USER MANUAL - Daray Medical

image

Contents

1. 10 Wall mounted lamp Assembly the wall holder to the wall according to instructions given in Instruction for building preparation for installation of operation and examination lamps Assembly the supporting mars system to wall holder fig 5 Assembly the head of the lamp to spring arm fig 4 _ 4 fig 5 Assembly of the arm to wall holder Wall holder Supporting arm Washer Ending of lamps arm Cover Mobile lamp Remove the mobile base cover screws fig 6 Feed the mains and steering wires through the hole in the mobile base sleeve fig 6 Assembly of the battery backup cover Battery backup cover Screw M3x25 DIN 963 Screw M3x6 DIN 963 Fit the upstand into the slot in the mobile base Ensure the slot in the upstand engages the corresponding keyway in the base fig 7 12 fig 7 Assembly of the lamps stand Stand Moveable base of the lamp Leasing pin Output of the wires fig 8 Assembly of the screw blocking the stand Secure the upstand with the screw fitted from beneath the base fig 8 Stand assembly washer Washer A10 DIN 127 Screw M4x6 DIN 963 Connect the mains and control wires Assembly the mobile base cover screwing the screws fig 6 Assembly the head of the lamp to spring arm fig 4 Connect the mains wires After assembly of examination lamp one should connect the po
2. Control panel Lamp suspension arm 1 6 Design characteristics The SL300 Illumin8 minor surgery light is designed for ceiling or wall mounting or as a mobile lamp device The lamp is designed to ensure excellent colour rendering high intensity and uniform distribution in the operating field Suspension of the lighting fittings and the handle on the lamp ensure stable and easy positioning adjustment during operation The SL300 is supplied with a variable focus controlled by the removable auto claveable handle 1 7 Safety Following the guidelines and instructions included in this manual assures safe operation and use of the product lamp may only be used for the purpose for which it is designed as specified in section 1 1 Incorrect operation of the lamp operating principles could be hazardous Failure to observe the instructions in this manual could result in a hazardous situation and may invoke the product warranty The lamp is not designed for use in hazardous environments When the lamp is turned on do not look at the front part of the lamp as glare effect may occur Do not use the lamp when the occulters or optical filter system indicates failure i e unstable fastening cracks etc There is a considerable disturbance of temperature conditions and change of light characteristics which can largely affect the medical procedure NOTE Changes in the optical system incorporated in the lamp
3. If the customer resigns from further using the product he will be responsible for disposing of the product in accordance with the provisions of the Environmental Protection 22 5 Electromagnetic Environment Characteristics Electromagnetic emissions Medical product SL300 Illumin8 minor surgery light is designed for use in the electromagnetic environment with the following specification The User should ensure that the medical product SL300 Illumin8 minor surgery light is used exactly in this kind of environment Type of emission Classification Explanations and guidelines The medical product SL300 Illumin8 minor surgery light generates RF energy only for internal needs required by the RF emissions Group 1 equipment to work CISPR 11 p The level of the RF energy emission is very low and it is unlikely to cause any interference with the near electronic equipment RF emissions Class B CISPR 11 Harmonic emissions IEC 61000 3 2 The medical product 5 300 Illumin8 minor surgery light is designed for use in habitats and in rooms directly i connected to LV network which feeds residential buildings Voltage fluctuations Compliant w lal building flicker IEC 61000 3 3 23 Electromagnetic immunity The medical product SL300 Illumin8 minor surgery light is designed for use in the electromagnetic environment with the following specification The User should ensure that the medical produc
