Home
User manual for Contool 2000XP - Conson Concept 2000XP home
Contents
1. vi Intro bottom T this is nothing but an estimate so I suggest that we arrange a meeting where we can discuss your plans in details vi Offer text Al vi Unit list ETE F z S Unit name No Costprice Discount Profit api Price apie Sub total Discount Sub total XP11 5703513054 1 99 66 4 98 9 97 104 64 104 64 i 104 64 XP130 5703513055 1 221 21 0 00 0 00 221 21 221 21 221 21 XP33UNI 5703513058 1 265 84 0 00 0 00 265 84 265 84 265 84 XP31UNI 5703513057 1 365 84 0 00 0 00 365 84 365 84 A 365 84 XP24 5703513059 2 500 00 0 00 0 00 500 00 1 000 00 R 1 000 00 xP09 5703513054 1 15 32 0 00 0 00 15 32 15 32 f 15 32 YD 2606 57n2512N5A 2 nonl nanl n na oan Don a pol Price text installation needed anyway Therefore the total cost will not be much higher Additionally the al power consumption for your household will decrease so in long terms both finances and environment will gain from this solution vi Ending The text of the template is editable but the layout is fixed In order to see the layout press the Print preview icon located in the red square Doing so will open the following dialog which enables you to select the documents you want to have displayed The Unit list and Invoice part will be described in their own sections later on Select the desired print outs Unit list Invoic
2. The XP130 sub tree is only present if any units requiring upload through the XP130 are present and these units have a valid serial number All XP actor modules and all XP sensors are placed in the XP130 sub tree Cancel Ok Both XP78 and XP130 units have an extra level assigned to them this level displays information of which units are connected to their inputs for sensors or outputs for modules This information is available to enhance the overview of each unit Moving the mouse over a XP sensor on the list like 0020012497 XP2606 Floor plan 1 will make the application switch to the floor plan containing that specific XP sensor and mark it by displaying its info panel The bottom section named Conbeam upload method is only of interest if uploading through the Conbeam XP78 Besides the COM port described in 12 2 1 it holds two options e Module to send the data directly to each modules e Conkey to send the data to the XP79 Conkey Afterwards this can be used to transfer the data to each individual module by hand Contool 2000xp keeps track of which units are in need of being updated and these will already be selected when opening the dialog It is possible to change the selection but usually it is recommended to let the application handle which units to update 24 Units from the old Concept 2000 and new XP variants XP20 XP70A XP70B XP70C or XP70D MKJ 2011 02 25 page 40 of 53
3. Preferably the image should be the same size as the floor plan view port area Since it is possible to resize Contool 2000xp to fit different screen solutions a fixed size cannot be set However if you use the standard window size of Contool 2000xp you can import images with a 650 x 580 pixels resolution Importing larger images will place scrollbars in the viewport allowing you to scroll horizontally vertically across the entire image ee ULL ee CN KE d E Zei 3 iP x Set Yew rege Lore Tow sop Fes Gott AA 3 Asto sterk section Pros see mage NM smed bl gert pp Image size with HE v Ol Hat ete vw pice v ts weer X recut wo 7 RE B pakn E Quality F scher Loar krzedc glsgerz ap zunn socked vha Fher pabon The chosen interpolebon ts wi affect haet ard made criy 3 MKJ 2011 02 25 page 17 of 53 If you wish to resize a larger image to fit the floor plan viewport use an image editing application Several applications can be downloaded free of cost from the Internet e g GIMP After downloading and installing GIMP all you need to do is to open the image you wish to resize With the image file opened select the menu Image Scale Image In the dialog that appears you simply enter the width and height of the floor plan viewport and press the Scale button Finally save the image and you are ready to import it
4. This will make the unit blink both on the floor plan as well as the real life installation making it easy to identity the unit The menu item is only enabled if online e Start rotate is available for all XP sensors This will the unit enter rotate mode just like pressing the start listening in 7 2 4 The menu item is only enabled if online e Stop rotate is available for all XP sensors This will make the unit exit rotate mode The menu item is only available if online 7 1 5 Drawing lines Lines can be drawn coloured and deleted anywhere on the floor plan by doing the following e Hold down the W key on the keyboard to start drawing a straight line from the original mouse coordinates Release the W to end the line e Press the T key to switch the colour of the latest line There are 7 different colours available e Press the D key to delete the latest line or the C key to clear all lines The scope of the T D and C commands are the current floor plan Consequently pressing C will only clear the lines on the currently selected floor plan All of the above actions only apply if the floor plan is in focus Do so by clicking anywhere on the floor plan 7 2 The action panel The top part of the action panel in design state consists of four tabs 1 Floor plans used to add remove copy rename and replace blueprint images 2 Floor plan links used to create links between flo
5. Both the wap and the www html setup need file permission to write and modify files and subfolders at the file server path 16 1 1 External access Which IP host name to enter in this section depends upon how remotely it must be possible to access Contool 2000xp MKJ 2011 02 25 page 52 of 53 1 If Contool 2000xp and web server are installed on the same computer as the access is needed 127 0 0 1 or localhost is the right choice This is rarely the case but it is sufficient for demo purposed 2 If Contool 2000xp must be accessed from a computer running on the same LAN the IP address of the network adapter found on the computer running Contool 2000xp is the right choice 3 If Contool 2000xp must be accessed from a computer running outside the LAN the IP address must be the global IP of the LAN on which Contool 2000xp is installed or a hostname pointed to the global IP of the LAN Furthermore the router on the LAN must forward the traffic on the entered port default 9090 using NAT to the IP address of the network adapter found on the computer running 2000xp 16 1 2 Wap setup In order to enable Wap support start by check the box Mobile phone light control service enabled The server URL is simply the URL to access your web server e g mydomain com conson wap The file server path must be specified with a drive letter e g C inetoub wwwroot conson wap Consequently it is far th
6. This will open a dialog with functionality to update the firmware by selecting which firmware version to update to The newest firmware files are always shipped with Contool 2000xp e View action table is available for all XP actors and XP sensors and opens a dialog with the serial number link number and content of the action table e Actor console is available for all XP actors The functionality is described in details in 8 1 4 e Actor programming is available for all XP actors The functionality is described in details in 8 1 4 e Setup alert is available for all XP actors The functionality is described in details in 8 1 6 e Configure webcam is available for webcams The functionality is described in details in 8 1 7 e Configure is available for eyes The functionality is described in details in 8 1 8 e Connect eye is available for remotes needing eyes The functionality is described in details in 8 1 9 e Upload single module is available for actors The functionality is described in details in 8 1 10 Remotes are by definition also sensors MKJ 2011 02 25 page 21 of 53 8 1 4 Right click menu Actor console Selecting the Actor console from the right click menu opens a dialog with three features 1 Enable auto reporting only available if online This is used to enable actor event on make and break and is by default turned off to reduce traffic on the bus See 8 1 5 for furth
7. URL used to delete the action on the control This is only available if there is only one action defined on the control When right clicking an item in the popup list you will get the following options e Delete item used to delete the selected action e Edit name used to rename the selected action This is buggy in revision 2670 It is possible to drag and drop a URL for instance from the address field of the browser window to one of the 18 controls in the usage state in Contool By doing so the URL will be saved as a new action and added to the bottom of the list By dragging the complete path of a locally installed programme or document like C Program Files Microsoft Office Office 12 Outlook exe it is also possible to add this as an action In the popup list the items actions can be sorted by dragging them to a new position 9 2 2 Sensor Clicking a sensor on the floor plan to the left brings up a zoom of the current sensor Pressing the push panels of this sensor will make Contool 2000xp trigger functions on the live modules as if you were pressing the same push panel in real life MKJ 2011 02 25 page 29 of 53 10 Floor plan The settings menu The Settings menu found at the top menu in Contool 2000xp contains a series of application wide settings Items enclosed in green are solely related to the floor plan and they are shown with their default settings 10 1 1 Invert function Help Languages gt When se
8. export a project choose Files Export Project to files This will open a file dialog where you can save amp Documentation point to the folder where your export files should Save 35 Export Fohl GW go It is very important that the folder is empty before exporting to it Export Project to files Import Project from files You can also create a new folder in the file dialog Disconnect Quit i To import the project in another version of Contool 8 the first step is to create a new empty project in offline mode After the export the folder is populated with a con file for each module in the system a floor plan table fto and the graphic files for each floor plan If you want to exchange projects with others you can zip the entire folder 4 2 2 Importing files Start the project and choose Files Import Project from files as the first action in the project browse to your export folder and press Open After a while you should get the Project import successful dialog Note that importing big projects may take a couple of minutes to complete Now you Can save your project as a normal Contool project To go online with the system choose Files Disconnect uncheck the Offline mode checkbox in the project view and start the project again 4 3 Downloading data from modules If you lose a project file it is still possible to recreate a project from data i
9. into Contool 2000xp as your floor plan background Notice that a new floor plan image should not exceed 200kb Otherwise it might have a severe performance penalty on Contool 2000xp 72 2 Floor plan links The floor plan links offers the ability to draw Design tools polygon links which work as a shortcut between floor plans This is a useful feature when having a project with multiple floor plans like a house where a stair in the r D tate inal ground floor could be turned into a link BEE v which leads to the upper floor When created a link set it in Design state press the add button and click on the floor Link target plan where you want the polygon to start Each click will create a new edge to the polygon and dragging the highlighted edges will resize the polygon The link target holds the floor plan which the polygon will link to Finish off by setting the state to test state Floorplan links 7 2 3 Sensors actors All units are located on the Design tools Sensors actors tab on drop down menus Sensors are units like push buttons Floorplan links l Floorplans Sensors actors remotes PIR detectors etc which all trigger actions on actors which are SE outlets lamps motors fan etc re By clicking a unit this unit sticks to the el el D es gt EN mouse cursor which is moved inside the Actors main panel the floor plan to the left After xp XP ver om
