User's Manual Remote Management Card
Contents
1. RMCARD302 1 Remove the two retaining screws on the card without turning off the UPS 2 Uninstall the card 3 Take off the jumper on the Reset pins as illustrated The jumper is still necessary after reset please do not lose or dispose of it 4 Re install the card into the expansion port 5 Wait until the Green LED is flashing the frequency of the ON OFF flashing is one second 6 Uninstall the card again 7 Place the jumper back onto the Reset pins 8 Install card into the expansion port again 9 Tighten the retaining screws 24 CyberPower Remote Management System Firmware Upgrade By upgrading the Firmware you can obtain both the new features and updates improvements to existing functionality There are two files to update in order to upgrade the firmware version RMCARD202 RMCARD203 upgrade files A cossnmpfw_XXX bin B cpssnmpdata_XXX bin RMCARD302 upgrade files A cpsrm302afw XXX bin B cpsrm302adata_XXX bin Use the following steps to upgrade the firmware Download the latest Firmware Extract the file to C Open a command prompt window Login to the CyberPower Remote Management Card with FTP command type ftp ftp gt open To current ip of RMCARD port EX To 192 168 22 126 21 Input USER NAME and PASSWORD same as the administrator account in Web interface default cyber cyber 5 Upgrade the file A type ftp gt bin ftp gt put A RMCARD202 for ex put cossnmpfw_XXX bin 6 Upg
2. Set the frequency to record the status data A smaller interval will provide more frequent Recording Interval recordings but maintain them for a shorter period A larger interval will provide less frequent recordings but maintain them for a longer period Clear All Clear the existing status records CyberPower Remote Management System 7 The remaining recordable time base on the recording Remaining Time hier al Save Status Records Save the status records as a txt file System gt General gt User Account This page is used to configure the login account ie The administrator can access full function including Administrator enable disable the Viewer account The viewer can access the read function but can not Viewer control or change any settings This IP setting is to set the allowable IP addresses Users who log in as Admin Viewer can access Manager IP RMCARD web pages if its IP Address is in one of Admin Viewer Manager IPs If you want to access RMCARD from any IP address you can set one of them as 0 0 0 0 or 255 255 255 255 Change Administrator account e Enter User Name e Enter Current Password for Authentication e Set the Manager IP optional e Enter New Password e Enter Confirm Password e Click Apply Change Viewer account e Select Allow Access to enable the Viewer account e Enter the User Name e Set the Manager IP optional e Enter New Password e Enter Confirm Password e Click
3. Power Device Network Utility program Under All Programs select CyberPower Power Device Network Utility 3 The main dialog of the Power Device Network Utility Tool program is shown in Figure 1 The configuration tool will display all CyberPower Remote Management Cards of present on the same network The Refresh button is used to search the entire local network for Remote Management Cards CyberPower Remote Management System TT Power Device Network Utility File Tools Help Power Devices MAC Address IP Address Subnet Mask Gateway DHCP Name Location UpTime Version Ep 00 0C 15 C0 34 64 192168 22225 255 255 255 0 192 168 22 254 NIA RMCARD201 Server Room 18m 55s 3 0 5 CETTE EEE EEE EEE AA Figure 1 The main window of the Power Device Network Utility program 4 Select the Remote Management Card you are setting up Click on the Tools menu and select Device Setup or double click the Remote Management Card you want to configure 5 You can modify the IP Address Subnet Mask and Gateway address for the Device MAC Address listed in the Device Network Settings window as shown in Figure 2 The default IP Address is 192 168 20 177 and the default Subnet Mask is 255 255 255 0 Device Network Settings Device MAC Address 00 0C 15 C0 34 64 Using DHCP OYes No IP Address 192 168 22 226 Subnet Mask 255 255 255 0 Gateway 4192 168 22 254 Cancel Figure 2 The set
4. Service and configures the TCP IP port that Telnet uses to communicate 23 by default System gt Network Service gt FTP Service Allows users to Enable Disable the FTP server service and configure the TCP IP port of the FTP server 21 by default System gt About Displays vital information for the Remote Management Card ee Model Name Model name of the Remote Management Card The version number of the current firmware installed Firmware Version on Remote Management Card Firmware Updated Date The date the firmware was last updated The hardware version of the Remote Management Hardware Version Card MAC address of the Remote Management Card MAC Address Note the MAC address is also listed on the top of the Remote Management Card Click Save to save the configuration to local PC The Save Configuration DS text file will have a default format of CyberPower Remote Management System Use this function to restore a configuration that has Restore Configuration been saved earlier Click Browse to the location of the saved configuration file and click Submit Reset to Default Setting Recover from a Lost Password To reset the CyberPower Remote Management Card to its default setting including WEB log in user name and password please use the following steps nu ETIS pi RESET RESET RMCARD202 RMCARD203 ol RESET RU
