Home
User Manual - Sussex Alarms
Contents
1. 4 51 6 B 7 81 9 C lt Amo we area C D amp 5 lt gt 2 Y x T ow to navigate through the menu s I NO Press to move forward when the user mode Press to move backward when in the user mode YES Press to enter in a submenu or option when in the user mode Press to move from one option into another option while in a submenu Press to quick exit the user menu from any main menu written in capital letters CANCEL Press to move back from one programmable option to the previous option Moves forward in the main menu and sub menu Exits option to sub menu and sub menu to main menu Main menus are indicated with capital letters and end with a question mark for example CHANGE CODES The sub menus are indicated with small letters and they also end with a question mark for example Learn codes tags keyfobs Programmable options are indicated with small letters and do not finish with question mark but Yes No or other options are offered In order to navigate in the menu system one has to answer to the questions in the main and sub menus For example if the question is CHANGE CODES Pressing YES will bring you in the sub menu Learn codes tags keyfobs Pressing YES will take you to the programmable options of this submenu Pressing will take you out of the individual option
2. Action If Latch Output O Put 01 Output 1 Show Status m B 170 79 Keyfob Output 1 10 p 7 Select Button e ini iip 1 Button LOCK oir atch Output 1 2 Button UNLOCK E x LA Sumon 5 Timed Output If Timed Output iOutput Open Time Output Open Time 3 Button 030 0 250 seconds 4 Button 5 Buttons LOCK UNLOCK 6 Buttons Il 7 8 Press C Key to DELETE code Press and Hold ANY button for 5 seconds until LEDs flash Buttons LOCK Buttons UNLOCK II W Pyronix www pyronix com 15 5 Master Manager Menu Review Logs Event memory _ REVIEW LOGS gt Panel Log gt 01 01 00 11 44 21 34 iRepeat all 2 714 Start of Log Alarm Silenced Events 2 D E SSS Mmmm A x x C x Y plo obtain more information on the event m m m ms Press LC lt 3 E 2 gt z H Access Ctrl Log 01 01 00 11 44 E713 i Repeat for all Z i Start of Log I Useropen Door 2 Events 5 4 ERA 244554
3. Y ATO obtain more information on the event Press 5 5 WPyronix www pyronix com 6 Master Manager Menu SMS Phonebook SMS Number 1 1 Y WALK TEST User Mobile 7 Do not use NOTE Number 1 is normally reserved for ARC communications SMS PHONEBOOK Numbers 2 3 4 is normally reserved for SMS messaging Before you change this function please consult your installer 7 Master Manager Menu Walk Test ABCD x x 01 Walk Test Inputs Input 01 BELL TEST 8 Master Manager Menu Bell Test 1 BELL TEST 7 Testing Bell PC MENU WPyronix 17 www pyronix com 9 Master Manager Menu PC Connect Menu _ PC CONNECT MENU 7 Select PC to ra Select Operation Calling Remote FA dial 1 Connect to PC 0 7 Select to Dial Select Operation 111 PC Modem 1 0 Connect to PC 2 PC Modem 2 1 Test Dial 3 PC Modem 3 2 RM Service 4 PC Modem 4 8 Data from PC
4. 50131 1 2006 4 1 2009 7 50131 3 2009 50131 6 2008 wireless technology EN50131 5 3 2005 A1 2008 Security Grade 2 Environmental Class II INTERNAL SIREN WARNING The Enforcer 32 WE control panel contains a 100 dBA siren please be aware of W e this when in use VP0IHIg IrKX RINS1503 4 www pyronix com Software Revision V9 01 Contents Page A Introduction 3 B Keypads Readers 4 C Using the Keyfob 5 D Arming the Enforcer 6 E Disarming the Enforcer 7 F Arming disarming with the tag reader 8 G Arming disarming for Entry Control 8 H Chime Feature 9 I Personal Attack From Keypad 9 J Fire Alarm From Keypad 9 K Master Manager Menu Options 10 1 Master Manager Menu Bypass Fire PA 11 2 Master Manager Menu Operate User Automation Outputs 11 3 Master Manager Menu Configure Date amp Time 12 4 Master Manager Menu Change Codes Configure user codes learn tags and keyfobs 13 5 Master Manager Menu Review Logs Event memory logs 16 6 Master Manager Menu SMS Phonebook 17 7 Master Manager Menu Walk Test 17 8 Master Manager Menu Bell Test 17 9 Master Manager Menu PC Connect Menu 18 10 Master Manager Menu Allow Engineer Menu 18 11 Master Manager Menu Block Remote Arm 19 12 Master Manager Menu Block UDL 19 13 Master Manager Menu Exit Master Menu 20 M Engineer Contacts and Table 21 N Input Tables 22 O User Tables 24 P Outputs 25 Q Product Info
