1. Soni AR 2 eee a Digicode avec lectronique int gr e Self contained Keypad braille keys Range Locking Devices Gamme Verrouillage INSTALLATION MANUAL MANUEL D INSTALLATION CDVI Group Products avec lectronique int gr e Touches braille Merci pour l achat de ce produit et pour la confiance que vous accordez notre entreprise 1 PRESENTATION PRODUIT m Inox m Touche en braille Etanch it IP54 3 relais 2 leds m Pose en applique Montage avec vis Diax Protection de la carte lectronique par tropicalisation m 100 codes utilisateurs EJ JE M PS ud 189 8 a Signalisation sonore a Circuit lectronique vernis tropicalis S lgicoda protection contre un fort taux d humidit Bouton d ouverture de porte par la touche 0 a Dimensions L x I x P 125 x 100 x 65 mm Alimentation 12 V 24 V AC 12 V 48 V DC Consommation 140 mA HAUTE R SISTANCE AU VANDALISME 1 54 x C Es ING Ze Alimentations Certification CE pr conis es 20 50 7 FE Certification FCC CFR 47 _ part 15 compliance ARD12 BS60 e RoHS 2 RAPPELS ET RECOMMANDATIONS Alimentations pr conis es Composition des codes Il existe deux alimentations adapt es Par souci de s curit veillez modifier le code pour le clavier cod ARD12 et BS60 ma
2. 1 x bip OK led verte allum e led verte allum e led verte allum e led verte allum e led verte allum e 4 x bip erreur Tapez pour sortir de la programmation led rouge teinte cdvi com 10 cdvigroup com MANUEL D INSTALLATION CBB Digicode avec lectronique int gr e Touches braille led verte allum e 1s 1 x bip Tapez ensuite led verte allum e Termes de modification relais 1 led verte allum e 1s 1 x bip 2 chiffres led verte allum e Termes de modification relais 2 led verte allum e 15 1 x bip led verte allum e Termes de modification relais 3 led verte allum e is 1 x bip led verte allum e Signal sonore led verte allum e 1s 1 x bip 0 supprimer les bips 1 autoriser les bips 1 x bip OK 4 x bip erreur Programmation des codes 4 50u6 chiffres rouge rang occup led verte rang libre cdvi com cdvigroup com ined Keypad braille keys Thank you for buying our products and for the confidence you placed in our company 1 PRODUCT PRESENTATION m Stainless steel m Braille keys Weatherproof IP54 m 3 relays 2 leds Surface mount m Installation with Diax screw Varnish coated PCB 100 user codes a Audible and visual feedback PCB protected against humidity by varnish coating a Request to enter Trade can b
3. The keypad is no longer in the programming mode and the default values have been restored Remove the jumper at P2 3 The master code is 1 2 3 4 5 again and all the codes have been erased The default values have been restored cdvi com cdvigroup com 15 B Setting code length 1 Enter the master code twice For the first use the factory master code is 1 2 3 4 5 2 Press 4 to input the number of digits in the codes Green LED lights on for 1 second Enter 4 5 or 6 for number of digits Press k and to confirm The green LED lights on for 1 second to confirm the new code length 3 Press 5 to change the master code Green LED lights on for 1 second Enter the 4 5 or 6 digits of the new master code The green LED lights on during 1 second to confirm the new master code You MUST change the master code before you exit from programming if you have changed the digit length 4 Press to exit from the programming mode The red LED lights off to confirm that the keypad is in stand by operating mode Red LED flashing 4 times indicates a data computing error C Programming a New Master Code 1 Enter the master code twice For the first use the factory master code is 1 2 3 4 5 Red LED lights on to confirm entry in programming mode 2 Press 5 to program the master code Green LED lights on for 1 second Enter 4 5 or 6 for number of digits Press and to confir Th