5. 123 bytes to the IP A Type in ping 192 168 20 240 I 123 then press Enter B Ifthe replies are received your computer can communicate with the IP address To select an IP address for the Remote Management Card please refer to Appendix 1 CyberPower Remote Management System WEB INTERFACE Login Account There are two types of user account Administrator default username cyber default password cyber Viewer default username device default password cyber The Administrator can access and control all functions including enable disable of the Viewer account The Viewer s access possesses read permissions for all functions but cannot control or change any settings Web Content Summary Provides an overview of the system operation and the items that are auto refreshed however different model of RMCARD may have different items displayed Coran Condon Display the current operating condition of UPS and environment sensor UPS Status Battery Capacity The percentage of the current UPS battery capacity in a graph bot The load of UPS as a percentage of available Watts in a graph Remaining Runtime How long the UPS can support its load by battery power System Data The name of the equipment The Location of the equipment The person to contact about this equipment How long the system has been working continuously The current temperature of the environment in a graph CyberPower Remote Management System The
6. Apply System gt General gt Date amp Time Current Settings Displays the current date and time on the card and allows users to set the date and time To set the date and time users can choose to set manually or by using the NTP Network Time Protocol server System Time Configuration e Using NTP server Enter the IP address domain name of NTP servers choose the time zone and set the frequency to update the date and time from NTP server Choose Update right now to update immediately 19 CyberPower Remote Management System e Manual Setup Enter the date and time in the designated format System gt General gt Identification Assigns the system s name contact and location enn Where the power equipment is located The person to contact about this equipment System gt General gt Security Sets for security setting ee The period in minutes that the system waits before Timeout auto logging off Sadish Phrase The Authentication Phrase used to communicate with PowerPanel Business Edition Client System gt Notifications gt Event Action Displays the event actions for each event Users can click on the event to modify its action When a specific event happens the user can be notified by the corresponding method according to this list Log Record the event in the Event Logs E mail Send an email to a specific user An available SMTP server is necessary Trap ASNMP trap sent t
7. IP of DNS from the DHCP Manual Enter the TCP IP settings directly and click Apply System gt Network Service gt HTTP Service Selects Enable to allow access to the HTTP Service and configures the TCP IP port of the Hypertext Transfer Protocol HTTP 80 by default System gt Network Service gt SNMP Service Allows users to select the NMS defined by the IP settings that can use the channel to control the system data access through SNMP tem ten Allow Access Set the SNMP service to either Enable or Disable The name used to access this community by a Network Management System NMS The field must be 1 to 15 characters length The IP address or IP address mask can be accessed by NMS A specific IP address allows access only by Community Name CyberPower Remote Management System the NMS with the specified IP Address The 255 is regarded as the mask and the rules list as follows e 192 168 20 255 Access only by an NMS on the 192 168 20 segment 192 255 255 255 Access only by an NMS on the 192 segment 0 0 0 0 the default setting or 255 255 255 255 Access by any NMS on any segment The allowable action for the NMS through the Access Type j community and IP Read Only Gets at anytime but cannot SETS Write Read Gets at anytime SETS anytime unless someone is logged in the Web interface Forbidden No GETS or SETS System gt Network Service gt Telnet Service Selects Enable to allow access to the Telnet