4. are not be eligible for credit We will accept returns and exchange for the correct item If you purchase an item incorrectly you can return it within 14 days and it can be exchanged for another product of equal or high value excluding transportation charges incurred If you send us goods that do not qualify for return you will invalidate your claim to any refund and you will be obliged to compensate DARAY Ltd for the cost of return postage and any other reasonable costs incurred processing the goods Your statutory rights are not affected 26 WARRANTY TERMS AND CONDITIONS OF WARRANTY To qualify for this warranty you must register on www or return to Daray Ltd Daray the duly completed warranty registration form accompanying the product Daray warrants this product excluding lamp against faulty material and workmanship during the period of the warranty The period of warranty is the period stated on your warranty card and commences on the date of purchase of the product In the event that the product is not in good working order Daray will provide during the warranty period a free repair service within the United Kingdom The warranty is subject to proof of purchase being provided therefore you should retain your original receipt 2 1 The repair service consists of the provision of spare parts and or replacement products at Daray s discretion which will be provided on an exchang
5. for fraud b Under the Consumer Protection Act 1987 to a person who has suffered damage caused by a defective product or to a dependant or relative of such a person c Direct damage to your property caused by the proven negligence of Daray This agreement does not give any rights other than those expressly set out above and in particular Daray will not be responsible for any loss of income profits or contracts or any direct or indirect consequential loss damage caused to or suffered by the purchaser as a direct result of this agreement This warranty is offered subject to these terms and conditions in addition to and does not affect your statutory rights Daray may disclose your details and other personal information to companies within the Daray group including any subsidiary company or sub contractor of Daray for the purposes of performing our obligations hereunder You must not resell outside the UK any products supplied by Daray and covered by the Export of Goods Control Order 1992 or any law that replaces it with out obtaining all necessary licences You also agree not to sell the product in the UK if you know or think that the person buying the product intends to export it without getting the necessary licences You agree to impose similar conditions to these on anyone you sell the product to 10 These conditions shall in all respect be governed and construed in accordance with English law and the exclusive ju
6. humidity 30 to 80 Air pressure 700 hPa to 1060 hPa 1 3 User s responsibilities The user must ensure that the product is used only for the purpose for which it is intended and that it is used in the conditions for which it is designed and according to these instructions The user must undertake all the necessary measures to ensure safe operation of the product The product should only be operated by qualified personnel properly trained and familiar with these instructions The user must ensure that all persons using the product should read understand and follow these operating instructions 1 4 Technical Data 35 000 5000 Ix 50 000 5000 Ix 96 1 90 1 OPERATING FIELD DIAMETER 13 19 2 cm COLOR TEMPERATURE 4200 200 K 189 W m 2132 W m2 OPERATING RANGE WITHOUT FOCUSING 70 140 cm POWER SUPPLY 230V 50 60 Hz LIGHT SOURCE Halogen lamp 22 8 V 50 W LAMP LIFE 1300 h ILLUMINATION CONTROL 50 100 LIGHT INTENSITY COLOR RENDERING INDEX Ra IRRADIATION INTENSITY EE AT ECMAX 1 5 Description of the elements and functions gus 4 1 Light head 2 Autoclavable adjusting handle 3 Lamp positioning arm 4 Lamp suspension arm gt Wall mounting 7 amp PA 5 2 1 4 _ y fig 2 SL300M Illumin8 minor surgery light Light head Autoclavable adjusting handle Lamp positioning arm Stand
7. in the arm holder Carefully read the operating instructions of the product Perform the initial start up of the product according to the description provided in section 2 3 Installation and start up Before beginning with installation of the lamp with the suspension system visually check the delivered product This applies in particular to cracking of the optical filter system and lamp covers and autoclavable handle fastening The SL300 is supplied by the manufacturer disassembled Depending on the model the SL300 consists of the following parts e 51300 light head supporting arms system ceiling mounting system e SL300W head of the lamp supporting arms system wall holder e SL300M head of the lamp stand and mobile base Assembly of above mentioned parts should be performed according to given instructions Ceiling lamp Assembly the ceiling plates according to instructions given in Instruction for building preparation for installation of operation and examination lamps Assembly the supporting arms system to ceiling mounting system fig 3 Assembly the head of the lamp to spring arm fig 4 fig 3 Assembly of supporting arms system to ceiling fig 4 Assembly of head of the lamp to spring plate arm Ceiling plate Masking cover Supporting arms system Screw blocking the covers Nut M12 PN 86 M 82144 Washer A13 DIN 125 Washer Al2 DIN 127 Protecting plate Ending of lamps arm
