NorthStar™ Encoder Installation Manual
Contents
1. Na se Customer Service f X DYNAPAR Headquarters 1675 Delany Road Gurnee IL 60031 1282 USA Technical Support Tel 1 800 234 8731 Fax 1 847 782 5277 northstar techsupport dynapar com Tel 1 800 873 8731 Fax 1 847 662 4150 custserv dynapar com Visit us at www dynapar com NorthStar brand SERIES EN44 Document No 702828 0001 Revision Level A April 2 2012 Encoder installation Manual Zone 1 Hazardous Area Rated Encoder Ex ia mb e IIC T4 Gb Certification No Sira 09ATEX5172X V cE General The following instructions are meant to assist in proper installation of the NorthStar Series EN44 Sealed Hubshaft Encoder The encoder is a harsh duty speed and position transducer that when mounted to a rotating shaft produces output pulses that are directly propor tional to the shaft speed and direction The encoder is attached to the motor shaft via a stainless steel flexible coupling that compensates for motor shaft end play and run out The clamp is also electrically isolated from the encoder to ensure motor shaft currents do not ground through the encoder bearings Due to this specialized coupling special precautions must be taken during installation as outlined in this manual The EN44 was designed specifically for Hazardous Area rated applications common in Oilfield operations Proper operation is dependant upon installation by suitably trained personnel in accorda
2. 90 C Variation 1 This variation introduced the following changes i A 26 V rated version of the equipment was introduced consequently the ratings in the description were updated to recognise this change This certificate and its schedules may only be reproduced in its entirety and without change Sira Certification Service Rake Lane Eccleston Chester CH4 9JN England Tel 44 0 1244 670900 Page 2 of 3 Fax 44 0 1244 681330 orm 9400 Issue1 Email info siracertification com Web www siracertification com Application Assistance 1 800 234 8731 847 662 2666 Page 9 14 14 1 14 2 15 15 1 15 2 15 3 16 17 17 1 17 2 17 3 17 4 sira CERTIFICATION SCHEDULE EC TYPE EXAMINATION CERTIFICATE Sira 09ATEX5172X Issue 1 DESCRIPTIVE DOCUMENTS Drawings Refer to Certificate Annexe Associated Sira Reports and Certificate History _Issue Date _ Report no Comment J 0 17 September 2009 R59A16953A The release of the prime certificate 1 22 October 2009 R20998A The introduction of Variation 1 SPECIAL CONDITIONS FOR SAFE USE denoted by X after the certificate number All cable entry holes shall be fitted with either an ATEX certified Ex e cable gland or an ATEX certified Ex e plug The type of cable and the cable glands selected shall have temperature ratings of at least the maximum ambient temperature of where the equipment is ins
3. Page 2 CABLE PROTECTION Run the encoder cable through a dedicated conduit not shared with other wiring Use of conduit will protect the cable from physical damage and provide a degree of electrical isolation If a conduit is not practical use wire trays to protect cable If there is not a practical way to protect the cable you may consider using armored cable See section 9 of the IEC EN60079 14 standard as applies to Increased Safety installations Do not run the cable in close proximity to other conductors that carry current to heavy loads such as motors motor starters contactors etc This practice can induce electrical transients in the encoder cable potentially interfering with reliable data transmission CAUTION Unused encoder signal wires must be individually insulated and under no circumstances be in contact with ground voltage sources or other signal lines Zone 1 Wiring Considerations CAUTION The Encoder wiring configuration for the EN series encoder is different than an Intrinsic Safe wiring configuration No IS barrier Zener or Galvanic is required when using the EN series encoder Barriers may prevent proper operation and or frequency performance Damage to the encoder may occur if the encoder output is connected to an IS barrier When selecting an encoder consider the power supply to the encoder and input voltage to your data acquisition PLC or drive system Cable length and RPM max will determin
