Home
AMD RAIDXpert2 User Guide
Contents
1. RAIDXpert2 User Guide 27 Table 13 BIOS Configuration Utility color codes continued Magenta text Indicates items that are related to spares or boot options Red text Indicates a failed virtual or physical disk or a warning For example informational text might be red if an option is not available Initialize Disks New disks and legacy disks must be initialized before they can be used to create an AMD RAID array Initialization writes AMD RAID configuration information metadata to a disk Initialize Disks A CAUTION Ifa disk is part of an AMD RAID array the disk cannot be selected for initialization To initialize the disk anyway delete the AMD RAID array Data on the disk is deleted during initialization so ensure the correct disks are chosen to initialize A CAUTION A legacy disk can contain valid data When a legacy disk is initialized all data on the disk is lost 1 At the Main Menu use the arrow keys to highlight Initialize Disk s 2 Press Enter to select Initialize Disk s 3 Select the disks to initialize e To select all disks press the A key e To select individual disks highlight a disk with the arrow keys and press Insert Any number of disks may be selected using this method 4 Press Enter to initialize the selected disks 5 Press the C key to confirm the initialization Alternatively press Esc to cancel the initialization Initialization takes 10 15 seconds per disk During initi
2. RAID6 Critical One or two disks fail redundant arrays Offline Three or more disks fail RAID10 Critical A single disk fails in any one of the sets RAID levels with multiple redundancies Offline All disks in a set fail Volume and RAIDO Offline A single disk fails 20 Arrays Disks and RAID Levels More than one array can be created using the same set of disks If a disk is disconnected that belongs to more than one array only the arrays that try to access the disk and receive I O errors report the failure For example there are two arrays both of which are RAIDS sets and both use disk 4 If a system being used by array 1 receives an I O error when trying to communicate with disk 4 the state of array 1 changes to Critical However the state of array 2 using disk 4 does not change to Critical until an I O error is reported If systems using array are not communicating with failed disk 4 the state of array 1 still displays as Normal If a rescan of all channels is performed after disconnecting a disk the state of every array using the missing disk changes from Normal to either the Critical or Offline depending on the RAID level See Rescanning Disks for Changes in State on page 23 for a discussion of when to rescan disks and the outcomes when doing so Creating Arrays Future Expansion When creating arrays consider whether disk capacity needs to expand in the future If the file system must
3. Set or change event notifications 1 At the Options menu select Notification The Notification Setup window displays 2 Specify the Outgoing Mail Server SMTP and To Email Address to which e mail messages are sent when an event occurs 3 Ifthe SMTP server requires a login check the Server Required Login box and enter a valid Username and Password for the server 4 Specify a user address as the sender of the e mail notifications in From Email Address By default the system on which RAIDXpert2 is installed is used 5 Click Send Test Message to verify that the e mail notification works i To disable messaging uncheck the Enable Messaging check box in the Notification Events section 7 Choose the types of notification events to use Email or Event Log for each event priority Low Informational Warning Critical Fatal by selecting the appropriate options Ef NOTE Warning Critical and Fatal events will always display in the Event Log Licensing To display Licensing information including available licensing levels select License at the Options menu Add space using a RAIDABLE Array 1 Install a new disk After a rescan a pop up window displays amp NOTE To create a redundant RAID1 array the new disk must be the same size or greater than the RAIDABLE disk 2 Inthe Select a Disk section select the new disk 64 AMD RAIDXpert2 Graphical User Interface GUI 3 In the Choose a Task se
4. Assigning a disk for use as a global spare does not reserve space on that disk An automatic restore is not guaranteed if a disk fails If there is not enough disk space on the global spare make room for the fail over to complete or assign a different disk with enough capacity as the spare If there is enough space available on the global spare and a disk failure occurs the restore process starts automatically For additional information see Add or Remove Global Spares on page 61 24 Arrays Disks and RAID Levels RAID Performance Considerations With RAID technology performance is based on the following considerations e The number and organization of disks in an array e Caching attributes used for the array e Application workload Number and Organization of Disks RAID functions increase performance by putting more disks to work and by buffering data for the host Many disks can transfer data at greater than 50 MB per second RAIDXpert2 can aggregate this bandwidth in an almost linear fashion as more of the same disks are included in an array Caching Attributes RAIDXpert2 can also be configured to provide read and Write Back caching if desired Write Back caching has a large effect on most workloads but should be used with caution Application Workload When configuring an array workload is probably the most important performance variable Most applications do many more reads than writes The best performance is obta
5. Transform Transform an array 1 In the Array View section select the array to transform 2 At the Array menu select Transform NOTE Ifthe system window is not wide enough only the Destination View is displayed Select all the desired disks for the array including disks that might be already in the array by selecting the box next to the drive in the Disk List section NOTE Click Same to select all disks currently used in the array All to select all disks or Unused to select disks that are not currently used in an array Select the RAID level to be transformed at the Array Type drop down menu At the Organized As drop down menu select an option r NOTE The Organized As drop down menu only displays options for advanced management of RAID10 and RAIDS0 configurations if you selected a RAID10 or RAIDS0 Expand the array by entering the size of the new array in the Capacity field RAIDXpert2 User Guide 55 amp NOTE The maximum available capacity changes with e The disks that are selected e The RAID level of the array X TIP For creating volumes larger than 2 TB see Table 31 on page 69 NOTE Ifa Transform is not possible the Commit option is not enabled A typical reason preventing a Transform is insufficient available space on the disks 7 Click Commit 199 Ef NOTE Ifthe system is not licensed for RAIDXpert2 Plus a License Issue message
6. 995 amp NOTE Because the ATA storage industry has standardized the meanings of MB as 1 000 000 bytes and GB as 1 000 000 000 bytes RAIDXpert2 reports the same units Whether the array is hidden from the operating system Globally unique identifier for the array assigned by RAIDXpert2 RAIDXpert2 User Guide 81 Table 42 rcadm Array List elements Element Description Task type Transform Check Check_Bitmap Not_Active Create Restore ff NOTE See Array Tasks Starting and Stopping Tasks on page 22 for detailed definitions Task State The state of the task Started Paused Completed The progress of a current array task such as a Create or Transform shown as percent complete Current array cache setting NC No Cache R Read Cache W Write Back Cache RW Read Write Back Cache Scan Background scan enabled Yes No Name User supplied name for the array Dedicated Spare Indicates the number of dedicated spares assigned to the array verbose mode only Disk Listing of disks that are part of the array Used Capacity used of a specific disk Offset Location on the disk where the array begins View Help from the Command Line To view a list of the major modes of operation Type rcadm helporrcadm To view help for a specific mode and its options Type rcadm lt mode gt helporrcadm lt mode gt For example typing rcadm mana
7. Ef NOTE The maximum available capacity changes with e The disks that are selected e The RAID level of the array X TIP For creating volumes larger than 2 TB see Table 36 on page 71 Select a cache option at the Cache Options drop down menu The default is Read and Write Back Cache RAIDXpert2 User Guide 53 8 9 Check Background Array Scan to enable background array scanning A background array scan checks the sectors of the disks in an array for potential problems A background array scan runs continuously until the user stops it by accessing Array gt Background Array Scan gt Stop X NOTE See Scan an Array in the Background on page 61 for details Check Skip Initialization to skip initialization A CAUTION Creating a redundant array with Skip Initialization selected can result in data corruption 10 Check Leave Existing Data Intact if an array is lost or deleted and the user immediately creates a replacement array of the same characteristics This leaves the data on the disks of the lost or deleted array untouched when the replacement array is created See Table 37 on page 72 for additional information 11 Check Zero Create to write zeros on the created array If Zero Create is used the array is not immediately available the array is hidden from the operating system during the Create process 12 Click Create to create the array Partition and format an array Each operating system
8. it must be initialized before it can be used in a RAIDXpert2 array After a disk is initialized it appears as Disk in the Disk List A CAUTION Do not initialize a disk that is part of an array Initializing a disk in a non redundant array deletes the array and its data The array no longer appears in Array View This is especially true for a non redundant bootable array Initializing a disk in a non redundant bootable array causes the array to Fail and deletes the operating system RAIDXpert2 files and device drivers Initializing a disk in a redundant array causes the array to become Critical Initializing two or more disks in a redundant array deletes the array and its data The array no longer appears in Array View A CAUTION All new disks and legacy disks appear as legacy arrays in the Array View and Array List until they are initialized A CAUTION A legacy disk can contain valid data When a legacy disk is initialized all data on the disk is lost AMD RAIDXpert2 Graphical User Interface GUI To initialize disks 1 At the Disk menu select Initialize The Initialize Disk window displays 2 Select the disk s to be initialized by selecting the box next to the disk s 3 Click Initialize Selected Rescan Disks The Rescan command e Rescans the SATA channels that search for new legacy or removed disks e Rereads the configuration information from each disk When a disk is offline it might be brought onli
9. 36 BIOS Mode 36 UEFI Mode 36 Installing AMD RAID drivers 37 Installing AMD RAID drivers while installing Microsoft Windows 37 Installing AMD RAID drivers while installing Linux 38 Installing the AMD RAIDXpert2 Management Suite for Microsoft Windows 41 Installing the AMD RAIDXpert2 Management Suite for Linux 42 Installing the AMD RAIDXpert2 Graphical User Interface GUI 43 SLED Linux 43 Ubuntu Linux 43 AMD RAIDXpert2 Graphical User Interface GUI 45 Start RAIDXpert2 45 Web browser Access 45 Windows Shortcut Access 45 Password Protection 46 Things to Know About Passwords 46 Change a Password at the Options Menu 46 Help and About Windows 46 Reviewing the RAIDXpert2 GUI 47 The Array View Section of the Array Status Window 47 The Disk List Section of the Array Status Window 47 The Array List Section of the Array Status Window 48 The Event View Section of the Array Status Window 49 Array and Disk Commands 49 Working with Disks 50 Initialize Disks 50 Rescan Disks 51 Change Cache Properties for Disks 51 Assign Spares 51 Legacy Disks 52 Working with Arrays 52 Create and Format Arrays 52 Name Arrays 54 Transform Arrays supported by RAIDXpert2 Plus 54 Restore Rebuild Arrays 56 Prepare to Physically Remove an Array 57 Delete Arrays 57 Change Cache Settings for Arrays 58 Change the Priority Level of a Task 59 Interrupt Cancel or Resume a Task 59 Check for Consistency 59 Schedule a Consistency Check 60 Scan an Array in the Background 6
10. Enter The AMD RAIDXpert2 Management Tool Login is displayed If the Login page does not display verify that you have entered the correct IP address On the Login page enter the name and password of a configured user The default user name and password are admin and admin EE NOTE Both usernames and passwords are case sensitive 3 4 Select a language at the drop down menu Click Submit If the system is available the RAIDXpert2 GUI page is displayed otherwise a message indicates that the system is unavailable Tips for signing in and signing out using a web browser Do not include a leading zero in an IP address For example enter 10 1 4 33 not 10 1 4 033 Multiple users can be signed in to each controller simultaneously For each active RAIDXpert2 session an identifier is stored in the browser Depending on how your browser treats this session identifier you might be able to run multiple independent sessions simultaneously Internet Explorer can run separate RAIDXpert2 sessions if you select File gt New Session If you do not select a new session all instances of Internet Explorer share the same session End a RAIDXpert2 session by selecting Options gt Logout Do not simply close the browser window Windows Shortcut Access Signing in 1 using a Windows shortcut Launch the AMD RAIDXpert2 Management Tool using the Windows shortcut The AMD RAIDXpert2 Management Tool Login is displayed If the Log
11. Number The number assigned to disks in an array Disk Manufacturer The manufacturer of disks in an array The Disk List Section of the Array Status Window Elements of the Disk List Section The Disk List section provides information about all disks assigned or available to arrays Table 16 provides information about the elements of the Disk List section Table 16 Elements of the Disk List section Array Status window Element Description Disk number Disk capacity 1 MB 1 000 000 bytes 1 GB 1 000 000 000 bytes Ey NOTE Because the ATA storage industry has standardized the meanings of MB as 1 000 000 bytes and GB as 1 000 000 000 bytes RAIDXpert2 reports the same units Type SATA and negotiated speed not the speed of the port type Indicates if the disk is assigned as a global spare State of the disk Online Offline SMART Error Type Disk type Disk Legacy New Model Disk manufacturer s model number Serial No Disk manufacturer s serial number Firmware Disk manufacturer s firmware version Space Available Total amount of space unused on the disk RAIDXpert2 User Guide 47 Table 16 Elements of the Disk List section Array Status window continued emer Deseret Largest Available Largest contiguous unused space on the disk Features Information about port communication and physical disk cache settings Ef NOTE Ifa disk is missing f
12. RAIDXpert2 Management Suite for Linux on page 42 Installing the AMD RAID drivers during a Ubuntu 12 x Desktop Linux installation 40 2I NOTE Prior to starting this procedure obtain the AMD RAID drivers from your system supplier or motherboard vendor Copy the AMD RAID drivers to the dd directory on a USB flash drive following the instructions in Copying AMD RAID drivers in a Linux environment on page 35 NOTE The Ubuntu driver CD ROM iso image contains all Linux variations for a particular release NOTE Some of the windows indicated in this procedure might not appear during the installation CPAP Se ye Power on the system Insert the Ubuntu Desktop Linux operating system CD ROM or DVD into the system s CD or DVD drive Create a bootable array by following the procedure in Create Arrays on page 28 As soon as Ubuntu Desktop Linux kernel starts loading press F6 to go to Advanced Options Select the desired language and press Enter Press F6 Other Options Press ESC Press the down arrow to Install Ubuntu At the end of the Boot Options string add Type break mount and press Enter Software Installation 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 When the BusyBox shell is displayed perform the following steps Install the USB flash drive Type mount t vfat dev sdx1 tmp where x is the drive letter of the flash drive Type cp ap tmp dd
13. Utility The disk appears as a new disk the disk can appear with a legacy array When the new disk is initialized RAIDXpert 2 configuration data is written to the disk The disk state changes to Empty The disk appears as a legacy disk with a legacy array When the legacy array is deleted the state of the legacy disk changes to Empty The disk can now be used disk can contain valid data When a legacy array is deleted or when its corresponding legacy disk is initialized the data is lost legacy disk type changes to Disk The disk can now be used in RAIDXpert 2 arrays in RAIDXpert2 arrays See BIOS Configuration Utility for the disk initialization procedure and the appearance of legacy disks in the BIOS Configuration Utility Working with Arrays Create and Format Arrays RAIDXpert2 allows the partitioning and creation of as many as eight arrays across the system s disks Portions of disks can be used to create arrays at the same time that other arrays use different portions of the same disks 52 AMD RAIDXpert2 Graphical User Interface GUI Before you begin Review the issues and recommendations indicated in Table 21 Table 21 Creating arrays Issues and recommendations Issues Recommendations Access to arrays The creation of arrays even redundant arrays allows users immediate access to the arrays unless the Zero Create option is used during the Create process Array numbers Ar
14. a Critical state 69 An array is in an Offline state 70 Cannot assign a dedicated spare to an array 70 Cannot create a global spare 70 Cannot create an array larger than 2 199 TB 71 Recreate a deleted array 72 Disk errors 72 Modes for the rcadm program 79 rcadm Controller List elements 80 rcadm Disk List elements 80 rcadm Array List elements 81 RAIDXpert2 User Guide 7 RAIDXpert2 User Guide 8 Preface This user guide e Provides information about arrays disks and RAID levels RAID types e Describes how to improve storage system performance or reliability by understanding array and disk tasks and options e Describes how to acquire and load RAIDXpert2 drivers for Windows and Linux operating systems e Describes the features and procedures for using RAIDXpert2 which is the RAIDXpert2 GUI Intended audience This user guide is intended for use by system administrators and technicians who are experienced with the following e Direct Attached Storage DAS Storage Area Network SAN or Network Attached Storage NAS operators e Network administration e Network installation e Storage system installation and configuration Prerequisites Prerequisites for installing and configuring this product include familiarity with e Servers and computer networks e RAID and input output signal technology such as SCSI or SATA e Fibre Channel and Ethernet protocols Document conventions and symbols Table 1 Documen
