Home
Installation manual OVERVIEW CD 67-DL
Contents
1. 981mm 3 Mechanical setup PA05 Use jig JP01 to place the brackets 45mm PA06L PA06R When assembling PA06 notice that there is a right and a left assembly Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 ___1___1___1___ 3 4 3 Mechanical setup 3 3 Assembling the structure ASMO1 Opes this A connection first PAO4 When assembling PAO5 left and right start with PA04 to make the first cross connection When this connection has been made it s easier to assemble the r840380 profiles ASM02 829782 3 back 829780 5 back 829777 8 back z Se 8 oe a Sd RK NESE 1829778 82 front gt o o INE gt 829779 5 front dd 3 tront 829781 3 front Po 9829762 straight Ag When step 01 is finished and the first unit of the wall is positioned in place then start mounting the first connection brackets The bracket is aligned to the corner bracket The type of bracket is defined by the curvature definition of the wall see figure above Connection brackets for 0 3 5 and 8 are standard other angles are possible when customized Notice that you then level the structure
2. Q Make sure to use nippled hammer bolts to fix the connection brackets the connectionbrackets are aligned with the cornerbrackets Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 gt ___ _ 3 5 3 Mechanical setup ASMO3 After leveling the first column connect the next step 02 structure by means of the respective connection brackets Level this column and repeat this step for the remaining number of columns ASM04 When all columns are placed according to the wall footprint you can start assembling the rows by mounting PA06 and PA04 onto PAO9 Don t forget to place the connection brackets Notice that in case of a curved structure the front connection bracket is placed with JP03 y 1037 y M o EI Curved front connection MLI bracket is placed with JP03 Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _______L_ 3 6 l 1278mm l 1278mm 3 Mechanical setup ASM05 After placing PAO4 you can start assembling all x profiles 1278 mm 1840380 ASMO06 When all columns are placed according to the wall footprint you can start assembling the rows by mounting PA06 and PA04 onto PAO9 Don t forget to place the connection br
3. The switch is slope sensitive and reacts when changing from one position to the other To prevent operation errors a minimum time is required for pushing After sending a command after pushing the switch the next command can only be sent after the release of the switch for at lease 0 5s In case the power switch A is off there is no reaction Projector status Power LED Action Function Standby red static Up Lamp Top becomes active no error lift is going down Down Lamp bottom becomes active lift is going up Standby red static Up Toggling between the status level modes no error for servicing only Standby switch pushed down Down Togaling between the status level modes for servicing only Standby red Up no function error blinking fast J Down no function On green static Up Lamp Top becomes active no error lift is going down Down Lamp bottom becomes active lift is going up On green static Up Toggling between the status level modes no error for servicing only Standby switch y Down Togaling between the status level modes pushed up e for servicing only On green Up no function error blinking slowl J Y down no function Projector is blinking yellow Up no function starting up or shutting down Down no function Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 ___ 7 3 7 4 Indication of Power LED Color Blink Mode Red Static Gre
4. e Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short cut parts that could result in a risk of fire or electrical shock e Never spill liquid of any kind on the product Should any liquid or solid object fall into the cabinet unplug the set and have it checked by qualified service personnel before resuming operations Adjust only those controls that are covered by the operating instructions since improper adjustment of the other controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal operation Lightning For extra protection for this video product during a lightning storm or when it is left unattended and unused for a long period of time unplug it from the wall outlet This will prevent damage to the unit due to lightning and AC power line surges 1 2 6 Servicing Never open the case of a device without first disconnecting the power supply cord Measurements and tests with an opened device may be carried out only in the factory or by specially trained personnel due to the dangers of electrical shock Do not attempt to service this device yourself as opening of removing covers may expose you to dangerous voltage potential and risk of electric shock Refer all service to a qualified BARCO service center Always have service performed on this product by authorized BARCO service personnel Always in
5. Figure 6 9 Service Menu Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 200 gt _ 6 6 6 Final Adjustment and Configuration 6 6 1 Projector Address Projectors leaving production are all set to a projector address 255 When installed in a Display Wall every projector has to get a unique address via it can be controlled This address can be set between 0 and 9 IR Remote Control or between 0 and 255 RS232 Remote Control CAST as well as the RS232 command interface and the IR Remote Control Unit will talk to a specific projector by means of this address By means of the common RC5 address the IR Remote Control can talk simultaneously to all projectors of a Display Wall O The common RC5 address can be set either to 0 or to 1 Please note that CAST Color Adjustment Service Tools requires that the projector O addresses are assigned as indicated in the picture below It is highly recommended to follow this instruction in case for the future use of CAST n Barco Karlsruhe test Barco CAST D fal at File Wall Lamp Tools Help Figure 6 10 projector addresses as required by CAST Display Wall seen from front A top row To modify the projector address e Move the cursor to Projector Address e Press Enter to select Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ 6 7 6 Final Adju
6. Therefore remove again the hoses from the illumination unit and the projection unit and start the fan Run the system in standby Do not switch on the lamps The fans should run for about 5 minutes before continuing Then re attach the hoses Now you can start with the adjustment procedure 4 2 Inserting the Lamp Modules OPO2 Fetch the lamp module on its housing The power socket is on the right side OP03 Insert the lamp carefully Take care that the tubes slide on the guide rods 2 OP04 Mind the position of the fingers the force is to apply on the outer part of the module Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 422 4 Taking into operation OPO5 Press the lamp module tightly into its socket Apply the securing ring on the lamp and press it in axial direction while turning OP06 Turn the securing ring until its hooks click round the guide rods Close the lamp door Use the screw driver and lock the lamp door by turning the screw a quarter turn clockwise The Serial Number of the lamps have to be entered cf Reset Runtime In addition Lamp Optimization has to be performed once for both lamps cf Lamp Optimization It is recommended to do these step as soon as possible Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 4 23 4 Taking into operation 4 3 Selecting the corre
7. Turn the lock ring counterclockwise until it does not move any more don t tighten this ring too strong Tighten carefully the four securing screws of the lenses Check if the position of the picture did not change while locking the DLP engine Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ 52 5 Geometric adjustment 5 2 The projection lens for SXGA systems Figure 5 1 projection lens for SXGA systems 1 Scale for screen size adaptation 2 Focus adjustment 3 Zoom adjustment 4 2 fixation screws for focus lock the focus ring still shows some clearance after locking This due to the mechanical design of the lens Anyway the focus is fixed 5 2 fixation screws for zoom lock 6 Fixation screws for screen size adaptation lock filled with paint screws 6 have to be loosened use a hexagon key size 1 5mm to remove the paint from the screws loosen the screws and turn the lens until its adjusted to 80 84 SXGA red Q As default the lens is adjusted for 50 SXGA systems In case of an 80 SXGA system the scale see picture below Then tighten the screws again SXGA EZA re SXGA Barco Overview cD 67 DL R5976624 installation manual Revision 04 May 200 xm 5 3 5 Geometric adjustment 5 3 The projection lens for XGA systems Figure 5 2 projection lens for XGA systems 1 Scale for screen size adaptation turn
8. 10 seconds After this time the IR will be available again O Press the On Reset button for about 10 seconds to enable the IR remote control again Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 637 6 Final Adjustment and Configuration 6 6 13 Lamps Projector address 15 232 baudrate Internal Patterns Color Brightness Orientation Maintenance Save g Disable IR Version Clear Lamp History P Write Lamp Runtime Read Lamp Voltage More j Runtime warning Lamp Top Serial Number Lamp Bottom Serial Number Figure 6 55 Service Menu Lamps 6 6 13 1 Clear Lamp History Clear Lamp History will erase all former data of all lamps ever used with the system Be carefully when selecting this command Are vou sure You may losefalter unsaved data igure 6 56 confirmation dialog Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 200 _________ _ 6 38 6 Final Adjustment and Configuration 6 6 13 2 Write Lamp Runtime This command opens a sub menu where the runtimes of lamp top and lamp bottom can be changed This function is intended to be used together with the function Lamp Top Serial Number and Lamp Bottom Serial number These two commands together allow exchanging lamps within a Display Wall and keep tracking of their runtimes Write Lamp Runtime Lamp
9. Adjustment and Configuration 6 6 11 Freeze BARG OverView D Operation Lamps Status Brightness Service Projector address RS 232 baudrate Internal Patterns Color Brightness Orientation Maintenance d d d d d d Save Disable IF Lamps Version more Figure 6 53 Service menu Freeze This new function allows to freeze the current picture The picture will be stored in the formatter board at the end of the data treatement chain Thus dithering properties which are introduced earlier in the processing chain cannot be observed dynamically Also the dithering noise is frozen in that case Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 200 gt _ _ 6 36 6 Final Adjustment and Configuration 6 6 12 Disable IR OverView D Operation Lamps Status Brightness Service Projector address RS 232 baudrate Internal Patterns Color Brightness Orientation Maintenance Save m y Disable IR Lamps d Version More Figure 6 54 Service menu Disable IR By selecting this command all OSD content will disappear and the IR will be disabled This function is intended to be used to close a service maintenance session It goes without saying that it is impossible to re enable IR control by using the IR remote control unit IR can be enabled using the RS232 remote control or by pressing the On Reset button on the rear side for about
10. Gdl 2 SLDO4 For all curved setups a small sheet metal strip is foreseen for the front this part is mounted by means of double sided tape Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 I2 5 Geometric adjustment 5 16 Installing the standard and design trim TRMO1 4 R828775 R829704 R828768 The trim consists out of two entities the standard trim which is merely functional and the design trim which has an esthetical function Start with snapping the plastic fixation parts ID fix R822012 onto the profiles These parts do not only fit on the profiles but also on themselves Click 4 ID fix in the horizontal direction and 3 in vertical direction on both sides of the structure for each screen The distance between the plastic parts has to be equally distributed On the horizontal top side the positions will be defined by the stitch plate support Collect all necessary parts of the trim Besides the trim profiles brackets straight and angled ones are included in the delivery of the standard trim To attach the standard trim proceed as follows Assemble the corner brackets with the screws integrated in the profile Connect all vertical profiles for the left and right side and all the horizontal profiles for the bottom and top side b
11. Manual User Interface The Standby Switch B has 3 positions neutral not pushed up pushed to the top down pushed to the bottom The switch is slope sensitive and reacts when changing from one position to the other To prevent operation errors a minimum time is required for pushing After sending a command after pushing the switch the next command can only be sent after the release of the switch for at lease 0 5s In case the power switch A is off there is no reaction Projector status Power LED Action Push time Standby red static Up no error ee Standby red Up 3sec error blinking fast ae On green static Up no error Down 3sec On green Up 6sec error blinking slowly fae oe Projector is blinking yellow Up starting up or shutting down BaN Function switching on the projector only in combination with active lamp selection switch 3 for servicing only reset of error after servicing no function only in combination with active lamp selection switch 3 switching off the projector standby reset of non critical error switching off the projector standby reset of non critical error no function no function Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 IZ 7 Manual User Interface 7 3 Active Lamp Selection Switch The Active Lamp Selection Switch C has 3 positions neutral not pushed up pushed to the top down pushed to the bottom