4. 1 T2 T3 and T4 3 The equipment is only certified for use in ambient temperatures in the range 50 C to 100 C and should not be used outside this range 4 The certificate number has an X suffix which indicates that the certificate contains one of more special conditions for safe use Those installing or inspecting the equipment should refer to this section of the certificate 5 The equipment has not been assessed as a safety related device as referred to by Directive 94 9 EC Annex Il clause 1 5 6 The equipment has not been assessed as a safety related device as referred to by Directive 94 9 EC Annex Il clause 1 5 7 Installation of this equipment shall be carried out by suitably trained personnel in accordance with the appli cable code of practice 8 Repair of this equipment shall only be carried out by the manufacturer or in accordance with the applicable code of practice 9 The certification of this equipment relies on the following materials used in its construction Enclosure Case material type Anodized aluminium Other external parts and Shaft material Aluminium or SST Potting Compounds Silicone Based Sealing Orings Silicone type Shaft seals Viton If the equipment is likely to come into contact with aggres sive substances then it is the responsibility of the user to take suitable precautions that prevent it from being adversely affected thus ensuring that the type of protection
5. 1 4 20 x 1 Encoder D3 345 000 Mounting Screw 6 required Apply a small amount of PILOT threadlocker to the screw threads STEP 6 While observing the proper orientation of the cable exit slide the encoder straight over the motor shaft extension and engage the encoder s Flex Coupling Note again shaft engagement is MIN 0 47 MAX 0 83 110 MIN PILOT DEPTH 6 20 X F 0 10 X 1 4 20 X 10 MIN 47 MIN TO EQUALLY SPACED ON 83 MAX SHAFT LENGTH A O3 937 B C EN44 COUPLING CLAMP INSTALLATION Note Please refer to this figure when performing Installation Steps 7 11 OSHAFT CLAMP SCREW i J SHAFT CLAMP ACCESS PLUG COUPLING LOCATING HOLE FLEX COUPLING LOCATING SCREW Application Assistance 1 800 234 8731 847 662 2666 Page 4 i MECHANICAL INSTALLATION Note Please refer to EN44 Coupling Clamp Installation figure previous page when performing Installation Steps 7 11 STEP 7 Install the six Encoder Mounting Screws using the 3 16 hex key and torque to 75 inch pounds STEP 8 Using the 5 32 hex key tighten the Shaft Clamp Screw Torque to 36 inch pounds Remove the 5 32 hex key CAUTION The motor shaft must NOT be rotated until Step 9 below is performed or damage to the encoder flex coupling will result STEP 9 Using the 5 32 hex key completely remove the 10 32 x 1 5 Flex Coupling Location Screw This screw is no longer needed for installation instead repla
6. 1244 670900 F 9400 1 Faga 2as Fax 44 0 1244 681330 orn seue Email info siracertification com Web www siracertification com Page 10 Application Assistance 1 800 234 8731 847 662 2666 Certificate Annexe Certificate Number Sira 09ATEX5172X S il ra Equipment Optical Encoder Applicant Dynapar Corporation CERTIFICATION Issue 0 Drawing Sheets Rev Date Sira stamp Title 114507 0001 1 of 1 200869 0001 10f3 200869 0003 30f3 200870 0001 tof 1 200871 0001 tof 1 ioti 1of1 Rev B_ 17Sep09 LABEL 4428 EN ATEX D__ 15Sep09 DWG ASSEMBLY EN ATEX D__ 15S5ep09 DWG ASSEMBLY EN ATEX 1D 15Sep09 DWG ASSEMBLY EN ATEX 15S5ep09 DWG ARTWORK EN ATEX 15Sep09 ATEX NON BARRIER POTTING INSTRUCTIONS _ A _ 15S5ep09 ASIC MODULE ASSEMBLY 200885 0001 502947 0001 Issue 1 Drawing Sheets _ 114507 0002 200871 0001 Date Sira stamp B__ 21 Oct 2009 Label 4428 EN ATEX D__ 21 Oct 2009 Dwg Schematic EN ATEX This certificate and its schedules may only be reproduced in its entirety and without change Sira Certification Service Rake Lane Eccleston Chester CH4 9JN England Tel 44 0 1244 670900 Form 9400 1 Hage 108 Fax 44 0 1244 681330 R oe Email info siracertification com Web www siracertification com Application Assistance 1 800 234 8731 847 662 2666 Page 11 i Ne fa Z z
