Home

A4-MWP User Manual.pub

image

Contents

1. very careful NOT to overfill chamber time needed to distil water can be reduced by using already hot or boiled water Place Fan Module onto Boiling Chamber making sure the silicone seal is correctly in place around the entire rim of Boiling Chamber Check to make sure the unit is on a stable surface Then connect the power cord from the Fan Module into the bottom of the machine Set up Collection Jug with Guiding Cap underneath water outlet nozzle and connect power cord to power outlet Press ON Button The fan will come on automatically and the tank will begin to heat thus starting the distilling process The ON button is used to start the machine only It can not be used to stop or turn off the machine prematurely before distillation is complete Water will begin to drip into the Collection Jug after approximately 30 minutes It will take approximately 3 5 hours to distil 4 litres of water The unit will automati cally shut down when the cycle has finished therefore you can leave it running overnight Important Do not use the first Jug of distilled water It will take one cycle for the unit to self clean Wipe out tank and rinse discard water in Collection Jug Distiller is now ready to create distilled water Please note The unit must be allowed to cool down before starting another distilling cycle Approximately 30 minutes The ON button will be inactive during this time Thi
2. replaced Power cable needs to be replaced No water in Boiling Chamber NOT MAKING ENOUGH DISTILLED WATER DURING CYCLE Water not filled to maximum full mark Water Collection Jug not correctly lined up with distiller via the Guiding Cap Distiller lid latex seal is not sealing properly and may need to be changed Water outlet nozzle not inserted correctly Please make sure it is placed under neath lower latex seal gt Sediment in the water outlet nozzle and the tube needs to be rinsed Please thoroughly read all directions relating to your distiller before operating Proper use care and maintenance will ensure a longer product life WARRANTY The Make Water Pure Stainless Steel Water Distiller comes with a one year parts and labour warranty to the original customer only Unless you have purchase additional warranty cover Your warranty information is stored on our system therefore we only require your order number or name and address Page 6 MAKE WATER PURE REFER A FRIEND We re offering everyone a 20 cash reward each time a friend is referred by you to our official website www makewaterpure co uk and purchases a water distiller REFER A FRIEND and receive a 20 cash reward when they buy a water distiller That means for example if you refer 5 friends and they all purchase a water distiller you ll receive 100 cash Visit www makewaterpure co uk refer a friend for more infor mation W
3. ATER DISTILLER ACCESSORIES You can purchase accessories for your water distiller such as additional jugs residue cleaner and carbon filters direct from our website www makewaterpure co uk buy FOLLOW US ON SOCIAL MEDIA f y We are on Facebook and Twitter just search Make Water Pure and like or follow our page HELP AND ADVICE WITH YOUR DISTILLER If you have any questions regarding setting up or using your distiller you can contact by email info makewaterpure co uk or via Live Chat available on our website make weterpure Page
4. amber Holding the metal nozzle push the Fan Module away from the nozzle until it clips out use force to do this without worry of damaging as it can appear stiff Remove and discard the used carbon filter and replace with a new one You should rinse soak and gently squeeze all new Carbon Filters in a glass of water preferably distilled before using to help remove excess carbon Do this until the majority of the excess carbon which will appear grey is greatly re duced in the glass of water Page 4 INSTRUCTIONS TO ASSEMBLE THE GLASS JUG You will need the glass jug handle 2 metal straps and a screwdriver To remove the stainless steel top from the jug twist anti clockwise Glass Jug Plastic Handle 2 x Metal Straps Screwdriver STEP 1 STEP 2 Align the jug handle adjacent to the jug Screw the bolt through the metal strap and pouring outlet Next wrap one of the metal plastic handle until it is fixed tightly Repeat straps around the jug as shown below the process on the bottom of the handle The jug lid is used The Guiding Cap is used to to keep the jug g d y help align the jug with the sealed filter nozzle during distillation Page 5 TROUBLESHOOTING NOT MAKING ANY DISTILLED WATER ON button has not been pressed in Main power cord is not plugged into power point or Fan Module cord not plugged into base of the distiller No power from electrical outlet Fuse in power cable needs to be