12. Porgram Input Board Use this command to program the input board This procedure is recommended e g when replacing the Pico2 board Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 200 _ _ 6 29 6 Final Adjustment and Configuration 6 6 6 4 Restart Projector Selecting this command does a switch off cool down switch on sequence BARG OverView D Operation Lamps Status Brightness Service Projector address RS 232 baudrate Internal Patterns Color Brightness Orientation Maintenance d Color wheel Alignment Save Restore Default Settings Leza Program Input Board Disable IR Restart Projector Lamps Lamp Driver Version Ho Source Counter Ta Diagnostics More Dimmer Sensor Power Figure 6 41 Service Maintenance Restart Projector Selecting this comand requires confirmation due to the risk of data loss re you sure You may losefalter unsaved data Figure 6 42 warning about the loss of the user settings Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 200 _ _ 6 30 6 Final Adjustment and Configuration 6 6 6 5 Lamp Driver Selecting this entry displays a list with the lamp drivers of the different versions of the illumination unit Projector address 45 232 baudrate Internal Patterns Color Brightness Orientation l Color Wh
13. a white arrow Three suspension points indicate that the menu item hides a dialog box or a text box A dot indicates which option is selected Grayed out menus or items are not available in this software version 6 4 1 Navigating Use the cursor keys on the RCU to navigate within a menu or a submenu Press Enter to select a menu item Press Enter to open the submenu Press Exit to exit a submenu or menu 6 5 Activating the Menu Bar Press the ADJ key on the RCU to display the menu bar BARG OverView D Operation Mila e ESS Figure 6 2 menu bar Use the cursor key on the RCU to select a menu Press Enter to activate it 6 5 1 Reset Runtime After insertion of a new the lamp its serial number has to be entered The command Reset runtime displays the dialog to enter the serial number BARCO OverView D Operation Lamps Status Brightness Active Lamp Mode Lamp Optimization History Runtimes Reset Runtime d Lamp Top Lamp Bottom Figure 6 3 Reset runtime Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 xm 6 3 6 Final Adjustment and Configuration To enter the serial number of the new lamp proceed as follows e Use the cursor key to highlight Reset runtime e Press Enter to select The following dialog is displayed Reset lamp runtime Enter serial number of new lamp Lamp 1 1111 1 Accept Cancel Figure 6 4 dialo
14. and temporarily lock all horizontal stitch plates SCRO3 Stitching of the screen requires special trained personnel In case of a two row configuration use a Scaffold or a height worker Lenticular the darkest screen the somehow shiny smooth side is the public side The pearly sandblasted looking black side is the projector side Fresnel screen with circular grooves like for all double screen sandwiches the smooth side is towards the projector and the grooved fresnel side is towards the lenticular and thus towards the public side Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 __ 3 9 3 Mechanical setup SCRO4 R814350 Notice that only the black plastic horizontal stitch borders are constant in each wall configuration the vertical stitch borders are defined by the configuration as demonstrated in the figure above Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 __________ 3 10 3 5 Installing the mirrors CY mina the orientation of R840379 Y aa n J Duse protective gloves when installing the mirrors 3 Mechanical setup MIRO1 Place R840379 in between the Ka Ku brackets mind the orientation as shown in the picture U
15. be taken to avoid any damage during the mounting of the final trim The purchaser bears the responsibility for any damage or degeneration during this operation Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ _ 1 2 Pre Installation requirements The air pressure within the control room has to be the same on the both sides of the wall Important remark the total height of a wall is limited and specified per product The height Y directions mentioned in the tables below are based on environmental conditions only In some cases the max height will be limited by the product specification and not by the environmental condition same can happen for the width Maximum number of stitch screens in wall configuration in function of temperature and humidity range X or Y direction 2 3 Floor requirements Sufficient floor space and maintenance area must be available when installing a display wall see applicable drawing and Access The floor must have sufficient load carrying capability to withstand weight distribution for all feet see technical specifications mechanical construction It must not sag by more than 1 mm under the load of the display wall No installation venting ducts sockets etc must be present in the floor in the area of the feet Advice An area of at least 150mm must be kept free around each foot The total construction has to be fixed to
16. dea ONN 6 2 A E A A aetna A Oe 6 3 64 IMC MUNG OU odo eee 6 3 AMIN AVG LING ie Sees echeactoss teats antes T E EO 6 3 6 5 Activating the Menu Baf id 6 3 604 RESET UMUC a n 6 3 625 2 jo OPUN ZIO M AA E Mer A 6 4 636 ACCESS O ME SEVICE Me Usina 6 6 66 11 Pretor Address aa 6 7 ARA O 6 9 6 6 ENa ba lea Le OPD OPEN O A S 6 10 GGA Color BAONE S S ela islas 6 12 Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 __ vii SM RESOA ENEE IE 0 O 6 26 HA COT A tanh See E EEEE E E oawudano san iatexesauad sa sat E ase nesoneee 6 27 GO IN Or 5 OC CONTO loa ri ico o te Mette oe tres ah tas one tod on oes outta erate 6 32 6 6 3 12 DION ES dia 6 33 6 6 9 Dimmer Sensor PO WET ad a o da td do id a S 6 34 A O EN 6 35 a o P E S KE A II A A ET 6 36 A EATE EE 6 37 60 135 LaMDS Ai 6 38 O IN IN 6 42 SA A O O A RAN 6 43 7 Manali ate e ra 7 1 A A A A A A yo 7 1 A O O E O ee te eee a ees 7 2 7 3 Active Lamp Selection WM ita 7 3 7A madcanonmo Power ED ces 2k ocak ye cet hie got aia ee ant hel ae ght yA eat ae Dal Nl el oe Ne etd 7 4 ZS ANGICAtION OL an OOK MED cases sates arias 7 4 7 6 ei A acm ese 7 5 RAS 8 1 e iat ae NEETA 8 1 Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ viii 1 Introduction 1 Introduction This chapter explains the used typographic styles and symbols Safety information is pro
17. e Increase p or decrease 4 the value by means of the arrow keys The menus vanish by pressing Exit on the IR Remote Control unit or if there is no change O within 5 seconds Please note O These settings are only valid for the optical dimmer being disabled In case the optical dimmer is enabled again these settings are set back to their neutral positions 50 6 6 4 6 DIS Calibration Factor The DIS Calibration Factor is determined by CAST O Only experienced user equiped with a lux meter should change the value All DIS values that are displayed and used in the projector are composed by the raw data of the DIS multiplied by a calibration factor DIS value DIS Calibratin Factor 1 correction factor DIS raw data This calibration factor can be set by means of the menu Service Color Brightness DIS calibration factor To change the calibration factor e Use the cursor key to highlight DIS Calibration Factor e Press Enter to select The current DIS Calibration Factor is displayed DIS Calibration Factor Top 1000 Figure 6 33 DIS calibration factor The DIS Calibration Factor can only be changed for the active lamp O The DIS Calibration Factor can be changed between 1 000 and 9 999 The DIS Calibration Factor is set for both lamps individually Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ _ 6 24 6 Final Adjustment and Configu
18. for this projector has no function for this projector To enter the remote control address have no function for this projector Except for brightness and contrast these keys have no function for this projector The controls of brightness and contrast are only enabled in case the optical dimmer is disabled cf Error Reference source not found has no function for this projector has no function for this projector has no function for this projector to start up the adjustment mode or to confirm an adjustment or selection in the adjustment mode to make menu selections when in the adjustment mode RCU cursor key up cursor key down cursor key right cursor key left Use the cursor keys up or right for increasing a value Use the cursor keys down or left for decreasing a value to leave the adjustment mode or to scroll upwards when in the adjustment mode lights up when a button on the remote control is pressed This is a visual indicator to check the operation of the remote control Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 H_______ 6 2 6 Final Adjustment and Configuration 6 3 General OverView D has a build in PC like toolbar menu which allows easy access to different parameters for setting up the projector The toolbar menu is activated by pressing ADJ Menu items which are not applicable are grayed out 6 4 Menu Layout The existence of a submenu is indicated by
19. hrs of Lamp Runtime Figure 6 60 Lamp Runtime Warning set to 6000 hours After the specified runtime time a warning message will appear on the screen Lamp Top 6001 hrs Lamp Bottom 4711 hrs Figure 6 61 Lamp Runtime Warning Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 ______LLLY 6 40 6 Final Adjustment and Configuration To change the specified runtime e Move the cursor key to the respective field e Enter the new value by means of the numeric keys of the IR Remote Control in Hot Standby mode the warning pops up if the operation time of one of the lamps O exceed the specified value In Cold Standby mode the warning pops up if the operation time of the active lamp exceeds the specified value 6 6 13 5 Lamp Top Serial Number Lamp Bottom Serial Number This menu allows to change the serial number of the currently used lamp and should be used in conjunction with the menu Write Lamp Runtime as mentioned above Enter Serial Number ma Accept Cancel Figure 6 62 Enter serial number after lamp exhange Use these commands when exchanging lamps within a Display Wall Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ _ 6 4 6 Final Adjustment and Configuration 6 6 14 Version BARCO OverView D Operation Lamps Status Brightness Service Projec tor address RS 232 baudrate Intern
20. of white is required The color wheel incorporated in the DLP projection engine has 4 sectors red R green G white W and blue B White is generated by the primary colors via the addition of full red full green and full blue W1 R G B White is also generated by the white segment W2 W White is also generated by the so called spoke light recapture If the DMD is left ON while the color segments change there are additional contributions of adjacent segments R G G W W B B R Spoke light recapture gt Time Spoke Light Recapture SLR R G G W W B B R 2 R G B 2 W W3 In case the white segment and spoke light recapture are activated the white output is boosted The White Peaking Factor is defined as the relation of all whites to the RGB White Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 H_ __1___ 6 15 6 Final Adjustment and Configuration WI W2 W3 RGB W SLR WI RGB It s obvious that the minimum of the White Peaking Factor equals 1 no white segment no spoke light recapture White Peaking Factor The maximum of the White Peaking Factor all three contributions is about 1 8 It varies slightly with different lamps The White Peaking Factor can be linear scaled between its minimum and its maximum by O means of thw White Peaking Value The White Peaking Value can be set by means of the command Service Color Brightness W
21. projection modules with the graphical card of the controller please keep in mind that optical cables shall not be bent too much When using optical fibre data cables please note that they may not be bent to a curvature with a bend radius less than 11cm 6 2 The IR Remote Control Unit Figure 6 1 IR Remote Control Unit RCU Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ 6 1 6 Final Adjustment and Configuration 6 2 1 Terminology of RCU controls 10 11 12 13 14 15 16 17 18 Function keys ADJ Address key Selection key PAUSE Standby Mute Help Digit buttons Audio controls Picture controls PHASE Freeze TEXT ENTER Cursor Keys EXIT RC operating indication have no function for this projector ADJUST key to enter or exit the adjustment mode recessed key to enter the address of the projector between 0 and 9 Press the recessed address key with a pencil followed by pressing one digit button between 0 and 9 has no function for this projector has no function for this projector stand by button to start projector when the power switch is switched on and to switch off the projector without switching off the power switch has no function
22. the floor Typical M10 plugs will be mounted in holes in the floor If raised floor false floor is used it s advised to put the construction on the concrete floor underneath To increase the stability additional fixation is advised to the ceiling and or to the wall This additional fixation is not delivered by standard The customer is responsible for drilling holes into the concrete floor or concrete columns For installations on wheels the floor must have a certain level of flatness Carpet or wasting floor is not permissible The max difference in height must be less than 3mm across the complete floor space of the wall including the movement area 2 4 Luminance Light falling directly on the screen will negatively influence the resulting contrast level The design of the lighting should avoid as much as possible light falling directly on to the screen The real performance of the projectors will be determined by the light condition on the screen A good contrast ratio is guaranteed with light input directly on the screen not more than 50 lux There are no constraints on the luminance on e g the operator positions Light behind the wall is required for installation and service During normal operations all lights behind the wall must be switched off All daylight must be avoided as well Bright colors for the ceiling the walls and floor surrounding the screen have to be avoided Do not use reflecting materials for the ceiling th