7. 60079 7 2007 Increased Safety EN 60079 18 2004 Encapsulated Before installation or operating in a Hazardous Area the installer must be trained and familiar with hazardous area installation and IEC EN 60079 14 standards Note Encapsulation techniques are an improve ment over flameproof 60079 1 Specifications requiring heavy XP metal enclosures to contain a flame Encapsulation eliminates the air around the electronics preventing ignition and allowing smaller lightweight enclosures to be used in the design Table of Contents Topic Page Description amp Table of Contents cceceeeeee 1 Electrical Installation cccccccecceeeeeeeeeeeeeeees 2 3 Mechanical Installation ccccccccssessssssseeseseees 4 5 Specifications ceccecceeeeeeeeeeeeeeeeeeeneeeseeeeeeenaeeeeaes 6 SIRA User Instructions ccccecccceessseeecceeeseeeeenes 7 SIRA Certification cccccccccccccceseessesseeaeeeeees 8 11 Declaration of Conformity ceeeeeeeeeeeeeeeees 12 ELECTRICAL INSTALLATION CAUTION Before installation ensure power is off and locked out Failure to do so may damage encoder and or cause a spark or explosion Electrical Installation must be performed by an individual that is trained and familiar with hazardous area installation Standards that apply are IEC EN 60079 14 and other applicable wiring codes that apply to the specific location of the installation Please f
8. C 7 26VDC see ordering information Input Current 65mA max not including output loads Outputs TC4428 Line Driver Output Current Refer to Ordering Information Table Code 4 ATEX Output Format Code 4 Option 0 or 2 125mA max per channel Code 4 Option 1 or 3 10mA max per channel 100 C 15mA max per channel 90 C Frequency Response 125 kHz data amp index Termination Terminal block Ex screwless w spring cage clamp Interface HAWKE type E increased safety rated gland for armored and non armored cables HAWKE Part Numbers Non Armored Gland HAWKE 501 421 A 3 4 NPT S accepts 8 5 13mm cable OD Armored Gland HAWKE 501 453 UNIV A 3 4 NPT accepts 12 5 20 5mm cable OD Models MECHANICAL Mechanical Interface Stainless steel shaft clamp Mating Shaft Length 0 47 to 0 83 11 9mm to 28 1mm Coupling 16mm flexible Shaft Speed 6000 RPM max Bearings 6107 Bearing life 5 x 108 revs at rated shaft Loading 5 x 10 revs at 10 of rated shaft loading manufacturers specs Housing Material Aluminum Alloy Black Anodized Disc material Mylar Weight 6 lb 6 oz typical ENVIRONMENTAL Operating Temperature 50 to 100 C See tNote Storage temperature 50 to 100 C See tNote Shock 50G s for 11msec duration Vibration 5 to 2000Hz 20 G s Humidity 100 Enclosure Rating IP67 t Note Armored Gland high temperature specification limited to 80 C Specifi
9. DYMAPAR _ ds rir EC Declaration of Conformity Dynapar Corporation declares under our sole responsibility that the products s listed below conform to the relevant provisions of directive 94 9 EC of 23 March 1994 Product s Optical Encoder Series EN42 and EN44 Notified Body SIRA Certification Service 0518 Rake Lane Eccleston Chester CH4 9JN Manufacturer Dynapar Corporation 1675 Delany Road Gumee IL 60031 USA Conformity has been demonstrated with reference to the following documentation EC Type Examination Certificate SIRA O9ATEX5172X Issue 1 Compliance with the Essential Health and Safety requirements has been re assessed to the following standards with no changes required to the product EN 60079 0 2006 Cane EERIE OP eo EN 60079 7 2007 OPTICAL ENCODER EN 60079 11 2007 Ex ia mb e IIC T4 Gb Ta S0 TO 100 C EN 60079 18 2004 U 15V EN 60079 0 2007 CERT No Sira O9ATEX5S172X nes Dynaear corporation asi8 Gurnee lllinois USA OPTICAL ENCODER Ex ia mb e IIC T4 Gb Ta S8 TO 148 C U bY CERT No Sira BAATEXSI72EX The product is also in compliance with EMC Directive 2004 108 EC and the requirements of the EN 61326 standard Used for guidance in respect of marking Date FLAG David Hill 11 18 09 David Hill Operations Manager Dynapar Corporation 1675 Delany Road Gurnee Illinois 60031 Application Assistance 1 800 234 8731 847 662 2666 Page 12 PE l l
