Home
Service Date Interface Unit user guide Jan 2010 issue 2
Contents
1. issue 2 ase 61 7 fee wf a POP Y TECHNOLOGY a Service Date Interface Unit user guide Jan 2010 issue 2 Data Exchange with a PC Not yet available Turning off the SDIU To Turn off your SDIU simply return to the Link Menu press F2 then Press and hold the F1 button for 3 seconds There will be a short single audio tone and the mains display and green power Led will go off Do not leave the SDIU in Power save mode when not in use as this will greatly reduce the life of the internal batteries Batteries The SDIU is power by two type AA 1 5 v Alkaline batteries Depending on the length of time the SDIU is turned on for should provide at least twelve months of average daily usage It is not recommended to use rechargeable batteries as they will changing more often and the SDIU set up data will need to be reset each time the batteries are changed The Batteries are accessed via the battery compartment cover on the rear of the SDIU there is no need to open the main SDIU case It is recommended that Batteries should be inspected once a year to ensure that no leakage or corrosion has occurred If there any signs or this occurring both batteries should be replaced immediately after cleaning the battery terminals Alkaline batteries should be disposed of in accordance with your local environmental waste policies amp procedures SDIU maintenance amp Technical support General Maintenance Software updates Techn
2. controlled special to type test equipment designed to reduce equipment down time and increase service efficiency by helping the field or hospital service engineer maintain amp repair any of the range of Linet Active Pressure relieving mattresses The SDIU has a strong ABS equipment casing that is designed to survive in the engineers tool kit and workshop or field repair environments The Infra red data link provides easy reliable instant connection to any of the Ilnet range of SCUs without the need to open the Pump or additional external cables The SDIU can be used to simply check the Production details of the SCU or review and update the Fault and service data thus providing the service engineer with e Alive service history of the unit without the need to contact head office for service records e Aninstant log of any faults that the unit has experienced and when they occurred The powerful Repair Display amp Mattress test modes allow at the touch of a button all product functions and SCU components to be tested without opening the SCU case Also greatly reducing the time taken for fault diagnosis and eliminating time wasted trying to repair by component substitution If required for your service organisation the Data Exchange facility SCU repair amp test information can be stored and downloaded to a PC on return to base thus reducing the need for and time taken writing or typing in service details The SDIU s own firmware can e
3. Display mode screen will show the status of all indicators on the SCU front panel Mode Alternating Static Evaluation F6 can be used to toggle the backrest indicator on off Use gt lt keys to change F6 option to Use Por J keys on navigation pad to return to Display mode top level Menu or move down to next level The second Display mode screen will show the performance of the rotor valve Run time operating hours since manufacture Last home number of steps since home position was last passed Back lash number of steps lost when rotor moves backwards Use Tor J keys on navigation pad to return to Display mode top level Menu or move down to next level Page 12 of 16 issue 2 050 TECHNOLOGY Service Date Interface Unit user guide Jan 2010 Mattress Test Mode Display Readings Record readings issue 2 Display will give the option to display or record mattress pressure readings Select F2 Display will show current mattress pressure readings in mmHG Press F1 to end test amp return to first menu screen Display will give the option to display or record mattress pressure readings Select F3 Display will give option to set recording time using F4 5 Press V to start test Display will show pressure readings and time left to run test At end of test display will show test complete Press F1 to exit test amp return to Mattress test top level menu 959 de TECHNOLOGY e