8. reflector optical filter and bulb are unacceptable changing the type of the optical system elements will result in loss of light properties of the lamp Do not install any foreign elements not supplied by Daray on the lamp case inside the lamp on the clamping arm system as this may destabilize the suspension system and pose additional hazard when performing the operation e Avoid collision with both the clamping arms and the lighting fixtures Multi collisions may result in damage and loss of proper technical parameters by the lamp NOTE During lamp operation do not touch the front occulters The glass may heat up to a high temperature which may cause burns 1 8 Electromagnetic compatibility Medical product SL300 Illumin8 minor surgery light is an electrical device Electrical devices are the source of electromagnetic radiation and are affected by it However the SL300 operates from 50Hz mains and is neither a significant source of EM radiation nor is likely to be significantly affected by it 2 Shipping and start up 2 1 Shipping The product can be shipped by any commonly available covered type means of transport During transport the unit should be protected from moisture and locked in place The product should be transported under the following conditions Temperature 10 C to 60 C Relative humidity 20 to 80 During transport storage and unpacking of the product the temperature change may not be great
9. the repair list supplied with the Guarantee Card of the product The user should carry out technical checks every 6 months according to the table below The scope of technical check Checking correct connections and protections in the rotary points adjusting the pressure of friction brakes which ensure stable operation of the suspension system Checking the electrical safety visual inspection of the insulation condition of the power leads Supporting arms Checking by visual inspection the technical condition of the handle surface no cracks scratches etc sterilised handle Checking proper functioning of the securing mechanism of the sterilised handle Checking the front polycarbonate panel no cracks scratches etc Light head Checking correct functioning of the control systems control panel sterilised adjusting handle 4 8 Troubleshooting 21 The list of repairs which can be performed by the client on his own Fault Possible cause Remedy Lamp does not light No power Check the lamp power supply system Bulb does not light Blown bulb Replace the bulb with a new one Intensive use of the Tighten up with commonly available product constructional spanners Insecure fastening of the Damaged cracked sterilised handles handles Loose bolts Replace the handle with a new one If the fault cannot be removed place the product as out of order and contact the repair division
10. DARAY gt SLSOO Ceiling Wall and Mobile Version INSTALLATION AND OPERATING MANUAL OPERATING INSTRUCTIONS USING THE SL300 GENERAL REQUIREMENTS USER S RESPONSIBILITIES TECHNICAL DATA DESCRIPTION OF THE ELEMENTS AND FUNCTIONS DESIGN CHARACTERISTICS SAFETY ELECTROMAGNETIC COMPATIBILITY A A NnNN OR RR SHIPPING AND START UP 2 1 SHIPPING UNPACKING AND INITIAL START UP INSTALLATION AND START UP CONTROL PANEL ON OFF SWITCH HANDLE CONTROL POSITIONING CORRECT OPERATION ASSESSMENT CRITERIA TECHNICAL SUPPORT 4 1 STORING 4 2 WASHING AND DISINFECTION 4 3 CHANGING THE LIGHT BULB 4 4 BATTERY CHARGING RELATES TO MOBILE 4 5 FAILURES AND DEFECTS 4 6 REPAIRS AND MAINTENANCE 4 7 TECHNICAL INSPECTIONS AND CHECKS 4 8 TROUBLESHOOTING ELECTROMAGNETIC ENVIRONMENT CHARACTERISTICS RETURNS POLICY WARRANTY WARRANTY REGISTRATION Tel 0844 375 9000 Fax 0333 321 0973 email info daray co uk url www daray co uk 1 OPERATING INSTRUCTIONS 1 1 Using the SL300 The SL300 Illumin8 minor surgery light is designed for illumination of the operating area when carrying out diagnostic therapeutic and cosmetic procedures 1 2 General requirements The product is designed for indoor use Required climatic conditions Temperature 10 C to 40 C Ambient temperature change over 8 hours not greater than 20 C Relative