23. wall mind the following recommendations Leave a gap of 100mm around the screen Make sure to take the distance from the lower screen edge to the floor into account standard 1287 5mm Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 ____ 2 6 3 Mechanical setup 3 1 Tools needed for installation 1 set of screwdrivers 1 tape measure 10m 1 tape measure 2m 1 water level cord 50m 1 pencil 1 stanley knife 40 Wy OOQ 0000 All connections between plain metal e g corner brackets and the profiles have to be made with nippled hammer bolts long hammer bolts All connections between coated metal e g shielding and the profiles have to be made with nippled hammer bolts and spring washers see below 3 Mechanical setup 3 2 Preassemblies 840380 l 1278mm 1840378 l 1268mm 1840379 1268mm When connecting the profiles make sure to use nippled hammer bolts long hammer bolts 25mm PAO1 1200mm Use profile r810237 feet profile to make the preassembly 01 the length can be different in case of a customized feet height First place the two brackets with JP01 and JP02 end with the third bracket which is aligned to the top of the profile Notice that according to the drawing the inside thread is pointing downwards Use jig JPO1 45mm and jig JPO2 456 7 mm to place th
24. 0 6 0 5 0 4 0 3 0 2 0 1 normalized DIS value 1400 1600 1800 2000 2200 2400 2600 2800 3000 dimmer position steps Figure 6 29 intensity of emitted light depends on the position of the dimmer wheel Only dimmer positions between approx 1600 minimum brightness and approx 2600 maximum brightness can be addressed The dimmer wheel can be enabled or disabled by means of the menu Service Color Brightnes Optical Dimmer If Optical Dimmer is selected a dialog box pops up where the current status is indicated and where this status can be changed Optical Dimmer Y Disabled Enabled Figure 6 30 Dialog Box to enable disable the optical dimmer The correct setting is Enabled Disabled should only be selected in case the dimmer is defective stuck Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ _ 6 22 6 Final Adjustment and Configuration Optical Dimmer enabled This is the default setting which allows automated brightness control and the lumens lock mode At reboot the home position of the dimmer is searched Since in this operation mode brightness is automatically controlled the electronic control of brightness and contrast of the IR Remote Control unit is not available No manual interference in the automated operation mode Optical Dimmer disabled The correct setting is Enabl
25. 10 Horizontal trapezoid A horizontal distortion looks like this or similar Figure 5 13 Rear view horizontal trapezoid Turn the adjustment screw H1 counterclockwise Figure 5 5 and H2 clockwise until the vertical lines gets parallel to the border of the screen Figure 5 14 Rear view horizontal trapezoid Turn the adjustment screw H1 clockwise Figure 5 5 and H2 counterclockwise until the vertical lines gets parallel to the border of the screen Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ 5 10 5 Geometric adjustment 5 11 Rotation The distortion rotation looks like this or similar Figure 5 15 Rear view rotation Turn the rotation adjustment screw Figure 5 6 F clockwise until the horizontal lines gets parallel to the border of the screen Figure 5 16 Rear view rotation Turn the rotation adjustment screw Figure 5 6 F counterclockwise until the horizontal lines gets parallel to the border of the screen Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 ____ _ 5 11 5 Geometric adjustment 5 12 Horizontal picture shift The horizontal picture shift may looks like this or similar Figure 5 17 Rear view horizontal position Use the adjustment screws for horizontal lens shift Figure 5 5 C Tighten the left and loosen the right screw to move the picture to the rig
26. Bottom Figure 6 57 Service Lamps Write Lamp Runtime 6 6 13 3 Read Lamp Voltage This new function allows the estimation of the burner voltage Pressing this button will open a sub menu which shows the voltage value after a few seconds measurement time This measurement is based on some optical properties which are measured and used for voltage determination Make sure to select the correct lamp driver Otherwise the displayed values are invalid Read Lamp Yoltage value Figure 6 58 Service Lamps Read Lamp Voltage Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 200 _ 6 39 6 Final Adjustment and Configuration 6 6 13 4 Runtime Warning BARCO OverView D Operation Lamps Status Brightness Projector addr RS 232 baudrate Internal Patterns Color Brightness Orientation Maintenance Save Freeze Disable IR Clear Lamp History Version write Lamp Runtime More Read Lamp Voltage Runtime warning Lamp Top Serial Number Lamp Bottom Serial Number Figure 6 59 Service Lamps Runtime Warning In this menu the limit for a Lamp Runtime Warning can be set in the range 0 hours to 15000 hours Default value is 6000 hours nominal operation time of the 120W UHP lamps e Move the cursor key to Runtime Warning e Press Enter to select A dialog pops up where the current lamp runtime is indicated Lamp Runtime Warning After hy
27. CO being a component of the system or independent services will be deemed invalid provided the damage is not proven to be attributed to the absence of properties guaranteed in writing or due to the intent or gross negligence on the part of BARCO If the purchaser or a third party carries out modifications or repairs on good delivered by BARCO or if the goods are handled incorrectly in particular if the systems are commissioned or operated incorrectly or if after the transfer of risks the goods are subject to influences not agreed upon in the contract all guarantee claims of the purchaser will be rendered invalid Not included in the guarantee coverage are system failures which are attributed to programs or special electronic circuitry provided by the purchaser e g interfaces Normal wear as well as normal maintenance are not subject to the guarantee provided by BARCO either The environmental conditions as well as the servicing and maintenance regulations specified in this manual must be complied with by the customer Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 ___ _ Y Revision sheet To e BARCO Control Rooms GmbH An der Rossweid 5 D 76229 Karlsruhe Phone 49 721 6201 0 Fax 49 721 6201 298 E mail docu de bcd barco com Web www barcocontrolrooms com From Date Please correct the following points in this documentation R5976624 page wrong corr
28. Installation manual OVERVIEW CD 67 DL R59 6624 R5976624 Current Version Title OVERVIEW CDG67 DL Installation Manual ID no R5976624 Revision 04 Date May 2006 main issue update chapter 1 chapter 2 chapter 3 chapter 4 Proper grounding cable fixation to profile chapter 5 chapter 6 chapter 7 chapter 8 chapter 9 new The corresponding chapters are new or completely revised COTT Passages of the corresponding chapter were corrected see modification bars add Passages of the corresponding chapter were added see modification bars Document History Modifications which result in a new version are indicated by a vertical bar Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 ii Trademarks Brand and product names mentioned in this manual might be trademarks registered trademarks or copyrights of their respective holders All brand and product names mentioned in this manual serve as comments or examples and are not to be understood as advertising for the products or their manufacturers Copyright 2004 by BARCO Die Weitergabe sowie die Vervielf ltigung aller Unterlagen die von uns berlassen werden deren Verwertung und Mitteilung ihres Inhaltes an Dritte ist nicht gestattet soweit dies nicht ausdr cklich zugestanden ist Urheberrechte insbesondere auch solche an Software werden nur insoweit bertragen als es f r die Erreichung des speziellen Vertragszwecks erforderlic
29. ackets Notice that in case of a curved structure the front connection bracket is placed with JP03 Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 ___1__1___1___1_1 3 7 3 Mechanical setup 3 4 Stitching the screens SCRO1 R840065 R840066 mine the arrow pointing to the floor R814267 The stitch facilities consist of two horizontal and two vertical stitch plates Start with assembling the horizontal stitch plates Hook the horizontal stitch plates R814267 and R814270 into each other and attach them to the structure on top of the horizontal screen frame profiles 1278mm R840380 Mount all vertical stitch plates R840065 on to the structure make sure to align them to the vertical screen profiles with the arrow pointing to the floor Hook vertical stitch plate R840066 in to the slots of R840065 SCRO2 Detailed view stitch borders Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 200 gt 3 8 O stitching the top screens stitch support plate LENTICULAR FRESNEL Di the orientation of the lenticular and fresnel 3 Mechanical setup SCRO3 Center
30. al Patterns Color Brightness Orientation Maintenance Save Freeze Disable IF Lamps Version More Figure 6 63 Service menu Version Select this command to see the release status of different modules of the firmware CPU ilins 00 08 OSD ailir 00 11 OSD Data 00 04 Default Program 00 03 Standard Prograrn 00 51 DIS Program 02 00 Figure 6 64 Service Version Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _______ 6 4 6 Final Adjustment and Configuration 6 6 15 More The More menu gives access to activate the Hot Standby mode which is only accessible with an authorization code OverView D Operation Lamps Status Brightn Service Projector address RS 232 baudrate Internal Patterns Color Brightness Orientation Maintenance Save Freeze Disable IR Lamps Version More Figure 6 65 Service menu More To access the Hot Standby option e Use the cursor key to highlight More e Press Enter to select A dialog box opens to enter the Authorization Code Authorization Code Enter code Figure 6 66 Access requires Authorization Code Contact Bernard Geitz to receive the projector specific Authorization Code email bernhard geitz barco com phone 49 721 6201 110 e Use the numeric keys of the IR Remote Control unit to enter the Authorization Code Barco OverView cD 67 DL R5976624 installation manual Re
31. ashers have been applied use the spring washers included in the grounding kit The following pictures show some of the details to be checked All connections between plain metal e g corner brackets and the profiles have to be made with nippled hammer bolts long hammer bolts see pictures above first row All connections between coated metal e g shielding and the profiles have to be made with nippled hammer bolts and spring washers see pictures above second row If the structure does not comply with these rules there is no proper grounding Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 3 16 3 Mechanical setup GRDO2 principle drawing OverView cD80 has to be fixed to the floor by means of stabilization corners one attached on each vertical profile Usually the stabilization corner is fixed by means of an M10 plug In case of false floor the wall has to be fixed to the concrete floor by means of thread rods nuts and anchors raised floor To increase stability additional fixation is advised to the ceiling and or the wall not provided in the standard delivery Fixation to the ceiling wall concrete floor Every two rows and every two columns have to be connected to the ceiling wall The design of connection and its implementation is part of the project management and customized for each installation Please contact the responsi
32. available gamma values Disable applies a gamma value of 1 For OverView D series do NOT use any of the TI gamma values O gamma 2 7 should be used with utmost care Influence of White Peaking on Gamma For DLP projection engines which use the white segment and spoke light recapture the influence of the gamma value on white and on gray levels is much higher The primary colors and secondary colors are not affected The following table shows the selected gamma value and its effective equivalent gamma value White Peaking value 0 effective gamma value White Peaking value 10 1 0 1 6 2 0 32 272 3 4 23 3 6 Del 4 0 Due to the White Peaking for white and gray R G B even a gamma value of 1 disabled results in a non linear effective gamma curve and thus in a non linear response Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _______1_ 6 17 6 Final Adjustment and Configuration It is recommended to set the White Peaking value first and then adjust the gamma O accordingly A subsequent change of the White Peaking value will influence the gamma response The following diagrams show the gamma curves for the gamma values 1 and 2 3 for an operation without white segment and without spoke light recapture White Peaking 0 and for an operation with full white segment and full spoke light recapture White Peaking 1 These diagrams clearly show the influence of
33. ble project manager Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ 3 17 3 Mechanical setup 3 7 Installing the engine ENGO1 Start mounting the projection unit PU Place the support bracket onto the position points of the 30 60 profile Then fix the PU on the profile with three B361320 DIN912 M6x35 ENGO2 Continue installing the illumination unit IU Make sure that two M6x7 are mounted loosely onto the 30 30 profile Place the IU over the two screws and the two position points on the 30 60 profile Then shift the IU towards the PU position point and tighten all screws In this stage you have to lock the position of the 30 30 profile a A ue sure the PU IU 6 foam connection is OK Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _______ _ 3 18 3 Mechanical setup ENGO3 The lower side of the fan module is sided into the first slot of the 30 30 profile and fixed to the engine profile by M6x7 Pay attention not too tighten the screws since you need to install the engine shielding to know the right position of the fan ENGO4 Place the engine shielding in order to position the fan module align the engine shielding with the illumination unit Proceed with aligning the fan module with the engine shielding and tighten the sc
