Home
Mira Platinum Wireless Controller User Guide
Contents
1. F3 Warm Up When this setting is on and the shower is started there is a short delay 5 seconds before water flows and temperature display will flash to indicate shower is waiting for selected display temperature to be achieved When shower stops temperature has been reached and shower is ready for use press D as normal If temperature cannot be found shower will stop automatically after 5 minutes When Warm Up setting is off temperature display will not flash and shower operates as normal Note When used with some combination boilers the warm up function may be impaired This is due to the functional nature of combination boilers F4 Clock Setting To set the time F5 Clock Display When Clock Display is on time is displayed when shower has stopped or after 10 seconds of inactivity whilst the shower is running When Clock Display is off the time is replaced by the showering temperature F6 Flow Range For use with High on off Pressure Combi Valve version only The water flow rate showering force can be adjusted to within a desired range by setting a low point and a high point During adjustment the shower will need to be started F7 Control Frequency An unreliable functioning of the appliance not always able to change settings of shower may indicate radio interference by another device transmitting locally on same channel Changing channel may resolve this problem FUNCTION M
2. Control Out Of Range Clock Display USING THE SHOWER Switch On Off gt Press ch to start or stop shower Temperature and flow settings will be same as when last used After a short period display will dim to help extend battery life Approximately 10 minutes after shower has stopped display will turn off automatically Shower will not run continuously for more than 30 minutes before stopping automatically 5 minutes when ECO function is set to on When Warm Up function is on there will be a short delay 5 seconds before water flows from shower Adjust Temperature gt While shower is running press or to adjust temperature Showering temperature appears on display in degrees Celsius C Adjust Flow gt Turn outer ring clockwise or anticlockwise to adjust flow Showering flow level appears on display in white bars FUNCTIONS The following functions can be altered individually to adjust how the shower operates F1 Maximum Showering Water Temperature This is the temperature the shower cannot go beyond when in use F2 Eco The shower will stop automatically after 5 minutes When this setting is on maximum available showering flow is limited to half the flow normally produced ECO symbol is displayed When setting is off maximum showering flow will be at full flow ECO symbol goes out when more than half flow is selected
3. Eire Telephone 01 459 1344 E mail sales modernplant ie Fax Dublin 01 459 2329 By Post Modern Plant Ltd Dublin Otter House Naas Road Clondalkin Dublin 22 Mira is a registered trade mark of Kohler Mira Limited The company reserves the right to alter product specifications without notice 1105041 W2 F N86A 1666 mira FM 14648 SHOWERS Kohler Mira Ltd February 2011
4. or H values set too Change to higher setting low in Flow Range F6 Drip from showerhead A small amount of water may This is normal Changing be retained in showerhead after position of showerhead may showering This may drain over vary draining time a few minutes Shower not hot enough Maximum showering Increase maximum showering temperature set too low temperature Function F1 Make sure hot and cold water supplies are connected correctly and delivering a constant flow and temperature within the required limits See Specifications in the Mira Platinum Installation Guide Digital Mixer fitted incorrectly If problem persists contact our Customer Services Team Incorrect or fluctuating Controller out of range Refer to Fault Diagnosis in temperature AE the Digital Mixer Installation Radio interference EE Guide Warm up feature is being used with combi boiler 22 Fluctuating or reduced flow Maximum blend temperature too hot or too cold Continuous flow Shower will not shut off Shower runs for a short time 30 60 seconds then flow reduces splutters or stops Worst when other hot taps are in use Less evident when shower is on full cold Shower runs for a short time 3 5 minutes Shower runs cool after a short time 1 2 minutes then flow splutters Shower runs cold after 5 10 minutes Filters blocked Water pressure too low Flow rate is too low F