4. 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code maitre usine est 12345 La led rouge s allume pour confirmer l entr e en programmation 2 Tapez 5 La led verte s allume 1s cdvi com 6 cdvigroup com ctronique int gr e Touches braille Tapez les 4 5 ou 6 termes du nouveau code maitre La led verte s allume 1s pour confirmer la programmation 3 Tapez pour sortir de la programmation La led rouge s teint pour confirmer le retour au mode normal de fonctionnement Programmation des codes Relais 1 Groupe 1 Du rang 00 au rang 59 Relais 2 Groupe 2 Du rang 60 au rang 79 Relais 3 Groupe 3 Du rang 80 au rang 99 Code Ma tre Code Maitre Led rouge allum e Pour programmer des codes 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code maitre usine est 12345 La led rouge s allume pour confirmer l entr e en programmation 2 Tapez le n du rang programmer de 00 99 Si le rang est libre la led verte s allume 1s tapez les 4 5 ou 6 termes du code Si le rang est occup la led rouge clignote 4 fois Tapez les 4 5 ou 6 termes du code ou tapez0000000u00000 ou pour annuler le code existant La led verte s allume 1s pour confirmer la programmation Si le code entr correspond un code existant ou s il est identique au code ma tre la led rouge clignote 4 fois pour indiquer une
5. 12 3 4 5 Red LED lights on to confirm entry in programming mode INSTALLATION MANUAL CBB Self contained Keypad braille keys 2 Enter 0 for the key in keypad time Green LED lights on for 1 second Enter the duration time in second E g From 10 for 10 seconds to 99 for 99 seconds The green led lights on to confirm the programming 3 Press 1 for output time of relay 1 Green LED lights on for 1 second Enter the duration in seconds E g From 01 for 1 second to 99 for 99 seconds or enter 00 for a permanent illumination The green led lights on to confirm the programming 4 Press 2 for output time of relay 2 Green LED lights on for 1 second Enter the duration in seconds E g From 01 for 1 second to 99 for 99 seconds or enter 00 for a permanent illumination The green led lights on to confirm the programming 5 Press 3 for output time of relay 3 Green LED lights on for 1 second Enter the duration in seconds 6 Press to exit from the programming mode The red LED lights off to confirm that the keypad is in stand by operating mode Red LED flashing 4 times indicates a data computing error F Resetting the master code In normal operation place a jumper at P2 Green LED lights on to confirm entry in programming mode 2 Enter 0 for the key in keypad time Green LED lights on for 1 second A beep is emitted Wait for the green LED to light off R
6. 99 sec 4 5 or 6 4 5 or 6 00 toggle 00 toggle 00 toggle digits digits Green LED lights on Green LED lights on Green LED lights on Green LED lights on Green LED lights on Press to exit from programmation Red LED lights off cdvi com 20 cdvigroup com INSTALLATION MANUAL EN CBB Self contained Keypad braille keys green LED on for 1 sec 1 x beep Press then Green LED lights on Sub master code 1 green LED on for 1 sec 1 x beep 2 digits Green LED lights on Sub master code 2 green LED on for 1 sec 1 x beep Green LED lights on Sub master code 3 green LED on for 1 sec 1 x beep Green LED lights on Buzzer audible feedback green LED on for 1 sec 1 x beep 0 Buzzer disabled 1 Buzzer enabled User codes 4 5 or 6 digit 4 x red LED User location Used Green LED User location Free cdvi com cdvigroup com 21 Keypad braille keys cdvi com 22 cdvigroup com INSTALLATION MANUAL t CBB Self contained Keypad braille keys cdvi com cdvigroup com 23 Reference GO30i1FRO106V02 Extranet EXE CDVI_IM CBB CMYK A5 EN FR 01 Manufacturing Access Control since 1985 hout prior notice N Uu Uu e 5 TD o Uu iS 9 4 o o o Uu ui 3 4 o uy ce ie a f sur le pr sen
7. Alimentation 12V 24V AC ou 12V 48V DC Clavier 12 touches braille Led rouge et verte pour la visualisation Sauvegarde m moire permanente E2PROM 100 codes programmables en 4 5 ou 6 termes 1 relais d ouverture 1 contact RT 8A 250V 2 relais d ouverture 1 contact 6A 250V Code maitre programmable en 4 5 ou 6 termes Buzzer de signalisation 1 bouton poussoir de sortie commandant l ouverture Cavalier P2 code ma tre usine 12345etraz des codes Cavalier P3 modification des codes par l utilisateur Valeurs par d faut Aucun code Tempo clavier 10 s Tempo d ouverture pour tous les relais 1 s Nombre de termes 5 Code maitre usine 1 2 3 4 5 Tempo s curit programmation 120s Codes de modification par utilisateur pour le 1 groupe A et B Codes de modification par utilisateur pour le 2 groupe 1 et 3 Codes de modification par utilisateur pour le 3 groupe 4 et 6 La led rouge s allume la mise sous tension Correspondance des signaux sonores 1 bip court Mise sous tension 1 bip long Validation d une saisie en programmation et ouverture 2 bips courts Entr e ou sortie de programmation 4 bips courts Erreur de saisie Termes utilis s et codes d ouverture Toutes les touches du clavier sont autoris es pour composer les codes Le code maitre et les codes d ouverture de porte doivent