4. POP Y ve TECHNOLOGY e Service Date Interface Unit user guide Jan 2010 issue 2 Contents Service Data Interface Unit SDIU DescriptioN ooooconcccccnononnnnnnonncnnononnnnnnnnnnnnnnnnonnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnne nn nnnanannnnnnns 2 General Oper a ads 2 SDIU Layout amp Keypad FUNCTIONS ei coonioicaicn cidcid cidad cadencia ada iaa added and 4 Turn OA amp link tO SCU a AA A A A a 5 POWEerSaVe Modern raro isis raid 6 Productionidata MOQ Escortin eioi a TI O A o aiii 6 View Production data iii ais 6 Edit ProductioniD td rita torcida 7 Send Production datas cisci ite a di a aa ie 7 Service Data Moderno ias 8 EnNtering Servicesdatal ista icono vds 8 Repair Mode sevi a 1 Display ModE ia a rai ooo 11 Mattress Test Modena a Att 1 Fadl LOS Mode aiii AA A A O 14 SDIWISEU UD MIO oi iio aan 14 Battery Mode cui a 15 Data Exchange With a PG sss scecexccescesscccececscescedesdihasean teagees checseacobaseonteene le cavaunnssadebeseen a aa fs adebapaas RA a 16 AAA O 16 Battle A At 16 SDIU maintenance amp Technical support cccccccesssssssecececessessseceeccececscsaaaecesecesesaesaaaaecesecuseesesaesecescsusesaaaeeeeeessseseneeeeess 16 General Maldten Mccain 16 SoftWare Updates cid OA DIRA A EA Adi 16 Ta dada EE 16 Page 1 of 16 POD Y TECHNOLOGY ea Service Date Interface Unit user guide Jan 2010 issue 2 Service Data Interface Unit SDIU Description The SDIU is a sophisticated state of the art microprocessor
5. a Service Date Interface Unit user guide Jan 2010 issue 2 Fault Log Mode Display will show fault log entries Entry number Run time when fault occurred Fault Code If applicable which cell s caused the fault Use gt lt keys to scroll through log entries Use Por J keys on navigation pad to return to Fault log top level Menu SDIU set up Mode This is the only mode that will be available if the SDIU is not linked to an SCU This mode is used to set the service engineers code SDIU time amp date Display will show Back light setting Use F4 F5 to set level from range Off 1 20 Full note use minimum level necessary to save battery power Use J keys on navigation pad to to move onto next screen Page 14 of 16 050 TECHNOLOGY Jan 2010 Battery Mode Not yet available Service Date Interface Unit user guide Display will show time amp date menu Use Pu gt keys on navigation pad to select digit to change Use F4 F5 to change digit note after replacing battery change year using F5 to 2099 then F4 to select 2009 Use J keys on navigation pad to move onto next screen Press v to Select first service engineer code digit Use F4 F5 to change value Use J keys on navigation pad to move onto next screen Press V to select language field Use F4 F5 to language type Press v to confirm selection Use Tor J keys on navigation pad to return to Fault log top level Menu Page 15 of 16
6. asily be updated to take enable it to be used with any new Linet models or updates to current model SCUs this allowing the SDIU to keep pace with the product range and being a service engineers tool for life General Operation If using the SDIU for the first time or after changing the batteries the SDIU data will need to be set up see relevant section of this manual The SDIU I R link is very reliable and can operate a long distances from the SCU it is however recommended to ho d the SDIU approximately level with the SCU I R window and at no more than 0 5Mtr form the SCU so that the SCU display panel can be seen and its mode of operation monitored If communication to the SCU is lost for any reason the SDIU will always try to automatically recover the link If communication cannot be automatically re established you will need to return to the Link menu and press F2 If there is no SCU in range or the SCU has no mains power connected or is not turned on the display will show Page 2 of 16 250 TECHNOLOGY Service Date Interface Unit user guide Jan 2010 and only the SDIU set up mode will be available Page 3 of 16 issue 2 050 TECHNOLOGY Jan 2010 SDIU Layout amp Keypad functions LCD display with back light Displays SDIU amp SCU status amp data Green power light Illuminated when SDIU is live flashing when SDIU in power save mode F1 Go button Press amp hold for 3 seconds to turn SDIU on or
7. guide Reset Service Indicator Repair Mode Press F4 on Service data Display will show ask you to confirm reset action Press F1 to confirm Display will then indicate if the Service indicator has been reset Use Tor keys on navigation pad to return to Service data Menu Display will show Status of push buttons of front panel O off on This can be used to test each button Order of indictors is GO Mode Mute Press each button in turn to test Display will then indicate if the Service Page 10 of 16 issue 2 O50 TECHNOLOGY Jan 2010 Service Date Interface Unit user guide Display will show if the mattress is connected and the type of mattress Virtuoso Virtuoso 2 or Precioso Display will show the backrest position lowered or raised Use J to move onto the next screen or for key on navigation pad to return to Repair Mode top level Display will show Compressor on or off use F1 to switch state Rotary valve position Use v key on navigation pad to select amp Use gt lt keys scroll through positions Display will show Led test Select the number of the LED to be tested using F4 amp F5 Use F6 to turn LED off on issue 2 LED numbers are Pressure adjust indicator 1 5 mode 6 static 7 Evaluation 8 Battery 9 Backrest 10 Seat 11 Service 12 CPR 13 Fault 14 Page 11 of 16 O50 TECHNOLOGY Jan 2010 Display Mode Service Date Interface Unit user guide The first
