1. Copyright 2007 Extech Instruments Corporation All rights reserved including the right of reproduction in whole or in part in any form 6 EA11A V1 0 02 07 erlgum This datasheet has been downloaded from www EEworld com cn Free Download Daily Updated Database 100 Free Datasheet Search Site 100 Free IC Replacement Search Site Convenient Electronic Dictionary Fast Search System www EEworld com cn All Datasheets Cannot Be Modified Without Permission Copyright O Each Manufacturing Company
2. Approximately 110 hours with carbon zinc batteries 32 to 122 F 0 to 50 C 8096 RH 14 to 140 F 10 to 60 C 7096 RH up to 2000 meters COME 150x72x35mm Approx 8 29 oz 235g with battery Units Range Accuracy 23 5 C O F to 1832 F 0 3 reading 2 F F 58 F to 0 F and 5 s 0 5 reading 2 F 1832 F to 1999 F 0 C to 1000 C 0 3 reading 1 C C 50 C to 0 C and 0 5 reading 1 C 1000 C to 1300 C Tembaratirs 0 1 times the applicable accuracy specifications per C from COSE 0 C to 18 C and 28 C to 40 C 32 F to 64 F and 82 F to 104 F Note Temperature accuracy does not include the accuracy of the type K probe Note The temperature scale is based on the international temperature scale of 1990 ITS90 EA11A V1 0 02 07 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment a six month limited warranty applies on sensors and cables If it should become necessary to return the instrument for Service during or beyond the warranty period contact the Customer Service Department at 781 890 7440 ext 210 for authorization or visit our website at www extech com for contact information A Return Authorization RA number must be issued before any product is returned to Extech The sender is responsible for shipping charges freight insura
3. User s Guide EXT INSTRUMENTS EasyView K Type Thermometer Model EA11A EXTECH f eese _ Introduction Congratulations on your purchase of the Extech EasyView Thermometer This device offers a single K type thermocouple input with multifunction LCD display This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Safety To prevent personal injury or meter damage use the meter only as specified in this guide WARNING To avoid electrical shock or personal injury do not apply more than 20Vrms between the thermocouple inputs or between the thermocouple and earth ground Meter Description Meter 1 Thermocouple input connector a ee pe Tm Ot ooo 2 LCD display El Bg BB BAAR 3 Function buttons 4 Battery compartment rear Display Low battery Primary display Memory location Auto power off Secondary display 2 Max Min and Average Temperature units 3 Read from memory location Store to memory location 5 Hold Offset aoB Q oO mB oO NS O 2 EA11A V1 0 02 07 Operation Connecting thermocouples 1 This meter accepts any K type thermocouple with spade plugs sub miniature type with one spade wider than the other 2 Plug the thermocouple into the meter s thermocouple input jack Measuri
4. nce and proper packaging to prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of specification improper maintenance or repair or unauthorized modification Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct indirect incidental or consequential damages Extech s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Calibration and Repair Services Extech offers repair and calibration services for the products we sell Extech also provides NIST certification for most products Call the Customer Care Department for information on calibration services available for this product Extech recommends that annual calibrations be performed to verify meter performance and accuracy Lond Y Support line 781 890 7440 Technical Support Extension 200 E mail support extech com Repair amp Returns Extension 210 E mail repair extech com Product specifications subject to change without notice For the latest version of this User Guide Software updates and other up to the minute product information visit our website www extech com Extech Instruments Corporation 285 Bear Hill Road Waltham MA 02451
5. ng 1 Press the button to turn power on The meter will perform a short self test 2 Press the C F button to select the desired temperature unit of measure A display icon will reflect the selection 3 Ifa probe is not connected to the meter the indication will appear on the display 4 Contact the object to be measured with the probe 5 Read the measured temperature in the display Note If the display indicates OL the temperature is outside the measurement range Maximum Minimum and Average Function 1 Press the MX MN button to capture the Maximum MX Minimum MN and Average AVG temperature values 2 The lower secondary display will appear with MX and the maximum recorded temperature displayed The upper display will continue to measure the current temperature The lower display will update only when a new higher temperature is measured 3 Press the MX MN button to step through MX MN and AVG 4 The AVG value is the true average of the measured values Averaging will occur for 4 hours then the average will reset and begin a new 4 hour cycle 5 To exit the MX MN function Press and Hold the MX MN button until the display returns to standard operation Note The Auto Power Off feature is disabled when the MX MN feature is selected Data Hold Press the HOLD button to freeze the reading in the display The H icon will appear on the top center of the display Press the HOLD button again to return
6. on the LCD when this feature is enabled To disable the feature 1 With the meter OFF Press and Hold the HOLD button and press the amp power button 2 Pand OFF will briefly appear on the display indicating that the auto power off feature is disabled 3 P will not be displayed Note Auto power off is enabled every time the meter is powered on and is automatically disabled when the MX MN feature is enabled Battery Replacement When the En low battery icon appears in the display measurement accuracy may be affected Replace the 6 AAA batteries by removing the rear screw and battery compartment cover Cleaning Periodically wipe the case with a damp cloth and mild detergent Do not use abrasives or solvents Wipe dry as necessary Replace 4 EA11A V1 0 02 07 Specifications General Specifications Display Measurement Range Resolution Data Memory Input Protection Display Update Rate Over range indication Open input indication Auto Power OFF Low battery indication Power supply Battery life Operating Temperature Operating Humidity Storage Temperature Storage Humidity Altitude Approvals Dimensions Weight Accuracy Specifications Multi function LCD 58 to 1999 F 50 to 1300 C 0 1 C F 200 1 C F gt 200 150 sets 20V maximum 2 5 times per second OL appears on the LCD uu appears on the LCD 30 minutes if no key is pressed BT appears on the LCD 6 AAA Batteries
7. to normal operation the H icon will disappear Offset 1 Press the 7 Offset relative button to zero the displayed reading and to use that reading as a reference for all future readings 2 The OFFSET icon will appear in the display 3 The stored reference value will appear in the lower secondary LCD display 4 To exit the Offset function Press and Hold the button until the display returns to standard operation 3 EA11A V1 0 02 07 Memory The meter memory allows for the storage and recall of up to 150 temperature measurements 1 Press the MEM button to store the reading into memory MEM will briefly appear on the display and the memory location will be indicated on the display 2 Press the READ button to recall the data from the indicated memory location a READ and the stored value will appear in the display b Press the A V buttons to step through the memory locations C To exit the READ function Press the READ button 3 To clear data in memory a Turn the meter OFF b Press and Hold the MEM button and press the power button c Release the MEM button and ALL CLr and NO will appear in the display d Press the V button to select YES delete data in memory or NO escape without deleting e Press the MEM button to implement the choice and exit the function Auto Power Off To conserve battery life the meter will go into the sleep mode if no button is pressed for 30 minutes P is displayed