5. ENU Enter the Function Menu P gt Press and cb buttons simultaneously until End is displayed on the unit BP Use or buttons to cycle through functions and press 5 to enter setting See following sections in this guide for details on each function and how to alter their settings Note If signal loss occurs during a function change Err will appear on display Press D to clear and retry function change Exit the Function Menu gt When finished use or buttons to cycle back through functions until End appears Press to exit B Control is ready to use If necessary test shower to see if functions are working as expected 10 CHANGING FUNCTIONS SETTINGS Maximum Showering Water Temperature Factory default 45 C Y Cycle menu to F 1 and press Dr P gt Press or to adjust temperature Maximum 48 C Minimum 35 C P gt Press tb to set gt Press to exit back to Function Menu See section Exit the Function Menu 11 Eco Factory default off Y Cycle menu to F 2 and press dh p gt Press or to change setting on or off p Press 0 to set Press to exit back to Function Menu See section Exit the Function Menu 12 Warm Up Factory default off Note Function will not work with combi
6. e cleaned with a mild washing up detergent or soap solution and then wiped dry using a soft cloth DISPOSAL AND RECYCLING End of Product Life When the appliance has reached the end of its serviceable life it should be disposed of in a safe manner and in accordance with current local authority recycling or waste disposal policy Batteries Spent batteries should not be disposed of with your normal household waste Contact your local authority for information on waste disposal and recycling This symbol on the product or its packaging indicates that this product should not be disposed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local council office your household waste disposal service or the shop where you purchased the product NOTES 25 NOTES 26 NOTES 27 CUSTOMER SERVICE Guarantee Your product has the benefit of our manufacturer s guarantee which starts from the date of purchase To activate this guarantee please retu
7. er guides diagnose faults purchase our full range of accessories and popular spares refer to our FAQ s and request a service visit Spares and Accessories We maintain extensive stocks of genuine spares and accessories and aim to provide support throughout the product s expected life Payment can be made by phone at time of order using most major Credit or Debit cards and we aim to despatch orders within 2 working days Items purchased from us are guaranteed for 12 months from date of purchase For safety reasons spares exposed to mains voltages should only be fitted by competent persons Returns items can be returned within one month of date of purchase providing that they are in good condition and the packaging is unopened Please obtain authorisation from our Customer Services Team before return We reserve the right to apply a 15 restocking charge Service Repairs We have a nationwide team of Service Technicians can carry out service or repair work to your product within the guarantee period and beyond You have the assurance of a fully trained Technician genuine spare parts and a 12 month guarantee on any chargeable work done Payment should be made directly to the Service Technician who will accept most major Credit or Debit cards To Contact Us UK Telephone 0844 571 5000 E mail technical mirashowers com Fax 01242 282595 By Post Mira Customer Services Dept Cromwell Road Cheltenham Gloucestershire GL52 5EP
8. luctuating water temperature Incorrect maximum temperature setting Wireless Controller or Digital Mixer Valve failure Air is being sucked down the vent pipe Gravity fed system Warm up setting inadvertantly selected Cistern capacity insufficient 230 litres minimum required Eco setting selected Air ingress into hot pipework Insufficient storage of hot water in cylinder 23 Refer to Fault Diagnosis in the Digital Mixer Installation Guide Refer to Maximum Shower Water Temperature in the Digital Mixer Installation Guide Isolate power and water supplies Contact our Customer Services Team The hot draw off pipe is positioned too high in relation to the lowest water level of the cold water cistern 100 mm min refer to Gravity Fed Showers diagram in the Digital Mixer Installation Guide Consider increasing size of cold feed pipe to cylinder to 28 mm diameter Disable Warm Up feature Refer to Function Menu Warm Up Increase cistern size Disable Eco feature Refer to Function Menw Eco Refer to plumbing system diagrams under Installation in the Digital Mixer Installation Guide for correct connection Increase storage of hot water CLEANING Many household cleaners contain abrasives and chemical substances and should not be used for cleaning chrome plated or plastic fittings These finishes should b
9. m A Platinum Mira Platinum Wireless Controller User Guide CONTENTS Introduction 3 OMEN AN essen ea en aan dere ane A 3 Safety Information croce nre eec NOCNE 3 Control MM Go LY OP it nnn eiciteriinterrerii ge 4 Display Symbols aiino uiuunt nn asa nu kann rada u inania 5 Using the Shower 6 Switch On OM e 6 Adjust Temperature iones 7 AJUS FION 2 Here ee M 7 RUNCIONS 8 Function Menu iaa 9 Enter the Function Menu einen aan cren intrent inne tnn 9 Exit the Function MOU ies oec otto ul 10 Changing Functions Settings eene 11 Maximum Showering Water Temperature seseeeee 11 ECO c 12 MEI 13 Bon dBI m 15 gie datae ee 16 erenmirollre 18 Replacing the Batteries usunssnsesnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nn 19 Fault DIAagnNosIS iii 20 ETTORCOES aiii 20 General Fluid 22 CIC AINMING iii a tia 24 Disposal and Recycling seseina keinen antrena EENKEER NEES 24 Notes eee eh RE EERE 25 Customer SetviC6 A eee ste evceunctsseventectzedecesearese 28 INTRODUCTION General Thank you for purchasing a quality Mira product To enjoy the full potential of your new product
