 9 Environmental instructions Protection of the environment is one of our most important duties That is why we have introduced an environment management system with the goal of continuously improving company environmental protection The environment man agement system is certified acc to DIN EN ISO 14001 Please help us fulfil this obligation by observing the environ mental instructions in this manual e Chapter Storage and transport e Chapter Di
29. essure when being submerged e g in water This can falsify the meas ured value 52 VEGABAR 53 4 20 mA HART 700190 3 19 27513 EN 051004 W EN Supplement Available approvals or approvals applied for 929 ATEX ia ATEX II 1G 1 2G 2G EEx ia T6 ATEX ia a d ATEX Il 1 2G 2G EEx d ia T6 ATEX D ATEX II 1 20 2D IP6X T IEC IEC Ex ia IIC T6 FM FM CI I III Div 1 IS Ship approvals GL LRS ABS CCS RINA DNV Others WHG 19 Deviating data with Ex applications see separate safety instructions 20 Depending on order specification VEGABAR 53 4 20 53 Supplement 10 2 Dimensions Housing in protection IP 66 IP 67 69mm 87mm 3 27164 2 23 39 77mm 84mm 116mm 4 9 46 5 46 84mm 3 5 16 69mm 2 23 32 77mm M20x1 5 Ye NPT 20 1 5 20 1 5 Yo NPT 9 wr 8 Fig 21 Housing versions protection IP 66 IP 67 with integrated PLICSCOM the housing height increases by 9 mm 0 35 in Plastic housing Stainless steel housing Aluminium double chamber housing Aluminium housing Housing in protection 66 IP 68 1 bar 103mm E 105mm 4 9 g4 4 1 16 g 84mm 150mm 5 29 39 3 She 84mm 3 5 6
30. g Further comprehensive diagnostics options can be accessed via a laptop with the software PACTware and the suitable DTM In many cases the causes can be determined in this way and faults can be rectified Should these measures not be successful please call in urgent cases the VEGA service hotline under the phone number 49 1805 858550 The hotline is available to you 7 days a week round the clock Since we offer this service world wide the support is only available in the English language The service is free of charge only the standard telephone costs will be charged Connect a hand held multimeter with a suitable measuring range acc to the wiring plan 20 mA signal not stable level fluctuations gt set integration time PLICSCOM or PACTware no atmospheric pressure compensation gt check the pressure compensation in the housing and clean the filter element if necessary 41 Maintenance and fault rectification Error messages via PLICSCOM 42 VEBA 4 20 mA signal missing incorrect connection to power supply gt Check connection acc to chapter Connection proce dure and correct if necessary acc to chapter Wiring plans no power supply gt check cables for line break repair if necessary supply voltage too low or load resistance too high gt check and adapt if necessary 2 Current signal greater than 22 mA or less
31. is triggered Any values not confirmed with will not be saved VEGABAR 58 4 20 mA HART 700190 3 19 27513 EN 051004 VEBA Address setting HART Multi drop Process pressure or level measurement Optional settings Parameter adjust ment Process pres sure measurement VEGABAR 53 4 20 mA HART Setup with the indicating and adjustment module PLICSCOM 6 4 Setup procedure In HART Multidrop mode several sensors on one input the address must be set before continuing with the parameter adjustment You will find a detailed description in the operating instructions manual of PLICSCOM or in the online help of PACTware or DTM HART mode Standard Address 0 VEGABAR 53 can be used for process pressure as well as for level measurement Default setting is process pressure measurement The mode can be changed in the adjustment menu Depending on your application only the respective subchapter Process pressure measurement or Level measurement will apply There you will find the individual adjustment steps Additional adjustment and diagnosis options such as e g scaling simulation or trend curve presentation are shown in the following menu schematic You will find a detailed description of these menu items in the operating instructions manual of the indicating and adjustment module PLICSCOM Process pressure measurement Set up VEGABAR 53 in the following seq