8. erreur Les codesO000000u00000 ou servent annuler un code existant et ne peuvent donc pas servir comme code d ouverture de porte 3 Tapez pour sortir de la programmation la led rouge s teint pour confirmer le retour au mode normal de fonctionnement MANUEL D INSTALLATION CBB Digicode avec lectronique int gr e Touches braille E Programmation des temporisations 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code maitre usine est 123 4 5 La led rouge s allume pour confirmer l entr e en programmation 2 Tapez 0 pour la temporisation du clavier La led verte s allume 1s Tapez la dur e de commande en secondes La led verte s allume 1s pour confirmer la programmation 3 Tapez 1 pour la temporisation du relais 1 La led verte s allume 1s Tapez la dur e de commande en secondes 01 pour 1 seconde jusqu 99 pour 99 secondes La dur e 00 correspond au fonctionnement bistable du relais 1 La led verte s allume 1s pour confirmer la programmation 4 Tapez 2 pour la temporisation du relais 2 La led verte s allume 1s Tapez la dur e de commande en secondes 01 pour 1 seconde jusqu 99 pour 99 secondes La dur e 00 correspond au fonctionnement bistable du relais 2 La led verte s allume 1s pour confirmer la programmation 5 Tapez 3 pour la temporisation du relais 3 La led verte s allume 1s Tapez la dur e de c
9. the audible signal The audible signal is always audible during programming It is also audible on a command to open following the recognition of a code By default when the opening code is entered no key beep is audible It is possible to authorise key beeps by proceeding as follows 1 Enter the master code twice For the first use the factory master code is 1 2 3 4 5 Red LED lights on to confirm entry in programming mode User code table 18 User location cdvi com cdvigroup com 2 Press One beep is emitted Press to disable the audible signal during a keypress Press 1 to enable the audible signal during a keypress beep is emitted to confirm the new setting 4 Press to exit from the programming mode Two beeps sound are emitted to confirm the return to the normal operating mode User f Name First name location INSTALLATION MANUAL CBB Self contained Keypad braille keys User location User location cdvi com cdvigroup com 19 Enter the master code twice 2 x beep red LED s on Timeout Code lenght Master code Green LED on for 1 sec 1 x beep Green LED on for 1 sec 1 x beep Green LED on for 1 sec 1 x beep Green LED on for 1 sec 1 x beep Green LED on for 1 sec 1 x beep Green LED on for 1 sec 1 x beep 01 99 sec 01 99 sec 01
10. tre compos s de 4 5 ou 6 termes Le code maitre ne peut pas tre utilis comme code d ouverture Les codesO000000u00000 ou 0 servent annuler code existant et ne peuvent donc A Remise z ro de la m moire OU 1 Coupez l alimentation Positionnez un cavalier en P2 1 Tapez 2 fois le code ma tre Pour la premi re utilisation le code ma tre usine est 12345 2 La led rouge s allume pour confirmer l entr e en programmation 2 Puis tapez La led verte s allume 1s Tapez et pour valider la remise 3 z ro La led verte s allume Attendre qu elle s teigne pas servir comme code d ouverture de porte Commande par bouton poussoir Le raccordement du bouton poussoir P1 est pr vu pour commander le relais 1 le mode et la temporisation sont programmables Le contact horloge H1 permet l utilisation de la touche 0 comme bouton ext rieur Si le contact horloge est ouvert la touche 0 est utilis e comme une touche habituelle Si le contact horloge est ferm la touche 0 est utilis e pour l ouverture libre Consommation sans les l ments de commande Avec les 2 relais command s En 12 V AC Au repos 20 mA avec les 3 relais command s 100 mA max En 24 V AC Au repos 10 mA avec les 3 relais command s 50 mA max R tablir l alimentation La led verte s allume Attendre quelques secondes un bip est mis La led verte s tein
