Home
EUROLITE MD-3030 DMX rotary motor User Manual
Contents
1. Check the device and the power cord from time to time Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord Please consider that damages caused by manual modifications to the device are not subject to warranty Keep away children and amateurs OPERATING DETERMINATIONS This device is a mirrorball motor for turning mirrorballs The maximum load of the installation eyelet must never be exceeded The safety eyelet must never be used for loads This product is only allowed to be operated with an alternating voltage of 230 V 50 Hz and was designed for indoor use only When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables lying around You endanger your own and the safety of others This device must never be operated or stockpiled in sourroundings where splash water rain moisture or fog may harm the device Moisture or very high humidity can reduce the insulation and lead to mortal electrical shocks When using smoke machines make sure that the device is never exposed to the direct smoke jet and is installed in a distance of 0 5 meters between smoke machine and device The room must only be saturated with an amount of smoke that the visibility will always be more than 10 meters The ambient temperature must always be betwee
2. vor der ersten Inbetriebnahme und nach wesentlichen nderungen vor der Wiederinbetriebnahme durch Sachverst ndige gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens alle vier Jahre durch einen Sachverst ndigen im Umfang der Abnahmepr fung gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens einmal j hrlich durch einen Sachkundigen gepr ft werden Befestigung WICHTIG BERKOPFMONTAGE ERFORDERT EIN HOHES MAR AN ERFAHRUNG Dies beinhaltet aber beschr nkt sich nicht allein auf Berechnungen zur Definition der Tragf higkeit verwendetes Installations material und regelm ige Sicherheitsinspektionen des verwendeten Materials und der Spiegelkugel Versuchen Sie niemals die Installation selbst vorzunehmen wenn Sie nicht ber eine solche Qualifikation verf gen sondern beauftragen Sie einen professionellen Installateur Unsachgem e Installationen k nnen zu Verletzungen und oder zur Besch digung von Eigentum f hren Der Installationsort muss so gew hlt werden dass der Motor absolut horizontal an einem festen ersch tterungsfreien schwingungsfreien und feuerfesten Ort befestigt werden kann Mittels Wasserwaage muss berpr ft werden dass der Motor absolut horizontal befestigt wurde und die Motorenachse absolut senkrecht nach unten zeigt Der Motor und die Spiegelkugel m s
3. 3030 Sicherheits Drehmotor ACHTUNG Ger t vor Feuchtigkeit und N sse sch tzen Niemals das Ger t ffnen Alle Personen die mit der Aufstellung Inbetriebnahme Bedienung Wartung und Instandhaltung dieses Ger tes zu tun haben m ssen entsprechend qualifiziert sein diese Bedienungsanleitung genau beachten die Bedienungsanleitung als Teil des Produkts betrachten die Bedienungsanleitung w hrend der Lebensdauer des Produkts behalten die Bedienungsanleitung an jeden nachfolgenden Besitzer oder Benutzer des Produkts weitergeben sich die letzte Version der Anleitung im Internet herunter laden EINF HRUNG Wir freuen uns dass Sie sich f r einen EUROLITE MD 3030 entschieden haben Wenn Sie nachfolgende Hinweise beachten sind wir sicher dass Sie lange Zeit Freude an Ihrem Kauf haben werden Nehmen Sie den Motor aus der Verpackung SICHERHEITSHINWEISE ACHTUNG Seien Sie besonders vorsichtig beim Umgang mit gef hrlicher Netzspannung Bei die ser Spannung k nnen Sie einen lebensgef hrlichen elektrischen Schlag erhalten Dieses Ger t hat das Werk in sicherheitstechnisch einwandfreiem Zustand verlassen Um diesen Zustand zu erhalten und einen gefahrlosen Betrieb sicherzustellen muss der Anwender die Sicherheitshinweise und die Warnvermerke unbedingt beachten die in dieser Bedienungsanleitung enthalten sind Unbedingt lesen Bei Sch den die durch Nichtbeachtung der Anleitung verursacht werden erlischt der
4. GERATEBESCHREIBUNG Features DMX gesteuerter Spiegelkugelmotor Zum Antrieb von Spiegelkugeln bis zu einem max Gesamtgewicht von 40 kg Dies entspricht bei EUROLITE Spiegelkugeln einem Durchmesser von 100 cm Die max Tragf higkeit bezieht sich immer auf das tats chliche Gewicht der Spiegelkugel inkl Spiegelkugelkette Sicherungskette und Befestigungsmaterial Bedienbar im Standalone Modus oder DMX Interface DMX512 Steuerung ber jeden handels blichen DMX Controller m glich belegt 1 Kanal Funktionen Rotationsrichtung Rotationsgeschwindigkeit Master Slave Einstellung ber DIP Schalter 2 Ketten und 4 Schnellverbinder m ssen separat bestellt werden Anschlussfertig ber Netzleitung mit Schutzkontaktstecker F r den professionellen Einsatz z B in Diskotheken und Versammlungsstatten m ssen unbedingt die Bestimmungen der BGV C1 vormals VBG 70 eingehalten werden Der Motor muss immer mit einer zweiten unabh ngigen Aufh ngung installiert werden Vor der ersten Inbetriebnahme muss die Einrichtung durch einen Sachverst ndigen gepr ft werden Sicherheitsmerkmale e Robuste Bauweise mit Stahlgeh use f r lange Laufzeiten e Hohe Stabilit t durch massive Motorachse Mechanische Fallsicherung gegen unbeabsichtigtes L sen der Achse im Inneren des Motors Gepr fte Tragf higkeit mit 12 facher Nennlast Zus tzlicher Aufnahmepunkt zur geforderten Absturzsicherung der Traglast e EUROLITE Sicherheits Drehmoto
