Home

Installation Manual Wireless Water Sensor - Super-Sail

image

Contents

1. AA C LED Page 2 of 7 N Installation Manual ail Mounting If the Water sensor is placed on a plane surface even moisture will activate the sensor It is thus possible to install it where water is not expected even in small amounts The smallest amount of water will activate the sensor If the Water sensor is placed in the keel where some water can be expected the Water sensor must be lifted from the surface The Water sensor is mounted using screws Velcro or heavy two sided tape which allows for dismounting for exchanging batteries Installation of Batteries The Water sensor use 2 x LR6 Mignon AA batteries We recommend to use Alkaline batteries of good quality to achieve long battery life time 1 Open the Water sensor by loosening the 4 screws in the waterproof transparent cover and remove the cover carefully 2 Loosen the 4 plastic screws which holds the cover plate to the battery holder and remove the cover plate carefully 3 Install 2 pcs batteries LR6 AA in the battery holder and fasten the cover plate again using the 4 plastic screws 4 Put the waterproof transparent cover in place and fasten using the 4 screws Ty Used batteries should not be disposed a domestic waste yiv A f f LA Batteries should be disposed according to the local regulations for batteries ir After installation of Batteries After installing new batteries the Water sensor will run a self test This will normally be finished after
2. approx 2 seconds Faultless execution of the self test is indicated by blink with the LED red green and orange each turned on for 0 5 second If an error is discovered by the self test this will be indicated by blink with the red light 1 long blink 2 short blink pause Battery level low repeated 2 times Exchange the batteries 1 long blink 1 short blink pause Sensor defect repeated constantly Exchange the unit Even that the battery level is low and as long as the battery level allows for it the Water sensor will remain active and report status to the Alarm system If the Water sensor is not able to send status due to low battery level the error code will be shown again by the LED Page 3 of 7 Js Installation Manual ail Testing the Water Sensor When the Water sensor is installed and activated in the Alarm system the function of the Water sensor must be tested Put the Water sensor on a wet dishcloth or similar When the Water sensor after a few seconds register water on the dishcloth the green LED in the sensor is turned on shortly After some seconds depending on the time for SMS transfer an Alarm SMS must be received indicating alarm from the Water sensor Remove the Water sensor from the wet dishcloth When the Water sensor after a few seconds register no water the green LED is turned on shortly After some seconds depending on the time for SMS transfer an Alarm SMS must be received indicating th
3. at the alarm from the Water sensor is canceled Fault search e The green LED is not turned on when the Water sensor is wet Remove the batteries and re insert them verify that they are aligned correctly Self test as described above under After Installation of Batteries will verify if there are any faults on the Water sensor e LED is turned on but SMS is not received Verify if the Water sensor is activated correctly in the Alarm system as described below under Activation in the Alarm system Verify that the Water sensor ID is keyed in correctly Reset to Factory settings If the Water sensor for some reason does not function and the batteries have been changed without solving the problem reset to Factory settings can be a solution to fix the problem 1 Press and hold the button A for 5 seconds until the LED C starts blinking slowly with red light release the button 2 Press and hold the button for further 5 seconds until the LED starts blinking faster red 3 Release the reset button to finish the reset procedure The LED light up red in 3 seconds to confirm the reset The Water sensor is reset to Factory settings Page 4 of 7 N Installation Manual ail Maintenance The Water sensor is maintenance free Repairs should be carried out at an authorized service center Cleaning can be carried out with a soft cloth wrenched in lukewarm water Cleaning detergent containing sol
4. s the Water sensor This ID is unique for the Water sensor and makes it possible for the Alarm system to separate the wireless sensors Save the ID in case the ID should be deleted from the app and need to be re installed later In the Type filed you choose Water which specifies that the Water sensor is of the type Water sensor Finally the sensor is activated by ticking the field next to the Text filed This activates the sensor in the Alarm system When the alarm is turned on this sensor will be included in the alarm It is recommended to activate the alarm and test that an alarm SMS is sent if the Water sensor is activated Page 6 of 7
5. uper qil Js Installation Manual ail Table of Contents EN AA A III 2 KETAT IN e E E EE E 2 MOUNTINO oee E E EE 3 INSTALLATION OF DATTERIE S ienie a E a a a a lo rcotadicds 3 AFTER INSTALLATION OF BATTERIES sean 3 TESTING THE WATER SENSOR 2 nadan 4 RESET TO PACTORYSETTINOS ostias A MAINTENANCE ee EE S 5 TECHNICAL SPECIFICATION errado ee ee ee ee 5 SATTE POST se A E ee een 5 ACTIVATION IN THE ALARM SYSTEM iio 5 Page 1 of 7 N Installation Manual ail Getting started Congratulation with your new SuperSail product We hope that you will be satisfied with the product and we are always available to give support in case you need it You can contact us at support super sail dk Regards SuperSail Support Team Please read the whole installation manual before starting the installation Unpacking Before you start using the unit you must ensure that the packaging has not been broken or have been injured during transport and that the product is complete and without any visible sign of damage or strained If this is not the case please contact SuperSail before using the product The Wireless Water sensor measures via 5 electrodes if water is present on the surface where it is installed The Water sensor is driven by batteries and can be places anywhere where you want to be noticed if water is detected Sensor electrodes A Reset button B Battery holder 2 pcs 1 5 V Mignon Batteries LR6
6. vent can harm the unit Technical Specifications Radio frequency 868 3 MHz Typical outdoor range 100 m Power 2 pcs 1 5V LR6 AA Mignon Battery life time approx 3 year Protection IP65 Size 115 x 65 x 55 HxBxD Changes may apply Safe Disposal Z Should not be disposed a domestic waste y Y A A Electronic equipment should be disposed according to the local regulations A 4 for electronic and electronically equipment Activation in the Alarm system A ter installation and test the Water sensor must be activated in the Alarm system This is performed via the SuperSail app where the Water sensor is activated via the Alarm menu 14 34 SuperSail ALARM Carsten Tracker ID Max Afstand 100 Max Chockpavirkning 1500 Sensorer Sensor 1 Tekst Vandtank ID 1355375 Type Vand Sensor 2 Tekst SensorText SLUKKET Page 5 of 7 Js Installation Manual ail In the above example we have decided to activate the Water sensor as sensor 1 but all sensors are available for all sensor types In the Text field you can write a short text which identifies the installation of the Water sensor This text will be transmitted in the Alarm SMS in case the Water sensor is activated It is therefore important that the text identifies the individual Water sensor In the ID field you write the ID written on the side of the Water sensor The ID is furthermore written on the Quick Guide which follow

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書  Ape50/100 テールランプキット 取扱説明書  Consulter le document en PDF - Bureau de la sécurité des  USER MANUAL - Kramer Electronics  Reporter Lift II  [U4.52.13] Opérateur CALC_AMOR_MODAL  PRÊTRES EN VAUCLUSE  ANEJO Nº5.- INSTALACION ELÉCTRICA  HP StorageWorks Modular Smart Array 1000/1500 Command Line  KayakFoundry – User Manual  