8. current humidity of the environment in a graph C The name of the environment sensor The location of the environment sensor List the latest 5 events that occurred recently UPS Following items can be displayed configured through the UPS web interface however different UPS may have different items displayed configured UPS gt Status Displays the basic information about the current UPS status and the items that are auto refreshed Item Definition Input Status Display the present status of the utility power supplied to the UPS Voltage The current input voltage of the utility power The current frequency of the utility power supplied to Frequency B q y yp pp Output Status Display the present status of the output power the UPS is supplying to connected equipment Voltage The output voltage the UPS is supplying to the j connected equipment Frequency The output frequency the UPS is supplying to the connected equipment The percentage of the total UPS capacity that is Load being supplied to the connected equipment This is displayed as Watts in some UPS models Non Critical Bank Display the present status of the NCL outlet Battery Status Display the present status of the battery packs Remaining Capacity The percentage of the current UPS battery capacity Remaining Runtime System Temperature Information Model Name Voltage Rating Working Frequency Power Rating Current Rating Load Power Bat
9. the Start button to initiate a runtime calibration Click the Cancel button to stop the runtime calibration The result will be reported after a calibration is finished or canceled e Estimated Runtime The estimated runtime of the batteries e Last Calibration Elapsed Time The elapsed time of last Runtime calibration e Last Calibration Result The results of the last runtime calibration Passed The runtime calibration is completed and the batteries are good None The UPS has never performed a runtime calibration Failed The UPS fails during the runtime calibration Canceled The calibration was interrupted e Last Calibration Date The last date performing the runtime calibration UPS gt Schedule Sets the UPS to automatically shutdown and restart at scheduled times one time per day per week The Schedule page manages scheduled shutdowns and lists all configured schedules Each schedule row displays the details of when the schedule will take effect and when to perform it CyberPower Remote Management System One Time The user may set a specific date and time for the UPS shutdown Per Day Set a specific time of the day for the UPS shutdown Per Week Set a specific day and time of the week for the UPS shutdown 1 Click One Time Per Day or Per Week option and Click Next gt gt Enter the date and time to shut down the UPS Select Never Immediately or the date and time for the UPS to restore power Select th
10. CyberPower yoerr Quality Value User s Manual Remote Management Card RMCARD202 RMCARD203 RMCARD302 Intelligent Remote Management Card allows a UPS system environment sensor to be managed monitored and configured Version 1 4 CyberPower Remote Management System TABLE OF CONTENTS IDTOUUCHOMSS SES E al Nu 1 Tastan oi ide snai aa E nt ns 3 WEO TIE ICE eo RS de 8 Reset to Default Setting Recover from a Lost Password 24 Pirmware COT 6 RE SR oS 25 Trouble SOON dns etes 26 PA 0 DC COL PO Re das dusituledad saamunseamned N A 27 INTRODUCTION Overview The CyberPower Remote Management Card allows for remote monitoring and control of a UPS attached to a network After installing the hardware and configuring an IP address the user can access monitor and control the UPS from anywhere in the world Simply use a web browser such as Internet Explorer or Firefox to access your UPS Servers and workstations can be protected by the UPS utilizing the PowerPanel Business Edition Client version to gracefully shutdown when signaled by the Remote Management Card Features Real time UPS monitoring Remote management and configuration of UPS via Web Browser or NMS Auto shutdown to protect servers workstations from data lost due to power failure Schedule shutdown start up reboot of the UPS via remote control Event logging to trace UPS operational history Data logging for analyzing power conditions Event notification via
11. T 21 CyberPower Remote Management System the Agent Client sends a notification to the SMS provider This specification from a SMS provider is required before using the E mail to deliver the messages to SMS providers Select the Using E mail option in the Service Provider field Insert E PHONE NUMBER as recipient s mobile phone number and the E PHONE MESSAGE as event message describe in the specification Fill in the Recipient s Address Subject and Content The expressions will be replaced by the relevant content before the Agent Client sends a notification to the SMS provider Service provider accepts E mail SMTP System gt Notifications gt SMS Recipients Users can set up to 10 mobile phone numbers as SMS recipients The Recipients will receive a short message notification when events occur To add a new recipient click New Recipient To modify or delete an existing Recipient click the mobile number or Name of that recipient To test SMS settings click TEST button and see if the test message is correctly received System gt Network Service gt TCP IP Displays the current TCP IP settings IP address Subnet Mask Gateway and DNS server This also provides the function to obtain TCP IP settings from the DHCP server DHCP Select the Enable DHCP option and click Apply to get IP address Subnet Mask and Gateway by DHCP Select the Obtain DNS Address from DHCP option and click Apply to get the