15. available on your system Self Monitoring Analysis and SMART is a hard disk drive HDD capability which allows reporting of Reporting Technology SMART reliability information If a drive anticipates there is a high likelihood of future failure it triggers a SMART error condition RAIDXpert2 presents this error condition so the drive can be replaced before the predicted failure occurs RAIDXpert2 Feature Set i IMPORTANT The supported feature set for RAIDXpert2 Basic RAIDXpert2 Plus RAIDXpert2 VST or RAIDXpert2 VST Plus is determined by the license level that is included in the system BIOS Refer to the system s motherboard specifications for the supported features Table 4 Feature set for RAIDXpert2 by RAIDXpert2 license level Sub Features RAIDXpert2 RAIDXpert2 RAIDXpert2 RAIDXpert2 Basic Plus VST VST Plus 16 Getting Started Table 4 Feature set for RAIDXpert2 by RAIDXpert2 license level continued License Levels RAIDXpert2 RAIDXpert2 RAIDXpert2 RAIDXpert2 Basic Plus VST VST Plus Sub Features Nn 5 Z RAID levels supported Z Z o o Nn 5 Z z z Z RAIDABLE Volume Array creation No initialization Foreground initialization Background initialization Sparing Global Consistency check Background Scheduled Online capacity expansion OCE Online RAID level migration ORLM Drive disk roaming Same sys
16. be expanded perform the tasks indicated in Table 8 Table 8 Array expansion considerations For This Operating System Microsoft Windows Do This Format the arrays with NTFS Microsoft Corporation provides a utility Diskpart exe that can dynamically extend an NTFS file system onto any unused adjacent space Note also that using a single partition per array makes expansion much easier And Consider This 1 The Diskpart exe utility version depends on which version of the Windows operating system is running 2 The Diskpart exe utility can be found on the CD for some versions of Windows operating systems or on the Microsoft Corporation website http www microsoft com for other versions Use the correct version for the operating system Use an expandable file system Because RAIDXpert2 software is limited to eight arrays if a large number of logical volumes are needed use a logical volume manager LVM Expanding Disk Capacity Online Using OCE supported by RAIDXpert2 Plus Online Capacity Expansion OCE allows e Adding disks to an array at any time to increase an array s capacity e Accessing the array data while it is being redistributed To increase the size and organization of an array transform the array For more information about transforming arrays see Transform Arrays supported by RAIDXpert2 Plus on page 54 Migrating RAID Levels Online Using ORLM supported b
17. be reviewed in its entirety before configuring arrays Some of the advanced features of RAIDXpert2 such as sparing options must be understood by the user before creating arrays RAID Levels RAIDXpert2 supports the RAID levels indicated in Table 5 Table 5 RAID levels general characteristics RAID Level RAIDO striping Main Characteristic Provides the highest performance but no data redundancy Data in the array is striped distributed across several disks Supports 2 8 disks Use Usefulness RAIDO arrays are useful for holding information such as the operating system paging file where performance is extremely important but redundancy is not RAID 1 mirroring Mirrors data on a partition of one disk to another Supports 2 disks Useful when there are only two disks available and data integrity is more important than storage capacity RAIDS stripe with parity Stripes data as well as parity across all disks in the array Parity information is interspersed across the disk array In the event of a failure RAIDXpert2 can restore the lost data of the failed disk from the other surviving disks Supports 3 8 disks e Offers exceptional read performance as well as redundancy Write performance is not an issue due to the tendency of operating systems to perform many more reads than writes Requires only one extra disk to offer redundancy For most systems with three or more disks this i
18. disks and arrays Rescan All Channels on page 32 Change controller options Change INT13 boot support turn off Critical arrays or warning for Offline arrays while booting or change the number of disks that can be spun up when the system is powered on Change the Controller Options on page 32 Continue to boot Exit the BIOS Configuration Utility and continue booting the system Continue Booting from the BIOS Configuration Utility on page 33 Access the AMD RAID Controller BIOS Configuration Utility When booting the system press Ctrl R when the BIOS banner displays There is a maximum of three seconds to use this key combination to enter the BIOS Configuration Utility 2994 Ef NOTE If the BIOS Configuration Utility does not display contact your system or motherboard supplier Understanding the Color Code in the BIOS Configuration Utility Color codes indicate the type or status of information at the BIOS Configuration Utility See the table below Table 13 BIOS Configuration Utility color codes Color Description White text Indicates an available option or informational text Black text yellow highlighting Indicates an option or device for which action might be taken Yellow text Indicates information about the yellow highlighted option Green text Indicates an item that has been selected Light blue text Indicates that the item cannot be selected
19. displays when the user clicks Commit NOTE Unless the transformation is instantaneous the Array Status window updates to show the source and destination arrays along with the progress of the transformation Access Additional Space After an array has been transformed to a larger size use the operating system tools to access the additional space There are several possible methods for expanding the existing file system on an array that has been transformed to a larger size e Microsoft provides a command prompt utility called Diskpart exe that can expand any NTFS file system without requiring a reboot The Diskpart exe utility version to use depends on the version of Windows being run The Diskpart exe utility can be found on the CD that comes with some versions of Windows or at the Microsoft website http www microsoft com for others Use the correct version for the operating system e For arrays formatted with FAT32 use a third party application such as PartitionMagic from PowerQuest Corporation Restore Rebuild Arrays 56 With the Restore task a redundant type array whose state has changed to Critical can be restored rebuilt in one of two ways e By assigning a dedicated spare to the array e By creating a global spare or by using an existing global spare An existing global spare automatically starts restoring a redundant type array after the array s state changes to Critical An array in an Offli
20. has different names and paths for partitioning and formatting arrays and as such are outside the scope of this document For more information see your operating system s user documentation Name Arrays Naming an array can be useful when creating backups It makes an array easy to identify in a list of arrays 1 2 In the Array View section select the array to name At the Array menu select Name The Array Name window displays Type the desired name in the blank field 2994 NOTE The following characters are not allowed in an array name C fy gs IP cs a Click OK NOTE The array name appears in the Array List and in the BIOS Configuration Utility only 17 characters of the name are displayed in the BIOS Configuration Utility Transform Arrays Supported by RAIDXpert2 Plus With the Transform task an array can be 54 e Transformed from one RAID level to almost any other RAID level This function is also referred to as Online RAID Level Migration ORLM e Expanded dynamically even under I O load by adding disks to the array to increase the capacity of the array This function is also referred to as Online Capacity Expansion OCE AMD RAIDXpert2 Graphical User Interface GUI Before you begin Review the issues and recommendations indicated in Table 22 Table 22 Transforming arrays Issues and recommendations Issues Recommendations Array size An array cannot be transformed
21. is designed to maintain consistent arrays but it is good practice to run frequent consistency checks See Schedule a Consistency Check on page 60 When a redundant array is created using the Create command and the Skip Initialize option is not checked the default setting a Consistency Check is performed automatically Although a Consistency Check that runs during a Create task can be removed by highlighting the array and selecting Task gt Remove the array that is created is not redundant Unless a Consistency Check runs from end to end an array is not protected After a Consistency Check has been started adjust the priority of the Consistency Check task relative to user I O activity Use the Task Priority option see Change the Priority Level of a Task on page 59 A Consistency Check task can be scheduled with the Schedule Consistency Check task see Schedule a Consistency Check on page 60 RAIDXpert2 User Guide 59 Before you begin e The Consistency Check command can be started at any time on a redundant type array as long as another task is not running on the array e The Consistency Check command can be started while under I O load e Ifthe array state is Critical the Consistency Check fails e To estimate the remaining time for a Consistency Check look at the percentage of the task that is completed in hours minutes seconds These details are displayed next to the array in the Array View section of the Array Status wi
22. select Mirror gt Split 3 Select either Default or Advanced e If Default is selected the second volume will be hidden e If Advanced is selected the user can select disks from the mirror to be included in the primary array If enough healthy members remain the disks not selected will be split into a secondary array 4 Click Confirm Hide an Array Hide allows the user to hide the array from the operating system Hide an Array 1 Inthe Array View section select the array to hide 2 At the Array menu select Hide The array will disappear from the Array View EY NOTE Ifthe array is currently hidden select Array gt Un hide to display it Copy an Array Copy allows users to make copies of an existing source array data to a new destination array Copy an array 1 Inthe Array View section select the array to copy 2 Follow steps 1 through 7 in Create an array 3 Click Commit to start the Copy task amp NOTE The capacity of the created array must be equal to or larger than the capacity of the array being copied EY NOTE The array will be hidden Unlink Arrays Unlink is only used after a Copy is complete Prior to unlinking the source array and the destination array will both contain any data written to the source array After unlink is performed no data will be written to the destination copied array Unlink copied arrays 1 Inthe Array View section select the copy array to unlink 2 A
23. task for dedicated and global spares task control can only pause resume but it cannot remove the task To remove these types of tasks pause and then delete them f NOTE If a task is paused and then deleted the array is also deleted Deleting a task is the same as deleting an array data loss occurs Backup all data prior to deleting a task that involves a Transform or a Restore The tasks indicated in Table 9 can be displayed for each array Table 9 Types of tasks per array Task When Displayed Transform While an array is being transformed Create While an array is being created Consistency Check While verifying that the parity RAIDS RAID6 or mirror disk consistency is correct For redundant type arrays only Copy Copy allows users to make copies of an existing source array data to a new destination array Restore While an array is being restored Secure Erase While an array secure erase is being performed Check_Bitmap While verifying that the parity on a RAID5 RAID6 set or the mirror halves on a RAID or RAID 10 set are consistent This action is performed automatically to ensure that data is not corrupted whenever a system crashes Not_Active When no other tasks are being performed Understanding Disks Disks States Within the management applications a disk can be part of one or more arrays and can exist in one of three states Online Offline or SMART Error e In RAIDXpert2
24. the RAIDXpert 2 driver are sent to a message log file If desired change the name of this file in the Notification window By default notification events in Windows based systems are saved to Program Files RAIDXpert2 rc_service log Notification events in Linux based systems are saved to var log rc_service log At the View menu select Log to view the RAIDXpert2 messages Refresh the Display To refresh the display select Refresh at the View menu Working with Options Change Password Settings A password can be changed at the Options menu See Change a Password at the Options Menu on page 46 RAIDXpert2 User Guide 63 Set Event Notifications With the Notification option the user can manage event log and email notifications of events The Event View section of the Array Status window displays the priority listing The event log priority levels in ascending order are indicated in Table 26 Table 26 Event Log priority levels Event Priority Description Low Displays messages for normal system operations This event is not displayed unless requested by the user Informational Displays information that might be useful to know Warning The system user should to be informed about this event but probably does not need to take action Critical The system user must be informed about this event and should take action Fatal The RAIDXpert2 driver is fatally damaged and the RAID subsystem has shut down
25. the available space as a single array e The array size of the transformed array is limited to 2 199 TB on some operating systems RAIDXpert2 User Guide 83 Follow or Monitor Arrays and Disks rcadm follow The rcadm followorrcadm F command allows the user to follow or monitor arrays and disks It polls the RAID subsystem for any changes in status and sends an e mail notification and or executes a specified program The output of this command is logged to the System Event Log on Windows Before you begin It is recommended that the user not run more than one instance of rcadm follovw at the same time If the user runs more than one instance of the command each instance captures some of the events but no single instance captures all events 84 rcadm Command Line Interface Tool Glossary rcadm A command line interface CLI tool for managing RAID controllers Linux on Windows and UEFI operating systems It is used for creating transforming and deleting arrays and adding and removing disks legacy disk Legacy disks include new or unrecognized disks which may contain data or even an operating system Legacy disks appear in the BIOS Configuration Utility and in RAIDXpert2 as legacy arrays When the legacy disk is initializing configuration data is written to the disk The legacy array then becomes an online disk usable in arrays A CAUTION A legacy disk can contain valid data When a legacy disk is initialized a
26. these states are displayed in the Disk List section in a column named State See Table 16 on page 47 for additional information e Within the rcadm program these states are also displayed in a column named State See Table 41 on page 80 and Table 42 on page 81 for additional information The disk states are defined in Table 10 22 Arrays Disks and RAID Levels Table 10 Disk states Disk State When Displayed Whenever the disk is connected functioning correctly and RAIDXpert2 can communicate with it Whenever an unintialized new disk is connected Legacy Whenever a disk containing non RAIDXpert2 configuration data is connected Offline Whenever the disk fails and RAIDXpert2 detects an error condition on the disk SMART Error Whenever the disk reports a SMART error s to RAIDXpert2 If a disk fails it is displayed in the Disk List as Online until a rescan is performed If host I O is going to a failed disk and the disk is used in a single array the disk appears as Online in the Disk List but is highlighted in red the disk appears as Failed in Array View If host I O is going to a failed disk and the disk is used in multiple arrays the disk may appear in the Disk List as Offline and as Failed for each array in Array View After a rescan the Disk List state may change to Online After a rescan is performed the following can occur e A disconnected disk no longer appears in the Disk List although the disk ap
27. 1 Add or Remove Dedicated Spares 61 Add or Remove Global Spares 61 Use Mirror to Split an Array 62 Hide an Array 62 Copy an Array 62 Unlink Arrays 62 Secure Erase 63 Working with Views 63 Display or hide Controller Event Log panel 63 Log Window 63 Refresh the Display 63 Working with Options 63 Change Password Settings 63 Set Event Notifications 64 Licensing 64 Add space using a RAIDABLE Array 64 Troubleshooting67 Troubleshooting 67 System Startup Problems 67 Warning Messages POST Screen 68 Array Related Errors 69 Disk Related Errors 72 Troubleshooting Disks 73 Software License EULA75 Software License End User License Agreement EULA 75 Limited License to Authorized Distributors 75 Limited License to End Users 75 Restrictions 75 Proprietary Rights 76 Term and Termination 76 No Warranty 76 Limitation of Liability 76 Export Controls 76 General 77 rcadm Command Line Interface Tool79 What is rcadm 79 To Use rcadm with a Linux OS 79 To Use rcadm with a Windows OS 79 Manage Arrays and Disks rcadm manage 80 Understand Query Output 80 rcadm Controller List Elements 80 rcadm Disk List Elements 80 rcadm Array List Elements 81 View Help from the Command Line 82 Create New Arrays rcadm create 82 Before you begin 83 Example 83 OONDOOaARWND RAIDXpert2 User Guide Delete Arrays rcadm delete 83 Before you begin 83 Example 83 Transform Arrays rcadm transform Supported by R
28. 23 Sparing Options Disks and Arrays 24 Dedicated Sparing 24 Global Sparing 24 RAID Performance Considerations 25 Number and Organization of Disks 25 Caching Attributes 25 Application Workload 25 RAID Reliability Considerations 25 Data Redundancy 25 Backup 25 Flexibility and Expansion Considerations 25 Multiple RAID Levels 25 RAIDABLE Arrays 26 4 BIOS Configuration Utility27 When to Use the AMD RAID Controller BIOS Configuration Utility 27 Access the AMD RAID Controller BIOS Configuration Utility 27 Understanding the Color Code in the BIOS Configuration Utility 27 Initialize Disks 28 Initialize Disks 28 Create Arrays 28 Before you begin 28 Create An Array 29 RAIDXpert2 User Guide 3 Delete Arrays 30 Delete an Array 30 Swap Arrays 30 Before you begin 30 Swap Arrays 31 Manage Spares 31 Assign Global Spares 31 Assign Dedicated Spares 31 Unassign Spares 31 View Disk Details 32 View Array Details 32 Rescan All Channels 32 Change the Controller Options 32 Booting the system from an array 33 Pausing the boot sequence for warning messages 33 Change the Staggered Spinup Count 33 Continue Booting from the BIOS Configuration Utility 33 Resume the Boot Process 33 Software Installation35 System setup process overview 35 Before you begin 35 Copying AMD RAID drivers to removable storage 35 Copying AMD RAID drivers in a Microsoft Windows environment 35 Copying AMD RAID drivers in a Linux environment 35 Pre installation steps
29. AIDXpert2 Plus 83 Before you begin 83 Follow or Monitor Arrays and Disks rcadm follow 84 Before you begin 84 Glossary85 Index87 Tables OANOOARWN Document conventions 9 System requirements for RAIDXpert2 13 Features of RAIDXpert2 14 Feature set for RAIDXpert2 by RAIDXpert2 license level 16 RAID levels general characteristics 19 Array states 20 Failure states by RAID level 20 Array expansion considerations 21 Types of tasks per array 22 Disk states 23 Sparing options 24 When to use the AMD RAID Controller BIOS Configuration Utility Option ROM 27 BIOS Configuration Utility color codes 27 Linux procedure for installing the Management Suite 42 Elements of the Array View section Array Status window 47 Elements of the Disk List section Array Status window 47 Elements of the Array List section Array Status window 48 Elements of the Event View section Array Status window 49 Commands at the Array and Disk menus 50 New and legacy disks as they appear in the BIOS Configuration Utility and RAIDXpert2 52 Creating arrays Issues and recommendations 53 Transforming arrays Issues and recommendations 55 Deleting arrays Issues and recommendations 58 Cache array options 58 Consistency Check options 60 Event Log priority levels 64 The system does not boot 67 The BIOS Configuration Utility does not display 67 Username and password 67 POST screen warning messages 68 Cannot create an array 69 An array is in
