1. Enter a valid User code CG 3 CG CG CG and press Enter the zone number CG CG CD 2 3 Press to omit the selected zone Repeat for other zones if required 4 Press when finished Continue to arm the system as normal ch The Turn CHIME On and Off The system can be set up so that activating opening certain zones will cause the internal sounders to chime This would normally be used on a front door exit button etc Zones will only cause the internal sounders to chime if they are selected for chime see Master User Guide for details on selecting which zones chime Once a zone has been selected for chime the Chime facility can be manually turned on and off as required The system can also be programmed to automatically turn chime on and off under certain conditions i e certain times of the day door left open etc If no zones have been programmed for Chime then turning Chime on and off will have no effect To turn CHIME On To turn CHIME Off 1 Press 1 Press The Chime tone will sound The Error tone will sound INS555 2 5 Premier Elite Series User Guide To CHANGE Your User Code Users with access to this option can change their own User codes User codes are unique to each user and can be 4 5 or 6 digits long Only the User code that is entered to access the change code menu will be changed Before changing your code it is vital that you memorise or write down the new code you are about to program Failure to rememb
2. activity gt TEXECOM LID 2012 INS555 2 7
3. the 2 Entry time will start If the 2 Entry time expires an Intruder alarm will occur all internal and external sounders It is perfectly normal for the 2 Entry time to be programmed as zero in which case an Intruder alarm will occur as soon as the Entry time expires 1 Enter the premises via the designated entry point The entry tone will start 2 Enter a valid User code CD CG CG CG The entry tone will stop To DISARM the System When Not in Entry 1 Enter a valid User code gt gt gt 2 Press To CANCEL the Exit Mode Once the exit mode has been started you should leave the premises immediately however if for some reason you decide not to leave the exit mode must be cancelled 1 Enter a valid User code CD CG CD CD 2 Press ves The exit tone will stop To CLEAR an Arm Fail When the system tries to arm with zones active open the internal sounders will sound and the external strobe will be flashing to indicate a problem For details on preventing an Arm Fail condition please refer to page 7 A If you were not present when the Arm Fail occurred or you do not clear the Arm Fail the internal sounders will continue to sound and the external strobe will continue to flash 1 Enter a valid User code gt C The internal and external sounders will stop the external strobe will continue to flash and the number of the zone that caused the Arm Fail will be displayed 2 Enter a v
4. G to the keypad within 10 seconds 4 A confirmation tone will be heard the TAG is now programmed Arming To Arm the Control Panel proceed as follows 1 Present the TAG to the keypad the display will show Do You Want To Arm System 2 Present the TAG again or hold it in place and the exit will start leave the building If Quickarm is enabled the system will start the exit time immediately Disarming To Disarm the Control Panel proceed as follows 1 Enter the building Via the designated Entry point the entry tone will sound 2 Present the TAG to the keypad the entry tone will stop the alarm is now disarmed 6 INS555 2 Premier Elite Series User Guide SmartKey amp Quick Guide Smartkey Keypad Action For all SmartKey operations the SmartKey should be powered on by pressing and holding for 4 seconds e L eemeegeeereen oo mmmn EECHER de Rese ores cmenn OOOO foo O A Lazenenez Select Required Area using keys 1 8 Press Yes or press Chime to arm silently Ges OF Cm To Disarm the System Q 9 Q o r Enter a valid User code DDD Press Yes if the entry mode was not started oi O Crea S Ces Gime Enter a valid User code Geset OO To Cancel the Exit Mode Enter a valid User code L DOOD Enter a valid User code Enter a valid User code CODO Press Reset To Clear an Arm Fail Q Q Q o To Silence an Alarm To Reset After an Alar
