Home
Installation Manual - 485 Data Module Type B
Contents
1. Figure 4 Overview of connection area Connect each cable to the 485 data module according to the following procedure 1 Plug one spring cage connector into each of the sockets on the 485 data module 2 If one cable is to be connected attach the terminator Push the levers of the terminals 2 and 7 of one spring cage connector upwards Bend the ends of the terminator downwards and plug the terminator into the open terminals e Push the levers back down 3 Push the levers of the terminals 2 5 and 7 of one spring cage connector upwards Installation Manual A85BRD 10 lA en 12 17 9 Electrical Connection SMA Solar Technology AG 4 Connect the wire to the terminals of the spring clamp terminal and note down the colour of the wires The cables can be allocated to any spring cage connector Signal 485 data modules Insulated wire colour GND 5 m Data 2 ba Data 7 5 Close the spring clamp terminals 6 Press each cable with the cable shield into the shield clamp 7 PAANAN E Electric shock due to live cables If during inverter operation an insulated wire L1 L2 or L3 should become detached from the AC terminal there is the risk that the cables of the RS485 communication become live Touching the cables can caus
2. 20 Technical liceali 21 0 4 5 uei ade boca taint eae UE UO EE eens eee 22 Installation Manual 485BRD 10 IA en 12 3 Table of Contents SMA Solar Technology AG 4 A85BRD 10 lA en 12 Installation Manual SMA Solar Technology AG 1 Information on this Document 1 Information on this Document 1 1 Validity This document is valid for the device type 485BRD 10 485 Data Module Type 1 2 Target Group The tasks described in this document must be performed by qualified persons only Qualified persons must have the following skills Training in how to deal with the dangers and risks associated with installing and using electrical devices and plants Training in the installation and commissioning of electrical devices and plants Knowledge of all applicable standards and directives Knowledge of how an inverter works and is operated Knowledge of and compliance with this document and all the safety precautions 1 3 Additional Information Links to additional information can be found at www SMA Solar com Document title Document type RS485 Cabling Plan Technical description 1 4 Symbols Symbol Explanation DANGER Indicates hazardous situation which if not avoided will result in death or serious injury or serious injury A CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a si
3. Prior to performing any work on the inverter always disconnect the inverter from any voltage sources as described in the corresponding installation manual see inverter installation manual NOTICE Damage of components due to electrostatic discharge Touching electronic components on the module or in the inverter can cause damage to or destroy the module and the inverter through electrostatic discharge Earth yourself before touching any components Avoid any contact with components and plug contacts Installation Manual 485BRD 10 IA en 12 11 5 Electrical Connection 5 2 Mounting Position and Cable Routing Figure 3 Item A B C D 12 p SMA Solar Technology AG Mounting position and cable route in the inverter with the enclosure lid open Designation Mounting position Cable route Optional cable route Socket to plug in the 485 data module A85BRD 10 lA en 12 Installation Manual SMA Solar Technology AG 5 Electrical Connection 5 3 Installing the 485 Data Module in the Inverter 1 Disconnect the inverter from voltage sources on the AC and DC sides and open it see the inverter installation manual 2 Attach all spacers in the inverter Insert the plastic spacers into the holes Screw the metal spacer into the screw connection torque 3 5 Nm 0 3 Nm 3 Insert the module
4. Installation Manual 485 Data Module Type B A85BRD 10 lA en 12 Version 1 2 ENGLISH Legal Provisions SMA Solar Technology AG Legal Provisions The information contained in this document is the property of SMA Solar Technology AG Publishing its content either partially or in full requires the written permission of SMA Solar Technology AG Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission SMA Warranty You can download the current warranty conditions from the Internet at www SMA Solar com Trademarks All trademarks are recognized even if not explicitly identified as such A lack of identification does not mean that a product or symbol is not trademarked The BLUETOOTH word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of these marks by SMA Solar Technology AG is under license Modbus is a registered trademark of Schneider Electric and is licensed by the Modbus Organization Inc QR Code is a registered trademark of DENSO WAVE INCORPORATED Phillips and Pozidriv are registered trademarks of Phillips Screw Company Torx is a registered trademark of Acument Global Technologies Inc SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel 49 561 9522 0 Fax 49 561 9522 100 www SMA de E mail infoGSMA de 2004 to 2014 SMA Solar Technology AG All