30. B continued Possible Causes Additional Information Corrective Actions 16 Click Next gt 17 Follow the normal formatting procedure for a disk After the array initializes it displays at the Computer Management window Table 37 Recreate a deleted array Possible Causes Additional Information Corrective Actions An array s was accidentally This procedure might recreate 1 At the Array pop up menu select Create deleted or the wrong array ja deleted array and with its Create a new array using the same settings as the deleted was deleted data intact However this is array not guaranteed to occur The same disks If T O was running to the The same RAID type RAID level deleted array s just prior to it being deleted there might be some data loss in the e The same cache options e The same capacity recreated array s Check Leave Existing Data Intact If multiple arrays were Click Create deleted all of the deleted Ensure the settings are the same as the deleted array arrays must be recreated in The same drive letter er ae asec The same RAID type RAID level pe The same disks The same capacity The same cache option Check the data files of the array for corrupted or missing files incorrect file extensions and so on Disk Related Errors e Disk errors on page 72 e Troubleshooting Disks on page 73 Table 38 Disk errors JA disk has been removed from an array 0 See Troubleshoot
31. D RAID drivers while installing Microsoft Windows NOTE The windows described in this guide are typical Path names and text can vary depending on user designated selections and other parameters Installing AMD RAID drivers during a Microsoft Windows XP installation 1 Power on the system amp NOTE Do not boot up with a USB flash key in the system when performing an install as the system will use that as the boot device 2 Create a bootable array by following the procedure in Create Arrays on page 28 Insert the Microsoft Windows operating system CD ROM or DVD into the system s CD or DVD drive 4 Boot the system and allow it to access the Microsoft Windows operating system CD ROM or DVD Ge NOTE For Windows XP press F6 immediately 5 At the applicable Windows setup window perform the following steps e For Windows XP 32 bit SP3 e Press F6 to install the drivers e At the driver selection window press S to select a third party driver e Browse to the location of the driver and press Enter 6 Follow the on screen instructions to complete the installation of the applicable Windows operating system 7 After the OS is installed open Device Manager At Other Devices right click on AMD Configuration Device Select Update driver software Select Browse and navigate to the storage medium Click OK Click Next If the Windows Security pop up menu appears click Install or similar Click Clos
32. DXpert2 46 settings changing 63 things to know 46 performance considerations 25 physical disks errors 72 troubleshooting 72 POST screen warning messages 68 prerequisite knowledge 9 Q query output understanding it using rceadm 80 R RAID levels general characteristics 19 online migrating 21 RAID types see RAID levels 19 RAIDXpert2 array hiding 14 array recovery 14 arrays general information 14 background array initialization BGI 14 cache support for arrays 14 cache support for disks 14 consistency check 14 current availability of its functions 16 disk roaming 15 fault tolerance 15 license levels 16 main features 14 mirror rebuilding 15 multiple RAID levels per disk 15 Native Command Queuing NCQ 15 Online Capacity Expansion OCE 15 Online RAID Level Migration ORLM 16 RAID level support 16 Secure Erase 14 Self Monitoring Analysis and Reporting Technology SMART 16 supported controllers 13 supported operating systems 13 system requirements 13 technology general description 13 rcadm array list elements 81 controller list elements 80 create new arrays 82 RAIDXpert2 User Guide 88 delete arrays 83 disk list elements 80 follow arrays 84 manage arrays and disks 80 monitor arrays 84 transform arrays 83 understanding query output 80 viewing Help 82 what it is 79 rebuild restore task rebuilding restoring a Critical array 56 redundancy data 25 reliability considerations 25 remote management se
33. Installation Settings window verify that the settings are correct and click Install At the YaST2 Confirm Installation window review the text and click Install Wait while the Perform Installation process runs and then reboot the system when prompted RAIDXpert2 User Guide 39 16 17 18 19 20 21 22 23 24 25 26 When the installation is finished remove the USB flash drive and the SUSE Linux operating system CD or DVD from the system and reboot the system At the Password for the System Administrator root a Type the applicable root password b Re type the root password c Click Next Enter a Hostname enter a Domain Name and then click Next At Network Config configure all that apply a Setup General Network Settings b Setup Firewall Setup Network Interface s Setup ISDN Adapter Setup Modems Setup VNC Remote Administration Setup Proxy Click Next i At the Test Internet Connection select an option and then click Next sr me ae At Installation Overview setup Ca Management and then click Next Setup User Authentication Method and then click Next Setup New Local User and then click Next Review Release Notes and then click Next At the Hardware Configuration configure all that apply a Setup Graphic Card b Setup Printer c Setup Sound d Click Next At the Installation Complete select unselect Clone This System and then click Finish Proceed to Installing the AMD
34. Line Interface Tool Table 41 rcadm Disk List elements Element Description Total size of the disk e 1 MB 1 000 000 bytes e 1 GB 1 000 000 000 bytes aa amp NOTE Because the ATA storage industry has standardized the meanings of MB as 1 000 000 bytes and GB as 1 000 000 000 bytes RAIDXpert2 reports the same units Free Space Total amount of space unused on the disk Largest Free Space Largest contiguous unused space on the disk Indicates if the disk is assigned as a global spare Current disk cache setting NC No Cache R Read Cache W Write Back Cache RW Read Write Back Cache Ctrl Chan Disk controller and channel number Vendor Disk vendor Model Number Disk model number Firmware Version Disk firmware version Serial Number Disk serial number rcadm Array List Elements Table 42 rcadm Array List elements Element Description Array number assigned by RAIDXpert2 RAID type Name assigned by the operating system to the array The name shows as Hidden if the array is hidden from the operating system The name shows if the array is Offline Sys or System Device Indicates whether or not the array is being used as a system disk under Windows State State of the array Normal Critical Offline Size or Capacity Total size of the disk e 1 MB 1 000 000 bytes e 1 GB 1 000 000 000 bytes
35. Select Schedule 4 At the Check Consistency window select the Frequency Day and Time 5 Click Confirm Delete a scheduled Consistency Check In the Array View section select the array to on which to delete the Consistency Check At the Array menu select Check Consistency Select Schedule At the Consistency Check window click Remove ae Ne E 60 AMD RAIDXpert2 Graphical User Interface GUI Scan an Array in the Background A Background Array Scan task performs a continuous background read operation of an array accessing at least one copy of every block of the array from beginning to end A Background Array Scan is manually started by the user and runs continuously until the user stops it Although a Background Array Scan can run while an array is engaged in other tasks it is recommended that the Background Array Scan run while the array is idle that is when there is no I O to or from the array Enable or disable a Background Array Scan 1 2 3 In the Array View section select the array to on which to run the Background Array Scan At the Array menu select Background Array Scan Enabled or disable the Background Array Scan e To enable a Background Array Scan select Start e To disable a Background Array Scan select Stop NOTE A Background Array Scan can also be enabled for an array when it is created or copied Add or Remove Dedicated Spares If a dedicated spare is added make sure there is a
36. TA cables can be disconnected from their disks and shuffled without confusing RAIDXpert2 NOTE Disconnect the SATA cables from the disks only when the system is shutdown Disk roaming also allows e Disks to be moved to different slots in the backplane RAIDXpert2 detects which disks belong to which arrays regardless of where the disks are moved in the backplane Disk s to be moved between systems NOTE It might not be possible to move disks between systems in boot arrays Fault tolerance The following fault tolerance features are available with RAIDXpert2 in order to prevent data loss in case of a failed disk e Disk failure detection automatic e Array rebuild using hot spares automatic if the hot spare is configured for this functionality Parity generation and checking RAIDS only Hot swap manual replacement of a disk without rebooting the system available only for systems with a backplane that supports hot swapping For example if a disk fails in RAID1 the array remains functional and data is read from the surviving mirrored disk Mirror rebuilding A broken mirrored array can be rebuilt after a new disk is inserted and the disk is designated as a spare The system does not have to be rebooted Multiple RAID levels per disk Support for multiple array levels per disk allows the administrator to create arrays of different RAID levels using the same disks Native Command Queuing NCQ Nat
37. Test POST screen e Problems with arrays e Problems with disks System Startup Problems e The system does not boot on page 67 e The BIOS Configuration Utility does not display on page 67 Table 27 The system does not boot Possible Causes Corrective Actions Controller mode is set In the system s BIOS screen ensure SATA settings are in RAID mode incorrectly during system startup The system s boot mode or In the system s BIOS screen ensure that the bootable array is the first array boot sequence retry mode is listed set mcorrectly If not use the Swap Two Arrays option to reposition the arrays A bootable array is in an Offline state 1 Restart the system 2 Enter the system s BIOS screen 3 Check the state of the bootable array 4 Check for missing or offline disks Table 28 The BIOS Configuration Utility does not display Possible PossibleCauses Corrective Actions sd Actions posse canes controller mode is set correc Aeon a I I the system s BIOS screen ensure the SATA settings are correct incorrectly in the system BIOS Table 29 Username and password Problem Corrective Actions sd Actions Prete _ user forgets the username or poreon the username and password by deleting rc_login txt This restores password the default user name and password admin and admin RAIDXpert2 User Guide 67 Warning Messages POST Screen The POST screen is one of the first screens to appe
38. Type dd pre_install Type umount tmp mean oe Type exit Wait for the Welcome screen to appear Select the desired Language and click Continue Accept the defaults and click Continue Select Erase Disk and install Ubuntu and then click Continue From the Select Drive drop down menu select the AMD Array and then click Install Now Select the desired Time Zone and click Continue Select the desired Keyboard layout and click Continue Enter valid entries for the following Your name Computer name User name Password cap op Confirm Password Click Continue When the Installation Complete window is displayed perform the following steps a Press CTRL ALT F1 b Enter sudo mount t vfat dev sdx1 mnt where x is the drive letter of the flash drive c Enter sudo cp ap mnt dd d Entersudo dd post_install Wait for the Setup is Complete message and then press CTRL ALT F7 Click Restart Now to finish the installation When prompted to remove the installation media remove the CD DVD and USB flash drive from the system and press Enter Proceed to Installing the AMD RAIDXpert2 Management Suite for Linux on page 42 Installing the AMD RAIDXpert2 Management Suite for Microsoft Windows Obtain the latest Catalyst executable file from your system supplier or motherboard vendor Download the file to the system s Desktop and execute it Follow the on screen prompts See Browser setup on page 45 for suppo
39. after a task is running on the array To change a task priority 1 Inthe Array View section select the array on which tasks are being performed 2 At the Array menu select Task and select Priority 3 At the Task Priority window change the task priority by moving the slide one way or the other 4 Click OK Interrupt Cancel or Resume a Task The task control commands allow the user to pause resume or cancel remove tasks being performed on arrays Full task control can be used on Create Consistency Check and Check Bitmap tasks On Restores with dedicated or global spares the task can be removed but the array returns to the Critical state NOTE Task control can be used only when a task is running on an array Interrupt cancel or resume a task 1 Inthe Array View section select the array on which a task is being performed 2 At the Array menu select Task and click e Pause to interrupt the task e Remove to cancel the task e Resume to interrupt the task Check for Consistency For redundant type arrays only the Consistency Check task is available at the Array menu When this task is selected it starts the process of verifying that the parity RAID5 or RAID6 or mirror drive consistency for fault tolerant disks is correct If inconsistent areas are found they are corrected during this process Having consistent arrays is very important If an array is inconsistent and a drive fails data is lost RAIDXpert2
40. alization a status indicator shows which disk is being initialized When the initialization is complete the status indicator turns off A complete rescan of all channels is done automatically during initialization Create Arrays Arrays can be created after the disks are initialized See RAID Levels on page 19 for deciding what type of RAID levels to use for the array X TIP See also Create and Format Arrays on page 52 and Create New Arrays rcadm create on page 82 Before you begin e In some circumstances more than eight arrays are possible They might appear to function properly but are not supported by AMD RAID e For redundant arrays the Create process is not finished until after the operating system and AMD RAID OS drivers have been installed and the system has booted to the operating system However the arrays are immediately available to use for either a bootable array or a data array e Array numbers are valid only for a given boot and might be different in the BIOS Configuration Utility and RAIDXpert2 If a permanent label is required use the Array Naming feature 28 BIOS Configuration Utility e At any point in the procedure return to a prior window by pressing Esc e Ifthe system is booted from an AMD RAID bootable array the first array in the Arrays section must be the bootable array The system boots only from the first array in the Arrays section As necessary use the Swap Two Arrays feature to swap arra
41. ally true for a non redundant bootable array Initializing a disk in a non redundant bootable array causes the array to Fail and deletes the operating system RAIDXpert2 files and device drivers A CAUTION Leaving Write Back Cache enabled can increase the likelihood of data being corrupted if the system experiences a power interruption or unexpected shutdown A CAUTION Prior to removing an array remove its drive letter Windows or unmount the array Linux A CAUTION Alldata contained in a RAIDXpert2 array are lost if the RAIDXpert2 disks of the array are migrated to a non RAIDXpert2 system A CAUTION When an array is securely erased the data on the array is lost A CAUTION In some circumstances more than eight arrays are possible They might appear to function properly but are not supported A CAUTION Creating a redundant array with Skip Initialization selected can result in data corruption Safety Precautions 2 Getting Started RAIDXpert2 Technology RAIDXpert2 consists of a storage management and b a RAID controller and port virtualization RAIDXpert2 runs on existing systems by using a motherboard s built in SATA ports Who Should Use This Manual Only trained experienced and authorized personnel should install RAIDXpert2 and use its features and capabilities All unit operators must be familiar with system hardware data storage RAID technology input output signal t
42. apply to non redundant RAID levels To protect data transform the array to a redundant RAID level Spares can then be assigned Be aware that the Transform task is supported only by RAIDXpert2 Plus RAIDXpert2 VTS and RAIDXpert2 VTS Plus Dedicated Sparing A dedicated spare is a disk that is assigned as an alternate disk for a specific array Should a disk fail in that array the alternate disk is used to replace the failed disk and the array is rebuilt A dedicated spare can be assigned to any redundant array type and up to four spares can be assigned to an array A CAUTION Assigning a dedicated spare does not reserve space on the disk Therefore an automatic restore is not guaranteed if a disk fails If a disk fails make space on the disk for the fail over to complete or assign a different disk with enough space If a dedicated spare is assigned and a disk fails the restore process starts automatically if there is enough space available on the dedicated spare For additional information see Add or Remove Dedicated Spares on page 61 Global Sparing A global spare is a disk that is assigned as an alternate disk for multiple arrays instead of associating it with only one array Many arrays can be restored using the global spare disk as long as it is not already part of the array and it has enough space available Unlike a dedicated spare this type of spare can be assigned at any time even while tasks are running on arrays
43. ar during the system s boot sequence If the system s arrays were in Normal or Ready state prior to a system boot the boot sequence continues normally to the operating system But if an array is in Critical or Offline state or if specific options at Controller Options were changed previously at the BIOS Configuration Utility the warning messages described in Table 30 appear during the boot sequence Table 30 POST screen warning messages Warning Message Additional Information Corrective Action or equivalent or equivalent User BIOS BIOS NOT Disabled oad or equivalent 68 Troubleshooting INSTALLED INT13 This warning message appears when at least one array is in a Critical state and Toggle Pause if Critical is set to ON at the BIOS Configuration Utility The Critical state of an array depends on the RAID level of the array and the number of disks that have failed See Array States on page 20 for information on criticality If an array is Critical even a bootable array the system can continue through the boot process to the operating system This warning message appears when at least one array is in an Offline state and Toggle Pause if Offline is set to ON at the BIOS Configuration Utility If two or more disks in a redundant array have failed or if a single or multiple disks in a non redundant array have failed data has been lost In RAID10 array if a
