Home

Digital Signal Monitoring System Model IMEC16I User Manual

image

Contents

1. lead Note When connecting to the unit directly using a CAT5 cross over cable it maybe necessary to change your PC s IP address settings 3 2 Status Overview Once connected to the unit the status overview page will be displayed Overview Microsoft Internet Explorer provided by Carter Synergy Ltd DES gt e repice 68 0105 a EE FJA Ee w k overview B dey i Page J Tools i ox cec Overview Setup M EC IMEC16I IMEC 1 Input Name Status 1 Digital Input 1 FALSE 2 Digital Input 2 FALSE 3 Digital Input 3 FALSE 4 Digital Input 4 FALSE 5 Digital Input 5 FALSE 6 Digital Input 6 FALSE i Digital Input 7 FALSE 8 Digital Input 8 FALSE Digital Input 9 FALSE 10 Digital Input 10 FALSE 11 Digital Input 11 FALSE 12 Digital Input 12 FALSE 13 Digital Input 13 FALSE 14 Digital Input 14 FALSE 15 Digital Input 15 FALSE 16 Digital Input 16 FALSE IP Address 192 168 0 103 Software Version 1 1 CPC UK www cpcuk co uk Done Internet 100 SS Fig 3 0 Status overview page The status overview page displays the current status of all the unit digital inputs the unit name and the current IP address setting The toolbar at the top of the page enables includes an Overview link which reloads the status overview page and a Setup link which prompts the user to enter a username and password before displaying the unit configuration page The status overview page
2. Digital Input 10 TRUE FALSE 11 Digital Input 11 TRUE FALSE 12 Digital Input 12 TRUE FALSE 13 Digital Input 13 TRUE FALSE 14 Digital Input 14 TRUE FALSE 15 Digital Input 15 TRUE FALSE 16 Digital Input 16 TRUE FALSE Fig 3 4 Channel Settings Change Channel Settings Note When changing any of the unit settings the Change Channel Settings button must be clicked before the new settings will take effect For each channel the following settings maybe changed Name The name of the digital input as displayed on the overview page and within the XML status report Default Digital Input max 20 characters alpha numerical only True The state to be displayed when the input is active true as displayed on the overview page and within the XML status report Default True max 12 characters alpha numerical only False The state to be displayed when the input is in active false as displayed on the overview page and within the XML status report Default False max 12 characters alpha numerical only 12 4 XML Interface The XML interface enables third party alarm servers and management systems to read status information from the unit To read the XML status report the following HTTP request must be sent HTTP lt IP Address gt xmlstatus xml The following XML status report will be returned lt Status gt lt UnitType gt CPC UK IMEC 161 lt UnitType gt lt UnitNam
3. If you change this setting the current connection to the unit maybe lost Default 192 168 0 103 min 0 max 255 per segment The default gateway IP address normally left as 0 0 0 0 Default 0 0 0 0 min 0 max 255 per segment The DNS servers IP address only set if you are using a DNS server within you network Default 0 0 0 0 min 0 max 255 per segment The administrator password Default password max 20 characters alpha numerical only The unit name as displayed on the overview page and within the XML status report Default IMEC 1 max 60 characters alpha numerical only The digital input de bounce period the period in seconds that the digital input must have changed state for before the unit recognises the change Default 2s min Os max 30s If ticked the factory default settings will be reloaded with the exception of the IP address settings 11 3 3 2 Channel Settings The channel settings of the configuration page allows the user to setup each inputs name and the states to be displayed when the input is in active false or active true Channel Settings INPUT NAME TRUE FALSE 1 Digital Input 1 TRUE FALSE 2 Digital Input 2 TRUE FALSE 3 Digital Input 3 TRUE FALSE 4 Digital Input 4 TRUE FALSE 5 Digita Input 5 TRUE FALSE 6 Digital Input 6 TRE Fase 7 Digital Input7 TRUE FALSE 8 Digital Input 8 __ TRUE _ FALSE 9 Digita Input 9 TRUE FALSE 10