5. 4 Data to PC 5 Diagnostics 6 Commissioning v ALLOW MENU 10 Master Manager Menu Allow Engineer Menu _ ALLOW ENGR MENU 2 Allow Engr Menu Yes 1 lt BLOCK REMOTE ARMING 18 W Pynonix www pyronix com 11 Master Manager Menu Block Remote Arm BLOCK REMOTE Block Remote Arm x ARMING No 0 x a g BLOCK 0017 12 Master Manager Menu Block UDL _ _ UDL 2 Block UDL 0 EXIT MANAGER MODE WPyronix www pyronix com 13 Master Manager Menu Exit Master Menu EXIT ENGINEERS MODE x BYPASS INPUTS Enforcer 32WE Time 0 25 OR BYPASS INPUTS 32WE Time 0 25 Press the A key to exit Engineers mode from any main menu item displayed in capital letters 20 W Pyronix www pyronix com M Engineer Contacts and Table Alarm Company Date of Installation Site Reference Engineer Name Engineer Contact Number Installed to Grade 2 Environmental Class Other Comments WPyronix 21 www pyronix com Input Tables www pyronix com W Pyronix 22 N Input
6. 31 101 CHANGE CODES 12 W Pyronix www pyronix com 4 Master Manager Menu Change Codes Configure user codes learn tags and keyfobs 4 1 Change Codes Configure User Codes Press C Key to DELETE code E gau ee CHANGE CODES 2 User Codes Tags p Empty 01 iZ Enter User Code iZ p User Type i ZL User In Area iZ Learn Keyfobs NORUNT AE E i 12 User 0 de ABCD 2 0 eee mm 0 s Wk x x x x lt x x User Type 0 User 1 Manager User Options Area Arm Choice LZ Ly i User Name 0 cM 4 x User Arm Options Arm Choice x 0 Disarm Arm 0 No 1 Disarm Only 1 Yes 2 Arm Only 3 None 7 g
7. tag Use keyfob qJ 218 3190 A EE 2 4 5 6 14111514 61 Le JJ 7 81 9 x Lo v ps x 2 Lv p www pyronix com E Disarming the Enforcer Enforcer 32 User Enter Your Code 7 Disarm Areas 7 Enforcer 32WE Arm Area A Code ABCD Time 02 53 C Deselect the Area s to be disarmed Enter your code Present your tag Use keyfob s some sem m m SWE like 1 x s AJ S 37 M s Lal sj le 5 6 Le lt z 91 c lt x 5 Fa x ieli gt WPynonix www pyronix com F Arming disarming with the tag reader If you have a tag reader installed then it will be possible to arm and disarm the alarm sys
8. will move you up from one sub menu to the next sub menu or back to the main menu LEFT GREEN LED After a valid tag is presented the GREEN LED will illuminate indicating the power status e Tag Area Where you present your tag to arm disarm Ready LED Ready to arm Alarm LED Shows alarms Tamper LED Shows tamper alarms Alert Pending Fault LED Shows system faults Disarm LED Shows system disarmed W Pyronix www pyronix com C Using the Keyfob The wireless keyfob has four buttons that may be programmed for specific functions no action show status arm area disarm area latch output timed output and PA alarm activation Locking the Keyfob All four buttons on the keyfob may be locked to prevent from a user accidentally pressing them Locking the keys on the key fob is performed by pressing any buttons that are diagonal with one another at the same time LOCK amp II or UNLOCK amp I The RED LED will flash indicating that the fob has been locked To unlock press both buttons together again and the GREEN LED will flash indicating that the key fob is now unlocked NOTE When the keyfob is locked all indications are also disabled Buttons The buttons can be customised to operate as desired programmed in the function Change Codes Below are examples on how each button can be programmed amp BUTTON Programmed for Area When presse
