Home

"Installation Manual - Replacement of SMA Devices in Systems with

image

Contents

1. Select Next M A summary is displayed Select Finish Geraeteaustausch lA en 20 Installation Manual SMA Solar Technology AG 8 Cluster Controller System 8 Cluster Controller System 8 1 Procedure when Replacing Different Devices Procedure See 1 Replacing the Inverter with Speedwire in Cluster Controller Section 8 2 page 15 2 Replacing the Cluster Controller Section 8 3 page 17 3 Replacing the Battery Pack Smart Energy Section 12 3 page 28 8 2 Replacing the Inverter with Speedwire in Cluster Controller Procedure e Replacing an Inverter in Cluster Controller e Replacing an Inverter in the Sunny Portal System Replacing an Inverter in Cluster Controller 1 Read the serial number of the inverter to be replaced off the type label and write it down 2 Determine the energy yield of the inverter to be replaced Log into the user interface of the Cluster Controller Select the inverter to be replaced in the system tree Select Overview and read off and write down the value in the Total yield row 3 If you are using Sunny Portal you must send all data saved to the inverter and to the Cluster Controller to Sunny Portal prior to replacing the inverter Select the Cluster Controller in the system tree Select Settings gt Sunny Portal gt Basic settings gt Edit Select Every 15 minutes in the drop down list Upload frequency Select Save The saving process may take a few minutes
2. Installation Manual Replacement of SMA Devices in Systems with SMA Communication Products Geraeteaustausch lA en 20 Version 2 0 ENGLISH Legal Provisions SMA Solar Technology AG Legal Provisions The information contained in this document is the property of SMA Solar Technology AG Publishing its content either partially or in full requires the written permission of SMA Solar Technology AG Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission SMA Warranty You can download the current warranty conditions from the Internet at www SMA Solar com Trademarks All trademarks are recognized even if not explicitly identified as such A lack of identification does not mean that a product or symbol is not trademarked The BLUETOOTH word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of these marks by SMA Solar Technology AG is under license Modbus is a registered trademark of Schneider Electric and is licensed by the Modbus Organization Inc GR Code is a registered trademark of DENSO WAVE INCORPORATED Phillips 9 and Pozidriv are registered trademarks of Phillips Screw Company Torx is a registered trademark of Acument Global Technologies Inc SMA Solar Technology AG Sonnenallee 1 34266 Niestetal Germany Tel 49 561 9522 0 Fax 49 561 9522 100 www SMA de E mail info SMA d
3. Niestetal Wechselrichter 49 561 9522 1499 49 561 9522 2499 www SMA de Service Hybrid Energy Solutions Sunny Island PV Diesel Hybridsysteme 49 561 9522 399 49 561 9522 3199 Power Plant Solutions Sunny Central 49 561 9522 299 Espa a SMA Ib rica Tecnologia Solar S L U Llamada gratuita en Espa a 900 14 22 22 Barcelona Internacional 34 902 14 24 24 France SMA France S A S Medium Power Solutions Lyon Onduleurs 33 472 09 04 40 Communication 33 472 09 04 41 Hybrid Energy Solutions Sunny Island 33 472 09 04 42 Power Plant Solutions Sunny Central 33 472 09 04 43 India SMA Solar India Pvt Ltd 91 2261713888 Mumbai Italia SMA Italia S r l 39 02 8934 7299 Milano K rrpoc Bherre EAAd6a K br s Bkz EMa a Yunanistan Luxemburg Siehe Belgien Luxembourg Voir Belgien Belgique Magyarorsz g l sd esko Csehorsz g 30 Geraeteaustausch lA en 20 Installation Manual SMA Solar Technology AG 13 Contact Nederland zie Belgien Belgi sterreich Siehe Deutschland Per Ver Espa a Polska Patrz Cesko Czechy Portugal SMA Solar Technology Portugal Gratuito em Portugal 800 20 89 87 Unipessoal Lda Internacional 3512 12377860 Lisboa Rom nia Vezi Cesko Cehia Schweiz Siehe Deutschland Slovensko pozri Cesko Cesk republika South Africa SMA Solar Technology 08600 SUNNY South Africa Piy Ltd 08600
4. Only displayed ifthere is an SMA Energy Meter in the PV system e Select Save Installation Manual Geraeteaustausch lA en 20 9 6 Sunny Home Manager System SMA Solar Technology AG 6 3 Replacing an Inverter in the Sunny Home Manager System The communication between the Sunny Home Manager and an SMA inverter is possible either via BLUETOOTH or via Speedwire Depending on the type of communication used between the Sunny Home Manager and the SMA inverter read the relevant section Requirement LI The data retrieval interval must be set to automatic in the Sunny Home Manager see the Sunny Home Manager user manual The data retrieval interval of the Sunny Home Manager is factory set to automatic 6 3 1 Replacing an Inverter with Speedwire 1 Decommission the inverter to be replaced see the inverter manual 2 If you retrofit the new inverter with Speedwire Webconnect communication install the Speedwire Webconnect interface in the inverter and commission see the Speedwire Webconnect interface manual 3 If BLUETOOTH communication is integrated in the new inverter turn the rotary switch on the inverter for the NetID with a screwdriver blade width 2 5 mm to O see the inverter manual This deactivates the BLUETOOTH function 4 Commission the new inverter see inverter manual 5 Add the new inverter to the Sunny Portal system in Sunny Portal e Log into Sunny Portal and call up the Sunny Portal system e Select Configuratio
5. page 25 3 Replacing the Battery Pack Smart Energy Section 12 3 page 28 11 1 2 Replacing the SMA Energy Meter See Section 12 2 page 27 11 l 2 1 3 Replacing an Inverter with Speedwire in Sunny Explorer Read the serial number of the inverter to be replaced off the type label and write it down Determine the energy yield of the inverter to be replaced e Log into Sunny Explorer at the Speedwire system Select the inverter to be replaced in the system tree Select Overview and read off and write down the value in the Total yield row 3 Decommission the inverter to be replaced see the inverter manual If you retrofit the new inverter with Speedwire Webconnect communication install the Speedwire Webconnect interface in the inverter and commission see the Speedwire Webconnect interface manual If BLUETOOTH communication is integrated in the new inverter turn the rotary switch on the inverter for the NetID with a screwdriver blade width 2 5 mm to O see the inverter manual This deactivates the BLUETOOTH function 6 Commission the new inverter see inverter manual 9 10 Log into Sunny Explorer at the Speedwire system Sunny Explorer automatically detects the new inverter The new inverter is displayed with a padlock symbol in the system tree Set the system passwords of the existing Speedwire system for the new inverter e Set up a new Speedwire system in Sunny Explorer and log in as Ins
6. 0 D Delete the Sunny WebBox buffer Non deleted data in the buffer can lead to serious and irreversible distortion of the yield data in Sunny Portal By deleting the buffer you will ensure that no data which has been temporarily stored in the buffer is sent to Sunny Portal 10 Select WebBox gt Info and select Delete device descriptions This will ensure that there is no distortion of instantaneous values and parameters on the Sunny WebBox user interface W The device descriptions in the Sunny WebBox will be deleted and then detected automatically when the Sunny WebBox is restarted Replacing an Inverter in the Sunny Portal System Carry out the following steps only if you are using Sunny Portal Procedure 1 Read off the serial number of the new inverter off the type label and write it down This way you can identify the new inverter in Sunny Portal for replacement 2 Activate the data transmission between Sunny WebBox and Sunny Portal again Select WebBox gt Settings gt Data trans in the Sunny WebBox user interface In the Portal settings area activate the option Yes in the field Use Sunny Portal 3 Select Save The saving process may take a few minutes 4 Replace the new inverter in the Sunny Portal system e Log into Sunny Portal and call up the Sunny Portal system e Sunny Portal recognizes the new inverter and opens the configuration wizard automatically To open the configuration wizard manually select Name of