10. cations subject to change without notice All product and brand names are trademarks of their respective owners All rights reserved NorthStar brand is a trademark of Dynapar All rights reserved 2012 Dynapar Mylar is a registered trademark of Dupont Ordering Information To order complete the model number with code numbers from the table below Code 1 Model Code 2 PPR Code 3 Bore Size Code 4 ATEX Output Format Code 5 Termination OOOO O O O Ordering Information EN44 ATEX Zone 1 Hubshaft Encoder A 16mm 0 Differential AB 7 15V in 7 15V out 1 Differential AB 7 26V in 5V out 2 Differential ABZ 7 15V in 7 15V out 3 Differential ABZ 7 26V in 0 No Gland 1 Ex Gland for non armored cables 8 5 13 5mm OD 2 Ex Gland for armored cables 12 5 20 5mm OD Nout See tNote See Electrical Specifications for Details t Note Armored Gland high temperature specification limited to 80 C Application Assistance 1 800 234 8731 847 662 2666 Page 6 pp SIRA USER INSTRUCTIONS 1 The certification marking is as follows USA OPTICAL ENCODER OPTICAL ENCODER Ex la mb e IIC T4 Gb Ta S0 TO 100 C Ex la mo e IIC T4 Gb Ta 50 TO 100 C U 15V U 26V CERT No Sira O9ATEXS172X CERT No Sira O9ATEXS172X 2 The equipment may be used in Zones 1 and 2 with flammable gases and vapours with apparatus groups IIA IIB amp IIC and with temperature classes T
11. ce with the shorter 10 32 x 7 8 screw Obtain the 10 32 x 7 8 SHCS from the hardware kit this screw has an o ring under the head Apply a small amount of threadlocker to the screw threads Using the 5 32 hex key install the screw into the Coupling Locating Hole and torque to 20 inch pounds The purpose of this shorter screw is to block the hole while in operation STEP 10 Apply a small amount of threadlocker to 1 8 NPT Shaft Clamp Access Plug threads Using the 1 4 hex key install the plug and torque to 60 inch pounds DIMENSIONS inch 226 2 8 90 PILOT CAVITY 84 94 3 344 41 63 1 875 CLEARANCE FOR 1 4 20 SHCS 6 ON G100 3 937 BC EQUALLY SPACED ABLE GLAND ENTRY INCREASED SAFETY TOP BTM Application Assistance 1 800 234 8731 847 662 2666 Page 5 SPECIFICATIONS STANDARD OPERATING CHARACTERISTICS Code Incremental Resolution to 2048 PPR pulses revolution See Ordering Information Format Two channel quadrature AB with optional Index Z ungated and complementary outputs Index 180 degrees 18 degrees electrical ungated Phase Sense A leads B for CCW shaft rotation viewing the shaft clamp end of the encoder Quadrature Phasing 1200 PPR 90 15 electrical 2048 PPR 90 30 electrical Symmetry 180 18 electrical Waveforms Squarewave with rise and fall times less than 1 microsecond into a load capacitance of 1000 pf ELECTRICAL Input Voltage 7 15VD
12. e which output driver option to select The configurations below are examples of protected wiring practices and help to determine the best wiring scheme EN Series Encoder Wiring Configuration with Fused Power and LED activity Lights LED Fused Power Terminal Block 200mA max Suggested Typ Standard Terminal Block Acquisition System EN Series Encoder LED Fused Terminal Block No Fuse Installed for Indicator LED Only ejej ejej j e Application Assistance 1 800 234 8731 847 662 2666 Cable Entry amp Gland Selection This product is supplied with dual 3 4 NPT entry holes for wiring to the terminal block SPECIAL CONDITIONS FOR SAFE USE denoted by X in the certificate number require cable entry to be fitted with an ATEX certified Type e cable gland Any gland certified for use as Type e and matching the cable selected and designed to fit a 3 4 NPT can be used If ordered from Dynapar with no gland customer must supply an appropriate gland If ordered with one of our available glands proper manufacturers assembly instructions must be followed Refer to HAWKE assembly instructions included with your product or locate and reference them on the HAWKE website www ehawke com Dynapar Available Glands ref page 6 Ordering Informat