5. User Guide Premier Elite Series Revision 2 Language Set 1 Pages EN Premier Elite Series User Guide 2 7 SV Premier Elite Serie Gebruikersgids 8 13 FR Premier Elite Series Guide de l utilisateur 14 19 NL Premier Elite Serie Gebruikersgids 20 25 DK Brugsanvisning til Premier Elite Series 26 31 lexecom NO Premier Elite Series bruksanvisning 32 37 H Premier Elite sarjan k ytt ohje 38 43 Desig ned to Perform i INS555 2 Premier Elite Series User Guide Introduction Users of the alarm system will be assigned a unique 4 5 or 6 digit User code and may be assigned a Proximity Tag or a SmartKey Codes Tags amp SmartKey are used to arm and disarm the system Some User codes can also access additional options such as system tests and omitting zones Keypads will be installed throughout the premises usually one at each entry exit door The keypads are used to perform all of the system operations i e Arming Disarming etc Most User codes can be used at any keypad on the system However Local Users will only be able to use certain keypads on the system Keys LED English Armed Info Ready Service V8 0 Function D E e E E Status J Disarm Part Arm Part Arm Disarm Arm else The Keypad Emergency Keys In case of emergency the alarm system can provide three immediate emergency alarms by pressing and holding two
6. alid User code gt gt gt gt and press To SILENCE an Alarm When an alarm occurs on the system the internal and external sounders will normally sound for a pre programmed time normally 15 minutes If you were not present when the alarm activated the internal and external sounders may have already stopped but the external strobe will still be flashing When alarm information is being displayed pressing the SCROLL key will slow down the display and also allow manual scrolling through the events Enter a valid User code C D C D D C D The internal and external sounders will stop and the number of the zone that caused the alarm will be displayed The alarm now needs to be reset To DISPLAY the cause s of System Alerts Alarms When silencing an alarm or unsetting the system after an alarm the number of the zone s will be displayed on the keypad If several zones were triggered the display will scroll through each in turn After noting the cause of the alarm the system can be reset as described in RESET After an Alarm below System Alerts When the system has faults to display or has not been reset after an alarm condition the display may show SYSTEM ALERTS Enter a valid User code CG CG CG CG Any alarms or faults will be displayed If several fault or alarm conditions have been triggered the display will scroll through each in turn After noting the cause of the alarm or fault the sy
7. ed when ALL zones are ON not omitted A Your Installer may have programmed the system so that it can be set by just pressing area if this is the case then there is no need to enter the User code below 1 Ensure that the premises are secure all doors and windows closed etc and the Ready light is on 2 Enter a valid User code CD CG CG CG Press to arm The exit tone will sound Leave the premises When the system has armed the exit tone will stop To PART Arm the System The system is PART Armed when ONE OR MORE zones have been left OFF omitted i e the landing or a bedroom CR The system is only Part Armed when zones are omitted using the Part Arm procedure omitting zones manually see page 5 for details is not classed as Part Arming The bottom line of the display is programmable for each Part Arm Your Installer may have programmed the system so that it can be Part Armed by just pressing O 3 or followed by Can if this is the case then there is no need to enter the User code below Ensure that the premises are secure all windows and doors not being omitted are closed and the Ready light is on Enter a valid User code CG CG CD CD Press Use keys a gt to select the required Part Arm Press to arm normally or press to arm silently The exit tone will sound if silent arm has not been selected Leave the protected area When the system has armed the exit tone if sounding will stop To ARM Individual Areas I
8. er your code will require an engineer visit to re program a new code for you This may incur a call out charge 1 Press Enter the User code that requires changing gt Press then Press Press then Press Enter a new 4 5 or 6 digit User code CG CG CD CG Press to accept the new code Press to exit the menu The display will return to normal oa Fb Oo N Using a Proximity Tag General Operation 1 A Proximity TAG must be held over the PROX symbol on the keypad 2 A Proximity TAG will normally work at distances of up to 4cm however it should be noted that distances can and do vary 3 Presenting a Proximity TAG to the keypad is NO different to entering a code except that it is a SINGLE action as opposed to a MULTIPLE action 4 The control panel will log which User TAG has been presented Programming Proximity TAGS Programming a Proximity TAG will depend on which type of control panel and what version of software is installed Your Installation Company can advise if it is possible to use Tag s on your system Determine your Panel Type From Day Mode press followed by 4 the keypad will display the Model and software version Note which Model you have and proceed as follows Programming To assign a Proximity TAG to a User proceed as follows 1 Program the User code as normal this new option will now appear at the end Do you want to Add TAG to User 2 Press 3 Present the Proximity TA