34. cassette and will be programmed in production Do not change alter this value In case of color wheel exchange a new delay value has to be entered by the support O engineer This specific delay value will be shipped together with the spare color wheel To enter a new delay value proceed as follows e On the service menu entries move the cursor to Color Wheel Alignment e Press Enter to select A dialog box pops up to enter the new value Index Delay M44 AS Figure 6 37 Index Delay Arrows pointing to the left decrease a value arrows pointing to the right increase a value Clicking on a single arrow increases decreases 4 the value per 1 Clicking on the double arrows increases p decreases 4 4 the values per 10 Clicking on the right most left most arrow sets the value to the maximum or minimum 0 Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 627 6 Final Adjustment and Configuration 6 6 6 2 Restore Default Settings OverView D Operation Lamps Status Brightness Service Projector address RS 232 baudrate Internal Patterns d Color Brightness Orientation d Color Wheel Alignment Peza Program Input Board Disable IF Restart Projector Lamps Lamp Driver version Mo Source Counter Ta Diagnostics More a Dimmer Sensor Power By means of this command the settings stored in pro
35. ct lamp driver There are three kind of lamp drivers for the illumination unit of OverView D it is mandatory that you check if the default lamp driver Compact is the correct one for your system Select Service Maintenance Lamp driver A list with the lamp drivers of the different versions of the illumination unit is displayed OverView D Operation Lamps Status Brightness Service Projector address RS 232 baudrate Internal Patterns Color Brightness Orientation Maintenance a Color Wheel Alignment Save t Restore Default Settings ls us Program Input Board Disable IF Restart Projector Larnps Lamp Driver Version Mo Source Counter 22 Diagnostics More Dimmer Sensor Power Lamp Driver Compact PowerPack 100 PowerPack 120W Y Osram 200 The following table lists the article number of the illumination unit and the required lamp driver R764226 Compact R764581 Powerpack 100W R764582 Powerpack 120W For 80 the illumination unit with 200W Osram Lamp driver ist NOT an option Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ 4 24 5 Geometric adjustment O SXGA and XGA use different lenses 5 1 Adjustment Overview FOCUS PICTURE SIZE LOCK RING LENS a SECURING ADJO1 After setting up the system optical adjustment must be done I
36. ctuations have to be limited up to 5dgc per hr The projector units operate between 10 and 40 dgc The thermal dissipation of the projector units has to be taken in consideration The projector units have built in temperature detection and will switch off automatically when the temperature limits are exceeded The graphical generator equipment operates between 10 and 40 dgc In case these products are mounted in a rack the max room ambient temperature has to be limited to max 25 dgc or additional forced cooling has to be foreseen in the rack The materials and products can be stored between 30 and 65 dgc and humidity below 95 RH non condensing Screens have to be stored below 40dac 24hrs prior to installation the screens have to acclimatize to the control room conditions They can stay in their protective packaging during this acclimatize period The temperature and humidity conditions in the control room must be within specification during installation and maintained afterwards The room has to be dust free during the installation and maintained afterwards The control room must have an acceptable dust class of 100000 or better 100000 particles of 0 5um or larger per cubic feet comparable with clean desk room All construction reconstruction decoration activities must be completed before the installation of the system However the trim around an integrated wall can only be mounted after completion of the wall All precaution should
37. d be retained for future reference e All warnings on the device and in the documentation manuals should be adhered to e All instructions for operating and use of this equipment must be followed precisely 1 2 3 Installation Installation and preliminary adjustments should be performed by qualified BARCO personnel or authorized BARCO service dealers 1 2 3 1 Power Connection This product should be operated from an AC power source Power input is auto ranging from 100V to 240V Check the power rating on your outlet before connecting the devices to the wall outlet or to a power strip Contact your facilities manager or a qualified electrician if you are not sure what type of power is supplied to your building All equipment in the system is equipped with a 3 wire grounding plug a plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the purpose of the grounding type plug The devices are designed to operate with single phase power systems having a grounded neutral conductor To reduce the risk of electrical shock do not plug into any other type of power system Use only the power cord supplied with your device While appearing to be similar other power cords have not been safety tested at the factory and may not be used to power the project
38. duction 1 2 9 Cleaning instructions screens and mirrors Wash with a solution of mild soap or detergent and lukewarm water Use a clean lint free soft cloth applying only light pressure Rinse with clean water and dry by blotting with a damp lint free cloth or chamois Always use a clean new lint free cloth for cleaning the screens s front side Do not clean with the same cloth used for the beaded side The used cloth ma contain bead particles which could scratch the screen s front surface Do not use the following cleaning cleaning agents since these can scratch or detoriate the screen surface Window cleaning sprays kitchen scouring compounds sovlents such as acetone gasoline benzene alcohol carbon tetrachloride or lacquer thinner Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ _ 1 6 2 Pre Installation requirements 2 Pre Installation requirements 2 1 Power and grounding Attention has to be paid to the electrical installation Earth current loops in the installation must be avoided The neutral power conductor of the electrical net and the grounding conductor must be separated All circuits have to use the same ground level also indirectly connected equipment If possible all circuits should come from the same phase Each projector has specific power requirements see technical specification projectors Enough circuits have to be available The
39. duction can be applied again Restoring can be done for the projection unit and for the illumination unit After the Restore command for the respective device all adjustments will be lost To restore the parameters set in production e Move the cursor key to highlight Restore Default Settings e Press Enter to select A selection box shows up to select the device which settings should be restored Restore Default Settings Projection Unit Y Illumination Unit Figure 6 38 select the device to restore its default production settings e Move the cursor key to highlight the desired device e Press Enter to select Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _____LLLL 6 28 6 Final Adjustment and Configuration A warning pops up to inform that the user settings will be lost e Select Yes to restore the production settings select No to abort the procedure Confirmation Are vou sure You may losealter unsaved data Figure 6 39 warning about the loss of the user settings Operation l ass Service 1S 232 baudrate Internal Patterns Color Brightness Orientation Maintenance a color Wheel Alignment Save t Restore Default Settings Seze Program Input Board Disable IR Restart Projector Lamps Lamp Driver Version Mo Source Counter 2 Diagnostics More o Dimmer Sensor Poner Figure 6 40 Servic Maintenance
40. e brackets PAQ2 670mm 535mm Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 3 2 3 Mechanical setup PAO3L PA03R R829761 Notice to make both a left and right preassembly PAO3L and PAO3R Use jig JPO1 to place the brackets 45mm iy PA04 B362667 When attaching the KaKu brackets pay special attention to the orientation of the 60 30 profile r840378 Use B362667 M8x10 to connect r840381 and r840383 to r840378 be sure to tighten the screws mind the orientation of the 30 60 profile Due open sides directed to the back and bottom of the KAKU bracket Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 200 gt _ 3 3 670mm PAO5 1840423
41. e disable the dimmer sensor power Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ _ 6 34 6 Final Adjustment and Configuration 6 6 10 Save BARCO OverView D Operation Lamps Status Brightness Projector address RS 232 baudrate Internal Patterns Color Brightness Orientation Maintenance Save Save nov PP F Freeze AU Save Disable IF Lamps Version More igure 6 51 Service Save This entry opens a sub menu with the items Save now and Auto save Per default every 15 minutes the projector saves all parameters During this process which lasts about 7 seconds the projector is blocked for communication Since this might be annoying in some cases the new functionalities Save now and Auto Save have been introduced Auto Save allows to disable or enable the regularly saving procedure If disabled the projector only stores back a very small subset of the available data a fast procedure which is hardly noticed However changes of parameters like color coordinates will not be stored regularly To store them the Save now command has to be given Auto Save Disabled Enabled igure 6 52 enable diasbale Auto Save When the projector is switched to standby it will store all data No extra Save now command has to be given Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 200 2 6 35 6 Final
42. e projector is in cold standby and the active lamp is changed by the operator e When the projector is in Auto Switch Mode and the projector initiates the change of the active lamp The alternation speed depends on the current projector timing 6 6 7 No Source Counter BARG OverView D Operation Lamps Status Brightness Projector addr 45 232 baudrate Internal Patterns Color Brightness Orientation Maintenance a Color Wheel Alignment Save t Restore Default Settings ERZE Program Input Board Disable IF Restart Projector Larnps Lamp Driver Version Mo Source Counter 2 Diagnostics Dimmer Sensor Power Figure 6 45 Service Maintenance No Source Counter In case of color bar problems the projector suffers from loss of signal although the sources are connected this command can be selected to check how often the signal has been lost A dialog opens which shows the actual value Mo Source Counter times source has Failed igure 6 46 No Source Counter to check how often the signals has been lost Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 __1____ _ 6 32 6 Final Adjustment and Configuration 6 6 8 12C Diagnostics Maintenance d 2 Diagnostics igure 6 47 Service Maintenance I2C Diagnostics This command displays the 12C Diagnositc table of the devices including their addres and their status Consult this table in case an er
43. e walls and floor surrounding the screen Sufficient lighting in the projection room is required during installation Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ _ 2 2 2 Pre Installation requirements 2 5 Access The buildings have to be accessible during extended straight time 6AM 12PM 7 days per week From the delivery point to the installation site the doors and passages require a minimum width of 1500mm and height of 2000mm for an installation In case the projection room is located on the ground floor the room need to be accessible with any trolley In case the projection room is located on a floor level an elevator is required The elevator needs a minimum entrance and cabin size of 1500 x 1800 x 1200mm width x height x depth The support power must be 1000 kg minimum The elevator must be available during the installation period 2 6 Installation and room requirements Behind the wall a minimum distance is required of 750mm For the use of a HOIST 1000mm is required At the left or right side of the wall a passage is required of 750mm For walls with a height more than 2500 mm a scaffold or tower wagon will be required This equipment must be able to reach the top of the wall In case no HOIST is ordered and wall is more than 2500 mm high equipment must be foreseen to load the projectors into the wall This equipment must be able to lift up the project
44. ect Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 Contents VITRO ALUNE E i eat 1 1 Wel SUV NCS ol 1 2 RESIES CHOICE OM E e O II O 1 3 DZS d A ee setae ieee en ental laa ieee 1 3 1 2 2 General satety INSTI CUIONS sarasi a a E A O 1 3 E E AEE E AT AEA AE ETE EN E EE ENTA E EE A EA 1 3 UUs PVC ONIN e a E a E TT 1 4 PO DO AUI ON ean O O A 1 4 A a Stee Renee reg A See eee rer err mee entre nee Denar rane 1 5 T2 UNPACKING OGG VICES sd cartes se lt de el ol ete 1 5 12 8 Modification OF COVICES sa 1 5 1 29 Cleaning Instructions screens ANC MITOS ii Ai 1 6 2 Pre Installation TEQUES MENS a 2 1 2 1 Power and ION dd E 2 1 2 DP ENVirOnmMental COMGIIONS Iosis a 2 1 22 1 General CONGIEIOMS a 2 1 DS FOOL FO CQUIRG MEN Seti cut ok caast caste E E T 2 2 ZALMAN CS st AS SA 2 2 DASS Taro o 2 3 2 6 Installation and room FEQUIFEMENTS cccccscesccescesscesscessesscesscesecesscssecsssesscesscesscesecesecssesssessecesseesesseens 2 3 DT OOUP A A S 23 ZS Overal dimensio as 2 4 2H Mantenan CO aede a a a ac 255 210 Bunt cOn Ural oo 2 6 Mechanical set Dan O Ata 3 1 3 1 Tools needed for installation ooooonnnnnconnocnnonanononanonanonanonnnonnnnonono nono nonnnoonona nono nona non n non non anno nnnn nana nnss 3 1 e N 3 2 30 ASSCIMOINMNG Lie SUC UU xxanesecwsrcsctaccnasecninss cteuinecassudentasals E N 3 5 E tent der nesta lea aateets ta Arnetilas E tee Oi Lec Sa seed te Lc coe 3 8 3 5 Installing
45. ed O Disabled should only be selected in case the dimmer is defective stuck This mode should only be used by advanced support engineers If disabled is selected the dimmer will stay at its current position and even at reboot no search for the home position of the dimmer is performed In this mode the addressing of reference slits on the dimmer wheel will not be available to the lamp optimization algorithm In consequence it will be less powerful A non uniformity in brightness might appear To provide a workaround brightness and contrast can be adjusted by means of the respective buttons on the IR Remote Control unit Brightness adjusts the offset applied to the RGB input data O Contrast changes the gain applied to the RGB input data The Brightness and Contrast dialog boxes show up after pressing the Brightness Contrast button on the IR Remote Control unit Brightness Top A so Figure 6 31 Brightness setting only available if Optical Dimmer is disabled Contrast Top Figure 6 32 Contrast setting only available if Optical Dimmer is disabled Only the settings for the active lamp can be modified The active lamp is indicated in the O caption of the settings dialog The values are stored for both lamps individually Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ 6 23 6 Final Adjustment and Configuration To change the values