13. ion Code 5 Code 1 Non Armored Cable HAWKE 501 421 A 3 4 NPT S Assembly Instruction A1 307 Issue M 11 08 Code 2 Armored Cable HAWKE 501 453 UNIV A 3 4 NPT Assembly Instruction A1 300 Issue M 11 08 Signal and Wiring WAVEFORMS DATA AND INDEX Not all complements shown A shown for reference 180 aide r e 90 ELEC TLS LITLE Le DataA DataA LJ LT LU LJ Data B sum HL Index P oa A leads B CCW From Clamp End ELECTRICAL CONNECTIONS Encoder Terminal Box Function Connection Sig A 1 Sig A Sig B Sig B Sig Z Sig Z Power V Com Application Assistance 1 800 234 8731 847 662 2666 Wiring Procedure Step 1 Remove terminal box cover Assemble cable amp gland per manufactures instructions Step 2 Strip cable jacket back 3 inches Strip individual leads back 0 35 Step 3 Wire to terminal block using pin assignment on this page or on the inside of terminal box cover Carefully press a 1 8 flat blade screw driver into the inboard hole to open terminal Insert wire completely and remove screwdriver Step 4 Replace terminal box cover Page 3 MECHANICAL INSTALLATION CAUTION Upon initial inspection of the shaft cou STEP 1 Please reference the below diagram titled EN 44 pling area of the EN44 you will notice a 10 32 screw Motor Mount Requirements to ensure that a correct that extends through the encoder body a
14. ion com Application Assistance 1 800 234 8731 847 662 2666 Page 8 pp sira CERTIFICATION SCHEDULE EC TYPE EXAMINATION CERTIFICATE Sira 09ATEX5172X Issue 1 13 DESCRIPTION OF EQUIPMENT The equipment is an optical encoder that is intended to be attached to the rotating shaft of a machine It uses an anodized aluminium enclosure that has three internal compartments A compartment at one end of the equipment contains certified Ex e terminals that are used for external connections external cables enter this compartment via certified Ex e cable glands and any unused entries are blanked by certified Ex e plugs This Ex e compartment is fitted with a lid that allows access to the terminals The compartment at the other end of the encoder contains Ex m devices that include an encapsulated printed circuit board assembly The central compartment houses an optically encoded disc this is fitted to a shaft that emerges from the wall of the compartment The disc is fitted with an optical reading device that is protected by intrinsic safety Ex ia however there are no intrinsically safe inputs or outputs An alternative version of the equipment is fitted with a permanently connected cable This version of the equipment has no Ex e terminal compartment Entry of the cable is again via an Ex e cable gland Supply Input 15 V Version 26 V Version Un 250 V m 250V 15 mA T 50 C to
15. is not compromised Aggressive substances e g acidic liquids or gases that may attack metals or solvents that may affect polymeric materials Suitable precautions e g regular checks as part of routine inspections or establishing from the material s data sheet that it is resistant to specific chemicals Application Assistance 1 800 234 8731 847 662 2666 Temperature ratings The equipment is only certified for use in an ambient temperature range 50 C to 100 C The encoder is rated at IP54 for certification purposes In order to achieve this level of protection appropriate ATEX certified type e Glands or Plugs must be used by the end user The thread form of the cable entries is 3 4 NPT Terminal blocks type e certified for the conductor range Connectable Conductor Cross Section Rigid mm AWG 0 14 2 5 26 14 0 14 2 5 26 14 0 14 1 5 26 16 0 14 2 5 26 16 Flexible mm AWG MAINTENANCE ISSUES Periodic inspections should be made to ensure that there is not excessive play in the encoder shaft due to bearing wear or damage Additional documentation provided with each unit Sira Certificate Installation NonBarrier 200872 0001 PREPARATION Disconnect power from equipment and encoder cable Note Ensure that pipe thread tape or equivalent sealer is applied to the conduit entry stopping plug and mating cable gland for proper sealing Position the anti
