Home
OPERATING INSTRUCTIONS
Contents
1. from injuring other people or damaging property DO NOT even try to use a pressure washer on machinery or electrical equipment that is connected in any way to the mains supply ALL switches in the OFF position pull out plugs if possible remove fuses Cover or seal electric motors and fittings to prevent entry of water Before reconnecting electric mains supply check for water penetration DO ALL you can to keep plugs and sockets in a dry place or covered to prevent entry of water ALWAYS when using this machine e wear safety goggles and helmet or helmet with a visor e Wear waterproof clothing and gloves e Take paticular care with detergents and chemicals NEVER attempt to disconnect any hose with pressure in it or allow the hose to be flattened or kinked DO NOT use a high pressure hose from a ladder Use a platform tower or proper scaffolding Should the equipment fail to operate DO NOT attempt to rectify or repair but contact the nearest Service Centre for advice Always rinse your pump out after using sea water PREPARATION Water Supply A Ensure there is an adequate water supply either from the mains or a reservoir B Attach water supply hoses to suitable tap or immerse the suction hose with approved suc tion filter into the reservoir NOTE ONLY CLEAN WATER SHOULD BE USED THE PUMP MAY BE DAMAGED IF DIRTY OR CONTAMINATED WATER IS ALLOWED TO PASS THROUGH THE PUMP Hoses Low pressure inlet For models up t
2. OPERATING INSTRUCTIONS SAFETY Water at high pressure is dangerous and can cause serious injury This machine is to be used with great caution Petrol is extremely flammable and explosive under certain conditions EXHAUST FUMES CONTAIN CARBON MONOXIDE Inhalation of such fumes can KILL Diesel is flammable and harmful if swallowed Always refuel in an area which is adequately ventilated DO NOT smoke when refueling Avoid overfilling Should fuel be spilt wipe off any fuel spilt on machine or engine Move the equipment away from the area where fuel has been spilt DO NOT refuel when the engine is running DO NOT run the engine in an area which has a hazardous or explosive atmosphere Always ensure that the fuel cap is secure after refueling Keep the engine at least 3 metres or more away from any other equipment or Building Take care not to get fuel on your clothing If this happens CHANGE your clothing IMMEDIATELY DO NOT start an engine when clothing has been contaminated with fuel Use only approved type containers for fuel DO NOT stand them out in strong sunlight keep them in the shade Always ensure that there is a suitable type fire extinguisher available and is within easy access DO NOT leave an engine running unattended ALWAYS STOP it before leaving the area NEVER point the high pressure spray jet at any person animal glass or other Material which may shatter PREVENT any over spray
3. o 13 litres per minute use bore suction hose or feed pipe For models from 13 litres to 24 litres per minute use bore suction hose or feed pipe Hoses High pressure outlet For all models use 3 8 RIT or 3 8 R2T hoses A Check the condition of the O rings in the ends of the hose B Attatch the high pressure hose to the pump connection G Attatch the spray gun to opposite ends of the high pressure hose OPERATION A Turn on the water supply B Start the engine C Direct lance on to surface to be cleaned Press the lance trigger Adjust pressure regulator as required to obtain working pressure if required NOTE The high pressure water will cause the gun to kick Make sure you have a firm grip of gun and lance On completion of operation stop the engine Operate lance trigger Turn OFF water supply Release residual pressure in gun and lance by operating trigger When using Cleaning Agents A B Set machine up as for water Connect detergent hose to machine and place filter end into detergent On completion of work flush through hose and gun with clean water to remove any resid ual detergent NOTE CHEMICAL PICKUP ONLY OPERATES AT PRESSURES BELOW 250PSI OPEN LANCE VALVE FULLY TO OBTAIN THIS PRESSURE Step by Step Operating Manual Demon Hurricane P1 P2 P4 How to start the bee ipsa Hurricane Petrol Check gearbox oil and Check pump oil and replenish as requi
4. red replenish as required Check engine oil and Check petrol and To suck water from butt replenish as required replenish as required attach suction hose amp filter to machine Place filter in bucket or Attach trigger to high water source amp connect pressure hose hose to machine amp tighten If this is first use of the Pull the recoil to start day then switch the choke to the on position Step by Step Operating Manual Demon Hurricane P1 P2 P4 i coat ee i To ath off turn the Release any pressure in f i he engine button to the hose by squeezing running gently turn t off position trigger and disconnect choke to off position hoses from machine To transport ensure fuel is to the off position Max operating Operating Pressure Range 1500 psi 1000 1500 psi P2 2200 psi 1500 2200 psi 045 P4 2900 psi 2200 2900 psi 05
Download Pdf Manuals
Related Search
Related Contents
Montaje y modo de empleo Instruções para montagem e XC878CLM Series Errata Sheet Bedienungsanleitung Data Sheet Consultez ici la notice de la batterie ONE3. Delta Electronics Rectifier FR 2000 User's Manual ハローキティ あそびがいっぱいおりたたみジム 不適合事象公表区分内訳(H15/12/1∼H16/3/31) La gare LGV de Montauban - 20 villes moyennes témoins Copyright © All rights reserved.
Failed to retrieve file