5. Garantiean spruch F r daraus resultierende Folgesch den bernimmt der Hersteller keine Haftung Das Ger t darf nicht in Betrieb genommen werden nachdem es von einem kalten in einen warmen Raum gebracht wurde Das dabei entstehende Kondenswasser kann unter Umst nden Ihr Ger t zerst ren Lassen Sie das Ger t solange uneingeschaltet bis es Zimmertemperatur erreicht hat Der Aufbau entspricht der Schutzklasse Der Netzstecker darf nur an eine Schutzkontakt Steckdose angeschlossen werden 3 19 00066238 DOC Version 1 0 Den Netzstecker immer als letztes einstecken Lassen Sie die Netzleitung nicht mit anderen Kabeln in Kontakt kommen Seien Sie vorsichtig beim Umgang mit Netzleitungen und anschl ssen Fassen Sie diese Teile nie mit nassen H nden an Vergewissern Sie sich dass die anzuschlie ende Netzspannung nicht h her ist als auf der R ckseite ange geben Stecken Sie die Netzleitung nur in geeignete Schutzkontaktsteckdosen ein Achten Sie darauf dass die Netzleitung nicht gequetscht oder durch scharfe Kanten besch digt werden kann berpr fen Sie das Ger t und die Netzleitung in regelm igen Abst nden auf Besch digungen Ger t bei Nichtbenutzung und vor jeder Reinigung vom Netz trennen Fassen Sie dazu den Netzstecker an der Griffl che an und ziehen Sie niemals an der Netzleitung Beachten Sie bitte dass Sch den die durch manuelle Ver nderungen an diesem Ger t verursacht werden nicht unter den Garantieans
6. is received or not If the data is received the control LED lights up permanently If there is no data received at the DMX input the control LED will be off This situation can occur if the 3 PIN XLR plug cable with DMX signal from controller is not connected with the input of the device the controller is switched off or defective the cable or connector is defective or the signal wires are not properly connected with the input connector DMX Protocol Rotation direction and speed Channel Value Function Ee 000 000 1 001 127 Decreasing clockwise rotation 128 255 Increasing counter clockwise rotation CLEANING AND MAINTENANCE The operator has to make sure that safety relating and machine technical installations are inspected by an expert after every four years in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are inspected by a skilled person once a year The following points have to be considered during the inspection 1 All screws used for installing the devices or parts of the device have to be tightly connected and must not be corroded 2 There must not be any deformations on housings fixations and installation spots ceiling suspension trussing 3 Mechanically moved parts like axles eyes and others must not show any traces of wearing e g material abrading or damages and must not rotate with unbalances 4 The ele
7. oder eine andere Last angeh ngt werden Nur an dem Schraubkettenglied in der Befestigungs se der Motorenachse darf eine Last angeh ngt werden Sollte aus irgendwelchen Gr nden die Spiegelkugel an der Sicherungskette h ngen dann muss der Motor sofort stillgelegt werden und die Spiegelkugel muss sofort abgeh ngt werden Die gesamte Installation muss dann von einem Sachverst ndigen auf Defekte untersucht werden Achten Sie darauf dass die Rotation der Spiegelkugel nicht durch Dekorationsteile etc abgebremst oder unterbrochen wird Achten Sie darauf dass niemals Seitenkr fte auf die Installation einwirken k nnen Es ist darauf zu achten dass am Montageort die Spiegelkugel nicht durch Luftstr mung en ins Schwingen geraten kann Die Spiegelkugel und der Motor sind absolut schwingungsfrei aufzuh ngen und zu betreiben berpr fen Sie in regelm igen Abst nden ob sich die Aufh ngevorrichtung z B Schl sselringe Sch kel oder Schraubkettenglieder oder Kettenglieder der Kette Verformungen aufweisen In einem solchen Fall h ngen Sie die Spiegelkugel bitte sofort ab DMX512 Ansteuerung Achten Sie darauf dass die Adern der Datenleitung an keiner A Stelle miteinander in Kontakt treten Die Gerate werden ansonsten nicht bzw nicht korrekt funktionieren 7119 00066238 DOC Version 1 0 Beachten Sie dass die Startadresse abhangig vom verwendeten Controller ist Unbedingt Bedienungsanleitung des verwendeten Controllers beac
8. 1 001 127 Abnehmende Rotation im Uhrzeigersinn 128 255 Zunehmende Rotation gegen den Uhrzeigersinn REINIGUNG UND WARTUNG Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens alle vier Jahre durch einen Sachverst ndigen im Umfang der Abnahmepr fung gepr ft werden Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen mindestens einmal j hrlich durch einen Sachkundigen gepr ft werden Dabei muss unter anderem auf folgende Punkte besonders geachtet werden 1 Alle Schrauben mit denen das Ger t oder Ger teteile montiert sind m ssen fest sitzen und d rfen nicht korrodiert sein 2 An Geh use Befestigungen und Montageort Decke Abh ngung Traverse d rfen keine Verformungen sichtbar sein 10 19 00066238 DOC Version 1 0 3 Mechanisch bewegte Teile wie Achsen sen u A d rfen keinerlei Verschlei spuren zeigen z B Materialabrieb oder Besch digungen und d rfen sich nicht unwuchtig drehen 4 Die elektrischen Anschlussleitungen d rfen keinerlei Besch digungen Materialalterung z B por se Leitungen oder Ablagerungen aufweisen Weitere auf den jeweiligen Einsatzort und die Nutzung abgestimmte Vorschriften werden vom sachkundigen Installateur beachtet und Sicherheitsm ngel behoben Wartungs und Servicearbeiten sind ausschlie lich dem autorisierten Fachhandel vorbehalten Sollten einmal Ersatzteile b