4. such as routers power supplies and signal conditioning devices this manual explains the features of the PCB only 2 Unit Hardware The IMEC16I includes the following hardware features Power Input Connector Digital Input Connectors 1 16 Ethernet Connector Battery Link Factory Reset Link Battery Link Inputs 9 16 INP9 INP10 INP11 INP12 INP13 INP14 INP15 INP16 SIVINIVIDVIVD OI VIDVIVOIV Ethernet Power In Q O O O O O O O G O eO eO e eO o e INPI INP2 INP3 INP4 INP5 INP6 INP7 INP8 Factory Reset Inputs 1 8 lt gt 133mm Figure 2 0 Layout 2 1 Power Input Connector J7 The power input connector J7 is used to provide power to the unit The unit requires a 12VDC power supply and should be connected as shown 12VDC GND Figure 2 1 Power connections 76mm Note The unit includes reverse polarity protection in case the user incorrectly connects the power supply 2 2 Digital Input Connectors 1 16 33 34 J5 and J6 The unit includes 16 digital inputs which are used for monitoring digital input signals in the form of volt free contacts Without any connection to the input the input is in active false If the input is connected to the 12VDC supply the input is active true Each input includes an LED which indicates the status of the input Input in active false LED not illuminated Input active true LED illuminated Each input connector prov
5. Unit 7 8 UK Heathrow Causeway Estate Ariel Way Hounslow VA Middlesex TW4 6JW 44 0 208 6302270 www cpcuk co uk Digital Signal Monitoring System Model IMEC16I User Manual Version 1 00 Software version 1 1 All rights reserved The information contained in this manual has been carefully checked and is believed to be accurate However CPC UK assumes no responsibility for any inaccuracies that may be contained herein In no event will CPC UK be liable for any direct indirect special incidental or consequential damages resulting from any defect or omission in this manual even if advised of the possibility of such damages In the interest of continued product development CPC UK reserves the right to make improvements to this manual and the products described herein at any time without notice or obligation Copyright Copyright by CPC UK No part of this manual may be reproduced or transmitted in any Form without express written authorization from CPC UK Trademarks All trademarks are acknowledged and are the property of their respective holders Contents Tntrod ction s an a a sasa saku Sah a a aq eA VENAE esas 4 Unit HardWarez u aaa ul qaa uay as bio eaaa Ta AAAA cacuedes brute Saat sit dees asas sskaku asss 5 2 1 Power Input Connector J7 nn nr 5 2 2 Digital Input Connectors 1 16 33 J4 J5 and J6 a 6 2 3 EtHERMetICONNECLON si u U ua skay ssia
6. a a Sy us stan as NTE 7 2 4 Battery kinkuu asus S SC M Sa b Sesia a Saa A ay ah 7 2 5 FaCtory Reset LINK u uuu asassssasasqquyusayqassqwpapatutuyauapasaayaphkaktapsqashasqptapyakusaqaqaa assas 8 Web Browser Interface wiccccsssscctensecccccssstesnueeececeseccataeneecedaersceastetatseaccaccusas tassheeedear acess 9 3 2 SATUS OVERVIOW 535 feces Eaderetee tes figeneeducecuncdasecuseugechagteceetsdsvactGadncuseedcadeeaesstetabenaisd ce 9 3 3 Configuration page sass cence Galedds apaa ae A a TEER e Ea SATER arana asai Taa TATEA 10 3 31 UNIT SENOS iine saanee a aa aa feds a aa aaar e a Nusa yaka A aani 11 3 3 2 Channel SettihgSiss it iina ua a aI aa N S 12 XML Interfaces ieuan aiaa eaaa AE Ea AEAEE qa ias ash TUENA 13 Seoli 1er i10 g AEA TTA T AA EAA T AAA A 14 HEEM aE Kol D AAE A TATAE AET E 15 1 Introduction The IMEC16I is a versatile fully configurable unit for monitoring digital input signals such as fault switches alarm relays position switches and level switches The unit includes an Ethernet 10BaseT interface enabling the unit to be connected to a TCP IP based network Information from the unit can be viewed using a standard web browser configuration of the unit is also achieved using a standard web browser A simple XML interface enables third party alarm and management servers to collect status information unit The unit is supplied in PCB only format but sometimes maybe supplied within enclosures containing other equipment