7. a A ea aa 12 System with Micro Inverters and Sunny Multtegote ceci 13 7 1 ProcedurewhenReplacingDifferentDevices 13 7 2 Replacing a Micro Inverter in Sunny Multigate 522 4 10410141441 il lada abdi eki p 13 7 3 Replacing the Sunny Multigate in Sunny Portal ocio not ei sleek Bra ate EE 14 Cluster Controller Systema o rie ARA 15 8 1 ProcedurewhenReplacingDifferentDevices 15 8 2 ReplacingthelnverterwithSpeedwireinClusterController 15 8 3 Replacing the Cluster Controller Lodi lorelai profe te 17 8 4 Replacing the Battery Pack Smart Energy REN geed et Ee iS elli bii 18 System withSunnyWebBoxwithBLUETOOTH 0000000 19 9 1 Procedure when Replacing Different Devices cias dci dE dk elle 19 9 2 Replacing an Inverter with BLUETOOTH in the Sunny WebBox with BLUETOOTH 19 9 3 ReplacingtheSunnyyWebBoxwithBLUETOOTH net nee eens 21 System withSunnyWebBox 000000 22 10 1 ReplacementProcedurewhenReplacingDifferentDevices 22 10 2 Replacing an Inverter with RS485 in the Sunny WebBox 22 10 3 EE 23 Installation Manual Geraeteaustausch lA en 20 3 Table of Contents SMA Solar Technology AG 11 System with Sunny Explorer 25 11 1 Speedwire System with Su
8. an SMA Energy Meter and there is more than one SMA Energy Meter in your system write down the serial number of the new SMA Energy Meter indicated on the type label This way you can identify the SMA Energy Meter in Sunny Portal later on during configuration 2 Remove the energy meter to be replaced see energy meter manual Mount the new energy meter and commission it see energy meter manual 4 Configure the energy meter in Sunny Portal e Log into Sunny Portal and call up the Sunny Portal system e Select Configuration gt Device Overview e n the Sunny Home Manager row select in the Properties column e Select Edit and the type of the new energy meter in the Meter Configuration area in the drop down lists Connected energy meter type Drop down list Energy meter with DO Interface e Select DO Bidirectional meter with DO interface e Select DO Activate the field Bidirectional meter Supply and feed in M The area Meter input 2 is not available Energy meter with SO Interface Select SO In the field SO pulses kWh enter the pulse rate of the energy meter see energy meter manual SMA Energy Meter Select SMA Energy Meter xxx The placeholder for the SMA Energy Meter serial number is xxx If there is more than one SMA Energy Meter in the system identify and select the requested SMA Energy Meter by its serial number Activate the checkbox Bidirectional meter Supply and feed in
9. devices in the system 13 Set the the noted energy yield of the inverter to be replaced in the new inverter Select the new inverter on the user interface of the Cluster Controller in the system tree Select Settings gt AC side gt Edit e Enter the noted energy yield of the inverter to be replaced in the field Set total yield and then select Save The saving process may take a few minutes Replacing an Inverter in the Sunny Portal System Carry out the following steps only if you are using Sunny Portal Procedure 1 Read off the serial number of the new inverter off the type label and write it down This way you can identify the inverter for replacement in Sunny Portal 2 Send the data of the new inverter saved to the Cluster Controller memory to Sunny Portal e Select the Cluster Controller in the system tree e Select Settings gt Sunny Portal gt Basic settings gt Edit Select Every 15 minutes in the drop down list Upload frequency e Select Save e Select Logout and wait 20 minutes This will ensure that that the data transmission between Cluster Controller and Sunny Portal has been terminated e Check whether the upload to Sunny Portal was successful on the user interface of the Cluster Controller Select the Cluster Controller in the system tree and select Settings gt Sunny Portal gt Last successful upload 3 Replace the new inverter in the Sunny Portal system e Log into Sunny Portal and call u
10. system in Sunny Portal Inverter with activated Webconnect function See Section 5 page 8 Required for replacement Computer with Sunny Explorer and connection to the router in the system System password for user role Installer Login data of the Sunny Portal system with user role Installer or Administrator Sunny Home Manager Section 6 page 9 System password for user role Installer Login data of the Sunny Portal system and user role Installer or Administrator Sunny Multigate System with micro inverters Section 7 page 13 Computer with Sunny Explorer and connection to the router in the system System password for user role Installer Login data of the Sunny Portal system with user role Installer or Administrator Cluster Controller Section 8 page 15 Access to the Cluster Controller System password for user role Installer Login data of the Sunny Portal system with user role Installer or Administrator Sunny WebBox with BLUETOOTH Section 9 page 19 Access to the Sunny WebBox with BLUETOOTH System password for user role Installer Login data of the Sunny Portal system with user role Installer or Administrator Sunny WebBox Section 10 page 22 Access to the Sunny WebBox System password for user role Installer Login data of the Sunny Portal system with user role Installer or Administrator Sunny Explorer Installation Manual Section 11 page 25 Computer with Sun
11. upload row M The value Sunny Portal buffer load is 0 4 Decommission the inverter to be replaced see the inverter manual 5 If you are retrofitting your new inverter with RS485 communication install the RS485 interface in the inverter and commission it see RS485 interface manual 6 Commission the new inverter see inverter manual 7 Detect the new inverter with the Sunny WebBox Log into the user interface of the Sunny WebBox Select PV system gt Detection e Enter the number of newly connected inverters in the field Total number of devices to be detected and select Start detection e When the detection of the connected inverters is completed select OK 8 Transfer the noted energy yield of the inverter to be replaced to the new inverter Be aware that the parameter displayed is dependent on the inverter device type n the Sunny WebBox user interface select the inverter in the system tree e Select the tab Parameters e Call up the parameter for the energy yield of the new inverter In the list of parameters search for the parameter with the kWh unit in the Unit column In the column Value enter the noted energy yield of the inverter to be replaced in the field Select Save 22 Geraeteaustausch lA en 20 Installation Manual SMA Solar Technology AG 10 System with Sunny WebBox 9 Select WebBox gt Info and select Delete in the Sunny Portal buffer load row M The value Sunny Portal buffer load is
12. 78669 Centurion Pretoria International 27 12 643 1785 United Kingdom SMA Solar UK Ltd 44 1908 304899 Milton Keynes E ada SMA Hellas AE 801 222 9 222 Ava nternational 30 212 222 9 222 benrapua Bure EMa a l opuna le SMA Solar Thailand Co lid 66 2 670 6999 ERC Herala SMA Technology Korea Co Ltd 82 2 508 8599 ME 971 2 234 6177 SMA Middle East LLC cl yayi ib si Ss Sall dy pall Other countries International SMA Service Line Toll free worldwide 00800 SMA SERVICE Niestetal 800 762 7378423 Installation Manual Geraeteaustausch lA en 20 31 SMA Solar Technology www SMA Solar com
13. ER Danger to life due to high voltages on the Battery Pack Lethal voltage is present at the pin connector for the power cable Reaching into the pin connector for the power cable can result in lethal electric shock e Prior to performing any work on the inverter and on the Battery Pack always disconnect the inverter from all voltage sources see the inverter operating manual at www SMA Solar com The Battery Pack may only be mounted and installed by qualified persons with appropriate qualifications for information on the qualifications of the qualified persons see the operating manual at www SMA Solar com Do not open the Battery Pack and leave the protective caps on the pin connectors of the new Battery Pack until the inverter cables are connected to the new Battery Pack Procedure on Receipt of a New Battery Pack e Disassembling the Defective Battery Pack e Mounting the New Battery Pack and Connecting It to the Inverter e Packing the Defective Battery Pack and Organizing Its Return Di l sassembling the Defective Battery Pack Open the packaging of the new Battery Pack and remove the delivery documents and the return note Be careful when handling the packaging as you will need it later for packing the defective Battery Pack 2 Compare the serial number on the return note with the serial number of the defective Battery Pack The serial numbers must be identical 3 Keep the delivery documents of the new Batte