11. ch can cause damage to network structure of the plastic elements organic solvents Failure to comply with the above requirements will void the products guarantee 4 3 Changing the bulb 18 Only original spare bulbs supplied by Daray may be used Using other bulbs may lead to reduction of light intensity and adverse changes in optical and heat parameters Halogen bulb life is approx 1300h Bulb must be changed in the following sequence e turn off the lamp e unscrew the cover item 1 fig 7 Caution After turning off the lamp the light head internal structural elements and bulbs can remain hot Fig 14 Bulb holder cover 1 unscrew the knurled screw item 2 fig 9 remove the bulb holder item 3 fig 89 Do not touch the new halogen bulb with bare hand To grab it use the original package or clean material 1 mount the new bulb item 5 fig 15 supplied by Daray Ltd in its socket item 4 fig 15 2 Tighten up the cover proceeding in the reverse sequence 19 Fig 15 Bulb holder 4 4 Battery charging SL300MB The power supply adapter incorporated in the mobile base houses the battery backup device The power supply module is switched on by connecting the power lead and turned off by disconnecting it Caution The lamp must be connected to the power supply according to the rating plate Do not use the power supply lead when it is faulty or the insulation is damaged Do not connect the lamp in a
12. e basis and will either be new equivalent to new or reconditioned All replaced spare parts and products shall become the property of Daray 2 2 Daray s only obligation under this warranty is the provision of the service as set out above 2 3 All products are returned to Daray at the customer s cost and risk Products to be returned should be adequately packed For the address to send returns to please visit www daray co uk Daray s arrangements for providing service provided under this warranty may include the use of sub contractors This warranty does not cover damage or defects the Product caused by or resulting from e Wilful neglect or negligence by anyone other than Daray Improper use storage or handling of the product e Use of non Daray approved parts such as replacement lamps not compatible with the Product e Fire accident or disaster e Use of non Daray modifications other than in accordance with Daray s instructions Attachment of fittings and accessories not approved by Daray Repairs modifications carried out by service personnel not approved by Daray e Damage caused by chemical corrosion from cleaning agents not approved by Daray e Failure to use or install the product in accordance with the manufacturer s instructions Nothing in this warranty shall have the effect of restricting or excluding the liability of Daray in respect of a Death and personal injury caused by the negligence of Daray or
13. er then 10 C during one hour The product can be unpacked only after reaching the temperature of the room where the product is located When the difference between the temperature of the room where the product is located and the shipping temperature is considerable the product should be left for min 12 hours Only after this time the device can be started This product should not be stacked Should it be necessary to ship the product under different conditions especially when shipping under low temperatures it is necessary to prior arrange with the manufacturer the shipping method and type of package to ensure safe Transport 2 2 Unpacking and initial start up The lamp is supplied by the manufacturer as a disassembled unit in a cardboard box The lamp should be unpacked inside the building to protect it from being damaged In order to prepare the lamp for service after delivery or shipment e remove securing tapes e remove the cardboard cover Remove transport packing from the lamp Packing waste is recyclable material and should be disposed of accordingly The packages may have the following markings reusable package recyclable package 4 LDPE low density polyethylene package t Fasten the lamp clamping arm system according to the lamp version spring arms allow to adjust the angle of deflection and tension the deflection angle and tension adjustment system is located below the removable arm casing Secure the lamp
14. following information carefully The DARAY Ltd returns policy provides guidance on when you can return goods we have supplied and what you can expect from us once you do To see our detailed returns policy and procedure visit www daray co uk returns TYPE OF RETURN REMEDY DAMAGED GOODS OR DOA Goods which are physically damaged on must be notified within 24 hours of receipt delivery or which do not function GOODS DEVELOPING A FAULT soy 14 days of delivery we will replace the item as Goods which have developed a fault within the warranty period If the fault develops after 14 days but within the warranty period we will initiate the returns procedure NON WARRANTY Goods which have developed a fault outside the warranty period OTHER Any situation which is not covered by the above If a fault develops outside the warranty period we will initiate the returns procedure We will try to help but we cannot normally offer a refund DOA dead on arrival For additional clarification please refer to our terms and conditions at www daray co uk terms In a small number of cases we may determine that a replacement would not work any better than the original product we supplied In such cases we will only offer a refund rather than a replacement for qualifying returns Replacement bulbs are not eligible for returns unless they are faulty or damaged Spare parts ordered on our website or from supplied part codes