44. ask STARTED PAUSED COMPLETED the progress of the task is given in the Array View section Pri Task priority if a task is in progress 48 AMD RAIDXpert2 Graphical User Interface GUI Table 17 Elements of the Array List section Array Status window continued a Prepi OOOO oo oo Background Array Scan enabled Yes No Current cache setting NC No Cache R Read Cache WB Write Back Cache RW Read Write Cache The Event View Section of the Array Status Window Elements of the Event View Section The Event View section is an optional view section It can be displayed or hidden by selecting View gt Event View The information in the Event View is linked to the View Log The View Log displays user initiated tasks or actions and system generated notifications and events The View Log can be accesses by selecting View gt Log The Event View provides information about the events Table 18 provides information about the elements of the Event View section Table 18 Elements of the Event View section Array Status window Description The number of the event The date and time at which the event occurred The RAIDXpert2 Asynchronous Event Notification AEN number of the event The notification priority of the event Low Informational Warning Critical or Fatal A brief description of the event Array and Disk Commands The Array and Disk menus of the Array Status windo
45. ay size 5 TB volumes Dynamic volumes Divide 5 by 2 199 2 27 can be striped together using the Windows Disk Bounddown a2 Management utility to create Create 2 maximum sized arrays arrays larger than 2 199 TB b If the division results in a number with a decimal from groups of smaller arrays create one more array the size of the remainder Multiply the whole number of arrays by 2 199 Subtract from the size of the desired array The resulting number is the size of the remaining array Example Multiply 2 by 2 199 4 398 Subtract 4 398 from 5 0 602 The size of the remaining array must be 0 602 TB N From the desktop right click My Computer Click Manage At Computer Management Local select Storage gt Disk Management A w The Initialize and Convert Disk Wizard window opens Select the disks Click Next gt nN wn NO This procedure requires converting disks to dynamic disks In normal operation this is not recommended N Select the disks 8 Click Next gt 9 Click Finish The arrays are displayed in the Computer Management window 10 Right click the first disk 11 Click New Volume 12 Click Next gt 13 Click Spanned This type of volume merges the disks together 14 Click Next gt The New Volume Wizard opens 15 Choose the desired disks and the size of the resulting volume RAIDXpert2 User Guide 71 Table 36 Cannot create an array larger than 2 199 T
46. be modified rather than voided if possible in order to achieve the intent of the parties to the extent necessary to make the provision enforceable under applicable law and enforced as amended In any event all other provisions of this Agreement will be deemed valid and enforceable to the full extent This Agreement constitutes the complete agreement between the parties and supersedes all prior or contemporaneous agreements or representations written or oral concerning the subject matter of this Agreement including any purchase order or ordering document This Agreement may not be modified or amended except in writing and signed by both parties RAIDXpert2 User Guide 77 78 Software License EULA 9 rcadm Command Line Interface Tool What is rcadm The rcadm program is a command line interface CLI tool for managing RAIDXpert2 in the Windows Linux or EFI operating system The rcadm program initiates RAIDXpert2 operations such as Manage RAIDXpert2 arrays and disks see page 80 Create new arrays see page 82 Delete arrays see page 83 Transform arrays see page 83 supported by RAIDXpert2 Plus Follow or monitor arrays and disks see page 84 Information on drive and array states The rcadm program has seven primary modes with most primary modes having additional optional arguments The seven modes of operation are indicated in Table 39 Table 39 Manage Uses the rcadm disks Modes for the rcadm pro
47. ction select the desired option amp NOTE Selecting any option first initializes the disk before the selected task is started a Backup Array This option creates a backup of the RAIDABLE array on the new disk b Transform Array This option allows the user to either add space to the RAIDABLE array or create a redundant array c Initialize Disk for AMD RAID This option allows the disk to be used when creating arrays d Make disk a Global Spare This option assigns the new disk as a global spare 4 In the Select a Source Destination section a Select the Source RAIDABLE Array from the drop down menu b Select the Destination Array Type from the drop down menu Ey NOTE The Destination Array Type option is only available when either the Backup Array task or Transform Array task is selected Only valid array types for the number of disks inserted will be displayed For example if one new disk is inserted only RAIDO or RAID1 will display in the drop down menu 5 Click Confirm If either the Backup Array task or Transform Array task is selected a Task Progress dialog box displays To hide the dialog box while the task is executing click Close RAIDXpert2 User Guide 65 66 AMD RAIDXpert2 Graphical User Interface GUI 7 Troubleshooting Troubleshooting The chapter discusses four major categories of troubleshooting e Problems with system startup e Warning messages that might appear at the Power On Self
48. d Software for purposes of this Agreement The Software is not absolutely fault tolerant and is not designed manufactured or intended for use or resale as on line control equipment in hazardous environments requiring fail safe performance in which the failure of the Software could lead directly to death personal injury or severe physical or environmental damage such as the operation of nuclear facilities aircraft navigation air traffic control direct life support machines or weapons systems High Risk Activities Express or implied warranties for High Risk Activities are specifically disclaimed 7 Limitation of Liability IN NO EVENT SHALL DOT HILL AMD OR LICENSORS BE LIABLE TO ANY PARTY FOR ANY LOST REVENUE LOST PROFIT OR DATA OR FOR SPECIAL INDIRECT CONSEQUENTIAL INCIDENTAL OR PUNITIVE DAMAGES HOWEVER CAUSED AND REGARDLESS OF THE THEORY OF LIABILITY ARISING OUT OF THE USE OF OR INABILITY TO USE THE SOFTWARE EVEN IF THEY HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN NO EVENT SHALL DOT HILL S AMD s or LICENSORS LIABILITY TO YOU WHETHER IN CONTRACT TORT INCLUDING NEGLIGENCE OR OTHERWISE EXCEED THE AMOUNT OF ANY FEE PAID BY YOU FOR THE SOFTWARE THE FOREGOING LIMITATIONS SHALL APPLY EVEN IF THE REMEDY FAILS OF ITS ESSENTIAL PURPOSE Some jurisdictions do not allow for the exclusion of implied warranties as described in Section 6 or the limitation of liabilities as described in this Section 7 so the above exc
49. dequate space on the dedicated spare Add a dedicated spare 1 a ee In the Array View section select the array on which to assign a dedicated spare In the Disk List section select the disk chosen as the dedicated spare At the Disk menu select Spare Identify Select Assign as Dedicated Spare Click Confirm Remove a dedicated spare assignment Soe eS In the Array View section select the array from which to remove a dedicated spare At the Disk menu select Spare Identify Select Remove as Dedicated Spare Click Confirm X TIP For additional information see Sparing Options Disks and Arrays on page 24 Add or Remove Global Spares If a global spare is being added make sure there is adequate space on the global spare Add a global spare 1 2 3 4 In the Disk List section select the disk chosen as the global spare At the Disk menu select Spare Identify Select Assign as Global Spare Click Confirm Remove a global spare Pe a In the Disk List section select the disk to be removed as the global spare At the Disk menu select Spare Identify Select Remove as Global Spare Click Confirm RAIDXpert2 User Guide 61 Use Mirror to Split an Array Mirror split allows a RAID1 configuration to be split into two volumes NOTE One of the resulting volumes will be hidden by default Split an array 1 Inthe Array View section select the RAID1 array to split 2 At the Array menu
50. des information about the four array caching options available 58 Table 24 Cache array options Option Description No Cache TO requests are translated and passed to the disks without keeping a cached copy of the data available for future requests Read Cache Data reads are cached if appropriate This option performs sequential Read Ahead when necessary Write Back Cache Data writes are cached This setting is intended for advanced users who understand the implications of Write Back caching Read Write Back Cache default setting Both Read and Write Back Cache options can be selected 2994 NOTE Cache options cannot be changed while a task is active on the array They can be changed at any other time including while I O is running AMD RAIDXpert2 Graphical User Interface GUI Change cache settings 1 Inthe Array View section select the array on which to change caching options 2 At the Array menu select Modify Cache Settings 3 Choose No Cache Read Cache Write Back Cache or Read Write Back Cache The new cache setting displays in the Array List Cache information Change the Priority Level of a Task The task priority command allows the user to speed up or slow down tasks being performed on arrays To decrease the amount of time it takes for a task to complete set the task priority higher 10 is the highest 2994 NOTE A task priority can only be changed
51. e 8 Reboot the system 9 After the OS has booted up see Windows Install the AMD RAIDXpert2 Management Suite 10 Remove the storage medium and Microsoft Windows OS CD ROM or DVD from the applicable drive s and port mre an sp Installing the AMD RAID drivers during a Microsoft Windows Vista Windows 7 or Windows 8 installation 1 Power on the system NOTE Do not boot up with a USB flash key in the system when performing an install as the system will use that as the boot device 2 Create a bootable array by following the procedure in Create Arrays on page 28 Insert the Microsoft Windows operating system CD ROM or DVD into the system s CD or DVD drive 4 Boot the system and allow it to access the Microsoft Windows operating system CD ROM or DVD RAIDXpert2 User Guide 37 5 At the applicable Windows setup window perform the following a Insert the storage medium with the AMD RAID drivers into the USB port or applicable system drive b Enter the requested information at the Install Windows window c At the Load Driver window click Browse d Locate and select the applicable driver and then click OK e At the Select the driver to be installed window review the selected driver if correct click Next 6 Follow the on screen instructions to complete the installation of the applicable Windows operating system 7 After the OS is installed open Device Manager At Other Devices right click on AMD Configuration Dev
52. e Cannot create a global spare on page 70 e Cannot create an array larger than 2 199 TB on page 71 e Recreate a deleted array on page 72 Table 31 Cannot create an array Possible Causes Additional Information Corrective Actions The disk is not displayed The controller cannot communicate with the See Troubleshooting Disks on page 73 disks Insufficient free space Select a different combination of disks available on the selected disks Incorrect number of disks See RAID Levels on page 19 for a description Select the correct number of disks selected for the desired RAID of RAID levels and the allowable number of level disks used with each RAID level The desired disk is The disk is a dedicated spare for a Select a different disk unavailable different array The disk is full The disk s available capacity is insufficient The disk has SMART errors An array can be created with a disk that has Use the BIOS Configuration Utility to create SMART errors but only if the array is created the array in the BIOS Configuration Utility RAIDXpert2 cannot be used to create an array with a disk that has SMART errors The system already has a Delete unused arrays maximum of eight arrays A CAUTION Deleting an array permanently destroys all data that is on the array This action cannot be undone and it is very unlikely the data can be recovered Table 32 An array is in a Critical state Possible Causes Additiona
53. e disk as a dedicated spare select Assign as Dedicated Spare NOTE The capacity of a dedicated spare must be equal to or larger than the capacity of the smallest disk in the array e To use the disk as a global spare select Assign as Global Spare 4 Click Confirm Legacy Disks A legacy disk is a disk that contains valid data from a non RAID controller A legacy disk appears in RAIDXpert2 and in the BIOS Configuration Utility with a corresponding legacy array When the legacy disk is initialized in RAIDXpert2 or in the BIOS Configuration Utility the legacy array disappears A CAUTION A legacy disk can contain valid data When a legacy array is deleted or when its corresponding legacy disk is initialized the data is lost Legacy disks and New disks Table 20 provides information on how disks appear in RAIDXpert2 and in the BIOS Configuration Utility Table 20 New and legacy disks as they appear in the BIOS Configuration Utility and RAIDXpert2 Status of the Disk New un initialized disk A disk containing non RAIDXpert2 configuration data A CAUTION A legacy In RAIDXpert2 The disk appears as a new disk with a legacy array When the new disk is initialized its state changes to Online or similar The disk appears as a legacy disk with a legacy array When the legacy disk is initialized or the legacy array is deleted the legacy array disappears and the In the BIOS Configuration
54. e disks Query information about disks Add and remove spares from an array Set cache attributes for disks Understand Query Output When the rcadm manag query all command is used information about the disks and arrays for the system is displayed To see information about a specific controller disk or array use the rcadm manag query command in conjunction with the appropriate options rcadm Controller List Elements Table 40 rcadm Controller List elements Element Description Number Controller number assigned by RAIDXpert2 Type Model number of the controller Serial Number Serial number of the controller Port Count The number of ports supported by RAIDXpert2 PCIe Vendor ID The PCIe vendor identification number PCIe Device ID The PCIe device identification number PCIe SubVendor ID The PCIe sub vendor identification number PCIe SubDevice ID The PCIe sub device identification number SAS Address WWID The SAS Address world wide identification number BIOS Version The version of the AMD RAID Configuration BIOS rcadm Disk List Elements Table 41 rcadm Disk List elements Element Description 80 Disk number assigned by RAIDXpert2 corresponding to the SATA channel ID State of the disk Online Failed Unknown Disk type Disk Legacy New ATAPI Port type SATA SATA II eSATA SSD The negotiated speed of the port rcadm Command
55. e source RAIDXpert2 User Guide 73 74 Troubleshooting 8 Software License EULA Software License End User License Agreement EULA BY INSTALLING DOWNLOADING AND OR USING THE SOFTWARE THAT ACCOMPANIES THIS END USER LICENSE AGREEMENT AGREEMENT AND ANY ASSOCIATED DOCUMENTATION OR UPDATES THERETO SOFTWARE YOU AGREE THAT WHETHER AS AN INDIVIDUAL OR AUTHORIZED REPRESENTATIVE OF AN ENTITY YOU HAVE READ THIS AGREEMENT UNDERSTAND IT AND AGREE TO BE BOUND BY IT IF YOU DO NOT AGREE TO IT YOU ARE NOT AUTHORIZED TO INSTALL DOWNLOAD OR OTHERWISE USE THE SOFTWARE AND ARE ASKED TO PLEASE RETURN THE SOFTWARE TO THE PARTY FROM WHOM YOU RECEIVED IT THE RIGHT TO USE THE SOFTWARE IS GRANTED ONLY UPON THE CONDITION THAT YOU AGREE TO THE TERMS AND CONDITIONS OF THIS AGREEMENT FURTHER YOU UNDERSTAND THAT THIS SOFTWARE MAY ONLY BE OBTAINED FROM Advanced Micro Devices Inc AMD OR AN AUTHORIZED DISTRIBUTOR OF AMD IF YOU OBTAINED THIS SOFTWARE FROM ANY OTHER SOURCE THAT SOURCE PROVIDED IT TO YOU ILLEGALLY AND YOU HAVE NO RIGHT TO INSTALL DOWNLOAD OR OTHERWISE USE THE SOFTWARE SUCH USE IS A VIOLATION OF INTELLECTUAL PROPERTY RIGHTS 1 Limited License to Authorized Distributors If you are an OEM distributor reseller integrator or other entity in the business of providing technology products and or services and if you have been expressly authorized to distribute copies of the Software to End User s you are an Authorized D
56. echnology such as SCSI SAS or SATA and Direct Attached Storage DAS Network Attached Storage NAS and or Storage Area Network SAN concepts and technology The intended user audience of this user manual is system administrators and experienced users System Requirements for Using RAIDXpert2 Make sure the systems that use RAIDXpert2 meet the requirements indicated in Table 2 Table 2 System requirements for RAIDXpert2 Component Requirements Memory RAM Minimum 1 GB Recommended 2 GB Hard disk 1 12 SATA or SSD drives The number of disks depends on the number type and capacity of the arrays to be created In some circumstances more than 12 disks are possible They might appear to function properly but are not supported by AMD RAID Supported Controllers The following controllers are supported by the current release of RAIDXpert2 e A amp x Series e A7x Series Supported Operating Systems The following operating systems are supported by the current release of RAIDXpert2 e Microsoft Windows 8 32 bit and 64 bit e Microsoft Windows 7 Professional Edition Ultimate Edition 32 bit and 64 bit e Microsoft Windows Vista SP2 Business Edition Ultimate Edition 32 bit and 64 bit e Microsoft Windows XP 32 bit SP3 e SUSE Linux Enterprise Desktop 10 SP4 and 11 SP2 32 bit and 64 bit e Ubuntu Desktop 12 04 1 and 12 10 32 bit and 64 bit RAIDXpert2 User Guide 13 Features of RAIDXp
57. emove its drive letter Windows or unmount the array Linux In the Array View section select the array to remove Atthe Array menu select Prepare to Remove 3 At the Prepare to Remove window click Yes The array and all associated disks disappear from the Array aA wep Status window Remove the first disk from the system When the Drive Removed window displays click Cancel Remove the remaining disks in the array When all disks in the array have been removed from the system select Rescan at the Disk menu Array migration The disks in an array after being removed from one system with a RAIDXpert2 controller can be migrated to another system with a RAIDXpert2 controller The disks and array s appear in the second system in Disk Management the BIOS Configuration Utility and RAIDXpert2 as normal RAIDXpert2 disks and array s If the disks from a RAIDXpert2 system are migrated to a non RAIDXpert2 Windows based system the disks appear in Disk Management of the second system as healthy unknown partitions To use the disks use Disk Management to delete the RAIDXpert2 created partitions and to create Windows partitions on the disks A CAUTION All data contained in a RAIDXpert2 array are lost if the RAIDXpert2 disks of the array are migrated to a non RAIDXpert2 system Delete Arrays A CAUTION Deleting an array permanently destroys all data that is on the array This action cannot be undone and it is very unl
58. ert2 14 The features of RAIDXpert2 described in this user manual apply to all license levels and supported operating systems See Supported Operating Systems Table 3 describes these features Also see Table 4 for a summary of features that are available with each license level of RAIDXpert2 RAIDXpert2 Basic RAIDXpert2 Plus RAIDXpert2 VST and RAIDXpert2 VST Plus Table 3 Features of RAIDXpert2 RAIDXpert2 Feature Description Arrays general information RAIDXpert2 allows e Creating arrays of different RAID levels using the same disks e Creating different RAID level arrays on the same disk to adapt each array to the I O that it processes Creating an array from a mix of different type disks For example a RAID10 array can be created from a group of disks that contain two SATA II HDDs and two SATA SSDs NOTE The ability to create RAID10 or RAIDABLE arrays may not be available on your system Migrating an existing array to another RAID level if the type of array being used is not the optimal type for the application This function depends on the array capacity and redundancy level An array refers to data storage created by RAIDXpert2 from one or more disks Although an array can be created from several disks it is seen by the operating system as a single disk Array hiding An array can be hidden from the operating system so that neither the software nor users can see or access it Array recovery If an array
