Home

Monarch Scaleout Installation Guide

image

Contents

1. Y Model No MONARCH WATER Installer amp User Guide Effective February 2013 For Monarch Scaleout Suppliers to H M the Queens Estate at Sandringham Monarch Water Ltd Halesworth Road Bramfield IP19 9HP 101986 784759 F 01986 784769 info monarchwater co uk Wwww monarchwater co uk MONARCH SCALEOUT INSTALLATION INSTRUCTIONS Thank you for choosing our SCALEOUT Please read the following carefully which if followed correctly should ensure the installation is trouble free Before you install the unit please ensure you have the correct model with regard to demand placed upon unit and also the water hardness Ensure models are used on all water hardness over 480ppm Monarch has a nationwide database on all water hardness s for your assistance A PLANNING THE INSTALLATION e Always observe the water byelaws Ensure there is only one rising main Make sure you have allowed space for access to the unit for any possible maintenance in the future e Check the water pressure and locate the rising main Be aware of condensation occurring in warm environments If condensation occurs we recommend the unit is sited in a small tray that allows the water to evaporate SITING THE SCALEOUT Fig 1 Where possible this should be close to the rising main T off for an untreated mains supply for the outside tap Ensure that the unit is not subject to below 4 or above 50C If siting the unit within a kitchen cupboard loft
2. Retrospective If the resin fails at 30 months then new resin will be replaced under the 3 year guarantee but charged at 30 36ths of the replacement resin cost plus delivery plus VAT PLEASE NOTE This guarantee has the following conditions and is not covered by the following 1 Damage caused by high water pressure we strongly recommend a5 bar water pressure limiting valve on the inlet to your water supply where daytime water pressure exceeds a static pressure of 3 5 bar 50psi 2 This Scaleout is suitable for a mains water supply only 3 Damage caused by a dirty mains water supply The installation of a Monarch Debris Filter cost 73 00 inc VAT amp postage on the supply to your unit cancels this clause The majority of debris in water is caused by local authority work on the water main If notified in advance by your local water authority please put your unit onto bypass see Fig 5 For Bypass Close both Inlet amp Outlet valves and open Bypass valve For Normal Service Open both Inlet amp Outlet valves and close the Bypass valve 4 Call outs due to incorrect installation If you have any queries when installing your Scaleout please call us on 01986 784759 5 The use of any other hoses than those provided Under no circumstances use washing machine hoses 6 The effect of aggressive water the degradation and or blinding of resin and or chlorine attack on resin 7 Under no circumstances plumb in the unit
3. etc Ensure that the base floor is adequately supported e Ifthe unit is being installed in your loft 1st 2nd floor etc it is recommended to house the unit within a plastic tank and insulate well e The overflow on the plastic tank should be a minimum of 34 in size Failure to install the unit in a suitable tank will void the Guarantee o 0 ow C NON RETURN VALVE In domestic applications i e house bungalow apartment flat etc a single check valve should be fitted All other applications require a double check valve D DRINKING WATER FACILITY The unit produces drinking water so unlike a salt based softener no dedicated tap is required E MATERIAL CHECK LIST e The unit includes an installation kit as relevant to the model ordered e For 28mm supplies a full upgrade for the unit is available details on request F WATER PRESSURE TEST e It is IMPORTANT that a pressure check is carried out e Low and high pressure can result in either damage to or failure of the unit e If daytime static water pressure exceeds 3 5 bar 50psi a5 bar pressure limiter should be fitted 50psi daytime pressure can reach nearly 100psi at night e Minimum dynamic pressure must exceed 1 5 bar e If in any doubt please call us on 01986 784 759 OPTION 1 WITH POST FILTER CONNECTED REMOTE TO SCALEOUT G INSTALL BYPASS VALVES amp NON RETURN VALVE Form an installation as per Fig 1 Below Scaleout water to service Outlet Valve By