12. after represents any number between 1 and 255 Similarly if the Subnet Mask is 255 255 0 0 the IP Address for Remote Management Card could be set up as 192 168 to reach the same subnet with the computer To verify there is no other equipment connected to the network using the same IP Address run Ping 192 168 20 240 at the DOS Mode prompt when the IP Address you would like to set is 192 168 20 240 If the response is presented as below the IP address is most likely not used and may be available for the CyberPower Remote Management Card Pinging 192 168 20 240 with 32 bytes of data Request timed out Request timed out Request timed out Request timed out 27 CyberPower Remote Management System If the response is shown as below the IP address is in use Try another IP address until an available address is found Pinging 192 168 20 240 with 32 bytes of data Reply from 192 168 20 240 bytes 32 time lt 10ms TTL 64 Reply from 192 168 20 240 bytes 32 time lt 10ms TTL 64 Reply from 192 168 20 240 bytes 32 time lt 10ms TTL 64 Reply from 192 168 20 240 bytes 32 time lt 10ms TTL 64 28 CyberPower Remote Management System CyberPower Reliability Quality Value CyberPower North America CyberPower Systems USA Inc 4241 12th Avenue East Suite 400 Shakopee MN 55379 Phone 952 403 9500 Toll free 877 297 6937 Website www CPSww com E mail tech cpsww com CyberPower Europe CyberPower Systems Inc Websit
13. agement System Appendix 1 IP Address Settings for the CyberPower Remote Management Card Overview All devices on a computer network need to have an IP address Each device s IP address is unique The same address cannot be used twice In order to assign an IP address to the CyberPower Remote Management Card you must determine the range of the available IP addresses and then choose an unused IP address to assign to the Remote Management Card PLEASE NOTE You may need to contact your network administrator to obtain an available IP address Procedures to find an IP address 1 Locate the subnet of CyberPower Remote Management Card One way to determine the range of possible IP addresses is to view the network configuration on a workstation Click on Start and select Run Type command into the open box and click OK At the command prompt type ipconfig all and press Enter The computer will display network information as listed below Ethernet adapter Connection specific DNS Suffix xxxx com Description D Link DE220 ISA PnP LAN adapter Physical Address 1 00 80 C8 DA 7A CO 168 95 1 1 Select an IP Address for CyberPower Remote Management Card Verify the IP Addresses for the computer and the Remote Management Card belong to the same subnet Refer to the above network information the possible IP Address for the Remote Management Card could be 192 168 20 here
14. e www cpsww eu E mail sales cpsww eu Cyber Power Systems France Z I Saint S verin 28220 CLOYES sur le Loir France T l 33 0 2 37 98 61 50 E mail sales cpsww com fr 29
15. e bank to be controlled and click Shutdown Clients to set all clients to perform a graceful shutdown You can enter a comment for this Schedule 2 Click Apply to add the item to the Schedule Click Reset to remove the item from the Schedule 3 Applied settings are listed in Schedule menu UPS gt Wake on Lan This function is used to wake the PC through the network Make sure the PC hardware has such function supported and configures as Enable under BIOS Enter the IP address of that PC when it is on and the system will search its MAC accordingly The maximum number of IP that can be set is 50 UPS gt PowerPanel Clients Displays the Information of connected PPBE PowerPanel Business Edition Clients The connection is executed by PPBE Clients and the listed clients will be removed if disconnected for 1 hour Envir Following items can be displayed configured through the Envir web interface RMCARD 203 only Envir gt Status Displays the basic information of the environment sensor and connected devices Item Definition Information Name The name of the environment sensor Location The location of the environment sensor Temperature Current Value The current temperature of the environment l The highest temperature as well as the time of Maximum occurrence detected by the environment sensor E The lowest temperature as well as the time of Minimum l occurrence detected by the environment sensor Humidity C
16. ef description of each event along with the date and time stamp Logs gt Status Records This page is used to view the logs of the UPS status and environment status however different product may have different items displayed All items have the same definition as they are in the UPS status or environment status Input min V The minimum input voltage of the utility power from the previous record Input max V The maximum input voltage of the utility power from the previous record Input Hz The current frequency of the utility power supplied to the UPS Output V The output voltage of the UPS supplying to the connected equipment Output Hz The output frequency of the UPS supplying to the connected equipment Load The percentage of the total UPS power load supplying to the connected equipment Capacity The percentage of the current UPS battery capacity Remaining Runtime How long the UPS can support its load under battery mode Temperature The current temperature of the environment Humidity The current humidity of the environment Logs gt Maintenance This page is used to maintain Event Logs and Status Records The application provides information on how many events have been recorded before it is full en Clear All Clear the existing event logs The Number of Events The number of existing event logs the max number of event logs Save Event Logs Save the existing event logs as a txt file
