1. Theme Parks e Architectural Lighting Typical Application The XSH xxR works within DMX RDM environments as well as in pure DMX environments Therefore the XSH xxR is a good solution for those who expect to use RDM in the future The XSH xxD on the other hand only works with DMX while it ignores any RDM data Unpacking The XSH Hybrid Splitter is packaged in a cardboard box The following items are included e The device e This user manual 75 7550 1 Rack mounting kit 2 brackets and 8 screws with XSH xRx versions only Safety Information Consider the following notes absolutely when you set up connect and use the XSH This product is not for household use Read this manual before operating the device follow the safety precautions and observe all warnings in this manual Use this device only in accordance with local laws and regulations Safety Precautions Disconnect the device from AC power before removing any cover or part including any fuse and when not in use Ensure that the device is electrically connected to ground earth Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault protection Before using the device check that the power distribution equipment and cables are in perfect condition and rated for the current required of all connected devices Isolate the
2. A blue Neutrik powerCon NAC3FCA cable mount connector must be used to supply power at the XSH hybrid splitter power input socket Warning For protection from dangerous electric shock the device must be grounded earthed The local AC power source must have both overload and ground fault earth fault protection Important Only insert or remove a live Neutrik powerCon connector to apply or cut power in an emergency as doing so may cause arcing at the terminals that will damage the connectors Power Outlets Warning The total current load of all devices connected to AC mains power outlets of the XSH hybrid splitter power must not exceed 19 8 amps A power cable that meets the requirements specified on safety instructions of this manual must be used to connect the XSH Hybrid Splitter to AC mains power and to connect other devices to the power outlets A light grey Neutrik powerCon cable mount connector must be used to draw AC mains power from the XSH Hybrid Splitter s power outlets No matter what the AC mains power voltage 15 the current draw of all the devices that draw AC mains power from the power outlets of an XHS hybrid splitter must not exceed a total of 19 8 amps DMX Connections Depending on the version the XSH is equipped with 5 pin or 3 pin XLRs 5 7550 Pin Connection m 1 GND 2 Data 10 95 o_o 3 Data ee 9 gt 4 Not co
3. device from power immediately if the power cable or the power plug is in any way damaged defective or wet or if they show signs of overheating Do not expose the device to rain or moisture Do not operate the device if any cover or component is missing damaged or deformed Refer any service operation not described is this manual to Swisson Provide unrestricted airflow around the device Do not operate the device if the ambient temperature exceeds 55 C 131 F Do not modify the device in any way not described in this manual or install other than genuine Swisson parts Do not attempt to bypass any fuse Replace any defective fuse with one of the specified type and rating only When suspending the device ensure that the supporting structure and all hardware used can hold at least 10 times the weight of all devices suspended from them When suspending the device install a secondary attachment such as a safety cable that is approved by an official body such as T V as a safety attachment for the total weight it secures The safety cable must comply with EN 60598 2 17 Section 17 6 6 and be capable of bearing a static suspended load 10 times the weight of the device Make sure that any external cover and rigging hardware is securely fastened Block access below the work area whenever installing servicing or moving an overhead device 75 7550 1 Do not use the device in areas where it is exposed to direct sunlight Device O
4. 10 13 20 XSH 3RD 1P4 Hybrid Splitter with rack mounting kit 3 Pin XLR DMX 10 13 21 XSH 5RD 1P4 Hybrid Splitter with rack mounting kit 3 Pin XLR DMX 512 plus RDM Versions 10 13 50 XSH 3BR 1P4 Hybrid Splitter box 3 Pin XLR DMX amp RDM 101351 XSH 5BR 1P4 Hybrid Splitter box 5 Pin XLR DMX amp RDM 10 13 60 XSH 3RR 1P4 Hybrid Splitter with rack mounting kit 3 Pin XLR DMX amp RDM 10 13 61 XSH 5RR 1P4 Hybrid Splitter with rack mounting kit 5 Pin XLR DMX amp RDM Accessories 10 90 75 XAC RACKM XSH Rack mounting kit for Hybrid Splitter 11