11. tre usine par celui de votre choix Alimentation s par e pour les l ments Lors du changement du code ma tre usine de commande et de la cr ation des codes utilisateurs vitez les codes trop simples ex les suites 3 4 5 6 7 Montage Afin d optimiser la fixation du CBB Recommandations d installation et de pr venir les tentatives d arrachage Pour s curiser l installation n oubliez pas de placer privil giez les surfaces planes la varistance sur le syst me de verrouillage en parall le au niveau de l alimentation cdvi com 2 cdvigroup com MANUEL D INSTALLATION FR CBB Digicode gr e Touches braille 3 KIT DE MONTAGE Vis DIAX Cl male coud e t te frais e pour vis DIAX palis M5x16 Outil ODIAX 1 1 1 4 MONTAGE Apr s avoir v rifi que le kit de montage est complet vous allez pouvoir proc der a l installation finale du produit R unissez le mat riel appropri Per euse tournevis m tre et suivez les recommandations de montage du CBB A l aide du CBB prenez les marques Fixez le fond du CBB sur le support Bloquez le CBB sur son support et percez les 4 trous de fixation ainsi de votre choix passez le c ble par l interm diaire de la vis DIAX t te que l ouverture pour le passage lectrique du CBB dans son ouverture frais e et de son outil sp cifique du c ble lectrique destin au clavier cl m le coud e cdvi com cdvigroup co
12. you have all the appropriate tools drill screw drivers and a meter tape and follow the mounting instructions of for the CBB keypad Take the flush casing to measure and Mount the back casing of the CBB Finally Mount the CBB with the DIAX mark the mounting holes Then drillthe 4 the electric cable from the wiring screw mounting holes and the wiring access area access area cdvi com cdvigroup com 13 5 WIRING DIAGRAM ined Keypad braille keys Magnetic lock or fa Strike P2 Reset H1 Fail secure locking device v Varistor P3 Enable disable user code modification by user Terminals Description Input voltage 12V to 24V ac or 12V to 48V dc Input voltage 12V to 24V ac or 12V to 48V dc Relay 1 Request to Exit input Common input for P1 and H1 Clock switch Relay 2 N C contact Input Voltage 12V to 24V ac 230V or 12V to 48V dc Input Voltage 12V to 24V ac 230V or 12V to 48V dc ST1 Audible feedback jumper Remove to disable audible feedback This product is supplied with a varistor It should be mounted on the terminal of electric release electromagnetic lock solenoid bolt etc controlled by the device If this device controls more than one electronic release then each lock should be fitted with a varistor The varistor controls the overload produced by the strike coil back emf It is recommended to use a separate power supply when usi
13. e green LED lights on for 1 second to confirm the new master code 3 Press to exit from the programming mode The red LED lights off to confirm that the keypad is in stand by operating mode cdvi com 16 cdvigroup com D Adding changing or deleting a user code Relay 1 Group 1 From location 00 to location 59 Relay 2 Group 2 From location 60 to location 79 Relay 3 Group 3 From location 80 to location 99 Master code Master code RED Led rill i gt rights on 1 Enter the master code twice For the first use the factory master code is 1234 5 The red LED s light on to confirm entry in programming mode 2 Enter the user location to be programmed from 00 to 99 If the location is free the green LED s light on during 1 second enter the 4 5 or 6 digits of the code If the location is occupied the red LED s flashes 4 times Enter the 4 5 or 6 digits of the code orenter 0000000r000000r0000 to cancel the existing code If the Pin code is already programmed or is identical to the master code then 4 beeps are emitted Codes 0000000or00000 or O serve to cancel an existing code and hence cannot be used as an usual code 3 Press to exit from the programming mode The red LED lights off to confirm that the keypad is in stand by operating mode E Time outputs 1 Enter the master code twice For the first use the factory master code is
