Home
INSTALLATION & MAINTENANCE MANUAL FOR PV
Contents
1. ES SS 93 1 SS SSS Se SEE Ges mew 00 00 01 um 70x Tum Hmm PER x eee 3 e See we LS AN DU LIVING BY THE SL AN 1 SHS ANTARI WF SOLAR cem Preface This manual offers the general installation and maintenance information of the Photovoltaic Modules hereinafter referred to as the Modules of ANTARIS SOLAR GmbH hereinafter referred to as ANTARIS SOLAR Before installation handling or application of maintenance ensure yourself read and understand this manual and use the Photovoltaic Modules correctly amp safely If you have any questions please feel free to contact the sales manager of ANTARIS SOLAR or our Customer Service General use 1 The operators shall foresee the injury risk during the processes of installation debugging and maintenance of the Modules Therefore these processes shall be accomplished by the professionals with appropriate qualifications 2 Do not dismantle the Modules or tear up any labels 3 Do not touch the exposed cables or connectors 4 After open the packing an opaque cloth or other materials shall be used to cover the frontage of the Modules for the reason that monolithic module may produce potentially fatal current or voltage in the direct sunlight 5 System designers and installers shall design a reasonable bracket Fix the module on the bracket according to the recommended method Please refer the 9th point of the Installation part 6 The ins
2. ct L 8 lt e lt L4 a 6 cm 2400 Pa Drawing 4 a fixing on the long side for the other module series L 8 lt e lt L4 a 6 cm 5400 Pa Drawing 4 a fixing on the long side for the other module series w 8 lt e lt W 4 a gt 6 cm 2400 Pa Drawing 4 b fixing on the Short side for the other module series MANUAL 1 5 LIVING BY THE AN e SN SSSANTARBRIS qE SOLAR cer l i E Es cul o 8 T z jJ pP va w 8 lt e lt W 4 a gt 8 cm 5400 Pa Drawing 4 b fixing on the long side Y EN for the other module series m C Inserting System Fx the module with U type groove or flange beam a All available installation method for A series modules 156 72 Drawing 5 Drawing 5 fixing with sideway for A series modules az8cm_ Drawing 5 fixing with sideway for A series modules L 2 St OMS Le MANUAL I 6 LIVING BY THE B ANTARI 3 OLAR Germ a For other series module fix the module with the long side or short side according to the bracket designation and mechanical load requirement Drawing 6 2400 Pa Drawing 6 fixing with sideway for the other module series 5400 Pa Drawing B fixing with sideway for n M SM L rp ac E nn H M n eT the other module series 5400 Pa Dra
3. dry way Forbidden to clean modules before cooling down MANUAL I 9 LIVING AN faa ANTAR WF SOLAR Gel Annual inspection Check if nuts bolts of mounting structure are secure and not loose Tighten the loose component again if required Check the water resistance of the connecting cables grounding cables and connectors and the performance of the ground resistance Check all electrical and mechanical connections from freedom of corrosion Check the ground resistance of metal parts such as the module frames and the mounting structures Disclaimer of Liability 1 The use of this manual and installation handling maintenance and use of modules are beyond ANTARIS SOLAR s control and ANTARIS SOLAR does not assume any responsibility for loss damage injury or expense resulting from such installation handling use or maintenance ANTARIS SOLAR assumes no responsibility for any infringement of intellectual property right including without limitation patent copyright and trademark or other rights of third parties that may result from use of modules No license in connection with intellectual property right including without limitation patent copyright and trademark or other rights of ANTARIS SOLAR whether expressly or impliedly is granted to customer because of use of modules All information stated in this manual is based on ANTARIS SOLAR s knowledge and experience but no warranty about such informatio