10. is selected In order to switch to the project price list go to the Settings menu and select the project pricelist which is marked with a dark background colour How to create custom unit will be explained in detail later on at installation path PriceLists at installation path Projects Project name Pricelist MKJ 2011 02 25 page 48 of 53 13 2 3 Adding and removing units to the quotation As stated earlier all units added through the floor plan and fuse box tabs are automatically added to the quotation Besides adding and removing units through these tabs it is also possible to add units directly to the quotation In order to remove placed units from the unit list go to the Floor plan tab in design state and use the arrow controls underneath the top unit list table to remove un remove units from the quotation In order to add further units to the quotation go back to the Quotations tab and the inline tab Unit list management and use the controls in the upper part marked in a red square The top row makes it possible to enter any text while the bottom row makes it possible through a drop down list to select any unit found in Contool 2000xp as well as selecting custom units The built in Contool 2000xp units are located at the top of the list while the custom units are located at the bottom A dotted line in drop down list separates the two But notice that all manually added units only appear i
11. off Be careful to test whether your SMTP server filled in at the bottom of the dialog allows you to sent out e mails without SMTP Authentication Finally beware that the message type SMS is not implemented in this version Configure alerts on module Output Enable Trigger type Subject Message Message type Receiver email address mobile no 1 XP33 Lamp dimable 3 x 210 VA Uni Off v E mail e 2 XP33 Lamp dimable 3 x 210 YA Uni Off v E mail v 3 XP33 Lamp dimable 3 x 210 VA Uni Off vi E mail e Email Configuration SMTP Server From email address Verifying this is beyond the scope of this user manual MKJ 2011 02 25 page 22 of 53 8 1 7 Right click menu Configure webcam The menu item Configure webcam opens the regular webcam viewer in Contool 2000xp Pressing the Setup button will open another dialog used configure the stream to display in the webcam viewer It is possible to connect to either a USB camera or an HTTP IP camera The latter is very easy since it is typically merely a question of filling in the correct URL and this URL can be tested by using the external viewer found at the bottom of the dialog The former USB can be a little more tricky It needs a viewer application which is usually shipped together with the web cam For easy of use a simple viewer is shipped together with Contool 2000xp at installation path USBWebCamViewer WebCamViewer exe 8 1 8
12. output they are connected first output to the far left last output to the far right MKJ 2011 02 25 page 46 of 53 13 Quotation A quotation module is available in the application to generate quotations unit lists and simple invoices A toolbar is placed at the top of the quotation tab with controls related to the current quotation marked in a red square and controls related to templates marked in a yellow square which will be described in details later on Underneath this toolbar are two inline tabs Quotation text and Unit list management 13 1 Quotation and template The inline tab Quotation text holds a series of editable text snippets stored in templates The template is selected in the yellow square which also holds icons to save save as and delete the currently selected template Quotation el g emplate BEEN ea vi g iA x Quotation text Unit list management Name Customer name re Customer address line 1 a Customer address line 2 Customer address line 3 K Attention x SE e P i Concerning quotation for Concept 2000 the intelligent installation Headline l F r z According to a pleasant conversation hereby send you this suggested quotation for a Concept 2000 installation Intro top Conson Elektronik or Bang amp Olufsen automatically detecting direction of vehicles surveillance a and logging via a PC burglar alarm panels for overview and much more
13. using an example We have a curtain and an up button and a down button We want to be able to stop the curtains at any time If we for instance press Up while the curtain is already moving in that direction we want it to stop So both the Up and Down button must do up stop up and down stop down when pressed multiple time We also want the relays to go off after one minute to remove power supply from the motor when not needed MKJ 2011 02 25 page 33 of 53 Say the up direction is controlled by Relay 1 Output 1 of the XP24 and the down direction by output 2 To program the desired function in programming state select a push panel from the floor plan then select the button that should be used for Up Click the motor and add Toggle 1 min on the Output 1 tab Then select the Down button on the sensor and click the motor again Now select the Output 2 tab and add another Toggle 1 min function Below is shown how the programming looks in Contool Functions for actor AC motor curtain state Programming state Usage state Actor AC motor curtain Choose module or name xP 2506B or placement Dinner Table RW P Garten Up Output 1 Member of All on Push panel feedback Member of All oft Function Parameter Invert Switch on time E 0 sec vi Function Parameter Invert gt E AC motor curtain
14. v and add the decrease function to each light Finally press 0 followed by GO and add the off function to each light Then press 1 followed by A and add a level increase function to light 1 The rest is programmed in the same manner Now all 3 lights can be controlled together with group 0 for instance increasing light level for all lights are done pressing LIGHT followed by A To decrease light for light 3 press LIGHT 3 and V 2 You do not need to press LIGHT if the remote control is already in LIGHT mode MKJ 2011 02 25 page 37 of 53 12 Fuse box Modules can be added to the fuse box in four different ways 1 When sensors actors are added to the floor plan which requires a module and no vacant modules are available See 7 2 3 for further details 2 When modules are added manually using the Add button and dialog located at the action panel associated with the fuse box tab 3 When detecting modules which only apply to XP 24 XP 31 and XP 33 modules See 6 for further details 4 When downloading module data using the download button and dialog located at the at action panel associated with the fuse box tab In either case added modules are placed at the first vacant slot which most likely does not match the real life fuse box 12 1 Moving modules around In order to make the virtual fuse box in Contool 2000xp match the real life fuse box the first step is to identify the module
15. 28 g2 The e leie e EEE EE 28 9 2 1 WIS GCM Te UE 28 NNN 29 10 Floor plan The settings men 30 10 1 1 Invent Te EEE ENER 30 10 1 2 Automatic Gopnpnechon 30 10 1 3 Show connection lines cece ceeccceeccsececeeecceeeceuceceeecsueeceueecseeseueesseesaueessueeseeessusenaess 30 VA NNN 30 10 1 5 Fire on select in programming State ccccccecceeeceeeceeeceeeseeeseeeseeseeeseeeseeeneeeneeenes 31 10 1 6 Fire on select in usage stole 31 11 ROO Mr COX ale UE 32 PE E US Ee ER V RE Turn 32 MKJ 2011 02 25 page 3 of 53 ME FP le EE ER Teko Menn I EEE NE 32 11 1 4 A note on the Fan symbol and sSb2A xb2Abn 33 TRZ 70 00 0 eege 33 11 2 1 e ie TE Lee LE 33 11 2 2 Programming Curtams 33 11 2 3 All on All off functions with curtains cece cc ceeeceeeceeece cena esse esse eesaeesaeesaeeseeeneeeneeenes 34 11 24 Direct programming WE 35 Ae NINE 35 VS EE 35 11 3 1 BEO4 remote control Light groupe 36 RE Pr 37 12 EIN Jo E 38 12 1 Moving modules around 38 NN ATP 38 12 1 2 Identifying an XP module rrrnnrnnnnennnnrranennnnennnrnnnnennnnnnnnennnnennnsnnnnennnrrnnnennnnennssnnnee 38 1212 00904 mod le Lead 38 12 1 4 Replacing a broken mocdule 39 12 2 Uploading data to modules rrrranrnnnnonnnrnranennnnnrnnrrnnnernnrnnnnrrnnnennarnnnnennnsennnsnnnsennnsennsennnee 39 12 2 1 Installing and detecting the Conbeam XA 39 12 2 2 Selecting data to upload orerranrrrnnnerranrrrnnnernnnrnrnnrernanrnrn
16. 8 Place Conbeam J CONBEAM Please place the Conbeam at CP70B row 2 column 2 in Fusebox named Fusebox 1 Before uploading each module through XP78 Contool 2000xp will prompt the user to place the Conbeam at the module If a connection cannot be established to the module the user will be prompted once again to move the Conbeam The connection is very sensitive to both a correct placement over the module as well as direct sunlight or similar Placing the Conbeam at the 2 groove from the left at the module and keeping a distance of about half a centimetre from the top edge of Conbeam to the module usually works well MKJ 2011 02 25 page 41 of 53 The retry dialog also holds the option to skip or to An error occured abort By pressing skip the current module will be skipped while moving to the next module in line By pressing abort all remaining modules will be skipped Notice that either option will result in an EG incomplete upload with no option to rollback the upload done to the modules sensor prior to skipping or aborting Conbeam could not connect with the module try moving it a little Please retry 12 3 Downloading data from modules The download section is located at the very bottom of the action panel Download of data is basically only a last resort if the project file is lost But it is a very powerful feature since it offers the possibility to restore a project from the most critical data stored in th
17. Current button Curtain Up Programming method G XP sensor All on All off 11 2 3 All on All off functions with curtains In the programming dialogue notice that curtain relays are not default members of the All on or All off group the way a normal lamp is This is because the system cannot know what All on or All off should mean for a curtain should it go up or down using which relay The All On All Off functionally has to be added manually In this example we want the curtains to go up on when All off is pressed We Giving the toggle function a time parameter will restrict its on time to the time parameter MKJ 2011 02 25 page 34 of 53 To do this select one of the All off buttons click the curtain actor on the floor plan which will bring up the programming dialogue Now select the output 1 tab output 1 was the up relay remember and add the function On 1 min to the tab With this function the relay 1 Up relay will go on for 1 minute each time an All off button is pressed 11 2 4 Direct programming If you right click the motor actor symbol and select the Program direct menu item you get the dialogue shown below XP 24 module programming Function Parameter Mutex block time Output 1 Usel v Dsec v Mutex 1 2 _ Blinds 1 2 Output 2 Toggle wl lose v 7 300 ms Output 3 Toggle VI Osec 500 ms Mutex 3 4 Blind
18. I XP24 The tree download mode is the only mode giving d n a AA access to download XP units through XP130 F 0020012509 1 XP24 Fusebox 1 pos 1 5 Download method for CP modules 1rConbeam COM port Conbeam Conkey Conbeam Module Conkey XP79 or directly from each module as well Ok Cancel Like the upload dialog it supplies an option to select if data from CP modules should be transferred through as entering detecting the COM port This option becomes available after having selected a module in the XP 78 sub tree 12 3 2 The CP interval mode This mode makes it possible to enter the module number of the CP modules to download as an interval The interval accepts both single numbers and ranges like 1 3 5 12 12 3 3 The CP anonymous mode The anonymous mode makes it possible to download an unspecified number of modules by simply placing the Conbeam on one module at a time Since the module numbers are unknown initially to Contool in this mode it is only possible to download directly from a module and not from MKJ 2011 02 25 page 43 of 53 Conkey This mode presents the Continue loading of modules user with a recurring dialog after downl oading each m odul em aking 2 Please place the Conbeam over module Press Ok when ready or cancel to stop loading modules it possible to continue with another module by pressing OK or stop loading more modules by pressing Cancel 12 3 4 D