14. e operated from the 0 digit a Dimensions L x W x D 125 x 100 x 65 mm Input voltage 12 V to 24 V ac 12 V to 48 V dc a Consumption 140 mA were T SE C Certification CE 9 20 C to 50 C FE Certification FCC CFR 47 part 15 compliance e JE M PS 189 8 S lgicoda Lx HIGH RESISTANCE 10 VANDALISM L NO xX Recommended power supplies ARD12 BS60 2 REMINDERS AND RECOMMENDATIONS Recommended power supplies There are two suitable power supplies for the enclosed keypad ARD12 and BS60 Separate power supply for control components Mounting recommendations Mount the keypad on a flat surface to avoid any vandalism and to ensure the best mounting cdvi com 12 cdvigroup com Security advice For security advice reasons change the factory default master code When selecting a master code and user code avoid simple codes example 3 45 6 7 Back EMF protection To secure the system from back electromagnetic fields do not forget to insert the varistor in parallel with the lock J INSTALLATION MANUAL EN CBB Self contained Keypad braille keys 3 MOUNTING KIT DIAX screw pe ce 5 680K M5x16 ODIAX tool Varistor 1 1 1 4 MOUNTING INSTRUCTIONS Once you have made sure that the mounting kit is complete and that you prepared the cables of the CBB keypad then you can proceed and mount the product Make sure that
15. emove the jumper The master code is again 123456 in 6 digits 1 2 3 4 5 in 5 digits or 1 23 4 in 4 digits G Changing the code by the user To enable the function programming the code by the user place jumper on P3 Remove the jumper to disable the function 1 Enter the old user code The relay is activated Green LED lights on 2 Enter the 2 digit sub master code The red LED lights on to authorise the modification 3 Enter the new user code Green LED lights on for 1 second to confirm the new code The red LED lights off Check the new user code to be sure of the modification Setting a sub master code 1 Enter the master code twice For the first use the factory master code is 12345 The red LED s light on to confirm entry in programming mode 2 Press 7 to input modification digits for group 1 user codes Green LED lights on for 1 second Enter the two digits of the modifications 3 Press 8 to input modification digits for group 2 user codes Green LED lights on for 1 second Enter the two digits of the modifications 4 Press 9 to input modification digits for group 3 user codes Green LED lights on for 1 second Enter the two digits of the modifications 5 Press to exit from the programming mode The red LED lights off to confirm that the keypad is in stand by operating mode cdvi com cdvigroup com 17 I tained Keypad braille keys Programming
16. es pendant la composition de la programmation du code d ouverture Un bip est mis La led rouge s teint pour confirmer pour confirmer la programmation le retour au mode normal de fonctionnement 3 Tapez pour sortir I Programmation du signal sonore de la programmation Deux bips sont mis pour confirmer Le signal sonore est toujours audible le retour au mode normal en programmation Il en est de m me de fonctionnement lors de la commande d ouverture suite la reconnaissance d un code Ci joint un tableau r capitulatif qui vous servira indiquer le code attribu chaque utilisateur cdvi com 8 cdvigroup com MANUEL D INSTALLATION CBB Digicode avec lectronique int gr e Touches braille Pr nom Nom E i a Nom cdvi com cdvigroup com 9 e avec lectronique int gr e Touches braille 7 SYNTH SE DE PROGRAMMATION Tapez 2 fois le code maitre 2 bips led rouge allum e Temporisation Temporisation Temporisation Temporisation Nombre E Code maitre clavier relais 1 relais 2 relais 3 de termes led verte allum e is 1 x bip led verte allum e 1s 1 x bip led verte allum e is 1 x bip led verte allum e 1s 1 x bip led verte allum e 1s 1 x bip led verte allum e 1s 1 x bip 01 99 sec 01 99 sec 01 99 sec 4 5 ou 6 00 bistable 00 bistable 00 bistable chiffres
17. jumper Reset to default master error code and delete all user codes Consumption Digits used and opening codes All the keypad keys can be used to program a code P3 jumper User code modification by user active without the control elements With the 2 relays controlled Default values The master code and the ECHO In 12 V ac 20 mA codes be of 4 or 5 or 6 digit in stand by 100 mA max _ Tix in length f mia ue pg The master code CAN NOT be used Gaia ay eee Wetec Code length 5 digits as a user code In 24 V ac 10 mA in stand by Codes000000 00000 and O O O O can only be used to delete a user code To delete a User Code enter the user number Master Code 123 4 5 Programming security lag 120s 50 mA max with 3 relays activated A Resetting the memory 5 R 1 Enter the master code twice For the first use the factory master code is 1 2 3 4 5 Red LED lights on to confirm 1 Turn off the power supply Place a jumper at P2 2 Turn the power supply on again entry in programming mode Green LED lights on Wait a few seconds a beep is emitted 2 Then press 6 Green LED lights off Green LED lights on for 1 second Press k and to confirm the resetting Green LED lights on Wait for the lighting to go off The master code is 1 2 3 4 5 again and all the codes have been erased The keypad is reinitialised Red led lights on then lights off