9. DMX controlled operation set DIP Switch 10 to ON Use DIP Switches 1 to 9 to set the desired DMX addresses Addressing Each device occupies 1 channel To ensure that the control signals are properly directed to each device the device requires addressing This is to be adjusted for every single device by changing the DIP switches as set out in the table below The starting address is defined as the first channel from which the device will respond to the controller Please make sure that you do not have any overlapping channels in order to control each device correctly and independently from any other fixture on the DMX data link If two three or more devices are addressed similarly they will work similarly Occupation of the DIP switches Setting the DMX x starting address DIP switch no 112 3 415 6 7 8 9 Device number amp channels Starting address 1 2 4 8 16 32 64 128 256 O A Device 1 channel 1 On A Device 2 channel 2 only Device 3 channel 3 ar Dr off i On A Device 4 channel 4 onl uv Device 5 channel 5 a Controlling After having addressed all devices you may now start operating these via your controller Note The modes of DMX 512 data are shown via the DMX indicator 18 19 00066238 DOC Version 1 0 After switching on the device will automatically detect whether DMX 512 data
10. NCE including but not limited to calculating working load limits installation material being used and periodic safety inspection of all installation material and the mirrorball If you lack these qualifications do not attempt the installation yourself but instead use a professional structural rigger Improper installation can result in bodily injury and or damage to property The motor must only be installed in an absolutely horizontal position at a vibration free oscilation free and fire resistant location By using a water level make sure that the motor is installed absolutely horizontally and that the motor axle points exactly to the bottom The motor and the mirrorball have to be installed out of the reach of people If the motor shall be lowered from the ceiling or high joists professional trussing systems have to be used The motor must never be fixed swinging freely in the room Caution Mirrorballs may cause severe injuries when crashing down If you have doubts concerning the safety of a possible installation do NOT install the motor Before attaching the device make sure that the installation area can hold a minimum point load of 10 times the device s load e g maximum load 3 kg point load 30 kg The mirrorball motor must always be installed via all fixation holes Do only use appropriate screws and make sure that the srews are properly connected with the ground The durability of the installation depends very much on t
11. cm for the EUROLITE mirror balls The maximum load always means the mirror ball weight including the mirror ball chain the safety chain and the fixation material e Operable in stand alone mode or via DMX interface e DMX512 control possible via any commercial DMX controller occupies 1 channel Functions Rotation direction Rotation speed Master Slave Programable via DIP switches 2 chains and 4 quick links must be ordered separately Ready for connection via power cord with safety plug For professional use e g in discotheques and in public places the EN DIN 15560 norms have to be considered The motor always has to be installed with a secondary safety attachment Before taking into operation for the first time the installation has to be approved by an expert Safety features e Rugged construction with steel housing for long operation e High stability due to massive motor axle e Mechanic fall safety against axle loosening inside the motor e Approved load with 12 fold testing weight Additional attechment eyelet for secondary attachment of the load e EUROLITE safety rotary motors comply with the safety norm EN 292 and safety regulation BGV C1 Germany Quality management for testing every production charge Besides the motor and the chain you need two attachment chains and four quick links for the installation Overview 1 Mirrorball motor 2 Motor axle 3 Screw on chain link 4 Mirrorball chain 5 Installa
12. ctric power supply cables must not show any damages material fatigue e g porous cables or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed Maintenance and service operations are only to be carried out by authorized dealers Should you need any spare parts please use genuine parts Should you have further questions please contact your dealer TECHNICAL SPECIFICATIONS Power supply 230 V AC 50 Hz Power consumption 16 W Max load WLL 4 fold 120 kg Max load BGV C1 8 fold 60 kg Max load BGV C1 10 fold 50 kg Max load BGV C1 12 fold 40kg Max diameter of mirror ball 100 cm EUROLITE Rotation speed up to 5 RPM Dimensions LxWxH 285 x 235 x 190 mm Weight 6 kg Please note Every information is subject to change without prior notice 04 05 2005 eu rO luc Germany 19 19 00066238 DOC Version 1 0