32. lues however remains unchanged Information To adjust with pressure you simply enter the indicated actual measured value If the adjustment ranges are exceeded the message is displayed Outside parameter limits The editing procedure can be interrupted with ESC or the displayed limit value can be accepted with Proceed as follows 1 Edit the mbar value in the menu item span with OK Span adjustment 100 0 1000 0 mbar 0000 0 mbar 29 Setup with the indicating and adjustment module PLICSCOM W a Parameter adjust ment Level meas urement 30 i Hio Pale Information The displayed pressure for 100 corresponds e g to the nominal range of the sensor in the above example 1 0 bar 1000 mbar 2 Set the requested mbar value with gt and OK 3 Confirm with OK and move to the menu overview with ESC The span adjustment is finished Information To adjust with pressure you simply enter the indicated actual measured value If the adjustment ranges are exceeded the message is displayed Outside parameter limits The editing procedure can be interrupted with ESC or the displayed limit value can be accepted with OK The setup of VEGABAR 53 for process pressure measure ment is finished All other menu items are described in the separate operating instructions manual of the indicating and adjustment module PLICSCOM Level
33. measurement Set up VEGABAR 53 in the following sequence Select application Level measurement 2 Select adjustment unit density unit 3 Carry out position correction 4 Carrying out min adjustment 5 Carrying out max adjustment In the menu item Application you switch over from Process pressure to Level measurement In the menu item Units of measurement you select the physical unit in which the adjustment should be carried out e g mbar bar psi The position correction compensates the influence of the mounting position or static pressure on the measurement It does not influence the adjustment values Information These steps are not necessary for instruments which are already preset acc to customer specifications VEGABAR 53 4 20 mA HART VOOLSO N3 LSZ7c 27513 EN 051004 VEBA Select application Level measurement A Select adjustment unit den sity unit VEGABAR 53 4 20 mA HART Setup with the indicating and adjustment module PLICSCOM You can find these data on the type label on the instrument and in the menu items of the min max adjustment PLICSCOM enables the adjustment without filling or pressure You can carry out the settings in the workshop without the instrument having to be installed Also the current measured value is shown in the menu items for the min max adjustment VEGABAR 53 is preset to application Process pressure meas
34. nt flush O ring article no 2 27867 e Welded socket GB article 27866 gt Note the applicable welding standards segment welding procedure when welding the socket Use the appropriate seal e Process fitting GV GF GC Tesnit 6 2x17 5x1 article no 2 14815 seal in front of the thread Seal the thread with teflon hemp or a similar resistant seal material e Process fitting GN gt Screw VEGABAR 53 into the welded socket Tighten the hexagon screw on the process fitting Wrench size see dimensional drawings 2 f necessary position correction see Setup procedure Mounting 14 VEDA Warning The housing must not be used to screw the instrument in Applying tightening force to the housing can damage its internal mechanical components VEGABAR 53 4 20 mA HART 700190 3 1946 27513 EN 051004 VEBA Note safety instructions e Take note of safety instructions for Ex applications Select power supply Selecting the connection ca ble Cable gland 12 VEGABAR 53 4 20 Connecting to power supply 5 Connecting to power supply 5 1 Preparing the connection Always observe the following safety instructions e Connect only in the complete absence of line voltage e f overvoltages are expected overvoltage arresters should be installed Tip We recommend VEGA overvoltage arresters S F LB I and
35. of delivery application practical use and operating conditions of the sensors and processing systems correspond to the information avail able at the time of printing VEGA Grieshaber KG Schiltach Germany 2005 Technical data subject to alterations 27513 EN 051004
36. oundation Fieldbus An exchange of the same type is thus possible If there is no electronics module available on site it can be ordered from the responsible VEGA agency It can be ordered with or without serial number The electronics with serial number includes order specific data such as factory setting seal material etc The electronics without serial number includes no order specific data The serial number can be found on the type label of VEGABAR 53 or on the delivery note In both cases the function of VEGABAR 53 is ensured 8 4 Instrument repair If it is necessary to repair VEGABAR 53 please proceed as follows You can download a return form 23 KB from our homepage www vega com under Services Downloads Forms and Certificates Repair form By doing this you help us carry out the repair quickly and without having to call back for needed information e Print and fill out one form per instrument e Clean the instrument and pack it damage proof 43 Maintenance and fault rectification e Attach the completed form and possibly also a safety data sheet to the instrument e Send the instrument to the respective address of your agency In Germany to the VEGA headquarters in Schiltach AA VEGABAR 53 4 20 mA HART 700190 3 1946 27513 EN 051004 VEBA VEGABAR 53 4 20 mA HART Dismounting 9 Dismounting 9 1 Dismounting proce
