1. Contents 8 2 7 8 2 8 8 2 9 8 2 10 8 2 11 8 2 12 8 2 13 8 2 14 8 2 15 9 10 11 12 12 1 12 1 1 Changing the Layer Order Implementing Multiple Actions At Once Switching an Input to a Window Changing a Window Setup Changing Input Button Properties Changing the Device Details Updating the Firmware Setting the IP Network Parameters Displaying the MV 6 Software Version Number Upgrading the Firmware Technical Specifications Default Communication Parameters Kramer Protocol 3000 Kramer Protocol 3000 Syntax Host Message Format 12 1 1 1 Simple Command 12 1 1 2 Command String 12 1 2 Device Message Format 12 1 2 1 Device Long Response 12 1 3 12 1 4 12 1 5 12 1 6 12 1 7 12 2 12 2 1 12 2 2 12 2 3 Command Terms Entering Commands Command Forms Chaining Commands Maximum String Length Kramer Protocol 3000 Commands Common Commands Network Setting Commands Device Specific Commands Figures Figure 1 MV 6 3G HD SDI Multiviewer Front Panel Figure 2 MV 6 3G HD SDI Multiviewer Rear Panel Figure 3 Connecting the MV 6 3G HD SDI Multiviewer Figure 4 Local Area Connection Properties Window Figure 5 Internet Protocol TCP IP Properties Window Figure 6 MV 6 Controller Software Main Window Figure 7 Quick Access Toolbar Figure 8 Connect Window Figure 9 Windows Position Figure 10 Switch Buttons Figure 11 Layer Order Figure 12 Switching an Input to a Window Figure 13 Windo
2. Parameter Description Values Select window Selects the window to adjust A B C D E F Default F Visibility Makes the selected window visible or non visible Visible Non Visible Default Visible Select layer Selects a source to display in the selected window TOP 2 3 4 5 6 Default TOP Input Selects an input 1 2 3 4 5 6 Default 1 Size size Sets the horizontal size for the selected window 1 to 100 Default 66 Ver size Sets the vertical size for the selected window 1 to 100 Default 66 Position Xorigin Sets the X origin for the selected window 0 to 99 Default 0 Y origin Sets the Y origin for the selected window 0 to 99 Default 0 Freeze Freezes or releases the video ON OFF Default OFF 16 KRAMER SIMPLE CREATIVE TECHNOLOGY Operating the MV 6 3G HD SDI Multiviewer Locally 7 9 2 Output Sub menu The parameters in the Output sub menu set the output and LCD preview screen charac teristics Note NTSC or PAL is automatically selected depending on the selected output resolution refresh rate Table 4 Output Sub menu Parameters and Descriptions Parameter Description Values RESOLUTION Sets the output resolution 720p59 94 720p60 720p50 1080p59 94 1080p60 1080p50 Default 720p59 94 GENLOCK MODE Turns on and off and sets the source of the NO GENLOCK INPUT 1 INPUT 2 unlock signal INPUT 3 INPUT 4 INPUT 5 INPUT 6 Default
3. NO GENLOCK BACKGROUND gt Sets the background color using R Gand 000 to 255 B values Default R 21 G 101 B 53 WIN BORDER Turns the window border on or off ON OFF Default ON WIN TEXT Turns the window text labels on and off ON OFF Default ON 7 9 3 Status Sub menu The parameters in the Status sub menu display the input states Table 5 Status Sub menu Parameters and Descriptions Parameter Description Values INPUTS gt Displays the input states IN 1 unlocked IN 2 unlocked IN 3 unlocked IN 4 unlocked IN 5 unlocked IN 6 unlocked GENLOCK unlocked Displays the Genlock state 7 9 4 Comm Settings Sub menu The parameters in the Comm Settings sub menu set the network IP and serial communications values Table 6 Comm Settings Parameters and Descriptions Parameter Description Options NETWORK IP address Sets the IP network address All valid IP addresses Default 192 168 001 039 IP mask Sets the IP network mask All valid subnets Default 255 255 000 000 IP gateway Sets the IP gateway address All valid gateway addresses Default 000 000 000 000 IP port Sets the IP port number All valid TCP ports Default 05000 RS 232 Baud Displays the baud rate 115200 Parity Displays the parity setting none 17 Operating the MV 6 3G HD SDI Multiviewer Locally 7 9 5 User Presets Sub menu The options in the User Presets sub menu save and recall the pr
4. 59 94 60 50 1080p 29 97 30 25 23 98 24 23 98sF 24sF 3G SMPTE 424M SMPTE 296M 1080p 59 94 60 50 MAX INPUT 800mVpp 750 LEVEL OUTPUTS 1 HDMI 1 CV ona BNC connector For 720p 50Hz and 1920p 50Hz the output is PAL For 720p 59 94 60Hz and 1920p 59 94 60Hz the output is NTSC 1 SDI output 75Q on SMPTE 292 SMPTE 296M 720p 59 94 60 50 BNC connector SMPTE 424M SMPTE 296M 1080p 59 94 60 50 MAX OUTPUT LEVEL 800mVpp 750 6 LOOP PREVIEW SCREEN 4 3 TFT color LCD panel SERIAL BIT DATA Up to 2 97Gbps RATE CONTROLS Front panel RS 232 Ethernet POWER Universal 100 240V AC 50 60Hz 35VA CONSUMPTION OPERATING 0 to 40 C 32 to 104 F TEMPERATURE STORAGE 40 to 70 C 40 to 158 F TEMPERATURE HUMIDITY 10 to 90 RHL non condensing DIMENSIONS 19 x 7 4 x 2U W D H rack mountable WEIGHT 3 1kg 6 83165 approx ACCESSORIES Power cord Rack ears 1 Specifications are subject to change without notice 2 The device does not pass audio 30 KRAMER SIMPLE CREATIVE TECHNOLOGY Default Communication Parameters 11 Default Communication Parameters Table 14 Default Communication Parameters RS 232 Protocol 3000 Baud Rate 115200 Data Bits 8 Stop Bits 1 Parity None Command Format ASCII Example Output 1 to Input 2 V 2 gt 1 CRI Ethernet To reset the IP settings to the factory reset values power cycle
5. U1 Button Press to select the first user definable output window pattern programmed using the menu see Section 7 5 13 U2Button Press to select the second user definable output window pattern programmed using the menu see Section 7 5 14 FREEZE Button Press to freeze the selected video window see Section 7 6 15 POSITION Buttons Press either the horizontal H or vertical V button to change the position of the active window see Section 7 3 16 SIZE Buttons Press either the width H or height V button to change the size of the active window see Section 7 9 17 MENU Button Press to move back one level through the menu see Section 7 9 Defining the MV 6 3G HD SDI Multiviewer Figure 2 and Table 2 define the rear panel of the MV 6 3G HD SDI Multiviewer purs OurPurs Loor S0 HOMI 0000 amt IQ OO OO OO OO iO tbe Figure 2 MV 6 3G HD SDI Multiviewer Rear Panel Table 2 MV 6 3G HD SDI Multiviewer Rear Panel Features Feature Function 18 INPUTS 1 to 6 and Associated BNC Connect Inputs to video sources and Loop outputs to loop video acceptors see Section 6 LOOP Outputs 1 to 6 19 RS 2329 pin D sub F Connector Connect to the serial port on a PC or remote controller see Section 6 1 20 Mains Power Fuse Fuse for protecting the device 21 Mains Power Switch Switch for turning the device on or