13. ddndinanddananeadcaadacdedngues dec badnarennene e 15 DMX512 COMIN WEPRIERFRLLEISPEREPFETEIFHEESEPEREEERFENERFSFERESFBRSHEUERTEFBEE FERESUETELESCBEREEEEILUEREESEPEEREFEITURTERFEFEERERFFENFERTSIEEERRERTSREETE 16 Master Slave OD eration IESPPREPERTERFSBESESERERERFEUERENPEREEREFFTEUERFIFPEEEREEEIFETELESSBEREEERETUERESSEBEEREFFEULRUREFLEEERERFEENERESESEEEREERLERBEER 17 Connection with the MAINS ccii cccccdsccccccasnecscaanccnccoaagecschagedesdcnadateddacensdediae added saeadecaanaa cenaaacseced neue een nennen 17 OPERATION irinin inanasan anaeandika aa taaan Anaan amaaa aa aAA danaa aa aaa anaE ea Aaaa iaia 18 Operation via DIP Switches JU aaa aaaea a Aaaa anne iaa aaa aaa aE aed 18 DMX controlled operation iesirea aaaea iaa aaae aaiae aia aaa ia aad iaaa aaia aaa aa 18 Padre SSING sepa a S EEPE EEE E a E sacends ea HE pect ead ak 18 DMX PrototOl coiii a e e cc Sand vad Saa a aaa aa qusaq s iaa a aeai 19 CLEANING AND MAINTENANCE U U u uuu 19 TECHNICAL SPECIFICATIONS LIU censasseansstisecedvudscondunteesedeuasanacess HE ne a daran 19 Diese Bedienungsanleitung gilt f r die Artikelnummer This user manual is valid for the article number 50301530 Das neueste Update dieser Bedienungsanleitung finden Sie im Internet unter You can find the latest update of this user manual in the Internet under www eurolite de 2 19 00066238 DOC Version 1 0 Deutsch BEDIENUNGSANLEITUNG O euro ce MD
14. ekt und unabh ngig von anderen Ger ten in der DMX Verbindung funktioniert Werden mehrere Ger te auf eine Adresse definiert arbeiten sie synchron 9 19 00066238 DOC Version 1 0 Belegung der DIP Schalter Einstellen der DIP Schalter DMX Startadresse Nr 1 2 3 4 5 6 7 8 9 Ger tenummer amp Kan le Startadresse 1 2 4 8 16 32 64 128256 Ger t 1 Kanal 1 On A Off On A Ger t 2 Kanal 2 on Onl A Ger t 3 Kanal 3 5 m On A Ger t 4 Kanal 4 on V on A A Ger t 5 Kanal 5 er g Ansteuerung Nachdem Sie die Startadresse definiert haben k nnen Sie das Ger t ber Ihren Controller ansteuern Bitte beachten Sie Uber die Kontroll LED DMX des Ger tes werden die Modi DMX 512 Daten angezeigt Schalten Sie das Ger t ein Das Ger t pr ft ob DMX 512 Daten empfangen werden oder nicht Wenn Daten empfangen werden leuchtet die Kontroll LED permanent Werden keine Daten empfangen leuchtet die Kontroll LED nicht Dies ist der Fall wenn kein 3 poliges XLR Kabel DMX Signalkabel vom Controller in die DMX Eingangsbuchse des Ger tes gesteckt wurde wenn der Controller ausgeschaltet oder defekt ist das Kabel oder der Stecker defekt ist oder das Signalkabel nicht richtig eingesteckt ist DMX Protokoll Rotationsrichtung und geschwindigkeit Kanal Wert Funktion BE 000 000 Keine Rotation
15. en tigt werden verwenden Sie bitte nur Originalersatzteile Sollten Sie noch weitere Fragen haben steht Ihnen Ihr Fachh ndler jederzeit gerne zur Verf gung TECHNISCHE DATEN Spannungsversorgung 230 V AC 50 Hz Gesamtanschlusswert 16 W Max Last WLL 4 fach 120 kg Max Last BGV C1 8 fach 60 kg Max Last BGV C1 10 fach 50 kg Max Last BGV C1 12 fach 40 kg Max Spiegelkugeldurchmesser 100 cm EUROLITE Rotationsgeschwindigkeit bis zu 5 U Min Ma e LxBxH 285 x 235 x 190 mm Gewicht 6kg Bitte beachten Sie Technische nderungen ohne vorherige Ank ndigung und Irrtum vorbehalten 04 05 2005 eu rO luc Germany 11 19 00066238 DOC Version 1 0 English USER MANUAL O euro ce MD 3030 Safety Rotary Motor CAUTION Keep this device away from rain and moisture Never open the housing For your own safety please read this user manual carefully before you initial start up Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of the product pass this manual on to every further owner or user of the product download the latest version of the user manual from the Internet INTRODUCTION Thank you for having chosen a EUROLITE MD 3030 If you fo
16. eseeeeeeeseeeeeeeseneeeeeseeeeeseseeeaeeseceaeeseeenaeeesenaaees 9 DMX gesteuerter Betrieb U nn n anan 9 Adressierung des Ger tes nn n aan 9 DNMX Protokoll cee 10 REINIGUNG UND WARTUNG IU aaa terenie teen covers vaccnecunaantevssaadonneeestavdaeedcnetendaavennenccone 10 TECHNISCHE DATEN eiictictscciienndssncsvcnsennnndcenennshsoutnnnd eextasssounnnnsidnbeasnnannentdubetaassnnasnaddsavenanddnonacienensscannonsentecis 11 INTRODUCTION 2 u u L u La iS uh puak amuta aa uu usa asa 12 SAFETY INSTRUCTIONS wii cicccindisetasssoctecensiagennasscnciendiantnnccacnnensisannandeudasessdennniueceviinanasenshnnesnerkthadeedemdoenetetnnenes 12 OPERATING DETERMINATIONS cssiccccssnscanennsecenctentiensnndescnnceatdennannnnwaiesnssnnnnspseravanhssunnnhesnerkihadeetsnioeanictnxee s 13 DESCRIPTION OF THE DEVICE J nenn ea Ba aaa Rn nn saka kisa a na 14 Feat resuusu ma na aaa s aa onan Deep saad ene theese neu Geua sense 24 conto aassasueac a eab aces tenain ee econ SEEN 14 Walety TOAtUIOS DPREECSPPRESERFPRREERLEPRRLLEENERELFELEPPITSTERBEREFTELPEIFTTEEEFEISPERTLERCEERSLERTSORFERESPERRLER BPEREITEERRERSREFEFELESPEFERESEREELT 14 OVENVIGW VEPERPEIERSUBRBENEFETRELSERINGESUEERFEEEESURERESTLURPEITEFENEBEFEEPERTESBESRDEFESPEFBPEETHEBUEEERPEREFTETSERRREBFETEARFSEFBERPEPFEREELTETEBEREEETL NTR 14 INSTALLATION uu u uu uW Du Ain W S A Qullas asss 15 Attachments u u u i cate danataacnus gandsveacecs cas daavan dagdeasce ageta aa gaa