8. ical support Page 16 of 16
9. no data Provided that it is not moved out of range of the SCU the I R link will be maintained and the selected SDIU operating mode will continue to function To exit power save mode and return to full display operation simply give the F1 button one short press Production data Mode This mode allows the operator to read amp Edit the production data that has been loaded during the manufacture of the SCU This data is made up of 112 characters the first 11 being the SCU Serial number The data edit function is provided so that the service engineer can load the correct SCU production data into an SCU if the main control circuit board has to be replaced View Production data Display will show Production data menu Press F1 2 as required Press F1 Display will show 112 production data characters First 11 characters are SCU serial number rest of content format not vet defined Use Tor y keys on navigation pad to return to Production data Menu Page 6 of 16 050 TECHNOLOGY Service Date Interface Unit user guide Jan 2010 Edit Production Data Display will show Production data menu Press F1 2 as required Press F2 Display will show 112 production data characters First 11 characters are SCU serial number rest of content format not yet defined defined Use F4 amp F5 keys on navigation pad to select data content amp gt lt to move position Send Production data Press F3 Display will go blank fo
10. off or to exit power save mode F4 amp F5 keys used to select required characters by moving up F4 or down F5 through the available number character or symbol range Service Date Interface Unit user guide issue 2 SDIU Infra Red I R window Must be pointed at SCU I R Window CPR label above Menu Navigation pad Use up Downy left C amp right gt keys to move through on screen menus amp ok V to accept changes Soft function keys F1 F6 key functions defined in on screen menus USB computer connection for data exchange Page 4 of 16 O50 TECHNOLOGY Service Date Interface Unit user guide Jan 2010 Turn on amp link to SCU issue 2 F1 Go button Press amp hold for 3 seconds to turn SDIU an Single audi tone Green power light comes on Display comes on showing Link screen Point SDIUN R window at the IR window on the SCU Press F2 to connect Link screen will show Use gt or lt keys on navigation pad to select required SDIU Mode Use Tor y keys on navigation pad to enter required SDIU Mode menu IO TECHNOLOGY aat Service Date Interface Unit user guide Jan 2010 issue 2 Power Save Mode If no SDIU control button is used for 3 minutes the SDIU will automatically go into power save mode to help conserve battery power In this mode the Green power LED will flash to indicate that Power save mode is active and the mains display will show
11. r a couple of seconds then show data sent ok Use Tor y keys on navigation pad to return to Production data Menu issue 2 RL 07906 wf RS ae 250 des TECHNOLOGY ea Service Date Interface Unit user guide Jan 2010 issue 2 Service Data Mode This mode allows the service engineer to review and update the service data stored in the SCU Display will show Service data menu Press F1 2 4 as required Entering service data Press F1 Display will show Service data Entry menu Today s date SDIU fills this automatically Service engineer code SDIU fills this automatically Service data 10 digits Enter this data using F4 5 amp 6 Run time since manufacture Use for J keys on navigation pad to return to Service data Menu Press F3 to send service data Then F1 or F2 to send or cancel Bottom line of screen will show data send status When Data sent ok Use Tor keys on navigation pad to return to Service data Menu 050 TECHNOLOGY Service Date Interface Unit user guide Jan 2010 issue 2 Reading service data Press F2 on Service data Display will show last service data entry Today s date Service engineer code Service data 10 digits Run time since manufacture Use gt lt keys to scroll through data content move position Use Tor J keys on navigation pad to return to Service data Menu Page 9 of 16 O50 TECHNOLOGY Jan 2010 Service Date Interface Unit user
Download Pdf Manuals
Related Search
Related Contents
MANUALE UTENTE - USER GUIDE - MANUEL Technicolor - Thomson TV/DVD User's Manual EUROLITE EL wire user manual Eastern Bank TreasuryConnect Electronic Report Delivery (ERD PowerTrax Pro End User Manual Tyan Tempest i5100X (S5375) PVCO-2000 Visiophone 7 pouces couleur sans fil 11 07 2013 Copyright © All rights reserved.