15. medical product SL300 Illumin8 minor surgery light is designed for use in the electromagnetic environment with the following specification The User should ensure that the medical product SL300 Illumin8 minor surgery light is used exactly in this kind of environment munity Conducted 3 Vrms 3 Vrms Interference induced by RF fields IEC 61000 4 61150 kHz to 80 MHz Electromagnetic RF field IEC 61000 4 3 3V m 3V m 800 MHz to 2 5 GHz Explanations and guidelines Portable radio communication appliances should not be used within a distance shorter than the recommended separation distance determined based on the corresponding formula depending on the transmitter frequency This distance is a distance between the transmitter and any part of the medical product or and its wiring Recommended separation distance d 1 21 P d 1 2 P 80 MHz to 800 MHz d 2 3 P 800 MHz to 2 5 GHz Where P is a maximum power output of the transmitter in watts ON according to the declaration of transmitter manufacturer d is a suggested distance in meters Intensity of the fields generated by stationary RF transmitters determined based on measurements taken at the installation site should be less than the level of immunity of The column within the whole frequency range b Malfunctioning of the medical product can occur when using the column near the equipment marked with the following symbol The user should check correct functioning of
16. mp 2 Check if there is no mechanical backlash when moving the lamp and the arm 3 Check functioning of the electronic system by executing all movements controlled from the control panel and the sterilised handle If the lamp passes the tests described above and if during the functional movements no distressing sounds creaking rasps are observed then the product can be safely used Otherwise refer to section 5 7 Troubleshooting If the product is not fully functional i e the obtained parameters deviate from the specification provided in these instructions do not attempt to operate it If this is a case report it to the manufacturer or the supplier dealer NOTE Using unserviceable product may lead to consequent damage with expenses charged to the user and for which the manufacturer assumes no liability 1 4 Technical Support 4 1 Storing If the product is not going to be used for long time store it under the following climatic conditions q m Temperature 125 100 10 C Relative humidity 50 25 4 2 Washing and disinfection When washing and disinfecting use washing agents which do not contain bleaching agents active oxygen or chlorine After disinfecting the product must be washed out with distilled water to eliminate weeping Using too much water can lead to flooding the interior of the lamp After disinfecting dry the product completely Dry it with hot air max temp to 60 or by wiping wi
17. pad The lamp is turned on by pressing the on off button located on the front panel of the light head 2 6 Handle control Lighting field magnitude can be adjustable by turning the autoclavable adjusting handle fig 11 item 1 a Se fig 11 Autoclavable adjusting handle e Toremove the handle fig 11 item 1 press the lock button fig 11 item 2 and while holding it down pull the handle downwards e To install the handle slide the handle fig 11 item 1 onto the guide until the latch locks in place Before each use check if the handle is undamaged and is properly fastened In case of any malfunction replace the handle 15 2 7 Positioning Light head positioning is done using the autoclavable adjusting handle fig 11 item 1 Lamp height is adjusted by moving the suspension arm fig 12 and 13 It is possible to adjust the arm tension To reduce the tension arm rises insert the adjusting bar located below the removable casing in the hole and rotate clockwise If the tension is too small arm drops rotate the adjusting bar anti clockwise fig 12 Adjusting the arm tension for SL300M fig 13 Adjusting the arm tension for and SL300MB SL300W and SL300C 16 3 Correct operation assessment criteria The product should be checked for correct functioning before its first start up on the particular day Correct operation assessment procedure 1 Check if the lamp moves smoothly by manually moving the la