19. If an installation behaves in an unexpected manner uploading all units is advisable in order to make sure all units are in sync with data in Contool 2000xp Do so by selecting the top nodes of the tree view and press Ok 12 2 3 Uploading data XP130 and XP78 Most of the upload process is fully automated and all you need to do is to wait for it to finish When doing so you can see the progress at the progress bars at the bottom of the upload section at the action panel The upload runs in the following order 1 XP130 transferring data a XP modules I Action tables for each module li Setup data for each module lil Contool data for each module b XP sensors i Action tables for each sensor li Setup data for each sensor lil Contool data for each sensor 2 XP78 transferring data a Action tables for each CP module Without going into too must details the action table holds the programming created in the floor plan by selecting which action a sensor event like the push of a push panel will have on an actor The setup data is the setup made by right clicking an actor on the floor plan or a module on the fuse box and selecting program direct The Contool data is the most critical data needed to restore a Contool 2000xp project if the project file is lost Only the modules and sensors programmed through XP130 are able to store the data needed to restore a project 12 2 4 Uploading data XP7
20. P11 199 66 15 00 110 00 XP20 183 48 0 00 0 00 XP24 500 00 0 00 0 00 XP24P 1500 00 XP31BC 1285 84 10 00 Dm XP31DD 315 84 10 00 10 00 XP31UNI 1365 84 10 00 10 00 XP33UNI 265 84 10 00 0 00 XP130 221 21 10 00 10 00 XPO9 115 32 10 00 10 00 CP70A 115 32 10 00 10 00 CP70B 115 32 10 00 0 00 CP70C 115 32 0 00 10 00 CP70D 115 32 10 00 0 00 CPX 1 push 10 00 0 00 10 00 CPX 2 push 10 00 10 00 0 00 CPX 3 push 10 00 10 00 10 00 CPX 2 x 2 push 10 00 10 00 10 00 CPX 2 x 3 push 0 00 0 00 0 00 M Copy price list 0 00 0 00 Finally the quotation part of Contool 2000xp is able to print out a simple invoice as shown in section 13 1 The layout is basically identical to the unit list except for invoice number and terms of payment which are filled out by the user prior to creating the print MKJ 2011 02 25 page 49 of 53 14 Documentation Documentation is automatically generated from the data present in the Fuse box and the Floor plans tab The documentation is divided in five reports which can be toggled on off at the action panel to the left Select reports to include in documentation Floorplan report The documentation is updated each time the Documentation l Floorplan 1 tab is selected or a report is toggled on off Fusebox report 14 1 Floor plan report Sensor report The floor plan report consists of a screen dump of each floor Actor report plan followed by a list of the sensors and actors as well as a Functio
21. Right click menu Configure The Configure menu item is only found at eyes and it opens a dialog for setting the channel for Configure webcam Camera data Camera name Webcam Camera placement description _ Description Camera connection 8 None USB camera viewer Viewer application Viewer parameters HTTPIIP camera URL http Updates minute Username if any Password if any External viewer HTTP IP URL http f XP eyes or for adding and connecting modules with channel and link for CP eyes 8 1 9 Right click menu Connect eye The Connect eye menu item is used to setup default connections for ease of use in the usage State If no eye is connected to an eye needing remote control selecting this remote control in usage state will prompt the user to select which eye to go through when operating the remote This step can be eliminated by setting up a default connection To connect to an eye select the Connect eye menu item on the remote and left click the preferred eye To disconnect repeat the same steps as when connecting To exit the connect eye state left click on an empty coordinate at the floor plan 8 1 10 Right click menu Upload single module The Upload single module is only found at actors and acts as a shortcut to upload data to the module which the current actor is connected to This will open the same upload dialog used when
22. This will probably not match the placement in the real life fuse box but it is easy to move the modules around First identify which module to move This can be done in two ways depending on whether it is a Concept 2000 CP or Concept 2000xp XP module 12 1 1 Identifying a CP module If it is a CP module the only identification possible is by using the module number field found at the top right corner of the module panel Consequently it is important to be very careful to update this field correctly when adding CP modules 12 1 2 Identifying an XP module ZE If it is an XP module it is a lot easier By pressing the thumbnail of the module it will start blinking both in the real life fuse box as well as the fuse box in Contool 2000xp 12 1 3 Moving a module After having identified a module it can be moved by pressing the surrounding grey panel which will highlight the selected panel as shown below The highlighted panel is the source panel and Dressing the surrounding grey panel on another module the destination panel will make the two panels swap place This can also be done with an empty slot If you accidentally press the wrong source module simply press the module again 21 From the top left corner to the bottom right corner 2 In order to swap it with itself MKJ 2011 02 25 page 38 of 53 XP11 0000000000 xP24 0020012508 1 xP24 0020012509 1 12 1 4 Replacing a broken module If yo
23. User manual for Contool 2000xp Version 1 1 release 2882 Guidelines on how to work with Contool 2000xp especially from a technical point of view Conson A S 25 02 2011 WE Lag Ce le Te te 6 A OARS e 0 te EE 7 21 BEST PIACIICS SHON EE 7 I MUON wcasencesceuanitnquten aun anuaaitnqutenanenencuaningdeuanunesntuasinedtenasenaneuaskngdenasenancuainadetaneneatuaninadetaneneaeuasinie 9 Se WE Viele TEE 9 SNOEN 10 4 1 Starting with an empty Droe 10 4 2 Importing a project from a previous version rrnrrrnrrnnrrvnrrnnrrnnerrnernnerrnernnernnernnrnnnnnnnnnnn 11 4 2 1 Exporting EE tied lle isa tages tel lel inl ages iene ele ek gestae eel 11 EIERE 11 4 3 Downloading data from Rue e TEE 11 4 4 Changing Bleu 12 5 Overall organization of the user mtertace 13 6 Detection of modules and XP sensors ccccccsecccseecceeeceuceceucccueeceuceseueeceeeseusesseeseeeessusensss 14 6 1 Placing detected modules 14 6 2 Placing detected XP sensors ccccscccscccscccececseecececececsecceeenseeceuecseeceeeceeeseeeseeeseeeneeenes 14 TNS 15 7 1 Themain panel 0 ccc ceccceccceeeceeeceeeceeeceeeceeecseessuecseesaeeceeeseeeseeeceueseeeseeeseeeseeeseeeneeeseeenas 15 7 1 1 Drag el OMONO le 15 DM HOVONNO EE 15 TE WTEC IG ICING REE 15 Polak te an E ele ao EE E 15 Lto Drawing EEE 16 Fee NG AGHON e EEE E EE 16 7 2 1 FIOM elt et 16 Teese FOO ET Blo 18 2 SSN 18 re PM 19 8 Floor plan Programming state nnannannnnnannannnn
24. XP 2606A MKJ 2011 02 25 page 26 of 53 The preferred way is to simply use a B variant of an XP sensor or XP 28 sensor which holds both the needed eye as well as the module functionality 8 3 4 UHF In Concept 2000 UHF integration is possible through the CP 70C module In Concept 2000xp UHF integration is very similar through the XP 70C module Both of these modules are programmed using Conbeam XP78 8 3 5 IR The IR integration is from a sensor module point of view very similar to the B amp O integration In Concept 2000 IR integration is possible through an IR eye in a sensor and a CP 70A module In Concept 2000xp this is still possible all though the module to use is called XP 70C Both of these modules are programmed using Conbeam XP 78 The preferred way is to simply use the A variant of an XP sensor or XP 28 sensor which holds both the needed eye as well as the module functionality 8 3 6 Timer There is no actual real life sensor available for the timer type due to the fact that it only consists of a module But since everything programmable in Contool 2000xp must be accessed through a unit on the floor plan a virtual sensor for 70D is added Like B amp O UHF and IR both a CP 70D and a XP 70D modules exist and both are programmed using Conbeam XP78 8 3 7 CP programming XP20 The Concept 2000 general way to program most functionality by placing a sensor and connecting this sensor to a CP20 module is still sup
25. XPOS 5703513054731 1 15 32 0 00 0 00 15 32 15 32 15 32 XP 2606 5703513056513 2 0 00 0 00 0 00 0 00 0 00 0 00 XP24 Lamp CN 0000000000000 8 0 00 0 00 0 00 0 00 0 00 0 00 XP31 Lamp dim 0000000000000 1 0 00 0 00 0 00 0 00 0 00 0 00 XP33 Lamp dim 0000000000000 3 0 00 0 00 0 00 0 00 0 00 0 00 Discount 0 00 Sub total 1 467 87 4 98 9 97 1 972 85 1 972 85 1 972 85 VAT 493 21 Total 2 466 07 13 2 2 Price lists The pricing is stored in price lists which also are selected in the Settings menu There are two separate price lists e Conson price list e Individual price list The Conson price list holds all prices for the Contool 2000xp while the Individual price list holds all prices for the custom units All price lists are located two places in the file structure at a global application scope and at project scope gt There are several reasons for this redundancy e A global pricelist is needed to be able to equal prices across projects e A project pricelist is needed in order to successfully export a project to another computer and still keep individual prices See section 3 1 for an in depth description of the project files and how to move a project to another computer When a project is created the selected Conson pricelist is copied to the project folder as the project pricelist By default a global pricelist
26. ctor to invoke functions on your fan right click the lamp and choose Actor Programming Now choose the actor Fan that should be controlled with respect to the bathroom light This will give you the usual programming dialog Functions for actor Bathroom Fan d Actor Bathroom Fan Output 1 Member of All on Push panel feedback Member of All oft SC ch Function Parameter Invert E Bathroom Fan Eer ge e E Module P24 Switch off time vw 10min v Function Parameter Invert f On After 2 min Switch off time 10min 11 1 3 Invert function You must have access to the invert function to program the fan so make sure the Invert function is checked in the Settings menu MKJ 2011 02 25 page 32 of 53 Auto report events come in two flavours A make event when the actor switches on and a break event when the actor switches off The Invert checkbox lets you choose which event should invoke this particular function If the Invert checkbox is checked the break event is used to invoke the function if unchecked the make is used this is the normal situation To turn on the fan the On After function is used with a time parameter specifying the delay from the bathroom light turns on to the fan is turned on To turn off the fan the Off function is used with a time parameter specifying how long time the fan should run after the bathr
27. e Invoice no Terms of Payment j The unit list marked in a green square is placed in the middle of the quotation and will be described in the following section MKJ 2011 02 25 page 47 of 53 13 2 Unit list The inline tab Unit list management is mainly used to provide a full view of the economic aspect of the project All units added at the floor plan and the fuse box tabs are automatically added to the unit list 13 2 1 Discount The column marked in a green square is editable except the last row which is an auto calculated field This column makes it possible to give a specific discount to any unit on the list or a total discount at the second last row In order to hide the discount fields as well as the cost price discount profit and one of the subtotals go to the Settings menu and select the Hide calculation in quotation menu item nit name misc Price apiece nit name pricelist Price apiece CP11 11 00 Unit name No Count Costprice api Discount apie Profit apiece Price apiece Sub total Discount Sub total XP11 5703513054861 1 99 66 4 98 9 97 104 64 104 64 104 64 XP130 5703513055967 1 221 21 0 00 0 00 221 21 221 21 221 21 XP33UNI 703513058975 1 265 84 0 00 0 00 265 84 265 84 265 84 XP31UNI 5703513057749 1 365 84 0 00 0 00 365 84 365 84 365 84 XP24 5703513059071 2 500 00 0 00 0 00 500 00 1 000 00 1 000 00
