Home
CPS1200EILCD/CPS2200EILCD User's Manual
Contents
1. snd x 2 Ventilation The location should provide adequate air flow around the INVERTER with 10 CM minimum clearance on all sides for proper ventilation CPS1200EILCD CPS2200EILCD sc iki aiacahad User s Manual Connect the external battery with the DC cables sers Manua from the back of the INVERTER Follow battery K01 C000012 00 polarity guide located near battery cables as below IMPORTANT SAFETY INFORMATION Red cable for battery positive polarity SAVE THESE INSTRUCTIONS Black cable for battery negative polarity This manual contains important safety instructions Please read and follow all instructions carefully 4 Connect to AC and Charge the Battery during installation and operation of the unit Read this manual thoroughly before attempting to unpack Connect the INVERTER to a wall outlet Avoid using extension cords and adapter plugs Charging install or operate the INVERTER the battery for at least 8 hours is recommended to insure that the battery is fully charged To Insure the wall outlet and INVERTER are located near the equipment being attached for proper recharge the battery simply leave the unit plugged into a wall outlet To maintain optimal battery accessibility charge leave the INVERTER plugged into an AC outlet at all times To reduce risk of damage and injury please use batteries with good quality This INVERTER can be charged even when INVERTER is not turned on Provide adequate v
2. KW the motor of 800W AIR COOLER having risk of rebooting and so on In this mode the INVERTER operating voltage in AC mode is within 190 260Vac with the same output voltage The line sensitivity is higher B Select Wide setting to save energy In this mode the operating range of voltage for the INVERTER is 100 280Vac Therefore the output voltage will be the same as the MAINS input voltage The INVERTER unit in this mode has a lower sensitivity with a longer transfer time for switching from AC mode to battery mode in the event of power failure You can safely connect and use home appliances which are not sensitive to transfer time limitations such as florescent tubes bulbs TV etc o AC outlet The INVERTER provides one outlet for connected equipment to insure temporary uninterrupted operation during a power failure and against surges and spikes Note 6 outlet types available including Universal Schuko French UK India and NEMA type AC Inlet Connect to utility power through the input power cord Functional Test AC Mode The INVERTER delivers power to the load derived from the utility and maintains proper battery charge On Battery Mode The INVERTER operates on battery when the utility voltage has fallen outside the limits Local users are alerted to this mode of operation by visual and audible indicators The INVERTER provides power to the load from the battery and the output voltage of the INVERTER are re
3. ap Cap Voltage Voltage of Load Lox a OT eS TT Se Ss LOAD BATT CAP Q tim IK aX INVERTER Status Display pv xX x Line mode Select SW Press 2nd V Overload V Illuminated XK Not Illuminated _ Either Battery mode INVERTER Status Display Sr V V V V X V v EA vE X Not Illuminated Capacity Display Digital Value Display T Load Battery Input Output ae Cap Cap Voltage Voltage of Load Px ft ve ft ov tT eae a ee ee E Select SW Press d X and X CV Sound Disable Press gt 3sec g again X Sound Enable Overload y Illuminated Either Off charging mode Auto bypass INVERTER Status Capacitv Displa Display iii Select SW Digital Value Display Press i Load Battery Input Output y Illuminated X Not Illuminated Either Visit www cpsww com for more product information and the nearest CyberPower local contact for your region Entire contents copyright 2012 CyberPower Systems Inc All rights reserved Reproduction in whole or in part without permission is prohibited x
4. entilation for the battery compartment The battery enclosure should be designed to prevent accumulation and concentration of hydrogen gas at the top of the compartment 5 Connect the Load DO NOT expose the INVERTER to rain snow or liquids of any type The INVERTER is designed for Connect the equipment to the La ak outlet Please make sure that the total loads of your equipments are less than the maximum total power load of the INVERTER indoor use only DO NOT obstruct the ventilation openings DO NOT connect neutral of the power distribution box on the wall to BASIC OPERATION a The OUTPUT neutral of inverter FRONT PANEL DESCRIPTION or b The INPUT neutral of equipment Otherwise the reversed polarity will damage the inverter and the connected equipment Common Neutral T Utility power CAUTION Risk of electric shock do not remove cover No user serviceable parts inside The battery can energize hazardous live parts inside even when the AC input power is disconnected High resolution and intelligent LCD display shows all the INVERTER information with icons and To avoid electrical shock turn off the INVERTER and unplug it from the AC power source before messages For more information please check the Definitions for Illuminated LCD Indicators servicing the battery Servicing the battery can only be performed by trained personnel section 1 LCD Module Display N Power Switch Press the power switch to t
