Home
User Manual - Easy Glide Garage Doors in Derby
Contents
1. Auto close and Anti crash functions testing First open the barrier gate second press close button to close the barrier third put a metal thing over loop wire circles then the barrier will stop to close and open Then take the metal thing away the barrier will close automatically e Pressure sensor test First open barrier gate second press close button to close the barrier third press the rubber on the boom the barrier will stop close and open the barrier automatically 2 The do s and don ts during testing e Don t use it before testing www shiningsecurity com technical01 shiningsecurity com e Do cut off the power if the barrier gate is surrounded by water eDon t use it if the barrier has some faults such as abnormal sound boom broken spring broken And contact factory at once to replace broken parts eDon t let any person or any car passes the barrier when the barrier is closing eDon t let any person sit on or lean on barrier boom eDo close the barrier if there is a typhoon or thunder and lightning Trouble and Trouble removal 1 The boom shakes when it is on close or open positions eScrew loose Solving way Open the housing checking all screws And fix loosing screws eSpring is too tight or too loose Solving way Boom shakes on open position spring is too tight boom shakes on close position spring is too loose Just need to adjust the spring If the spring is out of normal shape or broken please do rep
2. Be sure that don t run the barrier before anchoring screw eUsing bolts and screws to fix boom with housing eConnect power according to wiring diagram then testing Notice All steps should be in power off situation Reference Picture Fan betimet 100 7 I Ts v A mv mv vw mv MN Rubber Can install pressure sensor 830 Arm support Optional Fixed by expansion bolt a Loop wire Concrete foundation www shiningsecurity com technical 1 shiningsecurity com 830 Fix base Dimension ST200 Dimension Test Instructions 1 Test All barrier gates have been tested in strict steps before leaving factory but transportation maybe causes some troubles So please follow the steps to check the barrier again eCheck wiring diagram to ensure all wire is well connected then connect power eCheck main board signal light is on or off If the light is off cut off power at once Then check all wires again to ensure all wires are well connected then connect power check it again e Use remote controller or push button to run the barrier and check boom s positions is on the right way or not If not amend the hall sensor till boom in its right position e Loop detector test
3. 10 The do s and don ts during testing 10 11 Trouble and Trouble removal 11 12 Using and maintenance Using INStuetions ee 12 M nen 12 NOtiCe 12 Guarantee card 13 www shiningsecurity com technical01Q shiningsecurity com Dear User Thanks for your trust Please read this user manual carefully before using shining barrier gates The manual includes main functions our own advantages dimensions parameters main board wiring diagram installation instructions testing and parts list The user manual can help you to know more details about shining barrier gate such as mechanical working theory using guide matters need attention We should use the barrier in right way to ensure the working life The user manual also analyzes some problems which maybe appear in the using process And you can find out the way to solve each problem in the manual At the same time we sincerely hope that you can give us some suggestions how to make our barrier gates to be more and more stable Thanks www shiningsecurity com technicalO 1 shiningsecurity com Our Advantages 1 Mechanical features e Integrative machine core all part
4. is made by mold so all parts can be more accurate And so the barrier gate can be much more stable eLeft or right installed can be amendable Customer can amend install direction by himself eAccurate link mechanism link mechanism can release boom s shake and motor load so the barrier gate can move more stable and barrier gate s working life can be more longer e70W turbine worm transmission deceleration induction motor Drive Steady Noise Lower Structures Compact can realize self locking eLock or open the boom by hand we can turn motor handle to lock or open the boom when power is of 2 Electrical features eHigh integrated level Powerful function eShutdown functions motor