14. Select Logout and wait 20 minutes This will ensure that that the data transmission between the Cluster Controller and Sunny Portal has been terminated Log into the user interface of the Cluster Controller and check whether the upload to Sunny Portal was successful Select the Cluster Controller in the system tree and select Settings gt Sunny Portal gt Last successful upload 4 Decommission the inverter to be replaced see the inverter manual 5 If you retrofit the new inverter with Speedwire Webconnect communication install the Speedwire Webconnect interface in the inverter and commission see the Speedwire Webconnect interface manual 6 If BLUETOOTH communication is integrated in the new inverter turn the rotary switch on the inverter for the NetID with a screwdriver blade width 2 5 mm to O see the inverter manual This deactivates the BLUETOOTH function 7 Commission the new inverter see inverter manual 8 Log into the user interface of the Cluster Controller M The new inverter is displayed with a padlock symbol in the system tree 9 Adapt the system password to the device password of the new inverter so that you can access the new inverter Select the Cluster Controller in the system tree Select Settings gt User rights gt Access control gt Edit Enter the password of the user group Installer standard password 1111 set up in the new inverter in the fields Set installer password and Confirm the passwor
15. TOOTH Section 9 3 page 21 9 2 Replacing an Inverter with BLUETOOTH in the Sunny WebBox with BLUETOOTH Procedure e Replacing an Inverter in the Sunny WebBox with BLUETOOTH e Replacing an Inverter in the Sunny Portal System Replacing an Inverter in the Sunny WebBox with BLUETOOTH 1 Read the serial number of the inverter to be replaced off the type label and write it down 2 Determine the energy yield of the inverter to be replaced e Log into the user interface of the Sunny WebBox with BLUETOOTH e Select the inverter to be replaced in the system tree Select Overview and read off and write down the value in the row Total 3 If you are using Sunny Portal you must transfer all data saved to the inverter and saved to the Sunny WebBox with BLUETOOTH to Sunny Portal before replacing the inverter e Inthe Sunny WebBox with BLUETOOTH user interface select the Sunny WebBox with BLUETOOTH in the system tree Select Settings gt Sunny Portal gt Edit In the Basic settings area select Every 15 minutes in the drop down list Upload frequency e Select Save e Select Logout in the toolbar and wait 20 minutes This will ensure that the data transmission between Sunny WebBox with BLUETOOTH and Sunny Portal has been terminated 4 Decommission the inverter to be replaced see the inverter manual 5 If you retrofit the new inverter with BLUETOOTH communication install the BLUETOOTH interface in the inverter and commission se
16. UETOOTH and opens the configuration wizard automatically To open the configuration wizard manually select Name of your system gt System monitoring gt Set up device now Select in the row of the new Sunny WebBox with BLUETOOTH and follow the configuration wizard instructions Installation Manual Geraeteaustausch lA en 20 21 10 System with Sunny WebBox SMA Solar Technology AG 10 System with Sunny WebBox 10 1 Replacement Procedure when Replacing Different Devices Procedure See 1 Replacing an Inverter with RS485 in the Sunny WebBox Section 10 2 page 22 2 Replacing the Sunny WebBox Section 10 3 page 23 10 2 Replacing an Inverter with RS485 in the Sunny WebBox Procedure e Replacing an Inverter in the Sunny WebBox e Replacing an Inverter in the Sunny Portal System Replacing an Inverter in the Sunny WebBox 1 Read the serial number of the inverter to be replaced off the type label and write it down 2 Determine the energy yield of the inverter to be replaced e Log into the user interface of the Sunny WebBox e Select PV System gt Devices and select the inverter to be replaced Select the tab Overview and read off and write down the value in the Energy total row 3 If you are using Sunny Portal you must transfer all data saved to the inverter and to the Sunny WebBox to Sunny Portal before replacing the inverter Select WebBox gt Info in the Sunny WebBox user interface e Select Upload in the Last portal
17. UETOOTH in the system tree Select Settings gt Device gt Edit Inthe System area select Execute in the drop down list Initiate device restart Select Save M The Sunny WebBox with BLUETOOTH is restarted The restart was successful if the LED SYSTEM and the LED POWER are glowing green again The start up procedure can take up to 90 seconds 10 Log into the user interface of the Sunny WebBox with BLUETOOTH M The password of the new inverter is adapted to the PV system password The new inverter is displayed without a padlock symbol in the system tree 11 Set the the noted energy yield of the inverter to be replaced in the new inverter n the Sunny WebBox with BLUETOOTH user interface select the new inverter in the system tree Select Settings gt AC side gt Edit e Enter the noted energy yield of the inverter to be replaced in the field Set total yield in the Measured values area Select Save The saving process may take a few minutes Replacing an Inverter in the Sunny Portal System Carry out the following steps only if you are using Sunny Portal Procedure 1 Readoffthe serial number of the new inverter off the type label and write it down This way you can identify the new inverter in Sunny Portal for replacement 2 Replace the new inverter in the Sunny Portal system e Log into Sunny Portal and call up the Sunny Portal system e Sunny Portal recognizes the new inverter and opens the configur
18. ation wizard automatically To open the configuration wizard manually select System monitoring gt Set up device now e Select 2 in the row of the new inverter and follow the configuration wizard instructions 20 Geraeteaustausch lA en 20 Installation Manual SMA Solar Technology AG 9 System with Sunny WebBox with BLUETOOTH 9 3 Replacing the Sunny WebBox with BLUETOOTH Requirement LI The software Sunny WebBox Assistant must be installed on the computer available free of charge at www SMA Solar com Procedure 1 If you are using Sunny Portal and if the Sunny WebBox with BLUETOOTH to be replaced still allows it transfer the data saved to the Sunny WebBox with BLUETOOTH to Sunny Portal before replacing the Sunny WebBox with BLUETOOTH e Log into the user interface of the Sunny WebBox with BLUETOOTH e Select the Sunny WebBox with BLUETOOTH in the system tree Select Settings gt Sunny Portal gt Edit In the Basic settings area select Every 15 minutes in the drop down list Upload frequency Select Save The saving process may take a few minutes Select Logout in the toolbar and wait 20 minutes This will ensure that the data transmission between Sunny WebBox with BLUETOOTH and Sunny Portal has been terminated 2 Decommission the Sunny WebBox with BLUETOOTH to be replaced see the Sunny WebBox with BLUETOOTH installation manual 3 Start the Sunny WebBox Assistant on the computer and connect the Sunny WebBox