5. ill automatically turn off when cycle is finished To stop unit mid cycle remove power cord from socket The ON button is not used to stop the machine mid cycle Leave power cord unconnected when unit is not in use Do not remove Fan Module whilst unit is mid cycle Wait until unit has cooled down before removing Fan Module Do not place anything that will obstruct the top of the Fan Module Page 1 Open the packaging you will see the water distiller which is divided into two parts the Boiling Chamber and Fan Module Take them out of the packing box and then lift up the Fan Module and take out the glass collection jug from the Boiling Chamber Unpack the Water Distiller and check all the components are present and undamaged The box should contain the following 1x Boiling Chamber 1x Fan Module 1x Collection Jug Glass or Polycarbonate 1x Jug Guiding Cap 1x Jug Lid 2x Jug Handle Straps Glass jug only eee 1x Filter Already installed 1x Residue Cleaner 1x Jug Handle Glass jug only Wate rpure co Wa 1x Power Lead UK EU US aa es water distiller M ep out of reach of ch Page 2 SETUP PLEASE READ THE BELOW SETUP INSTRUCTIONS BEFORE USING THE MACHINE Place the Water Distiller in a ventilated room on a flat dry surface such as your kitchen worktop Lift off the Fan Module and fill Boiling Chamber inside of the machine s body up to the FULL line using tap water while being
6. make Waterpure WATER DISTILLER USER MANUAL PRODUCT SAFETY PLEASE READ THESE INSTRUCTIONS BEFORE OPERATING THE APPLIANCE AND RETAIN THEM FOR FUTURE REFERENCE gt This product is not suitable for use by children and may not be suitable for per sons requiring supervision unless they receive instruction by a competent person on how to safely use the product Children should be supervised to ensure they do not play with the product Never use this appliance for anything other than its intended use This appliance is for indoor use only Do not use this appliance outdoors Always ensure that hands are dry before handling the plug leads or switching on the appliance Always use the appliance on a stable secure dry and level surface in a well ventilated area Ensure that the appliance is switched off and unplugged from the supply socket before assembling or disassembling Never let the power cord hang over the edge of the worktop touch hot surfaces or become knotted trapped or pinched Do not use this appliance if it has been dropped or if there are any signs of visible damage This appliance must not be placed on or near any potentially hot surfaces such as a gas or electric hob Never immerse any part of the appliance or power cord and plug in water or any other liquid Keep the body of the unit dry only fill with water using a jug Pressing the ON button will begin distilling cycle and unit w
7. s will prevent injuries from scalding water and prolong the life of the Distiller Page 3 CLEANING REMOVING RESIDUE Once Distiller has cooled down rinse and wipe out tank everyday using clean water The interior of the stainless steel vessel is smooth Never use abrasive cleaners on your dis tiller e g steel wool or steel soap pads After each cycle rinse the inside of the Boiling Chamber with clean water and remove the lose scaling with a nylon dish brush Calcification and scale will build up on bottom of the Boiling Chamber and should be re moved every two weeks Use following instructions to do this Pour in enough hot water to cover scale in the tank at least 1 litre Pour 1 4 teaspoons of Residue Cleaner into Boiling Chamber depending on the amount of scale DISCONNECT AND REMOVE FAN MODULE and start a cycle by pushing ON button Let cycle run for 30 minutes only before turning the machine off at the wall then carefully pour out hot water and wash the inside of tank with clean water lfscale is not completely removed then repeat the process IMPORTANT Do not allow all water to fully boil and evaporate out of the chamber This will hap pen if you forget the machine is on and leave it running over 30 minutes REPLACING ACTIVATED CARBON FILTER Pull metal nozzle out to replace the Carbon Filter gt Replace Filter in filter nozzle every 2 3 months Lift Fan Module off from Boiling Ch