37. ow tightly back on Removal is carried out in reverse order PLICSCOM is powered by the sensor an additional con nection is not necessary VEGABAR 58 4 20 mA HART 700190 3 1946 27513 EN 051004 VEBA VEGABAR 53 4 20 mA HART Setup with the indicating and adjustment module PLICSCOM Fig 16 Installation of PLICSCOM Note If you intend to retrofit VEGABAR 53 with a PLICSCOM for continuous measured value indication a higher cover with an inspection glass is required 25 Setup with the indicating and adjustment module PLICSCOM W a Key functions Adjustment system 26 6 3 Adjustment system Fig 17 Indicating and adjustment elements 1 LC display 2 Indication of the menu item number 3 Adjustment keys e OK key move to the menu overview confirm selected menu edit parameter save value e gt key to select menu change list entry editing position e modify value of a parameter e ESC key interrupt input jump to the next higher menu The sensor is adjusted via the four keys of the indicating and adjustment module The LC display indicates the individual menu items The functions of the individual keys are shown in the above illustration Approx 10 minutes after the last pressing of a key an automatic reset to measured value indication
38. ower supply unit Note With power supply units with integrated HART resistor inner resistor approx 250 Ohm there is no additional external resistor necessary This applies e g for VEGA instruments VEGATRENN 149A VEGADIS 371 VEGAMET 381 Also standard Ex separators are normally equipped with a sufficient current limitation resistor In these cases VEGACONNECT 3 can connected in parallel to the 4 20 mA cable 7 2 Parameter adjustment with PACTware Further setup steps are described in the operating instructions manual DTM CollectiorvPAC Tware attached to each CD and which can also be downloaded from our homepage A detailed description is available in the online help of PACTware and the VEGA DTMs 39 40 Setup with PACTware and other adjustment programs W a i Note Keep in mind that for setup of VEGABAR 53 DTM Collection 11 2002 or a newer version must be used All currently available VEGA DTMs are provided in the DTM Collection on CD and can be obtained from the responsible VEGA agency for a token fee This CD includes also the up to date PACTware version The basic version of this DTM Collection incl PACTware is also available as a free of charge download from the Internet Move via www vega com and Downloads to the item Software 7 3 Parameter adjustment with AMS and PDM For VEGA sensors instrument descriptions for the adjustment programs AMS
39. partment Fig 5 Electronics and connection compartment single chamber housing 1 Plug connector for VEGACONNECT I7C interface 2 Spring loaded terminals for connection of the external indication VEGADIS 61 3 Ground terminal for connection of the cable screen 4 Spring loaded terminals for power supply 18 VEGABAR 58 4 20 mA HART 700190 3 1946 27513 EN 051004 VEBA Wiring plan Housing overview VEGABAR 53 4 20 mA HART m py E Connecting to power supply Fig 6 Wiring plan single chamber housing 1 Power supply Signal output 5 4 Wiring plans double chamber housing The following illustrations apply to the non Ex as well as to the Ex ia version The Exd version is described in the next subchapter Fig 7 Double chamber housing Housing cover connection compartment Blind stopper plug M12x1 for VEGADIS 61 option Housing cover electronics compartment Filter element for pressure compensation or blind stopper with version IP 66 IP 68 1 bar Cable entry or plug 3 Version IP 66 IP 68 1 bar not with four wire instruments 19 Connecting to power supply Electronics compartment Connection compartment 20 VEBA SS Fig 8 Electronics
40. r Yo Or e 1x plug depending on the version 1x blind stopper M20x1 5 Double chamber housing e 1xcable entry M20x1 5 cable 2 5 9 mm 1x blind stopper M20x1 5 plug M12x1 for VEGADIS 61 option Or e 1x closing cap 1x blind stopper NPT plug M12x1 for VEGADIS 61 option Or e 1x plug depending on the version 1x blind stopper M20x1 5 plug M12x1 for VEGADIS 61 option Spring loaded terminals for wire cross sections up to 2 5 Electromechanical data version IP 66 IP 68 1 bar Version IP 66 IP 68 1 bar is only available for instruments with absolute pressure measuring ranges 1 Depending on the version M12x1 acc to DIN 43650 Harting Amphenol Tuchel 7 8 FF 50 VEGABAR 58 4 20 mA HART 700190 3 LSZ 27513 EN 051004 VEBA Cable entry Single chamber housing Double chamber housing Connection cable Configuration wire cross section wire resistance tensile load Standard length max length Min bending radius Diameter Colour standard PE Colour standard PUR Colour Ex version Indicating and adjustment module Power supply and data transmission Indication Adjustment elements Protection unassembled mounted into the sensor without cover Materials Housing Inspection window VEGABAR 53 4 20 Supplement e 1x IP 68 cable en