17. email and SNMP traps Support Environment sensor management RMCARD203 Support TCP IP UDP SNMP HTTP NTP DNS SMTP protocol SNMP MIB provided Quick installation and user friendly interface User upgradeable firmware via FTP MD5 Security management provided System Requirements A computer with a Windows or Linux Operating System for optional PowerPanel Business Edition Client An Ethernet connection to an existing network NMS Network Management Station compliant with SNMP for optional NUS management CyberPower Remote Management System Application CyberPower Remote Management Card Remote NMS Web Browser Network Cables Server Protected by Server Protected by Workstation Protected by PowerPanel Buiness PowerPanel Buiness PowerPanel Buiness Edition Edition Client version Edition Client version Client version Unpacking Inspect the Remote Management Card upon receipt The package should contain the following e CyberPower Remote Management Card e PowerPanel Business Edition CD with software and user s manual CyberPower Remote Management System INSTALLATION GUIDE Step 1 Hardware Installation Internal smart slot Remote Management Card 1 Turn off the UPS before removing the expansion port cover on the UPS Remove the two retaining screws from the expansion port cover and remove the cover Insert the CyberPower Remote Management Card into the expansion port Re install and tighten the retaining screw
18. n range of the frequency tolerance the UPS will enter Bypass mode High Low Bypass Voltage Power Restore Recharged Delay Recharged Capacity Returned Delay Low Battery Threshold External Battery Pack CyberPower Remote Management System Otherwise the UPS will stop supplying output power Check Volt Only Only if the utility voltage is in the range of the voltage thresholds the UPS will enter Bypass mode Otherwise the UPS will stop supplying output power When the UPS fault or overload occurs the UPS will determine whether to enter Bypass mode according to the range of thresholds of utility voltage If the utility voltage exceeds thresholds the UPS will be forbidden to enter Bypass mode and stop supplying output power After utility power is restored the UPS turns on automatically and supplies power to the computer If the computer BIOS is set to boot when power restores the computer will restart automatically The following settings are used to configure the UPS restore actions When utility power is restored the UPS will start to recharge after the specified delay is expired When utility power is restored the UPS will start to recharge after the specified battery Capacity is met When utility power is restored the UPS will delay the restoration of output power This option can be used to stagger the startup time of multiple UPSs to avoid overloading the utility power circuit or power source The Ret
19. nformation about the battery including the results and date of the last battery test Click the Initiate button to begin a battery test Performing a battery test is prohibited when the Frequency Working Mode option is set to fixed If performing a battery test on the fixed frequency mode a UPS fault may occur and cause the UPS to enter Bypass mode The frequency on Bypass mode may not be accepted and may damage the connected equipment The results will be reported after a battery test completes e Last Test Date The date the last battery test was performed e Last Test Result The results of the last battery test Passed The battery performs normally during the test None The UPS has never performed the battery test Failed The battery test results in failure Follow the steps below if the battery test fails Repeat the battery test and replace the batteries if the test fails again Contact CyberPower for assistance if the battery test fails after the batteries have been replaced Runtime Calibration The Runtime Calibration ensures the runtime estimate is accurate with the load and the current battery capacity The results show the runtime the results and the date of the last calibration When a runtime calibration is initiated the connected equipment will be run on battery power until the batteries are completely discharged Following the Runtime Calibration the UPS will automatically begin recharging the batteries Users can click