4. in solid copper 8 The installation kit is only covered by the OEM twelve month parts exchange warranty only 9 Compensation as a result of cancelled appointments damage caused by or incorrect installation of the unit In the unlikely event of a fault put the unit onto Bypass see 3 above ref For Bypass until an engineer calls THE ABOVE DOES NOT AFFECT YOUR STATUTORY RIGHTS Incoming Water Conditions Min Max Operating pressure 1 5 5 bar Temperature 4 50C pH 6 5 8 5 Max Iron content 0 3 mg l Max Manganese content 0 05 mg l Max Copper content 1 3 mg l Oil amp Phosphates Free H2S Free Monarch National Service Coverage Areas Effective February 2012 The below Postcodes see map below are automatically covered by a3 year parts and 12 month labour warranty B CT LONDON inset OX SO BA CV LU PE SP BH DT LN PO SS BN GU ME RG TN BS GL MK RH CB HP NG SG CM IP NN SL CO LE NR SN IMPORTANT EEUE Scaleouts sold outside POSTCODE AREA MAP the above Postcodes are UNITED KINGDOM SEOPLAN to be covered strictly by Royal Mail a parts only exchange warranty All parts sent back to Monarch are at the expense of the sending parties All repaired or replaced items will be returned to the sender on ano charge basis whilst covered by the parts exchange guarantee Once the parts exchange guarantee has expired Monarch reserves the right to ma
5. stay clean We do not however recommend that crystal glass solid silver or silver plated items are washed in your dishwasher as etching may occur Less dishwasher liquid may be required and in certain cases this will also apply to rinse aid For best results use a natural soap detergent cleaning agent On dishwashers connected to untreated water you should continue to put salt into the dishwashers own softener It will help if your dishwasher could be de scaled prior to the installation of the Scaleout This would also apply to your shower cubicle too For best results use a phosphate free dishwashing detergent Outside Tap It is recommended to leave your outside tap on mains water Additionally in the wintertime we recommend that this tap is isolated via an internal valve to prevent freezing Existing scale Scaleout water will immediately begin to de scale your pipes and appliances Your hot water cylinder will take longer to de scale than your pipe work in some cases 12 18 months therefore you may notice different levels of Scaleout water for some time whilst the system is de scaling This is particularly noticeable in your bath and shower Scaleout water will have no adverse effect in your heating system In every case a corrosion inhibitor such as Sentinel X100 must be used Helping your kettle last longer Your kettle will continue to have an amount of scale but the level can be kept to a minimum by running the tap for 5 10
6. ke a charge for any SEE pg postage delivery labour q and parts charges that is deemed necessary NE Newcastie upon Tyne NG Nottingham rlington Co Durham Doncaster South Yorkshire rchester Dorset London SG Stevenage Hertfordshire SK Stockport Cheshire W 3 ley West Midlands on Monarch will endeavour to keep these charges at the lowest cost whenever possible level TW Twickenham UB Southall Middlesex W London WA Warrington n WD Watford WF Wakefield W Yorkshire IN Wigan j ap in whole or in part by any form or medium is prohibited without prior permission of YELLOW MARKETING INFORMATION LIMITED 1999 SCALEOUT INSTALLATION RECORD Original Installation Date 20 1st Resin Change Date 20 2nd Resin Change Date 20 3rd Resin Change Date 20 4th Resin Change Date 20 SPF10 INSTALLATION RECORD er 10 INSTALLATION DETAILS RECORD istallet Name coa ee Installer Address sesse Es Ge ee ee ee ee de Ge oe Go ee Geo eo ae EE NE EE N Postcode ee ee ee ee ese Guarantee Card return date 20 Y MONARCH WATER Additional Products available from Monarch Water Water Softeners Domestic Water Softeners Light Industrial Water Softeners Industrial Water Softeners Light Commercial Water Softeners Food Service Equipment Protection Calcium Filters Food Service Equipment Protection Water Filters Domestic Water Filters Food Service Equipment Protection Wate
7. let Valve Bypass Valve shut Non Return NN Inlet Valve Valve 1 open Supply to outside tap a E Pressure Limiting Valve if required SE se JUN This connection is not tightened STOP TAP ON OS INCOMING MAIN FIG 4 K INLET amp OUTLET CONNECTIONS See Fig 4 Under no circumstances use washing machine hoses or plumb the unit in solid copper pipe Connect the inlet hose from the INLET valve male iron adapter on the pipe work to the INLET of the Scaleout see directional arrow on top of unit Connect the outlet hose from the OUTLET valve male iron adaptor on the pipe work to the OUTLET of the Post Filter PLEASE NOTE 1 Spare fittings and hoses are included with your unit that may not be needed 2 The Scaleout comes with the Post Filter attached However the seal from the black adaptor on the inlet of the Post Filter has not been tightened see fig 4 This is to allow for easy disconnection if the Post Filter is fixed remotely and to ensure the fibre washer is not damaged Therefore please ensure this connection is tightened prior to installation 5 I TEST INSTALLATION FOR LEAKS Close Inlet and Outlet valves to the unit and open Bypass valve Open mains stopcock and flush the new pipe work for a minimum of 5 minutes This can be done using any mains water tap inside the property i e utility room kitchen cold tap or wash hand basin in a bathroom Close Bypass valve then open Inlet and Outlet valves slo