16. nce with the appli cable code of practice Care should be taken to inspect the shipping container and product for external damage and or missing parts If any is found contact Dynapar immediately as well as the shipping agent Tools Required for Installation Caliper amp Dial Indicator Gages Shaft Checks 1 4 Hex Key Wrench Shaft Clamp Access Plug 5 32 Ball End Hex Key Wrench Shaft Collar Clamp and Shaft Clamp Alignment Screw Encoder Mounting Screws Stopping Plug Cable Gland Terminal Box Cover Terminal Block Wiring 3 16 Hex Key Wrench 10mm Hex Key Wrench Open End Adjustable Wrench 7 64 Hex Key Wrench 1 8 Flat Blade Screwdriver Torque Wrench 20 75 inch pound range Tightening Fasteners Threadlocker Loctite 242 or equivalent Retaining Fasteners Application Assistance 1 800 234 8731 847 662 2666 Application Environment The EN44 is uniquely designed with the primary protec tion technique as Encapsulation The encapsulated electronics and increased safety interface allow for use in Zones 1 and 2 with flammable gases and vapors with apparatus groups IIA IIB amp IIC and with temperature classes T1 T2 T3 and T4 The equipment is only certified for use in ambient tempera tures in the range 50 C to 100 C Compliance with the Essential Health and Safety Re quirements has been assured by compliance with the following documents EN 60079 0 2006 General IEC 60079 0 2007 General EN
17. nd into the mounting interface is provided for the mechanical installa shaft coupling tion of this encoder The EN44 has a 0 110 inch piloted face that is concentric with the Flex Coupling Be sure to create a DO NOT remove this Coupling Locating Screw until concentric pilot with the six 1 4 20 inch threaded holes on directed to do so in Step 9 of the Installation Proce customer equipment as shown in the diagram dure STEP 2 Ensure the mounting interface and shaft extension are Please familiarize yourself with the following as seen free of dirt grease or any other foreign matter Check the in the magnified view drawing below shaft Total Indicated Run out TIR and ensure that it does not exceed 0 005 TIR STEP 3 Using the 1 4 hex key remove the Shaft Clamp Access Plug from the side of the encoder body 3 Flex Coupling Locating Screw STEP 4 Place the 5 32 ball end hex key into the access hole 4 Coupling Locating Hole and loosen the Shaft Collar Clamp Screw Place a small 1 Shaft Clamp Screw 2 Shaft Clamp Access Plug amount of threadlocker on the screw threads and re install it Note The encoder can be mounted on shafts of varying he Cl Coll Rethroselalt into the cl lengths MIN 0 47 in MAX 0 83 in into the Clamp Collar Re thread the screw into the clamp loosely DO NOT TIGHTEN Remove the 5 32 ball end hex EN44 MOTOR MOUNT REQUIREMENTS key from the access hole 005 STEP 5 Place a Lockwasher onto each
18. o the design and construction of equipment intended for use in potentially explosive atmospheres given in Annex II to the Directive The examination and test results are recorded in the confidential reports listed in Section 14 2 9 Compliance with the Essential Health and Safety Requirements with the exception of those listed in the schedule to this certificate has been assured by compliance with the following documents EN 60079 0 2006 EN 60079 11 2007 IEC 60079 0 2007 used for guidance in respect of marking EN 60079 18 2004 EN 60079 7 2007 10 If the sign X is placed after the certificate number it indicates that the equipment is subject to special conditions for safe use specified in the schedule to this certificate 1 This EC type examination certificate relates only to the design and construction of the specified equipment If applicable further requirements of this Directive apply to the manufacture and supply of this equipment 12 The marking of the equipment shall include the following amp ll 2G Ex ia mb e IIC T4 Gb Ta 50 C to 100 C Project Number 20998 C Ellaby a C Index 13 Certification Officer This certificate and its schedules may only be reproduced in its entirety and without change Sira Certification Service Rake Lane Eccleston Chester CH4 9JN England Page 1 of 3 Form 9400 Issue 1 Tel 44 0 1244 670900 Fax 44 0 1244 681330 Email info siracertification com Web www siracertificat
