1. 10 20 Pool Line Pressure psig 30 Outlet Flow Rate Inlet Flow Rate 1 Based on your site assessment drill and tap a 1 2 BSP hole down stream of the pool filter and heater Note You can use saddle clamps if you wish This is one of two holes that will be needed in the installation The hole should be drilled on the side or bottom of the pipe if the pipe is horizontal NOT ALL PIPES RUN FULL 2 Cut both of the 12 x 1 2 PVC nipples in half 4 pieces Take one of the pieces and apply PTFE tape to the threads On top of the PTFE tape add a silicon seal bead around the threads The silicon seal helps to make a good seal Wipe off any excess 4 PTFE tape the 2 X 1 reducer bushing and screw and tighten it securely into the inlet of the Easiflo pump 5 PTFE tape the threaded end of one of the nipples that was cut in half Place a bead of silicon seal around the taped threaded ends 6 Screw and tighten the two pieces into the inlet and outlet of the Easiflo pump 7 Take the 1 ball valve and glue it onto the nipple that has been screwed into the pool piping in step 3 This is what makes the connection from the pool recirculation system to the Easiflo pump inlet using 1 2 PVC piping 8 Drill and tap another 1 2 BSP hole downstream of the first hole that was drilled and tapped This hole accommodates the
2. discharge side of the Easiflo pump If automated controllers are used in the system the drilled and tapped hole must be placed downstream of the auto control and pH probes location This is to avoid problems that may occur with the controllers operation See installation diagram Thread one of the cut 1 nipples into the 1 2 tapped hole 9 Take the 1 ball valve and glue it onto the nipple that has been screwed into the pool piping in step 8 Please make sure that there is a straight connection back into the pipe no elbows This is to connect the pool recirculation system to the discharge side of the Easiflo venturi 10 Tie in the electrical to the Easiflo pump making sure you have the pump configured for the correct voltage 10 11 Using 1 2 PVC piping connect the inlet side of the Easiflo pump to the 1 ball valve installed in step 7 using the plain x plain unions around the booster pump 12 Piping the discharge side of the Easiflo pump will involve installing a venturi and reducing tee See diagram on Page 10 for a reference Place and glue the 1 2 x 2 reducing tee and 1 2 plain x plain union on the 1 2 cut nipple on the discharge side of the pump This reducing tee will have a 2 male x male ball valve screwed into it that will provide the inlet water to the chlorinator 13 Take the black venturi and PTFE tape all the threaded ends Take the two unions makes for easy re
3. is insufficient to drain chlorinator A larger pump will be required to generate sufficient outlet flow Consult Arch 5 Now determine where the power source will come from for both the booster pump and solenoid These considerations will help determine the length and gauge of wire needed The last consideration for the site assessment is the fill tap water source and the type of pH control system to be used If Carbon Dioxide will be used for pH control it may be preferable to provide the inlet flow to the chlorinator from the fill water source Typically Carbon Dioxide pH control systems will raise the Total Alkalinity of the pool water to well over 100 ppm This TA level will increase the tendency for scale formation in the chlorinator Consequently it is recommended that the inlet flow be provided from the fill water source if the TA of the fill water is below 100 ppm The use of fill water to the chlorinator inlet will add water to the pool on a daily basis in relatively small amounts A typical indoor 375m pool will use approximately 75 litres of chlorinated solution from the Easiflo System per day A typical outdoors 375m pool will use approximately 227 litres of chlorinated solution from the Easiflo System per day The Easiflo 4 System also puts an additional 3 3m of water a day in the pool from the wash down system If you use this Installation method make sure that the pool has that amount of water being removed as to not cau