17. euro te BEDIENUNGSANLEITUNG USER MANUAL MD 3030 Safety Rotary Motor MULTI LANGUAGE INSTRUCTIONS Inhaltsverzeichnis Table of contents EINF HRUNGQ sce sews I I I I U u 3 SIGHERHIEITSHINWEISE UU UU a sassa sasahawassankakasssishashawashiasasauakashaasuakanananaatanaska 3 BESTIMMUNGSGEM RE VERWENDUNGTG I I I aa 4 GER ATEBESCHREIBUNGTG I I u 5 Features usus uu aaa dayaaqa usyaq kusaq du iusakuqayayqahalatan adlanan akaqa a a a sah asus ma iaia ph zu aaa 5 Sicherheit rmerkryfale _ u u u uuu kannst san a ara nn qha he han rn suwasqa apk Read 5 LET T 2 1 1 10 01 1121 01 0 BRSDRPEERFERSERESPTSERTREPETHETSERUEELTEUTERFEIREUEETLTEUFFEFSTURRUBELTEFFERTETSENGERLTELTEUSELLEREERTEREEEFTOREBEELTLFUFESLERUBSTERITERLIEN 5 INSTALLATION u aaraa aaao eraa Eaa Eda aAa Aaaa SE aAA EEan aaa Saaana Eana 6 Befestigung ann eine cducdatenedvsdebanetdas 6 DMXS12 Ansleusfunganiuskeineinei een 7 MaStet Slave Be tre iiss ccaalaccaissccec ccavudaraasvadvedavsandanannagdcdasauadsidannddeceavaddutua nad aasan ayaka assaka aswaa aaa dada 8 Anschluss ams Netz iiincccssscicedstaccsresunaieadssadaudesuns ddeaseanduas sauna cada aedasdtanaaa stds vad sagas suadeeaavanasusnnad uapa k aqa apaq a aidaa 8 BEDIENUNG s2 23 4442 002000 aaa anne aeaa araa aa a aa adaa Aaaa aaa ARa seated saaa iaaa i araa 9 Steuerung Uber DIP Schalter U eee eecneeeeeeneeeee
18. he material used at the installation area building material such as wood concrete gas concrete brick etc This is why the fixing material must be chosen to suit the wall material Always ask a specialist for the correct plug screw combination indicating the maximum load and the building material Procedure Step 1 The fixation holes are located on the baseplate Step 2 Hold the baseplate onto the location where the device is to be installed Step 3 Mark the boreholes with a pen or a suitable tool Step 4 Drill the holes Step 5 Hold the baseplate in the desired position and tighten it 15 19 00066238 DOC Version 1 0 The installation material must never include abrading material e g steel cables in order to avoid material wearing The length of the chain must never exceed 100 cm Install the mirrorball chain with the screw on chain link at the installation eyelet of the mirrorball and tighten the fixation screw Insert the fourth chain link of the mirrorball chain with the mirrorball in the screw on chain link and tighten the fixation screw For overhead use always install a safety chain on the mirrorball that can hold at least 12 times the weight of the installation The safety chain must be slightly longer than the mirrorball chain so that the safety chain will always be tension free Pull the safety chain through the safety eyelet of the mirrorball and in the safety eyelet of the motor The maximum drop distance mus
19. hten Die Verbindung zwischen Controller und Ger t sowie zwischen den einzelnen Ger ten sollte mit einem DMxX Kabel erfolgen Die Steckverbindung geht ber 3 polige XLR Stecker und Kupplungen Belegung der XLR Verbindung DMX Ausgang DMX Eingang XLR Einbaubuchse XLR Einbaustecker 1 Masse 1 Masse 2 Signal 2 Signal 3 Signal 3 Signal Wenn Sie Controller mit dieser XLR Belegung verwenden k nnen Sie den DMX Ausgang des Controllers direkt mit dem DMX Eingang des ersten Ger tes der DMX Kette verbinden Sollen DMX Controller mit anderen XLR Ausg ngen angeschlossen werden m ssen Adapterkabel verwendet werden Aufbau einer seriellen DMX Kette Schlie en Sie den DMX Ausgang des ersten Ger tes der Kette an den DMX Eingang des n chsten Ger tes an Verbinden Sie immer einen Ausgang mit dem Eingang des n chsten Ger tes bis alle Ger te ange schlossen sind Achtung Am letzten Ger t muss das DMX Kabel durch einen Abschlusswiderstand abgeschlossen werden Dazu wird ein XLR Stecker in den DMX Ausgang am letzten Ger t gesteckt bei dem zwischen Signal und Signal ein 120 Q Widerstand eingel tet ist Master Slave Betrieb Im Master Slave Betrieb lassen sich mehrere Gerate synchronisieren die dann von einem Mastergerat gesteuert werden An der Ruckseite des Gerates befindet sich eine XLR Einbaubuchse und ein XLR Einbaustecker Uber die sich mehrere Gerate miteinander verbinden lassen W hlen Sie da
20. llow the instructions given in this manual we are sure that you will enjoy this device for a long period of time Unpack your motor SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems If the device has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature 12 19 00066238 DOC Version 1 0 This device falls under protection class The power plug must only be plugged into a protection class outlet Always plug in the power plug last Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged by sharp edges