6. Administrator MODEL Read device model Common mandatory EndUser NAME __ Set machine DNS name NAME Query machine DNS NAME RST Reset machine name to factory Common Administrator default DNS PROT VER Read device protocol version Common mandatory below Weser __ Reset devo Common mandatory 5 Reed device serialnumber Common mandatory End User UPGRADE _ Exeoute mare upgrade Common Administrator venson Reeddewcetimwarewerson Commonmanisoy End User Note The first four presets are geometrical presets only the size and position of the windows are affected but presets five and six include additional information 34 KRAMER SIMPLE CREATIVE TECHNOLOGY Kramer Protocol 3000 12 2 2 Network Setting Commands Command Abbreviation Description Type Permission 12 2 3 Device Specific Commands Command Description Syntax Response BCKGRND Setbackground BCKGRND R G B lt CR gt BCKGRND R G B result lt CR gt color BCKGRND Getbackground BCKGRND BCKGRND R G B lt CR gt color CRDT Set window size CRDT win_num x0 y0 x1 yi lt CR gt CRDT and position in win_num x0 y0 x1 y1 result lt CR gt pixels CRDT Get window size CRDT win_num lt CR gt win_num x0 y0 x1 y1 lt CR gt and position in pixels ETH PORT Set IP port ETH PORT lt protocol gt lt port_num gt ETH PORT lt protocol
7. b Figure 13 Windows Setup Window From the Connect to Input drop down list select the required input Click the Freeze icon to freeze this window Click the Visibility icon to modify the visibility of this window In the Position fields enter the x and y position for the window In the Size fields enter the width and height for the window Click OK The Window setup is changed Soy UM Je 26 KRAMER SIMPLE CREATIVE TECHNOLOGY Operating the MV 6 3G HD SDI Multiviewer Remotely 8 2 11 Changing Input Button Properties To change the properties of an input button 1 Right click on the relevant input button The Input Properties window appears as shown in Figure 14 Input 1 Properties x Label input 1 Icon l gi 2 DVD Mobile Music T 7 Select icon from file Text overlay 17 Show label as text overlay 7 Make style properties global Text size E S A Text color m Text opacity 39 Background color m Background opacity 0 Alignment Figure 14 Input Button Properties Window 2 In the Label text box enter the required button label The label is limited to 10 characters 3 Select the required icon from the list or click on the Select icon from file button and browse to the required file 4 Modify the Text Overlay properties as required 5 Click OK The input button characteristics are changed 2
8. 2 5 Note Unless the device is in off line mode by pressing the Take button when a change is made on the device for example a different output is selected the change is reflected almost immediately in the main window of the Controller Software Similarly if a change is made in the Controller Software the change is reflected almost immediately on the device 20 KRAMER SIMPLE CREATIVE TECHNOLOGY Operating the MV 6 3G HD SDI Multiviewer Remotely 8 2 1 The Menu Bar The menu bar options are shown in Table 10 Table 10 Menu Bar Options Menu Bar Options Sub Menu Description FILE Open Open an existing configuration Save Save the current configuration Exit Exit the MV 6 Controller software DEVICE Connect Disconnect Connect or disconnect to the device see Section 8 2 3 Press Take to put the device in off line mode Press Take Update Update to implement waiting changes and return the device to on line mode see Section 8 2 5 Firmware Update Update the device firmware see Section 8 2 12 LC ERST DISPLAY Set the screen to display one of the preconfigured Presets configurations 6 Split Quad Full 2 Split Set the output resolution Output Resolution 720P 59 94Hz 720P 50Hz 1080P 60Hz 720P 60Hz 1080P 59 94Hz 1080P 50Hz Unlocks the genlock or sets the source for genlock control Genlock Control Free Run default Input 1 Input 2 Input 3 Input 4 Inpu
9. Multiviewer Front Panel 6 KRAMER SIMPLE CREATIVE TECHNOLOGY Defining the MV 6 3G HD SDI Multiviewer Table 1 MV 6 3G HD SDI Multiviewer Front Panel Features Feature Function 1 LCD Video Preview Screen LCD screen to display the output signal 2 WINDOW Buttons A to F Press to select one of the windows 3 INPUT Buttons 1 to 6 Press to select the active input following selection of an active window using the WINDOW buttons 4 LCD Menu 2 Line x 16 Character During normal operation the Window Input list is displayed During menu operations the Menu parameter values are Window Input or Menu Display displayed see Section 7 9 5 Menu Navigation Buttons Press the up A down V left lt 4 and right gt buttons to navigat the menu parameters or values 6 ENTER Button Press to enter the menu or accept the parameter value 7 PANEL LOCK Button Press and hold to lock the front panel buttons Press and hold again to unlock the buttons see Section 7 7 8 Screen Layout Button Press to display and output all six inputs as per the pattern 6 windows 9 Screen Layout Button FH Press to display and output four selected inputs in a quad pattern 4 windows 10 Screen Layout Button L Press to display and output one selected input as a full screen full screen 11 Screen Layout Button 4 Press to display and output two selected inputs as per the pattern 2 windows 12
10. SN Get serial SN lt device serial number gt lt CR gt number SRC BLANK Set window SRC BLANK win_num enable lt CR gt SRC BLANK win_num enable visibility SRC BLANK enable lt CR gt result CR SRC BLANK enable result CR SRC BLNK Get window SRC BLANK win num CR SRC BLANK win enable lt CR gt visibility SRC BLANK lt CR gt SRC BLANK enable lt CR gt SRC VID Set window input SRC VID win_num in_num lt CR gt SRC VID win_num in_num result lt CR gt SRC VID Get window input SRC VID win_num lt CR gt SRC VID win_num in_num lt CR gt VERSION Get firmware VERSION lt firmware version gt lt CR gt version VID RES Set output input VID RES IN OUT id HSIZE VID RES IN OUT id HSIZE VSIZE resolution VSIZE I P FramRate CR FramRate result CR VID RES Get output input VID RES IN OUT id lt CR gt VID RES IN OUT id HSIZE resolution VSIZE IP FramRate CR WIN Set active WIN win num CR WIN win num result lt CR gt window WIN Get active WIN gt CR gt WIN win_num lt CR gt window WND FRZ Set freeze WND FRZ win_num freeze lt CR gt WND FRZ win num freeze result window CR WND FRZ WND FRZ win num CR WND FRZ win_num freeze lt CR gt window WND LR Set window layer WND LR win_num layer lt CR gt WND LR win num layer result lt CR gt WND LR Get window layer WND LR win lt gt WND LR win
11. support recycling KRAMER SIMPLE CREATIVE TECHNOLOGY Overview 3 4 Accessory to Medical Equipment IEC 60601 1 In the modern medical environment remote access is essential for example to transfer clinical data between doctors and to train to medical students The MV 6 is certified according to the IEC 60601 1 2 Clause 2 1 3 Medical Electrical Equipment Part 1 General Requirements for Emc standard which is required when accessory devices are used at locations where medical personnel and patients are present The MV 6 constitutes an optional component that can be considered necessary and suitable as part of medical equipment or for use as part of a medical system to provide real time simultaneous video feeds to those present at the local medical environment and at remote locations In this environment the MV 6 can be added to the system ONLY if the connecting equipment has been evaluated and meets the IEC 60601 1 2 Emc standards Note that when attaching accessory devices to a digital or analog interface they must comply with the IEC standard for which they are used for medical equipment IEC 60601 1 2 data processing equipment IEC 60950 and electromagnetic compatibility IEC 61000 1 Defining the MV 6 3G HD SDI Multiviewer 4 Defining the MV 6 3G HD SDI Multiviewer Figure 1 and Table 1 define the front panel of the MV 6 3G HD SDI Multiviewer 3G HD SDI Muiltiviewenr Figure 1 MV 6 3G HD SDI