28. e easiest to have the web server installed on the same computer as Contool 2000xp but if this is inconvenient there are workarounds e Third party tools can map an ftp connection to a remote server as a drive letter e Third party tools can auto copy files from a local folder to a remote server The update button generates new wap files on the specified server file path And checking auto upload makes Contool 2000xp handle this operation automatically whenever events occurs which facilitates changes in these files The select sensors buttons makes it possible to select which sensors should be included in the wap functionality By default any new sensor is not part of this functionality 16 1 3 Html setup This section is nearly identical to the wap setup and to avoid confusion only the differences will be pointed out The server URL is still the URL to access your web server e g mydomain com conson www The server file path should be different from the wap setup It could for instance be C inetoub wwwroot conson www When updating the www files a few static images are copied to server file path images folder only on first update and an image of the current floor plans are dynamically created and copied on each update to server file path images floorplans The html file contains a WebClip Bookmark which can be used to easily create a link on the home screen of a iPhone iPad On Wind
29. e modules Notice that downloading data can only be done in a blank project with no actor or sensors added to the floor plan Enough data is stored in the XP modules sensors to automatically restore a project while only the basic data is stored at the CP modules The table below shows exactly which data is restored from the two different types The action tables contain the programmed functions while the setup data holds the direct programming The coordinates naming and connected are also known as Contool data The naming and connected actors are not stored in the CP modules but at the end of the download a wizard guides you through entering this information for the CP units As the table shows not all data are available e Naming of the units the push panels on the sensors and the output of the modules are available for the new Concept 2000xp units but only at a maximum length of 24 characters e Only the first push panel at any channel at an XP28 will be restored e The floor plan image will not be restored Even though the units are placed on their previous coordinates the background image is not present Yet it is possible to upload a backup of the image which will replace the default image e The restored units will be part of the quotation but any discount extra added units etc will not be restored e The project settings and the name of the project will not be restored eit
30. e process it is handled whether Design tools the units are rotated correctly Both the timestamp and the rotation are done by Floorplans pressing push panel no 2 and 3 for 5 Floorplan links Detect XP sensors seconds as illustrated below The sensor will start blinking once the process is complete i Start listening f Detect XP sensors After having pressed all XP sensors throughout the installation the list in Contool 2000xp will be sorted by the received timestamp The final step is to drag the sensor from the list to the floor plan In order to avoid accidentally dragging a wrong sensor it is only possible to drag the sensor at the top of the list As a best practice you should have Contool 2000xp with you on a laptop with a wireless connection as you walk through the installation This will enable you to verify that each pressed button indeed is being correctly time stamped and thus you will not end up with one or more not time stamped buttons at the end of your tour around the installation If a wireless connection is not available it is advisable to split the tour of the installation into minor bits S like one room at a time and place the time JJ N stamped buttons after each part of the tour XP25xx is shown to the left and XP26xx is shown to the right MKJ 2011 02 25 page 19 of 53 If the sensor is dragged on top of another sensor a dialog will be displayed enabling the transfer of the serial number Conse
31. el at a pre defined and perhaps recurring point in time The timers dialog is shown below where you will notice that it consists of four sections explained below in detail 15 1 Timer description A short description of the timer function displayed at the list underneath the dialog 15 2 Timer action and time trigger Used to specify the time of day when the timer should be executed and to select which action to trigger The action is pointed out by selecting a floor plan a sensor on the floor plan a push panel on the sensor and finally whether to push release or toggle the button Specify timer New selected timer Timer description Timer action and time trigger Hour Minute Second Sensor button 16 v o v foo v Floorplan 1 v Button name Button mode XP 2506 L1 v Go Channel 0 vi Toggle vi Repeat Daily Weekly Monthly Yearly For each 1 day s Timer repetition settings Start 11 July v 2010 v No end date End after occurence s End on Save timer Cancel 15 3 Repeat If you are familiar with the calendar function in Outlook you should find it easy to use since the functionality is displayed in a similar manner Basically each tab offers you functionality to repeat the timer on a daily weekly monthly or yearly basis 15 4 Timer repetition settings This part should also look familiar to user of the calendar in Outlook This section lets you select the start date of t
32. er details 2 Enable toggle This is used to enable disable the possibly to toggle the actor directly from usage state or the dialog itself See 9 1 1 for further details 3 Enable light level only available if the actor is connected to a XP31 or XP33 This is used to enable disable the possibly to set the light level directly from the dialog itself 8 1 5 Right click menu Actor programming Selecting the Actor programming from the right click menu of an XP actor will set the floor plan in Actor programming state which is shown by marking the actor invoker with an orange circle and prompting the user to select a second actor invokee The process is similar to selecting a push panel on a sensor invoker and subsequently selecting an actor invokee This is due to the fact that the new Concept 2000xp enables the actors to fire events on make and break and this event can be used to trigger events on other actors Consequenily when selecting the second actor invokee the regular programming dialog will be shown To exit the Actor programming state press the ESC key on the keyboard For at complete example on how to utilize actor programming see 11 1 8 1 6 Right click menu Setup alert The menu item Setup alert opens the dialog below Through the dialog it is possible to have Contool 2000xp sent out an e mail when a certain actor is turned on off e g if the outlet at the freezer is turned
33. ere are three identical ways that Contool 2000xp can detect modules and XP sensors 1 By simply starting the application in online mode by not checking the offline mode checkbox at the start up screen 2 By navigating to the fuse box tab and selecting Detect XP in the panel to the left 3 By navigating to the floor plans tab and selecting Detect XP in the panel to the left If starting the application in online mode all modules and sensors will be detected during start up but it is also possible to detect newly added units after the project is loaded 6 1 Placing detected modules All detected modules will automatically be added to the fuse box at the first vacant slot from the top left corner Since the modules will respond in a random order during detection they must manually be replaced afterwards See 12 1 for further detail 6 2 Placing detected XP sensors Unlike the modules the detected XP sensors are not automatically placed Instead they are listed in floor plan in design state in the Detect XP sensors tab See 7 2 4 for further detail MKJ 2011 02 25 page 14 of 53 7 Floor plan Design state The floor plan tab is the most comprehensive part of Contool 2000xp The action panel consists of three inline tabs e Design state e Programming state e Usage state Together they form a workflow for setting up an installation The first part of this workflow is the design state used to add all needed units a
34. he appropriate driver in a subfolder 7 XP20 XP70A XP70B XP70C or XP70D MKJ 2011 02 25 page 39 of 53 matching your operating system Please refer to the installation guides in these folders on how to install the driver Once the driver is installed all you need to do in order to detect the COM port is to press the Detect button which is located in the upload and download dialog displayed after having pressed either of the two buttons The detected COM port will be entered in the text field by the application If you know the COM port you may also enter the information yourself instead of pressing the detect button 12 2 2 Selecting data to upload Pressing the Upload button will display a dialog Programmable units nd i I xP130 and XP78 containing a tree view of all programmable units af E130 an in the project 0000000000 1 XP20 Fusebox 1 pos 2 2 XP130 0020016888 1 XP31BCU Fusebox 1 pos 1 3 0020012444 1 XP33UNI Fusebox 1 pos 1 4 0020012508 1 XP24 Fusebox 1 pos 1 5 0020012509 1 XP24 Fusebox 1 pos 2 1 0020012504 XP 2606 Floorplan 1 t _ 0020012497 XP 2606 Floorplan 1 The tree view is organized in two sub trees e XP78 sp e XP130 The XP78 sub tree is only present if any units requiring upload through the Conbeam are present and has non conflicting module Conbeam upload method 1rConbeam COM port numbers Module Conkey
35. he start menu neither in the control panel If you want to uninstall the application simply delete the folder where you installed the programme 3 1 Project files All projects in Contool 2000xp have a unique name which makes it easy to identify a project and which is also used to organize the project files Creating a new project in Contool also creates a new folder located at installation directory Projects project name This is useful when moving the application from one computer to another simply copy the complete project folder Make sure that the revision number of the destination installation of Contool 2000xp is identical with the source installation This can be verified by looking at the installation directory or in the Help menu About dialog MKJ 2011 02 25 page 9 of 53 4 Starting a project Start Contool 2000xp by clicking the exe file named Contool2000XP with the symbol This brings up the login screen with a list of projects to the left Initially this list will be empty but when it is populated selecting a project to the left will display detailed information in the fields to the right Contool2000XP Files Settings Help Project name Installer lt onson Elektronik A S Installer contact info 45 97323600 info conson com XP130 address and port 192 168 1 17 10001 Not Connected No project loaded 4 1 Starting with an empty project Start by pressing the Create new but
