1. rOSSLN w SECURITY PRODUCTS Installation Instructions PYR 2011A Advanced Wireless PIR 1 Introduction The PYR 2011A Digital Wireless Passive Infrared PIR motion detectorisa high performance ultra low power intrusion sensor with advanced desgn ideal for resdential and commercial applications The PYR 2011A s SSFL tec hnology look down allows detection at proximity of 50 cm from its mounting location This unit works with Rosslare s control panels such as HomeLogixX which is wireless and Aura Sys which is wired For the PYR 2011A to work with Aura Sys the Aura Sys panel mus have the XR 16 wireless expansion The PIR senses sight motion within a coverage area by detecting infrared energy with a Pyroelectric sensor Serving asan anti intrusion sensor the PIR can monitor open space within the line of sight The Walk amp Radio test is imple and user friendly and is easy to place and set The PYR 2011A uses fuzzy logic to improve detectionsand reduce false alams It also provides digital temperature compensation and self test capability The PYR 2011A is supplied with front and back tampers for high sec unity Asa wireless device itincludesa supervised mechanism aswellas a battery checkerand tamper announcement CAUTION Changesor modifications to this equipment not expressly approved by the party responsble forcompliance Rosslare Ltd could void the user s authonity to operate the equipmen
2. Global Technical Support amp Training Center HaMelecha 22 Rosh HaAyin Israel 48091 Tel 972 3 938 6838 Fax 972 3 938 6830 Email sup port eu rossla resec urity com South America Presbitero Actis 555 Oficina 31 San Isidro Buenos Aires Argentina Tel 5411 5273 6383 Tel 305 921 9919 E mail support la rosslaresecurity com Website www rosdiaresecunty com 0706 09601 10 03
3. careful not to touch the pyroelectric unit on the board Touching the unit will gravely affect the unit s ability to work propery i f j r Ca i f 4 5 Closing the Detector After mounting the detector insert a battery refer to Section 6 Place the PCB backin place and close the detectorin reverse order Wait forthe detector to finish its self test referto the Signaling Table in Section 9 NOTE When using the swivel mount referto the BR 11 installation manual 5 Adding the Curtain Adapter Use the curtain adapter for detecting movement in nanow places comdors or across surfaces window You will need to remove the lens only to add or remove the curtain adapter To add the curtain adapter 1 Tum the top part of the PYR 2011A overand locate the lens holder pin A 2 Remove the pin by positioning a screwdriver under the holder pin and gently lifting the pin up out of its place b 3 Gently push the two latches on the side of the lens inwards tum the housing over and pop off the lens Place the curtain adapteronto the lensarea on the front of the housing Be sure to place the guide pins into the two holesat the lower part of the lensarea Replace the lens Tum the whole assembly overand replace the holding pin that holdsthe sohenical lensin place Be sure to place the holding pin between the lenstab and the housing with the flat side toward the lens
4. ction gt 20 V m up to 1000 MHz 2 5 Physical Characteristics Dimensions 127 x 80 x 63 mm 5 x 3 15 x 2 48 inch fits US Gang Box Weight 0 27 Ibs 123 g without battery Compliance with standard CE EN 50131 2 2 Grade 2 Classi TOP VIEW 3 PYR 2011A Features e Advanced micro contoller electronics 10 bit A to D and advanced algonthms for supenor movement speed spectrum analysis Shielded dual element Pyro Inside a dust proof chamber designed to reduce thermal changes and insect protection e Three levels of sensitivity High medium low by jumper selection Power saving Two transmission modes by jumper Back and front cover tamper switches Protection against cover or wall removal for increased secunty e Easy amp comfortable installation Ea sy installation without PCB adjustment e Easy Walk amp Radio test By single contactless switch e Energy detection system By using fuzzy logic algorithms detection is improved and false alarmsare reduced e Environment temperature compensation Maintains constant detection capability Adaptive filter Compensates forchangesin a detected object s speed e Continuous monitoring Sends visual alerts in case of malfunction digital and analog and temperature out of range 0706 09601 10 03 4 Installation 4 1 General The PYR 2011A is designed for easy installation Only a few steps are needed to install the PIR device To enable the Curtain Adapter for PIR detec