12. the best even better Our 1 000 plus different models now appear in 11 groups that are clearly defined by function Thank you for purchasing the Kramer MV 6 3G HD SDI Multiviewer which is ideal for e Professional broadcasting and production studios e Presentation applications e 3GHD SDI multi viewing for medical equipment The package includes the following items e TheMV 6 3G HD SDI Multiviewer e Power cord e This user manual 2 Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual Go to http www kramerelectronics com to check for up to date user manuals application programs and to check if firmware upgrades are available where appropriate 1 GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters GROUP 11 Sierra Products 2 We recommend that you use only the power cord supplied with this device 3 Download up to date Kramer user manuals from http www kramerelectronics com 1 Getting Started 21 Quick Start The following quick start chart summarizes the basic setup and ope
13. to Factory Defaults To reset the device to the factory defaults 1 Turn the device off 2 Press and hold the Reset button on the rear panel of the device 3 While holding the button depressed turn the device on 4 Hold the button depressed for 10 seconds and release the button The configuration is reset to the factory default Using the Menu The menu is displayed on the character display when the Enter button is pressed After no button activity for about a minute the window input list is displayed but the menu remains open in the background at the same position it was last left in Navigation through the menu is performed as follows Operating the MV 6 3G HD SDI Multiviewer Locally e Enter display the menu or select a parameter value Up A scroll up through the parameter value list e Down scroll down through the parameter value list e Left lt 4 move left in the current field e Right f move right through the current field e Menu Move up one level in the menu hierarchy The main menu comprises six sections e Windows see Section 7 9 1 e Output see Section 7 9 2 e Status see Section 7 9 3 e Comm Settings see Section 7 9 4 e User Presets see Section 7 9 5 e System see Section 7 9 6 7 9 1 Windows Sub menu The parameters in the Windows sub menu set the window inputs and characteristics Table 3 Windows Sub menu Parameters and Descriptions
14. 350m 1150ft for SD signals 140m for 1 5GHz HD signals and 120m 394ft for 3GHz HD signals Multi video output formats HD SDI 292M and 3G HD SDI SMPTE 424M HDMI and composite Front panel color LCD preview screen for real time display of output Kramer re Klocking and equalization on each input rebuilds the digital signal to travel longer distances Flexible control options front panel with menu LCD and on screen displays Ethernet and RS 232 Screen handling buttons freeze size position and four pre programmed and two user definable layouts Medical equipment compliance The MV 6 is housed in a 2U height enclosure and is fed from a 100 240 VAC universal switching power supply The device can be controlled via the front panel buttons and remotely via RS 232 serial commands transmitted by a PC touch screen system or other serial controller Ethernet over a LAN 1 Standard Definition SD means an NTSC or PAL compatible video format consisting of 480 for NTSC or 576 for PAL lines of interlaced video 2 High Definition HD means a video format consisting of 720 active lines of progressive video or 1080 lines of progressive or interlaced video Overview 3 1 Recommendations for Best Performance 3 2 3 3 To achieve the best performance e Use only good quality connection cables we recommend Kramer high performance high resolution cables to avoid interference deterioration in signal quality d
15. 7 Operating the MV 6 3G HD SDI Multiviewer Remotely 8 2 12 Changing the Device Details From this window you can change the device name and its IP communication parameters To change the device details 1 From the Menu bar click on Device The Device Details window appears as shown in Figure 15 Device Details x Unit Info Model MV 6 Unit Version R3 2 7321 Serial Number 22272272 Connectivity Ip Address 192 168 001 039 Set Value Mac Address 45 52 5 37 37 36 Gateway 000 000 000 000 Figure 15 Device Details Window 2 Modify the parameters as required For each modified parameter click Set Value 3 Click Close Note If you modify any of the IP parameters you need to reconnect to the device with the new parameters 8 2 13 Updating the Firmware To update the firmware you must be logged in as Admin To update the firmware 1 Download the latest firmware file from http www kramerelectronics com 2 Click Unit Firmware Update 3 Browse to the firmware file that you downloaded 28 KRAMER SIMPLE CREATIVE TECHNOLOGY Operating the MV 6 3G HD SDI Multiviewer Remotely 4 Click Open The device firmware is loaded Note Do not interrupt the uploading process or the device may be damaged 5 When the process is complete reset the device 8 2 14 Setting the IP Network Parameters To set the IP network parameters you must be logged in as Admin To set the IP network parameter
16. 8 001 039 Port 50000 Default Serial COMT Iv NO USB DEVICES v Refresh Ports Connect Cancel Figure 8 Connect Window 2 Select the required method of connection radio button e For Ethernet enter the IP address and Port number of the device To set the default IP address and Port number press the Default button 22 KRAMER SIMPLE CREATIVE TECHNOLOGY Operating the MV 6 3G HD SDI Multiviewer Remotely e Fora serial connection select the required Com port from the drop down list 3 Click Connect If the connection is successful the main window shown in Figure 6 appears If the connection is not successful a Timeout error message appears 8 2 4 Windows Position The windows can be manually manipulated in size and position in the Window Position area Windows Position Figure 9 Windows Position To change the size of a window e Click hold and drag the required window handle To change the position of a window e Click hold and drag anywhere in the window 23 Operating the MV 6 3G HD SDI Multiviewer Remotely 8 2 5 Switch Buttons The switching configuration can be modified by clicking on the Windows and Inputs buttons Switch Windows Inputs A Label 1 1 K Label 1 Layer 1 Top B Label 2 2 Label 2 3 Label 3 Layer 3 Camera Layer 4 D Label 3 Layer 5 E Label 5 5 MK Label 5 Layer 2 F Label 6 6 Label 6 Layer 6 F