5. 04 43 Installation Manual SMA Solar Technology AG India SMA Solar India Pvt Ltd Mumbai Italia SMA Italia S r l Milano K rrpoc BA rre Kibris Bkz EAAdd a Yunanistan Luxemburg Siehe Belgien Luxembourg Voir Belgique Magyarorsz g l sd esko Csehorsz g Nederland zie Belgien Belgi sterreich Siehe Deutschland Per Ver Espa a Polska Patrz esko Czechy Portugal SMA Solar Technology Portugal Unipessoal Lda Lisboa Rom nia Vezi esko Cehia Schweiz Siehe Deutschland Slovensko pozri esko esk republika South Africa SMA Solar Technology South Africa Pty Ltd Centurion Pretoria United SMA Solar UK Ltd Kingdom Milton Keynes E ada SMA Hellas AE AOrnva mei SMA Solar Thailand Co Ltd Herala SMA Technology Korea Co Ltd As 971 2 234 6177 International SMA Service Line Niestetal Other countries Installation Manual SMA Middle East LLC 9 Contact 91 22 61713888 39 02 8934 7299 800 20 89 87 Isento de taxas em Portugal 351 2 12 37 78 60 Internacional 08600 SUNNY 08600 78669 International 44 1908 304899 27 12 643 1785 801 222 9 222 International 30 212 222 9 222 66 2 670 6999 82 2 508 8599 free worldwide 00800 5 SERVICE 800 762 7378423 A85BRD 10 IA en 12 23 SMA Solar Technology
6. cable support sleeve into the cable gland and lead each cable all the way up to the sockets on the 485 data module 5 Screw the swivel nut onto the M25 cable gland 6 Remove the protective cover of the multi function relay from the inside of the inverter The protective cover is no longer required Installation Manual 485BRD 10 IA en 12 15 5 Electrical Connection SMA Solar Technology AG Mounting and Preparing the Supplied Cable Gland on the Inverter 16 Remove the plug from the Ethernet socket Unscrew the Ethernet socket from the enclosure Insert the supplied M25 cable gland in the opening enclosure opening and tighten it from the inside using the counter nut torque 3 5 Nm 0 3 Remove the cable support sleeve with one hole from the M25 cable gland and insert the cables into the supplied cable support sleeve with two holes Press the cable support sleeve into the cable gland and lead each cable all the way up to the sockets on the 485 data module Screw the swivel nut onto the M25 cable gland Remove the protective cover of the multi function relay from the inside of the inverter The protective cover is no longer required 485BRD 10 IA en 12 Installation Manual SMA Solar Technology AG 5 Electrical Connection 5 6 Connecting the Cables to the 485 Data Module
7. in the inverter Position the plug at the bottom of the 485 data module in the socket and lead the spacers through the holes in the 485 data module The 485 data module audibly clicks into place 4 Fasten the 485 data module using the screw M4x10 and a Torx screwdriver T 20 torque 3 5 Nm 0 3 Nm Installation Manual 485BRD 10 IA en 12 13 5 Electrical Connection SMA Solar Technology AG 5 4 Preparing the Cables i Disturbance of data transmission due to AC cables During operation AC cables generate an electromagnetic field which may induce interference in plant communication Do not lay the cables of the RS485 communication together with the AC cable Requirement The cable requirements are complied with see Technical Description RS485 Cabling Plan Diameter of the cable when using the cable support sleeve with one hole at maximum 17 mm O Diameter of the cable when using the cable support sleeve with two holes at maximum 6 5 mm Depending on whether the inverter is located at the end or in the middle of the communication bus prepare one or two cables as described in the following 1 Remove 40 mm of the cable sheath at the end of the cable to be connected to the 485 data module Shorten the cable shield to 15 mm Fold the surplus cable shield back onto the cable sheath 4 Wrap the cable shield with copper foil 5 Strip the insulation on the three wires each by 6 mm Two wires for commu