19. d Enter the password of the user group User standard password 0000 set up in the new inverter in the fields Set user password and Confirm the password Select Save M The Cluster Controller changes the system passwords for all approved devices in the system Installation Manual Geraeteaustausch lA en 20 15 8 Cluster Controller System SMA Solar Technology AG 10 Restart the Cluster Controller via the user interface e Select the Cluster Controller in the system tree Select Settings gt Device gt System n the field Initiate device restart select Submit M The Cluster Controller is restarted The start up procedure can take up to two minutes 11 Check whether the new inverter is displayed without a padlock symbol in the Cluster Controller e Log into the user interface of the Cluster Controller MI The new inverter is displayed without a padlock symbol in the system tree 12 Set the previous system password in all devices Select the Cluster Controller on the user interface of the Cluster Controller in the system tree Select Settings gt User rights gt Access control gt Edit e Enter the previous system password of the user group User in the fields Set user password and Confirm the password e Enter the previous system password of the user group Installer in the fields Set installer password and Confirm the password e Select Save MI The Cluster Controller changes the system passwords for all approved
20. e 2004 to 2014 SMA Solar Technology AG All rights reserved 2 Geraeteaustausch lA en 20 Installation Manual SMA Solar Technology AG Table of Contents Table of Contents 1 a BEN 10 Information on this Document 00 nac e REN 5 TAL AA A ON 5 142 sfargetGioup A A E ad AA dee Ee EE 5 US Symbols 0 ES E bilie iii 5 TA Typographies ee dE O Re yy TI Sp lay meri 5 Safe AS AE A A E 6 General Information aspartame 6 Which SectionAppliestomySystem 00 7 WebconnectSysteminSunnyPortal 0000000 8 5 1 ProcedurewhenReplacingDifferentDevices 8 5 2 ReplacingtiheSMAEnergyMeterbyMeansofSunnyExplorer 8 5 3 Replacing Inverters with WebconnectCommunicationinSunnyPortal 8 5 4 Replacing the Battery Pack Smart Energy delirar A de 8 Sunny Home Manager System coco 9 6 1 ProcedurewhenReplacingDifferentDevices 9 6 2 Replacing the SMA Energy Meter or Other Energy Meters in a Sunny Home Manager System 9 6 3 ReplacinganlnverterintheSunnyyHomeManagerSystem 10 6 3 1 ReplacinganlnverterwithSpeedwire 10 6 3 2 Replacing an Inverter with BLUETOOTH ene ee 11 6 4 Replacing the Battery Pack MORENA AAA RA 11 6 5 Replacing the Sunny Home Manager ii
21. e Packing the Defective Battery Pack and Organizing lts Return A DANGER Danger to life due to incorrect packaging and transport The Battery Pack is considered to be dangerous goods Special regulations must be complied with AY regarding packaging and transport S e Packaging and transport of the Battery Pack may only be carried out by persons who have been trained in accordance with Section 1 3 ADR and whose training has been documented Place the supplied foil bag in the packaging in which the new Battery Pack was delivered The open side of the foil bag must face upwards Place the defective Battery Pack in the foil bag Place the moisture absorber next to the defective Battery Pack in the foil bag Close the foil bag Seal the packaging with suitable adhesive tape O O BEM Organize the return of the package Contact the SMA Service Line Installation Manual Geraeteaustausch lA en 20 29 Kommunikation SMA Online Service Center 13 Contact SMA Solar Technology AG 13 Contact Australia SMA Australia Pty Ltd Toll free for Australia 1800 SMA AUS Sen 1800 762 287 International 61 2 9491 4200 Belgien SMA Benelux BVBA SPRL 32 15 286 730 Belgigve Mechelen Belgi Brasil Vide Espa a Espanha Cesko SMA Central amp Eastern Europe s r o 420 235010417 Praha Chile Ver Espa a Danmark Se Deutschland Tyskland Deutschland SMA Solar Technology AG Medium Power Solutions
22. e device configuration bak M The file selection window opens Select the desired configuration file and select Open M The file name of the selected configuration file is displayed in the Restore device configuration bak e Select Submit Wl The configuration file is uploaded and the device configuration is restored The Cluster Controller restarts Installation Manual Geraeteaustausch lA en 20 17 8 Cluster Controller System SMA Solar Technology AG Replacing the Cluster Controller in the Sunny Portal System Carry out the following steps only if you are using Sunny Portal Procedure 1 Determine the PV system identifier of the existing Sunny Portal system of the Cluster Controller Log into Sunny Portal and call up the Sunny Portal system Select Configuration gt PV System Properties gt PV System Data Copy the PV system identifier from the field PV System Identifier into the clipboard 2 Adjust the Sunny Portal settings in the new Cluster Controller Log into the user interface of the Cluster Controller Select the Cluster Controller in the system tree Select Settings gt Sunny Portal Select Edit In the User settings area paste the PV system identifier from the clipboard into the field ID of PV system In the User settings area enter the e mail address in the E mail field that was used for registering the existing Sunny Portal system in Sunny Portal In the User settings area enter the name of the
23. e new inverter is displayed e In the row of the new inverter select 2 and follow the instructions of the configuration wizard Installation Manual Geraeteaustausch lA en 20 13 7 System with Micro Inverters and Sunny Multigate SMA Solar Technology AG 7 3 Replacing the Sunny Multigate in Sunny Portal Requirement LI The PIC and RID of the new Sunny Multigate must be available see type label or label supplied with the Sunny Multigate Procedure 1 O 0 N Os 0 14 Decommission the Sunny Multigate to be replaced see the Sunny Multigate installation manual 2 3 Commission the new Sunny Multigate see the Sunny Multigate installation manual Connect the new Sunny Multigate to the router network switch with Internet connection see the Sunny Multigate installation manual Go to www SunnyPortal com Register MI The PV System Setup Assistant opens Select Next and activate the option am already registered in Sunny Portal Enter the login data of the Sunny Portal system and select Next Select the option Add or replace devices Select Z in the system row in which you wish to replace the Sunny Multigate Enter the PIC and RID of the new Sunny Multigate in the PIC and RID fields Select Identify Select Next MI The page Replace devices opens In the row for the Sunny Multigate to be replaced select the new Sunny Multigate in the drop down list Replace with
24. e the BLUETOOTH interface manual 6 For a new inverter set the NetlD of the system e For inverters with integrated BLUETOOTH turn the rotary switch NetID on the inverter using a screwdriver blade width 2 5 mm to the NetID of the system see the inverter manual For inverters with retrofitted BLUETOOTH interface turn the rotary switch NetID on the inverter using a screwdriver blade width 2 5 mm to the NetID of the system see the interface manual 7 Commission the new inverter see inverter manual 8 Log into the user interface of the Sunny WebBox with BLUETOOTH M The Sunny WebBox with BLUETOOTH automatically detects the new inverter The new inverter is displayed with a padlock symbol in the system tree Installation Manual Geraeteaustausch lA en 20 19 9 System with Sunny WebBox with BLUETOOTH SMA Solar Technology AG 9 Adapt the system password to the device password of the new inverter so that you can access the new inverter e In the Sunny WebBox with BLUETOOTH user interface select the Sunny WebBox with BLUETOOTH in the system tree Select Settings gt User rights gt Edit n the Access control area enter the passwords set up in the inverter for the respective user group standard password for User 0000 standard password for Installer 1111 Select Save The saving process may take a few minutes e Restart the Sunny WebBox with BLUETOOTH via the user interface Select the Sunny WebBox with BL
25. ed with Sunny Explorer yet create a new Speedwire system in Sunny Explorer see the Sunny Explorer help 5 Log into Sunny Explorer at the Speedwire system MI The new inverter is displayed without a padlock symbol in the system tree The new inverter is displayed with a padlock symbol in the system tree A password other than 1111 or other than the system password of the existing system is set for the new inverter Set the system password of the existing system for the new inverter see Sunny Explorer help on the subject of system password 6 In order to transfer the data of the inverter to be replaced to the new inverter n Sunny Explorer select the inverter to be replaced in the system tree e Select M The dialog box Device Replacement opens e Select the new inverter in the Replaceable devices list and select Replace MI The removed inverter is deleted in the Sunny Multigate and the inverter data is transferred to the new inverter 7 In order to NOT transfer the data of the inverter to be replaced to the new inverter select the inverter to be deleted in the Sunny Explorer system tree and then select and confirm the security prompt 8 Replace the micro inverter in the Sunny Portal system e Log into Sunny Portal and call up the Sunny Portal system e Select Configuration gt Device Overview gt Overview of New Devices Select Refresh devices Your system is then searched for new devices MI After about one minute th