17. ABLE LAW THEN ALL IMPLIED WARRANTIES COVERING THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY TO THIS PRODUCT AS PROVIDED UNDER APPICABLE LAW IF ANY PRODUCT TO WHICH THIS LIMITED WARRANTY APPLIES IS A CONSUMER PRODUCT UNDER THE MAGNUSON MOSS WARRANTY ACT 15 U S C A 2301 ET SEQ OR OTHER APPICABLE LAW THE FOREGOING DISCLAIMER OF IMPLIED WARRANTIES SHALL NOT APPLY TO YOU AND ALL IMPLIED WARRANTIES ON THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR THE PARTICULAR PURPOSE SHALL APPLY AS PROVIDED UNDER APPLICABLE LAW Other Conditions This limited warranty gives you specific legal rights and you may have other rights which vary from country to country or state to state This limited warranty is void if i the label bearing the serial number of this product has been removed or defaced ii the product is not distributed by Kramer Electronics or iii this product is not purchased from an authorized Kramer Electronics reseller If you are unsure whether a reseller is an authorized Kramer Electronics reseller please visit our Web site at www kramerelectronics com or contact a Kramer Electronics office from the list at the end of this document Your rights under this limited warranty are not diminished if you do not complete and return the product registration form or complete and submit the online product registration form Kramer Electronics thanks you for purchasi
18. D SDI Multiviewer Locally 7 2 Adjusting the Size of a Window The horizontal and vertical size of each window can be modified To adjust the size of a window 1 Select the required window by pressing one of the Window buttons The relevant button lights 2 Press either the Size or V Size button to adjust the width or height of the selected window 3 Use the left lt 4 and right buttons to adjust the window width and use the up A and down button V to adjust the window height The size changes in real time 4 Press Menu twice to exit the window size setting 7 3 Adjusting the Position of a Window The horizontal and vertical position of each window can be modified To adjust the position of a window 1 Select the required window by pressing one of the Window buttons The relevant button lights 2 Press either the H Position or V Position button to move the window 3 Use the left lt 4 and right buttons to move the window horizontally and use the up A and down button to move the window vertically The position changes in real time 4 Press Menu twice to exit the window position setting 7 4 Defining and Saving a Custom Window Layout In addition to the four predefined window layouts the MV 6 can store two custom window layouts Once you have defined a custom window layout you can save it for future recall To define and save a custom user defined window layout 1 Using the Size and Position buttons a
19. Kramer Electronics Ltd USER MANUAL Model MV 6 3G HD SDI Multiviewer Contents Contents 1 Introduction 2 Getting Started 2 1 Quick Start 3 Overview 3 1 Recommendations for Best Performance 3 2 Safety Instructions 3 3 Recycling Kramer Products 3 4 Accessory to Medical Equipment IEC 60601 1 4 Defining the MV 6 3G HD SDI Multiviewer 5 Installing the MV 6 3G HD SDI Multiviewer in a Rack 6 Connecting the MV 6 3G HD SDI Multiviewer 6 1 Connecting to the RS 232 Port 6 2 Connecting to the Ethernet Port 6 2 1 Connecting the Ethernet Port Directly to a PC 6 2 2 Connecting the Ethernet Port via a Network Hub 7 Operating the MV 6 3G HD SDI Multiviewer Locally 7 1 Display 7 2 Adjusting the Size of a Window 7 3 Adjusting the Position of Window 7 4 Defining and Saving a Custom Window Layout 7 5 Recalling a Window Layout 7 6 Freezing Releasing a Video Output 7 1 Locking the Front Panel 7 8 Resetting the Device to Factory Defaults 7 9 Using the Menu 7 9 1 Windows Sub menu 7 9 2 Output Sub menu 7 9 3 Status Sub menu 7 94 Comm Settings Sub menu 7 9 5 User Presets Sub menu 7 9 6 System Sub menu 8 Operating the MV 6 3G HD SDI Multiviewer Remotely 8 1 Operating the MV 6 via the RS 232 Serial Port 8 2 MV 6 Controller Software 8 2 1 Menu Bar 8 22 Quick Access Toolbar 8 2 3 Connecting to the Device 8 2 4 Windows Position 8 2 5 Switch Buttons 8 2 6 Connection Status SANS KKH
20. appropriate nameplate ratings for information For example for fuse replacement see the value printed on the product label 5 The machine is earthed grounded in a reliable way and is connected only to an electricity socket with grounding Pay particular attention to situations where electricity is supplied indirectly when the power cord is not plugged directly into the socket in the wall for example when using an extension cable or a power strip and that you use only the power cord that is supplied with the machine to 40 C 32 to 104 F 40 to 70 C 40 to 158 F 10 to 90 RHL non condensing CAUTION To rack mount a machine 1 Attach both ear brackets to the machine To do so remove the screws from each side of the machine 5 on each side and replace those screws through the ear brackets 2 Place the ears of the machine against the rack rails and insert the proper screws not provided through each of the four holes in the rack ears Note n some models the front panel may feature built in rack ears Detachable rack ears can be removed for desktop use Always mount the machine in the rack before you attach any cables or connect the machine to the power f you are using a Kramer rack adapter kit for a machine that is not 19 see the Rack Adapters user manual for installation instructions available from our Web site Connecting the MV 6 3G HD SDI Mu
21. cting the Ethernet port configure your PC as follows 1 Right click the My Network Places icon on your desktop 2 Select Properties 3 Right click Local Area Connection Properties 4 Select Properties The Local Area Connection Properties window appears 5 Select the Internet Protocol TCP IP and click the Properties Button see Figure 4 Local Area Connection 2 Properties General Authentication Advanced Connect using E9 Intel R 82566DC Gigabit Network This connection uses the following items V EM Client for Microsoft Networks dl File and Printer Sharing for Microsoft Networks ABl QoS Packet Scheduler Internet Protocol TCP IP Description Transmission Control Protocol Internet Protocol The default wide area network protocol that provides communication across diverse interconnected networks Show icon in notification area when connected Notify me when this connection has limited or no connectivity Figure 4 Local Area Connection Properties Window 6 Select Use the following IP Address and fill in the details as shown in Figure 5 You can use any IP address in the range 192 168 1 1 to 192 168 1 255 excluding 192 168 1 39 that is provided by your IT department 7 Click OK 1 The default IP address is 192 168 1 39 12 KRAMER SIMPLE CREATIVE TECHNOLOGY Operating the MV 6 3G HD SDI Multiviewer Locally 6 2 2 Internet Protocol TCP IP Properti
22. cting to the Ethernet port on the MV 6 see Section 6 2 The Controller software requires the following Windows XP Vista or Windows 7 e Microsoft Net Framework version 3 5 To install the Controller software download the software and run the setup file After installation running the Controller software for the first time displays a window similar to that shown in Figure 6 1 The free MV 6 Control software can be downloaded from http www kramerelectronics com Operating the MV 6 3G HD SDI Multiviewer Remotely ES Sees gt Windows Position Label 1 MIU 3 M Label 3 4 i Label 4 dd E tr ss Layer Order E 8 p p Figure 6 MV 6 Controller Software Main Window Table 9 MV 6 Controller Software Features Feature Function 1 Menu Bar Operate and configure the device using the Menu Bar options see Section 8 2 1 2 Quick Access Toolbar Operate and configure the device using the quick access toolbar buttons see Section 8 2 2 3 Windows Position Modify window size and position by dragging and dropping individual windows see Section 8 2 4 4 Layer Order Click and drag individual layers to arrange the layer order see Section 8 2 5 5 Status Indicator Indicates whether or not the Controller software is connected to the device see Section 8 2 5 6 Switch Windows Press to select a window see Section 8 2 5 7 Switch Inputs Press to select an inputs see Section 8