18. reas presenting risk of explosion In order to charge the batteries connect the mains lead to the power supply network 230V 50 60 Hz Connection to the power supply is indicated by green LED on the control panel The batteries are charged automatically The charging process is signalised by the orange LED lit on the control panel fig 4 item 6 The total charging time is approx 12 hours the charging time can be extended without any harm to the batteries When the orange LED goes off fig 4 6 the battery is still being charged If after 12 hours of charging the orange LED is still lit on the control panel indicating the charging process this means that the lamp is broken Proceed further as per section Repairs and maintenance Nominal operating time of the lamp when supplied from the batteries is 2 hours with the batteries fully charged The battery life period 15 5 years The batteries should be replaced as a whole set two batteries replacing only one battery will result in shorter operation time of the lamp and quick using up of the new battery 4 5 Failures and defects Damages and defects detected in the lamps must be reported without delay to the responsible person The product which cannot be safely operated ex damaged electrical or mechanical components cannot be used until it is repaired 4 6 Repairs and maintenance 20 Repairs must be carried out by the manufacturer or an authorised repair centre The user ma
19. risdiction of the English courts 27 28 ON Gvidas 39 130 JLOONMGAVMS SINDIEIN 9199 4911 YINS IALIIIA 01 YSIM JOU OP pue pry eseg Aue 0 uo ssed IM AVYVO enads JNO Inoge NO puas 01 PINOM AYYVa 220 O91S SXDA SVHH SNId 18odaa y IVINA ANVANOOD 656 3INVN JAVIYILIV NOI9 AVaIVa MMM LV AT13AILVNHIFSLTY SSIH00V 1S0d3343 HMO OL AdOTSAANS 10 Y NI INV 19078 NI F3LFIANOI ALNVHHVYM gnoA ALVONVA OL AW ya NOILVALSIOSG Marquis Drive Moira Derbyshire DE12 Tel 0844 375 9000 Fax 0333 321 0973 email info daray co uk url www daray co uk
20. t SL300 Illumin8 minor surgery light is used exactly in this kind of environment IEC 60601 1 2 Immunity Test level Immunity level Explanations and guidelines The floor in the place of using the product should be made of wood ee 6 kV contact concrete or covered with ceramic tiles If the floor is covered with synthetic IEC 61000 4 2 8 kV air 8 kV air material the relative humidity should be minimum 30 1 kV between the 1 kV between Feeding line the Feeding line conductors conductors The mains specification and existing Surges interference should be such as in IEC 61000 4 5 2 kV between the 2 kV between typical commercial or hospital feeding line the feeding line environmental Conductor and conductor and ground ground 2 kV feeding lines kV lines feeding The mains specification and existing interference should be such as in 1 kV signalling 1 kV signalling typical commercial or hospital Series of fast lines lines environmental lt 5 UT gt 95 dip UT for 0 5 cycle Voltage drops 40 UT 60 dip The mains specification and existing collapses voltage fluctuatlons In UT for 5 cycles interference should be such as in feeding lines typical commercial or hospital g 70 UT 30 dip environmental IEG BEE UT for 25 cycles lt 5 UT gt 95 dip UT for 5 secs NOTE UT is a mains voltage before applying the test voltages 24 Electromagnetic immunity The
21. th a soft sterile cloth Autoclavable handle Removable adjusting handle item 1 fig 6 is made of material resistant to high temperature sterilisation conditions The handle must be washed cleaned disinfected and sterilised before the first use and before each next use Make sure to use for washing cleaning and disinfection only the agents which are intended for this purpose The handle should be sterilised in autoclave at a temperature up to 134 C for max 5 minutes During sterilisation observe the parameters specified by the autoclave manufacturer The lamp must be cleaned and disinfected immediately after its use Washing cleaning and disinfection operations should be to carried out according to the instructions of the manufacturer of agents used paying particular attention to the agent concentration method of carrying out the operation and recommended disinfection time Only handles which have been prior cleaned and disinfected can be sterilised The handle should be sterilised in standing position due to possible collection of water inside the component The handles can be sterilised maximum 1000 times after this time the handles should be replaced with new ones Light head supporting system Plastic dishes should be washed cleaned and disinfected CAUTION The light is not waterproof 1 Do not use bleaching containing active chlorine or oxygen caustic or corrosive agents 2 Do not use agents together with plastics whi