26. en set up for the BLUETOOTH system to which you wish to add the new inverter Select Save The saving process may take a few minutes Log into Sunny Explorer at the BLUETOOTH system to which you wish to add the new inverter MI The new inverter is displayed without a padlock symbol in the system tree Set the the noted energy yield of the inverter to be replaced in the new inverter e n Sunny Explorer select the new inverter in the system tree Select Settings gt AC side gt Edit Enter the noted energy yield of the inverter to be replaced in the field Set total yield and then select Save The saving process may take a few minutes Geraeteaustausch lA en 20 Installation Manual SMA Solar Technology AG 12 Appendix 12 Appendix The sections in the appendix must only be observed if they are referenced in the other sections 12 1 Changing the System Password in a Sunny Home Manager System in Sunny Portal This section describes how the system password for a Sunny Home Manager system in Sunny Portal can be changed Requirement LI You must have the user role Installer or Administrator for the Sunny Portal system Procedure 1 Log into Sunny Portal and call up the Sunny Home Manager system 2 Select Configuration gt Device Overview 3 In the Sunny Home Manager row select 1 in the Properties column 4 Select Edit MI The menu for setting the device properties opens 5 Enter the requested password
27. entered in the field Status 6 To call up the data of the SMA Energy Meter select the tab Realtime values gt AC side gt Grid measurements Installation Manual Geraeteaustausch lA en 20 27 1 2 Appendix SMA Solar Technology AG Replacing an SMA Energy Meter in a System with a Sunny Island Inverter 1 1 Write down the serial number indicated on the type label of the new SMA Energy Meter 2 Disassemble the SMA Energy Meter to be replaced see the SMA Energy Meter manual 3 Mount the new SMA Energy Meter and commission it see the SMA Energy Meter manual 4 Transfer the serial number of the new SMA Energy Meter to the inverter using Sunny Explorer e Log into the Speedwire system in Sunny Explorer and select the system in the system tree e If you are using the SMA Energy Meter as purchased electricity meter and feed in meter proceed as follows Select Settings gt AC side gt Edit Enter the serial number of the new SMA Energy Meter in the Measuring interface 1 area in the field Serial number and then select Save The saving process may take a few minutes e If you are using the SMA Energy Meter as PV production meter proceed as follows Select Settings gt AC side gt Edit Enter the serial number of the new SMA Energy Meter in the Measuring interface 2 area in the field Serial number and then select Save The saving process may take a few minutes 2 3 Replacing the Battery Pack Smart Energy A DANG
28. existing Sunny Portal system in the field Name of PV system In the Basic settings area select Yes in the drop down list Use Sunny Portal Select Save 3 Register the new Cluster Controller in Sunny Portal In the Status and actions area select Execute in the field Register M The Cluster Controller synchronizes the system time with the Sunny Portal and carries out the registration OK is displayed in the field Result of the last registration and Sunny Portal sends the access data to the specified e mail address X Has the registration failed e Rectify the error see the Cluster Controller user manual 4 Log into Sunny Portal and call up the Sunny Portal system 5 The Sunny Portal recognizes the new Cluster Controller and opens the configuration wizard automatically To open the configuration wizard manually select Name of your system gt System monitoring gt Set up device now 6 Select in the row of the new Cluster Controller and follow the configuration wizard instructions 8 4 Replacing the Battery Pack Smart Energy See Section 12 3 page 28 18 Geraeteaustausch lA en 20 Installation Manual SMA Solar Technology AG 9 System with Sunny WebBox with BLUETOOTH 9 System with Sunny WebBox with BLUETOOTH 9 1 Procedure when Replacing Different Devices Procedure See 1 Replacing an Inverter with BLUETOOTH in the Sunny WebBox with Section 9 2 page 19 BLUETOOTH 2 Replacing the Sunny WebBox with BLUE
29. he Cluster Controller e Replacing the Cluster Controller in the Sunny Portal System Replacing the Cluster Controller 1 If the Cluster Controller to be replaced still allows it safe the device configuration of the Cluster Controller Log into the user interface of the Cluster Controller e Select the Cluster Controller in the system tree e Select Update and save gt Device Configuration and Save device configuration If required change the save location and the file name for the save file and select Save M The device configuration is downloaded and saved 2 Commission the new Cluster Controller see the Cluster Controller installation manual 3 Br Dy Tela Danger to life due to electric shock Lethal voltages are present at the connection point of the utility grid e Disconnect the connection point from the utility grid using the separator e g circuit breaker e Remove the three pole plug of the top hat rail power supply unit from terminal X1 of the Cluster Controller e Disassemble the Cluster Controller to be replaced see the Cluster Controller installation manual 4 In case you have saved the device configuration of the Cluster Controller to be replaced transfer the device configuration to the new Cluster Controller Log into the user interface of the Cluster Controller Select the Cluster Controller in the system tree e Select Update and save gt Device Configuration and then select Browse in the field Restor
30. he PV system identifier of the existing Sunny Portal system of the Sunny WebBox e Log into Sunny Portal and call up the existing Sunny Portal system e Select Configuration gt PV System Properties gt PV System Data e Copy the PV system identifier from the field PV System Identifier into the clipboard 14 Make Sunny Portal settings in the new Sunny WebBox Log into the user interface of the Sunny WebBox e Select WebBox gt Settings gt Data transmission Paste the PV system identifier from the clipboard into the field PV System Identifier e Activate Yes in the field Use Sunny Portal e Select Save e Select Logout 15 In Sunny Portal replace the Sunny WebBox in the Sunny Portal system e Log into Sunny Portal and call up the Sunny Portal system e Sunny Portal recognizes the new Sunny WebBox and opens the configuration wizard automatically To open the configuration wizard manually select Name of your system gt System monitoring gt Set up device now e Select in the row of the new Sunny WebBox and follow the configuration wizard instructions 24 Geraeteaustausch lA en 20 Installation Manual SMA Solar Technology AG 11 System with Sunny Explorer 11 System with Sunny Explorer 11 1 Speedwire System with Sunny Explorer 11 1 1 Procedure when Replacing Different Devices Procedure See 1 Replacing the SMA Energy Meter Section 12 2 page 27 2 Replacing an Inverter with Speedwire in Sunny Explorer Section 11 1 3