36. he timer as well as the end date if the timer is recurring 7 push followed by release MKJ 2011 02 25 page 51 of 53 16 Web service In order to take advantage of the web service in Contool 2000xp you must have access to a web server and the following description rests on the assumption that you have such access and possess basic knowledge on how to operate a web server Contool 2000xp contains a Web service in html and wap format Both of these offer an interface to operate the functions programmed through Contool 2000xp The wap format is pure text based while the html version contains both text and images Notice that the web service is fully functional but it is currently limited to only display Sesam push buttons 16 1 Setting up the Web service The following description is a generic description which does not deal with differences in operating system nor network hardware The image below illustrates a setup similar to the example in the following section Web service Global host or IP address _ Global port 87 110 120 130 9090 Mobile phone light control service enabled Server URL mydomain comfconsonfwap Kr Server file path c finetpub wwwroot conson wap mm Auto upload Select sensors Browser light control service enabled _ Enable HTTP IP webcam links in browser d Server URL mydomain comfconsonfwww WWW gt Server file path fm c finetpubjunnsrootfconsonfunvn TTT Important
37. hen a push panel is programmed to affect one or more actors a connection line will be shown between the sensor and the actor actors and all the units will be circled lf a programmed sensor is selected all the units affected by the sensor will have their connection lines displayed When hovering or selecting a push panel only the units affected by that push panel will have their connection line displayed Connection lines are shown in programming and usage state if the menu item Show connection lines is selected 10 1 4 Show info panels When selected the Show info panels will display a panel with text on a grey background The information on the panel is always displayed when a unit is hovered on the floor plan image to the left 5 But the content of the info panel will vary depending on the E SEN following e Any unit will display its name in any state MKJ 2011 02 25 page 30 of 53 o Indesign and programming state actors will furthermore display details regarding their connected module o Indesign and programming state sensors will display their placement text and XP sensors will furthermore display their serial and link number e fa push panel on the action panel to the right is selected the info panel will besides the above listed information display details regarding the programmed functions from the selected push panel This is the case in both programming and usage state 10 1 5 Fire on select in programming sta
38. her Notice that all settings in the Settings menu are global for the entire application and hence not project related When starting a blank project all XP modules and sensors will be detected This is fine as long as no sensors or actors are added to the floor plan MKJ 2011 02 25 page 42 of 53 Naming max length of 24 Floor plan image EE Quotation Project settings etup data Connected actors sensors D Q Ben O oe ken C O GA BS OO D 2 O O O Action tables NN kisses KN ER EI EN EN eme J Jolo Pressing the Download button will bring up a dialog with the option to download in three different modes e Tree e CP Interval e CP anonymous 12 3 1 The tree download mode The tree download mode consists of a tree view which mgeet ue GC HE is somewhat similar to the tree view found in the e i f Selection mode Tree CP interval CP anonomous upload dialog First of all it also holds two sub trees TT XP130 and xP78 XP78 and XP130 en a V 0000000000 5 XP20 Fusebox 1 pos 2 2 XP130 But in the download dialog the units are grouped in F xP31BCU i 0020016888 1 XP31BCU Fusebox 1 pos 1 4 sub trees by type And moving the mouse over a XP 3 E xP 2606 _ 0020012504 XP 2606 sensor does not mark its location on the floor plan g E 0020012497 XP 2606 e XP33UNI 0020012444 1 XP33UNI Fusebox 1 pos 1 3 i WI
39. hout the entire application e Atthe top a menu is located o Files gives access to functionality like save export import and close o Settings will be described in detail where they apply o Help contains a link to documentation etc e At the left marked in red a series of tabs are located which contains the main panel of Contool 2000xp o Floor plans holds blueprints and placed units Fuse box holds fuse boxes and upload download functionality Graphs display data from the modules Beta version Quotations contains prices unit lists and a simple invoice system Documentation automatically created from data in floor plans and fuse box Timers provides functionality to trigger actions based on setup rules O O O O o Web service gives access to setup web access to Contool2000xp e At the right marked in green an action panel associated with the selected tab from the right side is located Not all tabs have an action panel Contool2000XP Default created project Fies Settings Help Floorplans Fusebox L Graphs Quotations Documentation Offline mode No project changes MKJ 2011 02 25 Design state Programming state Usage state Design tools Floorplans Floorplan Floor Unit list Unit list quotation Unit name Count Price apie Sub total Discount Sub total Total Le H 8 Unit list paid Unit name Count page 13 of 53 6 Detection of modules and XP sensors Th
40. ilable with each eye After having selected a key combination continue programming by selecting an actor like with any other sensor 11 3 2 Operating the real life BEO4 remote control To control the lights the BEO4 must be in the LIGHT mode To enter this mode press the LIGHT button Subsequently operate the remote just like when programming the remote in Contool 2000xp To summarize the following key combinations are available 18 The following units contain an BEO4 eye XP2506B XP2606B XP28B 19 65 for channel group 0 since it also decodes the 5 symbol keys MKJ 2011 02 25 page 36 of 53 e LIGHT SYMBOL KEY e LIGHT NUMERIC KEY S ACTION lt is not necessary to press the LIGHT key if the remote is already in light mode And when operating functions on the numeric key 0 this key can be left out since it is the default Consequently operating consecutive function on key 0 can be done by only pressing action keys 11 3 3 Programming example Say you have 3 lights in a living room controlled by the Conson XP33 3 channel light dimmer The lights are numbered 1 2 3 and you want to control the lights both individually and as a group using the A for light up v for light down and GO for off The group functions are added to key group 0 In Contool programming press 0 followed by A on the BEO image to the right and add the increase level function to each of the 3 lights Then press 0 followed by
41. itchlink Module Configuration CP20 SW2 1 1 9 Sensor Selection Added Sensors Sensors CP 2505 CP 2501 CP 2502 CP 25026 Sensor Configuration Sensor name cP 2505 Sensor placement Invert Current button Go Short long EE EE Channel Group on off PPT ft ft ESCH AND no 1 oe WS HE WOR Relax anono2 ok anono3 amp k aper kJ anonoS k aNDno6 kJ op kl apres k pon 5 per 6 Dee me Modulen Module Function Output CP24 Set light lev en Pafen en Waat r Want EZE ECH EECHER The part marked in a yellow square holds all available sensor types at the right and available sensor in the project at the left The marked sensor is shown at the bottom right corner CP20 XP20 CP XP70A D MKJ 2011 02 25 page 45 of 53 Selecting a push panel works just like it does at the floor plan by enabling the text fields but also the option to select which channel from the left side to connect to the selected push panel marked in a red square Connect all inputs from all link modules to push panels like described above before pressing the Finish button Doing so will close the wizard and place all new actors on the floor plan to the left and all new sensors to the right The actors will be organized in the order their connected modules are placed at the fuse box one row per module and subsequently by which
42. l k 1 2 3 4 The middle section of the dialog shows the direct programming In this case the mode normal and no FEE functions for the 4 outputs Output Actor ri Name 1 CP24 Lamp ON OFF The lower section named Actor configuration enables the user to select a connected actor for each output In the yellow square red stars mark which outputs should have an actor connected based on the downloaded functions in the action table In this case all four outputs need an actor and the first 2 3 4 The sum is 3 and the first module is currently shown MKJ 2011 02 25 page 44 of 53 output has already had a CP24 Lamp on off connected At the right column the actor can be name By default it is name the same as the actor type Remember to press enter to exit and save the name when renaming When all actor modules have had the actors connected to all red star marked outputs press the Next button at the bottom right corner to go to the second step of the wizard The second step of the wizard deals with the link modules Just like the first step it shows the type link number and amount in the top left corner The Prev and Next buttons are used to navigate through the modules and below is the direct programming The bottom left corner marked in a green square holds the eight inputs and their functions A red number indicates that this input is not yet connected with a push panel Sw
43. le directly on the claps minus to a clap make sure to tighten the screw on the clap Otherwise you might end up with a loose connection e When programming or firmware updating a module or sensor switch all data in the module is overwritten e Save your project regularly using the save as functionality and provide a new name each time like my project 1 units placed and my project 2 XP24 programmed This will enable you to go back in time to any critical point in your installation e Even though all naming is stored in the project and backed up in the XP modules and sensors with a few limitations for restoring a project it is still important to document the installation properly MKJ 2011 02 25 page 8 of 53 3 Installation Contool 2000xp is distributed as a single installation file which currently only runs on Windows It is a simple installation which merely unpacks its content at the preferred installation path By default this is at the desktop in a folder named Concept2000xp rev number where number is replaced by the revision number This happens in a wizard 1 Select Run when warned by Windows about the installation 2 Accept the license agreement 3 Select a different installation path if needed and press install 4 Close the installation wizard when all files have been unpacked Notice that since the installation wizard merely unpacks the files the application will not show up in t
44. lected the Invert function will become visible at i l Se l Conson price list the programming dialog offering the possibility to invert a Individual price list gt programmed function See 11 1 3 for further detail cn 10 1 2 Automatic connection Ge e Automatic connection Maximize on start When selected the Automatic connection makes it faster V Show connection lines to place and program units since the user is no longer d Show info panels prompted to make some of the detailed decisions Fire on select in programming state vd Fire on select in usage state In design state the user is not prompted to choose at which Hide calculation in quotation output at which module to connect an actor if placing an Center window 1024x768 pixels actor Contool 2000xp will automatically choose the first Change licence vacant output at the first suitable module and if no module is present a new module will automatically be added The same kind of logic applies when placing a unit with a B amp O eye or an IR eye if Automatic connection is selected Contool 2000xp will not prompt you to select the channel on which the eye should look for data In programming state the user is not prompted to choose at which input at which CP20 XP20 module to connect a push panel to if programming a CP sensor In order to have full control over these decisions deselect the Automatic connection 10 1 3 Show connection lines W