9. f the system has been split up into separate areas of protection i e Area 1 House Area 2 Garage Area 3 Shed etc These areas can be individually selected for FULL or PART arming as required A ch ao SF N Areas are selected by using keys CO gt the CS key can also be used to select an area followed by Or Co On the 640 there are 4 Area groups each with 16 Areas these can be selected by pressing the a key to select an Area Group 1 4 Only areas that exist on the system can be selected A Star means the area can be selected and a Dot means the area cannot be selected Pressing will select deselect all areas pressing will toggle between the first 8 areas and the second 8 areas where applicable Ensure that the premises are secure all windows and doors not being omitted are closed and the Ready light is on Enter a valid User code CG CG CG CG Press Use keys a to select the required areas Press or to FULL arm the areas Or on the 640 press INS555 2 3 ch gg Fb RM Premier Elite Series User Guide 6 Press a or followed by or 24 48 88 168 or 640 to PART arm the areas The exit tone will sound if silent arm has not been selected 7 Leave the premises When the system has armed the exit tone if sounding will stop To DISARM the System The entry time is divided into two sections the Entry time and the 2 Entry time If the Entry time expires an Internal alarm will occur and
10. indications The system is unarmed can also be programmed for other indications One or more zones are omitted No zones are omitted 2 INS555 2 Premier Elite Series User Guide Zone Faults During Arming Before attempting to arm the system ensure that the premises are secure all doors and windows closed etc and the Ready light is on H an attempt is made to arm the system with any zones active e g door ajar open window etc the internal sounders will bleep repeatedly fault tone and the display will show the zones that are active The fault tone will stop and the exit tone will resume when all zones are secure If it is necessary to leave a zone open then it must be omitted see page 7 for details If an active zone cannot be secured then it may be in fault in this case contact the alarm company immediately Arm Fail Failing to Arm If the exit procedure is started and zones are still Active at the end of the exit procedure an Internal alarm will occur internal sounders only and the strobe light on the external sounder will flash If this occurs the arm fail must be cleared and the zone in fault identified before the system can be armed see page 4 for details on clearing an Arm Fail The Ready LED To help prevent faults during arming a Ready light has been provided see table above for details on how the Ready LED operates Operating the Alarm System To FULL Arm the System The system is FULL Arm
11. m To Engineer Reset Contact Your Installation Company To Anti code Reset Enter a valid User code Contact Your Alarm Receiving Centre Quote 4 digit code shown on display Quote 3 Enter 4 digit code given by Receiving Centre del 0 o D Press Yes To Omit Zones Enter a valid User code 0 9 Q 9 Press Omit Q Q O Enter Zone Number s Press Omit to toggle omit status on off Press Menu when finished Press Yes to Arm Turn Chime On Off Press Chime Once to Turn ON Press Chime Again to Turn OFF ijj 0060 ag To Change User Code Enter a valid User code DIDID Press Menu followed by Yes Press 2 followed by Yes Enter a new 4 5 or 6 digit User code CO 2203 Press Yes to accept Press Reset to return to the normal display SmartKey status LED BUTTONS ALARM STATUS LED s Sue Se ARM 1 To turn on press and hold for 4 secs Green LED on Disarmed Green LED on Connection PART ARM 2 To Arm press Orange LED flashing Part Arming Red LED on No connection DISARM 3 To Part Arm press Sle ange A ee Armed POWER e lashing Arming hold 4 secs 4 To Disarm press RED LED on Armed 5 To activate Panic Alarm press and All 3 LED s flashing together Alarm Alarm status LED s DIS ARMED hold together for 4 secs All 3 LED s cycling Panic Alarm PART ARMED 6 To turn off press and hold for 4 secs 7 The SmartKey will power off after 20 ARMED secs of no