31. he row of the system whose Sunny Home Manager you want to replace Enter the serial number of the new Sunny Home Manager in the PIC field Enter the registration ID of the new Sunny Home Manager in the RID field Select Identify WI Sunny Portal checks whether the serial number and registration ID correspond to the connected Sunny Home Manager X The PV System Setup Assistant cannot find any Sunny Home Manager with the serial number and registration ID Rectify the error see the Sunny Home Manager user manual Select Next 12 Select Finish Geraeteaustausch lA en 20 Installation Manual SMA Solar Technology AG 7 System with Micro Inverters and Sunny Multigate 7 System with Micro Inverters and Sunny Multigate 7 1 Procedure when Replacing Different Devices Procedure See 1 Replacing a Micro Inverter in Sunny Multigate Section 7 2 page 13 2 Replacing a Sunny Multigate in Sunny Portal Section 7 3 page 14 7 2 Replacing a Micro Inverter in Sunny Multigate 1 Decommission the inverter to be replaced see the inverter manual 2 Read off the serial number of the new inverter off the type label and write it down 3 Install the new inverter and get it ready for operation but do not let it feed in yet see the inverter manual Make sure that the new inverter does NOT feed into the utility grid until you have completed the device replacement process in Sunny Explorer 4 If the system has not been captur
32. ich NetlD has been set on the SMA radio controlled sockets of the system Connect the connector plugs of the energy meters to the Sunny Home Manager see the installation manual of the Sunny Home Manager e Plug the network cable in the network terminal of the Sunny Home Manager see the installation manual of the Sunny Home Manager Connect the voltage supply to the Sunny Home Manager see the installation manual of the Sunny Home Manager M The status LED of the Sunny Home Manager first glows red and then flashes red After approximately two minutes the status LED is intermittently flashing green and orange The Sunny Home Manager is connected to Sunny Portal X The status LED is not intermittently flashing green and orange It is possible that the Sunny Home Manager is not correctly connected to the router e Ensure that the Sunny Home Manager is connected to the router correctly see the installation manual of the Sunny Home Manager Keep the serial number and the registration ID of the new Sunny Home Manager ready The data are indicated on the type label on the back of the Sunny Home Manager or on the cover of the CD supplied Go to www SunnyPortal com Register M The PV System Setup Assistant opens Select Next and activate the option am already registered in Sunny Portal Enter the login data of the Sunny Portal system and select Next Select the option Add or replace devices Select in t
33. in the text field PV System Password 6 Enter the new password again in the text field Repeat password 7 Select Save Wl The Sunny Home Manager changes the password for all devices 12 2 Replacing the SMA Energy Meter by Means of Sunny Explorer Procedure e Replacing an SMA Energy Meter in a System with a Sunny Boy Smart Energy Inverter or e Replacing an SMA Energy Meter in a System with a Sunny Island Inverter Replacing an SMA Energy Meter in a System with a Sunny Boy Smart Energy Inverter 1 Write down the serial number indicated on the type label of the new SMA Energy Meter 2 Disassemble the SMA Energy Meter to be replaced see the SMA Energy Meter manual 3 Mount the new SMA Energy Meter and commission it see the SMA Energy Meter manual 4 Transfer the serial number of the new SMA Energy Meter to the inverter using Sunny Explorer e Log into the Speedwire system in Sunny Explorer and select the system in the system tree Select the tab Settings gt PV system communication gt Meter on Speedwire gt Edit In the field Serial number enter the serial number of the new SMA Energy Meter which is used as purchased electricity meter and feed in meter Select Save The saving process may take a few minutes 5 Ensure that the inverters receive the data of the new SMA Energy Meter e Select the tab Realtime values gt PV system communication gt Measured values gt Meter on Speedwire e Check whether the value OK is
34. mission the new inverter see inverter manual 5 Add the new inverter to the Sunny Portal system e Go to www SunnyPortal com Register M The PV System Setup Assistant opens Select Next and then the option am already registered in Sunny Portal Enter the login data of the Sunny Portal system and select Next e Select the option Add or replace devices In the row for the Sunny Portal system select Enter the PIC and RID of the new inverter Select Identify Select Next and follow the instructions of the PV System Setup Assistant 5 4 Replacing the Battery Pack Smart Energy See Section 12 3 page 28 8 Geraeteaustausch lA en 20 Installation Manual SMA Solar Technology AG 6 Sunny Home Manager System 6 Sunny Home Manager System 6 1 Procedure when Replacing Different Devices Procedure See 1 Replacing the SMA Energy Meter or Other Energy Meters in a Section 6 2 page 9 Sunny Home Manager System 2 Replacing Inverters in the Sunny Home Manager Section 6 3 page 10 3 Replacing the Battery Pack Smart Energy Section 12 3 page 28 4 Replacing the Sunny Home Manager Section 6 5 page 12 6 2 Replacing the SMA Energy Meter or Other Energy Meters in a Sunny Home Manager System During time periods when no energy meter is connected a gap occurs in the diagrams with performance data in Sunny Portal on the Name of my system gt Energy Balance page Procedure 1 If you need to replace
35. n gt Device Overview gt Overview of New Devices Select Refresh devices Your system is then searched for new devices MI After a maximum of one minute the new inverter is displayed X The new inverter is not displayed An error has occurred e Rectify the error see the Sunny Home Manager user manual 6 In the row for the new inverter select M The Sunny Home Manager connects to the new inverter This can take two to eight minutes Page 2 of the configuration wizard opens X Page 2 of the configuration wizard does not open and the error message Connection Failed is displayed A password other than 1111 or other than the system password of the existing system is set for the new inverter e Temporarily change the system password of the existing system to the password of the new inverter see Section 12 1 Changing the System Password in a Sunny Home Manager System in Sunny Portal page 27 7 Follow the instructions of the configuration wizard M The new inverter is displayed at Configuration gt Device Overview 8 If you previously changed the system password to the password of the new inverter reset the old system password see Section 12 1 Changing the System Password in a Sunny Home Manager System in Sunny Portal page 27 10 Geraeteaustausch lA en 20 Installation Manual SMA Solar Technology AG 6 Sunny Home Manager System 6 3 2 Replacing an Inverter with BLUETOOTH 1 Decommission the inverter to be replaced
36. nny Explorer crise o E ENER NEE la alm 25 11 1 1 Procedure when Replacing Different Devices 25 11 152 Replacing the SMA Energy Meter SN SINNER 6010 80453 80 EE e a ES eee 25 11 1 3 Replacing an Inverter with Speedwire in Sunny Explorer 25 11 1 4 Replacing the Battery Pack Smart Energy 26 11 2 BLUETOOTH System with Sunny EE 26 11 2 1 Replacing an Inverter with BLUETOOTH in Sunny Explorer 26 KT 27 12 1 Changing the System Password in a Sunny Home Manager System in Sunny Portal 27 12 2 Replacing the SMA Energy Meter by Means of Sunny Explorer LL 27 12 3 Replacing the Battery Pack SmartEn rgy e ele lella 28 ES Cont id O EA eee A e e re ee 30 4 Geraeteaustausch lA en 20 Installation Manual SMA Solar Technology AG 1 Information on this Document 1 Information on this Document 1 1 Validity This document is valid for the replacement of SMA products in PV systems with SMA communication products SMA communication products are devices and software products that receive store and display data of SMA inverters e g Sunny Home Manager Sunny WebBox SMA Cluster Controller Sunny Explorer This document describes the settings you must make in the devices so that the values of your PV system will be displayed properly even after replacing a device 1 2 Target Group This document is intended for qualified persons The activities described in this document must
