TN2 Thermometer Operating Instructions

image

Contents

1. with water or medical alcohol allowing the lens to fully dry before using the TN2 do not submerge any part of the TN2 The TN2 should be stored at room temperature between 10 to 40 C EMC RFI Readings may be affected if the unit is operated within a radio frequency electromagnetic field strength of approximately 3 volts per metre but the performance of the instrument will not be permanently affected PRODUCT WARRANTY amp GUARANTEE This instrument carries a one year warranty and guarantee against defects in either components or workmanship During this period products that prove to be defective will at the discretion of ETI Ltd be either repaired or replaced without charge The product warranty and guarantee does not cover damage caused by fair wear and tear abnormal storage conditions incorrect use accidental misuse abuse neglect misapplication or modification or use with non ETI Ltd hardware software No warranty of fitness for a particular purpose is offered and the user assumes the entire risk of using the product Any liability by ETI Ltd is limited only to the replacement of defective materials or workmanship and ETI Ltd accepts no responsibility for consequential loss In line with our policy of continuous development we reserve the right to amend our product specification without prior notice ss Electronic Temperature Instruments Ltd T Dominion Way Worthing West Sussex BN14 8NW Tel 01903 202151 E mail sale
2. TN2 Thermometer Operating Instructions The TN2 thermometer is a non contact infrared thermometer Simply aim the thermometer at the target and press the measurement button to display the surface temperature By partially pressing the measurement button the device will begin to measure the temperature of the target When the measurement button is completely depressed the laser will operate CAUTION DO NOT look directly into the laser beam permanent eye damage may result MINIMUM OR MAXIMUM MODE To utilise the TN2 s minimum or maximum mode firstly turn the instrument on by pressing the measurement button then press the mode button once for minimum or twice for maximum function The MIN or MAX icon will flash then press the measurement button to confirm the minimum or maximum mode The TN2 will display the minimum or maximum reading only LOCK MODE The lock mode is particularly useful for continuous monitoring of temperatures To utilise the TN2 s lock mode firstly turn the instrument on by pressing the measurement button then press the mode button three times for the lock mode function The LOCK icon will flash then press the measurement button to confirm the lock measurement mode The TN2 will continuously display the temperature for up to 60 minutes or until the measurement button is pressed C or F MODE To change the TN2 from C to F or from F to C firstly turn the instrument on by pressing the measurement but
3. TN2 to stabilise to the working room temperature 0 to 40 C For all other error messages it is necessary to reset the TN2 To reset lt the TN2 turn the instrument off remove the battery and wait for a r minimum of one minute insert the battery and turn on If the error E T message remains please contact the ETI Service Department for further assistance BATTERIES The TN2 has two separate batteries The battery closer to the side of the laser beam output is for laser operation only The other battery is designated for temperature measurements The TN2 can still measure temperature properly even without the laser battery The TN2 incorporates visual low battery indication as follows Battery OK measurements Battery Low battery needs to be Battery Exhausted are possible replaced measurements are measurements are possible not possible BATTERY REPLACEMENT When the Low Battery icon indicates the batteries are low the batteries should be replaced immediately with two CR2032 lithium cells ETI Order Code 839 095 The batteries are located under the twist covers at the rear of the TN2 Please note It is important to turn the instrument off before replacing the batteries otherwise the TN2 may malfunction STORAGE amp CLEANING The sensor lens is the most delicate part of the TN2 The lens should be kept clean at all times care should be taken when cleaning the lens using only a soft cloth or cotton swab
4. s etiltd co uk a n M www etiltd co uk 814 055 10 11 05
5. ton then press the mode button four times the C or F icon will flash press the measurement button to change the scale then press the measurement button to confirm the mode EMISSIVITY The TN2 infrared thermometer is supplied with a default emissivity of 0 95 The emissivity of the TN2 can be changed from 0 01 1E to 1 100E Changes should only be carried out by experienced personnel To change the TN2 s emissivity firstly turn the instrument on by pressing the measurement button then press the mode button five times for emissivity function The 95E will flash on the LCD screen then press the measurement button to adjust the emissivity value press the mode button again to exit the set up screen For information relating to the emissivity of specitic materials please contact the ETI Sales Office Note non contact infrared thermometers are not recommended for use in measuring the temperature of shiny or polished metals LCD ERROR MESSAGES The TN2 incorporates visual diagnostic messages as follows Hi or Lo is displayed when the temperature being measured is outside I ofthe range of the instrument Hi when higher than 250 C and L o Lo when lower than 33 C Er2 is displayed when the TN2 is exposed to rapid changes in the ambient temperature Er3 is displayed when the ambient temperature of the TN2 exceeds 10 or 50 C In both cases you should allow Er a E J plenty of time minimum 30 minutes for the

Download Pdf Manuals

image

Related Search

Related Contents

HP Photosmart 240 Series Basics Guide  RM1121 User Manual - RADIANT COMMUNICATIONS  Emplaste Renovacion 9370  Frigidaire 318200710 User's Manual  D Ultraschall Vernebler Gebrauchsanweisung  InLine 3.5mm - 3.5mm, 2m  

Copyright © All rights reserved.
Failed to retrieve file