23. djust all windows to the required configuration 2 Press and hold either the U1 or U2 Layout button until the button flashes once The window layout is stored in the respective memory 7 5 Recalling a Window Layout You can select any of the four predefined or two custom window layouts using the window layout buttons 14 KRAMER SIMPLE CREATIVE TECHNOLOGY Operating the MV 6 3G HD SDI Multiviewer Locally 7 6 7 7 7 8 7 9 To select a window layout e Press one of the six screen layout buttons The button flashes quickly three times and the window layout is recalled from the memory Freezing Releasing a Video Output To freeze release a video output 1 Select the required window to freeze 2 Press the Freeze button see FREEZE Button The button lights and the output video freezes 3 Press the Freeze button The button no longer lights and the video is no longer frozen Locking the Front Panel Lock the front panel buttons to prevent unwanted key presses from changing the current configuration To lock the front panel e Press and hold the Panel Lock button see PANEL LOCK Button The button lights and the front panel buttons are locked Pressing any button causes the Locked message to display and the Lock button to flash To unlock the front panel e Press and hold the Panel Lock button see PANEL LOCK Button The button no longer lights and the front panel buttons are unlocked Resetting the Device
24. erson authorized by Kramer Electronics to repair the product Ifitis decided that this product should be returned directly to Kramer Electronics this product should be property packed preferably in the original carton for shipping Cartons not bearing a return authorization number will be refused Limitation on Liability THE MAXIMUM LIABILITY OF KRAMER ELECTRONICS UNDER THIS LIMITED WARRANTY SHALL NOT EXCEED THE ACTUAL PURCHASE PRICE PAID FOR THE PRODUCT TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS IS NOT RESPONSIBLE FOR DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION OR UNDER ANY OTHER LEGAL THEORY Some countries districts or states do not allow the exclusion or limitation of relief special incidental consequential or indirect damages or the limitation of liability to specified amounts so the above limitations or exclusions may not apply to you Exclusive Remedy TO THE MAXIMUM EXTENT PERMITTED BY LAW THIS LIMITED WARRANTY AND THE REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES REMEDIES AND CONDITIONS WHETHER ORAL OR WRITTEN EXPRESS OR IMPLIED TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IF KRAMER ELECTRONICS CANNOT LAWFULLY DISCLAIM OR EXCLUDE IMPLIED WARRANTIES UNDER APPLIC
25. es General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 192 168 1 2 Subnet mack 255 255 255 0 Default gateway Use the following DNS server addresses Preferred DNS server Alternate DNS server Figure 5 Internet Protocol TCP IP Properties Window Connecting the Ethernet Port via a Network Hub You can connect the Ethernet port of the MV 6 to the Ethernet port on a network hub or network router via a straight through cable with RJ 45 connectors 7 Operating the MV 6 3G HD SDI Multiviewer Locally 7 1 The MV 6 sports an LCD video preview screen on which the live video output is shown Changes made to the device configuration are reflected immediately on the screen allowing you to monitor the output in real time The MV 6 is operated locally using the front panel buttons Display When the MV 6 is powered on the following is displayed briefly MV6 Multiviewer KRAMER The device then performs a self test If the test is successful the Window Input list is displayed an example of which is shown below WINABCDEF INP 24561 3 During operation if there is no button activity for approximately 60 seconds the display reverts to the Window Input list 13 Operating the MV 6 3G H
26. eset configuration memories see Section 7 4 Table 7 User Presets Parameters and Descriptions Parameter Description Options SAVE Saves the current screen layout as a user USER PRESET 1 USER PRESET 2 defined layout Default USER PRESET 1 LOAD Loads the selected user defined screen layout USER PRESET 1 USER PRESET 2 Default USER PRESET 1 7 9 6 System Sub menu The parameters in the System sub menu display the device versions and set the video screen characteristics Table 8 System Sub menu Parameters and Descriptions Parameter Description Options FIRMWARE The device firmware version FPGA VER The device FPGA version S N The device serial number LCD Back Light AUTO ON Default AUTO Brightness 0 to 100 Default 100 18 KRAMER SIMPLE CREATIVE TECHNOLOGY Operating the MV 6 3G HD SDI Multiviewer Remotely 8 Operating the MV 6 3G HD SDI Multiviewer Remotely 8 1 8 2 The MV 6 can be operated remotely using the Kramer MV 6 Controller software via the e RS 232 serial port see Section 8 1 e Ethernet port see Section 8 2 Operating the MV 6 via the RS 232 Serial Port Kramer offers free control software that allows you to operate the MV 6 remotely via a PC or serial controller using serial commands see Section 12 1 This software can be downloaded from www kramerelectronics com MV 6 Controller Software For details regarding conne
27. gt lt port_num gt lt CR gt result lt CR gt ETH PORT Get IP port ETH PORT lt protocol gt ETH PORT lt protocol gt lt port_num gt lt CR gt FPGA VER Get FPGA FPGA VER lt id gt lt CR gt FPGA VER lt id gt lt expected version ver gt lt actual ver gt GNLCK Set genlcock GNLCK id CR GNLCK id result lt CR gt GNLCK Get genlcock GNLCK id lt CR gt GNLCK id state lt CR gt NTGT Set gateway NTGT lt gateway gt lt CR gt NTGT gateway result lt CR gt address NTGT Get gateway NTGT NTGT gateway CR address OVRBLK Set text overlay 4OVRLBK stage stage_id r g b albha nn OVRLBK stage stage_id r g b background alpha parameters color transparency 35 B Kramer Protocol 3000 Command Description Response OVRBLK Get text overlay OVRLBK stage stage_id nn OVRLBK stage stage_id r g b background alpha parameters color transparency OVRL Set text overlay OVRL stage stage id mode r g b nn OVRL stage stage id mode r g parameters alpha b alpha mode color RGB transparency OVRL Get text overlay OVRL stage stage_id nn OVRL stage stage_id mode r g parameters b alpha mode color RGB transparency OVRLTXT Set overlay text OVRLTXT stage stage id type nn OVRLTXT stage stage id size x y string type size x y string OVRLTXT Get overlay text OVRLTXT stage stage id nn OVRLTXT stage stage id type size x y string