8. pass Valve shut Non Return INN Inlet Valve Valve epee eae HU ousie tap Pressure Limiting Valve gt a if required SIST SO STOP TAP ON C N INCOMING MAIN Checklist FIG 1 V Water pressure 1 5 5 bar 20 70psi V Access for maintenance H POST FILTER See Fig 2 Using the short chrome braided hose provided connect this to the OUTLET valve male iron adaptor on the pipework and the OUTLET connection of the Post Filter Fix SPF10 Post Filter to wall using bracket provided If this short hose is not appropriate an additional longer braided hose is included within the installation kit FIG 2 OUTLET VALVE OPEN HOSE FROM OUTLET OF SCALEOUT BYPASS VALVE CLOSED I INLET OUTLET CONNECTIONS See Fig 3 Under no circumstances use washing machine hoses or plumb the unit in solid copper pipe Connect the inlet hose from the INLET valve male iron adapter on the pipe work to the INLET of the Scaleout see directional arrow on top of unit Connect the outlet hose from the Scaleout to the INLET of the Post Filter When all hoses are connected final layout should resemble FIG 1 PLAN VIEW OF SCALEOUT CONNECTION HEAD FIG 3 INLET HOSE FROM INLET VALVE OUTLET HOSE TO INLET OF POST FILTER OPTION 2 WITH POST FILTER CONNECTED DIRECTLY TO SCALEOUT J INSTALL BYPASS VALVES amp NON RETURN VALVE Form an installation as per Fig 4 Below Scaleout water to service Out
9. r Purifiers Domestic Multiflo 3 Way Taps Domestic Monarch Water Ltd Halesworth Road Bramfield IP19 9HP T 01986 784759 F 01986 784769 info monarchwater co uk www monarchwater co uk www scaleout co uk
10. seconds prior to filling Additionally it is recommended to empty the kettle of any water left over from the previous use When emptying you may notice scale flakes and possibly milky water too This is normal and proof that the Scaleout is working at optimum performance Flakes are caused by taking the water to boiling point and will not happen elsewhere throughout your system The Scaleout exchanges Calcium ions into Calcium crystals Crystals are collected by the Post Filters internal cartridge which is to be changed annually or before in extremely hard water areas You may sometimes notice a white dust form after any water has evaporated This is non scale forming magnesium a flavour carrier being retained Any dust can simply be removed by wiping with a damp cloth on an as and when basis 10 Toilets Showers Taps etc Because there is no direct flow across these surfaces other than water splashing the old scale may need to be removed with a scale remover Any new accumulation will wipe off easily Installation Conditions Effective February 2013 The Monarch Scaleout is fully covered by a retrospective 3 year parts and 12 months labour guarantee for installation within the hard water regions of mainland England as detailed on Monarchs National Service Coverage Area from date of original purchase Installations outside this area are automatically covered by a3 year parts only exchange warranty Definition and example of
11. wly Allow water to run slowly until all air is purged from the unit then close tap Allow unit to rest for 15 minutes before future use Check for leaks GOING ON HOLIDAY e Fig 5 shows the valves in the Service position Bypass is closed and Inlet amp Outlet are open e We highly recommend you bypass your unit when going away on holiday e Simply turn Inlet Outlet and Bypass valves 74 turn to put valves into Bypass positions e Upon your return move valves back to the Service position as Fig 5 below FIG5 Bypass Valve shut Non Return MIN Inlet Valve Valve open Supply to outside tap NT Pressure Limiting Valve if reguired STOP TAP ON INCOMING MAIN Hints and Tips about your new Scaleout 1 2 Bath and shower surfaces will become smoother be careful in particular the young and infirm why not buy a bath mat Cut washing powder down by approx 40 If possible look to use a pure soap powder as this will help give optimum results Scaleout water will become available throughout your system in varying time spans Conventional systems tanks in your roof will take anything from 4 10 days whilst mains fed Pressurised Systems will give treated water within 2 3 days Dishwashers On most installations the dishwasher is to be connected to the Scaleout water We recommend that you continue to add a small amount of salt to the appliance as before as this helps the salt holder in the appliance