8. rights reserved 2 A85BRD 10 lA en 12 Installation Manual SMA Solar Technology AG Table of Contents Table of Contents Information on this 5 DUMP UID TE EET 5 122 ORGS mi o bebat IR ISTRIA 5 1 3 Additional Information ecole o our Eb Seed 5 RETRO tet Dcus E ROOT etre 5 Lo 6 77 atea T 6 LO ING MENG d eei eet fa det ce echoed re eee 6 Salely reti 7 2 1 Appropriate Usage irripetibili 7 22 150161 PIECOUNONS 8 Scope of Delivery 9 Product Description Lei 10 Al 95 DS used saas Sot dere iade iet das dis dirae trees 10 42 a LI EM MIA 10 Electrical Connection L titre 11 5 1 Safety during Electrical 11 5 2 Mounting Position and Cable 12 5 3 Installing the 485 Data Module in the 13 5 4 Preparing the dlblesssucsau tht Ue e 14 5 5 Preparing the Cable Gland on the Inverter 15 5 6 Connecting the Cables to the 485 Data Module 17 TrOUDIESNOONNG iore e roS oS PRAE AERA A 19 Decoimmissioningx oe bI SEX RE E aa 20 7 1 Disassembling the 485 Data 20 7 2 Packaging the 485 Data Module for Shipping 20 7 3 Disposing of the 485 Data Module
9. the inverter tap twice on the inverter display or see Sunny Portal or Sunny Explorer Special country specific settings of the inverter if applicable Serial number and version of the 485 data module Type and serial number or version of the communication product e g Sunny Explorer Detailed description of the problem Australia SMA Australia Pty Ltd Sydney Belgien SMA Benelux BVBA SPRL Belgique Mechelen Belgi Brasil Vide Espa a Espanha esko SMA Central amp Eastern Europe S r o Praha Chile Ver Espa a Danmark Se Deutschland Tyskland Deutschland SMA Solar Technology AG Niestetal Espa a SMA Ib rica Tecnolog a Solar S L U Barcelona France SMA France S A S Lyon 22 A85BRD 10 lA en 12 Toll free for Australia 1800 SMA AUS 1800 762 287 61 2 9491 4200 International 32 15 286 730 420 235 010 417 Medium Power Solutions Wechselrichter 49 561 9522 1499 Kommunikation 49 561 9522 2499 SMA Online Service Center www SMA de Service Hybrid Energy Solutions Sunny Island 49 561 9522 399 PV Diesel 49 561 9522 3199 Hybridsysteme Power Plant Solutions 49 561 9522 299 900 14 22 22 Sunny Central llamada gratuita en Espafia 34 902 14 24 24 Medium Power Solutions 33 472 09 04 40 33 472 09 04 41 Hybrid Energy Solutions 33 472 09 04 42 Internacional Onduleurs Communication Sunny Island Power Plant Solutions Sunny Central 33 472 09
10. 0TL 20 STP 7000TL 20 WTP 7000TL 20 STP 8000TL 20 WTP 8000TL 20 STP 9000TL 20 WTP 9000TL 20 STP 10000TL 20 STP 1 2000TL 20 Use this product only in accordance with the information provided in the enclosed documentation and with the locally applicable standards and directives Any other use may result in personal injury or property damage For safety reasons it is not permitted to modify the product or install components that are not explicitly recommended or distributed by SMA Solar Technology AG for this product The enclosed documentation is an integral part of this product Read and observe the documentation Keep the documentation in a convenient place for future reference Installation Manual A85BRD 10 lA en 12 2 Safety SMA Solar Technology AG 2 2 Safety Precautions This section contains safety precautions that must be observed at all times when working on or with the product To prevent personal injury or property damage and to ensure long term operation of the product read this section carefully and follow the safety precautions at all times A WARNING Electric shock due to live voltage High voltages that can cause fatal electric shocks are present in the live components of the inverter Prior to performing any work on the inverter always disconnect the inverter from any voltage sources as described in the corresponding installation manual see inverter installation manual A CAUTION Risk of burns
11. al RS485 cabling plan Expanding rivet Plastic foil for isolating the communication connection from the AC connection A85BRD 10 IA en 12 9 4 Product Description SMA Solar Technology AG 4 Product Description 4 1 485 Data Module The 485 data module enables you to setup cable connected RS485 communication Item Designation A Holes for attaching the data module using the plastic spacers B Sockets to plug in the spring clamp terminals Hole for attaching plastic foil D Shield clamps E Hole for attaching the data module using the metal spacer F Type label 4 2 Type Label The type label clearly identifies the 485 data module The type label is located on the front of the 485 data module i Al D FA 2998693 SER 0000008 Bree SnAgCu c 485BRD 10 861 Figure 2 Layout of the type label example Item Explanation A Number of the production order B Version of the 485 data module C Device type D Serial number You require the information on the type label for customer support from the SMA Service Line The type label must remain permanently attached to the 485 data module 10 485BRD 10 IA en 12 Installation Manual SMA Solar Technology AG 5 Electrical Connection 5 Electrical Connection 5 1 Safety during Electrical Connection DANGER Danger to life due to electric shock High voltages that can cause fatal electric shocks are present in the live components of the inverter