4. single pool installation can also utilise a venturi which employs the motive power of the pools own filtration pump However in this instance consultation with Arch Technical Services is necessary to advise on feasibility Multi pool installations as described below using the venturi and booster pump to evacuate the chlorine solution into the largest of the pools on site For additional smaller pools a conventional dosing pump can be used to take and inject chlorine solutions from the discharge tank of the feeder Ensure an adequately sized pump is employed Entry to the discharge tank can be gained by drilling an access hole close to the top of the tank ensuring the hole and subsequent suction line to the pump does not interfere with the discharge valve arm or float The dosing pump should be selected carefully realising that the chlorine solution produced is only around 1 5 of available chlorine Approximate sizing of pumps for different sizes of pools are as follows Up to 100ms 30 I h 100 200ms 501 h 200 300m 751 h Count 251 h for each additional 100m Instructions for Easiflo 4 Booster Pump Installation To simplify installation Please read this installation manual completely before going to the pool site Equipment needed to install Drill Cordless recommended Tube cutters or utility knife PVC pipe fittings as required Silicon thread sealant PVC Primer Cleaner
5. 2 pipe wrenches or gas pliers Channel Locks PVC Glue Water tight connectors for pump wiring Saw to cut PVC Pipe Wire for pump 14gauge minimum required Electricity for the pump 240V 15 Amp Pressure gauge 1 2 PVC pipe length will vary Saddle clamps optional PTFE tape Solenoid valve we recommend a In line filter we recommend a available from Prominent The following parts are included with the feeder Two 2 BSP closed nipples One flow indicator One female Parker tube fitting One line strainer W10FC8 54 One 2 BSP male x male grey ball One 2 BSP male x female grey ball valve valve 54 O D LDPE tubing 20 feet One male Parker tube fitting W10MC8 One Venturi Not included with the feeder A booster pump is not included with the feeder In order to get the optimal performance out of the feeder and the reliability from the pump we recommend the following pump Sta rite 1 0 HP pump reference SSP2RE1 available from SCP UK tel 01293 546 126 Alternatively Sta rite SP2REI can be used However for reliability we recommend the pump seal is changed to silicon carbide These seals have the part number 17304 0100 Overview A 1 loop is going to be added to the main pool recirculation line The loop will have an in line Easiflo pump to drive a venturi The Easiflo 4 inlet line will get water from the disc
6. e Easiflo pump or prior to the venturi if possible After the evacuation system has been laid out measure the height differential in feet between where the venturi will be installed and discharge valve of the Easiflo chlorinator Use this height differential to calculate the suction lift factor in the formula that follows The greater the height differential the more suction you will lose from the venturi Next calculate the outlet flow using F1 and the suction lift factor The minimum outlet flow required is 8 7 litres per minute Suction lift factor 34 height differential in feet 34 Example height differential is 6 feet therefore Suction lift factor 34 6 34 28 34 0 82 Take the suction capacity F1 and multiply it by the suction lift factor to get the actual outlet flow The formula is F1 x suction lift factor actual outlet flow Example 1 Assume that the pressure measured in the pipe is 12psi Using the P4 graph 1 in this manual the outlet flow F1 is determined to be 14 4 litres per minute F1 x suction lift factor actual outlet flow 14 4 It m x 0 82 11 7 lt m actual outlet flow This flow is acceptable It is above 8 7 It m which is above the minimum Example 2 Assume that the pressure measured in the pipe is 25psi Using the P4 graph the outlet flow F1 is determined to be 10 2 It m F1 x suction lift factor actual outlet flow 10 2 It m x 0 82 8 33 It m actual outlet flow This flow
7. g E4 only need 3 inch piece 71582 2 4014 Parker Fitting P6MC4 Q N 2 19 2003 Easiflo 4 Diagram Part Qty Description Number Number 73 72863 Discharge Valve Enhancement Adaptor 74 72865 Custom Washer for Discharge Valve Adapter 75 71576 Discharge Valve Gasket 2 19 2003 ISSUE 1 SPRING 2003 ARCH WATER PRODUCTS RESPONSIBLE CARE GUIDANCE NOTE S EMERGENCY RESPONSE PROCEDURE FOR ARCH WATER PRODUCTS CUSTOMERS In the event of a Health Safety or Environmental Emergency involving Arch Water products This includes e Injury to persons requiring medical treatment e Loss of containment of product to the environment e Involvement of the Emergency Services Police Fire Medical e Involvement of the Environmental agencies e Major damage to property FIRST TELEPHONE 44 0 1865 407333 This will connect you with the NCEC National Chemical Emergency Centre who support the Arch Emergency Response It operates 24 hours a day 365 days a year THEN Phone your local Arch Water Products Office during office hours 2 NCEC will provide initial assistance and advice in English NCEC will also contact Arch Water Products Head Office 4 When calling the Emergency No have the following information available use your Emergency Response Procedure Checklist e Your name e Your job title e Your company name and location e The Telephone and fax number that you can be contac