59. erve space on the disk Therefore an automatic restore is not guaranteed if a disk fails If a disk fails make space on the disk for the fail over to complete or assign a different disk with enough space If a dedicated spare is assigned and a disk fails the restore process starts automatically if there is enough space available on the dedicated spare A CAUTION Ifa disk is part of an AMD RAID array the disk cannot be selected for initialization To initialize the disk anyway delete the AMD RAID array Data on the disk is deleted during initialization so ensure the correct disks are chosen to initialize A CAUTION A legacy disk can contain valid data When a legacy array is deleted or when its corresponding legacy disk is initialized the data is lost A CAUTION When a disk is initialized all data on the disk is lost RAIDXpert2 User Guide 11 Caution Messages about Arrays 12 A CAUTION Deleting an array permanently destroys all data that is on the array This action cannot be undone and it is very unlikely the data can be recovered A CAUTION Do not delete the first array listed in the Arrays section if it is the AMD RAID bootable array Doing this deletes the operating system and AMD RAID files A CAUTION Do not initialize a disk that is part of an array Initializing a disk in a non redundant array deletes the array and its data The array no longer appears in Array View This is especi
60. esired Region and Time Zone b Ensure that the Hardware Clock Set to UTC checkbox is not selected if local time is desired c Click Next At the Server Base Scenario window a Ensure that Physical Machine default is selected b Select any other settings that are appropriate for your configuration c Click Next At the Installation Settings window Click the Overview tab Click the Software category At the Development category select the C C Compiler and Tools checkbox Click the Details button At the Filter drop down menu select Search At Search type 1ibstdC and click Search At the checkboxes that appear on the right hand section of the window ensure that the checkboxes that correspond to the 32 bit standard C shared libraries are selected and click Accept h At the YaST2 agfa fonts window click Accept i At the Changed Packages window click Continue wre Ao rp At the Installation Settings window a Click the Overview tab b Click the Partitioning category c At the Preparing Hard Disk Step 1 window select the AMD Array and click Next d At the Preparing Hard Disk Step 2 window review the text and click Next Back at the Installation Settings window e Click the Expert tab f Click the Booting category g Click the Boot Loader Installation tab h Change the setting from Boot from Boot Partition to Boot from Master Boot Record and click OK ly At the main menu of the
61. f a system has six disks and the staggered spinup count is set to 2 RAIDXpert2 sends a command to spin up disks 1 and 2 together then disks 3 and 4 and finally disks 5 and 6 1 At the Main Menu use the arrow keys to highlight Controller Options 2 Press Enter 3 4 Press Enter Use the arrow keys to highlight Set Staggered Spinup Count The number within the brackets changes color to indicate it is selected 5 Use the arrow keys to change the number within the brackets The minimum is 1 and the maximum is 8 6 7 Press Enter to save the setting Press Esc to return to the Main Menu Continue Booting from the BIOS Configuration Utility After settings have been changed continue booting the system from the point where the user entered the RAIDXpert2 BIOS Configuration Utility Resume the Boot Process 1 2 At the Main Menu use the arrow keys to highlight Continue to Boot Press Enter RAIDXpert2 User Guide 33 34 BIOS Configuration Utility 5 Software Installation This Installation Guide is designed to assist you with system setup by performing these general procedures System setup process overview A generic system setup process follows these steps 1 w ooa a o Copy the AMD RAID drivers to a removable storage medium tv IMPORTANT Install the device drivers and applications on a system at the same time that the Windows or Linux operating system is installed Power on the sys
62. g help displays help and examples regarding that specific mode and its options To view the rcadm man page on a Linux system Type man rcadm Create New Arrays rcadm create The rcadm create or rcadm C command allows new arrays to be created As many as eight arrays can be partitioned and created across all disks Portions of disks can be used to create arrays while other arrays are using different portions of the same disks A maximum of eight arrays can be created 82 rcadm Command Line Interface Tool Before you begin Creation of arrays even redundant arrays allows users immediate access to the arrays If the system reboots the creation process continues where it left off A CAUTION In some circumstances more than eight arrays are possible They might appear to function properly but are not supported Ef NOTE The array size of the new array is limited to 2 199 TB with some operating systems Refer to the operating system documentation for details on maximum array sizes NOTE The ability to create RAID10 or RAIDABLE arrays may not be available on your system Example To create a 1 GB RAIDS array using disk members 1 2 and 3 type rcadm C r5 d 1 2 3 s 1000 To see more examples type rcadm C Delete Arrays rcadm delete The rcadm delete or rcadm D command allows the user to delete one or more arrays A CAUTION Deleting an array permanently destroys all data that is on
63. ge contains all Linux variations Smp bigsmp etc fora particular release Therefore only one iso file exists NOTE Some of the windows indicated in this procedure might not appear during the installation Power on the system Insert the USB drive that contains the AMD RAID drivers into the USB port Insert the SUSE Linux operating system CD ROM or DVD into the system s CD or DVD drive Create a bootable array by following the procedure in Create Arrays on page 28 Pe hy 38 Software Installation p 10 11 12 13 14 15 At the SUSE Linux Enterprise Desktop window scroll down to Installation a At Boot Options type brokenmodules ahci oem modules 1 b At SLED 10 SP4 32 bit type brokenmodules ahci oem modules 1 irqpoll iy IMPORTANT Type in the command line within 3 to 5 seconds after the window appears c Press Enter EY NOTE It might be necessary to press F3 to change the Video Mode to VESA if no video appears on the monitor At the Language window a Select I Agree to the License Terms b Make sure that the Language and Keyboard Layout categories are set to English US or select a different language c Click Next At the Media Check window make sure that the CD or DVD Drive setting is correct and click Next At the Installation Mode window make sure that New Installation default is selected and click Next At the Clock and Time Zone window a Select the d
64. gram manage command to manage and query RAIDXpert2 arrays and Create Uses the rcadm create command to create a new array Delete Uses the rcadm delete command to delete arrays Transform Uses the rcadm transform command to transform an array supported by RAIDXpert2 Plus Follow Uses the rcadm follow command to follow or monitor arrays and disks Split Uses the rcadm split command to split mirrored arrays into separate arrays Create Copy Uses the rcadm create copy command to create a new array and then copy the specified array data to the new array of equal or greater capacity Follow these instructions to issue the command on the operating system Also see View Help from the Command Line on page 82 To Use rcadm with a Linux OS By default readm is installed in usr bin To Use rcadm with a Windows OS Change directories to 3Program Files RAIDXpert2 Run the rcadm exe command from there or Add Program Files RAIDXpert2 to the system or user path environment variables RAIDXpert2 User Guide 79 Manage Arrays and Disks rcadm manage The rcadm manage or rcadm M command allows the user to view information about RAIDXpert2 and manage the arrays and disks For example the user can Set cache attributes for arrays Set priority levels for tasks on an array Hide and unhide arrays List arrays Initializ
65. gz C opt cd opt raidxpert2 htdocs sudo cp rv raidxpert2 opt lampp htdocs To start lampp enter sudo opt lampp lampp startapache Restart Apache Enter runlevel d etc rce2 d sudo ln s opt lampp lampp S99lampp sudo ln s opt lampp lampp K01lampp Where runlevel is the default runlevel for your system NOTE This must be done after each system reboot A RAIDXpert 2 icon appears on the desktop RAIDXpert2 User Guide 43 44 Software Installation 6 AMD RAIDXpert2 Graphical User Interface GUI Start RAIDXpert2 RAIDXpert2 can be accessed using a web browser or Windows shortcut Web browser Access Browser setup Use Chrome version 20 Firefox version 14 Internet Explorer 8 or Safari 6 or a greater version of each To optimize the display use a color monitor and set its color quality to the highest setting To navigate beyond the Sign In page with a valid user account e Set the browser s local intranet security option to medium or medium low For Internet Explorer 8 adding the controller s network IP address as a trusted site can avoid access issues e Verify that the browser is set to allow cookies at least for the IP address of the controller To see the help window in Microsoft Internet Explorer you must enable pop up windows Signing in using a web browser 1 2 In the web browser s address field type the IP address of a controller network port and press
66. he Options Menu Ef NOTE Both usernames and passwords are case sensitive 4 5 At the Options menu select Password The Choose a new Username and Password window displays In the Old Password field enter the default password you used to login In the New Password field enter the new password Follow the guidelines in Things to Know About Passwords In the New Password field re enter the new password Click Submit Help and About Windows To view the software version and build number for the GUI select About at the Help menu The AMD RAIDXpert2 Driver Version and GUI Version displays 46 For customer support select Help gt User Guide A pdf version of this document will display A pdf reader will be necessary to view it For further customer support contact your system supplier or motherboard vendor AMD RAIDXpert2 Graphical User Interface GUI Reviewing the RAIDXpert2 GUI The Array View Section of the Array Status Window Elements of the Array View Section The Array View section presents a graphical view of array properties Table 15 provides information about the elements of the Array View section Table 15 Elements of the Array View section Array Status window Element Description Controller Name The RAIDXpert2 controller for the arrays displayed below it Array The number assigned to an array Array name The name assigned to an array RAID level The RAID level of the array Disk
67. he array Press Enter to include the selected disk in the array In the User Input section use the arrow keys to select RAIDABLE Press Enter Press C to confirm the array settings Alternatively press Esc to go back to a previous page or M to exit to the Main Menu Delete Arrays A CAUTION Deleting an array permanently destroys all data that is on the array This action cannot be undone and it is very unlikely the data can be recovered A CAUTION Do not delete the first array listed in the Arrays section if it is the AMD RAID bootable array Doing this deletes the operating system and AMD RAID files Delete an Array 1 2 3 At the Main Menu use the arrow keys to highlight Delete Arrays Press Enter Select the arrays to delete e To select all arrays press the A key e To select individual arrays highlight an array with the arrow keys and press Insert Any number of arrays may be selected using this method Press Enter to delete the selected arrays Press C to confirm the deletion Alternatively press Esc to exit to the Main Menu X TIP Also see Delete Arrays on page 57 Swap Arrays Use the Swap Two Arrays option to arrange arrays in a different order Before you begin 30 If more than one array is created install the operating system to any of them However a small amount of boot information is always written to a disk s in the first array Array 1 of the Array section regardles
68. her intellectual property right recognized in any country or jurisdiction in the world The Software is protected both by United States law and international treaty provisions All rights not expressly granted in this Agreement are reserved by Dot Hill and Licensors respectively 5 Term and Termination This Agreement shall continue in effect until terminated Dot Hill or AMD may terminate this Agreement immediately if You fail to comply with any provision of this Agreement Upon termination You shall discontinue use of the Software and either destroy erase or return all copies of the Software in Your possession or control 6 No Warranty THE SOFTWARE IS PROVIDED AS IS WITHOUT ANY WARRANTY OF ANY KIND EXPRESS OR IMPLIED DOT HILL AND AMD DISCLAIM ON THEIR OWN BEHALF AND ON BEHALF OF LICENSORS ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING ANY IMPLIED WARRANTIES OF NONINFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE SOFTWARE OR THAT THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR FREE OR WILL OPERATE IN COMBINATION WITH OTHER SOFTWARE OR HARDWARE Dot Hill and its Licensors will not provide support for the Software and to the extent you believe that are entitled to support you are advised to contact the party from whom you received the Software Notwithstanding the foregoing Updates to the Software which may or may not be distributed shall be governed by this Agreement and such Updates will be considere
69. ice Select Update driver software Select Browse and navigate to the storage medium Click OK Click Next If the Windows Security Pop up appears click Install or similar Click Close 8 Reboot the system mmeacse 9 After the operating system is installed remove the storage medium and Microsoft Windows OS CD ROM or DVD from the applicable drive s and port 10 Proceed to Installing the AMD RAIDXpert2 Management Suite for Microsoft Windows on page 41 Installing AMD RAID drivers while installing Linux 294 f NOTE The Linux operating system modules must include the gcc compiler and the pthreads library so that the rcadm program can be installed properly There are separate procedures in this section for each supported version of Linux e For SUSE Linux 10 x and 11 x installations see Installing the AMD RAID drivers during a SUSE Linux Enterprise Desktop SLED Installation on page 38 e For Ubuntu Linux 12 x Desktop installations see Installing the AMD RAID drivers during a Ubuntu 12 x Desktop Linux installation on page 40 Installing the AMD RAID drivers during a SUSE Linux Enterprise Desktop SLED Installation EY NOTE Prior to starting this procedure obtain the AMD RAID drivers from your system supplier or motherboard vendor Copy the AMD RAID drivers to a USB flash drive following the instructions in Copying AMD RAID drivers in a Linux environment on page 35 f NOTE The SUSE driver CD ROM iso ima
70. ikely the data can be recovered RAIDXpert2 User Guide 57 Before you begin Review the issues and recommendations indicated in Table 23 Table 23 Deleting arrays Issues and recommendations Issue Recommendation Drive letters or partitions Remove drive letters or partitions from the array using procedures in your operating system Each operating system has different names and paths for removing drive letters or partitions and as such are outside the scope of this document For more information see your operating system s user documentation Operating system impact on arrays Delete an array If the array is not being used by the operating system the array can be deleted at any time even while tasks are running on the array If the array is being used by the operating system the array cannot be deleted Therefore a RAIDXpert2 bootable array cannot be deleted in RAIDXpert2 A RAIDXpert2 bootable array can only be deleted in the BIOS Configuration Utility 1 Inthe Array Status window select the array to deleted 2 At the Array menu select Delete A Delete window displays with a warning about deleting the array 3 Click OK 4 The array disappears from the Array View section X TIP Also see Delete Arrays on page 30 Recreate a deleted array If an array is deleted it might be possible to recreate the array See Table 37 on page 72 Change Cache Settings for Arrays Table 24 provi
71. in page does not display verify that you have used the correct shortcut Select a language at the drop down menu RAIDXpert2 User Guide 45 3 On the Login page enter the name and password of a configured user The default user name and password are admin and admin amp NOTE Both usernames and passwords are case sensitive 4 Click Submit If the system is available the RAIDXpert2 GUI page is displayed otherwise a message indicates that the system is unavailable Password Protection When the system displays a window that prompts you to choose a username and password use the procedure below 1 Inthe Username field enter the new username 2 Inthe Password field enter the new password Follow the guidelines in Things to Know About Passwords 3 Inthe Confirm New Password field re enter the new password NOTE Both usernames and passwords are case sensitive 4 Click Submit Things to Know About Passwords RAIDXpert2 cannot be opened without a password Create a password that is easily remembered The password must be 4 20 characters long The password is case sensitive The application does not track previous passwords unless enabled through your web browser To change an existing password see Change a Password at the Options Menu on page 46 If a user forgets the username or password delete rc_login txt to restore the default user name and password admin and admin Change a Password at t
72. ined with array types like RAIDO RAIDS RAID6 or RAID10 RAID Reliability Considerations RAID reliability is enhanced through data redundancy and backup Data Redundancy RAID1 RAIDS RAID6 or RAID 10 are necessary for redundancy With redundancy both capacity and performance are sacrificed for reliability With RAIDXpert2 extremely high performance is obtained even with redundant type arrays Backup The ability of RAIDXpert2 to transform arrays can be used as part of a backup strategy As part of a hot fallback strategy the backup array can be kept online and hidden from the operating system or remain visible or it can be removed from the system and stored as a backup device 2994 NOTE The Transform task is supported by RAIDXpert2 Plus Flexibility and Expansion Considerations Before configuring an array consider the following points to enhance the flexibility of the RAID system Multiple RAID Levels With RAIDXpert2 different RAID levels can be created on the same disk to adapt each array to the I O that it processes Also more than one array can be created per disk Depending on the array capacity and redundancy level an existing array can be transformed to another RAID level if the level of the array being used is not the optimal RAID level for the application Also different arrays with different characteristics can be built for different applications RAIDXpert2 User Guide 25 RAIDABLE Arra