4. ations 2 Do not use damaged Modules Damaged Modules may cause fire or electric shock both the two results could cause the death of the user or installer 3 Do not disconnect the cable under a load circumstance 4 Under normal conditions a Photovoltaic Module may be able to produce voltage and current higher than in standard test condition Accordingly when determining component rated voltage conductor ampacities fuse current and size of controls connected to the PV output the short circuit current and open circuit voltage value marked on this module shall be multiplied by a factor safety factor of 1 25 5 The Modules shall be installed in the position of the sun exposures fully and to ensure that not to be shaded by trees buildings or something others surrounding such as in the northern hemisphere installed towards the south and in the southern hemisphere installed towards the north 6 Use the bracket structure that could withstand the pressure of high winds or heavy snow according to your practical installation condition The bracket structure must be made of durable corrosion resistant UV resistant materials 7 The installation structure must be designed by registered professional engineers and installation design and procedures shall be consistent with the local relevant provisions 8 You could choose either fixing method mentioned below per the actual condition Screw fixing system Drawing 1 a Fixture fixing system D
5. ll not provide any warranty Maintenance 1 Do not touch the live part of the wire cable and the connector When touching use the safety equipment insulating tool insulating gloves etc 2 When maintaining the Modules use opaque cloth or other materials to cover the frontage of the Modules Exposed in sunlight the Photovoltaic Modules may produce high voltage which is a potential danger 3 Cleaning instruction Periodic cleaning is necessary for solar module which could reduce the loss due to dust and is recommended by ANTARIS SOLAR The cleaning processes should be accomplished by the professionals with appropriate qualifications When cleaning the module surface a Rules shown as below must be followed Only at low irradiance the cleaning process could be applied Only soft cloth or sponge could be used to clean the glass surface Only clean water could be used as the cleaning solvent The discrepancy between water temperature and module temperature should be in the range of 5 C to 10 C e Water pressure should be less than 1000 Pa Necessary electrical protection should be taken b Following notes should be taken into account e No other chemical could be used in cleaning process No aggressive tool or coarse material is permitted Do not trample or strike on modules Incleaning process the modules must not be under a load circumstance Do not touch exposed cables or connectors Forbidden to remove dust in
6. n including modules specifications is made by ANTARIS SOLAR whether expressly or impliedly ANTARIS SOLAR reserves the right to update this manual modules specifications or relevant information without prior notice MANUAL I 10 LIVING BY TH ANTAR j ex ANTARIS SOLAR GmbH amp Co KG Member of y Head office Germany 63735 Aschaffenburg Germany DGS Phone 49 0 6095 950 441 5 Fax 49 0 6095 950 544 Email info antaris solar com Internet www antaris solar com
7. rating 14 The minimum separation between two Modules shall be more than 10 mm when installing on the roof the minimum separation between the Modules and the mounting surface shall be more than 150 mm and when installing on the ground more than 450 mm 15 It had better to use the Modules with same configuration in a series connection system 16 Artificially concentrated sunlight shall not be directed on the module 17 Our modules have passed the salt mist and ammonia test Please refer the test report for detailed information and can be installed in some brutal environment e g sea side 18 The modules should not be installed at the place which is less than 100 meters from the seashore If the distance of the seashore and the project site is 100 1000 meters anti corrosion application should be taken during the installation and grounding processes MANUAL 1 LIVING BY TH Gel Am SSSANTA WF SOLAR Product identification Nameplate describes the product model rated power rated current rated voltage open circuit voltage and short circuit current All above parameters are measured in standard test conditions Other information such as weight size maximum system voltage and maximum fuse current are marked on the nameplate as well Barcode the barcode is in the internal of the Modules which containing the relevant retrospect information of the Modules Please do not remove any label or ANTARIS SOLAR wi