41. sposal VEGABAR 53 4 20 700190 3 1946 27513 EN 051004 VEBA Scope of delivery Components VEGABAR 53 4 20 mA HART Product description 3 Product description 3 1 Configuration The scope of delivery encompasses e VEGABAR 53 process pressure transmitter e Documentation this operating instructions manual test certificate Ex specific safety instructions with Ex versions and if necessary further certificates Operating instructions manual ndicating and adjust ment module PLICSCOM optional Supplementary instructions manual Plug connector for continuously measuring sensors optional VEGABAH 53 consists of the following components e Process fitting with measuring cell e Housing with electronics optionally available with plug connector e Housing cover optionally available with indicating and adjustment module PLICSCOM The components are available in different versions Fig 1 Example of a VEGABAR 53 with manometer connection G 2A acc to EN 837 and plastic housing 1 Housing cover with integrated PLICSCOM optional 2 Housing with electronics 3 Process fitting with measuring cell Product description Area of application Physical principle Power supply Packaging 10 VEBA 3 2 Principle of operation VEGABAR 53 is a pressure transmitter for measurement of gauge pressure absolute
42. stment module PLICSCOM in the menu item Copy sensor data The data remain there even if the sensor power supply fails If it is necessary to exchange VEGABAR 53 PLICSCOM is inserted into the replacement instrument and the data are also written into the sensor under the menu item Copy sensor data 37 Setup with PACTware and other adjustment programs WI a Connecting the PC directly to the sensor 38 7 Setup with PACTware and other adjustment programs 7 1 Connecting the PC Power supply Fig 18 PC connected directly to the sensor 1 2 3 RS232 connection VEGABAR 53 adapter cable for VEGACONNECT Necessary components VEGABAR 53 PC with PACTware and suitable VEGA DTM VEGACONNECT with I C adapter cable article no 2 27323 Power supply unit VEGABAR 58 4 20 mA HART 700190 3 1946 27513 EN 051004 VEBA Connecting the PC to the signal cable VEGABAR 53 4 20 mA HART Setup with PACTware and other adjustment programs VEGACONNECT 3 af Fig 19 Connecting the PC to the signal cable 1 RS232 connection 2 VEGABAH 53 3 HART adapter cable for VEGACONNECT 4 HART resistance 250 Ohm Necessary components e VEGABAR 53 e PC with PACTware and suitable VEGA DTM e VEGACONNECT with HART adapter cable art no 2 25397 e resistance approx 250 Ohm e P
43. to these personnel and put into practice by them 1 8 Symbolism used Information tip note This symbol indicates helpful additional information Caution warning danger This symbol informs you of a dangerous situation that could occur Ignoring this cautionary note can impair the person and or the instrument Ex applications This symbol indicates special instructions for Ex applications List The dot set in front indicates a list with no implied sequence Action This arrow indicates a single action Sequence Numbers set in front indicate successive steps in a procedure For your safety VEBA 2 your safety 2 1 Authorised personnel All operations described in this operating instructions manual must be carried out only by trained specialised personnel authorised by the operator For safety and warranty reasons any internal work on the instruments must be carried out only by personnel authorised by the manufacturer 2 2 Appropriate use VEGABAR 53 is a pressure transmitter for measurement of gauge pressure absolute pressure and vacuum 2 3 Warning about misuse Inappropriate or incorrect use of the instrument can give rise to application specific hazards e g vessel overfill or damage to system components through incorrect mounting or adjustment 2 4 General safety instructions VEGABAR 53 is a high tech instrument requiring the strict observance of standard regulations
44. trip approx 1 cm 0 4 in insulation from the ends of the individual wires 5 Insert the cable into the sensor through the cable entry 6 Lift the opening levers of the terminals with a screwdriver see following illustration 7 Insert the wire ends into the open terminals according to the wiring plan VEGABAR 58 4 20 mA HART VOOLSO N3 ISZc 27513 EN 051004 V mum VEGABAR 53 4 20 Connecting to power supply Fig 3 Connection steps 6 and 7 8 Press down the opening levers of the terminals you will hear the terminal spring closing 9 Check the hold of the wires in the terminals by lightly pulling on them 10 Connect the screen to the internal ground terminal and the external ground terminal to potential equalisation 11 Tighten the compression nut of the cable entry the seal ring must completely encircle the cable 12 Screw the housing cover back on The electrical connection is finished 5 3 Wiring plans single chamber housing The following illustrations apply to the non Ex as well as to the Ex ia version 17 Connecting topowersuppy Housing overview Fig 4 Material versions single chamber housing Plastic Aluminium Stainless steel Filter element for pressure compensation or blind stopper with version IP 66 IP 68 1 bar Electronics and connection com