46. eel Alignment Save t Restore Default Settings Freeze Program Input Board Disable IF Restart Projector Larnps Lamp Driver Version Mo Source Counter 22 Diagnostics More Dimmer Sensor Power Figure 6 43 Service Maintenance Lamp driver Selecting this command opens a dialog to select the correct lamp driver Default setting factory setting is PowerPack 120W This selection has to be adjusted according the actual lamp driver employed in the system Compact o PowerPac k 100 Y PowerPack 120 Osram 2004 Figure 6 44 select the correct lamp driver Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 __ 6 31 6 Final Adjustment and Configuration The following table lists the article number of the illumination unit and the required lamp driver R764226 Compact R764581 Powerpack 100W R764582 Powerpack 120W Make sure to have the correct settings Otherwise color artifact and wrong control parameters will affect the performance of the projector SXGA projectors ONLY run with Power Pack lamp driver Please keep in mind In case of the Powerpack lamp drivers the following feature is normal and cannot be avoided During ignition of the lamp some color alternation on the screen will show up for about one second This behavior can be observed e When the projector is in cold standby and is switched to hot standby e When th
47. en Static Yellow Blinking Fast Yellow Blinking Slowly Green Blinking Slowly Red Blinking Fast Green Blinking Fast 7 5 Indication of Lamp Door LED Color Blink Mode Red Static Green Static Yellow Static 7 Manual User Interface Meaning Projector is in Standby Mode Off Projector is in Operation Mode 0n Projector is starting up Projector is switching off Projector is in Operation Mode On a Non Critical Error occurred Check status for more information then press Standby Switch On for acknowledge Projector off Standby because of a Critical Error Service required after service press Standby Switch On for acknowledge Projector is in Operation Mode 0n a Critical Error occurred Check status for more information Meaning lamp is switched off lamp door can be opened for servicing lamp is switched on DON T open the lamp door in case the door is opened the lamp is switched off automatically lamp is switched on for Hot Standby mode or Auto Switch mode 17 minutes changeover time DON T open the lamp door in case the door is opened an error occurs O Only open the lamp door in case the lamp door LED shines red Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ _ 7 4 7 6 Indication of the Status LEDs Color Blink Mode Top LED status Red Static LED of Lamp Top Green Static Yellow blinking fast Yellow blink
48. er at 115200 Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 200 H HW ______LLL 6 9 6 Final Adjustment and Configuration 6 6 3 Internal patterns Use Internal Patterns to check some properties of the system OverView D Operation Lamps Status Brightness Service Projector address BS 232 baudrate Internal Patterns Outline Color Brightness Hatch Orientation Color Bars Maintenance Checkerboard Pixel On Off siecle Lens Adjustment Disable IF RGB d d d d Lamps Version More Figure 6 14 Service Menu Internal Patterns e Move the cursor to Internal Patterns e Press enter to select A list of available patterns is displayed e Move the cursor key to select the desired pattern e Press Enter to select The test pattern is applied The following table gives some recommendations what the various test pattern can be used for Pattern use Outline Hatch for geometry adjustment Color bars to check primaries and secondaries Checkerboard to check for straylight Pixel On Off to check electronics and projection lens performance Lens Adjustment to check the projection lens adjustment RGB arbitrary colors explanation see below Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _____LLLLY 6 10 6 Final Adjustment and Configuration 6 6 3 1 The RGB test pattern By means of the RGB test pattern menue any de
49. es additional notes Next to this icon you find further information This arrow marks tips Next to this icon you find important notes Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _______ 1 2 1 Introduction 1 2 Safety Instruction This section describes safety precautions which must be observed when installing and operating a product from BARCO 1 2 1 Standards Safety Regulations The equipment is built in accordance with the requirements of the international safety standard IEC950 UL1950 and CSA 22 2 No 950 which are the safety standards of information technology equipment including electrical business equipment The safety standards of information technology equipment impose important requirements on the use of safety critical components materials and isolation in order to protect the user or operator against the risk of electric shock and energy hazard and having access to live parts Safety standards also impose limits to the internal and external temperature rises radiation levels mechanical Stability and strength enclosure construction and protection against risk of fire Simulated single fault condition testing ensures the safety of the equipment to the use even when the equipment s normal operation fails 1 2 2 General safety instructions e All the safety and operating instructions should be read before using this unit e The operating instruction manual shoul
50. estricted area For better recognition these screws are locked with paint The following picture shows the respective screws in detail Figure 5 4 Never touch these screws Screws Function 1 2 and 3 not visible Scheimpflug adjustment 45 6 Mounting and fixation screws Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 gt 5 5 5 Geometric adjustment 5 5 Adjustment devices Besides the adjustment rings on the projection lens to adjust focus and size there are adjustment screws to correct distortions The following picture gives an overview about the position and the function of the adjustment screws Figure 5 5 top view of lens Figure 5 6 side view lens and adjustment devices A Lens H1 H2 Horizontal tapezoid B Lens securing screws V1 V2 Vertical trapezoid C Horizontal lens shift E Mounting angle D Vertical lens shift F Rotation Table 1 Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _________ _ 5 6 5 Geometric adjustment 5 6 First steps The entire projection unit is locked via the lock ring aee qe Lock ring Figure 5 7 Lock ring e Unlock the system loosen the lock ring e Loosen the screen size adaptation lock screws and the zoom lock screws on the projection lens e Loosen slightly the securing screws of the projection lens B O Without unlocking the system no adjustment is pos
51. evision 04 May 2006 _ _ 6 11 6 Final Adjustment and Configuration 6 6 4 Color Brightness BARCO OverView D Operation Lamps Status Brightness Service Projector address RS 232 baudcrate d Internal Patterns d Color Brightness F Color Coordinate 4djustement Orientation t White Peaking Maintenance d Degamma t SetBrightness BEZE Optical Dimmer Disable IR DIS Calibration Factor Lamps Version More Figure 6 16 Service Menu Color Brightness 6 6 4 1 Color Coordinate Adjustment Color Adjustment has to be done by CAST O Only very experienced personnel in possession of a spectrometer should access this menu In case there is an urgent need to use this menu item make sure that White Peaking is set first Color adjustment is only valid for one White Peaking value This menu provides some essential information for the ASIC the factory colors of the DLP engine and the desired target colors O The color locations for DLP are indicated in coordinates of the x y color space CIE 1931 Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 6 12 6 Final Adjustment and Configuration Figure 6 17 Chromaticity diagram CIE 1931 The ASIC needs to know the uncorrected color coordinates for red green blue and white as well as the relative lumens of each color On the Color Coordinate Adjustment dialog this informa
52. g to enter the serial number of a new lamp e Use the cursor keys to highlight the input field e Use the numeric keys on the RCU to enter the serial number of the new lamp e Click Accept to activate the serial number These steps have to be performed for both lamps Then Lamp Optimization should be done 6 5 2 Lamp Optimization Since the light is coupled into the light rod by means of a mirror the position of the mirror together with the actual lamp properties determine the light yield During the Lamp Optimization procedure the light output of the active lamp in dependence of the tilting angle of the mirror is measured and the optimized mirror position for the lamp is determined sensitivity of tilt mirror adjustment intensity a u 2 angle deg Figure 6 5 influence of tilt mirror adjustment on light intensity The procedure should be performed subsequently for both lamps The optimized positions are stored independently for both lamps so that after setting the lamp lift in motion and thus changing the active lamp the mirror position is adjusted accordingly Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _______L 6 4 6 Final Adjustment and Configuration BARG OverView D Operation Lamps Status Brightness Active Lam p Mode Lamp Optimization Histor Wine Runtimes Reset Funtime Figure 6 6 Lamps menu Lamp optimization projector and i
53. gly Due to the fact that the lamps show tolerances in burner position and arc length multiple lamps with the identical relative brightness value will show differences in emitted brightness This can be checked by reading out the value of the direct illumination sensor DIS O In relative mode values can be entered in the range from 50 to 100 50 to 100 To modify the light level e Use the cursor keys to set the focus to the Value text field e Press Enter to activate e Use the left right cursor key to decrease increase the value or set a new value by means of the numeric keys on the Remote Control unit Since it is the result of the measurement the DIS value cannot be modified it is read only Set Brightness Absolute controlled mode Set Brightness Absolute amp Relative 5 Value Value Figure 6 25 Dialog box Set Brightness absolute mode activated O It is recommended first to run DIS calibration cf Error Reference source not found In this operation mode the dimmer is positioned by the brightness control algorithm utilizing the readout level of the direct illumination sensor DIS as feedback signal The control loop is triggered each time a new target value is entered It also becomes active after change of mode from relative to absolute The control loop stops once the target value is reached within an accuracy limit of 1 Typically this takes about 10 sec The target value is in same un
54. h ist Zuwiderhandlungen k nnen zu Schadensersatz verpflichten Alle Rechte aus der Erteilung eines Patents oder der Eintragung eines Gebrauchsmusters verbleiben bei uns Copyright 2004 by BARCO All rights reserved No part of this document may be copied reproduced or translated It shall not otherwise be recorded transmitted or stored in a retrieval system without the prior written consent of BARCO Guarantee and Compensation BARCO provides a guarantee relating to perfect manufacturing as part of the legally stipulated terms of guarantee On receipt the purchaser must immediately inspect all delivered goods for damage incurred during transport as well as for material and manufacturing faults BARCO must be informed immediately in writing of any complaints The period of guarantee begins on the date of transfer of risks in the case of special systems and software on the date of commissioning at the latest 30 days after the transfer of risks In the event of justified notice of complaint BARCO can repair the fault or provide a replacement at its own discretion within an appropriate period If this measure proves to be impossible or unsuccessful the purchaser can demand a reduction in the purchase price or cancellation of the contract redhibition All other claims in particular those relating to compensation for direct or indirect damage and also damage attributed to the operation of software as well as to other services provided by BAR
55. he ratio of the luminance of this color to the luminance of white which per definition equals 1 Gain if Parameter 1 Desired otherwise grayed out Gain should be set to 1 to prevent clipping Colour Red Green Blue Cyan Yellow Magenta White Value Value of coordinate in the x y chromaticity diagram CIE 1931 Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 ____LL_LLY 6 14 6 Final Adjustment and Configuration There are transformation algorithms between the different color spaces CAST allows to switch between the presentation of the coordinates in the u v color space CIE 1976 and the x y color space CIE 1931 The DLP Engine itself only knows the x y color space and requires that the values are entered as x y coordinates Only experienced personnel should edit this dialog There is a risk of severe damages Use CAST to do the color adjustment Due to the influence of the dimmer the values indicated by CAST and those listed on this dialog might slightly differ Changes become only active if Enabled is checked and if the menu is left by pressing the Exit button on the IR Remote Control Unit 6 6 4 2 White Peaking After changing the White Peaking Value the color adjustment has to be repeated The color correction model is only valid for one White Peaking Value setting Before setting the White Peaking value some background information on the generation