18. m 3 avec lectronique int gr e Touches braille 5 RACCORDEMENT Bornier Correspondance Alimentation 12 V 24 V AC ou 12 V 48V DC Alimentation 12 V 24 V AC ou 12 V 48V DC Ea Bouton poussoir de sortie pou fem F Entr e horloge Contact travail du relais 2 o Commun du relais 2 E Contact travail du relais 1 E Commun du relais 1 E Contact repos du relais 1 Contact travail du relais 3 Commun du relais 3 a D s S m H1 Alimentation r 12V 24V AC 230V J ou 12V 48V DC P i D 8 ES 5 e Alimentation 12V 24V AC 230V ou 12V 48V DC v Varistance P2 Remise z ro P3 Modification codes utilisateur ST1 Cavalier pour le buzzer A enlever pour supprimer le signal sonore Ce produit est livr avec une varistance Celle ci doit tre mont e directement sur les bornes de la g che ventouse command e par l quipement Si l appareil fonctionne avec plusieurs g ches chacune doit tre quip e de varistance La varistance limite les surtensions provoqu es par le bobinage de la g che effet de self Dans le cas o la ventouse utilis e est du type Shear Lock celle ci doit tre aliment e par une alimentation ind pendante du CBB cdvi com 4 cdvigroup com MANUEL D INSTALLATION CBB Digicode avec lectronique int gr e Touches braille 6 PROGRAMMATION Description
19. ng a Shear Lock Magnet 14 cdvi com cdvigroup com INSTALLATION MANUAL Self contained Keypad braille keys 6 PROGRAMMING Description Sub master code for user code location number then enter 12V to 24V ac power supply modification User Group 1 O O O O if the code length or 12V to 48V dc and is in 4 digit format enter 00000 12 key keypad with braille keys Sub master code for user code if the code length is in 5 digit format Visual feedback Green and Red modification User Group 2 1 and 3 LED s Sub master code for user code Control by push button Non volatile EPROM memory modification User Group 3 4 and 6 The connection of push button P1 100 programmable codes Red LED light on when keypad is intended for controlling relay 1 in 4 5 or 6 digits is powered the mode and the time lag 1 relay output N O contact can be programmed 6A 250V Audible signal correspondence Hi input can be used with a timer 2 relay outputs N O and N C 1 short beep Keypad powered to allow free access by pressing contact 6A 250V 1 long beep Programming on the O digit key If the timer Master code programmable validated and relay activated contact is open then the free in 4 5 or 6 digits 2 short beeps Enter or Exit access is deactivated If the timer Warning buzzer from programming is closed then the free access 1 request to exit input 4 short beeps data computing is activated P2
20. ogrammation des termes de modifications 1 Tapez 2 fois le code maitre Pour la premi re utilisation le code maitre usine est 12345 La led rouge s allume pour confirmer l entr e en programmation 2 Tapez 7 pour la saisie des termes de modifications des codes utilisateurs du groupe 1 La led verte s allume 1s Tapez les deux termes de modifications La led verte s allume 1s pour confirmer la programmation cdvi com cdvigroup com 7 avec lectronique int gr e Touches braille 3 Tapez 8 pour la saisie des termes Par d faut lors de la composition du code de modifications des codes utilisateurs d ouverture aucun bip touche n est audible du groupe 2 Il est possible d autoriser les bips touches La led verte s allume 1s en faisant comme suit Tapez les deux termes de modifications La led verte s allume 1s pour confirmer 1 Tapez 2 fois le code maitre la programmation Pour la premi re utilisation le code ma tre usine est 1 23 4 5 4 Tapez 9 pour la saisie des termes Deux bips sont mis pour confirmer de modifications des codes utilisateurs l entr e en programmation du groupe 3 La led verte s allume 1s 2 Tapez Tapez les deux termes de modifications Un bip est mis La led verte s allume 1s pour confirmer Tapez 0 pour supprimer les bips touches la programmation pendant la composition du code d ouverture Tapez 1 pour autoriser 5 Tapez pour sortir les bips touch