21. n 5 C and 45 C Keep away from direct insulation particularly in cars and heaters The relative humidity must not exceed 50 with an ambient temperature of 45 C This device must only be operated in an altitude between 20 and 2000 m over NN Never use the device during thunderstorms Over voltage could destroy the device Always disconnect the device during thunderstorms Make sure that the area below the installation place is blocked when rigging derigging or servicing the fixture Operate the device only after having familiarized with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional operation Never use solvents or aggressive detergents in order to clean the device Rather use a soft and damp cloth Please use the original packaging if the device is to be transported Please consider that unauthorized modifications on the device are forbidden due to safety reasons If this device will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock crash etc 13 19 00066238 DOC Version 1 0 DESCRIPTION OF THE DEVICE Features DMX controlled mirrorball motor Suitable for driving mirror balls up to a maximum weight of 40 kg This weight corresponds with a diameter of 100
22. nnection cables is as follows Cable Pin __ International Attention The earth has to be connected If the device will be directly connected with the local power supply network a disconnection switch with a minimum opening of 3 mm at every pole has to be included in the permanent electrical installation The device must only be connected with an electric installation carried out in compliance with the IEC standards The electric installation must be equipped with a Residual Current Device RCD with a maximum fault current of 30 mA DANGER TO LIFE Before taking into operation for the first time the installation has to be approved by an expert 17 19 00066238 DOC Version 1 0 OPERATION The device has two operating modes It can be operated via DIP Switches or it can be run in DMX controlled mode Operation via DIP Switches Manual Mode Rotation Direction and Speed In order to select Manual Mode set DIP switch 10 to OFF Rotation speed can be selected via DIP switch 1 0 5 RPM ON 1 RPM OFF Rotation direction can be selected via DIP switch 2 clockwise OFF counterclockwise ON DIP switches 3 to 9 have no function Master Slave In order to select the Master unit set DIP switch 10 to ON Set DIP switch 10 to OFF on the Slave devices DMX controlled operation You can control the devices individually via your DMX controller Every DMX channel has a different occupation with different features For
23. pruch fallen Kinder und Laien vom Ger t fern halten BESTIMMUNGSGEM RE VERWENDUNG Bei diesem Ger t handelt es sich um einen Drehmotor mit dem sich Spiegelkugeln drehen lassen Die Maximalbelastung der Last se darf dabei niemals berschritten werden Die Sicherungs se darf niemals belastet werden Dieses Produkt ist nur f r den Anschluss an 230 V 50 Hz Wechselspannung zugelassen und wurde aus schlie lich zur Verwendung in Innenr umen konzipiert Achten Sie bei der Wahl des Installationsortes darauf dass das Ger t nicht zu gro er Hitze Feuchtigkeit und Staub ausgesetzt wird Vergewissern Sie sich dass keine Kabel frei herumliegen Sie gef hrden Ihre eigene und die Sicherheit Dritter Das Ger t darf nicht in einer Umgebung eingesetzt oder gelagert werden in der mit Spritzwasser Regen Feuchtigkeit oder Nebel zu rechnen ist Feuchtigkeit oder sehr hohe Luftfeuchtigkeit kann die Isolation reduzieren und zu t dlichen Stromschl gen f hren Beim Einsatz von Nebelger ten ist zu beachten dass das Ger t nie direkt dem Nebelstrahl ausgesetzt ist und mindestens 0 5 m von einem Nebelger t entfernt betrieben wird Der Raum darf nur so stark mit Nebel ges ttigt sein dass eine gute Sichtweite von mindestens 10 m besteht Die Umgebungstemperatur muss zwischen 5 C und 45 C liegen Halten Sie das Ger t von direkter Sonneneinstrahlung auch beim Transport in geschlossenen W gen und Heizk rpern fern Die relative Luftfeuch
24. ren erf llen Sicherheitsnorm EN 292 und Unfallverh tungsvorschrift BGV C1 vormals VBG 70 Qualit tsmanagement zur Pr fung jeder Produktionscharge Zur Installation ben tigen Sie au er dem Motor und der Kugel zwei Anschlagketten und vier Schnellverbindungsglieder Ger te bersicht 1 Spiegelkugelmotor 2 Motorachse 3 Schraubkettenglied 4 Spiegelkugelkette 5 Befestigungs se 6 Spiegelkugel 7 Sicherungs se 8 Sicherungskette 9 Sicherungs se 5 19 00066238 DOC Version 1 0 INSTALLATION und EN 60598 2 17 zu beachten Die Installation darf nur vom autorisierten Fachhan del ausgef hrt werden LEBENSGEFAHR N Bei der Installation sind insbesondere die Bestimmungen der BGV C1 vormals VBG 70 Die Aufh ngevorrichtungen der Spiegelkugel muss so gebaut und bemessen sein dass sie 1 Stunde lang ohne dauernde sch dliche Deformierung das 10 fache der Nutzlast aushalten kann Die Installation muss immer mit einer zweiten unabh ngigen Aufh ngung erfolgen Diese zweite Aufh ngung muss so beschaffen und angebracht sein dass im Fehlerfall der Hauptaufh ngung kein Teil der Installation herabfallen kann W hrend des Auf Um und Abbaus ist der unn tige Aufenthalt im Bereich von Bewegungsfl chen auf Beleuchterbr cken unter hochgelegenen Arbeitspl tzen sowie an sonstigen Gefahrbereichen verboten Der Unternehmer hat daf r zu sorgen dass sicherheitstechnische und maschinentechnische Einrichtungen