5. e center Exclusions and Limitations ROSSLARE shall not be responsible or liable for any damage or loss resulting from the operation or performance of any Product or any systems in which a Product is incorporated This warranty shall not extend to any ancillary equipment not furnished by ROSSLARE which is attached to or used in conjunction with a Product nor to any Product that is used with any ancillary equipment which is not furnished by ROSSLARE This warranty does not cover expenses incurred in the transportation freight cost to the repair center removal or reinstallation of the product whether or not proven defective Specifically excluded from this warranty are any failures resulting from Customer s improper testing operation installation or damage resulting from use of the Product in other than its normal and customary manner or any maintenance modification alteration or adjustment or any type of abuse neglect accident misuse improper operation normal wear defects or damage due to lightning or other electrical discharge This warranty does not cover repair or replacement where normal use has exhausted the life of a part or instrument or any modification or abuse of or tampering with the Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim ROSSLARE does not warrant the installation maintenance or service of
6. indicator illuminates 2 Tenalarm eventsare transmitted every 4seconds 0706 09601 10 03 9 Signaling Table The LED on the front of the PYR 2011A is used to send several Signals to the user The following table describesthe signals for different activities The LED flashes on for2 secondsand off for 2 seconds fora penod of 1 minute If the warmup is successful the LED stops flashing and the system is ready for detection Detect Condition The LED flashes on for 2 secondsand then tums off PIR Problem The LED flasheson for 1 second and then off for1 second A PIRcheckisconducted every 3 hours Temperature The LED flashes on in short bursts Problem Weak Battery LED OFF and ON altemately during Alam Tamper event 10 Limited Warranty ROSSLARE ENTERPRISES LIMITED ROSSLARE ONE YEAR LIMITED WARRANTY is applicable worldwide This warranty supersedes any other warranty ROSSLARE S ONE YEAR LIMITED WARRANTY is subject to the following conditions Warranty Warranty of ROSSLARE S products extends to the original purchaser Customer of the ROSSLARE product and is not transferable Products Covered By This Warranty and Duration ROSSLARE ENTERPRISES LTD AND ORSUBSIDIARIES ROSSLARE warrants the PYR 2011A Advanced wireless PIR to be free from defects in materials and assembly in the course of normal use and service The warranty period commences with the date of shipment to the original purchaser and extends for a period
7. of 1 year 12 months Warranty Remedy Coverage In the event of a breach of warranty ROSSLARE will credit Customer with the price of the Product paid by Customer provided that the warranty claim is delivered to ROSSLARE by the Customer during the warranty period in accordance with the terms of this warranty Unless otherwise requested by ROSSLARE representative return of the failed product s is not immediately required If ROSSLARE has not contacted the Customer within a sixty 60 day holding period following the delivery of the warranty claim Customer will not be required to return the failed product s All returned Product s as may be requested at ROSSLARE sole discretion shall become the property of ROSSLARE To exercise the warranty the user must contact ROSSLARE to obtain an RMA number after which the product must be returned to the Manufacturer freight prepaid and insured In the event ROSSLARE chooses to perform a product evaluation within the sixty 60 day holding period and no defect is found a minimum US 50 00 or equivalent charge will be applied to each Product for labor required in the evaluation ROSSLARE will repair or replace at its discretion any product that under normal conditions of use and service proves to be defective in material or workmanship No charge will be applied for labor or parts with respect to defects covered by this warranty provided that the work is done by ROSSLARE or a ROSSLARE authorized servic