28. he right or left into the required position and release The layer is placed in the required position Implementing Multiple Actions At Once To implement multiple actions at once 1 Press the Take button to put the device in off line mode The button changes to the Update button and the device is in off line mode 2 Perform the required actions such as switching and layer order changes 3 Press the Update button The button changes to the Take button and all changes are implemented Switching an Input to a Window To switch an input to a window 1 Click on the required window button The window is selected and the button changes to a solid color as shown in Figure 12 25 Operating the MV 6 3G HD SDI Multiviewer Remotely Switch Windows Inputs A Label 1 1 Label 1 Layer 1 Top K B Label 2 2 l Label 2 Layer 3 o 3 l Label 3 D Label 3 4 Camera Layer 5 E Label 5 5 Label 5 Layer 2 K F Label B B Label B Layer 6 K Figure 12 Switching an Input to a Window 2 Click on the required Inputs button The input is assigned to the previously selected window and the button changes to a solid color 8 2 10 Changing a Window Setup To change a window setup 1 Right click on the relevant Windows button The Window Setup window appears as shown in Figure 13 Window Setup Connect to Input Label 4 Freeze Visibility Position X 844 Y 245 Size 434 H 230 EUN
29. igure 10 Switch Buttons Table 12 Switch Button Characteristics Description 1 CWindow Window identifier A to F 2 Windows Buttons Ato F Press to select a window to assign to an input see Section 8 2 9 3 Camera The label of the input assigned to this window see Section 8 2 9 4 Layer 4 The layer Top layer to 6 of this window see Section 8 2 7 5 4 Input number 1 to 6 6 Inputs Buttons 1 to 6 Press to select an input to assign to a window see Section 8 2 9 7 Camera Input button label see Section 8 2 9 8 Input icon User assigned icon for this input see Section 8 2 9 8 2 6 Connection Status The connection status can be one of the following states e Online the device is connected and being updated in real time by the software e Online in take mode not updating device the device is connected but changes are only implemented when the Update button is pressed Offline in Take mode 24 KRAMER SIMPLE CREATIVE TECHNOLOGY Operating the MV 6 3G HD SDI Multiviewer Remotely 8 2 7 Changing the Layer Order 8 2 8 8 2 9 You can modify the order in which the windows are arranged The top layer is on the right and the bottom layer on the left In Figure 11 layer A is on top and layer F is at the bottom Layer Order n Figure 11 Layer Order To change the window layer order 1 Click and hold on the layer that you want to move 2 Drag the layer to t
30. l remain compatible with any other product or technology with which the product may be used How Long Does this Coverage Last Seven years as of this printing please check our Web site for the most current and accurate warranty information Whois Covered Only the original purchaser of this product is covered under this limited warranty This limited warranty is not transferable to Subsequent purchasers or owners of this product What Kramer Electronics will do Kramer Electronics will at its sole option provide one of the following three remedies to whatever extent it shall deem necessary to DN proper claim under this limited warranty Elect to repair or facilitate the repair of any defective parts within a reasonable period of time free of any charge for the necessary parts and labor to complete the repair and restore this product to its proper operating condition Kramer Electronics will also pay the shipping costs necessary to return this product once the repair is complete 2 Replace this product with a direct replacement or with a similar product deemed by Kramer Electronics to perform substantially the same function as the original product 3 Issue a refund of the original purchase price less depreciation to be determined based on the age of the product at the time remedy is sought under this limited warranty What Kramer Electronics will not do Under This Limited Warranty If this product is returned to Kramer Electronics or the authorized dea
31. ler from which it was purchased or any other party authorized to repair Kramer Electronics products this product must be insured during shipment with the insurance and shipping charges prepaid by you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installation of this product from or into any installation Kramer Electronics will not be responsible for any costs related to any setting up this product any adjustment of user controls or any programming required for a specific installation of this product How to Obtain a Remedy under this Limited Warranty To obtain a remedy under this limited warranty you must contact either the authorized Kramer Electronics reseller from whom you purchased this product or the Kramer Electronics office nearest you For a list of authorized Kramer Electronics resellers and or Kramer Electronics authorized service providers please visit our web site at www kramerelectronics com or contact the Kramer Electronics office nearest you In order to pursue any remedy under this limited warranty you must possess an original dated receipt as proof of purchase from an authorized Kramer Electronics reseller If this product is returned under this limited warranty a return authorization number obtained from Kramer Electronics will be required You may also be directed to an authorized reseller or a p
32. ltiviewer 6 Connecting the MV 6 3G HD SDI Multiviewer The MV 6 accepts up to six SD HD 3G HD SDI inputs The device outputs a signal which can be any combination of the inputs to the SDI HDMI and composite video connectors as shown in Figure 3 3G HD SDI 3G HD SDI Camera Non linear Editor 3G HD SDI Display Preview 3G HD SDI 3G HD SDI LCD SDI Player Camera Display Figure 3 Connecting the MV 6 3G HD SDI Multiviewer Composite Video Recorder Always switch off the power to each device before connecting it to your MV 6 After connecting your MV 6 connect its power and then switch on the power to each device 10 KRAMER SIMPLE CREATIVE TECHNOLOGY Connecting the MV 6 3G HD SDI Multiviewer 6 1 6 2 6 2 1 To connect the MV 6 3G HD SDI Multiviewer as shown in Figure 3 Connect up to six SDI sources SD HD or 3G HD SDI to the INPUT BNC connectors for example 3G HD SDI cameras to IN 1 and IN 3 and an SDI player to IN 2 2 Connect up to six SDI acceptors SD HD or 3G HD SDI to the INPUT LOOP BNC connectors for example a preview SDI display to IN 1 LOOP and a non linear editor to IN 2 LOOP 3 Connect up to three display acceptors to the OUTPUT connectors for example a 3G HD SDI display to the OUTPUT SDI BNC connector an LCD display to the HDMI connector and a CV video recorder to the OUTPUT CV BNC connector 4 Optional Connect a PC and or se
33. ng a Kramer Electronics product We hope it will give you years of satisfaction For the latest information on our products and a list of Kramer distributors visit www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feedback Caution Safety Warning Disconnect the device from the power supply before opening servicing P N 2900 000737 Rev 6 Kramer Electronics Ltd Web site www kramerelectronics com E mail info kramerel com P N 2900 000737 REV 6