37. nt and in the manuals of the products described 3 General Information Only inverters of the same device type and with the same type of communication are replaceable In the communication products you can only replace inverters of the same device type which are additionally equipped with the same type of communication BLUETOOTH Speedwire RS485 The device type model is indicated on the type label of the inverter e g model SB 3000TL 21 Do NOT delete inverters in Sunny Portal To retain the data of the inverter to be replaced in Sunny Portal do not delete the inverter to be replaced from Sunny Portal Observe the sequence of the action steps Some of the action steps described in this document must already be performed before decommissioning the device to be replaced and before commissioning the new device Observe the sequence of the action steps Log in at the communication products and Sunny Portal with the user role Installer Log in at the communication products with the user role Installer for replacing devices You will need the password for the user role Installer of the communication product used in the PV system 6 Geraeteaustausch lA en 20 Installation Manual SMA Solar Technology AG 4 Which Section Applies to my System 4 Which Section Applies to my System The replacement of all SMA devices in your PV system is described in the section of the SMA communication product SMA communication product Webconnect
38. nutes Page 2 of the configuration wizard opens X Page 2 of the configuration wizard does not open but the error message Connection failed is displayed A password other than 1111 or other than the system password of the existing system is set for the new inverter Temporarily change the system password of the existing system to the password of the new inverter see Section 12 1 Changing the System Password in a Sunny Home Manager System in Sunny Portal page 27 7 Follow the instructions of the configuration wizard MI The new inverter is displayed at Configuration gt Device Overview 8 If you previously changed the system password to the password of the new inverter reset the old system password see Section 12 1 Changing the System Password in a Sunny Home Manager System in Sunny Portal page 27 6 4 Replacing the Battery Pack Smart Energy See Section 12 3 page 28 Installation Manual Geraeteaustausch lA en 20 11 6 Sunny Home Manager System SMA Solar Technology AG 6 5 Replacing the Sunny Home Manager 1 Oo N A L 12 Decommission the Sunny Home Manager to be replaced see the Sunny Home Manager installation manual Tip Label the plugs or cables of the energy meters with the respective name of the connection of the Sunny Home Manager e g meter 1 DO Commission the new Sunny Home Manager Turn the NetID rotary switch to the NetID of the system using a screwdriver blade width 2 5 mm Tip Check wh
39. nverter to be replaced in the system tree e Select Overview and read off and write down the value in the Total yield row 3 Decommission the inverter to be replaced see the inverter manual 26 lf you retrofit the new inverter with BLUETOOTH communication install the BLUETOOTH interface in the inverter and commission see the BLUETOOTH interface manual For a new inverter set the NetID of the system e For inverters with integrated BLUETOOTH turn the rotary switch NetID on the inverter using a screwdriver blade width 2 5 mm to the NetID of the system see the inverter manual e For inverters with retrofitted BLUETOOTH interface turn the rotary switch NetID on the inverter using a screwdriver blade width 2 5 mm to the NetID of the system see the interface manual Commission the new inverter see inverter manual Log into Sunny Explorer at the BLUETOOTH system MI Sunny Explorer automatically detects the new inverter The new inverter is displayed with a padlock symbol in the system tree Adjust the system passwords of the existing BLUETOOTH system for the new inverter Set up a new BLUETOOTH system in Sunny Explorer and log in as Installer using the password for the user group Installer that has been set up in the new inverter Select the BLUETOOTH system in the system tree Select Settings gt User rights All devices gt Edit Enter the system password for the respective user group that has be
40. ny Explorer and connection to the router in the system System password for user role Installer Geraeteaustausch lA en 20 7 5 Webconnect System in Sunny Portal SMA Solar Technology AG 5 Webconnect System in Sunny Portal 5 1 Procedure when Replacing Different Devices Procedure See 1 Replacing the SMA Energy Meter by Means of Sunny Explorer Section 12 2 page 27 2 Replacing Inverters with Webconnect Communication in Sunny Portal Section 5 3 page 8 3 Replacing the Battery Pack Smart Energy Section 12 3 page 28 5 2 Replacing the SMA Energy Meter by Means of Sunny Explorer See Section 12 2 page 27 5 3 Replacing Inverters with Webconnect Communication in Sunny Portal This section describes the replacement of an inverter with Webconnect communication in Sunny Portal in your Sunny Portal system Thus the new inverter replaces the previous inverter and the data are properly displayed in your Sunny Portal system even after the replacement Procedure 1 Decommission the inverter to be replaced see the inverter manual 2 If you retrofit the new inverter with Speedwire Webconnect communication install the Speedwire Webconnect interface in the inverter and commission see the Speedwire Webconnect interface manual 3 If BLUETOOTH is integrated in the new inverter turn the rotary switch for the NetID with a screwdriver blade width 2 5 mm to O see the inverter manual This deactivates the BLUETOOTH function 4 Com
41. only be performed by qualified persons who have been trained in dealing with the dangers and risks associated with the installation of electrical systems and who have the necessary knowledge to avert danger 1 3 Symbols Symbol Explanation A DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury Indicates a hazardous situation which if not avoided can result in death or serious injury Indicates a hazardous situation which if not avoided can result in minor or moderate injury NOTICE Indicates a situation which if not avoided can result in property damage Information that is important for a specific topic or goal but is not safety relevant Indicates a requirement for meeting a specific goal Desired result ATE A problem that might occur 1 4 Typographies Typography Explanation Example bold e Display texts e The value can be found in the field Energy e Elements on a user interface Select Settings e Terminals e Enter the value 10 in the field Minutes e Elements to be selected e Elements to be entered gt e Connects several elements to be e Select Settings gt Date selected Button Key e Button or key to be selected or e Select Next pressed Installation Manual Geraeteaustausch lA en 20 5 2 Safety SMA Solar Technology AG 2 Safety D Observe the safety information in the manuals Observe all safety information in this docume
42. p the Sunny Portal system e Sunny Portal recognizes the new inverter and opens the configuration wizard automatically To open the configuration wizard manually select Name of your system gt System monitoring gt Set up device now e Select in the row of the new inverter and follow the configuration wizard instructions 16 Geraeteaustausch lA en 20 Installation Manual SMA Solar Technology AG 8 Cluster Controller System 8 3 Replacing the Cluster Controller D No combination of Cluster Controller and Sunny WebBox in one Sunny Portal system possible In a Sunny Portal system the Cluster Controller may not be used in combination with the Sunny WebBox e If there is already a Sunny WebBox in the Sunny Portal system where you want to integrate the new Cluster Controller you must delete the Sunny WebBox from the Sunny Portal system before registering the new Cluster Controller see user manual of the Cluster Controller in Sunny Portal The PV system identifier of the Sunny Portal system can be read off in Sunny Portal under Configuration gt PV System Data and then be inserted in the Cluster Controller as described in this section D Restoring the device configuration of the Cluster Controller observe the firmware version Only configuration files with a firmware version that is the same as or older than that of the new Cluster Controller can be used to restore the device configuration of the Cluster Controller Procedure e Replacing t