20. o a specific IP address SMS Send a short message to a specific mobile phone number An available SMS service provider is needed System gt Notifications gt SMTP Server After setting the proper SMTP server the UPS can send an email to users when a specific event occurs Definition Servers Pitot Name The IP or Host Name of SMTP server used to notify users by E mail senders E malAddress The context of From field shown in the e mail message sent to user Select this option if the SMTP server needs Authentication check Username used for Authentication Password used for Authentication Authentication 20 CyberPower Remote Management System System gt Notifications gt E mail Recipients Sets up to five e mail recipients in designated email address format The Recipients will receive an e mail notification when Events occur To add a new recipient click New Recipient To modify or delete an existing Recipient click the e mail address of that recipient To check if SMTP setting and the email recipients are set correctly click TEST button to check receiving status System gt Notifications gt Trap Receivers List of NMS IP as TRAP receiver and the number of receivers can be set up to 10 The receiver will receive a SNMP trap when an event occurs To add a new receiver click New Receiver To modify or delete an existing receiver click the IP address or name of that receiver To check if the traps can be recei
21. or no power Screen Saver Time event occurs during this delay the LCD screen will be turned off If this option is enabled the UPS will detect if the UPS wiring is not grounded or is reversed It is recommended to assure the UPS wiring has ground connection first This option should be enabled if the UPS wiring has ground connection Dry Relay Function Wiring Fault Detect Non Critical Outlet Bank When supplying battery power the UPS will Turn Off Threshold power off the NCL outlet if the remaining battery capacity is lower than this threshold When supplying battery power the UPS will Turn off Delay Time power off this NCL outlet after this delay time is met When utility power is restored the UPS will restore the output of the NCL outlet after the delay time is met This prevents excessive power consumption caused by all the connected equipment rebooting at the same time Turn On Delay Time CyberPower Remote Management System UPS Master Switch Switches the output power of the UPS to be on or off Item Reboot UPS Turn UPS Off UPS Sleep Cancel Switch Turn UPS On Shutdown Sleep Delay Reboot Duration Signal Clients to Shutdown Definition Turn the UPS off and back on Turn the UPS off This command is available under Utility Power Failure Mode It will make UPS under sleep mode until power is restored Cancel a pending action to turn the UPS off Turn the UPS on How long the UPS
22. rade complete type ftp gt quit 7 The system will reboot after you type quit RC NES 8 Login to the FTP again as step 4 9 Upgrade the file B type ftp gt bin ftp gt put B RMCARD202 for ex put cossnmpdata_XXX bin 10 Upgrade complete type ftp gt quit 11 The system will reboot after you type quit You can check to see if the firmware upgrade was successful by checking the Firmware version on the System gt About webpage 25 Trouble Shooting Problem Unable to configure the Management Card by method 1 or method 2 Unable to ping the Management Card Lost the user name and password CyberPower Remote Management System Solution 1 Check the LED status the normal condition is when yellow and green led are both on If green led is off gt Check the Management Card for proper seating in the UPS and the UPS power is on If yellow led is off gt Ensure the network connection is valid 2 Ensure the PC being used is on the same physical network as Remote Management Card 1 Use method 1 and method 2 to get correct an IP address for the Remote Management Card 2 If the PC being used is on a different physical network from the Remote Management Card verify the setting of subnet mask and the IP address of gateway Please refer to the Reset to Default Setting Recover from a Lost Password section of the user s manual 26 CyberPower Remote Man
23. s oar wh 7 Turn onthe UPS 1 gt s De RMCARD302 Connect the Ethernet cable to the LAN port on the CyberPower Remote Management Card To connect with the environment sensor use RJ45 Ethernet cable Plug one end into the Universal connector and the other end into the sensor RMCARD203 LINK Indicator CyberPower Ethernet connector RX TX Indicator RXTX RMCARD202 amp YY LINK Indicator Definitions for LED Indicators Link LED color Off TX RX LED color Flash Reset finished Universal connector CyberPower Remote Management System LINK Indicator _ fi TN Ethernet connector RX TX Indicator Condition The Remote Management Card is not connected to the Network or the Remote Management Card Power is off On Yellow The Remote Management Card is connected to the Network Off The Remote Management Card power is off On Green The Remote Management Card power is on Receiving transmitting data packet Step 2 Configure the IP address for the CyberPower Remote Management Card Method 1 Using the CyberPower Power Device Network Utility Tool 1 Install the CyberPower Power Device Network Utility Tool from the included CD It is located in the tools network folder of the CD Double click the Power Device Network Utility installation file Setup msi to begin the installation 2 After installation completes run the