will be shut down automatically after 6 seconds and thermal protection functions can effectively protect our motor e Using hall sensors to control boom positions e Using imported high power relay to ensure power stability e Using imported photoelectric isolated protection circuit to ensure signals stability eintegrating Wireless remote control receiving module to ensure wireless controlling stability eUsing quench circuit to ensure main board working life eUsing imported Magnetic core transformer to ensure the machine s working in damping situation eMain board can provide power 12V 100mA to various limited switch 3 Safety features ePressure sensor Anti crash functions If the boom meets something during closing process the boom w
5. Remote controller distance 230m Communication interface RS485 Input interface optional 12V relay signal or2100MS pulse signal br www shiningsecurity com technical01Q shiningsecurity com 4 Housing structure ST200 Z T200 Q ST200 L Straight arm folding arm fence arm Can change between the three type freely The housing can be used both for straight boom folding boom and fence Sie www shiningsecurity com technical0 1 shiningsecurity com 5 Machine core structure ST200 series barrier gates uses turbine worm drive mechanism and bearing turning mechanism to control the boom movement And hall sensor can accurately control boom s vertical position and horizontal position ST200 series barrier gates can use 3m 4m 5m 6m booms We just need to change the hole to meet different boom length 1 2 3 4 3 6 7 8 9 21 22 We can amend arm s position via moving magnet 1 Hole for 6m boom 2 Hole for 5m boom 3 Hole for 4 5m boom 4 Hole for Am boom 5 Hole for 3m boom 6 Mechanical limited switch horizontal 7 Transmission shaft 1 8 Hall sensor 9 Spring shaft 10 Spring 11 Transmission shaft 2 12 Base to support shaft 2 13 Transmission shaft 3 14 Mechanical limited switch vertical 15 Support ba
6. amped guarantee card is valid 2 Guarantee is 1 year 3 Guarantee does not cover any problems caused by actions not following our user manual LAD WWW shiningsecurity com technical0 1 shinin gsecurity com Electrical Viring Diagram Motor Mortor Capacitor Limited Switch LIMITED SWITCH fewer o Falling Power i fenote Lifting Falling Limit mm Lifting Key GE Falling Key GH Stop key Vehicle Detector Socket Output Power Photocell p S ae alling limit O DC12V 1 lt 100m FT 5V COM Lifting limit Communication Module O ion TRAFFIC LAMP POWER op COM cL COM LRD LON N m Q O Q JO 3 gt gt gt gt ii Ik Q ER RE ES GS KE ET ED Copy or Delete key 4 EZ EEE GT asks FE vr Tor ga mn lt gt sis 28 S A ILE G amp ed 3 Sj 2 X 3 2 2 s 5 29 E e arth Wa ae 2 TRAFFIC LAMP prp 2 2 S e I cad o 5 2 le fe 2 8 S Power supply Connect to Serial ports of PC
7. etween machine core and housing eTransmission shafts is loose Solving way fix them 6 Remote controller cannot control the barrier eBattery is low power Solving way change a new battery eRemote controller receiver s wire is loose Solving way check all wires and fix them back if it is needed Using and maintenance 1 Using instruction e Do check power s voltage matches barrier or not Our standard is 220V 10 or 110V 10 e Press open button the boom will open to right position and stop ePress close button the boom will open to right position and stop e Power off just turn the handle of motor to open the boom Power on press close button then the barrier can be used 2 Maintenance eClean the housing surface regularly eCheck wiring diagram regularly if some wires loose fix them back ekeep the barrier in aeration drying atmosphere to ensure the stability and working life e Check transmission shafts regularly if loose fix them back eCheck spring regularly ensure spring is in good situations eCheck the connection between housing and grand regularly ensure housing is well fixed Notices 11 www shiningsecurity com technicalO 1 shiningsecurity com 1 Don t modify the barrier gates at will 2 Please keep the barrier close when there is a gale Guarantee card Customer Tel Address Purchasing time Model 1 Please write your information carefully only st