9. Tables Wired Inputs 71 ai 2 22 52 RIXAddress2 53 RIXAddress2 EC OOOO T y 56 RIXAddress2 1222 20 02 s7 RIXAddress2 SSCS 2212 20 20 RIXAddress2 OOOO aa E rr j j _ ________________________ _ 00011110 WPyronix www pyronix com 23 O User Tables Code Tag Keyfob Code Tag Keyfob a o um gt x 5 i www pyronix com 24 Wired Outputs tatced Timed t e 00000 PeMi Onboard Stth Onoar O O OO O LL BELL Onboard Pemi ROX 2 ems LL PSMA ROX __ ______ o o 0000000 ooo PGMi3 ROX 000 ooo 00 Pemz mo LL PGMi4 O O O Oo LL WirelessOutputs tatched Timed Type OOOO a see oS y lt sea 7 7 C W Pyronix gt www pyronix com Q Product Information For electrical products sold within the European Community At the end of the electrical products useful life it should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice in your co
10. X m lo 2 j 2 K Master Manager Menu Options Bypass Inputs Disables any sensor input on the system for the current arming period This feature also disables tamper alarms Operate User Outputs Activates deactivates user automation outputs that are used to activate remotely the devices such as electronic gates lights etc Date amp Time Programmes the date and time and enables the summertime automatic adjustment Change Codes Programmes the user codes tags and learns keyfobs to the Enforcer 32 WE Review Lo The Review Logs function is used to view all operational information of the alarm system such as arming disarmin g information access control and alarm activations etc SMS Phonebook If SMS texting is enabled there will be up to 4 mobile numbers that can be programmed to send SMS alarms Please discuss this feature with your installer if required Walk Test The Walk Test function allows the testing of all programmed inputs on the alarm system Bell Test This function is used to tests the external siren wired and wireless and strobe PC Connect Menu The control panel may be dialled into and programming information kept on a PC using the InSite UDL software This function allows the control panel to dial a Pre programmed PC telephone number programmed by
11. d one or more areas will be armed af BUTTON Programmed for Disarm Area When pressed or more areas will disarmed I BUTTON Programmed for Latch Output For example when pressed a gate can be opened When pressed again a gate be closed II BUTTON Programmed for Status LED For example when pressed the system status is shown RED Armed GREEN Disarmed ORANGE Fault Quick Arming If one of the buttons is programmed as Arm Area the alarm system can be armed by the keyfob The keypad will then start to count down the exit time depending what the exit mode is programmed by the engineer Once the alarm panel is in this arming stage it is possible to quick arm the system by pressing the same button again this will reduce the time of arming and therefore making the system arm immediately The disarm LED on the keypad will turn off and a beep will be heard once the system has been armed and the RED LED on the keyfob will be illuminated for a short time NOTE Quick arming cannot be used when intelligent arming is enabled W Pyronix 5 www pyronix com D Arming the Enforcer Enforcer 32WE User Enter Your Code 7 Arm Areas 2 Please Wait Z Time 02 53 E ABCD Arming Wireless Deselect the Area s User not needed to be Code armed Stop Arming Stop Arming ABCD Y Enter your code Present your
12. rmation 26 R Notes 27 T ick start th tem only th featur to b rogramm www pyronix com A Introduction Two Way Wireless Security Protect Your Family and Property Without Compromise The Enforcer 32 WE is a wireless alarm system that has been designed with your security in mind with quick and easy installation and minimal maintenance the Enforcer 32 WE protects your home with a multitude of unique features Taking full advantage of Pyronix s innovative two way wireless technology the wireless devices on the Enforcer 32 WE system are constantly communicating with each other using the Pyronix