8. rawing 1 b or Inserting System SCREW BOLT MODULE FRAME FLAT GASKET FLAT GASKET SPRING WASHER SCREW NUT MOUNTING STRUCTURE Drawing 1 a Installed by nut and bolt Drawing 1 b Installed by fixture Note The safety factor for component rated voltage conductor ampacities fuse current and size of controls connected to the PV output is subject to the meteorological conditions of project sites MANUAL I 3 LIVING BY TH B ANTAR i SOLAR Ger 9 Installation method and location A Screw fixing fix the modules on the bracket on the bracket at 8 border prefabricated installation holes Drawing 2 if t Standard installing hole ae E iren z E x Drawing 2 Screw fixing B Fixture fixing Fix the module safely and effectively on the brackets with special installation tools a For a Series 156 72 modules Six clamps must be used Drawing 3 p L a L 8 lt e lt L 4 a 2 8 cm Drawing 3 a on long frame EX nt E L 2h w 8 lt e lt w 4 a 8 cm V Drawing 3 h on short frame L 2 MANUAL I 4 LIVING AN EED ANTARI YE SOLAR cermar a For other series module fix the module with the long side Drawing 4 a or short side Drawin 4 b according to the bracket designation and mechanical load requirement E 2 ee ie ee se ae TN
9. tallation debugging and maintenance of the Modules etc must be complied with all the electrical engineer safety regulations 7 In the standard test condition the standard test condition is irradiance of 1000 W m battery tag temperature of 25 C and spectrum of AMI 5 the electrical performance parameters of the Modules such as Isc Voc and Pmax have a 10 deviation with the nominal value 8 Do not trample or strike on the Modules 9 Do not spray the chemical non validated or paints on the modules 10 When operating the change of any module or in case of maintenance please take necessity actions to avoid the possible electrical injuries MANUAL I 2 LIVING BY Ti AN 1 SSSANTAHRI WF SOLAR cerr Transport and Carry 1 Carry the Modules carefully and handle them on respecting of instruction 2 Keep the Modules away from inflammable gas hazardous chemicals or fire source 3 Do not carry wet Modules 4 Itis highly recommended to transport with container and the unfilled space the gap over 20cm shall be filled with inflatable bag As for the non container transport the Modules shall be single laid and wholly cared and some effective measures shall be taken to prevent displacement 5 The surface oxide layer of the border may be scratched by sharp objects do not destroy or scratch the border of the Modules Installation 1 Installers must be qualified engineers and familiar with electrical and its applic
10. wing B fixing with sideway for the other module series Anyway fix eight installation holes simultaneously is recommended according to the Security Considerations In the correct installation method the Modules could maximumly bear snow pressure of 5400 Pa or wind pressure of 2400 Pa 2 MANUAL I 7 LIVING BY THE amp AN e Shs ANTARI qE SOLAR Gel 10 When installing the Modules on the roof ensure there is an appropriate structure and a suitable seal shall be made between the Modules and the bracket to prevent leaking 11 Installing the Modules on the roof may affect the fire rating of the house which requires the construction organization to make more accurate assessment 12 The grounding method shall be consistent with the local standard and regulations The grounding wire shall be the bare copper wire with simple surface treatment and no insulation sleeve Wire cable with cross sectional area of 4 6 mm 10 12 AWG and ground clamp Tyco identification of product 1954381 2 are recommended diagrammatic sketches are as follows Installation Drawing 7 Grounded with Ground clamp 13 When the connecting wire of the Modules can not meet system design requirements a proper commercial cable that could endure long term outdoor use and assorted connector could be used to extend the connecting wire The cross sectional area shall be no less than 4 mm and the connection system shall reach IP65 protection
Download Pdf Manuals
Related Search
Related Contents
Samsung HQ-Z364CBP User Manual Manual - Teledyne LeCroy Black Box LES1203A-11G Remote Starter User Manual nett 316renovateur brillanteur pour flancs de pneus, plastiques Chevrolet S-10 Automobile User Manual 18742_SpyNet_SnakeCam_IS BIL 卓越した映像美が語る、 進化する高画質。 USER MANUAL - Hoover Service カタログダウンロード Copyright © All rights reserved.