7. e gt IMEC 1 lt UnitName gt lt Report gt lt Input ID 1 name Digital Input 1 value FALSE gt lt Input ID 2 name Digital Input 2 value FALSE gt lt Input ID 3 name Digital Input 3 value FALSE gt lt Input ID 4 name Digital Input 4 value FALSE gt lt Input ID 5 name Digital Input 5 value FALSE gt lt Input ID 6 name Digital Input 6 value FALSE gt lt Input ID 7 name Digital Input 7 value FALSE gt lt Input ID 8 name Digital Input 8 value FALSE gt lt Input ID 9 name Digital Input 9 value FALSE gt lt Input ID 10 name Digital Input 10 value FALSE gt lt Input ID 11 name Digital Input 11 value FALSE gt lt Input ID 12 name Digital Input 12 value FALSE gt lt Input ID 13 name Digital Input 13 value FALSE gt lt Input ID 14 name Digital Input 14 value FALSE gt lt Input ID 15 name Digital Input 15 value FALSE gt lt Input ID 16 name Digital Input 16 value FALSE gt lt Report gt lt Status gt lt UnitType gt will always contain CPC UK IMEC 161 lt UnitName gt will contain the unit name as configured by the user lt Input ID will always show the relevant digital input channel number lt name will show the digital input channel name as configured by the user lt value will show the current digital input state as configured by the user Note An additional XML report is available wh
8. ich also displays the state of the factory reset input for testing purposes only HTTP lt IP Address gt xmlteststatus xml 13 5 Specification Dimensions 133 x 76 x 25 mm Power Supply 12VDC gt 250mA Digital Inputs 16 off 12VDC supply voltage sensing 1 off factory reset link Interfaces HTTP XML Communications Ethernet 10BaseT Operating Environment 32 F to 115 F 0 C to 47 C 0 to 95 Relative Humidity non condensing 14 6 Revision history 1 0 First draft of document 01 11 2007 15
9. ides a common connection connected via the PCB to the 12VDC supply connection and an input signal connection g N M st wo oO OOF OT OFT OF OT OF O FO FOarFoarFarFAaArFALFTALE AEA gt gt gt gt 5 gt 5 gt 5 gt 5 gt 5 gt 5 gt qanaoaoa nanaanqaognyraanan ZY ZY ZYY ZY ZYF ZY ZY 27 12VDC INPUT 1 12VDC INPUT 2 12VDC INPUT 3 12VDC INPUT 4 12VDC INPUT 5 12VDC INPUT 6 12VDC INPUT 7 12VDC INPUT 8 Figure 2 2 Digital Input Connections Input signals should be connected as shown VVIVQVIDVIGDVIDYIVDIVDVIVDD INP INP2 INP3 INP4 INPI INP6 INP7 INP8 ACTIVE IN ACTIVE TRUE FALSE Fig 2 3 Digital Input Examples Note If your application requires monitoring of other types of digital signals such as 240VAC signals external signal conditioning is required Contact CPC UK for more details 2 3 Ethernet Connector The unit includes a 10BaseT Ethernet network interface an RG45 connector located on the CPU core module enables connection of the unit to a network In a typical application the unit will be connected to a network hub switch or router using a standard CAT5 patch cable The unit may also be connected directly to a PC or Laptop using a CAT5 cross over cable Note The maximum cable length between the IMEC16I and other devices should be no more the 80m The CPU core module also incorporates LED s which shows the status of the Ethernet network connection Link LED Illum