25. s Ger t aus das zur Steuerung der Effekte dienen soll Dieses Ger t arbeitet dann als Master Ger t und steuert alle weiteren Slave Ger te die ber ein DMX Kabel mit dem Master Ger t verbunden werden Stecken Sie das DMX Kabel in die OUT Buchse und verbinden Sie es mit dem IN Stecker des n chsten Ger tes Siehe Hinweise unter Bedienung Anschluss ans Netz Schlie en Sie das Ger t ber den Netzstecker ans Netz an Die Belegung der Anschlussleitungen ist wie folgt Leitung Pin international Au enleiter Blau Neutralleiter Gelb Gr n Schutzleiter D Hinweis Der Schutzleiter muss unbedingt angeschlossen werden 8 19 00066238 DOC Version 1 0 Wenn das Ger t direkt an das rtliche Stromnetz angeschlossen wird muss eine Trennvorrichtung mit mindestens 3 mm Kontakt ffnung an jedem Pol in die festverlegte elektrische Installation eingebaut werden Das Ger t darf nur an eine Elektroinstallation angeschlossen werden die den VDE Bestimmungen DIN VDE 0100 entspricht Die Hausinstallation muss mit einem Fehlerstromschutzschalter RCD mit 30 mA Bemessungsdifferenzstrom ausgestattet sein LEBENSGEFAHR Vor der ersten Inbetriebnahme muss die Einrichtung durch einen Sachverst ndigen gepr ft werden BEDIENUNG Das Ger t hat zwei Betriebsarten Es kann entweder ber DIP Schalter oder im DMX gesteuerten Modus betrieben werden Steuerung ber DIP Schalter Manueller Modus Rotationsrichtung und geschwindigkei
26. s installiert werden soll Schritt 3 Markieren Sie Ihre Bohrl cher mit einem Bleistift oder einem geeigneten Werkzeug Schritt 4 Bohren Sie die L cher Schritt 5 Halten Sie das Ger t mit der Bodenplatte in der gew nschten Position und schrauben Sie es fest Als Aufh ngungsmaterial d rfen niemals scheuernde Materialien wie z B Stahlseile verwendet werden um eine Abn tzung aufgrund der hohen Reibung zu verhindern Die L nge der verwendeten Kette darf niemals 100 cm berschreiten Befestigen Sie die Lastkette mit dem Schraubkettenglied an der Befestigungs se der Spiegelkugel und ziehen Sie die Feststellmutter gut fest H ngen Sie das vierte Glied der Lastkette mit der Spiegelkugel in dem Schraubkettenglied am Motor ein und ziehen Sie die Feststellmutter gut fest Sichern Sie die Spiegelkugel bei berkopfmontage immer mit einer Sicherungskette die mindestens f r das 12 fache Gewicht der Installation ausgelegt ist Die Sicherungskette muss etwas l nger als die verwendete Spiegelkugelkette sein so dass die Sicherungskette immer zugfrei bleibt H ngen Sie die Sicherungskette in der Sicherungs se an der Spiegelkugel und in der Sicherungs se am Motor ein Der maximale Fallabstand darf 20 cm nicht berschreiten Eine Sicherungskette die einmal der Belastung durch Absturz ausgesetzt war oder besch digt ist darf nicht mehr als Sicherungskette eingesetzt werden An der Sicherheits se darf niemals eine Spiegelkugel
27. sen au erhalb des Handbereichs von Personen installiert werden Wenn der Motor von der Decke oder hochliegenden Tr gern etc abgeh ngt werden soll muss immer mit Traversensystemen gearbeitet werden Der Motor darf niemals frei schwingend im Raum befestigt werden Achtung Spiegelkugeln k nnen beim Herabst rzen erhebliche Verletzungen verursachen Wenn Sie Zweifel an der Sicherheit einer m glichen Installationsform haben installieren Sie den Motor NICHT Vergewissern Sie sich vor der Montage dass die Montagefl che mindestens die 10 fache Punktbelastung der Belastbarkeit des Motors aushalten kann z B 3 kg Belastbarkeit 30 kg Punktbelastung Die Festigkeit der Installation h ngt entscheidend von der Befestigungsunterlage Bausubstanz Werkstoff wie z B Holz Beton Gasbeton Mauersteine ab Deshalb muss das Befestigungsmaterial unbedingt auf den jeweiligen Werkstoff abgestimmt werden Erfragen Sie die passende D bel Schraubenkombination von einem Fachmann unter Angabe der max Belastbarkeit und des vorliegenden Werkstoffes Der Motor muss immer ber alle Befestigungsl cher angebracht werden Verwenden Sie geeignete Schrauben und vergewissern Sie sich dass die Schrauben fest mit dem Untergrund verbunden sind 6 19 00066238 DOC Version 1 0 Vorgehensweise Schritt 1 An der Bodenplatte des Ger tes befinden sich die Befestigungsl cher zur Installation Schritt 2 Halten Sie das Ger t mit der Bodenplatte an die Stelle wo e
28. t Um den Manuellen Modus stellen Sie DIP Schalter 10 auf OFF Um die Rotationsgeschwindigkeit einzustellen stellen Sie DIP Schalter 1 auf OFF f r 1 UPM Stellen Sie DIP Schalter 1 auf ON f r 0 5 UPM Um die Rotationsrichtung einzustellen stellen Sie DIP Schalter 2 auf OFF f r Rotation im Uhrzeigersinn Stellen Sie DIP Schalter 2 auf ON f r Rotation gegen den Uhrzeigersinn DIP Schalter 3 bis 9 haben in diesem Modus keine Funktion Master Slave Um den Master Slave Modus einzustellen stellen Sie am Masterger t DIP Schalter 10 auf ON Stellen Sie an den Slaveger ten DIP Schalter 10 auf OFF DMX gesteuerter Betrieb ber Ihren DMX Controller k nnen Sie die einzelnen Ger te individuell ansteuern Dabei hat jeder DMX Kanal eine andere Belegung mit verschiedenen Eigenschaften Stellen Sie f r DMX gesteuerten Betrieb DIP Schalter 10 auf ON Benutzen Sie DIP Schalter 1 bis 9 um die gew nschten DMX Adressen einzugeben Adressierung des Ger tes Jedes Ger t belegt 1 Steuerkanal Damit die Steuersignale richtig an jedes Ger t adressiert werden m ssen die Ger te kodiert werden Die Kodierung muss an jedem Ger t einzeln durchgef hrt werden indem Sie die DIP Schalter entsprechend untenstehender Tabelle einstellen Die Startadresse ist der erste Kanal auf den das Ger t auf Signale vom Controller reagiert Bitte vergewissern Sie sich dass sich die Steuerkan le nicht mit anderen Ger ten berlappen damit das Ger t korr