8. sensitivity modes were desgnated e Low for harsh environments jumperon pins2 and 3 e Medium for nomal usage jumper off e High for high sensitivity when there is little chance of false alams jumperon pinsland 2 7 2 APS Auto Power Save Mode JP1 To save power the PYR 2011A goesinto Seep mode after sending analam The time the device islatent isset by the radio mode jumper J P1 e Normal always 2 minutes between ala ms no jumper e Dynamic 2 minutes retriggered between alams jumperon When the dynamic mode isset an alam event is sent only if there were 2 minutes of silence prorto the current alam This setting is useful for places with a high level of traffic such asfactonesand shops 7 3 Back Tamper R11 NOTE When using the comer mount or bracket the back tamper is notapplicable The PYR 2011A has both front and back tamper detection The back tamperand front coverare setina res One tampercan be stimulated only when the other is closed Front tamper detection ison by default and itisactivated when the coverisopened The back tamper detection is activated when the detectoris pulled off the wall and isdisabled by default To enable the back tamper detection cut the back tamper wire R11 which ismarked on the PCBasSa scissor print 7 4 Test Mode Switch S3 The detector utilizesa contactless switch which enables easy testing without opening the case Walk test Place a magnet overthe right
9. side of the lensfor1 second only PIR functionality isevaluated fora 1 minute penod refer to Section 8 Radio test Place a magnet over the right sde of the lens for more than 3 seconds the red indicator illuminates refer to Section 8 In all modes the LED remains active at all trouble announcements Refer also to the panel manual for RF testing details 8 Testing the Detector The PYR 2011A PIR has built in walk test and radio test functions where the LED of the PIR is enabled The walk test is used to check the detection of the PIR and the coverage pattem Aftera self check at powerup the walk test is automatically enabled for 2 minutes To perfom a walk test 1 Ensure all of the settingsin the PIR are adjusted as necessary forthe location according to the installation instructions above 2 Place a magnet overthe right side of the lensfor1 second only 3 With the LED enabled the LED fla shes every time the detector detects motion There isa 2 second wait penod before the next detection 4 Itisrecommended that the Installer test the detection by going overthe protected area and seeing that the detection pattem isgood 5 After 1 minute the LED goes off If a new walk test is needed repeat Steps 3 to 5 The radio test is used to ensure a clear RF Sgnal passes between the detector and the control panel To perfom a radio test 1 Place a magnet overthe right side of the lens formore than 3 seconds the red
10. t 2 Technical Specifications 2 1 Optical Characteristics Lens Type Spherical Field of view 90 Max Coverage 12 x 12 m 39 5 x 39 5 ft No vertical adjustment 2 2 Electrical Characteristics Battery type C R123 3 V 1300 mhA Current Consumptions Standby 15 ua 10 ma transmission Battery Life nominal 3 years 150 tr day Detector Type Dual PYRO IR element IR filter 5 um 14 um Alam Signaling Red LED 2 seconds on push button setting Events Transmission Alarm Tamper Low battery Sensitivity 3 levels fuzzy logic jumper setting Speed Detect 0 2 m s 3 m s At 1 1 C 0 66 ft s 9 84 ft s At 34 F Temperature Compensation Digital dual slope 1 C Tamper Switches Back and front cover tampers Supervisory Signals Electronic malfunction temperature out of range by flashing LED Aming types Nomal 2 minutes sleep followed by last alarm Dynamic 2 minutes sleep followed by last movement retrigger Test modes walk test no sleep 1 min Radio test 10 transmissions 2 3 RF Transmission Characteristics Frequency model H 868 35 MHz model G 433 92 MHz Range 200 meters 590 55 ft open field conditions Supervision transmission auto matic at 20 minute intervals Self check 3 hours from last alam retriggered 2 4 Environmental Characteristics Operating Environment Indoor use Operating Temperature 10 C to 60 C 14 F to 140 F Operating Humidity 0 to 95 non condensing RA Prote