45. n collection report list of the associated fuse boxes 14 2 Fuse box report The fuse box report consists of a graphical overview of the modules present on each fuse box and their placement Underneath the graphical overview is a textual overview with all the modules listed in the same order as graphical overview Each module is listed with its type coordinates serial number and a list of the units connected with it s in and outputs 14 3 Sensor report The sensor report lists all sensors It shows which address each input transmits and a detailed list of the content of each associated function collection 14 4 Actor report The actors report lists all actors It shows its connected module and the sensors affecting the actor as well as detailed information about which function are setup for each actor 14 5 Function collection report The function collection report lists all functions which are grouped by the address by which they are triggered This is referred to as a function collection Each is listed with details regarding the address complete content of the function collection which sensors triggering it and which actors are affected by it 7 by link and channel number MKJ 2011 02 25 page 50 of 53 15 Timers Timers can be created to trigger events at a certain point in time Timers operate on top of programmed functionality from the floor plan A simply way to explain the timer module is to think of ita pressing a push pan
46. n panel to the left 2 Enter placement and rename sensor Notice that the sensor is already named so renaming it is not mandatory 3 Select a pushbutton on the zoomed sensor CP70C01 CP70C05 CP70C08 and CP70C16 MKJ 2011 02 25 page 24 of 53 4 Rename pushbutton Notice that the pushbuttons are already named so renaming them is not mandatory 5 Select programming method is strictly soeaking not part of the shortest path but it is the most common path since most sensors offers more than one programming methods But since a few sensors only have one programming method the step is left out in these cases 6 Select actor on the floor plan by left clicking on an actor at the main panel which opens up a dialog 7 Add the preferred function in dialog and press Ok button 8 2 2 Alternative workflow Programming multiple push panels at the same time It is possible to select multiple push panels in any workflow by holding down the Ctrl key at the keyboard and select several push panels Release the Cirl key after having selected the preferred push panels and before proceeding to the step Rename pushbutton If pushbuttons with conflicting programming have been selected the following dialog will appear with the following options when releasing the Ctrl key Conflict in programming in selected push panels Y There is conflicting programming in the selected push panels How do you want to solve the conflict Copy prog
47. n the modules sensors by downloading data from the modules The new units from Concept 2000xp contain enough data to automatically restore a project while the old units from Concept 2000 only contain the most critical data A wizard is provided when downloading data from the old modules in order to guide the user to fill in the missing pieces The process is described in detail in 12 3 MKJ 2011 02 25 page 11 of 53 4 4 Changing licence When starting Contool for the first time all functionality will be present But it is possible to restrict this functionality to the suit the needs of a typical end user This is done in the Settings menu by clicking the Change licence menu item Doing so will display a dialog requesting a global password needed to switch to the limited end user licence In order to switch back to the full licence use the same menu item and the same global password This password is available on request Notice that the license settings affects the installation of Contool and not the project In other words the complete Contool installation will have its licence changed but it will still be possible to move a project to another full installation and thus have full functionality in that and any other project MKJ 2011 02 25 page 12 of 53 5 Overall organization of the user interface When the project is loaded the below user interface is shown The interface has the same basic look and feel throug
48. n the quotation and these units are not available for programming Furthermore notice that all manually added units are kept at the bottom of the quotation Even if an automatically added XP11 is present in the quotation a manually added XP11 will still be kept in its own record at the bottom As shown in section 13 1 it is possible to print the unit list which will respect the hide unhide calculation setting 13 2 4 Managing units The Unit management button at the right opens the dialog below The upper part marked in a green square updates the VAT and currency symbol of both the Conson pricelist as well as the Individual pricelist The lower part consists of two inline tabs which update the Conson pricelist and Individual pricelist respectively The controls at the lower part marked in a red Square only interacts with the pricelist on the selected tab Pressing the Copy price list button will open save as like dialog and the new pricelist will automatically be selected In order to copy both pricelists this action must be performed on both tabs 13 3 Invoice Unit overview Pricelist data VAT 25 0 Currency symbol Conson units Own units Price list Test1539 Unit name Cost price Discount Profit CP11 11 00 5 00 10 00 CP20 20 00 10 00 10 00 CP24 124 00 0 00 0 00 CP31BC 31 11 0 00 0 00 CP31DD 31 22 10 00 10 00 CP31LR 31 33 10 00 0 00 CP31CR 31 34 10 00 10 00 CP33 133 00 10 00 10 00 X
49. nd connect these Consequently the target audience is technicians 7 1 The main panel The main panel to the left displays when fully populated a customizable background like a blueprint image with Conson units placed on top and how they are connected 7 1 1 Drag and drop Later on it will be described in detail how to add units to the main panel For now let E HE us assume that units are p d present at the main panel j In design state these can PN Ke be dragged anywhere on the background making it i possible to create an intuitive model of a real life installation 7 1 2 Hovering When holding the mouse over any type of unit an info panel is displayed with detailed information regarding the unit See 10 1 4 for further detail 7 1 3 Left clicking Left clicking has an associated action in the following scenarios e When placing units when these stick to the mouse cursor See 7 2 3 e When adding or operating floor plan links See 7 2 2 7 1 4 Right clicking Right clicking has associated action on all units by displaying their right click menu The content of the menu depends on the unit type e Delete is available for all unit types MKJ 2011 02 25 page 15 of 53 e Is WAP enabled is available for all sensors This will toggle whether the sensor is part of the WAP access By default no sensors are part of the WAP access See 16 1 2 for further detail e Blink is available for all XP sensors
50. nnnnnnnnnnnnnnnrnnrnnrnnrnnrsnrnnrnnrnnrnrrnnrnnrnrrnrrnrrnnnnne 21 EENHEETEN 21 8 1 1 KOMEN 0 EE te ple tae tagea tried lle isa tafe tel bela ini ages iene ele nek ges ie eel 21 Ce e KING EEE EEE 21 PLS 6 ge Te ele Te ME 21 8 1 4 Right click menu Actor console ccccccceeeceeeeeeeeeeeceeeeeeeseeeeeeeeeeseeeteeeseeeseeesenees 22 8 1 5 Right click menu Actor Drogrammmg 22 MKJ 2011 02 25 page 2 of 53 8 1 6 Right click menu Setup aert 22 8 1 7 Right click menu Configure webcam ccceccccseeeeceeeeeeeeeeceeeesaeeeesaeeesseesseeesaaees 23 8 18 Rightcliek MENU CONNGQUIC a iinan desen deed e 23 8 1 9 Right click menu Connect eye 23 8 1 10 Right click menu Upload single mogule cece eee cece eee eee ee ea tessa essa eeeseeeeeaaees 23 8 2 The action ANER pda 23 8 2 1 General WOrkflow cccccccccsecceceeeeceeeeeseeeseecesseeeeseeeessaeeeseeeeseeeeseeeeseeeessneeeseeesaees 24 8 2 2 Alternative workflow Programming multiple push panels at the same time 25 8 2 3 Alternative workflow Programming remotes through eves 25 8 2 4 Alternative workflow Programming by selecting module and channel 0 25 Er MENN 26 8 3 1 AP SONGO 26 DP 26 e E BEO ee E E a E 26 5 UAP EEE EEE EE EE 27 Nr 27 SO MMM E 27 8 3 7 CP programming Gb 0 27 9 Floor plan Usage S11 EEE 28 RE as E DANE EE EE 28 9 1 1 Ree Tele RE EN 28 JG EEG Re 8 0 ee 016 RENEE EEE 28 ES AO tee EE eee ere ee eee
51. nrennanennnnsnnnnnennnsennnsennnsen 40 12 2 3 Uploading data XP130 and SI 41 122 Upad aA APTO eea E a 41 12 3 Downloading data from modules 42 12 3 1 The tree download mode 43 22 Baise maa gic atc 191012 gt EE 43 12 3 3 The CP anonymous mode 43 12 3 4 Downloading data XP130 cccccccccecceeeceeese cece eeseeeseeeseeeseeeseeeseeseeeseeeseeeneeeneeenes 44 12 3 5 Downloading data XP78 with wzard 44 Io Vee OU WEE 47 to ATTEN 47 BE NN 48 BI BE iateiaueisendt iatessuesmuensteianeruesmuente 48 IE EEE le GTS S E 48 13 2 3 Adding and removing units to the quotation reernnrrnnnnnnrnrnnnnnnnnnnvrennnernnrrnrnrnennnnen 49 19324 Managing EE noted anto PA m EEEa E Raa aaia E Ema ai 49 MKJ 2011 02 25 page 4 of 53 BS SC VOICE saa EE E EE A 49 14 Documentation E 50 ee MANT oe e a eee anne er eee ere eer ne eee nee ne eee ere ere 50 t2 FEDO DO EE 50 4 En Ee gl le 50 aA ACOTO RE E 50 14 5 FONCHUONCOlSCtHON TODON eerie ANa a RETER RETETE 50 15 ME 51 Ta EIN 51 15 2 Timer action and time trigger cccseccceeeccececeececeeeccuceceucecseecsuseceueeseeessueeseeesseeessueensess 51 D Ni 51 15 4 MR rn Ee Et ie AE ln e EE 51 16 EE sa EEE EE ENE 52 16 1 Setting up the Web senice 52 Ea PJ 52 16 1 2 Wap setup E 53 1615 Flem er 53 MKJ 2011 02 25 page 5 of 53 1 Introduction Contool 2000xp is the successor of the old Contool application which was used to programme modules in the original CP series The ne
52. oom light is turned off This function must be triggered by the break event On the figure above you can see the entire programming of the fan Press Ok as usual when done and you will see a link between the bathroom light and the fan just as you would between a sensor and a lamp 11 1 4 A note on the Fan symbol and XP24 XP24P When designing floor plans the fan symbol uses an XP24 module If you want to run the fan from an XP24P module turn off Automatic Connection in the Settings menu You will then be able to connect the fan to either an XP24 or an XP24P 11 2 Curtain control In Contool you have some actor symbols used for controlling curtains and blinds In this section we will look at how they are used 11 2 1 Curtain actors In design state you find the motors for curtain control under the XP tab by pressing the motor button There are two standard AC motors using two relays from either an XP24 or an XP24P power registration The relay pairs 1 2 and 3 4 will be mutual exclusive with a dead time of 300ms The dead time can be changed using the Direct programming dialogue see illustration below in this section Furthermore there is one DC motor using four relays from an XP24 and finally a simple fan motor using one relay from an XP24 If you need XP24P for fan control disable automatic connection in the Settings menu 11 2 2 Programming Curtains We will describe programming curtains
53. or plans 3 Sensors actors used to add sensors and actors to the floor plans 4 Detect XP sensors used to add detected XP sensor to the floor plans The bottom part of the action panel in design state is occupied by the Unit list in the first three of the four tabs listed above The unit list simply displays all placed units sensors actors modules etc in the project By using the up and down arrows in the middle of the list is a possible to move units out of the quotation Design tools The remaining part of this section regarding NabachNpisencars the design state will focus on the Floorplans Sensors actors functionality on the four tabs listed above Floorplan Ee 7 2 1 Floor plans p Floor Floorplan 1 Apply Most of the controls on this tab speak for themselves but these controls used to select a new floor plan image are worth commenting further Sy Remove G Copy MKJ 2011 02 25 page 16 of 53 In Contool 2000xp it is possible to use professional blueprints your own customized background image or even room photos for each of the project floor Viewport height plans default 580 pixels For demo purposes Contool 2000xp is shipped with several blueprints as well as a photo of a B amp O equipped room These images will be used throughout the user manual but obviously each real life project should always use real life blueprints photos supplied by the end user Viewport width default 650 pixels