29. t never exceed 20 cm A safety chain which already held the strain of a crash or which is defective must not be used again There must never hang a mirrorball or other load at the safety eyelet Loads must only be hanged at the quick link of the installation eyelet at the motor axle If a mirrorball hangs for any reason at the safety eyelet the motor must be taken out of operation immediately and the mirrorball must be uninstalled The whole installation has to be checked for defects by an expert Make sure that the rotation of the mirrorball is never slowed down or stopped by decoration material etc Make sure that no side forces can impact on the installation Make sure that the mirrorball cannot be moved by air streams The mirrorball and the motor must be installed and operated absolutely swivel free Please check in regular intervals if the installation material e g key ring shackles or screw on chain links or chain links have been deformed Uninstall the mirrorball immediately in such a case DMX512 control The wires must not come into contact with each other otherwise the devices will not work at all or will not work properly A Please note the starting address depends upon which controller is being used A Only use a DMX cable and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another 16 19 00066238 DOC Version 1 0 Occupation of the XLR connection DMX ou
30. te darf 50 bei einer Umgebungstemperatur von 45 C nicht berschreiten Dieses Ger t darf nur in einer H henlage zwischen 20 und 2000 m ber NN betrieben werden Verwenden Sie das Ger t nicht bei Gewitter berspannung k nnte das Ger t zerst ren Des Ger t bei Gewitter allpolig vom Netz trennen Netzstecker ziehen Achten Sie bei der Montage beim Abbau und bei der Durchf hrung von Servicearbeiten darauf dass der Bereich unterhalb des Montageortes abgesperrt ist Nehmen Sie das Ger t erst in Betrieb nachdem Sie sich mit seinen Funktionen vertraut gemacht haben Lassen Sie das Ger t nicht von Personen bedienen die sich nicht mit dem Ger t auskennen Wenn Ger te nicht mehr korrekt funktionieren ist das meist das Ergebnis von unsachgem er Bedienung Reinigen Sie das Ger t niemals mit L sungsmitteln oder scharfen Reinigungsmitteln sondern verwenden Sie ein weiches und angefeuchtetes Tuch Soll das Ger t transportiert werden verwenden Sie bitte die Originalverpackung um Transportsch den zu vermeiden Beachten Sie bitte dass eigenm chtige Ver nderungen an dem Ger t aus Sicherheitsgr nden verboten sind Wird das Ger t anders verwendet als in dieser Bedienungsanleitung beschrieben kann dies zu Sch den am Produkt f hren und der Garantieanspruch erlischt Au erdem ist jede andere Verwendung mit Gefahren wie z B Kurzschluss Brand elektrischem Schlag Abst rzen verbunden 4 19 00066238 DOC Version 1 0
31. tion eyelet 6 Mirrorball 7 Safety eyelet 8 Safety chain 9 Safety eyelet 14 19 00066238 DOC Version 1 0 INSTALLATION DANGER TO LIFE Please consider the EN 60598 2 17and the respective national norms during the installation The installation must only be carried out by an authorized dealer The installation of the mirrorball has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation The installation must always be secured with a secondary safety attachment This secondary safety attach ment must be constructed in a way that no part of the installation can fall down if the main attachment fails When rigging derigging or servicing the fixture staying in the area below the installation place on bridges under high working places and other endangered areas is forbidden The operator has to make sure that safety relating and machine technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time The operator has to make sure that safety relating and machine technical installations are approved by an expert after every four year in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are approved by a skilled person once a year Attachment IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIE
32. tput DMX input XLR mounting socket XLR mounting plug 1 Ground 1 Ground 2 Signal 2 Signal 3 Signal 3 Signal If you are using controllers with this occupation you can connect the DMX output of the controller directly with the DMX input of the first device in the DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first device in the DMX chain with the DMX input of the next device Always connect one output with the input of the next device until all devices are connected Caution At the last fixture the DMX cable has to be terminated Plug the terminator with a 120 Q resistor between Signal and Signal in the DMX output of the last fixture Master Slave operation The master slave operation enables that several devices can be synchronized and controlled by one master device On the rear panel of the device you can find an XLR jack and an XLR plug which can be used for connecting several devices Choose the device which is to control the effects This device then works as master device and controls all other slave devices which are to be connected to the master device via a DMX cable Connect the OUT jack with the IN plug of the next device Please see further instructions under Operation Connection with the mains Connect the device to the mains with the power plug The occupation of the co