45. try M20x1 5 1x blind stopper M20x1 5 Or e 1x closing cap NPT 1x blind stopper Yo e 1x IP 68 cable entry M20x1 5 1x blind stopper M20x1 5 plug M12x1 for VEGADIS 61 option e 1 closing cap 72 1x blind stopper Y NPT plug M12x1 for VEGADIS 61 option four cores one suspension cable one breather capillary screen braiding foil mantle 0 5 mm lt 0 036 Ohm m gt 1 200 N 270 pounds force 5 m 16 4 ft 1000 m 3280 ft 25 mm with 25 C 77 F approx 8 mm Black Blue Blue through sensor via gold plated sliding contacts 12 bus LC display in full dot matrix 4 keys IP 20 IP 40 ABS Polyester foil 51 Suplemen sss Supply voltage Supply voltage non Ex instrument 14 36 V DC EEx ia instrument 14 30 V DC instrument 20 36 V DC Permissible residual ripple 100Hz Uss 1 V 100 Hz 10 kHz Uss 10 mV Load see diagram Q 1000 750 500 250 Fig 20 Voltage diagram HART load Voltage limit EEx ia instrument Voltage limit non Ex Exd instrument Supply voltage Electrical protective measures Protection All housings standard IP 66 IP 6718 Alu and stainless housing optionally IP 66 IP 68 1 bar available Overvoltage category 11 Protection class 18 Instruments with gauge measuring ranges can no longer detect the ambient pr
46. uence 1 Select the adjustment unit 2 Carry out position correction 3 Carry out zero adjustment 4 Carry out span adjustment In the menu item Units of measurement you select the physical unit in which the adjustment should be carried out e g mbar bar psi The position correction compensates the influence of the mounting position or static pressure on the measurement It does not influence the adjustment values In the menu items zero and span you determine the span of the sensor the span corresponds to the end value 27 Setup with the indicating and adjustment module PLICSCOM W a i Select the adjustment unit Carry out position correction 28 Information These steps are not necessary for instruments which are already preset acc to customer specifications You can find these data on the type label on the instrument and in the menu items of the zero span adjustment PLICSCOM enables the adjustment without filling or pressure You can carry out the settings in the workshop without the instrument having to be installed In addition to the menu items for zero span adjustment the current measured value is displayed To switch over to another adjustment unit in the example from bar to mbar proceed as follows 9 1 Push the OK button in the measured value display the menu overview is displayed gt Basic adjustment Display Diagnostics Service Info 2
47. urement Proceed as follows when switching over to application Level measurement 1 Push the button in the measured value display the menu overview is displayed 2 Select the menu Service with gt and confirm with OK Basic adjustment Display Diagnostics gt Service Info 3 Select the menu item Application with and edit with OK Warning Note the warning Output can change 4 Select OK with gt OK and confirm with OK 5 Select Level from the list and confirm with OK To switch over to another adjustment unit in the example from bar to mbar proceed as follows 1 Push the OK button in the measured value display the menu overview is displayed gt Basic adjustment Display Diagnostics Service Info 2 Confirm the menu Basic adjustment with OK the menu item Units of measurement will be displayed 7 Selection options mbar bar psi Pa kPa MPa inHg mmHg inH2O mm cm m in ft 31 32 Dale Setup with the indicating and adjustment module PLICSCOM WI IE Units of measurement bar Activate the selection with OK and select the requested unit with gt in the example mbar Confirm with OK and move to position correction with gt The adjustment unit is now changed from bar to mbar Information When changing over to a height unit in the example from bar to m

Download Pdf Manuals

image

Related Search

Related Contents

EPOCRYL-HAFTPRIMER RAL 7032 - L 6659  EasyDive Jaeger 400 USER GUIDE  Saunders Lumbar Traction Devices User's Guide  小さなボディに、驚きの高性能!  RECEPTOR MUNDIAL Yacht Boy 400 PE  Barco Projector 9200 User's Manual  Samsung Schneider D-XENOGON 35 User's Manual  Guia_ESTRUTURA ATÔMICA_19.11.09  Frigidaire FPCO06D7MS Owner's Guide  0210-Influenza A  