11. tab Lens Curtain Adaptor 10110 03 6 Changing the Battery When the battery is weak the PYR 2011A sendsa signal to the panel including LED signals referto the Signaling Table in Section 9 indicating a weak battery Although the detectorcan continue working foran additional amount of time it is prudent to replace the battery assoon aspossible To change the intemal battery 1 Follow the directions in the Section 4 2 Opening the PYR 2011A 2 Remove the PCB unit from the housing by pressing down on the retaining latchesand tilting the PCB out from the bottom 3 Remove the battery and replace with a 3 VDC 1300 mAh model CR123A only Pay attention to the polarity of the battery when inserting into the holder CAUTION There isa danger of exploson if the battery is replaced incorectly Replace only with a 3V Lithium GPCR123A or equivalent Dispose of used battenes according to the manufacturer s instructions 4 Replace the PCBcoverof the PYR 2011A and the locking screw Battery Place rT PYR 2011 PCB Back View 7 Jumper and Tamper Setting The PYR 2011A hastwo jumpers J Pl and J P2 and reed switch S3 test mode which isoperated by placing a magnet overit EnA Fap ea J a TONS IE oye LY JE O Z Alea PYR2011H G V6 pa 101 0201246 06 FA 7 1 Sensitive Level Jumper JP2 To prevent false alarmsin harsh environments three
12. tection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television 12 Contact information Asia Pacific Middle East Africa Headquarters 905 912 Wing Fat Industrial Bldg 12 Wang Tai Road Kowloon Bay Hong Kong Tel 852 2795 5630 Fax 852 2795 1508 Email support apac rosslaresecunty com United States and Canada 1600 Hart Court Suite 103 Southlake TX USA 76092 Toll Free 1 866 632 1101 Local 1 817 305 0006 Fax 1 817 305 0069 Email sup port na rosslaresec unty com lt ROHS TUV Rheinland Sannin COMPLIANT ISO 9001 2008 Cert Me 01 100 6925 50 14001 20 Cear No 01 104 6925 4 reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Europe
13. the Product Service life of the product is dependent upon the care it receives and the conditions under which it has to operate In no event shall ROSSLARE be liable for incidental or consequential damages Limited Warranty Terms THIS WARRANTY SETS FORTH THE FULL EXTENT OF ROSSLARE ENTERPRISES LTD AND IT S SUBSIDIARY S WARRANTY THE TERMS OF THIS WARRANTY MAY NOT BE VARIED BY ANY PERSON WHETHER OR NOT PURPORTING TO REPRESENT OR ACT ON BEHALF OF ROSSLARE THIS LIMITED WARRANTY IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE SPECIFICALLY EXCLUDED INNO EVENT SHALL ROSSLARE BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT OR FOR ANY OTHER INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF USE LOSS OF TIME COMMERCIAL LOSS INCONVENIENCE AND LOSS OF PROFITS ARISING OUT OF THE INSTALLATION USE OR INABILITY TO USE SUCH PRODUCT TO THE FULLEST EXTENT THAT ANY SUCH LOSS OR DAMAGE MAY BE DISCLAIMED BY LAW THIS WARRANTY SHALL BECOME NULL AND VOID IN THE EVENT OF A VIOLATION OF THE PROVISIONS OF THIS LIMITED WARRANTY 11 Declaration of Conformity This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable pro
14. tion on a focused area such asa comdororacrossa window oropening follow the instruction outlined in Section 5 When you are sure of the mounting location follow the steps for mounting the PIR on a flat surface orina comer asdescnbed below 4 2 Opening the PYR 2011A The PYR 2011A housing can be opened by unscrewing it with a Philipshead screwdriver 1 and pushing the safety latch 2 to unlock 4 3 Mounting the PYR 2011A PIR Selectan area formounting the PYR 2011A and ensure the location is flat eithera wall ora 90 degree comer for perfect mounting of the unit Ensure the PIR hasa view of the area under surveillance and isfree from obstructions The PYR 2011A hasa detection range of 14 7 m 48 ft when placed ata height of between 1 8m and 2 3 m To mount the PYR 2011A PIR 1 When usng the comer mount you must first place the plastic bracket in the comerat the exact chosen location Pay attention that the namow edge faces downwards the bracket hasa direction 2 Attach the bracket firmly to the wall all 4 screws must be inserted 3 Insert the body of the PYR into place over the plastic bracket using the comer mounting holes The plastic pipe pole should pressthe back tamper corectly 4 4 Wall Mounting The PIR housing has dimple points for insertion of screws for either wall mounting orcomermounting refer to detailed pictures below Remove the PC board pnorto mounting CAUTION Be
Download Pdf Manuals
Related Search
Related Contents
Fujitsu fi-4750C User's Manual Delta Electronics H48SL User's Manual Hunter manual Simplified guided surgery user`s guide EN60950-1 - Summit Data Communications Bedienungs-und Wartungsanleitung WAREMA Raffstore mit Winegard MA1055G User's Manual AM User manual Arquivo 1 Copyright © All rights reserved.