5. fective Verify that the load Overload matches the capability specified in the specs oo Remove some non critical Backup time is shortened Overload load 2 Reset the input protector Alarm buzzer beeps continuously Charge battery for 8 hours or more Battery voltage is too low If any abnormal situations occur that are not listed above please contact service personnel TECHNICAL SPECIFICATIONS CPS1200EILCD 1200VA 720W CPS2200EILCD 2200VA 1320W Capacity VA Capacity Watts Wide mode 100VAC 280VAC Narrow mode 190VAC 260VAC 50 60Hz Input Voltage Range Frequency Range On Battery Output Voltage On Battery Output Frequency Overload Protection Physical Total of INVERTER Receptacles Maximum Dimensions Weight Battery Lead Acid Battery Warning Diagnostics Indicators Audible Alarms Environmental Simulated Sine Wave at 220Vac 10 50 60Hz On Utility Circuit Breaker On Battery Internal Current Limiting 1 Shuko FR UK India NEMA UN 265mm L 250cm W 90cm H 2 05 kg 4 5 Lbs 2 2 kg 4 9 Lbs 12V 24V INVERTER Status Display Low Battery Overload Fault Operating Temperature Operating Relative Humidity Management Auto Charger Auto Restart DEFINITIONS FOR ILLUMINATED LCD INDICATORS LCD Indication 32 F to 104 F 0 C to 40 C 0 to 90 NON CONDENSING ot m 00 Capacity Display Digital Value Display 2X Load Battery Input Output C
6. gulated within a narrow range 1 Switch On Press the power switch then the status LCD will light up 2 Switch Off Press again the power switch the status LCD will go off 3 Cold Start Start on Battery This INVERTER can be turned on even when AC is not present Press the power switch then the status LCD will light up ROUTINE MAINTENANCE AND STORAGE ROUTINE MAINTENANCE 1 Use dry soft clothes to clean the panel and plastic parts Do not use any detergent that contains alcoholic ingredient 2 Unplug the INVERTER from power inlet if the INVERTER will not operate for long period of time STORAGE 1 First turn off your INVERTER and disconnect its power cord from the wall outlet Disconnect all cables connected the INVERTER to avoid battery drain 2 The INVERTER should be stored in a cool dry location 3 Make sure the battery is fully charged before the INVERTER is stored 4 For extended storage in moderate climates the battery should be charged for 12 hours every 3 months by plugging the power cord into the wall receptacle and turning on the main switch Repeat it every 2 months in high temperature locations TROUBLE SHOOTING Remedy 1 Battery Weak 1 Re charge battery No LCD display 2 Battery defective 2 Battery replacement 3 Power switch is not 3 Press and hold power pressed switch 1 AC Input missing 1 Check AC input Mains normal but not connection works in AC mode l l 2 Input protector is ef
7. on the battery powered outlets should not exceed 80 of the unit s capacity IN NEMA 6 outlet types available including Universal Schuko French UK India and NEMA type 1 DC Input Cable Black HARDWARE INSTALLATION GUIDE Connect to battery negative polarity Before installation please read and understand the following instructions 2 DC Input Cable Red Connect to battery positive polarity 1 Placement The Inverter must be installed in a protected environment away from heat emitting appliances such as a radiator or heat register Do not install this product where excessive moisture is present 3 Input Circuit Breaker The circuit breaker provides optimal overload protection e Charger Control A Select Default setting for general application The charge voltage is 13 7V 27 4V respectively for CPS1200EI and CPS2200EI B Select Customized setting for special battery condition The charge voltage is 13 3V 26 6V respectively for CPS1200EI and CPS2200EI Note Operate by trained professionals ONLY Incorrect operation will damage the battery vl Input Voltage Range Selector Input voltage range is defined in specification section Output voltage is the same as input voltage in AC mode A Select Narrow setting for general electrical appliance such as TUBE LIGHT ENERGY SAVING LAMP TV JUICER amp MIXER etc It is not suitable for high power motor or inductive load such as the fridge of 1
8. urn the INVERTER ON or OFF INSTALLING YOUR INVERTER SYSTEM UNPACKING 3 LCD Function Selected Switch Inspect the unit upon receipt The box should contain the following The switch can be used to select the LCD display contents including input output voltage and load Inverter Unit x 1 Power Cord x 1 User Manual x 1 percentage etc HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT PEAR PANEL DESCRIPTION 1 Insure that the equipment plugged into the AC outlet does not exceed the INVERTER unit s rated capacity 1200VA 720W for CPS1200EILCD 2200VA 1320W for CPS2200EILCD If rated unit Capacities are exceeded an overload condition may occur and cause the INVERTER unit to shut down or the circuit breaker trip 2 If the power requirements of your equipment are listed in units other than Volt Amps VA convert Watts W or Amps A into VA by doing the calculations below Note The below equation only calculates the maximum amount of VA that the equipment can use not what is typically used by the equipment at any one time Users should expect usage requirements to be approximately 60 of below value CF TO ESTIMATE POWER REQUIREMENTS K E 1 220 Vx Amps A VA 1 UN FR UK 2 Add the totals up for all pieces of equipment and multiply this total by 0 6 to calculate actual requirements There are many factors that can affect the amount of power that your computer system will require The total load that you will be placing
Download Pdf Manuals
Related Search
Related Contents
Epare EPSPM001 Use and Care Manual TCA SERIES WARNING Les marchés de la Rmn-‐GP - Réunion des musées nationaux Mounting & Sighting-In Ballistic LaserScope™ User's Guide 1001587-3FR-05 PSEN b3, PSEN b4, PSEN b4.1 SENSAI - Tokyoflash macLEDS SNAP-flat-LO-19.5-W-24WAC Installation Guide Hampton Bay 299440 Instructions / Assembly DataVideo PD-1 power distribution unit PDU Copyright © All rights reserved.
Failed to retrieve file