10. nation boilers Y Cycle menu to F 3 and press hr p gt Press or to change setting on or off P gt Press 0 to set Press to exit back to Function Menu See section Exit the Function Menu 13 Clock Setting Factory default 4 00 Note Can also be activated by disconnecting and reconnecting battery Cycle menu to F 4 and press br P Press to change hour setting P gt Press to change minute setting P gt Press to set time and exit back to Function Menu See section Exit the Function Menu 14 Clock Display Factory default on Y Cycle menu to F 5 and press dy gt Press or to change setting on or off P Press 0 to set Press to exit back to Function Menu See section Exit the Function Menu 15 Flow Range For use with High Pressure Combi Valve version only Factory default 1 99 gt Cycle menu to F 6 and press O P on is displayed press to start shower P Lower limit is displayed e g L 1 Adjust flow to desired lower limit 1 99 P gt Press to set lower limit 16 Higher limit is displayed e g H 23 Adjust flow to desired higher limit 1 99 Most plumbing systems may achieve maximum flow before 99 gt Press to se
11. ntial loss of any kind e Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative e Routine maintenance or replacement parts to comply with the requirements of the TMV 2 or TMV 3 healthcare schemes e Products purchased ex showroom display What to do if something goes wrong If your product does not function correctly when you first use it contact your installer to check that it is installed and commissioned in accordance with the instructions in this guide If this does not resolve the issue contact our Customer Services Team who will offer you or your installer help and advice If you experience problems check in this manual to see if simple home maintenance is required If you require further assistance call our Customer Services Team Extended Guarantees A selection of protection plans are available that enable you to cover repair bills for the life of your policy excludes Eire Ring 01922 471763 for more details Helpdesk Service Our Customer Services Team is comprehensively trained and can offer help and advice spare parts accessories or a service visit We will need you to have your model name or number power rating if applicable and date of purchase As part of our quality and training programme calls may be recorded or monitored Mira Showers Website www mirashowers co uk From our website you can register your guarantee download additional us
12. please take the time to read this guide thoroughly and keep it handy for future reference The Mira Platinum Wireless Controller is a remote user interface and controls the following functions Showering Water Temperature Showering Water Flow Maximum Showering Water Temperature Eco Mode Warm Up Mode e Clock Flow Range This guide covers the setting and use of these functions and includes a trouble shooting guide should the appliance not function as expected For issues relating to the installation of the appliance or other associated products please refer to the relevant Installation Guide s or contact our Customer Services Team Details in the back of this guide NOTE ALL FUNCTIONS ARE ONLY AVAILABLE AFTER THE CONTROLLER HAS BEEN ASSIGNED TO A MIRA PLATINUM DIGITAL MIXER VALVE See Mira Platinum Installation Guide SAFETY INFORMATION 1 Make sure that you fully understand how to operate this shower and make sure that it is properly maintained in accordance with the instructions given in this manual 2 Sunburn or skin conditions can increase your sensitivity to hot water Make sure that you set the shower to a cooler temperature CONTROL LAYOUT Turn Outer Ring Showering Water Flow Adjustment Decrease Increase Flow Flow Increase Temperature Decrease Temperature Start Stop Display DISPLAY SYMBOLS Low Battery Display Economy Flow Display Temperature Display ow Display
13. r Services Team Error Code Number Not Previously Described Digital Mixer PCB Error 1 Turn Digital Mixer off for 15 seconds Turn back on and allow 15 seconds to reset 2 If problem still occurs make a note of the error code and contact our Customer Services Team Replace batteries Control out of range Error During Function Change Displayed if there is a signal loss between the Wireless Control Unit and the Digital Mixer whilst a function setting is being altered Press to clear the display and retry the function change 21 General Faults Malfunction No display The batteries are flat or Check and rectify incorrectly fitted Shower will not operate Water supply isolated Check water supply Flat batteries Replace batteries Electrical supply isolated or fuse Check electrical supply If fuse blown blown replace Digital Mixer Valve PCB O No connection to Digital Mixer Reset and recommission Refer Control out of range to Installation Guide 0 Digital Mixer malfunction Isolate electrical supply and reset after 30 seconds If problem persists contact our Customer Services Team No flow or low flow from Showerhead blocked Check and clean Shower Fittings re Stuck Checkvalve in Check and clear or replace Showerhead Checkvalve Hose blocked or twisted Check and clean or release twist Digital Mixer malfunction Contact our Customer Services Team L and