56. hite Peaking A dialog box is opened where the desired White Peaking Value can be entered White Peaking Figure 6 19 Adjusting the White Peaking Value A White Peaking Value of 10 is related to the max White Peaking Factor 1 8 incl white seqment spoke light recapture A White Peaking Value of 0 is related to the min White Peaking Factor 0 no white segment no spoke light recapture The intermediate values are set by means of the corresponding White Peak Value which are listed in the following table Please note that the table lists approximate values White Peaking Value White Peaking Factor 0 1 1 1 08 2 1 16 3 1 24 4 1 32 5 1 4 6 1 48 7 1 56 8 1 64 9 1 72 10 1 8 The White Peaking Value must not be changed after color adjustment The color correction model is only valid for one White Peaking Value setting The White Peaking Value has also impacts on the gamma valu cf Degamma Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 ____ 6 16 6 Final Adjustment and Configuration 6 6 4 3 Degamma Use Service Color Brightness Degamma to change the gamma value A list of the available gamma values pop up The current setting is indicated by a white dot Y Disabled Y Barco 03 Gamma 2 0 Y Barco 04 O Gamma 2 2 Barco 05 Gamma 2 3 Barco 06 Gamma 2 7 Y Barco 07 Y Barco 01 Y Barco 085 Y Barco 02 Y Barco 09 Figure 6 20 list of
57. ht Figure 5 18 Rear view horizontal position Use the adjustment screws for horizontal lens shift Figure 5 5 C Loosen the left and tighten the right screw to move the picture to the right Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 11 5 12 5 Geometric adjustment 5 13 Vertical picture shift The vertical picture shift may look like this or similar Figure 5 19 Rear view vertical picture shift Use the adjustment screws for vertical lens shift Figure 5 5 D Tighten the top and loosen the lower screw to move the picture downwards Figure 5 20 Use the adjustment screws for vertical lens shift Figure 5 5 D Loosen the top and tighten the lower screw to move the picture upwards 5 14 Locking the Projection Unit After the adjustment procedures the projection unit must be locked Turn the lock ring counterclockwise until it does not move any more don t tighten this ring too strong Lock the zoom and the focus adjustment by means of the fixation screws Tighten carefully the four securing screws of the lens Check if the position of the picture didn t change while locking the projection unit Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 5 13 5 15 Installing the shielding R840388 R840391 gi R840390 ed A W p R840392 R840393 R840394 5 Geo
58. ing slowly Red blinking slowly Mid LED status Red Static LED of Lamp Borom Green Static Yellow blinking fast Yellow blinking slowly Red blinking slowly Bottom LED Red Static status LED of Fan Green Static Red blinking slowly 7 Manual User Interface Meaning lamp is switched off cooled down lamp is switched on lamp is starting 15 minutes lamp is cooling down lamp is switched off cooled down an error occurred service required lamp is switched off cooled down lamp is switched on lamp is starting 15 minutes lamp is cooling down lamp is switched off cooled down an error occurred service required Fans are off Fans are on Fan error at least one fan failed service required Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 ________ 7 5 8 Hot Line 8 1 Address Feel free to contact us if you have any further questions e BARCO N V Projection Systems Europe Noordlaan 5 B 8520 Kuurne Phone 32 56 36 8282 Fax 32 56 368 251 E mail support controlrooms barco com Web www barcocontrolrooms com Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 8 Hot Line 8 1
59. into the right vertical profile turn it and fix it in a distance of approx 13cm measured from the floor O Make sure to tighten it fast to provide proper grounding e Attach the grounding label about 20mm above the connection point Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 3 15 3 Mechanical setup Checklist for proper grounding The fixation of the green yellow grounding cable is not sufficient to ensure proper grounding of the structure It must also be ensured that all metal parts of the structure are connected in a conductive way To ensure proper grounding all metal parts of the system have to be connected in a conductive way Therefore the corner brackets have to be fixed with nippled hammer bolts The same applies for the shielding due to the coating in addition spring washers have to be used Check the following items In case the result is negative corrective measurements have to be taken e Atleast one of the hammer bolts to fix the corner brackets for connecting the profiles is a nippled hammer bolt e The connection brackets between two columns are fixed with nippled hammer bolts e The shieldings are fixed with nippled hammer bolts and spring washers e All coated metal parts mounted into the structure apply at least one nippled hammer bolt and a spring washer e g support tray switch box OverView cPU67 DL In case no spring w
60. its as the DIS value If the DIS is calibrated to lux by appropriate setting of the DIS calibration factor then the target value is to be entered in lux If the dimmer fails to reach the target brightness because it is operated at it s upper or O lower limits an error message will show up Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ 6 20 6 Final Adjustment and Configuration Message Desired Brightness not achieved Figure 6 26 message at dimmer range limit Please note this error message does not indicate a dimmer failure O This message indicates that the dimmer cannot achieve the desired value but operates at his limits 100 or 50 respectively In this operation mode the commands of the Brightness menu are available BARES OverView D Operation Lamps stats Brightness Set Brightness Brighine ss Correction Top Figure 6 27 Brightness menu commands are available 6 6 4 5 Optical Dimmer OverView D uses a dimmer wheel with a variable slit The slit defines the light aperture of the light pipe entry Figure 6 28 Dimmer Wheel variable slit The amount of light emitted into the projection unit depends on the position i e slit width of the dimmer wheel Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 111 6 21 6 Final Adjustment and Configuration 0 9 0 8 0 7
61. left for 50 systems right for 67 systems Fixation screws for screen size adaptation lock filled with paint Zoom adjustment Focus adjustment 3 fixation screws for zoom lock Nn OT BP WU N 2 fixation screws for focus lock the focus ring still shows some clearance after locking This due to the mechanical design of the lens Anyway the focus is fixed The projection lens allows to zoom and to focus the picture The adjusted settings can be locked by means of fixation screws It is recommended to lock the lens only after the entire adjustment procedure has been done i After locking the focus adjustment ring and the zoom adjustment ring it might be necessary to correct again x y shift of the picture Even if locked the focus adjustment ring can be slightly turned Do not worry The focus Q is locked anyway Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 5 4 5 Geometric adjustment 5 4 Strictly prohibited devices Have a careful look on the following picture and remember O These screws shall NEVER be touched The projection lens is mounted on the housing of the projection engine screws are fixation screws for the entire projection lens or screws required for the All screws mounted on the level indicated by a black arrow are NOT to be touched These O Scheimpflug adjustment which has already be done in the factory Figure 5 3 r
62. metric adjustment SLDO1 Start mounting the side and top shielding Don t forget to remove the sealing of the double sided tape which is already on the shielding Use the nippled hammer bolts B361304 and spring washers to assure proper grounding All shieldings are fixed on the corner brackets with the drive fastener 9 In case coated material is fixed with hammer bolts to the profile Make sure to use the nippled hammer bolts and spring washers to provide proper grounding SLDO2 The rear shielding is mounted in the following way start with the engine shielding proceed with the mirror shielding and end with the top rear shielding The engine shielding is fixed by Sliding it downwards onto the 30 60 profile When the mirror shielding is placed loosen the screws of the exhaust pipe and make sure to lower the exhaust pipe to a maximum and tighten the screws Finish by placing the profile caps and the nut caps Complete the mirror shielding by attaching the Barco label on the respective rectangle 125mmx125mm on the plastic mirror cover Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 111 5 1 5 Geometric adjustment SLDO3 In case of a curved wall configuration additional rear curved shielding is foreseen this is standard for 3 5 and 8 Use the shown order of assembly aed ES Li lt _ A AS ale LNG a a
63. n height with adjustable feet is 1287 5mm Other heights are available on request with a minimum of 622mm finished ceiling minimum ecam nen ded space 350mm Weight distribution feet 10kg 35kg Row finished floor Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ ___ 2 4 2 Pre Installation requirements 2 9 Maintenance area A maintenance area of about 700mm must be provided behind each OverView cDG67 DL unit over the complete width This area must be permanently accessible The exact regulations for such a maintenance area can be obtained from the specifications for working premises The OverView cDG67 DL units can have linear or curved arrangements With a curved design the modular aluminum structure is built with angled connection plates The angle between two columns can vary between 0 and 8 Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ __ _ 2 5 2 Pre Installation requirements 2 10 Built in configuration When the OverView cDG67 DL is integrated in a
64. n the following chapter a description of the adjustment principles is given as well as some hints to carry out this procedure Switch on main power by pressing ON power switch Wait at least half a minute while the fan is blowing Switch on the lamp by pressing START lamp switch The last 3 steps have to be repeated for each module ADJO2 The sharpness of the image is adjusted by turning the focus ring The picture size can be adjusted by turning the picture size ring For further adjustment procedures do first the following steps loosen lightly the lens securing screws and turn the lock ring clockwise to unlock the engines 5 Geometric adjustment ADJO3 TRAPEZOID cam Fol gt Turn the adjustment screw V1 counterclockwise and V2 clockwise V1 clockwise and V2 counterclockwise until the vertical lines get parallel to the borders of the screen Turn the adjustment screw H1 counterclockwise and H2 clockwise H1 clockwise and H2 counterclockwise until the vertical lines get parallel to the border of the screen Turn the adjustment screw rotation clockwise counterclockwise until the horizontal lines gets parallel to the border of the screen Turn the adjustment screws for horizontal vertical lens shift C D tighten and loosen the opposite screws to shift horizontal vertical Turn the adjustment screw until the vertical lines gets parallel to the border of the screen After the adjustment procedures the DLP engine must be locked
65. nings must not be blocked or covered Exposing flammable or combustible materials into close proximity of this device could result in the spontaneous ignition of that material resulting in a fire For this reason it is absolutely necessary to leave an exclusion zone around all external surfaces of the device whereby no flammable or combustible materials are present The exclusion zone must be not less than 10 cm 4 e Do not allow anything to rest on the power cord Do not locate this product where persons will walk on the cord 1 2 5 Operation BARCO products are designed and manufactured to meet the most stringent safety regulations During operation the equipment radiates heat on its external surfaces and from ventilation ducts which is both normal and safe e Do not cover the equipment with any material while the equipment is in operation e Do not block the cooling fans or free air movement under and around the device e Keep flammable and combustible materials away from the device at all time In the event of fire use sand CO2 or dry powder fire extinguishers never use water on an electrical fire Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 __ _ 1 4 1 Introduction Do not allow anything to rest on the power cord Do not locate this product where people will walk on the cord To disconnect the cord pull it out by the plug Never pull the cord itself
66. or For a replacement power cord contact your dealer Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 1 3 1 Introduction If an extension cord is used with this product make sure that the total of the ampere ratings on the products plugged into the extension cord does not exceed the extension cord ampere rating Also make sure that the total of all products plugged into the wall outlet does not exceed 15 amperes A Mains lead AC Power cord with CEE 7 plug The colors of the mains lead are colored in accordance with the following code Green and yellow Earth safety earth Blue Neutral a Brown Line live Ie me E CEE 772 ss N BROWN f g LINE European Plug NEUTRAL BLUE ko ti d GROUND YELLOW GREEN Seh a gt uko Ena IEC 320 C13 B Power cord with ANSI 73 11 plug The wires of the power cord are colored in accordance with the following code Green yellow Ground ANSI 73 11 White Neutral Black Line live LINE BLACK NEUTRAL WHITE GROUND YELLOW GREEN 1 2 4 Placement Place the device in a well ventilated area away from sources of ignition and out of direct sun light Never expose this product to rain or excessive moisture Slots and openings in the cabinet and the back or bottom are provided for ventilation to ensure reliable operation of the product and to protect it from overheating these ope