19. ollow the guidelines for a type e Increased Safety Installation Other cable considerations include flammability temperature chemical etc as applies to the area and environment of installation If in doubt see the IEC EN60079 14 standard as applies to Increased Safety installations and local regulations Important Wiring Instructions Use shielded cable with a defined wire gauge per the following table Terminal blocks type e certified for the conductor range Connectable Conductor Cross Section Rigid Soild Wire mm AWG Flexible Stranded Wire mm AWG 0 14 2 5 26 14 0 14 1 5 26 16 Consider the length of cable and desired drive currents for your application Consider a 0 5mm or 20AWG cable as a minimum starting point You can increase or decrease the wire diameter based on your specific application SHIELDING It is good wiring practice for a shield to be connected to signal ground at the receiving device only Connecting the shield at both ends can cause grounding loops problems that degrade system performance and give a path for stray currents to travel EN Series Encoder Wiring Configuration with Fused Power LED Fused Power Terminal Block 200mA max Suggested Typ Standard Terminal Block Acquisition System A EN Series Encoder B B Z Z
20. rotation arm at a 90 degree angle Ideal to the motor shaft This orientation ensures Minimal housing rotation and encoder error caused by relative motion Reduced misalignment of bearing rod ends to prevent binding and premature wear due to high degrees of misalignment Do not disrupt the anti rotation arm s 90 alignment with the motor shaft during mounting A parallel orientation between the anti rotation arm and the motor shaft is not recommended because it will significantly reduce the anti rotation arm s performance and operational lifetime Each rod end can withstand only 50 of deviation Ideally the anti rotation arm should be mounted with rod end ball centered in its socket Recommended torque 20 FT LBS 27 N m Page 7 sira CERTIFICATION 1 EC TYPE EXAMINATION CERTIFICATE 2 Equipment intended for use in Potentially Explosive Atmospheres Directive 94 9 EC 3 Certificate Number Sira O9ATEX5172X Issue 1 4 Equipment Optical Encoder 5 Applicant Dynapar Corporation 6 Address 1675 Delany Road Gurnee Illinols 60031 1282 USA 7 This equipment and any acceptable variation thereto is specified in the schedule to this certificate and the documents therein referred to 8 Sira Certification Service notified body number 0518 in accordance with Article 9 of Directive 94 9 EC of 23 March 1994 certifies that this equipment has been found to comply with the Essential Health and Safety Requirements relating t
21. talled The terminals shall only be fitted with wires that have cross sectional area falling within the following limitations Rigid 0 14 to 2 5 mm 26 to 14 AWG Flexible 0 14 to 1 5 mm 26 to 16 AWG The equipment shall be supplied from a power supply that has an output that is isolated from earth ESSENTIAL HEALTH AND SAFETY REQUIREMENTS OF ANNEX II EHSRs The relevant EHSRs that are not addressed by the standards listed in this certificate have been identified and individually assessed in the reports listed in Section 14 2 CONDITIONS OF CERTIFICATION The use of this certificate is subject to the Regulations Applicable to Holders of Sira Certificates Holders of EC type examination certificates are required to comply with the production control requirements defined in Article 8 of directive 94 9 EC All complete manufactured units shall be subjected to a routine 500 V r m s a c between all terminals and the equipment enclosure in accordance with Clause 10 3 of EN 60079 11 2007 All manufactured units shall be subjected to a visual inspection on the encapsulation No damage shall be evident such as cracks in the compound exposure of the encapsulated parts flaking inadmissible shrinkage swelling decomposition failure in adhesion or softening This certificate and its schedules may only be reproduced in its entirety and without change Sira Certification Service Rake Lane Eccleston Chester CH4 9JN England Tel 44 0
Download Pdf Manuals
Related Search
Related Contents
CUIDADO - Dow AgroSciences eco タッチリモコン RC-DX1 ユーティリティソフト 取扱説明書 Samsung DVD-P247A Manuel de l'utilisateur Télécharger le fichier Dinplac - LLadopol Patriot Memory PCNASGB-W print server SYBA CL-KVM-281 KVM switch DEH-1730R DEH-1700R - Pioneer Europe Sharp CE-150 Service manual - Printer and Cassette - PC Copyright © All rights reserved.