24. tery Voltage Rating Firmware Version USB Version LCD Version Battery Replacement Date Non Critical Bank External Batteries Installation Place How long the UPS can support its load under battery CyberPower Remote Management System mode The temperature inside the UPS UPS gt Information Provides the technical specifications for the UPS Description The model name of the UPS The output voltage rating Volts of the UPS The output frequency rating Hz of the UPS The Volt Amp rating of the UPS The output current rating Amps of the UPS The power rating Watts of the UPS The DC voltage rating of the battery set The version number of the UPS firmware The version number of the UPS USB firmware The version number of the UPS LCD firmware The date that the batteries were last replaced This must be set manually and should be set after the batteries have been replaced or when the unit is first installed If this date has not been set it is recommended that this date should be set immediately The amount of the Non Critical Load The amount of the external battery packs connected to the UPS When clicking the Find it button either the alarm will beep or the indicators will flash to inform users of the location This helps users to identify a specific UPS in a multiple UPS installation CyberPower Remote Management System UPS gt Configuration Configures the parameters of the UPS S
25. ting window 6 To modify the IP Address Subnet Mask or Gateway address enter the new addresses into the corresponding fields 7 You will need to enter a User Name and Password for the Remote Management Card Figure 3 in the authentication window as shown in figure 3 Default user name cyber Default password cyber 8 CyberPower Remote Management System Authentication Enter the user name and password to save changes Username Password Figure 3 The authentication window If IP address is successfully set you will see a message that the IP set up is OK as shown in Figure 4 Network Settings Information Setup MAC 00 0C 15 C0 34 64 OK Power Device Network Information IP Address 192 168 22 226 Subnet Mask 255 255 255 0 Gateway 192 168 22 254 Figure 4 Setup IP Address successfully message CyberPower Remote Management System Method 2 Using a command prompt 1 Obtain the MAC address from the label on the Remote Management Card rear panel Each Management card has a unique MAC address 2 Use the ARP command to set the IP address Example To assign the IP Address 192 168 20 240 for the Remote Management Card which has a MAC address of 00 0C 15 00 00 01 you will type in the following command prompt from a PC connected to the same network as the Remote Management Card A Type in arp s 192 168 20 240 00 0C 15 00 00 01 then press Enter 3 Use the Ping command to assign a size of
26. upplied Power Utility Power Failure Condition High Low Input or Output Voltage Threshold Frequency Tolerance Generator Mode ECO Mode Manual Bypass Set the output voltage which is supplied to the connected equipment When the utility power voltage or output voltage according to the UPS support is higher lower than the threshold the UPS will supply battery power to the connected equipment This setting only comes into effect after a restart of the UPS Sets the acceptable range of the input frequency It will be in power failure condition if out of this tolerance Normal working mode of the UPS If the UPS uses generator as its input power this option should enable the UPS to function normally If this option is selected the UPS will be forbidden to enter Bypass mode or ECO mode to protect the powered equipment On line UPS enters Economy mode The UPS will enter Bypass mode when the input voltage frequency is in the range of thresholds Once the utility voltage frequency exceeds thresholds the UPS will supply power to its load Determine whether to allow the UPS to enter Manual Bypass mode If this option is selected the UPS will be forced to enter Bypass mode m o Qualify Bypass No Bypass If this option is selected the UPS will not enter Bypass mode and will stop supplying output power Check Volt Freq If the utility voltage is in range of the voltage thresholds and the utility frequency is i
27. urned Delay will take effect every time when the UPS restores power This also includes the scheduling and user controlling task When the UPS supplies battery power and the remaining capacity is lower than this threshold the UPS will alarm Set the amount of external battery packs This allows for an accurate runtime estimation based upon the total number of batteries C Cold Start Set the ability of the UPS to start in the absence of input power When this option is 12 CyberPower Remote Management System enabled the UPS can be turned on without input power If this option is enabled the UPS will issue Audible Alarm an audible alarm when supplying battery power or output overload This configures the power condition for the UPS dry relay to function when the selected condition occurs Refer to UPS manual for further information about advanced UPS dry relay utilization The Dry Relay Function provides following power conditions Utility Failure The utility power fails and the UPS is using battery power Low Battery The battery capacity is too low to support the connected computers to shutdown Alarm The UPS is issuing the audible alarm due to the occurrence of warning events such as overload Bypass The UPS has switched to Bypass mode due to overload or UPS fault UPS Fault The UPS could be malfunctioned due to hardware fault such as inverter fault bus fault or overheated When no UPS button is pressed