8. harge of the Easiflo pump The discharge valve of the chlorinator will be hooked up to the venturi The Easiflo pump provides the correct pressure 35psi to drive the jets in the manifold of the Easiflo 4 chlorinator It also provides correct flow through the venturi to create a vacuum to evacuate the chlorinator This installation method gives optimal performance of the Easiflo 4 chlorinator in most above and below grade installations The use of a pressure gauge on the discharge side of the pool pump after the filter is recommended for correct installation of the system Site Assessment Easiflo System Site Assessment It is critical to determine the effluent pressure of the system prior to installation This pressure must be measured immediately after backwashing when it will be at its highest level Refer to the appropriate system diagram in the back of this manual to determine where to measure this pressure P1 Take a pressure reading and refer to the graph on page 8 Easiflo 4 Installation 1 HP Booster Pump and 1585X Venturi to determine the suction capacity of the system assuming that there is no suction lift correction Record this suction capacity as Fl Next determine where the Booster Pump and Venturi loop will be installed Always minimize the backpressure on the venturi Avoid use of elbows after the venturi if possible Never install an elbow within 3 feet of the venturi outlet Always use elbows on the inlet to th
9. hth easitlo gt Installation Manual for the UK and Ireland Model 73179 Arch Chemicals Ltd ARCH Wheldon Road Castleford P West Yorkshire WF10 2JT 1 10 03 REV 7 Wa Tr ry Vi ATER CHEMIC Product Stewardship MAKING THE WORLD A BETTER PLACE Arch is committed to maintaining and improving our leadership in Product Stewardship One of the six initiatives outlined under the Chemical Manufacturers Association CMA Responsible Care Program is to make health safety and environmental protection an integral part of a product s life cycle from manufacture marketing and distribution to use recycling and disposal Successful implementation is therefore a shared responsibility Everyone involved with the product has responsibilities to address society s interest in a healthy environment and in products that can be used safely We are each responsible for providing a safe workplace All who use and handle products must follow safe and environmentally sound practices For more information about our Product Stewardship Program contact your Arch Representative SITE SURVEY When conducting the site survey and in discussions with the pool operator decide which type of installation will be carried out 1 A single pool installation should be carried out as described in the manual using the venturi and booster pump to evacuate the chlorine solution produced by the feeder into the circulation line of the pool A
10. moval of venturi for cleaning after Installation and screw one on each end and tighten Take and thread the 2 x 2 reducing union to the venturi 11 14 Connect the venturi as close as possible to the ball valve installed in step 8 using a 15 The recirculation loop is now complete short section of 1 2 PVC pipe Make sure the flow through the venturi is in the proper direction Connect the other end of the venturi to the discharge side of the Easiflo pump using 1 2 PVC pipe 16 Now hook up the Easiflo 4 feeder to the Easiflo recirculation loop Two 2 BSP grey ball valves have been included with the feeder One is a 2 x 2 male valve which is screwed into the reducing tee which is located on the discharge side of the Easiflo pump Once this is done thread on the line strainer NOTE Direction of flow arrow on line strainer assembly Next thread the 12 closed nipple into the line strainer assembly Install the flow indicator onto the closed nipple and then screw in the tubing connector 5 tubing x 2 MBSP into the flow indicator Connect the 5 tubing from the flow indicator to the solenoid valve inlet on the Easiflo 4 Plug the transformer into the controller or power source 115v See Easiflo 4 Installation Schematic layout in the back of the manual for clarification 17 The next 2 grey ball valve is a female by male valve Take the 2 and thread it i