12. on you will still be able to silence the alarm by entering a valid User code see page 7 for details A The system cannot be armed again until the alarm has been reset 1 Enter a valid User code 3 CG CG CG 2 Press The display will show a random code number i e 4281 3 Contact the telephone number on the display if programmed or the telephone number on the last page of this User Guide and quote the random code number You will be given a 4 digit Anti Code i e 5624 4 Enter the Anti code that has been given to you D gt 5 Press If the Anti code is correct the keypad will bleep to indicate that the system has been reset and the display will return to normal To OMIT Zones It is possible to exclude omit individual zones when arming i e if a zone is in fault Users with access to this function can only omit zones that have been programmed as Omittable A If the zone can be omitted there will be a Star to the right of the zone number Only zones that have the Omit attribute assigned to them can be omitted A Star will appear to the left of the zone number to indicate that the zone has been selected for omitting All omitted zones will be automatically reinstated the next time the system is disarmed unless programmed otherwise To re instate zones manually simply follow the instructions again However when the key is pressed on this occasion the zones will be re instated
13. specific keys for two seconds Emergency Alarm Press Keys Panic Alarm PA cS The emergency keys can be enabled disabled for each keypad on the system The Panic alarm can be programmed for either audible or silent operation The Panic alarm can be programmed for either instant or delayed operation Wess The Keypad Quick Arm Keys The Quick Arm keys allow the system to be armed without having to enter a User code first The Quick Arm keys will only work if the keypad has been programmed to allow arming in this way To FULL arm the system press Garea To PART arm the system press a or followed by Can Keypad Lock The keys on the keypad can be locked to prevent unwanted access to the system The Emergency keys will NOT operate with the keys locked To Lock the keys press and together To Unlock the keys press and together again LED Indicators Five LED indicators have been provided to indicate the status of the system ED Status Te Meaning S On AC mains is present on the control panel AC Mains is not present the control panel is running on the standby battery On The system requires attention contact your installer Service a The system does NOT require attention On All zones are secure and the system is ready to be armed Off One or more zones are active The system has zones with the Force Omit attribute that are active The system is armed can also be programmed for other
14. stem can be reset as described in RESET After an Alarm below A Some action may be required to clear the cause of the alarm or fault in order to successfully reset the panel 4 INS555 2 Premier Elite Series User Guide To RESET After an Alarm If the display shows SYSTEM ALERTS follow the steps described in To DISPLAY the causes of System Alerts above before attempting to reset USER Reset Once the alarm has been silenced see page 7 for details the system will need to be reset CR If the system has been programmed to be reset by an Engineer pressing will not return the display to normal if this is the case see ENGINEER Reset for details The system may have been programmed to be reset by Anti code if this is the case see ANTI CODE Reset for details 1 Enter a valid User code CG gt CG CG CG 2 Press Cese The external strobe will stop the system will chime and the display will return to normal ENGINEER Reset If the system has been programmed to be reset by an Engineer following an alarm activation you will still be able to silence the alarm by entering a valid User code see page 7 for details The system cannot be armed again until the alarm has been reset Contact the telephone number on the display if programmed or the telephone number on the last page of this User Guide ANTI CODE Reset If the system has been programmed to be reset using an Anti Code following an alarm activati
Download Pdf Manuals
Related Search
Related Contents
GPS 安全性要約書 ジシラン - Mitsui Chemicals Quick Start Guide Samsung LN46C650L1F Sprint Vital User Guide 7610 User Manual - Robertshaw Climate User Manual - inShop.hu webáruház X-PRO Series Designers manual for V1-6 User`s manual complete - Sea INSYS Powerline GP CD-R/RW COMPATIBLE CD PLAYER 24Bit Current Injection Copyright © All rights reserved.