34. num layer lt CR gt 36 KRAMER SIMPLE CREATIVE TECHNOLOGY LIMITED WARRANTY The warranty obligations of Kramer Electronics for this product are limited to the terms set forth below Whatis Covered This limited warranty covers defects in materials and workmanship in this product What is Not Covered This limited warranty does not cover any damage deterioration or malfunction resulting from any alteration modification improper or unreasonable use or maintenance misuse abuse accident neglect exposure to excess moisture fire improper packing and shipping such claims must be presented to the carrier lightning power surges or other acts of nature This limited warranty does not cover any damage deterioration or malfunction resulting from the installation or removal of this product from any installation any unauthorized tampering with this product any repairs attempted by anyone unauthorized by Kramer Electronics to make such repairs or any other cause which does not relate directly to a defect in materials and or workmanship of this product This limited warranty does not cover cartons equipment enclosures cables or accessories used in conjunction with this product Without limiting any other exclusion herein Kramer Electronics does not warrant that the product covered hereby including without limitation the technology and or integrated circuit s included in the product will not become obsolete or that such items are or wil
35. off 22 SDI BNC Connector Connect to an SDI video acceptor see Section 7 9 23 OUTPUTS HDMI Connector Connect to an HDMI video acceptor 24 CV BNC Connector Connect to a composite video acceptor 25 ETHERNET RJ 45 Connector Connect to a PC via a LAN for remote control see Section 6 2 26 RESET Button Press and hold while power cycling the device to reset to factory default configuration see Section 7 8 27 Mains Power Connector Connect to the mains power KRAMER SIMPLE CREATIVE TECHNOLOGY Installing the MV 6 3G HD SDI Multiviewer in a Rack 5 Installing the MV 6 3G HD SDI Multiviewer in a Rack This section provides instructions for rack mounting the device Before installing in a rack be sure that the environment is within the recommended range OPERATING TEMPERATURE STORAGE TEMPERATURE HUMIDITY When installing a 19 rack avoid hazards by taking care that 1 It is located within the recommended environmental conditions as the operating ambient temperature of a closed or multi unit rack assembly may exceed the room ambient temperature 2 Once rack mounted enough air will still flow around the machine 3 The machine is placed straight in the correct horizontal position 4 You do not overload the circuit s When connecting the machine to the supply circuit overloading the circuits might have a detrimental effect on overcurrent protection and supply wiring Refer to the
36. ration Step 1 Mount the device see Section 5 Mount the device in a rack or stick the 4 rubber feet to the underside and place the device on a shelf Connect the inputs Connect the loopback outputs Connect the outputs Optional Connect the Ethernet and or RS 232 to a PC for remote control 3G HD SDI Camera Non linear Editor 3G HD SDI Display 3G HD SDI LCD Composite SDI Player Camera Display Video Recorder Step 3 Turn the power on Step 4 Configure the device see Section 7 Configure the device either remotely via RS 232 Ethernet or Horde Ethene locally using the front panel buttons Step 5 Operate the device see Section 7 Operate via the front panel buttons RS 232 and Ethernet 2 KRAMER SIMPLE CREATIVE TECHNOLOGY Overview 3 Overview The MV 6 is a versatile high performance video viewer for signals up to 3G HD SDI The device can window up to six sources in any layout and output the image in SDI HDMI and CV formats Both preprogrammed and customizable screen division is supported In particular the MV 6 features Input bandwidth of up to 3Gbps which supports standard definition high definition and 3G high definition serial digital video signals SD HD 3G HD SDI SMPTE 259M 292M and 424M input compliance and support for data rates of 270Mbps 1483 5Mbps 1485Mbps 2967Mbps and 2970Mbps Input cable equalization up to
37. rial controller to the Ethernet connector see Section 6 2 and or RS 232 see Section 6 1 5 Connect the power cord Connecting to the RS 232 Port You can connect to the MV 6 via an RS 232 connection using for example a PC Note that a null modem adapter connection is not required To connect to the MV 6 via RS 232 e Connect the RS 232 9 pin D sub rear panel port on the MV 6 via a 9 wire straight cable only pin 2 to pin 2 pin 3 to pin 3 and pin 5 to pin 5 need to be connected to the RS 232 9 pin D sub port on your PC Connecting to the Ethernet Port You can connect the MV 6 via the Ethernet port in either of the following Ways e For direct connection to the PC use a crossover cable see Section 6 2 1 e For connection via a network hub or network router use a straight through cable see Section 6 2 2 Connecting the Ethernet Port Directly to a PC You can connect the Ethernet port of the MV 6 to the Ethernet port on your PC via a crossover cable with RJ 45 connectors 1 Switch off the power to each device before connecting it to your MV 6 After connecting your MV 6 switch on its power and then switch on the power to each device 2 Not shown in the illustration Connecting the MV 6 3G HD SDI Multiviewer This type of connection is recommended for identification of the factory default IP address of the MV 6 during the initial configuration After conne
38. s 1 Click Unit gt Device Details 2 Under Connectivity edit the required parameter 3 Click Set Value A confirmation message appears 4 Click OK The parameter is set 5 Reboot the device 8 2 15 Displaying the MV 6 Software Version Number To display the MV 6 Software version number 1 From the Menu bar click About The About MV6 Controller window appears as shown in Figure 16 About MY6 Controller VERSION 1 0 0 7 KRAMER ELECTROHICS Ltd 3 Am Veolamo St Jerusalern Israel 95463 Tel 972 2 6544000 Fax 972 2 6535369 E rnail info kramerel com Web www kramerelectronics com 2011 Kramer Electronics Ltd all rights reserved Figure 16 About MV 6 Window 2 Click OK to close the window 29 Upgrading the Firmware 9 Upgrading the Firmware For instructions on upgrading the firmware see Upgrading the MV 6 Firmware Using the K Upload Software Note To upgrade to firmware V3 2 7321 you must use K Upload software V1 0 0 50 After upgrading perform a factory reset see Section 7 8 10 Technical Specifications Table 13 lists the technical specifications of the MV 6 Table 13 MV 6 Technical Specifications INPUTS 6 SDI serial SD SMPTE 259M SMPTE 125M 480i 59 94 video 750 ITU R 656 5 576i 50 BNC connectors HD SMPTE 292 SMPTE 296M 720p 59 94 60 50 SMPTE 274M 1080i
