Home

10 TROUBLESHOOTING

image

Contents

1. SW and SW 1 on _ Ignition SW SW 1 and Relay on Connect the Relay and SW 2 off or Disconnect SW 2 d Disconnect and reconnect the connectors while watching the test light The short lies between the connector where the test light stays lit and the connector where the light goes out e Find the exact location of the short by lightly shaking the problem wire along the body CAUTION Do not open the cover or the case of the ECU unless absolutely necessary If the IC terminals are touched the IC may be destroyed by static electricity DISCONNECTION OF MALE AND FEMALE CONNECTORS To pull apart the connectors pull on the connector itself not the wire harness HINT Check to see what kind of connector you are disconnecting before pulling apart Press Down Press Down TROUBLESHOOTING Reference HOW TO REPLACE TERMINAL Retainer at Full Lock Position k Terminal Stopper Retainer Secondary Locking Device 12 with terminal retainer or secondary locking device 1 PREPARE THE SPECIAL TOOL HINT To remove the terminal from the connector please construct and use the special tool or like object shown on the left DISCONNECT CONNECTOR DISENGAGE THE SECONDARY LOCKING DEVICE OR TERMINAL RETAINER a Locking device must be disengaged before the terminal locking clip can be released and the terminal removed from the connector b Use a special tool or the terminal pick to unlock t
2. TROUBLESHOOTING 10 To Ignition SW IG Terminal VOLTAGE CHECK a Establish conditions in which voltage is present at the check point Example Ignition SW on Ignition SW and SW 1 on Ignition SW SW 1 and Relay on SW 2 off b Using a voltmeter connect the negative lead to a good ground point or negative battery terminal and the positive lead to the connector or component terminal This check can be done with a test light instead of a voltmeter CONTINUITY AND RESISTANCE CHECK a Disconnect the battery terminal or wire so there is no voltage between the check points b Contact the two leads of an ohmmeter to each of the check points If the circuit has diodes reverse the two leads and check again When contacting the negative lead to the diode positive side and the positive lead to the negative side there should be continuity When contacting the two leads in reverse there should be no continuity c Use the volt ohmmeter with high impedance 10 kQ V minimum for troubleshooting of the electrical circuit To ignition SW IG Terminal Test Bulb Fuse Case Short Disconnect Disconnect Relay Short Disconnect Solenoid FINDING A SHORT CIRCUIT a Remove the blown fuse and disconnect all loads of the fuse b Connect a test light in place of the fuse c Establish conditions in which the test light comes on Example Ignition SW on Ignition
3. ase 2 Type which cannot be pulled as far as Power Lock 13 TROUBLESHOOTING Retainer at Full Lock Position PRR Seay Retainer at Temporary Lock Position Male Female c a 14 HINT Insert the tool straight into the access hole of terminal retainer as shown Push the terminal retainer down to the temporary lock position Release the locking lug from terminal and pull the terminal out from rear 4 INSTALL TERMINAL TO CONNECTOR Insert the terminal Make sure the terminal is positioned correctly Insert the terminal until the locking lug locks firmly Insert the terminal with terminal retainer in the temporary lock position Push the secondary locking device or terminal retainer in to the full lock position 5 CONNECT CONNECTOR
4. he secondary locking device or terminal retainer NOTICE Do not remove the terminal retainer from connector body For Non Waterproof Type Connector HINT The needle insertion position varies according to the connector s shape number of terminals etc so check the position before inserting it Case 1 Raise the terminal retainer up to the temporary lock position Case 2 Open the secondary locking device Example Case 1 Terminal Retainer Access Hole Male A Mark Female ARAN Th dii Retainer I at Full Lock Position Sa A i NI q PX CIN PUSES ee o pst ee ge ae i i Ay J t v PFY ta BSNS ie it a i 1 boi E D E Retainer at Temporary Lock Position Female Example Case 2 Tool AEA Female Male Press Down For Waterproof Type Connector HINT Terminal retainer color is different according to connector body Example Terminal Retainer Connector Body Black or White Gray Black or White Dark Gray Gray or White Black Case 1 Type where terminal retainer is pulled up to the temporary lock position Pull Type Insert the special tool into the terminal retainer access hole 4 Mark and pull the terminal retainer up to the temporary lock position HINT The needle insertion position varies according to the connector s shape Number of terminals etc so check the position before inserting it C

Download Pdf Manuals

image

Related Search

Related Contents

convoyeur à chaîne pour grosses balles rondes manuel d  Online Trading DEMO  USER`S MANUAL AND EXAMPLE PROBLEM FOR UT  取扱説明書 (4327KB)  Aries Wings Radio Quick Installation Guide      Langage poétique : écart ou errance du sens  Samsung PL150 Manual de utilizare  Manual do Usuário  

Copyright © All rights reserved.
Failed to retrieve file