12. due to hot enclosure parts Some parts of the inverter enclosure can get hot during operation e During operation touch the inverter on the enclosure lid and the protective cover only NOTICE Damage to the 485 data module or the inverter due to electrostatic discharge Touching electronic components on the 485 data module or in the inverter can cause damage to or destroy the 485 data module and the inverter through electrostatic discharge Earth yourself before touching any components Avoid any contact with components and plug contacts 8 48 5BRD 10 IA en 12 Installation Manual SMA Solar Technology AG 3 Scope of Delivery 3 Scopeof Delivery Check the scope of delivery for completeness and any externally visible damage Contact your specialist dealer if the delivery is incomplete or damaged If the 485 data module has already been installed in the inverter at the factory only those parts necessary for electrical connection are included in the scope of delivery Figure 1 Item A m U 0ny y uvo z r Qo T Components included in the scope of delivery Number N Installation Manual Designation 485 data module M4x10 screw Plastic spacer Metal spacer M25 cable gland with sealing plug cable support sleeve with one hole and M25 counter nut Cable support sleeve with two holes for M25 cable gland Copper foil Spring cage connector Terminator Installation manu
13. e fatal electric shock Attach the supplied plastic foil to the module using the supplied expanding rivet This isolates the AC connection area in the inverter from other terminals 8 Tighten the swivel nut of the cable gland Close and commission the inverter see inverter installation manual O Connect the cable end to the RS485 bus for information on the terminal assignment and wiring in the system see the Technical Description RS485 Cabling Plan A85BRD 10 IA en 12 Installation Manual SMA Solar Technology AG 6 Troubleshooting Problem The emergency channel list Emergncy or EmgncyXX is displayed in the communication product e g Sunny WebBox Sunny Explorer The inverter is displayed with the device class Other in Sunny Portal Installation Manual 6 Troubleshooting Cause and corrective measures The 485 data module has been installed in an inverter without first disconnecting the inverter on the AC and DC sides This prevents the inverter from detecting the new 485 Data Module Corrective measures e Prior to performing any work on the inverter disconnect the inverter from any voltage sources on the AC and DC sides see inverter installation manual Several SMA communication products query data simultaneously from the devices via Bluetooth e g Sunny Explorer Sunny Beam with Bluetooth and RS485 communication e g Sunny WebBox This can cause data congest
14. ion if a lot of data is transmitted simultaneously If this state lasts for more than five minutes the inverter carries out a reset of the 485 data module Due to the data congestion the inverter cannot detect the 485 data module after the reset Corrective measures Wait until the inverter restarts the next morning then the inverter will detect the 485 data module or Disconnect the inverter from voltage sources on the AC and DC sides and recommission it see the inverter installation manual A85BRD 10 IA en 12 19 7 Decommissioning SMA Solar Technology AG 7 Decommissioning 7 1 Disassembling the 485 Data Module 1 Disconnect the inverter from voltage sources on the AC and DC sides and open it see the inverter installation manual Open the spring clamp terminals of the plug at the 485 data module Remove the wires from the plug Slightly loosen the swivel nut of the cable gland and remove the cable support sleeve Remove each cable from the inverter and from the cable support sleeve Si ge co qe Unscrew the screw M4x10 to which the 485 data module is attached to the inverter using a Torx screwdriver T 20 7 Remove the 485 data module from the inverter The spacers remain in the inverter 8 Insert the sealing plug into the cable gland This ensures that the inverter complies with its degree of protection 9 Tighten the swivel nut of the cable gland 10 Close and commiss