43. ry Pack and the return note for the defective Battery Pack in a safe place You will need the return note later to prepare the defective Battery Pack for collection 4 Disconnect the inverter from all voltage sources see the inverter manual at www SMA Solar com 28 Hold the defective Battery Pack by the side handles and slide it to the left of the wall mounting bracket up to the stop This deactivates the lift off protection of the Battery Pack and gives you more room to pull out the cables Remove the data cable from the defective Battery Pack Press the lateral brackets in and pull the plug out of the pin connector Geraeteaustausch lA en 20 Installation Manual SMA Solar Technology AG 12 Appendix 7 Remove the power cable from the defective Battery Pack Turn the plug lock to the left until the plug releases and then pull the plug out of the pin connector 8 If the protective caps of the pin connectors for the data cable and the power cable are available use them to cover the corresponding pin connectors of the defective Battery Pack 9 Insert the data cable and power cable into the bracket on the left hand side of the inverter 10 Remove the defective Battery Pack in an upright position from the wall mounting bracket Mounting the New Battery Pack and Connecting It to the Inverter 1 Remove the new Battery Pack from the packaging and put the packaging aside Be careful when handling the packaging as you will need it la
44. see the inverter manual 2 If you retrofit the new inverter with BLUETOOTH communication install the BLUETOOTH interface in the inverter and commission see the BLUETOOTH interface manual 3 For a new inverter set the NetlD of the system e For inverters with integrated BLUETOOTH turn the rotary switch NetID on the inverter using a screwdriver blade width 2 5 mm to the NetlD of the system see the inverter manual Tip Check which NetlD has been set on the NetlD rotary switch in the connection area e For inverters with retrofitted BLUETOOTH interface turn the rotary switch NetID on the inverter using a screwdriver blade width 2 5 mm to the NetID of the system see the interface manual Tip Check which NetID has been set on the NetlD rotary switch in the connection area 4 Commission the new inverter see inverter manual 5 In Sunny Portal add the new inverter to the Sunny Home Manager system e Log into Sunny Portal and call up the Sunny Home Manager system e Select Configuration gt Device Overview gt Overview of New Devices Select Refresh devices Your system is then searched for new devices MI After a maximum of one minute the new inverter is displayed X The new inverter is not displayed An error has occurred e Rectify the error see the user manual of the Sunny Home Manager 6 In the row for the new inverter select M The Sunny Home Manager connects to the new inverter This can take two to eight mi
45. taller using the new password for the user group Installer that has been set up in the new inverter Select the Speedwire system in the system tree Select Settings gt User rights All devices gt Edit Enter the system password for the respective user group that has been set up for the Speedwire system to which you wish to add the new inverter Select Save The saving process may take a few minutes Log into Sunny Explorer at the Speedwire system to which you wish to add the new inverter M The new inverter is displayed without a padlock symbol in the system tree Set the the noted energy yield of the inverter to be replaced in the new inverter e n Sunny Explorer select the new inverter in the system tree Select Settings gt AC side gt Edit e Enter the noted energy yield of the inverter to be replaced in the field Set total yield and then select Save The saving process may take a few minutes Installation Manual Geraeteaustausch lA en 20 25 11 System with Sunny Explorer SMA Solar Technology AG 11 1 4 Replacing the Battery Pack Smart Energy See Section 12 3 page 28 11 2 BLUETOOTH System with Sunny Explorer 11 l 2 2 1 Replacing an Inverter with BLUETOOTH in Sunny Explorer Read the serial number of the inverter to be replaced off the type label and write it down Determine the energy yield of the inverter to be replaced e Log into Sunny Explorer at the BLUETOOTH system e Select the i
46. ter for packing the defective Battery Pack 2 Hang the new Battery Pack to the left of the inverter in the wall mounting bracket The right hand side of the Battery Pack must be flush with the hook in position marked on the wall mounting bracket 3 Remove the protective caps from the pin connectors for the data cable and power cable and retain them for possible decommissioning 4 If the protective caps of the defective Battery Pack are no longer available place the protective caps of the new Battery Pack onto the pin connectors of the defective Battery Pack 5 Release the data cable and the power cable from the bracket on the inverter 6 Insert the power cable plug in the pin connector for the power cable Insert the plug into the pin connector and turn the lock to the right until the plug snaps into place 7 Ensure that the plug is securely in place 8 Connect the data cable for communication between the inverter and the Battery Pack to the D sub plug of the Battery Pack 9 The plug snaps audibly into place Danger of crushing if the Battery Pack is jolted e Grip the Battery Pack by the handles and carefully push it to the right as far as it will go 11 Position the protective cover over the Battery Pack The brackets on the righthand side of the protective cover must engage with the guides on the left of the inverter enclosure Then press the left side of the protective cover down onto the Battery Pack until it snaps into plac
47. with BLUETOOTH see help of the Sunny WebBox Assistant or quick reference guide on the commissioning of the Sunny WebBox with BLUETOOTH 4 Select Next M The Sunny WebBox search is starting The new Sunny WebBox with BLUETOOTH is displayed Select the new Sunny WebBox with BLUETOOTH and select Configure the WebBox Log in with the user group Installer and the associated password Select Next Activate the option Replace Sunny WebBox Select Next and follow the Sunny WebBox Assistant instructions Determine the PV system identifier of the existing Sunny Portal system with Sunny WebBox with BLUETOOTH O 0 ON A 0 e Log into Sunny Portal and call up the Sunny Portal system Select Configuration gt PV System Properties gt PV System Data e Copy the PV system identifier from the field PV System Identifier into the clipboard 11 Configure the Sunny Portal settings in the new Sunny WebBox with BLUETOOTH e Log into the user interface of the Sunny WebBox with BLUETOOTH e Select Settings gt Sunny Portal gt Next Paste the PV system identifier from the clipboard into the field PV System Identifier e Select the entry Yes in the drop down list Use Sunny Portal e Select Save e Select Logout in the toolbar 12 In Sunny Portal replace the Sunny WebBox with BLUETOOTH in the Sunny Portal system e Log into Sunny Portal and call up the Sunny Portal system The Sunny Portal recognizes the new Sunny WebBox with BL
48. your system gt System monitoring gt Set up device now Select Zin the row of the new inverter and follow the configuration wizard instructions 10 3 Replacing the Sunny WebBox Requirement LI The software Sunny WebBox Assistant must be installed on the computer available free of charge at www SMA Solar com Procedure e If you are using Sunny Portal and if the Sunny WebBox to be replaced still allows it transfer the data saved to the Sunny WebBox to Sunny Portal before replacing the Sunny WebBox Log into the user interface of the Sunny WebBox e Select WebBox gt Info Select Upload in the Last portal upload row M The value Sunny Portal buffer load is 0 5 Decommission the Sunny WebBox to be replaced see Sunny WebBox installation manual 6 Start the Sunny WebBox Assistant on the computer and connect the Sunny WebBox as described if necessary see help of the Sunny WebBox Assistant or quick reference guide on commissioning the Sunny WebBox 7 Select Next M The Sunny WebBox search is starting The new Sunny WebBox is displayed 8 Select the new Sunny WebBox and select Configure the WebBox Installation Manual Geraeteaustausch lA en 20 23 10 System with Sunny WebBox SMA Solar Technology AG 9 Log in with the user group Installer and the associated password 10 Select Next 11 Activate the option Replace Sunny WebBox 12 Select Next and follow the Sunny WebBox Assistant instructions 13 Determine t