10. inated when network connected ACT LED Flickers with network activity LINK LED ACT LED m S Contacts facing upward Fig 2 4 Ethernet Interface 2 4 Battery Link There is an onboard battery located underneath the CPU core module link JP2 enables and disables the battery During normal operation the link must be permanently fitted However if the unit it be stored for long periods of time it is recommended that the link is removed to pro long battery life QOIDVIVDOVIDVINVIGVINVIV Battery Battery Disabled Enabled Default Fig 2 5 Battery Link JP2 2 5 Factory Reset Link The factory reset link JP1 enables the user to reload the factory default software configuration To reload defaults Power off the unit Fit the factory link Power up the unit Wait 5 seconds Remove the link Factory default software configuration will now be loaded Normal Load Default Defaults OV ee WN VVIVQVIDVIV VIVID VIVVIVD Fig 2 6 Factory reset link JP1 3 Web Browser Interface The user may view input status and configure the unit using the HTML web browser interface 3 1 Connecting to the unit To connect to a new unit enter the default IP address in your web browser address bar Default IP Address 192 168 1 103 Note To avoid any IP address conflicts it is recommended that before the desired IP address settings have been set that you connect directly to the unit using a CAT5 cross over
11. t Name IMEC 1 De bounce period 2 Ei Reset all settings Channel Settings INPUT NAME TRUE FALSE 1 Digital Input 1 TRUE FALSE 2 Dinital Innit 9 Ti iz Teal ce l Done ee Internet 100 Fig 3 2 Configuration page The configuration page is divided into two sections Unit Settings and Channel Settings it maybe necessary to scroll down the page to view all the Channel Settings 10 3 3 1 Unit Settings The unit settings section of the configuration page allows the user to setup the network settings change the administer password etc Unit Settings Software Version IP Address Subnet Mask Default Gateway DNS Server System Password Unit Name De bounce period Reset all settings Change Unit Settings 1 4 192 ies fo fos 255 255 255s Jo o p p j o J fo fo password IMEC 1 2 Fig 3 3 Unit Settings Note When changing any of the unit settings the Change Unit Settings button must be clicked before the new settings will take effect Software Version IP Address Subnet mask Default Gateway DNS Server System password Unit Name De bounce period Reset all settings Read only displays the current software version of the unit The IP address of the unit If you change this setting the current connection to the unit will be lost Default 255 255 255 0 min 0 max 255 per segment The subnet mask
12. will automatically refresh once every 15 seconds 3 3 Configuration page The configuration page enables the user to setup software variables within the unit The unit is designed to be completely user configurable allowing the user to rename each input the input states unit name etc When accessing the configuration page the user will be prompted to enter the administrator user name and password Connect to 192 168 0 103 A The server 192 168 0 103 at engineer requires a username and password Default username admin User name admin Default password password Password eoccccee C Remember my password Fig 3 1 Password prompt Note The password prompt screen may vary depending on the web browser you are using If an invalid username or password has been entered the user will be prompted again to enter the username and password If a valid username and password has been entered the configuration page will be displayed System Settings Microsoft Internet Explorer provided by Carter Synergy Ltd Ge gt http 192 168 0 103 systemConfig cai v x le File Edit View Favorites Tools Help amp he System Settings h isp Page Q rE al Overview Setup IMEC IMEC16I IMEC 1 Unit Settings Software Version _ IP Address 92 ies fo fo Subnet Mask ass 2ss 255s o Default Gateway b Jo Jo Jo DNS Server pb p fo fo System Password password Uni

Download Pdf Manuals

image

Related Search

Related Contents

HLX-449  GE C2S985SETSS Use and Care Manual  BoConcept Istra Assembly Instruction  manual de instrucciones  Servomotores Síncronos CM / Instruções de Operação / 2003-01  OPaC User Guide Section1: Registration and Common Features  Printer Friendly Hillcrest X Series Owners Manual  Leia o manual em PDF  Manuel d`installation  