14. rn your completed registration card visit our website or free phone 0800 0731248 within 30 days of purchase UK only Within the guarantee period we will resolve defects in materials or workmanship free of charge by repairing or replacing parts or product as we may choose This guarantee is in addition to your statutory rights and is subject to the following conditions e The guarantee applies solely to the original installation under normal use and to the original purchaser only The product must be installed and maintained in accordance with the instructions given in this user guide Servicing must only be undertaken by us or our appointed representative Note if a service visit is required the product must be fully installed and connected to services Repair under this guarantee does not extend the original expiry date The guarantee on any replacement parts or product ends at the original expiry date e For shower fittings or consumable items we reserve the right to supply replacement parts only The guarantee does not cover e Call out charges for non product faults such as damage or performance issues arising from incorrect installation improper use lack of maintenance build up of limescale frost damage corrosion system debris or blocked filters or where no fault has been found with the product e Water or electrical supply waste and isolation issues Compensation for loss of use of the product or conseque
15. t higher limit B gt Press to set and exit back to Function Menu See section Exit the Function Menu 17 Control Frequency Factory default 1 gt Cycle menu to F 7 and press h gt Press or to change channel 1 7 p Press to set Press 0 to exit back to Function Menu See section Exit the Function Menu 18 REPLACING THE BATTERIES To access the batteries the control unit must be removed from the wall Make sure control unit is dry before removing gt Press button to release and remove control from wall gt Turn unit over to access batteries Remove and replace all batteries Only use new batteries of same make and type Do not use rechargeable batteries Hook control on top of bracket and push firmly until control clicks back into place p If necessary test shower to see if functions are working as expected 19 Error Codes FAULT DIAGNOSIS A specific problem relating to the electronic function of the shower will result in an error code being displayed on the control Over Temperature at Control Sensor 1 Turn Digital Mixer off for 10 seconds Turn back on and allow 15 seconds to reset If shower operation does not return to normal make sure hot and cold inlets are not reversed If shower operation does not return to normal make sure inlet filters and check val
16. ve cartridges are clean If shower operation does not return to normal check the water supplies to the valve are within the correct temperature and pressure ranges See Mira Platinum Installation Guide Specifications If problem still occurs make a note of the error code and contact our Customer Services Team Control Sensor 1 Turn Digital Mixer off for 15 seconds Turn back on and allow 15 seconds to reset 2 If shower operation does not return to normal replace Thermistor To be performed by competent tradesperson only 3 If problem still occurs make a note of the error code and contact our Customer Services Team 20 Control Sensor or PCB Relay 1 Turn Digital Mixer off for 15 seconds Turn back on and allow 15 seconds to reset 2 If shower operation does not return to normal replace Thermistor To be performed by competent tradesperson only 3 If shower operation does not return to normal replace PCB To be performed by competent tradesperson only 4 If problem still occurs make a note of the error code and contact our Customer Services Team Digital Mixer Temperature Motor 1 Turn Digital Mixer off for 15 seconds Turn back on and allow 15 seconds to reset 2 If shower operation does not return to normal check and if necessary replace Mixer Valve To be performed by competent tradesperson only 3 If problem still occurs make a note of the error code and contact our Custome
Download Pdf Manuals
Related Search
Related Contents
acrobat - Accueil Bissell Swiffer BISSELL STEAMBOOST Steam Mop 6639 Owner's Manual 8.3 ENGINE KOHLER K-3639-0 Instructions / Assembly Guide de programmation - CCTV Modbus Option Board Catalogue tovamed 14-12 - Présentation générale SGH Swiss Speco Technologies HT7715DNVW User's Manual Copyright © All rights reserved.
Failed to retrieve file