73. ing Disks on page 73 e Configuration Utility or is offline A disk is highlighted red at the BIOS The disk has failed Configuration Utility Depending on the RAID level of the array data might be lost RAIDXpert2 cannot communicate with The dedicated spare is not visible in the the spare BIOS Configuration Utility or is offline The disk cannot be initialized Only disks that are Ready can be Ensure the disk is not already a initialized member of an array Ensure the disk is still assigned as a A CAUTION Whena disk is global or dedicated spare initialized all data on the disk is lost Ensure the disk is reporting a Ready state 72 Troubleshooting Troubleshooting Disks Perform the following actions when there may be a problem with a disk e Ensure there is no damage to the system s backplane e Ensure all cables are installed correctly e Ensure the disk is seated correctly in the backplane or bay and the latch is secured e Reinsert the disk e Replace the disk e After reconnecting reseating reinserting or replacing a disk e Perform a rescan e Initialize the disk A CAUTION When a disk is initialized all data on the disk is lost If problems with a disk have caused an array to go Critical it may be necessary to also assign a dedicated or global spare for the array If problems with a disk have caused an array to go Offline data may have been lost Recover lost data from a backup storag
74. ing the size e Press Enter when either the desired size or the maximum available size is reached 8 Select a caching level using the arrow keys 9 Press Enter 10 Press C to confirm the array settings Alternatively press Esc to go back to a previous page or M to exit to the Main Menu 11 Repeat step 3 through step 10 to create additional arrays When installing the operating system to an AMD RAID bootable array modify the boot priority list in the motherboard BIOS See the motherboard s user documentation for more information Ensure that the AMD RAID bootable array is included in the boot priority list Ensure that INT13 support is enabled on the RAID controller as described in Change the Controller Options on page 32 Create an AMD RAID Bootable Array A CAUTION Do not use eSATA drives for bootable arrays as they are removable The operating system and RAIDXpert2 files can be installed to a RAIDXpert2 bootable array Use the Create An Array procedure above to create the bootable array Ensure it is the first array listed in the Arrays section of the BIOS Configuration Utility To install the operating system and RAIDXpert 2 files see Software Installation RAIDXpert2 User Guide 29 Create a RAIDABLE Array NOTE The ability to create RAIDABLE arrays may not be available on your system SA SN OS At the Main Menu use the arrow keys to highlight Create Array Press Enter Select the disk with which to create t
75. ion be disabled only if the system is booted from another device 1 MoR Se NY At the Main Menu use the arrow keys to highlight Controller Options Press Enter Use the arrow keys to highlight Toggle INT13 Boot Support Press Enter to toggle between On and Off Press Esc to return to the Main Menu Pausing the boot sequence for warning messages When the Pause feature is enabled and an array goes critical offline or there is another problem with the system the boot process stops and an error message is displayed on the screen The user must press Enter to continue booting If the Pause feature is disabled error messages are displayed briefly but the system continues to boot 1 2 3 5 At the Main Menu use the arrow keys to highlight Controller Options Press Enter Set pauses to the boot sequence for critical warnings a Use the arrow keys to highlight Toggle Pause if Critical b Press Enter to toggle between On and Off e On enables pauses e Off disables pauses Set pauses to the boot sequence for offline warnings a Use the arrow keys to highlight Toggle Pause if Offline b Press Enter to toggle between On and Off e On enables pauses e Off disables pauses Press Esc to return to the Main Menu Change the Staggered Spinup Count Depending on a system s power supply load rating the end user might want to limit the number of disks that are spun up together when a system is powered on For example i
76. is accidentally deleted it might be recovered by creating a new array with the same properties as the deleted array This can occur only if disk Write Access operations are not in progress Background array initialization The background initialization of a redundant array creates the redundant BGD data that allows the array to survive a disk failure Background initialization allows a redundant array to be used immediately Data is not lost if a disk goes offline prior to completion of the BGI process Cache support for arrays Various array caching options are supported No Cache Read Cache Write Back Cache Read Write Back Cache Cache support for disks Various disk caching options are supported No Cache Disk Read Ahead Cache Disk Write Back Cache Disk Read Ahead Write Back Cache Secure Erase All data on an array can be erased and ensured it is unrecoverable even with advanced data recovery techniques Consistency Check A Consistency Check is a background operation that verifies and corrects the mirror or parity data for fault tolerant disks It is recommended that a Consistency Check be run periodically on an array Consistency Check automatically corrects mirror or parity inconsistencies A Consistency Check can be scheduled or started manually by the system user Getting Started Table 3 Features of RAIDXpert2 continued RAIDXpert2 Feature Description Disk roaming With disk roaming SA
77. istributor Subject to the terms and conditions of this Agreement you are granted a limited non exclusive non transferable non sublicensable license to distribute and or install the Software in its unaltered object code form solely i to and on behalf of a purchasing End User for the End User s internal business purposes and ii only for use with one 1 AMD product purchased through authorized AMD sales channels Except as specifically stated in this Section 1 Authorized Distributors are expressly prohibited from copying and or distributing the Software in whole or in part using the Software to provide consulting or other services to third parties and distributing the Software in any form or format Authorized Distributors are subject to all other terms and conditions of this Agreement Authorized Distributors must ensure that its End Users see and agree to this Agreement 2 Limited License to End Users If you have licensed the Software for your own personal use or your company s internal use you are an End User You are hereby granted subject to the terms and conditions of this Agreement a limited non exclusive non transferable non sublicensable license to use this Software in its unaltered object code form solely i for internal business purposes and ii only with respect to one 1 AMD product that was purchased through authorized AMD sales channels Further you must obtain this Software only from authorized AMD sales cha
78. ive Command Queuing is a command protocol of disks that are supported by RAIDXpert2 NCQ enables individual disks to internally optimize the order in which Read and Write commands are executed RAIDXpert2 permits a queue depth of up to 32 read write commands per disk Online Capacity Expansion OCE OCE is a process that allows the user to add storage capacity to an existing array without taking the system offline OCE enables the user to increase the total storage capacity of an array by integrating unused storage into the array Data can be accessed while the disks are added and while data on the array is being redistributed NOTE This feature is not available with all license levels See Table 4 RAIDXpert2 User Guide 15 Table 3 Features of RAIDXpert2 continued RAIDXpert2 Feature Description Online RAID Level Migration With online RAID level migration users can easily move an array from ORLM one RAID level to another While the migration is taking place data is accessible and protected to the lowest protection of either the source RAID level or the destination RAID level EY NOTE This feature is not available with all license levels See Table 4 RAID Level Support RAIDXpert2 supports RAID levels 0 1 5 6 10 Volume and RAIDABLE EYNOTE RAIDS RAID6 and RAIDABLE are not supported by all license levels See Table 4 NOTE The ability to create RAID10 or RAIDABLE arrays may not be
79. l Information Corrective Actions One or more disks in the array Due to the failed disk or disks the array is no longer See Troubleshooting Disks on have failed or been removed maintaining redundant mirrored or parity data page 73 The failure of an additional disk results in an Offline state and lost data RAIDXpert2 User Guide 69 Table 33 An array is in an Offline state Possible Causes Additional Information Corrective Actions The array has lost the One or more disks have failed See Troubleshooting Disks on page 73 maximum allowable disks per e If the array is non redundant the failure of a single disk RAID level causes the array to fail If the array is redundant the failure of two or more disks causes the array to fail The array cannot be restored rebuilt Table 34 Cannot assign a dedicated spare to an array Possible Causes Additional Information Corrective Actions The RAID level does not Dedicated spares cannot be created for e Create an array with a different RAID allow dedicated spares Volume or RAIDO arrays level and assign a dedicated spare e Create a global spare The designated disk does not The capacity of the disk selected to be a Select a different disk have sufficient capacity to be dedicated spare must be equal to or larger a dedicated spare than the capacity of the smallest disk in the array Table 35 Cannot create a global spare Possible Causes Additional Information Cor
80. ll data on the disk is lost Linux Free open source UNIX based operating system OCE Online Capacity A feature available with a RAIDXpert2 Plus license that allows users to add up to 12 disks to an Expansion array at any time and continue to access data while it is being redistributed ORLM Online RAID A feature available with a RAIDXpert2 Plus license that allows users to move from one RAID Level Migration level to another While the migration is taking place data is accessible and protected to the lowest protection of either the source RAID level or the destination RAID level RAIDXpert2 User Guide 85 86 Index A About and Help windows 46 application workload 25 array details viewing 32 list elements for readm 81 rcadm list elements 81 viewing details 32 Array Status window Array List section 48 Array View section 47 Disk List section 47 Event View section 49 Array View section Array Status window 47 arrays array states 20 assessing additional space 56 cache setting changing 58 cannot create an array 69 checking consistency 59 commands at RAIDXpert2 49 continue booting from the BIOS Configuration Utility 33 create and format 52 create from the BIOS Configuration Utility 29 creating 52 delete 57 deleted array how to recreate 58 expansion future 21 formatting 52 migration 57 naming 54 partitioning 54 partitioning and formatting 54 physical removal preparation 57 rebuilding restoring a C
81. lusions or limitations may not apply to You In that event to the extent permissible any exclusion of warranties or limitation of liability will be limited in duration or type to the greatest extent allowed by law 8 Export Controls You agree to comply fully with all relevant export laws regulations treaties and orders Export Laws to assure that neither the Software nor any components thereof are i exported directly or indirectly in violation of Export Laws or ii are intended to be used or are used for any purposes prohibited by the Export Laws 76 Software License EULA 9 General This Agreement and any disputes arising from or relating to it shall be governed by and construed in accordance with the laws of the State of Colorado without reference to conflict of laws principles and excluding the U N Convention on Contracts for the International Sale of Goods Any legal action or proceeding shall be instituted in a state or federal court in Denver Colorado U S A and You agree to be subject to the jurisdiction of these courts Taxes and charges imposed by any government with respect to the Software shall be paid by the End User The waiver by either party of a breach of this Agreement or a failure to exercise any right hereunder shall not operate or be construed as a waiver of any subsequent breach or as a waiver of any other right If any provision of this Agreement is held to be unenforceable or overbroad for any reason it will
82. ndow Manually start a Consistency Check 1 Inthe Array View section select the array on which to run the Consistency Check 2 At the Array menu select Check Consistency 3 Click Start Manually stop a Consistency Check 1 Inthe Array View section select the array on which to stop the Consistency Check 2 At the Array menu select Check Consistency 3 Click Stop Schedule a Consistency Check A Consistency Check task can be scheduled for later in the day or week A Consistency Check task can be scheduled to run each week or each month NOTE Schedule only one Consistency Check event on an array This means that if a monthly check has been scheduled and a weekly check is desired delete the monthly event and schedule the new event Table 25 provides information on the available scheduling options for a Consistency Check Table 25 Consistency Check options Option Description One Time Only Schedule the Consistency Check for the current day Today or up to seven days in the future Weekly Events can be scheduled weekly After it is selected a Consistency Check runs on the specified array at the same time each week Monthly Events can be scheduled to run once per month to run on the specified array at a specified time Schedule a Consistency Check for later 1 Inthe Array View section select the array on which to run the Consistency Check 2 At the Array menu select Check Consistency 3
83. ne by using a rescan A rescan also stops and then automatically resumes all tasks To rescan disks select Rescan at the Disk menu Change Cache Properties for Disks The Read Ahead and Write Back Cache properties can be changed if the disks support this option The default settings are e Read Ahead enabled e Write Back Cache enabled A CAUTION Leaving Write Back Cache enabled can increase the likelihood of data being corrupted if the system experiences a power interruption or unexpected shutdown NOTE A disk s cache setting cannot be changed if a task is active for the array The cache settings are enabled when the task is finished Change disk caching properties 1 At the Disk menu select Properties The Properties window displays 2 Select the disks 3 Click Enable or Disable for the desired settings NOTE Each time Enable or Disable is clicked the disk selection clears To change multiple settings on one disk select the disk before clicking each setting Assign Spares Spare disks allow an array to be rebuilt when a disk fails Global spares can be used in any array while dedicated spares are assigned to a specific array Assign a disk as a dedicated or global spare 1 Inthe Disk List section select a disk 2 At the Disk menu select Spare Identify Options for Disk Device displays in the Disk List panel RAIDXpert2 User Guide 51 3 Perform one of the following actions e To use th
84. ne state cannot be restored This means that non redundant arrays Volume RAIDO cannot be restored when a single disk in a non redundant array fails the array state changes to Offline EY NOTE Ifa Critical redundant array that is being restored loses a second disk RAID1 or RAIDS or loses a second disk in the same mirror set RAID10 or the third disk of a RAID6 array the Restore task fails The array must be re created from backup storage data AMD RAIDXpert2 Graphical User Interface GUI Before you begin Make sure that the disk chosen as the dedicated spare or global spare has sufficient available capacity to restore the array The capacity of the spare disk must be equal to or larger than the capacity of the smallest disk in the critical array Know how to create a global or dedicated spare See Add or Remove Dedicated Spares on page 61 or Add or Remove Global Spares on page 61 Restore a Critical array 1 2 3 5 In the Array View section select the critical array At the Disk List section select a disk At the Disk menu select Spare Identify Options for Disk Device displays in the Disk List panel Perform one of the following actions e To use the disk as a dedicated spare select Assign as Dedicated Spare e To use the disk as a global spare select Assign as Global Spare Click Confirm Prepare to Physically Remove an Array Physically remove an array A CAUTION Prior to removing an array r
85. ng or removing disks disks can be added or removed while the system is online hot swapping if the system supports the hot swapping function Because of this function RAIDXpert2 does not automatically perform a rescan when it detects that a disk has been added or removed For example to hot swap a RAIDS set with six disks into a new system do not perform a rescan until all six disks have been connected Arrays associated with the disks that are not yet connected change state to either Critical or Offline In the example above if the state of the RAIDS set changes to Offline data is lost Rescanning can also result in the state of a disk being reported differently in the Array View and the Disk List A disk within an array can have a state of Failed in the Array View field while at the same time it can show a state of Online in the Disk List RAIDXpert2 User Guide 23 Sparing Options Disks and Arrays RAIDXpert2 supports multiple sparing options Spares are restored in the order indicated in Table 11 Table 11 Sparing options Fa Dedicated A spare disk assigned to a specific redundant array Global A spare disk that is shared by multiple arrays NOTE An array is marked Critical or Offline if a disk reports a Failed state to an I O or if the SATA cable or power cable is disconnected 2994 NOTE One or more spares can be assigned to a redundant RAID level f NOTE Spare assignments do not
86. nnels Obtaining it from any other source is a violation of the intellectual property rights of AMD and its licensors 3 Restrictions Except as expressly authorized in Sections 1 and 2 above Authorized Distributors and End Users collectively You shall not nor cause or permit any other person to i reverse engineer translate disassemble derive source code from decompile rent lease manufacture adapt create derivative works from or otherwise modify or distribute the Software or any part thereof ii copy in whole or in part the Software with the exception that only End Users may make one copy of the Software for their backup or archival purposes iii publicly display the Software or use the Software to provide consulting or other services to third parties or iv delete any copyright trademark patent or other notices of proprietary rights as they appear anywhere in or on the Software RAIDXpert2 User Guide 75 4 Proprietary Rights The Software is primarily the intellectual property of Dot Hill Systems Corp Dot Hill and its licensors Licensors In no event shall You obtain title to the Software or any component thereof As between Dot Hill and You Dot Hill has all rights title interest ownership and proprietary rights in and to the Software Dot Hill s rights include but are not limited to all copies of the Software and any patent rights copyrights trademark rights trade secret rights and any ot