39. sing a terminal with ASCII communications software such as HyperTerminal Hercules etc Connect the terminal to the serial or Ethernet port on the Kramer device To enter CR press the Enter key ILF is also sent but is ignored by command parser For commands sent from some non Kramer controllers like Crestron some characters require special coding such as X Refer to the controller manual 12 1 5 Command Forms Some commands have short name syntax in addition to long name syntax to allow faster typing The response is always in long syntax 33 Kramer Protocol 3000 12 1 6 Chaining Commands Multiple commands can be chained in the same string Each command is delimited by a pipe character I When chaining commands enter the message starting character and the message closing character only once at the beginning of the string and at the end Commandis in the string do not execute until the closing character is entered A separate response is sent for every command in the chain 12 1 7 Maximum String Length 64 characters 12 2 Kramer Protocol 3000 Commands 12 2 1 Common Commands Command Abbreviation Description Type Permission _ Protocol handshaking Common mandatory BUILD DATE Read device build date Common mandatory configuration HELP Listofcommands Common mandatory EndUser MACHNUM Set Machine number Common
40. t 5 Input 6 Background Color Sets the background color of the window Window Border Turns the window border on and off Refresh Retrieves full information from the device ABOUT Displays the Step in Software and Kramer company details Note Any actions that you are not authorized to perform are grayed out 8 2 2 The Quick Access Toolbar The Quick Access Toolbar buttons are shown in Figure 7 and described in Table 10 SES eee ug Figure 7 Quick Access Toolbar Table 11 Quick Access Toolbar Options Feature Description Open an existing project Save the current project Connect Disconnect m Connects to and disconnects from the device see Section 8 2 3 21 Operating the MV 6 3G HD SDI Multiviewer Remotely Feature Description Press Take to enable multiple off line changes to be made Press Update to implement the changes see Section 8 2 8 Take Update Set the screen to display the 6 window configuration Set the screen to display the 4 window configuration Set the screen to display the single window configuration Set the screen to display the 2 window configuration Freezes the output video Sets the visibility of the active window 8 2 3 Connecting to the Device To connect to the device 1 Click the Connect button The window shown in Figure 8 appears Connection Method Ethernet IP 192 16
41. t CR ILA CR Carriage return ASCII 13 0x0D Line feed ASCII 10 0x0A ISP Space ASCII 32 0x20 12 1 3 Command Terms Command A sequence of ASCII letters A Z a z and Command and parameters must be separated by at least one space 32 KRAMER SIMPLE CREATIVE TECHNOLOGY Kramer Protocol 3000 Parameters A sequence of alphanumeric ASCII characters 0 9 A Z a z and some special characters for specific commands Parameters are separated by commas Message string Every command entered as part of a message string begins with a message starting character and ends with a message closing character Note A string can contain more than one command Commands are separated by a pipe l character Message starting character For host command query For device response Device ID Optional for K NET K NET Device ID followed by Query sign follows some commands to define a query request Message closing character For host messages carriage return ASCII 13 CRLF For device messages carriage return ASCII 13 line feed ASCII 10 Command chain separator character When a message string contains more than one command a pipe I character separates each command Spaces between parameters or command terms are ignored 12 1 4 Entering Commands You can directly enter all commands u
42. the device while holding in the Factory Reset button loc ated on the rear panel of the unit IP Address 192 168 1 39 Subnet mask 255 255 255 0 Default gateway 192 168 1 1 TCP Port 5000 5000 UDP Port 50000 50000 Maximum UDP Ports 10 Maximum TCP Ports 4 31 Kramer Protocol 3000 12 Kramer Protocol 3000 The MV 6 can be operated using serial commands from a PC remote controller or touch screen using the Kramer Protocol 3000 This section describes e Kramer Protocol 3000 syntax see Section 12 1 e Kramer Protocol 3000 commands see Section 12 2 12 1 Kramer Protocol 3000 Syntax 12 1 1 Host Message Format Start Address optional Body Delimiter device_id Message ICR 12 1 1 1 Simple Command Command string with only one command without addressing Start Body Delimiter Command SP Parameter 1 Parameter 2 CR 12 1 1 2 Command String Formal syntax with commands concatenation and addressing Start Address Body Delimiter device_id Command 1 Parameter 1 Parameter1 2 Command 2 Parameter2 1 Parameter2 2 Command 3 Parameter3 1 Parameter3 2 12 1 2 Device Message Format Start Address optional Body delimiter device IcR ILF 12 1 2 1 Device Long Response Echoing command Start Address optional Body Delimiter device id Command 5 Param Param2 resul
43. ue to poor matching and elevated noise levels often associated with low quality cables e Do not secure the cables in tight bundles or roll the slack into tight coils e Avoid interference from neighboring electrical appliances that may adversely influence signal quality and position your Kramer MV 6 away from moisture excessive sunlight and dust This equipment is to be used only inside a building It may only be connected to other equipment that is installed inside a building Safety Instructions Caution There are no operator serviceable parts inside the unit Warning Use only the power cord that is supplied with the unit Warning Do not open the unit High voltages can cause electrical shock Servicing by qualified personnel only Warning Disconnect the power and unplug the unit from the wall before installing Recycling Kramer Products The Waste Electrical and Electronic Equipment WEEE Directive 2002 96 EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility For details of Kramer s recycling arrangements in your particular country go to our recycling pages at http www kramerelectronics com
44. ws Setup Window Figure 14 Input Button Properties Window Figure 15 Device Details Window 25 25 25 26 27 28 28 29 29 30 30 31 32 32 32 32 32 32 32 32 33 33 34 34 34 34 35 35 6 8 10 12 13 20 21 22 23 24 25 26 26 27 28 ii KRAMER SIMPLE CREATIVE TECHNOLOGY Contents Figure 16 About MV 6 Window Tables Table 1 MV 6 3G HD SDI Multiviewer Front Panel Features Table 2 MV 6 3G HD SDI Multiviewer Rear Panel Features Table 3 Windows Sub menu Parameters and Descriptions Table 4 Output Sub menu Parameters and Descriptions Table 5 Status Sub menu Parameters and Descriptions Table 6 Comm Settings Parameters and Descriptions Table 7 User Presets Parameters and Descriptions Table 8 System Sub menu Parameters and Descriptions Table 9 MV 6 Controller Software Features Table 10 Menu Bar Options Table 11 Quick Access Toolbar Options Table 12 Switch Button Characteristics Table 13 MV 6 Technical Specifications Table 14 Default Communication Parameters 29 16 17 17 17 18 18 20 21 24 30 31 iii Introduction 1 Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront the video audio presentation and broadcasting professional on a daily basis In recent years we have redesigned and upgraded most of our line making

Download Pdf Manuals

image

Related Search

Related Contents

HP iPaq RX3100 User's Manual  仕様書等 - 独立行政法人 日本芸術文化振興会  Bedienungsanleitung STA6445D2 - HGW  MANUEL D`UTILISATION  ZyXEL Communications 100 Series Network Router User Manual  Light Cure Orthodontic Bracket Adhesive  Jeep en el Salón Internacional de Ginebra 2015    HP 8/20q User's Manual  GS-2032 Service Manual  