High Security Wireless Encryption Protocol The Enforcer 32 WE two way wireless devices are fully operational when the system is armed making your system more secure compared to other wireless systems where devices are disabled for up to five minutes after every activation to save battery therefore compromising your security The Enforcer 32 WE has been engineered by Pyronix as a secure reliable and easy to use wireless alarm system It includes the following features Battery Monitoring Savin The Enforcer 32 WE system uses advanced technology to preserve the battery life of each wireless device However the Enforcer 32 WE informs you when a battery needs replacing a month in advance before the device stops working This key feature gives you enough time to change the battery in the specific device Other wireless alarm systems may no
13. s etc via your keypad or remotely via your Keyfob extending the use of your security system SMS Text Notifications The system will notify you via SMS text messages in real time For example notification that your child has returned home from school safely or notification of a leakage of water in your property etc W Pyronix i www pyronix com Keypads Readers Disarming Meth Exit user menu Select area A Moves backwards to the previous main menu item Selects area B Displays additional information in the log Scrolls to previous option in a sub menu Selects Used for Fire and PA alarms There are three different devices that may be used in the process of arming disarming the alarm system these are the keypad tag reader and keyfob Moves forward in the log Selects area D Directional buttons used for choosing options and moving through text Selects items and enters menus 1 Armin i Button Operations 1 2 3
14. t Master Manager 7 User In Area gt User Options H 7 p Area Arm Choice z Code _ I Siete ABCD Disarm Arm 0 LU x lt User Arm Options LX Area Ar p ol x 0 Disarm Arm s 1 Only n 2 Arm Only Hl Yes 9 None lt Y Y Y User 212 g REVIEW LOG W Pyronix 13 www pyronix com 4 2 Change Codes configure proximity tags Press C Key to DELETE tag 1 Y pjEnter Type z Y p User In Area 1 Zh Learn Keyfobs 3 PC Dh UT d ABCD User Type 0 User 1 Manager Present tag User Arm Options 7 p Area Arm Choice 2 p User Name iz m 9 ere ee x gt x x User Arm Options Area Arm Choice 0 Disarm Arm 0 No 1 Disarm Only 1 Yes 2 Arm Only 3 None v v v M Pyronix www pyronix com 4 3 Change Codes learn configure keyfobs User Codes Tags Learn Keyfobs Enter User Code User i 2 Green Red Select Button Button Action 1 E If Arm Area User In Area i L gt Status _ i Disarm Area Button Action 0
15. t give you a low battery warning signal meaning that devices could stop working leaving your environment unprotected Intelligent Arming This feature enables the control unit to automatically recognise when you re at home or away and arms itself in the correct mode without you having to choose User Friendly Keyfobs The fully two way wireless keyfob allows you to see the status of the control unit via 3 colour LEDs System armed When the system is armed a RED LED will illuminate momentarily System disarmed When the system is disarmed a GREEN LED will illuminate momentarily System fault When the system is in fault condition an AMBER LED will illuminate momentarily This will also flash when the keyfob is unable to arm the system It is possible to allocate different functions to each keyfob such as arming disarming different areas activating outputs to control external devices such as gates requesting system status and activating panic alarms Up to 32 wireless keyfobs can be added to the Enforcer 32 WE system Each wireless keyfob has its own user ID which can be reported to the ARC and user mobile phone which are stored into the event log of the control panel individually The keyfob also allows you to arm disarm every area individually giving you total control of your system User Automation Outputs The Enforcer 32 WE includes user automation outputs that give you the option to operate up to 20 devices such as gates lights sprinkler