54. ownloading data XP130 The download process is fully automated for Concept 2000xp modules and sensors after having selected units and pressed the Ok button The downloaded data consists of action tables setup data and Contool data The action tables and the setup data are simply overwritten in the modules sensors in the project and together with the Contool data the programmed functions are made visual at the floor plan by restoring actors and sensors at their location alongside with restoring the naming of the units the push panels and the output input of the connected modules 12 3 5 Downloading data XP78 with wizard After having downloaded data through XP78 from either one of the three download modes Contool 2000xp only knows of the action tables and the setup data but not the Contool data since this is not available from the old modules In order to still make it possible to download data from the old modules a wizard has been created which takes the user through two steps Direct Link Module Configuration 1 Actor modules 2 Link modules The first step consists of all the actor modules which must have actors connected to their outputs The green square at the below illustration shows the type of the current module the module number and sum of downloaded actor modules The Prev and Next buttons just below the module image are used to navigate through the available actor modules Mode Norma
55. ows this can be found by running a command prompt and typing ipconfig followed by Enter MKJ 2011 02 25 page 53 of 53
56. per type are available One of these link numbers are reserved which leaves a maximum of 99 units of the same type For guidelines on how to program these sensors see section 11 for further details 8 3 1 XP sensor The sensors named XP 2506 and XP 2606 are XP sensors Both of them have variants with a B amp O eye named with a post fixed B or an IR eye named with a post fixed A An XP sensor holds both module type link number and channels numbers in itself as well as push panels and can be programmed without being dependant of any other units This is also the case with the A and B variants which have built in eyes 8 3 2 XP28 The sensors named XP 28 are XP 28 type sensors and like the XP sensors they come in A and B variants Even though the XP28 sensors are very closely related to the XP sensors there is one major difference XP28 sensors have no push panels Consequently push panels from non programmable sensors must be wired to an XP 28 sensor in order to operate it 8 3 3 B amp O In Concept 2000 B amp O integration is possible through a B amp O eye in a sensor and a CP 70B module In Concept 2000xp this is still possible all though the module to use is called XP 70B Both of these modules are programmed using Conbeam XP78 1 If the sensor is a CP sensor the responsibility to broadcast the telegram is actually the module which the sensor is connected to TT XP 2506B XP 2606B 12 XP 2506A
57. placing a unit by left clicking on the floor SSe SEE h plan a new unit of the same type sticks to the mouse cursor until ESC is pressed or the mouse cursor is moved outside the floor plan area Most actors require a connection to a module and some sensors require a connection to an eye Whether this connection is handled automatically by Contool 2000xp or handled manually by the user is set in the Settings menu by the Automatic connection option S http www gimp org downloads MKJ 2011 02 25 page 18 of 53 See the sections 8 and 11 for an in depth description of how to program units 2 4 Detect XP sensors The detect XP sensors tab replaces the unit list with a list of detected XP sensors If the list does not contain the expected count of units press the Detect XP sensors button to make Contool 2000xp try to re detect sensors The list contains information about serial number and module type in a random Time Serial Module Output Fusebo order but in order to place the sensors 0020012504XxP2606 D D 0 0 correctly on the floor plan it is importantto p020012497KP2606 P b 0 0 be able to have them displayed in a sorted order They can be sorted by pressing the start listening and walk around the installation in a fixed order pressing the push buttons on the way Each unit will when pressed send out a timestamp which the application will use to order the units In the sam
58. ported in Contool 2000xp The connection from the sensor to the module can now also be done with an XP 20 module 13 CP 2502B CP 2507B CP 2509 CP 2602B CP 2607B CP2609 14 CP 2502 CP 2507 CP 2602 CP 2607 MKJ 2011 02 25 page 27 of 53 9 Floor plan Usage state The usage state is the third and final state where all units have been placed connected and programmed The state merely contains functionality to operate the units Consequently its target audience is the end user 9 1 The main panel The main panel looks identical to the previous two states but the functionality differs 9 1 1 Left clicking It is possible to left click both sensors and actors e Left clicking a sensor brings up a zoom of the sensor at the action panel See 9 2 2 e Left clicking an actor toggles the actor if a toggle is available through a programmed function and if toggle is enabled see 8 1 4 9 1 2 Double clicking Double clicking a webcam will open a dialog displaying the webcam viewer 9 1 3 Actor feedback If the actor is set to send feedback operating a function in any way will change the icon of the actor to illustrate its state on or off 9 2 The action panel The action panel in usage state consists of the parts 1 Miscellaneous which enables the end user to open links to websites and locally installed programs and edit these links as well 2 Sensor which enables the end user to trigger programming in Contool 2000xp as if p
59. quently it is possible to setup a complete project off site go online at the site to transfer the serial numbers and finally upload the programming to the sensors and modules MKJ 2011 02 25 page 20 of 53 8 Floor plan Programming state The programming state enables programming the units placed in design state Consequently the target audience is technicians 8 1 The main panel The main panel to the left displays the units placed in design state and the programming as the programming of the units are created during this state 8 1 1 Hovering The exact same information is displayed in programming state as in design state when hovering See 7 1 2 8 1 2 Left clicking Left clicking has an associated action in the following scenarios 1 When clicking a sensor except remotes needing an eye This will display a zoom of the sensor at the action panel 2 When clicking a remote needing an eye This will prompt the user to select a compatible eye and making the selection easy by hiding all non compatible units 3 When clicking an empty coordinate on the floor plan This will exit the state entered at any of the two items above 8 1 3 Right clicking Similar to the design state right clicking any unit will display their right click menu and the content of the menu depends on the unit type e Program direct is available for all actors and all XP sensors e Update firmware is available for all XP actors and all XP sensors
60. ramming from first selected Go Delete programming i e Copy programming from first selected will delete any programming on all other push panels than the first selected and copy the programming from the first selected e Delete programming will delete the programming on all the selected push panels e Cancel will not have any impact besides clearing the selection Proceed with step Rename pushbutton unless having selected Delete programming 8 2 3 Alternative workflow Programming remotes through eyes This workflow applies for all remotes controls needing eyes to operate These remote controls are easy to spot since the action panel will display a message to select an eye after having selected an eye needing remote control Furthermore all non compatible units will be hidden making it easy to select a compatible eye at the main panel After having selected a compatible eye proceed with the general workflow at Enter placement and rename sensor 8 2 4 Alternative workflow Programming by selecting module and channel CP switches in manual connection mode or just CP switches through XP28 units need additional steps to complete their workflow After having selected a programming mode controls to select a CP XP20 or an XP28 will become available If selecting an XP28 this can be done in the dropdown list or by selecting the XP28 directly on the main panel Either a BeO4 or a CP79 If the remote is a BeO4 selec
61. ressing the physical push panel 9 2 1 Miscellaneous Contool 2000xp is shipping with language specific template functionality for the miscellaneous section in usage state AN o H A When creating a new project the template CH A for chosen language is copied to the a TV project GO hd Graphically the sections hold 3 x 6 buttons A where each of these buttons can control El one or more actions The default layout is shown below Miscellaneous 1 gt There are three ways to operate an actor 1 In usage state by left clicking the actor 2 In usage state by left clicking a push panel on the zoomed sensor in the action panel 3 In reallife by pushing a push panel on a physical sensor MKJ 2011 02 25 page 28 of 53 When left clicking one of the 18 controls one of the following will happen e If there is no action defined merely the message No functionality has been specified for this button will be displayed e If there is only one action defined this action will be initiated In revision 2670 the actions can be either opening a webpage or a locally installed programme from a URL e If there is more than one action defined a popup list will be displayed with all the actions Double click the wanted action When right clicking a control you will get the following options e Change icon used to change the icon by picking another image located on the computer This action is always available e Delete
62. s 3 4 Output 4 Toggle v 0 sec With this dialogue you can setup which functions to use for the direct input of the XP24 Besides that you can select mutual exclusion between the relays in pairs The Blinds checkboxes are described below 11 2 5 Controlling blinds Some curtains tilt the blinds when they are in the down most position In this case you can sometimes open the blinds by turning on the up direction of the motor in short pulses With XP24 this is done checking the Blinds box shown above When the blinds function is selected short pulses below 1 second will only switch the relay on for as long as the button is pressed In other words short presses below 1 second on the button will give you short pulses on the relay whereas pressing the button for longer than 1 second will leave the relay on when you release the button 11 3 B amp O This short guide describes how the Conson XP modules can be controlled from a Bang amp Olufsen BEO4 remote control 11 3 1 Programming in Contool 2000xp A B amp O remote needs at least one unit with an embedded eye to operate through Three different units can provide this e XP2506B e XP2606B 17 You only need to select one of the All off buttons for this programming even though you might have several All off buttons in your system This is because each button which has the All off programming method selected will send the exact same event It is done this way