8. ill be opened automatically eLoop detector Anti crash functions If car stands under the boom the barrier gates cannot be close And the barrier gates will be closed automatically when the car passes the boom eOpen first functions no matter the boom locates any position it will be opened if barrier gate gets open signal ePlastic strips we can install plastic strip into our boom it can decrease accident damages 4 www shiningsecurity com technical01Q shiningsecurity com Dimensions and Parameters 1 Dimensions ead ihoia TETEE Boom length Speed Weight Dimensions M S KG MM ST200 ZM 6 6 38 330 232 972 ST200 ZH 4 5 4 38 330 232 972 ST200 ZK 3 5 1 5 38 330 232 972 ST200 ST200 QM 6 6 38 330 232 972 ST200 QH 4 5 4 38 330 232 972 ST200 QK 3 5 1 5 38 330 232 972 ST200 LM 4 5 6 38 330 232 972 Meanings of sub model Boom type Z Straight Boom Q folding boom L fence boom Speed type M 6s H 3s K 1 5s 2 Color available standard configurations Standard configurations Housing Color Door color Type A Blue silvery Type B Yellow silvery Type C Red silvery Type D Black silvery Notes color also can be customized according to customer s requirements 3 Parameters Power Supply AC220 AC110 50 60HZ Rated Power 100W Temperature 30 lt C lt 80 Weight 38 IP IP44 The height of boom support 830mm
9. lace new one eThe screw which connects transmission shafts is loosing Solving way checking the screws and fix it e Boom length doesn t match spring holes Solving way change spring holes according to boom length 2 Boom cannot close open to right position or barrier cannot be opened or closed e Barrier is in thermal protection situation Solving way if the barrier runs frequently and weather is too hot Barrier motor is too hot and maybe is in thermal protection situation At this time barrier cannot be open and close we just need to wait When the temperature is ok the barrier can be used normally e Main board is broken Solving way change a new board 3 Barrier opens and closes automatically e Wires to connect hall sensor are loose or fall off Solving way check wires and fix them back e Short circuit Solving way check wires and connect them in right way e Main board is broken Solving way change a new board e Hall sensor s magnet is not the right position Solving way amend the position 2102 www shiningsecurity com technical01Q shiningsecurity com 4 Boom cannot stand at right position eHall sensor s magnet is loose or wire connection is wrong Solving way amend magnet s position or reconnect the wires eTransmission shafts are loose or spring is too tight loose Solving way fix the shafts or amend the spring 5 Abnormal sounds eSyntony between machine core and housing Solving way set a rubber b
10. se 16 Hall sensor 17 Motor 18 Motor handle 19 Limited magnet vertical position 20 Limited magnet horizontal position 21 Green light open 22 Red light close 968 www shiningsecurity com technical01Q shiningsecurity com 6 Wiring diagram 6 1 How to connect remote controller with barrier gates First Press Learn button about 3 seconds green led light will turn on Second release Learn button Third press any button in remote controller till the barrier have relative actions Notice If main board doesn t get signal from remote controller within 8seconds main board will exit learn program 6 2 How to erase remote controller First Press Learn button about 9 seconds green led light will turn on Second green led light will turn off Notice After a period time using the control distance maybe be shorter Just check remote controller power we need to replace new power DC12V 23A And rain wind fog etc also can affect controlling distance it is normal Installation Instructions eOpen package and check parts accessories eChoose the right place to install the barrier gates please be sure that the foundation is concrete foundation and the angle between barrier housing and horizontal level is less than1 after installations eConnect power wire and signal wire with barrier gate advice that set power wire and signal in different wiring conduit eUsing expansion bolt and screw to fix the housing
11. www shiningsecurity com technical01Q shiningsecurity com Barrier Gate User Manual ST200 series ya SHINING TECH INC Version 3 Tel 86 755 89398806 Fax 86 755 89398986 E mail marketing shiningsecurity com gt www shiningsecurity com technical01Q shiningsecurity com Table of Contents Brief Description 3 Our advantages Mechanical features 4 Electrical features 4 Safety features 4 Dimensions and Parameters Bimenlansm a eee 5 Color available 5 ParameterS 5 Housing structure sms 6 Machine core structure 7 Wiring diagram 8 9 Installation Instructions 9 10 Test Instructions Test nnn nnn nnn nn nn ennnn non mm sene ennen sneen ennen nere