5. SH xxR itself is a responder to RDM messages and can be discovered RDM network 19 inch Rack Mounting Option To mount in a rack Fasten the L brackets using the included thread forming Torx 10 M3 x 8 screws as shown above Note XSH xBx models are shipped without L brackets and screws XSH xRx models are shipped with L brackets and screws The rack mounting kit L brackets and screws can also be ordered separately Warning Do not use screws with a thread length of more than 8 mm 0 32 in for mounting the brackets onto the XSH Swisson Technical Data 155mm 133 5 A EE rennen 133 5 mm 5 3 in WEN ee E 302 11 9 auskennen 44 4 1 7 a 1 4 3 Ib Ambient temperature 30 C 55 C 22 F 137 F 100 240 V nominal 50 60 Hz Power supply unit Switch mode auto sensing Typical power consumption uueseeseenssenenennennnnnnnnennenennnnnnnnnnenennn AW DIM Xs sce EEE EE TE E E ANSI E1 11 RDM asua eier ee ANSI E1 20 Electrical standard signal EIA 485 10 ru Ordering Information DMX 512 Versions 10 13 10 XSH 3BD 1P4 Hybrid Splitter box 3 Pin XLR DMX 10 13 11 XSH 5BD 1P4 Hybrid Splitter box 5 Pin XLR DMX
6. XSH Hybrid Splitter Booster User Manual 5 vv7SSON 5 Index ae 3 Maige 4 Unpacking errereen a 4 Safety Information sure 5 Device ee ee inne nee 6 2 vents cen cued senayahgasderscstsausuedessadhesdeeuetegeutoregeveetosi nee RESU R EAE TEIR 8 RDM Protocol Remote Device Management c ccccccccssssscecssssececsssesecseeaececsesaececseaaaeeecseaaeceesesaeceeseaeeeesesaeeeeseaueeecesaas 8 19 inch 2 eu an RL ae hut 9 MECH Dat ales 10 Ordering Informations ne ri 11 SvvissOn Introduction The XSH Hybrid Splitter is a combination of a DMX splitter and a power distribution unit It may dramatically simplify the installation especially when powerCon amp DMX hybrid cables are used While the XSH xxD models spilt and boost only DMX signals the XSH xxR models also detect RDM data and use the protocol s bidirectional functionality to report data back to the controller Lighting board All output ports of the XSH are optically isolated A strong power supply allows a reliable operation in a wide voltage range The XSH is available with 3 pin or 5 pin XLR connectors Applications e Concert Lighting Live Events e Multimedia Shows e Theater 6TV Sets
7. nnected 5 XLR male 5 XLR female 3 Pin XLR male 3 Pin XLR female 5 Not connected DMX in DMX out DMX in DMX out The DMX input is fully isolated and has a built in termination All outputs are isolated transmitters with a bias network for RDM operation Each output port is individually optically isolated meaning that it is totally isolated from the other output ports and from the input section Current Measurement m 20 15 15 11 12 10 8 5 No Curent Power measurement supply Power out Power out Power out Power out The bar graph LEDs show the total amps drawn by and through the XSH The lighting down arrow led shows that the load is less than six amps if all other LEDs are turned off The lighting up arrow shows that the load exceeds 20A This is an overload condition Never run an installation in this condition The current sensor value is also reported over RDM XSH xxR models only Note The LED bar graph is also used to show the RDM identify See RDM Protocol Remote Device Management RDM Protocol Remote Device Management All XSH xxR models support the RDM protocol The RDM protocol is not supported on XSH xxD models The XSH xxR forward the RDM messages to all connected devices and send the RDM responses back to the RDM controller The XSH xxR acts as a non proxy inline device The X
8. verview 5 wi sson Mains Power Input See chapter Mains Connection on page 7 for more details 1 2 Do Power LED The Power LED shows ifthe device powered and if power supply unit of the XSH is working DMX input Signal LED A green LED shows if a signal is available at the input port Ared LED shows if received signal is faulty Amp display The bar graph LED shows the total amps drawn though the XSH Power outlets DMX outputs Eye for safety wire M10 amp M12 female thread for clamp 5 5 XSH Block Diagram XSH xxD models XSH xxR models Control Logic Control Logic t t t t t 65 65 65 A Optical Optical Optical Optical Teanceiver Isolation Isolation Isolation Isolation t t t t t VAI VAIVAI VA Line Termination Termination Tranceiver Tranceiver Tranceiver t t t t t Connection The user must supply a suitable power cable The user must then either hard wire the power cable to the building s electrical installation providing an easily accessible power on off switch close to the device or install on the power cable a grounding type earthed mains plug that is suitable for the local power outlets following the power plug manufacturer s instructions Consult a qualified electrician if you have any doubts about proper installation
Download Pdf Manuals
Related Search
Related Contents
User Manual Rectificadors-carregadors, Gamma MIT NG 968A aoyue ® Pressurized enclosure system Books, Software, Associations, Automotive, Locks, Safes, Manuals QNAP VS-8124U-RP PRO+ Epicureanist Dual-zone VT-12TEDS-2Z 12-bottle Thermoelectric Wine Cooler - VT-12TEDS Brochure - John Blair Honda USER MANUAL Cosmos-Alkoholtester GmbH Copyright © All rights reserved.