22. the medical product when being used near the equipment marked with this type of symbol 1 Intensity of the fields generated by stationary transmitters such as radio and telephone stations wireless cellular telephony ground mobile radio stations amateur radio stations AM FM transmitting stations TV transmitters cannot be estimated with sufficient precision In order to evaluate the electromagnetic radiation generated by stationary RF transmitters it is necessary to conduct measurements in the place of installation of the medical product SL300 8 minor surgery light If the electromagnetic field strength value in the place of installation of the medical product exceeds its immunity level then correct operation of the product should be verified If the medical product is not functioning properly then it may be necessary to take additional measurements change the orientation and or location of the medical product and or take additional protective measures Outside the range of 150 kHz to 80 MHz the field intensity should be less than 3 V m The above explanations may not be applicable to all cases Propagated electromagnetic waves are absorbed and reflected from buildings objects and people 25 Returns Policy IMPORTANT Before returning your item you must call us on 0844 375 9000 We want you to be completely satisfied with your purchase If you need to return goods purchased from DARAY Ltd please read the
23. wer supply lead to mains 230V according to Instruction for building preparation for installation of operation and examination lamps Check the light operates in accordance with the functions defined below Ensure all controls operate smoothly Do not put the product into service unless it operates properly in accordance with this manual The manufacturer will not accept liability for any outcome whatsoever from customers assembly or use of this product where the content of this manual has not been fully observed Use and operation 2 4 Control panel Section 3 1 refers to mobile version of the lamp fig 2 fig 9 Layout of the function keys on the control panel The control panel is located on the stand After connecting to the mains the green LED 2 lights The lamp is switched on by pressing the button I 1 Lamp parameters are set using buttons 3 and 4 which can be used to control light intensity within a range from 50 to 100 Ec The lamp is switched off by pressing the button 1 Indicator 5 shows the battery charge state and the LED lighting up next to the indicator 6 indicates battery charging process LED indicators on the control panel meaning lamp power on lamp power off indicates the battery charge level battery charging in progress 14 2 5 On Off button Section 3 2 relates to models without the control panel fig 1 fig 10 Light head version without control key
24. y not carry out any repairs or modifications to the product In order to assure safe and reliable operation of the product use only original spare parts supplied by the manufacturer The used parts must be disposed off in compliance with the applicable environmental protection provisions This product contains components which may be dangerous to the environment Methods of disposal of used products which may be hazardous to the environment are governed by the waste disposal provisions If the batteries need to be replaced the used batteries are collected by the medical equipment manufacturer or the authorised repair centre indicated by it Repairs and maintenance must be carried out only by qualified personnel 4 7 Technical inspections and checks To ensure safety and proper technical condition of the product within the whole period of product serviceability the product must be subjected to periodical technical inspections performed at the user s expense by the manufacturer authorised repair centre or Client s authorised trained technical personnel Only the satisfactory result of the inspection may form the base for further use of the product The user must perform periodical technical inspections according to the table below Scope of the inspection Frequency checking the functionality and general technical condition according to the service instructions every 12 months Technical inspections should be recorded on

Download Pdf Manuals

image

Related Search

Related Contents

26 novembre 1884  Kraftstofftrolley 53 l mit Zapfpistolenpumpe  Instrucciones de servicio  2. Guía de usuario para la realización del trámite de obtención de  Smoke NV AU E-Shisha Kit Manual 2015-10-14  z50 INSPECTOR z30 DETECTOR  Document  Half Facepiece Respirator 6000 Series Respirateur à demi  Samsung SM-T2105 User Manual  IMD-C Series - Autic system AS  