87. pears as Missing in the Array View for the arrays to which it belonged e A disk that experiences a catastrophic failure appears in the Disk List as Offline and is highlighted in red The disk appears as Failed for the arrays to which it belonged e A disk that has a SMART error appears in the Disk List as SMART Error A disk with a SMART error can be used to create an array but the array must be created in the BIOS Configuration Utility not in RAIDXpert2 e A disk that experiences a software related failure appears in the Disk List as Online and is highlighted in red New arrays can be created with the disk Arrays that exist on a failed or disconnected disk might not be designated as Failed or Missing until the system attempts to communicate with the failed or disconnected disk Rescanning Disks for Changes in State The information displayed in the Disk List section is the state of the disks when they were last scanned If a rescan has not been performed the information being displayed is the state of the disks at boot time Every time a disk is connected or disconnected while online a message asks if the user wants to perform a rescan of all SATA channels If Rescan is selected the information in both the Array List and the Disk List is updated This view might show arrays as being in a Critical or Offline state if all disks have not been installed or removed Although it is highly recommended that the system be shut down before addi
88. ray numbers are valid only for a given boot and can be different in the BIOS Configuration Utility and RAIDXpert2 If a permanent label is required use the Array Naming feature described in Name Arrays on page 54 Array size The array size of the new array is limited to 2 199 TB on some versions of Windows and Linux Refer to the operating system documentation for details on maximum array Sizes Number of arrays In some circumstances more than eight arrays are possible They might appear to function properly but are not supported by AMD RAID System reboot When the system reboots the creation process continues where it left off Create an array Select an array and cache 1 2 At the Array menu select Create Select the disk s to include in the array by checking the box next to the desired disk s in the Select Active Disks field NOTE Click All to select all disks or click Unused to select disks that are not currently used in an array Enter a name for the array in the Array Name field EY NOTE The following characters are not allowed in an array name gt 4 Pe Select an array type at the Array Type drop down menu At the Organized As drop down menu select an option NOTE The Organized As drop down menu only displays options for advanced management of RAID10 and RAIDS0 configurations if you selected a RAID10 or RAIDS0 Enter the capacity in the Capacity field
89. rective Actions The disk is already part of an A global spare cannot be selected if it is Select a different disk array already part of an existing array There are no empty disks A disk with a legacy state can be initialized if e Install additional disks available or the disks have not desired but it is no longer legacy e Initialize the disks been initialized initialization adds RAIDXpert2 configuration information to the disk A CAUTION When a disk is initialized all data on the disk is lost The disk assigned as the See Troubleshooting Disks on page 73 global spare has failed or is missing 70 Troubleshooting Table 36 Cannot create an array larger than 2 199 TB Possible Causes Additional Information Corrective Actions Using an incorrect procedure There is a limit of 2 199 TB Create a smaller array to create an array larger than per array in the Windows Create an array on 32 or 64 bit Windows XP using the 2 199 TB with 32 or 64 bit architecture Arrays larger following procedure Windows XP than this do not operate properly 1 Determine how many arrays are needed a Divide the desired array size by 2 199 TB Round down to the nearest whole number The resulting number is the number of maximum sized arrays Microsoft Windows addresses this problem with dynamic disks Disks greater than 2 199 TB can be created from needs groups of smaller arrays Example through the use of dynamic Desired arr
90. ritical array 56 recreating a deleted array 72 restoring rebuilding a Critical array 56 scanning in the background 61 sparing options 24 tasks starting and stopping 22 tasks starting and stopping 21 transform using readm 83 transforming 54 understanding their purpose 19 Arrays Status section Array Status window 48 audience intended 9 who should use this user manual 13 B backup strategy 25 BIOS Configuration Utility access 27 arrays creation of 29 arrays deletion of 30 arrays swapping 30 arrays viewing details 32 color codes 27 continue booting 33 controller options 32 disks initialization of 28 disks viewing details 31 32 rescan all channels 32 spinup count changing 33 when to use 27 C cache attributes 25 cache settings changing 58 changing for disks 51 color codes BIOS Configuration Utility 27 commands RAIDXpert2 array and disk 49 consistency checks arrays 59 scheduling 60 controller list elements using readm 80 controller options changing 32 conventions document 9 create task arrays 52 D data redundancy 25 dedicated spares adding 61 removing 61 dedicated sparing 24 delete arrays BIOS Configuration Utility 30 how to recreate 58 how to recreate it 72 using readm 83 Disk List section Array Status window 47 disks capacity online expanding OCE 21 changing cache settings 51 commands at RAIDXpert2 49 details BIOS Configuration Utility 31 32 disk states 22 initializa
91. rom the Disk List the most likely cause is e A loose cable Make sure that all disk cables are connected then perform a rescan e A disk that is not fully seated in its bay or slot Make sure that the disk is inserted completely in its bay or slot then perform a rescan For more information see Rescan Disks on page 51 The Array List Section of the Array Status Window Elements of the Array List Section The Array List section provides information about the arrays Table 17 provides information about the elements of the Array List section Table 17 Elements of the Array List section Array Status window Element Description Device The array number Partition Drive letter that was assigned to this array during the partition process A blank space appears if the array has not been partitioned EY NOTE If a dynamic volume is created on an array RAIDXpert2 cannot retrieve the volume s drive letter Array Name User created name for the array Type The RAID level RAID type or LEGACY Total Capacity Total capacity 1 MB 1 000 000 bytes 1 GB 1 000 000 000 bytes NOTE Because the ATA storage industry has standardized the meanings of MB as 1 000 000 bytes and GB as 1 000 000 000 bytes RAIDXpert2 reports the same units State of the array NORMAL CRITICAL OFFLINE Task type if in progress TRANSFORM CHECK CHECK_BITMAP CREATE RESTORE ZERO SECURE_ERASE Task State The state of the t
92. rs from the web site to the appropriate removable storage medium Copying AMD RAID drivers in a Linux environment 1 2 Power on the system Locate and use a system that is running a Windows operating system and has a USB I O port for the USB flash drive Use a browser to access the web site of your system supplier or motherboard vendor Insert a USB flash drive into the USB I O port of the system RAIDXpert2 User Guide 35 Download the AMD RAID drivers for the correct distribution version of Linux Copy the drivers onto the USB flash drive For SUSE Linux Copy the files contained inside the applicable dd rcraid SLES1x 2 6 xx xx folder to the USB flash drive The following files should be located on the USB flash drive for a SUSE Linux Enterprise Desktop SLED installation For example e linux folder e common_shell e install LICENSE e Uninstall For Ubuntu Linux Copy the files contained inside the dd rcraid Ubuntul12 3 w x yz folder into a dd directory located on a USB flash drive For an Ubuntu Linux Desktop Server installation the following files should be located in the dd directory located on the USB flash drive root For example e dd e load_raidcore e post_install e post_install2 e pre_install e xrecraid ko e rceraid_generic ko e readme Pre installation steps You can choose to boot from the platform BIOS Basic Input Output System or from UEFI UEFI is a recent industry to standardize boot proced
93. rted browsers and configurations RAIDXpert2 User Guide 41 Installing the AMD RAIDXpert2 Management Suite for Linux Obtain the AMD RAIDXpert2 Management Suite executable file Setup sh from your system supplier or motherboard vendor Download the Setup sh file to the system s desktop Table 14 Linux procedure for installing the Management Suite Element Action Ubuntu only For Ubuntu 32 bit OS enter the following commands before executing Setup sh e sudo In s 1ib i386 linux gnu libc so 6 lib libc so 6 e sudo apt get install libstdc 5 For Ubuntu 64 bit OS enter the following commands before executing Setup sh e sudo in s lib x86_64 linux gnu libc so 6 lib libc so 6 sudo apt get install ia32 libs NOTE Ifentering sudo apt get install fails enter sudo apt get update first and ensure your SUT can access the Internet Verify that the Setup sh file is executable by right clicking on the Setup sh file on the system s desktop b From the pop up menu select the Properties category Click the Permissions tab Permissions tab Ensure that the Execute or Executable checkbox es is are selected Click Close Setup sh icon Double click the Setup sh icon that is on the desktop At Do you want to run Setup sh or display its contents click Run c Wait while Linux runs the Management Suite installer Introduction window Click Next License Agreement
94. s on which array the operating system is installed If anything happens to a disk in Array 1 the system might not be able to boot It is recommended that the user install the operating system on an AMD RAID bootable array at a redundant RAID level such as RAID1 or RAID5 and swap the array into the first position if it is not already Array 1 Swapping arrays can be performed only at the BIOS Configuration Utility BIOS Configuration Utility Swap Arrays 1 2 3 4 At the Main Menu use the arrow keys to highlight Swap Two Arrays Press Enter Select the arrays to swap a Highlight an array using the arrow keys b Press Insert to select it c Highlight a different array using the arrow keys d Press Insert to select it Press Enter to swap the arrays Manage Spares This option allows the user to assign or unassign global or dedicated spares Assign Global Spares Sie Oe ee 6 At the Main Menu use the arrow keys to highlight Manage Host Spare s Press Enter Use the arrow keys to highlight Assign Global Hot Spare s Press Enter Select the disks to assign as global spares e To select all disks press the A key e To select individual disks highlight a disk with the arrow keys and press Insert Any number of disks may be selected using this method Press Enter to assign the selected disks as global spares Assign Dedicated Spares SE Ee Nr At the Main Menu use the arrow keys to highligh
95. s the correct choice for a RAID level RAID6 stripe with parity Stripes data as well as dual parity across all disks in the array Dual parity information is interspersed across the disk array In the event of failure of 1 or 2 drives RAIDXpert2 can restore the lost of the failed disk s from the other surviving disks Supports 4 12 disks Offers exceptional redundancy as it is able to recover from 2 disk failures Offers improved read performance For use in systems with a large number of disks for which data redundancy is important RAID 10 striped RAID 1 sets Combines mirrors and stripe sets RAID10 allows multiple disk failures up to failure in each mirror that has been striped Supports 4 disks Offers better performance than a simple mirror because of the extra disks Requires twice the disk space of RAID 1 to offer redundancy RAIDXpert2 User Guide 19 Table 5 RAID levels general characteristics continued RAID Level Main Characteristic Use Usefulness Volume JBOD RAIDXpert2 treats one or more disks Provides the ability to link together or the unused space on a disk as a storage from one or several disks single array regardless of the size of the space on Supports 1 8 disks those disks Useful in scavenging space on disks unused by other disks in the array Does not provide performance benefits or data redundancy Disk failure will result in data loss RAIDABLE Allo
96. single disk fails in each mirrored set the redundant array goes to a Critical state but data is not lost If two disks fail in one of the mirrored sets the redundant array goes to an Offline state and data is lost A bootable array that is in an Offline state prevents the operating system from booting This warning message appears when Toggle INT13 Boot Support option has been set to OFF at the BIOS Configuration Utility and another boot device is not selected Bootable devices do not function with the controller when Toggle INT13 Boot Support is set to OFF The default setting is ON which allows bootable devices to function with the controller See Troubleshooting Disks on page 73 See Troubleshooting Disks on page 73 If after performing a rescan the state remains Offline the bootable array has suffered an unrecoverable failure e Create a new bootable array e Reinstall the operating system and drivers Restart the system 2 Enter the system s BIOS screen Select Main Menu gt Controller Options gt Toggle INT13 Boot Support Change Toggle INT13 Boot Support from OFF to ON Navigate to Main Menu Select Continue to Boot The system boot process continues to the operating system Array Related Errors e Cannot create an array on page 69 e An array is in an Offline state on page 70 e An array is in a Critical state on page 69 e Cannot assign a dedicated spare to an array on page 70
97. t Manage Host Spare s Press Enter Use the arrow keys to highlight Assign Dedicated Hot Spare s Press Enter Use the arrow keys to highlight the array Press Enter Select the disks to assign as dedicated spares e To select all disks press the A key e To select individual disks use the arrow keys to highlight the disk and press Insert to select it Any number of disks may be selected using this method Press Enter Press C to continue Alternatively press Esc to exit to the Main Menu Unassign Spares 1 OBR NS At the Main Menu use the arrow keys to highlight Manage Host Spare s Press Enter Use the arrow keys to highlight Unassign Hot Spare s Press Enter Select the disks to unassign as spares e To select all disks press the A key e To select individual disks use the arrow keys to highlight the disk and press Insert to select it Any number of disks may be selected using this method RAIDXpert2 User Guide 31 6 Press Enter to unassign the selected disks 7 Press C to continue Alternatively press Esc to exit to the Main Menu View Disk Details This option allows the user to view details about the disk Nothing can be changed using this menu option it is for informational purposes only 1 At the Main Menu use the arrow keys to highlight View Disk Details 2 Press Enter 3 Use the arrow keys to highlight a disk Information about the disk is displayed in the Information field across
98. t conventions Convention Element Navy blue text Figure 1 Cross reference links and e mail addresses Navy blue underlined text Web site addresses http www example com Bold font Key names Text typed into a GUI element such as into a box GUI elements that are clicked or selected such as menu and list items buttons and check boxes Italics font Text emphasis Monospace font File and directory names System output Code Text typed at the command line Monospace italic font e Code variables e Command line variables Monospace bold font Emphasis of file and directory names system output code and text typed at the command line Customer Support For customer support contact your system supplier or motherboard vendor RAIDXpert2 User Guide 9 1 Safety Precautions General This section includes general safety precautions and specific RAIDXpert2 cautions Read and keep this user manual for future reference Safety Definitions A CAUTION Indicates that failure to follow directions could result in damage to equipment or data IMPORTANT Provides clarifying information or specific instructions f NOTE Provides additional information X TIP Provides helpful hints and shortcuts Caution Messages This section lists the Caution messages that appear in the book Caution Messages about Disks A CAUTION Assigning a dedicated spare does not res
99. t the Array menu select Unlink 62 AMD RAIDXpert2 Graphical User Interface GUI Secure Erase Secure Erase is used for erasing all data on an array and ensuring that it will be unrecoverable even with advanced data recovery techniques Data is securely erased by e Hiding the array from the OS e Writing over each region of the disk with 3 patterns OxAA 0x55 and random e Using a4 pass with all zeros to ensure that a RAID1 5 6 or 10 will be consistent After the secure erase is complete a user can choose to manually delete the array or reuse it If the user chooses to reuse it it must be unhidden using the procedure in Hide an Array on page 62 A CAUTION When an array is securely erased the data on the array is lost Securely erasing an array 1 Inthe Array View section select the array to erase 2 At the Array menu select Secure Erase Working with Views The View menu allows the user to e Display the event view e Display the event log e Refresh the display Display or hide Controller Event Log panel To display or hide the Controller Event Log select Event View at the View menu When the Controller Event Log panel displays a checkmark appears next to the Event View option at the View menu Log Window The system name View Log window displays all of the messages generated by RAIDXpert2 All messages are logged not just the ones enabled at Options gt Notification All messages received from
100. tem Access the platform BIOS setup for the system For supported AMD chipsets set the SATA mode as RAID This enables the loading of the AMD RAID Option ROM Initialize the disks using the AMD RAID Array Configuration Utility Create arrays using the AMD RAID Array Configuration Utility Install the AMD RAID drivers on the system Load the operating system Install the OS RAID Management Suite AMD RAIDXpert2 on the system 2994 NOTE To protect your data always perform a backup prior to installing any new major hardware or software Before you begin Have the Windows or Linux operating system software available and ready to install Copying AMD RAID drivers to removable storage You need to copy the drivers to a removable storage medium before you begin the installation Copying AMD RAID drivers in a Microsoft Windows environment 1 2 5 Power on the system Locate and use a system that is running a Windows operating system and has a CD DVD drive floppy disk drive or an I O port for removable storage media such as a USB flash drive Go to a browser and access the web site of your system supplier or motherboard vendor Insert the storage medium into the system e For Windows XP insert a floppy disk into the disk drive e For Windows Vista Windows 7 or Windows 8 connect a USB flash drive to a USB I O port or insert a blank CD DVD disk into the applicable drive Download the AMD RAID drive
101. tem support Z zZ z Between systems support RAIDXpert2 Web GUI management GUI rcadm management CLUI Drive interfaces supported RAIDXpert2 User Guide 17 Table 4 Feature set for RAIDXpert2 by RAIDXpert2 license level continued Sub Features RAIDXpert2 RAIDXpert2 RAIDXpert2 RAIDXpert2 i VST Plus Dissimilar disk support Yes within the same array Read Cache Yes Write Back Cache Yes Read with Write Back Yes Create Array and Delete Yes Array functions without rebooting Multiple RAID levels per disk a At the AMD BIOS Configuration Utility also referred to as the Option ROM or O ROM arrays can be created or deleted and Critical or Offline arrays are indicated INT13 support can be turned off completely at the BIOS Configuration Utility b See Arrays Disks and RAID Levels for detailed information about understanding arrays RAID levels and performance and reliability considerations c The unique ability of RAIDXpert2 to provide online expansion to RAID levels across multiple disks becomes extremely valuable when expanded storage is a requirement d Disk roaming allows arrays to be moved from port to port either within the same system or between systems e See the system s motherboard specifications for the supported device interface f Multiple RAID levels array types per disk allows the administrator to create different RAID levels on the same disks For example The administrator