67. or and the target value should be the same for all projection modules of the configuration in order to ensure a homogeneous brightness distribution Changing the brightness setting requires the following steps e Move to Service Color Brightnes Set Brightness e Press Enter to select The following dialog box is displayed to show to select the brightness setting and to see change the corresponding values Set Brightness Relative uncontrolled mode Set Brightness Absolute Relative 5 Value 270 Value 271 Figure 6 23 dialog box Set Brightness relative mode activated In this mode Value refers to a percentage of the maximum brightness This value corresponds to a specific position of the Optical Dimmer the position is determined by means of a look up table cf Error Reference source not found As mentioned above per factory default brightness is set to Relative and the dimmer is set to allow maximum brightness 100 In this operation mode the entries of the Brightness menu are grayed out since these refer to absolute values BARG OverView D Operation Lamps Status Brightness Figure 6 24 Brightness menu entries are grayed out Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 ____LLL_Y 6 19 6 Final Adjustment and Configuration The dimmer will be positioned immediately after entering a new target value and the related DIS value is adjusted accordin
68. or in a stable way The support must be able to hold the complete projector in a flat plane Minimum load of 80kg Take care of the available distance behind the wall The provided equipment and auxiliaries must be in line with the international safety regulations In case the display wall is integrated in a wall the gap between screen and wall must be constructed as detailed in the mechanical drawings front top and side view Typical 100mm before mounting of the trim The installation room must be sufficiently high Sufficient space recommended gt 200mm must be provided above the display wall A system responsible must be available during the installation for practical arrangements and safety reasons Free telephone access needs to be available for local communication 2 7 Footprint This footprint can be used to help you set out the wall configuration the room where the wall will be installed The circles at the side of the screen front are the rotation points for curved structures Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 ___ 7 3 2 Pre Installation requirements 2 8 Overall dimensions The installation room must be sufficient high Sufficient space recommended 350mm from top of the screen to finished ceiling must be provided above the OverView cDG67 DL units The functional depth of the OverView cDG67 DL is 814 mm the total depth is 954 mm The standard scree
69. ration How to determine the DIS Calibration Factor O The DIS Calibration Factor is determined by CAST The following description applies if there is urgent need to define the DIS Calibration Factor and if no CAST is available 0 0 To determine the DIS Calibratin Factor it is mandatory to set the DIS correction factor to O This has to be done in the menu Color Brightness Set Brightness To calibrate the DIS a lux meter is required Press the sensor of the lux meter on the screen Read the value of the lux meter Select Service Color Brightness Set Brightness Set Brightness Absolute Y Relative 50 Value 21 Value oF Figure 6 34 DIS value Make sure that Absolute is enabled Read the DIS value Now the DIS Calibration Factor can be calculated Brightness Luxmeter DIS Calibration Factor Brigh NESS pis Value Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ _ __ 6 25 6 Final Adjustment and Configuration 6 6 5 Orientation BARG OverView D Operation Lamps Status Brightness Service Projector address RS 232 baudrate Internal Patterns Color Brightness Front Table Maintenance Front Ceiling Rear Table Peza Rear Ceiling Disable IR d d Lamps Version More Figure 6 35 Service menu Orientation For DLP projection engines incorporated in OverView D systems this menu en
70. ress key displays projector address 005 then press 5 digit button on the RCU to set the RCU s address to match the projector s address Do not press 005 digits This will address the remote control to 0 and control all projectors in the room If the address is not entered within 5 seconds the RCU returns to its default address zero address and control all projectors in the room Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 200 gt 6 8 6 Final Adjustment and Configuration 6 6 1 2 How to Program an Address into the RCU Press the ADDRESS key recessed key on the RCU with a pencil and enter the address with the digit buttons within 5 seconds after pushing the address key That address can be any digit between 0 and 9 6 6 2 RS232 baudrate Brightness Service Projector address BS 232 baudrate 2500 Internal Patterns 19200 Color Brightness t 38400 Orientation d 115200 CE b b Maintenance m y r Pi a Po Disable IF Lamps Version More Figure 6 13 Service Menu RS232 baud rate For servicing reasons higher baud rates can be selected Please keep in mind that with firmware 2 x 115200 should only be selected in a single projector connection Standard baud rate which is supported by wall management software is still 9600 However projectors with Firmware 3 x might be operated with the OverView Control Manag
71. rews M6x7 Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 __1__1__1__1__1_ 3 19 3 Mechanical setup ENGO5 For final adjustment of the projection unit you need to remove the engine shielding ne this panel for projector adjustment 3 20 Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 3 Mechanical setup 3 8 Cabling of the engine CBLO1 AIR TUBES SERIAL CABLE MALE FEMALE STRAIGHT Look at the above general connection diagram to connect all cables and air tubes When using optical fibre data cables please note that they may not be bent to a curvature with a bend radius less than 15 4cm As soon as the illumination unit and the projection unit are connected by the signal cable and or the power cable DO NOT disconnect either of these cables under operation or in standby Disconnect only when the system is completely powered off all LEDs are off Otherwise the trinamic board of the IU will be damaged Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 4 Taking into operation 4 Taking into operation 4 1 Running the fans Before taking the system into operation it must be OP01 ensured that the fans and the hoses are dust free
72. ror occurs 120 Diagnostics Trinarmic Formatber CIS SMPS PEF 8574 SMPS PCF 85 91 SMPS PCF 8592 SMPS PCF 25 91 Fan Lift Fan Lamp Status Ctrl 1 Status Ctrl 2 Status Ctrl 3 DVT E2PROmM1 DVT E2PROM2 DWII2c Swith DWT OLE PH POF DYI SAC SL PEF DWT SAC SL POF igure 6 48 I2C Diagnostics information Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 200 gt 6 33 6 Final Adjustment and Configuration 6 6 9 Dimmer Sensor Power The dimmer sensors requires to be powered only when performing a reference search Thus during normal operation the life time of the dimmer sensor could be enhanced by shutting off the power However the effects of this have not yet been investigated thouroughly therefore it is recommended NOT to change the default setting which is enabled BARCO OverView D Operation Lamps Status Brightness Se Projector addr BS 232 baudrate Internal Patterns Color Brightness Orientation Maintenance Color Wheel Alignment Restore Default Settings p Freeze Program Input Board Disable IR Restart Projector Lamps Lamp Driver Version Mo Source Counter Ia Diagnostics More Dimmer Sensor Power igure 6 49 Service Maintenance Dimmer Sensor Power Disable Dimmer Sensor Power only on special request special advise Dimmer Sensor Power Disabled Enabled igure 6 50 enabl
73. s immediately triggered by selecting the command Lamp Optimization This procedure optimizes the coupling of the active lamp into the optical system of the O During this procedure the display gets dark for about 30seconds e Use the cursor keys to highlight Lamp Optimization e Press ENTER to select If Operation Message Box is enabled the following message box is displayed Lamp Optimization Lamp Optimization For top lamp in progress Please Wait Figure 6 7 Lamp optimization in progress O The procedure should be performed subsequently for both lamps All other steps to configure the system have to be done in the service menu Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 200 gt 6 5 6 Final Adjustment and Configuration 6 6 Access to the service menu To access the service menu of the OSD proceed as follows Start the OSD Move the cursor to Brightness BARCO OverView D E A Brightness Figure 6 8 first step to activate the Service Menu Enter the access code via the numeric keys on the IR Remote Control Press Enter to complete The Service menu entry is shown Move the cursor to highlight Service Press Enter to select The following menu items are displayed BARCO OverView D Operation Lamps Status Brightn Projector addr RS 232 baudrate Internal Patterns Color Br ight Orientation Maintenance Save Fr Disable IR Lamps Version More
74. se circuits have to be fused 16A typical for 220V The number of projectors starting up concurrently must be limited One could for instance install an automatic circuit that starts up all the projectors in batches per circuit leaving 3 second between the different batches Not standard delivered The projectors should be kept away from strong sources of magnetic fields Fused circuits for the graphic generator equipment have to be installed The number depends on the amount of installed equipment Some of the graphic generator equipment functions as a Unix workstation It must not be powered off without carefully closing all the applications If these units are switched off during normal operation without this precaution there is a risk that the file system gets corrupted and it becomes unusable Therefore it is strongly suggested to provide a non interruptible Power Supply UPS to power these units Additional grounding points must be foreseen for the display wall construction racks and other mechanics Power outlets for installation purposes are required as well All connections power network should be available and functional before start of the installation 2 2 Environmental conditions 2 2 1 General conditions The temperature and the humidity in the control room have to be controlled on the both sides of the wall The screens require a temperature between 17 and 27 dgc and humidity between 40 60 RH The maximum temperature flu
75. se the two power strips may not be connected in series Always take care that the max rating of the ip i mains voltage mains voltage pe CEREA 220V 110V Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 3 14 3 Mechanical setup 3 6 Grounding the structure and fixation of the structure to the floor GRDO1 At least every second column of a display wall has to be grounded The connection of the grounding wire to the power net of the building has to be done by a qualified electrician of the customer The grounding kit R764734 comprises the green yellow grounding cable 5m the necessary fixation material and the label The grounding kit includes a nippled hammer bolt which digs into the profile In addtion the contact washer also has pins to provide proper contact The zinc plated nut is screwed about 10mm to the hammer bolt Grounding is done on the rear side of the structure The grounding wire is mounted to the right vertical profile of each column in case of the Atlas C4 systems on the shared vertical profile e To ground a column proceed as follows e Arrange the fixation material in the correct order e Unscrew the nut from the hammer bolt e Insert the contact washer pin side to hammer bolt head e Subsequently insert the annular cable lug then the plain washer e Loosely attach the nut e Insert the pre assembled hammer bolt
76. ser B263667 M8x10 to fasten the profiles Do not tighten the screws already Make sure that the 30 30 profile can still be rotated around its axis MIRO2 For safety reasons use protective gloves when installing the mirrors Hook the mirror into the upper slots of the front mirror brackets and mount the mirror adjustment assembly on the rear plate with two M6x16 B3631669 Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 3 11 3 Mechanical setup MIRO2 Pull the mirror against the horizontal profile and bolt it onto the inside of the structure as shown on the right MIRO3 Use the mirror jig to place the mirror in its nominal angular position by means of the mirror adjustment bracket Don t forget to put S all mirror adjustment brackets into zero y position i N 2 oa r res r IN IN Za mirror jig UM lr 4 f A p Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ 3 12 R840389 3 Mechanical setup MIRO4 Place the front and bottom shielding remove the tape shielding and position the shielding on to
77. sible 5 7 Focus adjustment The sharpness of the outlines of the squares test pattern is adjusted by turning the focus adjustment ring Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 H______1___1_ 5 7 5 Geometric adjustment 5 8 Picture size The wrong picture size looks like this or similar Figure 5 8 Rear view picture size too big Turn the zoom adjustment ring at the lens Figure 5 1 counterclockwise to decrease the size of the picture Figure 5 9 Rear view picture size too small Turn the zoom adjustment ring at the lens Figure 5 1 clockwise to increase the size of the picture Figure 5 10 Rear view picture size o k Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 200 ___LL____Y_ 5 8 5 Geometric adjustment 5 9 Vertical Trapezoid A vertical distortion looks like this or similar Figure 5 11 Rear view vertical trapezoid Turn the adjustment screw V1 counterclockwise Figure 5 5 and V2 clockwise until the vertical lines gets parallel to the border of the screen Figure 5 12 Rear view vertical trapezoid Turn the adjustment screw V1 clockwise Figure 5 5 and V2 counterclockwise until the vertical lines gets parallel to the border of the screen Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 __ __ 5 9 5 Geometric adjustment 5