16. tem using a tag Disarmed Armed Disarmed G Open doors Arm and Disarm Entry Control A tag reader can also be used to unlock entry doors 2 Z O 000 5 B 20 211 5 Disarmed Locked Armed Disarmed Locked Armed Armed A Arming Present a valid tag to the reader the GREEN LED will illuminate on the external reader remove the tag the door will unlock then present the same tag wihthin 10 seconds and the system will arm and the door will lock Disarming Present a valid tag to the reader and then remove it the status will be shown the alarm symbol will illuminate indicating the system is armed onthe internal reader and the RED LED on the external reader present the same tag wihthin 10 seconds again and the system will be disarmed and the door will unlock Access Control The readers can be used also for opening doors only without the ability to arm and disarm Please contact your installer for more information on this feature 8 W Pyronix www pyronix com H Chime Feature The chime feature can be used on door contacts to enable a chime so
17. und when a door input is opened This feature can be set up by your installer To disable the chime on the keypad close all doors and when c is displayed press the key a capital C will be displayed this will then activate the chime on any additional keypads with extension speakers installed If you wish to disable the chime altogether press the C key again NOTE Chime should not be used on motion detectors as this will drain the battery I Personal Attack From Keypad If an PA alarm is needed press and hold both the 1 171 keys or hold 12 for 3 seconds and alarm will be generated Note The PA facility needs to be enabled by your engineer either silent or full alarm Please note that the key fob can also be programmed to support a PA alarm Please discuss this with your engineer J Fire Alarm From Keypad If a fire alarm is needed press and hold for seconds and a alarm will be generated Note The Fire alarm key need to be enabled by your engineer Enforcer 32 Time 28 35 EE EX EX Ne E
18. untry When disposing of the product and accessories the batteries must be removed and disposed of separately in accordance with the local regulations 26 W nix www pyronix com 27 WOd x udJAd MMM UlO2 XIUOJ d MMM 93ISq9M fibojouu 3y s3 3 um om
19. your engineer This is usually used by your engineer during a maintenance call NOTE Pressing the A key will exit the master manager menu at any main menu option above These features are needed to quickly set up the Enforcer NOTE Make sure you change the default master user code x M Pyronix www pyronix com L Entering the Master Manager Menu Enforcer 32WE Enter Code BYPASS INPUTS Default Master r 1234 Time 02 53 C 1 Master Manager Menu Bypass Fire PA _ BYPASS INPUTS zb Bypass Input 7 Bypass Input Input 01 Choose Input 01 to 66 USER OUTPUTS 2 Master Manager Menu Operate User Automation Outputs Select Output _ USER Z 2 Output Off 2 Output On 7 OUTPUTS x Turn Ouput On Off 01 4 Show Current Ouput Status lt Select User Automation Output 01 Output 1 19 Output 19 rg DATE amp TIME WPyronix www pyronix com 11 3 Master Manager Menu Configure Date amp Time DATE amp TIME 1 31 Hours 0 23 7 01 23 i i Summer Time Adj No 0 Year 00 99 07 Month 1 12 Minutes 0 59
Download Pdf Manuals
Related Search
Related Contents
SVX8004 IP PBX System User manual - stephen Praktischer Leitfaden 2015 für private Postsendungen Interphone for Apartment Unit Samsung MM-DS80 User Manual SE”,ES T2 Additional Function Manual SP4.3 取扱説明書 充電式全ネジカッタ SC101D 工場電気設備防爆指針 労働安全衛生総合研究所技術指針 : Free Download, Borrow, and Streaming : Internet Archive 米子東 (PDF494キロバイト) Copyright © All rights reserved.