102. the array This action cannot be undone and it is very unlikely the data can be recovered Before you begin e Ifthe operating system is using an array it cannot be deleted e Ifan array is accidentally deleted and the user wants to try and recover the data create an array using the same disks same size and same cache and use the leave existing data option This option writes new configuration information to the array while trying to use the exact same disk space as before Example To delete array 1 type rcadm D a 1 To see more examples type rcadm D Transform Arrays rcadm transform Supported by RAIDXpert2 Plus The rcadm transform or rcadm T command allows the user to transform migrate an array from one RAID level to almost any other RAID level and to expand the array dynamically even under I O load Before you begin e An array cannot be transformed to a smaller sized array New arrays must be either the same capacity or larger e When using the task control option a Transform can only be paused or resumed but not removed e Ifa spare has been assigned to the destination array a fail over task starts as soon as the Transform completes provided the spare is available after the Transform e If there are multiple arrays on a single controller it might not be possible to transform some of the arrays to a larger size If the size of an array might be expanded in the future it is best to configure
103. the top e Unique Disk ID e Drive Type e Cache Settings e Maximum Free Space e Model Number e Serial Number 4 Press Esc to exit to the Main Menu View Array Details This option allows the details of the array to be viewed Nothing can be changed using this menu option it is for informational purposes only 1 At the Main Menu use the arrow keys to highlight View Array Details 2 Press Enter 3 Use the arrow keys to choose an array 4 The full details of the array are displayed in the Information field across the top e Array number e RAID level e Size e State e Cache settings NOTE The disks in the array are selected green Rescan All Channels This option allows the user to rescan all channels to detect new or removed disks and arrays It rereads the configuration information from each disk Sometimes when a disk is offline it can be brought online through a rescan 1 At the Main Menu use the arrow keys to highlight Rescan All Channels 2 Press Enter The activity indicator in the Information field spins while the disks are being polled ey Change the Controller Options Controller Options allows the user to configure options for the boot sequence amp NOTE By default all options are On It is recommended that options remain On 32 BIOS Configuration Utility Booting the system from an array This option allows the user to enable boot support It is recommended that this opt
104. tion 50 legacy and new 52 legacy using them 52 list elements for rcadm 80 number and organization 25 rcadm list elements 80 rescanning 51 rescanning for changes in state 23 RAIDXpert2 User Guide 87 sparing options 24 understanding disk states 22 document conventions 9 prerequisite knowledge 9 E errors physical disks cannot initialize a disk 72 dedicated hot spare has failed or is in error 72 Failed status is displayed 72 the wrong disk was removed 72 event notifications setting 64 Event View section Array Status window 49 expand arrays future 21 disk capacity online OCE 21 future arrays 21 F flexibility and expansion 25 follow arrays using rcadm 84 formatting arrays with Windows Disk Management 54 G global spares adding 61 62 63 removing 61 62 63 global sparing 24 H Help and About windows 46 hot spares cannot create 70 initialize disks 50 BIOS Configuration Utility 28 INT13 disabled warning message 68 L legacy disks 52 usage 52 logs viewing 63 monitor arrays using rcadm 84 N new arrays create using rceadm 82 new disks 52 O OCE Online Capacity Expansion 21 operating systems supported by AMD RAID 13 Options menu changing a password 46 options sparing 24 ORLM Online RAID Level Migration 21 P partitioning arrays with Windows Disk Management 54 passwords changing a password from the Options menu 46 changing settings 63 protection using RAI
105. to a smaller sized array The transformed array must be the same size as or larger than the original array Array size limits The array size of the transformed array is limited to 2 199 TB on some versions of the Windows and Linux operating systems Refer to the operating system documentation for details on maximum array sizes Disk failure during a If a disk fails while the Transform task is in progress no data is lost as long as the Transform source and destination RAID levels are redundant If a spare has been assigned to the destination array a fail over task starts as soon as the Transform completes if the spare is available after the Transform Multiple arrays If there are multiple arrays it might not be possible to transform some of the arrays to a larger size If in the future an array needs to be expanded in size it is best to configure the available space as a single array Task control commands When using task control commands a Transform task can only be paused or resumed but not removed To end a Transform task pause and delete it EYNOTE Ifa task is paused and then deleted the array is deleted Deleting a task is the same as deleting an array Data loss occurs when a task is deleted Please ensure that data is backed up prior to deleting a task involving a Transform or a Restore System reboot during a__ If the system reboots during a Transform the Transform continues where it left off
106. tting up 64 rescan all channels 32 disks 51 for changes in state 23 restore rebuild task restoring rebuilding a Critical array 56 S spares dedicated adding 61 dedicated removing 61 global adding 61 62 63 global removing 61 62 63 sparing dedicated 24 global 24 spinup count changing 33 staggered spinup count changing 33 swap arrays BIOS Configuration Utility 30 system requirements for RAIDXpert2 13 system startup problems 67 T tasks canceling 59 interrupting 59 priority level changing 59 Troubleshooting a dedicated hot spare has failed 72 a disk has failed 72 BIOS Configuration Utility does not display 67 cannot create a global hot spare 70 cannot create an array 69 cannot initialize a disk 72 recreating a deleted array 72 system does not boot 67 system startup problems 67 the wrong disk was removed 72 warning messages POST screen 68 U user manual who should use it 13 V view help from the readm Command Line 82 virtual disks errors 69 troubleshooting 69 volumes larger than 2 TB with Windows Server 2003 71 WwW warning messages POST screen 68 BIOS Not Installed User Disabled INT13 BIOS Load 68 Found arrays that are Critical 68 Found arrays that are Critical and Offline 68 Found arrays that are Offline 68 RAIDXpert2 User Guide 89 90
107. ures which until recently have been platform specific BIOS Mode Di eG oy Power on the system In the BIOS setup set or configure the SATA Mode to RAID In the BIOS setup set or configure the Boot mode to Legacy Make sure that the AMD RAID bootable array is included in the system s boot priority list At the system s Power On Self Test POST screen press Ctrl R to access the AMD RAID Array Configuration Utility aka Option ROM or O ROM Scroll to Controller Options Make sure that INT13 Boot Support is ON for AMD RAID If more than one array exists at the AMD RAID Array Configuration Utility make sure that the desired bootable array is the first array listed in the Arrays list Use the Swap Two Arrays task to place the bootable array first UEFI Mode 36 OE Ne ms Power on the system In the BIOS setup set or configure the SATA Mode to RAID In the BIOS setup set or configure the UEFI Boot to Enable In the BIOS setup set or configure the SATA supporting as to UEFI Mode At the system s Power On Self Test POST screen press F7 F12 ESC or similar to access the UEFI Configuration Utility aka UEFI Boot Manager Boot to the EFI Internal shell Enter sx where x is the number of the UEFI Flash Drive Use rcadm to create the desired Boot Virtual Disk Software Installation Installing AMD RAID drivers Follow the procedures below for your Microsoft Windows or Linux installation Installing AM
108. w contain lists of commands The commands allow the system user to initiate or modify array and disk related tasks Not all commands are available for an array or for the system Availability depends on e The tasks that can be performed with the system s license level e The RAID level of an array For example a Consistency Check can be performed only on arrays at a redundant RAID level e The remaining capacity of the disk drives For example if a system has three disk drives and large arrays have used all of the capacity on two of the disks only non redundant Volume arrays can be created on the remaining disk Certain commands are not available with a non redundant array Table 19 provides page numbers for each command RAIDXpert2 User Guide 49 Table 19 Commands at the Array and Disk menus Array Commands See detailed Disk Commands See detailed information information on this page on this page Create page 52 Rescan page 50 Transform page 54 Initialize page 50 Check Consistency Spare Identify Background Array Scan Properties Modify Cache Settings Mirror Task Name Hide Prepare to Remove Remove Spares Copy Unlink Delete Secure Erase Working with Disks Initialize Disks 50 When a disk is initialized RAIDXpert2 configuration information metadata is written to the disks If a disk is new and has not been used before or if it is a legacy disk
109. wT RAIDXpert2 RAIDXpert User Guide P N 83 00006608 1 2 04 Revision A March 2013 Copyright Protected Material 2012 2013 All rights reserved All other trademarks and registered trademarks are proprietary to their respective owners The material in this document is for information only and is subject to change without notice While reasonable efforts have been made in the preparation of this document to assure its accuracy changes in the product design can be made without reservation and without notification to its users Ca Adobe PostScript Contents Preface9 Intended audience 9 Prerequisites 9 Document conventions and symbols 9 Customer Support 9 1 Safety Precautions11 General 11 Safety Definitions 11 Caution Messages 11 Caution Messages about Disks 11 Caution Messages about Arrays 12 2 Getting Started13 RAIDXpert2 Technology 13 Who Should Use This Manual 13 System Requirements for Using RAIDXpert2 13 Supported Controllers 13 Supported Operating Systems 13 Features of RAIDXpert2 14 RAIDXpert2 Feature Set 16 3 Arrays Disks and RAID Levels19 Understanding Arrays 19 RAID Levels 19 Array States 20 Creating Arrays Future Expansion 21 Expanding Disk Capacity Online Using OCE supported by RAIDXpert2 Plus 21 Migrating RAID Levels Online Using ORLM supported by RAIDXpert2 Plus 21 Array Tasks Starting and Stopping Tasks 22 Understanding Disks 22 Disks States 22 Rescanning Disks for Changes in State
110. wants data redundancy for the user data and creates a RAIDS set using part of the disks data At the same time the administrator wants performance for the swap spaces and creates a RAIDO array using the rest of the disks capacities space This feature is useful in collecting unused capacity from disks with different capacities g This feature increases data integrity for redundant array types by logging areas of an array that have been written to In the event of a system crash the logged area s consistency is checked and or corrected Without this feature data corruption might occur h Arrays can be instantly created and used by skipping the background consistency check For certain types of redundant arrays this is a viable option and has no data integrity drawbacks A consistency check can always be done at a later time If an initialization is skipped when using RAIDS the array is not redundant until a consistency check is performed i Disks can be added to the system and to an array while the system is operating 18 Getting Started 3 Arrays Disks and RAID Levels Understanding Arrays Arrays are several disks that are grouped together to improve either the performance or reliability of a storage system Because some RAID levels enhance performance while others improve reliability it is important to consider the user s needs when planning an array configuration f NOTE Itis highly recommended that this user manual
111. window a Select I accept the terms of the License Agreement b Click Next What would you like to install window Click Next Choose Install Folder window Choose Shortcuts window a Accept the default settings b Click Next Click Next Pre Installation Summary window a Review the selections b If they are okay click Install NOTE The Installing the AMD RAIDXpert2 Management Suite window appears showing the progress of the installation Install Complete window Software Installation Click Done Installing the AMD RAIDXpert2 Graphical User Interface GUI This section provides instructions for installing the AMD RAIDXpert2 GUI for Linux For information on using the GUI see AMD RAIDXpert2 Graphical User Interface GUI on page 45 SLED Linux 1 Copy xampp linux 1 8 1 tar gz to the desktop 2 Open a console window 3 Navigate to root Desktop 4 Start Super User su mode and enter tar xvfz xampp linux 1 8 1 tar gz C opt cd opt raidxpert2 htdocs cp rv raidxpert2 opt lampp htdocs 5 To start lamp enter opt lampp lampp start 6 Restart Apache Enter usr lampp lampp startapache NOTE This must be done after each system reboot A RAIDXpert2 icon appears on the desktop Ubuntu Linux 1 Open a console window Copy xampp linux 1 8 1 tar gz to the desktop Navigate to root Desktop and enter sudo tar xvfz xampp linux 1 8 1 tar
112. ws a RAIDABLE disk to be See RAIDO striping on page 19 or transformed later to RAIDO or RAID1 RAID1 mirroring on page 19 for Supports 1 disk post transformation usefulness Array States Within the management applications an array is a logical device that can exist in one of three states Normal Critical or Offline e In RAIDXpert2 these states display in the Array List section in a column named State e Within the rcadm Command Line tool these states also display in a column named State The array states are defined in Table 6 Table 6 Array states State Description The Normal state is displayed when everything is functioning correctly The Ready state is displayed while an array is being created The Critical state is displayed when the array is no longer redundant fault tolerant because of one or more disk failures Arrays can still be read and written to but the data is no longer protected should another disk fail The Offline state is displayed when arrays cannot be read or written to because of one or more disk failures Whether an array is marked as Critical or Offline depends upon what RAID level it is and how many disks within the array have failed Note the changes in state in Table 7 Table 7 Failure states by RAID level RAID Level This Failure State Is Displayed Whenever RAID1 RAIDS Critical A single disk fails redundant arrays Offline Two or more disks fail
113. y RAIDXpert2 Plus Online RAID Level Migration ORLM allows an array to move from one RAID level to almost any other RAID level This task includes migrating the array from a non redundant RAID level to a redundant RAID level Prior to starting a RAID level migration transformation make sure that the disks selected for the destination array have sufficient capacity RAID level migration transformation can occur only when the destination array has the same or larger capacity as the source array While the migration transformation is taking place data is accessible and protected to the lowest protection of either the source RAID level or the destination RAID level The Transform task can also be used to expand the capacity of an array by using OCE It can also be used as part of the system backup and recovery strategy through the use of the RAID1 and RAID10 RAID levels To perform this process see Transform Arrays supported by RAIDXpert2 Plus on page 54 RAIDXpert2 User Guide 21 Array Tasks Starting and Stopping Tasks Tasks are started when one of the following actions are performed e Create a redundant array e Transform an array e Restore an array e Securely erase an array e Check for consistency on redundant arrays e Verify that data was not corrupted after a system crash Check_Bitmap performed automatically Full task control can be used on Create Consistency Check and Bitmap Check tasks On a Transform or Restore
114. ys RAIDABLE arrays are a special type of JBOD that allow the user to add more storage space or create a redundant array after a system is installed RAIDABLE arrays are created using OpROM UEFI or rcadm NOTE The ability to create RAIDABLE arrays may not be available on your system 26 Arrays Disks and RAID Levels 4 BIOS Configuration Utility When to Use the AMD RAID Controller BIOS Configuration Utility The AMD RAID Controller BIOS Configuration Utility is also known as the Option ROM O ROM Use the utility to accomplish the procedures indicated in Table 12 Table 12 When to use the AMD RAID Controller BIOS Configuration Utility Option ROM Procedure Initialize a new disk Description To initialize a new disk drive for data storage Find Information At Initialize Disks on page 28 Create or delete arrays Create arrays at different RAID levels depending on the license level for the system or delete an array Create Arrays on page 28 Delete Arrays on page 30 Swap arrays Change the array order especially for the AMD RAID bootable array Swap Arrays on page 30 Manage hot spares Allows selection of global and dedicated hot spares Manage Spares on page 31 View disk and array details View information about each disk or array View Disk Details on page 32 View Array Details on page 32 Rescan all channels Rescan all channels to detect new or removed
115. ys and place the RAIDXpert2 bootable array in the first position Create An Array NOTE The ability to create RAID10 arrays may not be available on your system 1 At the Main Menu use the arrow keys to highlight Create Array 2 Press Enter 3 Select the disks with which to create the array e To select all disks press the A key e To select individual disks highlight a disk with the arrow keys and press Insert Any number of disks may be selected using this method 4 Press Enter to include the selected disks in the array 5 In the User Input section use the arrow keys to select an array type Only array types that can be created with the selected disks are available 6 Press Enter 7 Select an array size To create an array whose size is less than or equal to 2 199 TB a Press the Page Up or the up arrow key to increase the array size and the Page Down or down arrow key to decrease the size b Press Enter when the desired size is reached To create an array whose size is greater than 2 199 TB a Press the Page Up or the up arrow key to increase the array size and the Page Down or down arrow key to decrease the size b When an array size of 2 199 TB is reached a message states that a size greater than the maximum is being attempted and whether the size of the array should be limited c Press Esc to create an array larger than 2 199 TB d Press the Page Up Page Down or the up down arrow keys to continue modify
Download Pdf Manuals
Related Search
Related Contents
MAQUINA TAPACOSTURA Lucent Technologies Answering Machine 107970212 User's Manual Welcome to use HP Compaq 6730s CAUTION ATTENTION PRECAUCIÓN CUIDADO User manual visCrypt CareLink Mobile Nurse Station and Telepresence Carts User Manual ガイアノーツカタログ Instrucciones de servicio Copyright © All rights reserved.