63. so timestamp the detected XP sensors in Contool 2000xp and by keeping track of your route through the installation you will Know in which order to place the sensors By bringing a wireless connected notebook you will be able to easily verify that all sensors are being time stamped correctly and thus avoiding to accidently place them in an incorrect order at the floor plan 2 1 Best practice short list e Read the manual before you run into an accident e Make sure you have lights available at your installation e Your toolbox should contain work light wireless router tested before you leave for the work site an XP130 and a small working test project e Bring enough working sockets with cord and light bulb to enable you to have a light connected to all outlets you will be programming e A handy tool is to further bring a module and a switch that you are confident is working for testing purposes Mount the switch at your XP24 at clamp B C D E to make the switch run on its own Consonbus Mount the module at the Conbus as the last module on the Conbus The long bus The short bus MKJ 2011 02 25 page 7 of 53 e When programming a module it will power down and reboot So make sure to programme in accordance to the end users needs And remember that it is possible to programme a module at a time if you need to e All switches have unique serials which cannot be overwritten e When testing a modu
64. t one of the following eyes XP 2506B XP 2606B CP 2502B CP 2507B CP 2509 CP 2602B CP 2607B CP2609 If the remote is a CP70 select one of the following eyes XP 2506A XP 2606A CP 2502 CP 2507 CP 2602 CP 2607 MKJ 2011 02 25 page 25 of 53 Selecting the channel is last part of the step which is done by left clicking the preferred radio button Selecting the channel is not enabled if having selecting the programming mode All on or All off and a CP20 XP20 module due to the fact that this programming mode is set at fixed channels Finally notice that when selecting a channel which is already programmed through another connected sensor the existing programming will be displayed And changing the functionality will affect all sensors connected to that channel 8 3 The sensors Since the type of the sensor has such a great impact on how the work flow goes let us have a closer look the sensors The sensors can be categories based on differences in their functionality The ultimate responsibility of all sensors is to broadcast a telegram when activated which is a combination of their type a link number tied to the unit and a channel number tied to a push panel or similar This is important due to the fact that there are constraints on these combinations e Inthe Concept 2000 CP series a maximum of 4 different link numbers per type are available e Inthe Concept 2000xp XP series a maximum of 100 different link numbers
65. te By default when clicking a push panel in programming state the push panel is selected This setting can be used to change the default behaviour to fire the function instead making it work like the default setting in usage state 10 1 6 Fire on select in usage state In usage state the default setting is opposite the setting in programming state By default a function is fired by clicking a push panel but it can be changed to selecting the push panel instead This is useful for showing full details in info panels like described in 10 1 4 MKJ 2011 02 25 page 31 of 53 11 Programming examples for the XP series 11 1 Exhaust fan This short guide describes how a bathroom exhaust fan can be programmed with Contool A normal way to control a bathroom exhaust fan is to have it running on a timer delaying start and stop with respect to the bathroom light This is done in Contool using Auto report events actor programming and invert function 11 1 1 Auto Report Events Each actor can send out an event when the status of one of its outputs changes _ Contool Actor C This must be enabled in the Actor Console ZC Output 1 Output2 E Right click lamp choose Actor Console and check the Enable Auto Reporting flag You can only do this while online with the system v Enable Auto Reporting Status n a Enable Toggle 11 1 2 Actor Programming To use the auto report events from a lamp a
66. to save programming space in the modules All on operates in the same way MKJ 2011 02 25 page 35 of 53 e XP28B After having placed a BEO4 and at least one unit with an embedded eye select the BEO4 and afterwards select an eye This will display a zoom of the BEO4 at the action panel to the left The channel group configured at the eye determines which key combinations are available By default the channel group is set to 0 This can be reconfigured by right clicking the eye and selecting Configure Channel Available key group Symbol keys 5 combinations Green Yellow Blue Red e Stop Numeric keys 0 11 combined with action keys 60 combinations Wind gt gt Rewind lt lt Step up A Step down v O Numeric keys 12 23 combined with action keys 60 combinations Numeric keys 24 35 combined with action keys 60 combinations Numeric keys 36 47 combined with action keys 60 combinations Numeric keys 48 59 combined with action keys 60 combinations The symbol keys are operated by themselves like any other push panel ona sensor 4 5 6 Numeric keys can either be one or two digits combined by an action key The numeric first key will be marked in blue the second will be marked in green and the action key will be marked in red Consequently any numeric key combination is available in 5 variants and since a channel group decodes 12 numeric key combinations 60 functions are ava
67. ton which will bring up the Create new dialog Create new Project name Default created project User name Password The field Project name is mandatory while the user name and password are not mandatory If you choose to fill out these two fields you will be prompted to login before being able to start the project The most important fields to the left are the IP and port of the XP130 which you will be connecting through and the checkbox indicating whether to start in offline mode MKJ 2011 02 25 page 10 of 53 When starting a project Contool will even in offline mode try to start its web service by binding it to port 9090 Due to the fact that only one service can be bound to a port an error message will occur if trying to start a project in more than one instance of Contool The second started project will work just fine only the web service will not be operational Finally an XP130 only accepts one open connection so it is only possible to have one project in online mode accessing the same XP130 4 2 Importing a project from a previous version The save function in Contool is tied to the Contool release number Consequently you cannot load a project file from a previous version of Contool If you need to upgrade a project to a newer version of Contool use the Export Project to files and Import Project from files 4 2 1 Exporting files gt Contool2000XP Ud AE Settings Help To
68. u need to replace a broken module in a running installation this can easily be done by following these steps If the module is an XP module 1 Start the project in offline mode 2 Change the serial number at the top of the module like O020012508 to match the serial number of the new module 3 Save the project and disconnect Replace the module at the real life fuse box 5 Start the project in online mode In the start up process the new module will be detected but since it already exists on the fuse box due to that fact that the old module has just had its serial number updated 6 Upload data to the module It is only necessary to upload data to the newly replaced module m If the module is a CP module 1 Replace the module at the real life fuse box 2 Start the project in online mode 3 Upload data to the module It is only necessary to upload data to the newly replaced module 12 2 Uploading data to modules The upload section is placed at the bottom of the action panel just above the download section The upload section is responsible for transferring data from Contool 2000xp to the modules and the XP sensors 12 2 1 Installing and detecting the Conbeam XP78 If you need to transfer data to modules from the old Concept 2000 series or the newer XP variants you will need to first install the Conbeam driver which is shipped with Contool 2000xp Go to the installation folder ConbeamUSBDriver and locate t
69. uently we have summed up the most important key points in a quick start guide When planning an installation it is advisable to assign a fuse for each XP11 and perhaps even an HPFI relay if it is economically feasible The default IP address is 192 168 1 17 when connecting to the XP130 Best practice is to use a notebook with a wireless connection enabling you to move freely around the installation with Contool 2000xp at hand All XP modules and XP sensor will be automatically detected when connecting to XP130 in online mode The modules will be placed on the fuse box tab in a random order while the XP sensor will be listed on the floor plan tab on the inline tab Detect XP sensors in Design state Verify that the number of XP modules and XP sensors match the expected number in the installation If this is the case you can assume that all modules and sensors are wired up correctly since they all respond If the numbers do not match try to manually detect them as described in section 6 If you are still missing modules and or sensors you should start to verify that you have connected everything correctly The XP sensors must be dragged to the floor plan before they become operational in Contool 2000xp Upload a blueprint image or similar to the floor plan to make the most intuitive installation Before placing the XP sensors you need to activate each sensor by pressing the two upper buttons see section 7 2 4 Doing so will al
70. uploading to multiple units from the Fusebox Only difference is the fact that there will always only be uploaded one single module when triggered from Upload single module menu item 8 2 The action panel In order to start working with the action panel the first step is to select a sensor by left clicking on it on the main panel to the left Doing so makes displays a zoom of the selected sensor MKJ 2011 02 25 page 23 of 53 How to process from here depends mainly on the type of the selected sensor and settings in the Settings menu The various paths on how to complete the programming are shown in the below work flow chart where all paths start by selecting a sensor Select a sensor y Enter placement and rename sensor y Select a pushbutton gt Rename pushbutton y Select programming method y Select actor on floor plan Add preferred function in dialog and press Ok 8 2 1 General workflow This workflow applies to all XP switches CP switches in automatic connection mode CP70C remotes and the virtual 70D sensor The general workflow is displayed as the series of light blue squares and represents the shortest path Since every single step except the Select a pushbutton is part of any other path each step will be explained in details below 1 Select a sensor from the mai
71. w Contool 2000xp is an application offering the complete set of tools needed to work with the new Concept 2000xp also referred to as the XP series Conson is renowned for its backwards compatibility and this quality persists in Contool 2000xp since it also fully supports the original CP series In short Contool 2000xp supports the complete process when working with a new installation projecting an installation with the end user making a quotation programming and documenting an installation is all integrated in the intuitive workflow Even though this user manual focuses on the use of Contool 2000xp from a technical point of view it is extremely important to point out that the purpose of Contool 2000xp is to make a piece of software which is easy to use for non technicians The end user is in focus due to the fact that it all adds up to provide a user friendly view of the installation on a blueprint which can be directly operated by the end user Even though Contool2000xp is now released in version 1 0 we will continuously be adding more features and will appreciate any feedback you may have We cannot guarantee that your feedback will be handled right away but we do guarantee that all remarks will be recorded and taken into consideration MKJ 2011 02 25 page 6 of 53 2 Quick start quide We strongly advise you to read the complete manual carefully before creating your first project but we also realize that sometimes time is short Conseq
Download Pdf Manuals