15. ion the inverter see inverter installation manual 7 2 Packaging the 485 Data Module for Shipping e Pack the 485 data module Use the original packaging or packaging that is suitable for the weight and size of the 485 data module 7 3 Disposing of the 485 Data Module e Dispose of the 485 data module in accordance with the regulations for the disposal of electronic waste applicable at the installation site 20 485BRD 10 IA en 12 Installation Manual SMA Solar Technology AG 8 Technical Data Mechanical Data Dimensions width x height x depth Weight Communication Communication interface Maximum cable length Connections Type of plug Number of RS485 terminals Ambient Conditions during Operation Ambient temperature Relative humidity non condensing Maximum height above sea level MSL Ambient Conditions for Storage Transport Ambient temperature Relative humidity non condensing Maximum height above MSL Installation Manual 8 Technical Data 127 mm x 77 mm x 39 mm 47 g RS485 1 200 m 4 spring clamp terminal 2 25 Ctio 85 C 5 to 95 3 000 m 40 C to 85 C 5 to 95 3 000 m A85BRD 10 lA en 12 21 9 Contact 9 Contact SMA Solar Technology AG If you have technical problems concerning our products please contact the SMA Service Line We require the following information in order to provide you with the necessary assistance Serial number and firmware version of
16. nication must be a twisted pair 6 Shorten all other wires flush with the cable sheath 14 485BRD 10 IA en 12 Installation Manual SMA Solar Technology AG 5 Electrical Connection 5 5 Preparing the Cable Gland on the Inverter In order to prepare the cable gland on the inverter you have to know whether one or two cables are to be connected to the 485 data module and whether the multi function relay in the inverter is to be used immediately or at a later time If you wish to connect one or two cables to the 485 data module and do not want to use the multi function relay in the inverter neither immediately nor at a later time prepare the M25 cable gland on the inverter for one or two cables If you wish to connect two cables to the 485 data module and the multi function relay in the inverter is used immediately or at a later time you must remove the Ethernet socket from the inverter and mount another M25 cable gland on the inverter Preparing the Cable Gland on the Inverter for One or Two Cables 1 Unscrew the swivel nut from the M25 cable gland and push out the sealing plug 2 If one cable is to be connected remove the cable support sleeve with one hole from the M25 cable gland and insert the cable into the one hole cable support sleeve 3 If two cables are to be connected remove the cable support sleeve with one hole from the M25 cable gland and insert the cables into the supplied two hole cable support sleeve 4 Press the
17. tuation which if not avoided could result in property damage Information that is important for a specific topic or goal but is not safety relevant Indicates an essential requirement for achieving a specific goal Desired result x A problem that might occur Installation Manual 485BRD 10 IA en 12 5 1 Information on this Document 1 5 Typography Typography Explanation bold Button Key 1 6 Nomenclature Display texts Elements of a user interface Terminals Elements to be selected Elements to be entered Connects several elements to be selected Button or key to be selected or pressed SMA Solar Technology AG Example The value can be read from the Energy field Select Settings Enter the value 10 in the Minutes field Select Settings gt Date Select Next In this document the 485 Data Module Type B is referred to as 485 data module 6 A85BRD 10 lA en 12 Installation Manual SMA Solar Technology AG 2 Safety 2 Safety 2 1 Appropriate Usage The 485 data module enables you to setup cable connected RS485 communication The 485 data module can be retrofitted or installed in the inverter at the factory if specified in the order The inverter still complies with the standard after the product has been installed The 485 data module is suitable for installation in the following SMA inverters Sunny Tripower Windy Tripower STP 5000TL 20 WTP SOOOTL 20 STP 6000TL 20 WTP 600
Download Pdf Manuals
Related Search
Related Contents
Samsung BX2231 Lietotāja rokasgrāmata Harbor Freight Tools 9 Hot Laminator Product manual NM-280 NM-245 - Junkkari Palvelut Samsung BD-J5500 Kullanıcı Klavuzu ZENworks Reporting 5-Systemreferenz EZ9260-EVB Development Board Hardware Manual Pundit PL-200 Istruzioni d`uso Copyright © All rights reserved.