Home

Operating instructions GB

image

Contents

1. BRANTLOR E ONA Operating instructions English To operate this appliance properly and safely read the following instructions carefully 1 1 Introduction This appliance model HW 10 is a simple When you push the on off switch the water boiler The cold water is poured water will heat The signal lamp in the into the kettle by hand switch will light up Figure 1 shows the main components Figure 2 shows the appliance s and controls dimensions FIGURE 1 THE APPLIANCE IS SUPPLIED WITH THE 1 Water supply inlet with funnel FOLLOWING ACCESSORIES 2 On off switch Drip tray 3 Tap Water boiler lid 4 Temperature setting Screwdriver 5 Electrical connection 1 sachet RENEGITE descaler TECHNICAL DATA MOJO ccoo asiste is tE see HW 10 001 Water reservoir capacity 4 5 litre Capaci eienen 21 l h Discharge capacity 2 l h COTAJENJ ussen ca 150 cm Supply voltage 230 V RAUNO erei cze dar a a A 2080 W PROVE CUON seen IDA t 1 1 2 Warning For safe operation of the water boiler pay close attention to the following points 1 2 When the appliance Is In operation some components will get very hot If the appliance is unused for a long period of time it is advisable to dis connect the electrical supply Under normal circumstances a small quantity of water always remai
2. W EARTH TERRE ii ROEN ERDE MRDE 230V 1 phase with plug connection Fig 3 Please take note of the following in regard to figure 3 If equipped with a fuse plug the appli ance must be protected with a 13 A fuse If another plug is installed the appliance must be protected with a 15 A fuse Ifthe plug supplied with the appliance does not fit into your socket it should be cut off and replaced with a new plug The old plug should then be dis posed of as it can be dangerous if in serted into a socket Keep the following instructions in mind when installing a new plug The yellow green core earth must be connected to the terminal marked with the letter E or the earth symbol or coloured green or yellow green The blue core neutral must be con nected to the terminal marked with the letter N or coloured black The remaining brown core live must be connected to the terminal marked with the letter L or coloured red IMPORTANT The triple core supply cord in fig 3 is colour coded as follows Green and yellow earth Blue neutral Brown live INITIAL OPERATING PROCEDURE The following procedure is to be carried out when operating a new appliance for the first time 1 Remove the funnel 2 Clean the inside of the kettle as tho
3. keep the instructions given in the Introduction points 4 through 9 and 13 in mind CLEANING The water boiler can be cleaned with a damp cloth The drip tray etc can be washed in the usual way DESCALING Under normal operating circumstances calcium deposits will appear in the appli ance The appliance must be regularly descaled in order to function properly at least once every 6 months We advise for this purpose RENEGITE a descaling agent which we have tested ourselves The following instructions are based on the use of 100 gr of RENEGITE read the instructions on the packet as well The descaling procedure is as follows 1 If the appliance is on it must be switched off and as much hot water as possible drawn off via the tap Cool the appliance by refilling it with cold water 2 Remove the plug from the socket 3 When the appliance has cooled down remove the funnel from the kettle 4 Empty the kettle of water by tilting the appliance 5 Dissolve 100 gr descaler in ca 2 litres lukewarm water 6 Pour the solution carefully into the hot water kettle Do not replace the funnel SUBJECT TO MODIFICATION 10 11 13 14 15 17 18 19 Now replace the plug in the socket switch on the appliance and wait ca 10 minutes Then replace the funnel in the kettle and fill up to ca 3 cm from the brim Draw off a cup of descaler solution three or four times a minute via
4. ns in the appliance please keep this in mind if it is to be exposed to temperatures below O C Stay with the appliance during main tenance operations such as desca ling When working with strong cleaning or descaling agents it is most advisable to wear safety goggles face protector and gloves After working with strong cleaning or descaling agents be sure to wash your hands 7 Never immerse the appliance in water 8 Make sure that all repairs are carried out by qualified technicians 9 When the appliance has to be opened for repairs or maintenance be sure to disconnect the electricity 10 The appliance must always be connected to the mains in such a way that it can be easily disconnected 11 The appliance must be earthed 12 Be sure to observe local regulations and standards when installing the appliance 13 Prevent spillage of the descaler solu tion on to the outside of the machine this can cause permanent damage to the exterior surface of the machine housing In the event of a spillage wipe area affected dry whilst observing the safety regulations as given in the Users Instructions 1 3 Installation and initial operating procedure INSTALLATION When installing the appliance keep the instructions given above points 10 through 12 in mind Position the appliance on a solid level base where it can be easily connected to the electrical mains NEUTRAL ON
5. roughly as possible either with a damp cloth or by rinsing with hot water 3 Replace the funnel 4 Pour ca 4 5 litres water into the funnel 5 When the water is hot draw off as much of it as possible via the tap and dispose of it 6 Then refill the funnel with cold water to ca 3 cm under the brim The appliance is now ready for normal use Fig 4 ADJUSTMENT The temperature of the water in the reservoir can be adjusted The temperature can be set on the right side of the machine fig 4 by means of the screwdriver supplied Turn the screwdriver tot the right to increase the temperature Turn the screwdriver tot the left to decrease the temperature WARNINGS FOR THE ADJUSTING When adjusting our machines the following rules must be observed 1 When adjusting the water temperature ensure that the water within the machine does not reach boiling 2 The supplier is not liable for any negative effect caused by a changed adjustment of the machine 1 4 Operation Set switch 3 fig 1 in the on position the switch light will go on The element will now heat the water to ca 95 C via the tap and the water can be drawn off via the tap When no more hot water can then be drawn off via the tap the kettle should be topped up again to ca 3 cm under the brim of the funnel 1 5 Maintenance WARNING Always stay with the appliance during maintenance tasks such as descaling or cleaning and
6. the hot water tap and pour it into the funnel again Thus giving this a good descaling too Then switch the appliance off again and remove the plug from the socket Now draw off as much solution as possible via the tap and cool the kettle by refilling it with cold water Draw off as much solution as possible via the tap Remove the funnel again and pour the remaining descaler solution out of the kettle CAUTION Wear good protective gloves Now pour ca 5 litres water into the reservoir do not allow it to overflow Draw off as much water as possible via the normal hot water tap and dispose of it Pour the rest of the water out of the kettle Repeat operations 14 15 and 16 at least twice Rinse the funnel well a few times with hot water before replacing it in the kettle Now fill the appliance again with cold water up to ca 3 cm from the funnel brim The appliance is now ready for normal use 205 49 224 134 358 140 432 31 N COFFEE BREWING MACHINES i

Download Pdf Manuals

image

Related Search

Related Contents

Livret pédagogique - Le plaisir d`apprendre  La Base Frantext  Xantech RS2321X8 User's Manual  Assemblée générale ordinaire du jeudi 30 mai 2013    MORIWAKI AL TOPBRIDGE  Verificar os níveis de tinta estimados  7 PASIVOS AMBIENTALES Y RBCA  

Copyright © All rights reserved.
Failed to retrieve file