21. ommande en secondes 01 pour 1 seconde jusqu 99 pour 99 secondes La dur e 00 correspond au fonctionnement bistable du relais 2 La led verte s allume 1s pour confirmer la programmation 6 Pour sortir de la programmation tapez La led rouge s teint pour confirmer le retour au mode normal de fonctionnement 4 clignotements de la led rouge indiquent une erreur de saisie F Remise z ro du code maitre G H En fonctionnement normal positionnez un cavalier en P2 La led verte s allume Un bip est mis Attendre que la led verte s teigne Enlevez le cavalier Le code maitre est de nouveau 123 4 5 6 en 6 termes 12345enb5termesou1234 en 4 termes Changement du code d entr e par l utilisateur L autorisation de changement de code par l utilisateur est d termin e par le positionnement du cavalier P3 pas de cavalier pour interdire le changement de code Si le cavalier est en place le changement de code est autoris 1 Composez le code utilis actuellement Le relais d ouverture est command La led verte s allume 2 Tapez imm diatement les 2 termes du code de modification La led rouge s allume pour autoriser le changement 3 Composez le nouveau code d ouverture La led verte s allume 1s confirmant la validation du nouveau code et le retour un fonctionnement normal La led rouge s teint V rifiez la m morisation du nouveau code en le composant Pr
22. t Enlevez le cavalier P2 Le code maitre est de nouveau 123 45 et tous les codes sont effac s Les valeurs par d faut sont r tablies Le code maitre est de nouveau 1 2 4 5 et tous les codes sont effac s Le clavier est r initialis les leds rouges restent allum es puis s teignent Le clavier est sorti de programmation et les valeurs par d faut sont r tablies cdvi com cdvigroup com 5 B Programmation du nombre de termes 1 Tapez 2 fois le code ma tre Pour la premi re utilisation le code maitre usine est 12345 La led rouge s allume pour confirmer l entr e en programmation 2 Tapez 4 pour la saisie du nombre de termes des codes La led verte s allume 1s Tapez 4 5 ou 6 pour le nombre de termes La led verte s allume 1s pour confirmer la programmation 3 Tapez 5 pour changer le code maitre La led verte s allume 1s Tapez les 4 5 ou 6 termes du nouveau code maitre La led verte s allume 1s pour confirmer la programmation 4 Tapez pour sortir de la programmation La led rouge s teint pour confirmer le retour au mode normal de fonctionnement 4 clignotements de la led rouge indiquent une erreur de saisie Code maitre ou code utilisateur 1 2 3 6 9 Passage 4 termes Tapez 236 9 Passage 6 termes Tapez0 12369 Il est conseill de programmer les codes en 6 termes puis de modifier le nombre de termes C Programmation du code maitre
23. t document photos dessins caract ristiques varier et sont susceptibles de modifications sans notification pr alable CDVI Headquarters Si ge social CDVI CDVI FRANCE SWITZERLAND MAROC Phone 33 0 1 48 91 01 02 Phone 41 0 21 882 18 41 Phone 212 0 5 22 48 09 40 Fax 33 0 1 48 91 21 21 Fax 41 0 21 882 18 42 Fax 212 0 5 22 48 34 69 CDVI AMERICAS CDVI CDVI SWEDEN CANADA USA CHINA SWEDEN DANEMARK NORWAY FINLAND Phone 1 450 682 7945 Phone 86 0 10 87664065 Phone 46 0 31 760 19 30 Fax 1 450 682 9590 Fax 86 0 10 87664165 Fax 46 0 31 7 48 09 30 CDVI BENELUX CDVI IB RICA oj P 4 BELGIUM NETHERLAND LUXEMBOURG SPAIN PORTUGAL UNITED KINGDOM IRELAND Phone 32 0 56 62 02 50 Phone 34 0 935 390 966 Phone 44 0 1628 531300 Fax 32 0 56 62 0255 Fax 34 0 935 390 970 Fax 44 0 1628 531003 CDVI CDVI DIGIT TAIWAN ITALIA FRANCE Phone 886 0 42471 2188 Phone 39 0331 97 38 08 Phone 33 0 1 41 71 06 85 Fax 886 0 42471 2131 Fax 39 0331 97 39 70 Fax 33 0 1 41 71 06 86 cdvigroup c

Download Pdf Manuals

image

Related Search

Related Contents

MINI SPY CAMERA  Defort DBC-12  Conceptronic Storage box 5.25 inch  PDF manual - Ocean Drilling Program  HD6 Quuick Start Guide (French)  Acoplador de dispositivos de campo Zona 1 Ex e  試験問題 - 日本バーチャルリアリティ学会  BR50 User Manual 2-2015 V-4  Roland Roland EM-15 OR Oriental Creative Keyboard Computer Keyboard User Manual  Alarma E39 - BMW Carx Spain  

Copyright © All rights reserved.
Failed to retrieve file