78. sired colorc can be applied Selecting Service Internal Patterns RGB displays the following dialog box KM DD AA EA O 44 E gt b gt Mda E gt Dy Figure 6 15 dialog box to define the desired color On this dialog box the values for red green blue can be entered by means of the arrow buttons Arrows pointing to the left decrease a value arrows pointing to the right increase a value Clicking on a single arrow increases decreases 4 the value per 1 Clicking on the double arrows increases p decreases 4 4 the values per 64 Clicking on the right most left most arrow sets the value to the maximum 1023 or minimum 0 Using the All button will manipulate all individual RGB settings to be equally increased or decreased respectively Besides the dialog box to enter the RGB values a square frame is displayed to indicate the center of the screen Both the RGB value dialog box and the square frame can be switched on off by pressing O the text button on the IR Remote Control Unit 6 6 3 2 Understanding the color values Since the ASIC allows 10 bit input per color on this dialog box the values are in the range from 0 to 1023 The relationship to 8 bit input DVI RGB Data is given by R G B 4 R 1 4 G 1 4 B 1 for example 511 439 1019 128 110 255 extern extern ASIC application specific integrated circuit Barco OverView cD 67 DL R5976624 installation manual R
79. sist on genuine BARCO replacement parts Never use non BARCO replacement parts as they may degrade the safety of this device Call for service in the following conditions e When the power cord or plug is damaged or frayed e If liquid has been spilled into the device e lf the product has been exposed to rain or water e lf the product does not operate normally when the operating instructions are followed e Ifthe product has been dropped or the cabinet has been damaged e Ifthe product exhibits a distinct change in performance indicating a need for service When replacement parts are required be sure the service technician has used original BARCO replacement parts or authorized replacement parts which have the same characteristics as the BARCO original part Unauthorized substitutions may result in degraded performance and reliability fire electric shock or other hazards Unauthorized substitutions may void warranty Upon completion of any service or repairs to this unit ask the service technician to perform safety checks to determine that the unit is in proper operating condition 1 2 7 Unpacking of devices Note advises on the packaging for unpacking 1 2 8 Modification of devices Mechanical or electrical modifications must not be made to the devices BARCO is not liable for damages resulting from modified devices Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _____ 1 5 1 Intro
80. stment and Configuration BARG OverView D Operation Lamps Status Brightness Service RS 232 baudcrate Internal Patterns Color Brightness Orientation Maintenance m y oe Disable IF Lamps Version More Figure 6 11 Service Menu Projector Address The projector address and the common RC5 address is displayed Projector Addresses Projector Address 5 Common RCS address o Figure 6 12 Projector Address and common address The projector address is set to five and the common RC5 address is zero Therefore the projector will listen to commands received from an IR Remote Control unit with the address 5 and with the address 0 To change a value e Move the cursor key to the respective field e Enter the new value by means of the numeric keys of the IR Remote Control For an application it might be useful to have the Display Wall split into two parts one O with the common RC5 address 0 and one with the common RC5 address 1 6 6 1 1 Displaying a Projector Address by means of the Remote Control Unit Press the ADDRESS key recessed key on the RCU with a pencil The projector s address will be displayed in a Text box This text box disappears after a few seconds To continue using the RCU with that specific address it is necessary to enter the same address with the digit buttons address between 0 and 9 within 5 seconds after pushing the address key For example if the Add
81. the MITOS it a 3 11 3 6 Grounding the structure and fixation of the structure to the flOOT ooocconccncconccononanonncnononononononoos 3 15 D7 MMS LAIN tie enMi ees 3 18 SCI R EEE I AEEA a a ESO 3 21 Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 ___ vi TIRO ICO OPE ION A R 4 22 A OS ae ar chet hacen hata E alac Salalah eal teehee 4 22 42 serung Pe Lamp Modules ta lo Me emir 4 22 a al Une lt CO hl CE MAID OVET aiana a ana ah nce tiitcesiat ass 4 24 5 Geometticadustmenti ninio Aaa 5 1 O IN ON 5 1 5 2 The projection lens for SXGA System Ssss an a a nono nana E ERE ncnr naa nana ranas 5 3 5 5 Me projection lens for XGA SO A A A A AA 5 4 5A SUICUY PFOMIDILC devices ninia 5 5 O Ay UE O me Cee eee ee 5 6 A O O 5 7 A A eet ae lal ac ta acct hai a elidel ee hale ie atten 5 7 3O PICU SIZ Os sito iadan canst ceasaasa deen none vagunnevsaban dr 5 8 E MA cane in aan eee Onan een Ga Gee 5 9 5 10 Horizontal trapezoid A 5 10 PF E Qe AO 5 11 STZ TAOLIZ ONL PIU a no a a 5 12 SASV D O O ieee OA 5 13 5 14Locking the Projection Un linia ta 5 13 SS MAS taln Me SAO xs atte chet a stee AN cd eet T N 5 1 5 16 Installing the standard and design TIM it 5 3 6 Final Adjustment and Configurati0N cscssesssseessssesesessecesessecessesesessesesessesesesseseseeseaeseeseseseenes 6 1 LIA By era DIE OPE PAC O O O NO 6 1 62 Me 1 Remote Conta Ue lion 6 1 621 TETMINOIOOY OF RCU COTO
82. the White Peaking value on the gamma curve 100 White Peaking 0 ES 80 a D 2 y 1 0 G D 2 40 E y F 2 8 Y 20 0 0 32 64 96 128 160 192 224 RGB Input Value Figure 6 21 gamma curves no White Peaking 100 White Peaking 10 80 3 60 YN y 1 0 z 40 a oO 2 w Ko or 213 0 0 0 32 0 64 0 96 0 128 0 160 0 192 0 224 0 RGB Input Value Figure 6 22 gamma curves full white peaking Since the effective gamma values are enlarged due to White Peaking the default setting for OverView D is 2 0 Please note that this effect only applies for white and gray R G B The primary colors and secondary colors are not affected for those the set gamma value is exactly the effective gamma value Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _____Y 6 18 6 Final Adjustment and Configuration 6 6 4 4 Set Brightness Before setting brightness it is recommended that Lamp Optimization cf Lamp O Optimization has been performed at least once per lamp Use this menu to switch between a relative brightness setting and an absolute brightness setting Per factory default in new systems the value is set to relative no brightness O information about the used lamp is available In running system the correct setting is absolute brightness measured by means of the DIS sens
83. the structure Use the drive fastener to fix the shielding onto the corner brackets Make sure to use the nippled hammer bolts and spring washers to assure proper grounding Q In case coated material is fixed with hammer bolts to the profile Make sure to use the nippled hammer bolts and spring washers to provide proper grounding Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ _ 3 13 3 Mechanical setup PCLO1 Install the multiple power strip B365010 A oe ss Since the illumination unit is located at the right side the power strip is best to be placed on the right z profile This power strip includes 6xIEC 320 sockets PCLO2 a For later cabling of the illumination unit see schematics The power strip includes 6xIEC 320 sockets and is rated for a max current of 10A This means In countries using 220V up to six power cables of OverView D could be plugged in i e the illumination units of one column can all be connected into one power strip 3 In countries using 110 V only up to three power cables of OverView D illumination units can be plugged into one power strip Therefore for display walls higher than 3 rows a second power strip per column has to be installed Of cour
84. tion is related to Measured CAST provides this information by measuring the factory colors The ASIC then needs to know the target color coordinates for all primary colors for all secondary colors and for white R G B C M Y W 7 primary colors processing On the Color Coordinate Adjustment dialog this information is related to Desired CAST provides this information by determining the Target Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ 6 13 6 Final Adjustment and Configuration Selecting Service Color Brightness Color Coordinate Adjustment displays the following dialog box Color Coordinate Adjustement Disabled Enabled Parameter 1 Measured e Parameter 2 a aan x Coordinate e Colour Value Figure 6 18 dialog box Color Coordinate Adjustment The dialog box refers to the active lamp O The data need to be set individually for each lamp The Enable Disable selection always refers to both lamps Click on the arrow next to the respective text field to get a list of the available options Parameter Possible value Parameter 1 Measured Desired Parameter 2 X coordinate should be within the measured triangle of the factory colors Y coordinate should be within the measured triangle of the factory colors Luminance if Parameter 1 Measured otherwise grayed out The relative luminance of a color is defined as t
85. try is irrelavant The orientation of the projection engine is fixed and defined as Front Ceiling However in case your picture is displayed upside down it might be recommended to check the orientation set on this menu The other orientations are required for test situations with the engine NOT installed in the structure e To check the set orientation proceed as follows e Move the cursor keys to highlight Orientation Press Enter to select The possible orientations are displayed The actual orientation is indicated by a white dot O For OverView D series the only correct orientation is Front Ceiling Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 __ 6 26 6 Final Adjustment and Configuration 6 6 6 Maintenance BARCO OverView D Operation Lamps Status Brightness Service Projector address RS 232 baudrate Internal Patterns Color Brightness Orientation Maintenance Save d Color Wheel Alignment Restore Default Settings EZE Program Input Board Disable IF Restart Projector Lamps Lamp Driver Version Ho Source Counter 2C Diagnostics More 2 Dimmer Sensor Power Figure 6 36 Service menu Maintenance 6 6 6 1 Color Wheel Alignment This setting specifies the delay value between the color wheel index signal and the DLP electronics Each step equals 100 ns The value is specific for each color wheel
86. vided concerning the operation of control room solutions from BARCO Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 2 __________ 1 1 1 Introduction 1 1 Styles and Symbols The typographic styles and the symbols used in this document have the following meaning Bold Labels menus and buttons are printed in Bold font Condensed Links to both other chapters of this manual and to sites in the Internet are printed condensed In the on line version of this manual all hyperlinks appear teal Cone Names of files and parts from programs are printed in the Courier font Courier bold Inputs you are supposed to do from the keyboard are printed in Courier bold font De CWO If you do not heed instructions indicated by this symbol there is a risk of damage to the equipment If you do not heed instructions indicated by this symbol there is a risk of electrical shock and danger to personal health If you do not heed instructions indicated by this symbol there is a risk of damage to parts which are sensitive towared electrostatic charge If you do not heed instructions indicated by this symbol there is a risk to get harmed by sharp objects If you do not heed instructions indicated by this symbol there is a risk that parts may explode If you do not heed instructions indicated by this symbol there is a risk that hot parts impact persons or objects The sheet icon indicat
87. vision 04 May 2006 __ 6 43 6 Final Adjustment and Configuration The correct Authorization Code opens a dialog box to enable On disable Off Hot Standby Mode Release Hot Standby OFF On Figure 6 67 dialog box to switch on off Hot Standby functionality In case Hot Standby is enabled it is mandatory to inform Project Management Hot Standby requires special actions e g with service contracts Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _____LLLY 6 44 7 Manual User Interface 7 Manual User Interface The manual user interface located at the rear of OverView D includes the switches of the illumination unit A B C the LED s of the illumination unit and the LED s of the lamp doors The manual user interface is intended to operate the projection module when servicing The trained Barco support technicians can analyze errors by evaluating the status of the LEDs Figure 7 1 detail of rear view OverView mD 7 1 Power Switch The power switch A connects disconnects the projector from the mains Once switched on the projector should be disconnected from the mains only for servicing Do not press the power switch while the projector is running The projector has to be O switched to Standby first Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 _ _ 71 7 2 Standby Switch 7
88. y means of the straight brackets Assemble the vertical trim by clicking it on to the structure by means of the ID fix Finish the trim by mounting the finishing corners Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 gt 5 3 5 Geometric adjustment TRMO2 After this step you can put the self adhesive Velcro on the front of the standard trim This Velcro is found on the design trim parts Make sure to put the right pieces in the right place TRMO3 R823613 R824241 The design trim is basically mounted in the same way as the standard trim The main difference is the way to attach the profiles this is done by means of self adhesive Velcro fastening tape To attach the design trim proceed as follows Arrange the required parts pre assemble the trim profiles by means of the brackets Then push the design trim firmly onto the standard trim Barco OverView cD 67 DL R5976624 installation manual Revision 04 May 2006 __ 5 4 6 Final Adjustment and Configuration 6 Final Adjustment and Configuration After the set up of the Display Wall the system has to be fine adjusted This is done via the IR Remote Control and the OSD or the respective commands via the RS 232 Remote Control 6 1 Data cables When connecting the
Download Pdf Manuals
Related Search
Related Contents
MーTSUBーSHー Digitus DN-19 MA-SRV-47U mounting kit Soundmaster SCD2100TI CD radio IPC series IP camera user manual DocuMate 765 Scanner Benutzerhandbuch REFERENCE GUIDE Aero 2100 Series Color Palm Seagate 8-Bay Rackmount NAS Manual do usuário Samsung ML-2510 User's Manual USER'S MANUAL version 1.0 SAFETINEX - Contrinex Copyright © All rights reserved.