28. ved correctly click TEST button System gt Notifications gt SMS Service Short Message Service SMS is a communication service used by mobile communication systems Using standardized communication protocols will allow the interchange of short text messages between mobile devices The system provides 4 methods to users to choose how they want to send the messages Select the Clickatell option in the SMS Method field Complete all the account details including Username Password and HTTP API ID fields This specification from the SMS provider is required before using the HTTP GET method Select the Using HTTP GET option in the SMS Method field Insert the E PHONE_NUMBER as recipient s mobile phone number and the E PHONE MESSAGE as event message describe in the specification and fill in the URL field The expressions will be replaced by relevant content before the Client sends a notification to SMS provider This specification from the SMS provider is required before using the HTTP POST method to deliver messages to SMS providers Select the Using HTTP POST option in the SMS Method field Insert E PHONE NUMBER as recipient s mobile phone number and E PHONE MESSAGE as the event message describe in the specification and fill in the POST URL and POST BODY fields The expressions will be replaced by the relevant content before Service provider is Clickatell Service provider accepts HTTP GET Service provider accepts HTTP POS
29. waits before it turns off in response to a Reboot UPS Turn UPS off or UPS Sleep command After the UPS is turned off Reboot Duration defines how long the UPS waits before it turns on in response to Reboot UPS command Select this option to notify PowerPanel Business Edition Clients before UPS turning off The Shutdown Delay for the UPS can be modified to ensure a graceful shutdown UPS gt Bank Control Displays the current status of each Bank Also it provides on off control for the Non Critical Outlet Bank Outlet Index and Device Name display the device that is powered by the specific bank Non Critical Outlet Index Device Name Definition Turn the non critical bank on off immediately The index of outlet Device Name on this outlet UPS gt Diagnostics When a power failure occurs the UPS will supply battery power to all connected equipment immediately The UPS must have sufficient runtime for all connected computers to be shut down properly The UPS Diagnostics page provides the information to verify if the UPS has sufficient battery runtime for the connected computers to shutdown properly Perform a complete runtime calibration to ensure an accurate estimate of the runtime for the connected load Battery Test The Battery Test will force the UPS to switch to battery power for 10 seconds This allows the 14 CyberPower Remote Management System user to verify the battery conditions and provides i
30. yberPower Remote Management System Current Value Maximum Minimum Contact Envir gt Configuration Item Information Name Location Temperature High Threshold Low Threshold Hysteresis Rate of Change Unit Humidity High Threshold Low Threshold Hysteresis Rate of Change Contact Name The current humidity of the environment The highest humidity as well as the time of occurrence detected by the environment sensor The lowest humidity as well as the time of occurrence detected by the environment sensor Display the name and status Normal Abnormal of contacts Definition The name used to identify the environment sensor The place where the environment sensor is located Upper limit for normal temperature Lower limit for normal temperature The difference between High Low Threshold and the point where the temperature state is from abnormal to normal The rate used to define abnormal change of temperature The unit of temperature Upper limit for normal humidity Lower limit for normal temperature The difference between High Low Threshold and the point where the humidity state is from abnormal to normal The rate used to define abnormal change of humidity The name used to identify the contact 17 State CyberPower Remote Management System The state used to define normal condition of the contact Logs Event Logs Displays the list of events and a bri
Download Pdf Manuals
Related Search
Related Contents
TEK WFM 90D,91D User 建築材料実験棟 環境劣化促進装置(14)保守点検業務 Netchef-- Umidificatori a resistenze elettriche LR e LRP Manuale d Electric Wet Pot Bain Marie Manual de instrucciones Helena Isabel Braga Margaride 2º Ciclo de Estudos em Tradução e Jet IO 6550 Manual v1.6 Home Decorators Collection 1305500960 Instructions / Assembly Copyright © All rights reserved.