11. n Number Number 3 71539 Emergency Shut Off Float Plate 38 71538 Emergency Shut Off Float Plate PVC Nut Discharge Arm Nut N 39 71540 Emergency Shut Off Overflow Float 40 71585 Discharge Valve Float 41 71615 Discharge Valve Body with Plug Ball amp Gasket 43 71584 Discharge Valve Arm with Suction Cup 44 71808 1 Easiflo 4 Pump 1 hp 45 71811 Venturi for Easiflo System 46 71907 Unions Quick disconnects Venturi Plain X Thread 47 71915 Manual for Easiflo 4 48 71621 1 2 Ball Valve MM Inlet 49 71605 5100A Line Strainer Assembly 50 71918 Parker fitting W10MC8 51 71547 1 1 2 X 1 2 Schedule 80 PVC T SXF 52 71892 Junction Body w Fittings 53 71921 Terminal Block 54 71922 Electronic Relay 55 71923 24V AC Transformer Plug US 56 71928 Gem Sensors Flow Indicator 155480 for Easiflo 4 only 57 71913 1 1 2 Slip PVC sch40 ball valves 58 71926 Power cord for Transformer 20 ft 59 71590 5023 1 2 X 3 8 Male Connector W6MC8 Parker 60 71911 Union 1 4 Threaded 61 71899 1 Washdown assmbly 2 1 4 clsed nipples 1 1 4 threaded Tee 1 3 62 71912 1 2 Threaded Tee 63 71916 1 2 PVC Closed Nipple 64 71891 1 20 Flexible Tubing 5 8 65 71627 1 2 Ball Valve MF Outlet 66 71917 3 4 FNPT X 1 2 FNPT PVC Reducer 67 71914 Quick Disconnects Pump Slip X Slip 68 71925 8 32X5 8 PVC Screws Packaged 4 69 71927 Briquette Cleaning Pan for Easiflo 70 72006 Parker Fitting W6MC4 71 71626 1 be 1 2 O D PE Tubin
12. nto the female side of the 2 ball valve This valve is threaded into the reducing bushing on the venturi Install female Parker fitting on ball valve Connect the 5 tubing from the venturi to the discharge valve of the feeder closed nipple 18 Restart the pool pump Open the 1 2 ball valves and start the Easiflo pump Run the Easiflo pump for 3 4 minutes Open the 2 grey valves and allow water to flow into the chlorinator checking for leaks 19 Refer to the Operators Manual for Easiflo 4 chlorinator operation 12 CO Acid Eductor Pump Flow From Pool Solenoid Chemical on unit Backwash Controller To Waste Recirculation EasiFlo 4 CHLORINATOR EasiFlo 4 Installation Schematic Layout 1 HP Pump amp Venturi Installation 10 20 03 Commercial Pool Products Standard Installation EasiFlo 4 Installation E4SS Flow From Pool Solenoid Chemical on unit Backwash Controller To Waste Recirculation EasiFlo 4 CHLORINATOR EasiFlo 4 Installation Schematic Layout 1 HP Pump amp Venturi Installation 10 20 03 Commercial Pool Products Optional Acid Feed FasiFlo 4 Installation E4SSA Acid Eductor Pump Tank N1 2 Tubing L p e ira Flow To Pool Chemical Controller Flow From Backwash To Waste PULSAR IV Installation Schematic Layout 3 4 HP Pump amp Venturi Installation 7 20 01 Commercial Pool Products Optional Pre Fil
13. se the pool to overflow Fill water systems typically operate at pressures between 50 80 psi This pressure is too high for the Easiflo System valves to operate properly It is therefore necessary to install a pressure regulator on the inlet flow to the Easiflo system This regulator must be installed directly at the fill water source This will insure a reduced pressure in the flexible polyethylene tubing and solenoid valve on the inlet side of the chlorinator Adjust the pressure regulator to provide between 30 35psi inlet water pressure See diagram below for proper fill water plumbing hook up Direction of Flow Inlet Shut Easiflo 4 off Valve Inlet Fill water Source Pressure Regulator 0 60 psi Pump The 1 H P pump is to be wired for 240V single phase service only The power supply to the Easiflo pump must be interlocked to the pool recirculation pump This is to prevent running the Easiflo pump dry when the pool pump is shut off Use watertight connectors when wiring the pump Installation of equipment Place the equipment pump and chlorinator in the poolroom in a convenient location Shut off the pool recirculation equipment before proceeding with the installation Review the installation diagram prior to installation Dealer Installation Notes Flow in GPM Easiflo 4 Installation 1 HP Booster pump and 1585X Venturi
14. ted on e The Product Name e The Product Code e The nature of the emergency e The action you have taken e Are the emergency services involved e Are the environmental agencies involved PLEASE ALWAYS CONTACT NCEC IN THE EVENT OF A HEALTH SAFETY OR ENVIRONMENTAL EMERGENCY INVOLVING ARCH WATER PRODUCTS BUT PLEASE ONLY USE THIS NUMBER FOR HEALTH SAFETY AND ENVIRONMENTAL EMERGENCIES as defined above
15. ter Installation PULSAR IV Installation PASSO WARRANTY POLICY Easiflo 4 Commercial Pool Chlorinator The Easiflo amp Chlorine Feeder comes with a 12 month warranty from the date of installation In order for the warranty to be validated the Warranty Registration Document W2 must be completed and returned to Arch Water Products Wheldon Road Castleford WF10 2JT Easiflo 4 Detailed View NA SF ZH IQ LY 4 Ng see detail B rev 01 15 03 i 9 9 Detail E Detail A Detail D D Detail B 10 ge gt D I a Kne gt rev 01 15 03 Detail C Rear Control Panel Detailed View to pool rev 01 15 03 Easiflo 4 Number Number 5 Hinge Rod for Easiflo 4 lid 0 n 12 Parker Fitting W8MC8 also for solenoid 13 71548 2 11 2 X 12 PVC Nipple E E 6 E E E A gt 5 Z x 7 x 29 1 drain valve true union With Nipple 3 E E 34 Emergency Shut Off Mounting Plate 5 36 71749 4 Plastic Screws 1 4 20 3 1 4 for ESV For Easiflo 4 Only 2 19 2003 Easiflo 4 Diagram Part Qty Descriptio